21-10497741k
CITY OF
Federal Way
PERMIT NUMBER _
PERMIT APPLICATION
PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325
253-835-2607 + FAX 253-835-2609 + permitcenter@cityoffederalway.com
TARGET DATE
SITE ADDRESS
2012 S 320TH ST, FEDERAL WAY, WA 98003
SUITE/UNIT #
F
PROJECT VALUATION
ZONING
ASSESSOR'S TAX/PARCEL #
$ 10,000
CC-C
0 9 2 1 0 4_ 9 2 9 7
TYPE OF PERMIT
X BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION
NAME OF PROJECT
EL PAISANO TAMALES KITCHEN
TENANT IMPROVEMENT TO CHANGE USE FROM EXISTING SALON
PROJECT DESCRIPTION
(ROYALS BARBER SALON) TO COMMERCIAL KITCHEN WITH NO
Detailed description of work to
5
be included on this permit only
TENANT SPACE IN MIXED USE BUILDING IN CENTER PLAZA.
NAME
Laura Camarena
PRIMARY PHONE
206-972-9554
PROPERTY OWNER
MAILING ADDRESS
2012 320th St.
E-MAIL
lauracamarena22@gmail.com
CITY Federal Way
STATE
ZIP 98003
NAME OMAR CONSTRUCTIOWNASERVICES LLC
PHONE 206-353-6898
MAILING ADDRESS
10043 35TH AVE SW
E-MAIL
womaralvarenga@gmail.com
CONTRACTOR
CITY SEATTLE
SATE WA
ZIP 98146
FAX
WA STATE CONTRACTOR'S LICENSE #
r
EXPIRATION DATE
UBI # 604 111 086
OMARCCS833JP
04 i 18 i2023
NAME
David Lee
PRIMARY PHONE
206-817-6081
MAILING ADDRESS 2126 NW 204th St
E-MAIL
david6081 @gmail.com
APPLICANT
CITY
Shoreline
STATE
WA
ZIP
98177
FAX
NAME David Lee
PRIMARY PHONE
PROJECT CONTACT
206-817-6081
MAILING ADDRESS
2126 NW 204th St
E-MAIL
david6081 mail.com
(The individual t0 reC2LU2 and
respond to all correspondence
CITY Shoreline
STATE
WA
ZIP
98177
FAX
concerning this application)
PROJECT FINANCING
NAMELaura Camarena
® OWNER -FINANCED
When value is $5,000 or more
MAILING ADDRESS, CITY, STATE, ZIP
PHONE
(RCW 19.27.095)
SUITE F, 2012 S 320TH ST, FEDERAL WAY, WA 98003
206-972-9554
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in
the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the city as apart of this application.
11 /29/2021
SIGNATURE: DATE
PRINT NAME: David Lee
Bulletin #100 — February 19, 2020 Page 1 of 2 k:AHandouts\Permit Application
MECHANICAL PERMIT
Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existiggfixtures to remain.
AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe)
AIR CONDITIONER FIREPLACE INSERTS HOODS (commercial)
BOILERS FURNACES HOT WATER TANKS (Gas)
COMPRESSORS GAS LOG SETS REFRIGERATION SYST
DUCTING GAS PIPING WOODSTOVES
PLUMBING PERMIT
Indicate how many of each type offixture
to be installed or relocated as
part of this project. Do not include existing fixtures to remain.
BATHTUBS (or Tub/shower combo)
LAVS (Hand Sinks)
TOILETS WATER PIPING
DISHWASHERS
RAINWATER SYSTEMS
URINALS OTHER (Describe)
DRAINS
SHOWERS
VACUUM BREAKERS
DRINKING FOUNTAINS
SINKS (Kitchen/Utility)
WATER HEATERS (Electric)
HOSE BIBBS
SUMPS
WASHING MACHINES TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY?
WATER PURVEYOR
SEWER PURVEYOR
VALUE OF EXISTING IMPROVEMENTS
N/A
City of Federal Way
City of Federal Way
EXISTING/PREVIOUS USE
LOT SIZE (In Square Feet)
EXISTING FIRE SPRINKLER SYSTEM?
PROPOSED FIRE SUPPRESSION SYSTEM?
Salon (Group B)
260,258
x Yes ❑ No
❑ Yes ❑ No
RESIDENTIAL -NEW OR ADDITION
AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
...............................................................................................................................
BASEMENT
...............................................................................................................................
FIRST FLOOR (or Mobile Home)
...............................................................................................................................
SECOND FLOOR
...............................................................................................................................
COVERED ENTRY
...............................................................................................................................
DECK
...............................................................................................................................
GARAGE ❑ CARPORT ❑
...............................................................................................................................
OTHER (describe)
...............................................................................................................................
Area Totals EXISTING PROPOSED TOTAL
**NEW HOMES ONLY**
ESTIMATED SELLING PRICE $ 1 # OF BEDROOMS
COMMERCIAL — NEW/ADDITION
AREA DESCRIPTION
Area in
Square Feet
Occupancy Group(s)
Construction
Type
# of
Stories
Additional Information
NEW BUILDING
ADDITION
COMMERCIAL — REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION
Area in
Square Feet
Occupancy Group(s)
Construction
Type
# of
Stories
Additional Information
TOTAL BUILDING
22,328
Mix Use
III-B
1
TENANT AREA ONLY
1,540
B
111-B
PROJECT AREA ONLY
1,540
B
III-B
1
Bulletin #100 — February 19, 2020 Page 2 of 2 k:\Handouts\Permit Application
- �-�
.- _
_
4 1 3.50'
- -. �� _. -
F-
. ... ... ... ... ... ... ... ... ... ... ... ..
..................
.................
.................
.............
-
- ;
-� .-.T.-.,
..........
_
...........
'******* ....
...........
............
...........
I
EXISTING PARKING LOT
I
I
i
Q
1.
w
PROJECT
CD
I•
TENANT
=
SPACE
w
z
O
4
O
1.
z
z
W
�L
�L
�
�
i
w
Q
D-
Q
D-
1-
U
Qz
U
z
CLI
z
J
w
w
w
W
DI
�
D
❑
I
�
❑
Q
�
w I
w
I
Q
C)
>
<
u
I
N
1
1
1
I
I
I
I
SITE PLAN
(REFERENCE ONLY)
N SCALE: N/A
PROPERTY DATA:
PROPERTY PARCEL: 092104-9297
PROPERTY ADDRESS: 2012 S 320TH ST, FEDERAL WAY, WA 98003
PROPERTY OWNER: NWCC CENTER PLAZA LLC
LOT SIZE: 260,258 SF
PROJECT BUILDING: III-B CONSTRUCTION, FULL SPRINKLER,
ONE STORY, TOTAL GFA 22,328 SF
OCCUPANCY TYPE: EXISTING: B (ROYALS BARBER SALON)
PROPOSED: B
TENANT SPACE: 1540 SF (LEASING)
SUITE F, 2012 S 320TH ST, FEDERAL WAY, WA 98003
TENANT BUSINESS: EL PAISANO TAMALES KITCHEN
RESTAURANT OWNER: LAURA CAMARENA
206-972-9554
LEGAL DESCRIPTION: PCL B OF FEDERAL WAY LLA# BLA06-1061 11 -SU
REC# 20061229900009 SD LLA BEING LOCATED IN
W 112 OF SE 1/4 OF SW 1/4 OF SEC 9-21-4 - TGW
UND 1/4 INT IN TR X OF KCSP 1077139 REC
#7806301002 LESS POR FOR RD AS PER REC#
20060410002354
PLat Block:
Plat Lot:
PARKING SPACE ANALYSIS:
TENANT SPACE IS ESTABLISHED IN CENTER PLAZA
SHOPPING CENTER, PARKING SPACE IS SHARED USE IN
SHOPPING CENTER PROVIDED PARKING AREA. SINCE
EXISTING TENANT SPACE NOT INCREASE, ADDITIONAL
PARKING SHALL NOT BE REQUIRED.
Q
z
0
N
Q
w
LL-
w
U
Q
z
z
w
w
0
5 3 1 GTH 5T
Q
QPROJECT
m
51TE
>
=
u
Q
LLJ
Z
N
O
w
5 320TH 5T
VICINITY MAP
N (SCALE: N/A )
PROJECT DESCRIPTIONS:
TENANT IMPROVEMENT TO CHANGE USE FROM
EXISTING SALON (ROYALS BARBER SALON) TO
COMMERCIAL KITCHEN WITH NO SEATING (EL PA15ANO
TAMALES KITCHEN) IN 1 540 SF (GFA) TENANT SPACE IN
MIXED USE BUILDING IN CENTER PLAZA.
PROJECT WILL NOT HAVE ANY STRUCTURAL WORK.
EXISTING BUILDING FLOOR AREA NO CHANGE.
EXISTING BUILDING ENVELOP NO CHANGE.
EXISTING CEILING SYSTEM NO CHANGE.
EXISTING HVAC AND DUCTING SYSTEM NO CHANGE
EXISTING RESTROOMS NO CHANGE
DEFERRED SUBMITTAL: PLUMBING, ELECTRICAL,
HOOD SYSTEM, STOREFRONT SIGN, AND FIRE ALARM
SYSTEM MODIFICATION.
CODE COMPLYING:
2016 INTERNATIONAL BUILDING CODE (IBC)
2016 INTERNATIONAL FIRE CODE (IFC)
2016 INTERNATIONAL MECHANICAL CODE (IMC)
2018 INTERNATIONAL FUEL GAS CODE (IFGC)
2018 UNIFORM PLUMBING CODE (UPC)
2018 NATIONAL ELECTRIC CODE (NEC)
2018 WASH I NGTON STATE ENERGY CODE (WSEC)
2009 ICC/ANSI A 1 1 7. 1 ACCESSIBLE AND USABLE
BUILDINGS AND FACILITIES
CITY OF FEDERAL WAY ALL CODE AMENDMENTS
OCCUPANCY LOAD & PLUMBING FIXTURE CALCULATIONS
OCCUPANCY AREA (NET) NET AREA OCCUPANCY LOAD
KITCHEN AND SERVICE AREA 1 063 SF 1 083 / 200 = 5.41
BUSINESS AREA I 29G SF 1 29G / 150 = 1.97 1
KESTROOM * HALLWAY 84 SF 1 84 / 100 = 0.64
TOTAL I 1 4G2 SF I 6.22 9
PLUMBING FIXTURE CALCULATION: (WAC CHAPTER 29, Table 2902. 1 )
MEN: 9 / 2 / 75 = O.OG
LADY: 9 / 2 / 75 = O.OG
REQUIRED: (1) TOILET PER 25 FOR THE FIRST 50, (1) LAVATORY PER 40
FOR THE FIRST 80.
PROVIDE:
(1) TOILET AND (1) LAVATORY, ADA COMPLIANT (FOR EMPLOYEE
USE ONLY)
THIS COMMERCIAL KITCHEN WILL NOT HAVE DINING AREA. THE
COSTUMER AREA LESS THEN 300 SF. NO PUBLIC KESTKOOM PROVIDED
PER IBC 2902.3 EXCEPTION 2.
EXISTING RESTROOM FOR EMPLOYEE USE ONLY
RECEIVED
12/27/21
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
0 o
C") 0
CO
a'
v �I
00
W 0
cfl p co �
r�
V �
N
� q
O �
q
0
0
rn
W Q
U �
H Q
J
W �
w
0
LL
O U)
� o
N
H M
• • Cn
a N
N
V w
LL
W
Cn
O
V4
a
REVISIONS
w
z
a
w aLu
H~
O
cn z
SHEET
Al
DATE: 1 1 /23/202 1