21-10497741k CITY OF Federal Way PERMIT NUMBER _ PERMIT APPLICATION PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325 253-835-2607 + FAX 253-835-2609 + permitcenter@cityoffederalway.com TARGET DATE SITE ADDRESS 2012 S 320TH ST, FEDERAL WAY, WA 98003 SUITE/UNIT # F PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL # $ 10,000 CC-C 0 9 2 1 0 4_ 9 2 9 7 TYPE OF PERMIT X BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT EL PAISANO TAMALES KITCHEN TENANT IMPROVEMENT TO CHANGE USE FROM EXISTING SALON PROJECT DESCRIPTION (ROYALS BARBER SALON) TO COMMERCIAL KITCHEN WITH NO Detailed description of work to 5 be included on this permit only TENANT SPACE IN MIXED USE BUILDING IN CENTER PLAZA. NAME Laura Camarena PRIMARY PHONE 206-972-9554 PROPERTY OWNER MAILING ADDRESS 2012 320th St. E-MAIL lauracamarena22@gmail.com CITY Federal Way STATE ZIP 98003 NAME OMAR CONSTRUCTIOWNASERVICES LLC PHONE 206-353-6898 MAILING ADDRESS 10043 35TH AVE SW E-MAIL womaralvarenga@gmail.com CONTRACTOR CITY SEATTLE SATE WA ZIP 98146 FAX WA STATE CONTRACTOR'S LICENSE # r EXPIRATION DATE UBI # 604 111 086 OMARCCS833JP 04 i 18 i2023 NAME David Lee PRIMARY PHONE 206-817-6081 MAILING ADDRESS 2126 NW 204th St E-MAIL david6081 @gmail.com APPLICANT CITY Shoreline STATE WA ZIP 98177 FAX NAME David Lee PRIMARY PHONE PROJECT CONTACT 206-817-6081 MAILING ADDRESS 2126 NW 204th St E-MAIL david6081 mail.com (The individual t0 reC2LU2 and respond to all correspondence CITY Shoreline STATE WA ZIP 98177 FAX concerning this application) PROJECT FINANCING NAMELaura Camarena ® OWNER -FINANCED When value is $5,000 or more MAILING ADDRESS, CITY, STATE, ZIP PHONE (RCW 19.27.095) SUITE F, 2012 S 320TH ST, FEDERAL WAY, WA 98003 206-972-9554 I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. 11 /29/2021 SIGNATURE: DATE PRINT NAME: David Lee Bulletin #100 — February 19, 2020 Page 1 of 2 k:AHandouts\Permit Application MECHANICAL PERMIT Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existiggfixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS (commercial) BOILERS FURNACES HOT WATER TANKS (Gas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES PLUMBING PERMIT Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. BATHTUBS (or Tub/shower combo) LAVS (Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS (Kitchen/Utility) WATER HEATERS (Electric) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS N/A City of Federal Way City of Federal Way EXISTING/PREVIOUS USE LOT SIZE (In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? Salon (Group B) 260,258 x Yes ❑ No ❑ Yes ❑ No RESIDENTIAL -NEW OR ADDITION AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE ............................................................................................................................... BASEMENT ............................................................................................................................... FIRST FLOOR (or Mobile Home) ............................................................................................................................... SECOND FLOOR ............................................................................................................................... COVERED ENTRY ............................................................................................................................... DECK ............................................................................................................................... GARAGE ❑ CARPORT ❑ ............................................................................................................................... OTHER (describe) ............................................................................................................................... Area Totals EXISTING PROPOSED TOTAL **NEW HOMES ONLY** ESTIMATED SELLING PRICE $ 1 # OF BEDROOMS COMMERCIAL — NEW/ADDITION AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction Type # of Stories Additional Information NEW BUILDING ADDITION COMMERCIAL — REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction Type # of Stories Additional Information TOTAL BUILDING 22,328 Mix Use III-B 1 TENANT AREA ONLY 1,540 B 111-B PROJECT AREA ONLY 1,540 B III-B 1 Bulletin #100 — February 19, 2020 Page 2 of 2 k:\Handouts\Permit Application - �-� .- _ _ 4 1 3.50' - -. �� _. - F- . ... ... ... ... ... ... ... ... ... ... ... .. .................. ................. ................. ............. - - ; -� .-.T.-., .......... _ ........... '******* .... ........... ............ ........... I EXISTING PARKING LOT I I i Q 1. w PROJECT CD I• TENANT = SPACE w z O 4 O 1. z z W �L �L � � i w Q D- Q D- 1- U Qz U z CLI z J w w w W DI � D ❑ I � ❑ Q � w I w I Q C) > < u I N 1 1 1 I I I I SITE PLAN (REFERENCE ONLY) N SCALE: N/A PROPERTY DATA: PROPERTY PARCEL: 092104-9297 PROPERTY ADDRESS: 2012 S 320TH ST, FEDERAL WAY, WA 98003 PROPERTY OWNER: NWCC CENTER PLAZA LLC LOT SIZE: 260,258 SF PROJECT BUILDING: III-B CONSTRUCTION, FULL SPRINKLER, ONE STORY, TOTAL GFA 22,328 SF OCCUPANCY TYPE: EXISTING: B (ROYALS BARBER SALON) PROPOSED: B TENANT SPACE: 1540 SF (LEASING) SUITE F, 2012 S 320TH ST, FEDERAL WAY, WA 98003 TENANT BUSINESS: EL PAISANO TAMALES KITCHEN RESTAURANT OWNER: LAURA CAMARENA 206-972-9554 LEGAL DESCRIPTION: PCL B OF FEDERAL WAY LLA# BLA06-1061 11 -SU REC# 20061229900009 SD LLA BEING LOCATED IN W 112 OF SE 1/4 OF SW 1/4 OF SEC 9-21-4 - TGW UND 1/4 INT IN TR X OF KCSP 1077139 REC #7806301002 LESS POR FOR RD AS PER REC# 20060410002354 PLat Block: Plat Lot: PARKING SPACE ANALYSIS: TENANT SPACE IS ESTABLISHED IN CENTER PLAZA SHOPPING CENTER, PARKING SPACE IS SHARED USE IN SHOPPING CENTER PROVIDED PARKING AREA. SINCE EXISTING TENANT SPACE NOT INCREASE, ADDITIONAL PARKING SHALL NOT BE REQUIRED. Q z 0 N Q w LL- w U Q z z w w 0 5 3 1 GTH 5T Q QPROJECT m 51TE > = u Q LLJ Z N O w 5 320TH 5T VICINITY MAP N (SCALE: N/A ) PROJECT DESCRIPTIONS: TENANT IMPROVEMENT TO CHANGE USE FROM EXISTING SALON (ROYALS BARBER SALON) TO COMMERCIAL KITCHEN WITH NO SEATING (EL PA15ANO TAMALES KITCHEN) IN 1 540 SF (GFA) TENANT SPACE IN MIXED USE BUILDING IN CENTER PLAZA. PROJECT WILL NOT HAVE ANY STRUCTURAL WORK. EXISTING BUILDING FLOOR AREA NO CHANGE. EXISTING BUILDING ENVELOP NO CHANGE. EXISTING CEILING SYSTEM NO CHANGE. EXISTING HVAC AND DUCTING SYSTEM NO CHANGE EXISTING RESTROOMS NO CHANGE DEFERRED SUBMITTAL: PLUMBING, ELECTRICAL, HOOD SYSTEM, STOREFRONT SIGN, AND FIRE ALARM SYSTEM MODIFICATION. CODE COMPLYING: 2016 INTERNATIONAL BUILDING CODE (IBC) 2016 INTERNATIONAL FIRE CODE (IFC) 2016 INTERNATIONAL MECHANICAL CODE (IMC) 2018 INTERNATIONAL FUEL GAS CODE (IFGC) 2018 UNIFORM PLUMBING CODE (UPC) 2018 NATIONAL ELECTRIC CODE (NEC) 2018 WASH I NGTON STATE ENERGY CODE (WSEC) 2009 ICC/ANSI A 1 1 7. 1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES CITY OF FEDERAL WAY ALL CODE AMENDMENTS OCCUPANCY LOAD & PLUMBING FIXTURE CALCULATIONS OCCUPANCY AREA (NET) NET AREA OCCUPANCY LOAD KITCHEN AND SERVICE AREA 1 063 SF 1 083 / 200 = 5.41 BUSINESS AREA I 29G SF 1 29G / 150 = 1.97 1 KESTROOM * HALLWAY 84 SF 1 84 / 100 = 0.64 TOTAL I 1 4G2 SF I 6.22 9 PLUMBING FIXTURE CALCULATION: (WAC CHAPTER 29, Table 2902. 1 ) MEN: 9 / 2 / 75 = O.OG LADY: 9 / 2 / 75 = O.OG REQUIRED: (1) TOILET PER 25 FOR THE FIRST 50, (1) LAVATORY PER 40 FOR THE FIRST 80. PROVIDE: (1) TOILET AND (1) LAVATORY, ADA COMPLIANT (FOR EMPLOYEE USE ONLY) THIS COMMERCIAL KITCHEN WILL NOT HAVE DINING AREA. THE COSTUMER AREA LESS THEN 300 SF. NO PUBLIC KESTKOOM PROVIDED PER IBC 2902.3 EXCEPTION 2. EXISTING RESTROOM FOR EMPLOYEE USE ONLY RECEIVED 12/27/21 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 0 o C") 0 CO a' v �I 00 W 0 cfl p co � r� V � N � q O � q 0 0 rn W Q U � H Q J W � w 0 LL O U) � o N H M • • Cn a N N V w LL W Cn O V4 a REVISIONS w z a w aLu H~ O cn z SHEET Al DATE: 1 1 /23/202 1