22-104889 (2)�►.a[ILlE- .0 1 RESPONSIBILITY SCHEDULE BUILDING COMPONENT m U) co o _J J z SCHEDULE ABBREVIATIONS GC - GENERAL CONTRACTOR EC - ELECTRICAL CONTRACTOR T - TENANT - TENANT'S VENDOR LL - LANDLORD AE - ARCHITECT REMARKS STOREFRONT STOREFRONT SIGN V V STOREFRONT SIGNS BY TENANT'S SIGN VENDOR ELECTRICAL FOR STOREFRONT SIGN GC GC GC TO PROVIDE POWER IF NONE EXISTS BLADE SIGN N/A EAR PIERCING SIGN CABLE T GC GC/EC TO INSTALL NEW OUTLET FOR PLUG AWNING N/A PAINT GC GC PAINT AS REQUIRED OR PER ELEVATIONS NEUTRAL PIERS GC TO PROTECT AND REPAIR AS NEEDED POWER WASH EXTERIOR GC V GC TO SECURE POWER WASH COMPANY FLOOR FINISHES CONCRETE SLAB N/A PATCH / INFILL MALL FLOORING GC GC GC TO PREPARE ANY FLOOR GETTING NEW FLOORING TILE ADHESIVE (SALES AREA FLOORING) T GC REFER TO FLOORING PLAN REDUCER / TRANSITION STRIPS GC GC REFER TO FLOORING PLAN WOOD BASE I T JGCJ REMOVE EXISTING AND REPLACE WITH NEW WALLS DEMISING PARTITION STUDS N/A DEMISING PARTITION DRYWALL GC GC PATCH AND REPAIR ANY GWB AS REQUIRED FURRING AROUND COLUMNS N/A SALES AREA WALLS GC GC PATCH AND REPAIR ANY GWB AS REQUIRED, PAINT SALES AREA WALL GRAPHICS N/A SALES AREA SHIMMER WALL N/A MID -HEIGHT (8'-0") PARTITION N/A SLATWALL, TRIM, BASE, HARDWARE T GC REFER TO PLANS AND ELEVATIONS ANODIZED ALUMINUM TRIM ON SLATWALL GC GC REFER TO FINISH PLAN, DETAILS AND ELEVATIONS WOOD WALL BASE T GC REFER TO ELEVATIONS CEILINGS GWB CEILINGS AND SOFFITS GC GC PAINT AS REQUIRED SUSPENDED T-BAR CEILING GRID GC GC PAINT AS REQUIRED ACCESS PANELS GC GC SEE REFLECTED CEILING PLAN ACOUSTIC CEILING TILES GC GC SEE REFLECTED CEILING PLAN DOORS STAINLESS SECURITY GRILLE N/A INTERIOR DOORS & FRAMES GC GC REFER TO FLOOR PLAN FOR NEW INTERIOR DOOR HARDWARE GC GC SEE DOOR SCHEDULE STOREFRONT (EXTERIOR) DOORS EXISTING TO REMAIN, SEE DOOR SCHEDULE NOTES FOR HARDWARE STOCKROOM DOOR MIRROR JGCIGCj PROVIDED AND INSTALLED BY GC STOCKROOM BACK DOOR (PEEPHOLE) IGCIGCI PROVIDED AND INSTALLED BY GC FIXTURES & HARDWARE FREESTANDING FLOOR FIXTURES T GC NEW CASHWRAP T GC NEW, INSTALLED BY GC TOWER FIXTURE T GC NEW BOWL FIXTURE T GC NEW, ASSEMBLED BY GC PANEL FIXTURES T GC NEW EARRING TREES T GC NEW EAR PIERCING UNIT AND CHAIR T GC NEW LOOSE HARDWARE & SHELVING T GC NEW LADDER HOOK GC GC GC TO PROVIDE AND INSTALL LADDER HOOK LOCKER T GC SECURED TO WALL BY GC SAFE T GC SECURED TO FLOOR BY GC COAT HOOKS GC GC BOBRICK # B-232 x 24" PROVIDED AND INSTALLED BY GC PHONE BOARD / MEDIA SHELF GC GC SEE DETAIL FOR INSTALL, SEE PLAN FOR LOCATION SIGNAGE EXTERIOR STORE FRONT SIGN V V BY SIGN VENDOR BLADE SIGN N/A VERTICAL EAR PIERCING SIGN V V VENDOR TO INSTALL TENANT -PROVIDED SIGN LED EAR PIERCING SIGN T V/EC VENDOR/ELECTRICAL CONTRACTOR TO INSTALL TENANT -PROVIDED SIGN TRIPTYCH GRAPHIC FRAMES T V VENDOR TO INSTALL TENANT -PROVIDED FRAMES HANGING GOTCHA TRACKS T GC GC TO INSTALL TENANT -PROVIDED TRACKS SHIMMER WALL SIGN N/A MECHANICAL HVAC UNIT(S) GC GC GC TO PERFORM HVAC SURVEY SUPPLY & R/A DUCTWORK EXISTING TO REMAIN DIFFUSERS / GRILLES GC GC EXISTING TO REMAIN, GC TO CLEAN, RELOCATE AS NECESSARY THERMOSTAT GC RELOCATE AS REQUIRED SMOKE EVAC. SYSTEM N/A ELECTRICAL CONDUIT TO SPACE N/A FEEDERS N/A ELECTRICAL PANELS LL LL EXISTING TO REMAIN ELECTRICAL DISTRIBUTION T GC EXISTING TO REMAIN RECEPTACLES GC TERMINATE EXISTING OUTLETS AS REQUIRED LIGHT FIXTURES & LAMPS T GC RE -LAMP EXISTING TO REMAIN PER SCHEDULE / SEE RCP FOR NEW EXIT / EMERGENCY LIGHTS GC GC GC TO INSURE ALL ARE WORKING / SEE RCP FOR NEW TEL. CONDUIT TO SPACE N/A TELEPHONE TERMINAL BOARD GC GC GC TO PROVIDE PLYWOOD/BRACKETS FOR NEW SHELF PHONE, DATA, AUDIO & SECURITY CONDUITS GC GC GC TO PROVIDE CONDUIT PHONE & DATA CABLE N/A PHONE TERMINATIONS N/A SPECIALTIES STOCKROOM DOOR MIRROR GC GC NEW FIRE SPRINKLERS / SYSTEM N/A FIRE ALARM / LIFE SAFETY SYSTEM N/A POS / COMPUTER SYSTEM T COMPUTERS BY TENANT AUDIO SYSTEM T V TENANT'S VENDOR TO INSTALL & CONNECT AUDIO SPEAKERS GC GC TO DETERMINE IF EXISTING SPEAKERS ARE WORKING FIRE EXTINGUISHERS GC GC FIRE MARSHALL TO DETERMINE FINAL LOCATION FIRE RETARDANT MATERIALS GC GC GC TO SPEC. IF APPLICABLE SECURITY CAMERAS T T BY TENANT'S VENDOR, IF REQUIRED SHOPPERTRAK T V TENANT'S VENDOR TO INSTALL AND CONNECT GENERAL REQUIREMENTS PERMITS, FEES, INSURANCE AE AE ARCHITECT TO SUBMIT FOR PERMIT WASTE REMOVAL / DUMPSTER GC GC GC TO PROVIDE DUMPSTER PROFESSIONAL CLEANING GC GC PRIOR TO GC TURNOVER CERTIFICATE OF OCCUPANCY GC GC STOREFRONT BARRICADE GC GC GC TO CONFIRM REQUIREMENTS GRAPHICS FOR STOREFRONT BARRICADE T V TENANT'S VENDOR TO PROVIDE & TO INSTALL IF REQ'D. STORE #6726 - TENANT IMPROVEMENT SEATAC VILLAGE SHOPPING CENTER 1706 S. 320th STREET, SUITE J FEDERAL WAY, WA 98003 CODE REVIEW AUTHORITY: CITY OF FEDERAL WAY CODES: 2018 INTERNATIONAL BUILDING CODE + AMENDMENTS COMMUNITY DEVELOPMENT DEPARTMENT 2018 INTERNATIONAL MECHANICAL CODE + AMENDMENTS BUILDING DIVISION 2018 INTERNATIONAL FIRE CODE + AMENDMENTS S33325 8th AVENUE S. 2018 INTERNATIONAL EXISTING BUILDING CODE FEDERAL WAY, WA 98003 2018 INTERNATIONAL FUEL & GAS CODE PHONE: 253.835.7001 2018 INTERNATIONAL PROPERTY MAINTENANCE CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE + CONSTRUCTION TYPE: II-B (ASSUMED) AMENDMENTS USE GROUP: M-MERCANTILE 2018 WASHING STATE ENERGY CODE 2020 NATIONAL ELECTRICAL CODE + AMENDMENTS FULLY SPRINKLERED: NO 2018 UNIFORM PLUMBING CODE + AMENDMENTS FEDERAL WAY REVISED CODE FIRE ALARM / SMOKE DETECTION SYSTEMS: NO BUILDING HEIGHT: 1 STORY OCCUPANCY CALCULATIONS: TOTAL OCCUPANCY AREA: 1,060 SQUARE FEET SALES AREA: 788 S.F. / 60 S.F. PER PERSON = 13 PEOPLE NON -SALES AREA (EXCLUDES RESTROOM): 272 S.F. / 300 S.F. PER PERSON = 0 PERSON TOTAL OCCUPANT LOAD: 13 PEOPLE NUMBER OF EXITS PROVIDED: 2 MAXIMUM TRAVEL DISTANCE ALLOWED: 200 FEET ACTUAL TRAVEL DISTANCE: 58 FEET GENERAL NOTES PROJECT DIRECTORY TENANT: CLAIRE'S STORES, INC. 2400 W. CENTRAL ROAD HOFFMAN ESTATES, IL 60192 CONTACT: JEFF SCHULTZ, PROJECT MANAGER EMAIL: jeff.schultz@claires.com PH:847.765.2054 CELL:331.422.8024 LANDLORD: CONTACT: LEASING AGENT, MARK PISCITELLI EMAIL: markp@schnitzerproperties.com PH: 503.973.0259 DESIGN WARREN JOHNSON ARCHITECTS ARCHITECT: 19 N. GREELEY STREET PALATINE, IL 60067 PH: 847.359.9616 CONTACT: WARREN JOHNSON EMAIL: wjohnson@wjarch.com ARCHITECT DONNA JEAN BROWN ARCHITECT OF RECORD: PH: 206.547.7860 CONTACT: DONNA JEAN BROWN EMAIL: Donna@DJBArchitect.com FIRE PROTECTION & FIRE ALARM NOTES • THERE IS NO EXISTING AUTOMATIC FIRE SPRINKLER SYSTEM WITHIN THE SPACE. GENERAL CONTRACTOR TO CONTRACT WITH A SPRINKLER SYSTEM CONTRACTOR FOR A COMPLETE SPRINKLER SYSTEM AS NEEDED. • THERE IS NO EXISTING FIRE ALARM NOTIFICATION SYSTEM WITHIN THE SPACE. GENERAL CONTRACTOR TO CONTRACT WITH A FIRE ALARM CONTRACTOR FOR A COMPLETE FIRE ALARM SYSTEM AS NEEDED. SCOPE OF WORK MINOR TENANT IMPROVEMENTS TO EXISTING SUITE J: • NEW WALL FINISHES. • EXISTING SUSPENDED CEILING TO REMAIN. REPLACE TILES AS NEEDED. • NEW FLOOR FINISHES IN SALES AREA AND RESTROOM. • MECHANICAL SCOPE: NO WORK, EXISTING TO REMAIN. • PLUMBING SCOPE: NEW RESTROOM FIXTURES AND WATER HEATER. • ELECTRICAL SCOPE: NEW LIGHTS - ALL AREAS. NEW EMERGENCY LIGHTS / EXIT SIGNS. PROVIDE POWER TO EXTERIOR STOREFRONT SIGN LOCATION. PROVIDE POWER TO NEW CASHWRAP LOCATION. LIST OF DRAWINGS CS-1 COVER SHEET E0.1 ELECTRICAL SPECS. ASP-1 ARCHITECTURAL SPECS. E1.0 LIGHTING PLAN D-1 DEMO PLANS E2.0 POWER PLAN A-1 FLOOR PLAN E3.0 PANELS & RISER DIAGRAM A-1.1 DETAILS M1.0 MECHANICAL PLAN A-2 REFLECTED CEILING PLAN M1.1 MECHANICAL SCHEDULES A-3 FIXTURE PLAN P1.0 PLUMBING DWV PLAN A-4 POWER AND SIGNAL PLAN A-5 ELEVATIONS A-5.1 ELEVATIONS SYMBOL LEGEND 100 ROOM NUMBER 3 PT 1 INTERIOR FINISH SALES AREA --ROOM NAME a -�\ NUMBER 1 SECTION DETAIL ��_.' WALL TYPE TAG n5 REFERENCE REFERENCE ODOOR NUMBER TAG ELEVATION HEIGHT a 5 REFERENCE ELEVATION-- COLUMN LINE TAG CONTRACTOR GENERAL NOTES • EXISTING STOREFRONT DOORS SHALL BE SUPPLIED WITH HARDWARE THAT CONFORMS TO CURRENT ADOPTED CODES AND STANDARDS. • THIS REVIEW DOES NOT DISSOLVE THE REQUIREMENTS TO MEET ALL CURRENT ADOPTED CITY CODES AND REGULATIONS. ANY IDENTIFIED ITEMS THROUGHOUT THE PROJECT NOT MEETING THE CODE WILL NEED TO BE CORRECTED TO MEET THE INTENT OF THE CODE PRIOR TO GETTING A CERTIFICATE OF OCCUPANCY. • MAINTAIN CLEARANCE IN FRONT OF ALL ELECTRICAL EQUIPMENT. THE FLOOR SHALL BE MARKED IN FRONT OF EQUIPMENT TO SHOW WHERE NO STORAGE IS ALLOWED. 1. ALL WORK TO COMPLY WITH THE CURRENT FEDERAL ADA STANDARD. 2. ALL CONTRACTORS AND SUBCONTRACTORS WILL THOROUGHLY FAMILIARIZE THEMSELVES WITH THESE CONSTRUCTION DOCUMENTS. ALL SUBCONTRACTORS WILL PROVIDE ALL LABOR, SUPERVISION, AND MATERIALS AND EVERYTHING OF EVERY SORT WHICH MAY BE NECESSARY FOR A SUCCESSFUL COMPLETION OF THIS PROJECT TO OBTAIN A FINAL OCCUPANCY PERMIT. ALL WORK TO BE PERFORMED IN A GOOD AND WORKMANLIKE MANNER AS DESCRIBED HEREIN BY THESE CONSTRUCTION DOCUMENTS ACCORDING TO THE TRUE INTENT AND MEANING OF THE DRAWINGS AND SPECIFICATIONS. WHETHER THE SAME MAY OR MAY NOT BE PARTICULARLY INFERRED THEREFROM ALL WORK INDICATED OR DESCRIBED IN THE DRAWINGS OR SPECIFICATIONS WILL BE CONFERRED BY THE CONTRACT TO THE EXTENT AS IF DESCRIBED IN BOTH. 3. SUBCONTRACTORS, BEFORE STARTING THEIR WORK, WILL CHECK AND VERIFY THEIR PARTICULAR CODE RELATED REQUIREMENTS FOR COMPLIANCE ALONG WITH MEASUREMENTS, SURFACE LEVELS, SURFACE CONDITIONS AND RELATED PRODUCT, INSTALLATIONS NEAR AND ABOUT THEIR WORK. EACH TRADE WILL VERIFY IF CONTRACT CONDITIONS WITH THE OWNER OR THE ON -SITE CONSTRUCTION MANAGER AS TO IF THEY ARE OR NOT OF THE SAME, AS PER THESE CONSTRUCTION DOCUMENTS. 4. THIS ARCHITECT AND HIS PROFESSIONAL CONSULTANTS WILL NOT HAVE CONTROL OR CHANGE OF AND WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK ON THIS PROJECT OR FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK ON THIS SITE, NOR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE INTENT OF THE CONTRACT AND OR CONSTRUCTION DOCUMENTS. 5. ALL WORK WILL BE COORDINATED WITH OTHER TRADES IN ORDER TO AVOID INTERFERENCE AND PRESERVE MAXIMUM HEADROOM AND AVOID OMISSIONS. EACH CONTRACTOR WILL INCLUDE ALL MISCELLANEOUS ITEMS REQUIRED BY CODE AND NEEDED TO COMPLETE THE WORK INCLUDING MOVING AND RIGGING OF MATERIALS AND EQUIPMENT, ALL THE HANGERS, SUPPORTS, ANCHORS, SUSPENSION MEANS, CONDUIT, WIRE, FITTINGS, SLEEVES, ETC. 6. ALL MATERIALS USED WILL BE NEW AND BEAR U.L. LABELS WHERE REQUIRED AND MEET APPROPRIATE N.E.M.A. STANDARDS. 7. LAYOUT ALL PARTITIONS BEFORE BEGINNING CONSTRUCTION TO PREVENT ERRORS BY DISCREPANCY. ALL DRYWALL PARTITIONS WILL BE INSTALLED AS NOTED ON THE DRAWINGS. 8. ALL CONTRACTORS WILL GUARANTEE ALL LABOR AND MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF ISSUE OF FINAL OCCUPANCY PERMIT AND/OR AT THE FINAL PAYOUT FROM OWNER. 9. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING, CUTTING AND/OR INSTALLING MATERIAL, PRODUCT OR EQUIPMENT. IN THE EVENT OF ANY DISCREPANCIES, CONTACT THE ARCHITECT BEFORE PROCEEDING WITH THAT WORK. 10. GENERAL SHEET NOTES ARE APPLICABLE ONLY WHEN STATED CONDITIONS ARE WITHIN THE SCOPE OF WORK. 11. ALL COMMUNICATIONS WITH CLAIRE'S ARCHITECT OR ENGINEER MUST REFERENCE THE PROJECT STORE NUMBER LOCATED ON EACH SHEET. 12. NO SUBSTITUTIONS OF ANY KIND FOR MATERIALS SPECIFIED ON THESE CONSTRUCTION DOCUMENTS IS ALLOWED. NO "EQUIVALENT" SUBSTITUTIONS WILL BE MADE, UNLESS APPROVED IN WRITING BY THE ARCHITECT AND APPROVED BY THE OWNER, DUE TO THE LACK OF AVAILABILITY OF ORIGINAL. 13. RESPONSIBILITY OF CONTRACTOR: EACH CONTRACTOR IS RESPONSIBLE FOR AND MUST GUARANTEE IN WRITING FIRST CLASS WORKMANSHIP AND MATERIALS. EACH CONTRACTOR WILL ASSUME ALL RESPONSIBILITY FOR THE CARE AND PROTECTION OF HIS OWN WORK AND MATERIALS FROM DAMAGE AND WILL PROTECT THIS SAME PROPERTY. HE WILL MAKE GOOD ANY DAMAGE TO HIS OWN OR OTHER WORK CAUSED BY HIMSELF OR WORKMEN EMPLOYED BY HIM. 14. SITE SAFETY: EACH CONTRACTOR WILL ABIDE BY LOCAL AREA STANDARDS AND RELATED OSHA STANDARDS FOR THE PROTECTION AND SAFETY FOR THEIR EMPLOYEES ON SITE. THIS ARCHITECT AND HIS PROFESSIONAL CONSULTANTS WILL BE HELD HARMLESS BY THE OWNER, GENERAL CONTRACTOR AND RELATED AWARDED TRADES, ON THIS PROJECT FOR ACCIDENTS OR INJURIES CAUSED OR ACCRUED ON THIS PROPERTY DURING THE PRE/ACTUAL/POST CONSTRUCTION PHASES OF THIS PROJECT. 15. GENERAL CONTRACTOR TO PAY FOR ALL SCAVENGER SERVICES, AND WILL BE RESPONSIBLE FOR REMOVAL OF DEBRIS ACCUMULATED BY EACH TRADE. HOWEVER, EACH TRADE WILL KEEP THE JOB SITE CLEAN AND SAFE AT ALL TIMES, ALONG WITH A BROOM FINISH AT THE END OF EACH WORKING DAY. 16. IF CHANGES ARE MADE IN THE FIELD ON THIS PROJECT VIA DIMENSIONS, MATERIALS, INSTALLATION DIFFERENT THAN INDUSTRY TECHNIQUES AND STANDARDS, ETC., "CONSTRUCTION MANAGER" IS TO BE NOTIFIED 48 HOURS IN ADVANCE TO THESE CHANGES TO BE MADE BY SAID TRADE. IF NOTICE IS NOT GIVEN TO THE C.M., THEN THAT SUBCONTRACTOR IS TOTALLY RESPONSIBLE FOR THE CONSEQUENCES AND EFFECTS EVOLVED FROM THESE CHANGES. 17. CONSTRUCTION CLEAN-UP: AFTER ALL OTHER WORK IS COMPLETED AND JUST PRIOR TO TURNING THE SPACE OVER TO THE OWNER, THE CONSTRUCTION MANAGER WILL EMPLOY THE SERVICES OF A PROFESSIONAL CLEANING SERVICES TO CLEAN AND WASH DOWN ALL INSTALLED EQUIPMENT, SERVICE AREAS, ALONG WITH THE CLEANING OF ALL GLASS WINDOW/DOOR SURFACES PRIOR TO OCCUPANCY. ALL WORK SHALL CONFORM TO THE APPLICABLE CODES FOR THIS MUNICIPALITY. SEE 'CODE REVIEW' ON THIS SHEET. 18. DO NOT SCALE DRAWINGS. 19. CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK AT ANY TIME WITHOUT APPROVED CONTRACT DOCUMENTS. 20. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL ARCHITECTURAL, MECHANICAL, TELEPHONE, ELECTRICAL (INCLUDING LIGHTING), AND PLUMBING SO TO ENSURE THAT REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ALL EQUIPMENT ARE PROVIDED. 21. DIMENSIONS SHALL NOT BE CHANGED WITHOUT THE ARCHITECTS WRITTEN APPROVAL. 22. CONTRACTOR TO PROTECT EXISTING CONSTRUCTION AND RESTORE ALL FINISH SURFACES TO THEIR ORIGINAL CONDITION WHERE DAMAGED. PROJECT LOCATION NO SCALE ,jasmine rnangonan urui T St 531fith S3t51hSt Nara Villag-e i LansC rsf=�rs To wn gtrare Park 83161hPI KamKdrlg S3q} Lre II BBQ Grill Buffet : ru N Trader Joe's 19 q0 I i Batteries Plus Bulbs ,Mexican Grill I BstlErrstole Harbor Freigill Tp.6Is19 I SJ f 5 3"th St I Chick-fil-A9 SEATAC VILLAGE SHOPPING CENTER FEDERAL WAY, WA 98003 IPT.J Maxx S 31 S[h P! SeaTac Village Shopping Center cw Beauty Red Lobster 19 C'�9m _litj s7UK 9 Center Plaza S32uzh St S 32M St KEY PLAN NO SCALE 1706 S. 320th STREET SUITE J rader HatneGood o Dsw T.J. MB!lSiL BIG ❑ S 324TH ST 1;xr A RECEIVED Nov 15 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 4_0 U 00 U or) i Q Q � dj E: O M� W a U U Z > � cfl ti _ m 0 O C) L0 ti � O "! 2i CV O _ CO) M O MO W M Q LLJ Z LU J �Un Q/ V 0!. c0 z w CV � C) COLLJ LL. lk O 1 W W w LU Q ::D^^ � v J U J -- U w W LLJ _4­0 W O CV M V J (-0 O ti IV - PROJECT NUMBER: WJA-22077 PERMIT REVIEW 10-18-2022 I REVISIONS L I COVER SHEET CS-1 SHEET 1 OF 10 ,► CITY" PERMIT APPLICATION � PER Federal Way MIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003 6325 253-835-2607 + FAX 253-835-2609 + permiteenterCcltyoffederalway com PERMIT NUMBER _ - � TARGET DATE SITE ADDRESS 1 1�7 a& u40(-% 6.5""T'C' SUITE/UNIT PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL I $ (V1000. 00 G G _o _!i- a,_L TYPE OF PERMIT P1 BUILDING ® PLUMBING JO MECHANICAL 0 DEMOLITION 11 ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT Cl a-t r -r- IS T + P.YIty PROJECT DESCRIPTION Detailed description of work to i new `i .• I be included on this permit only LJ NAME 60._r 1 1 Ci PRIMARY PHONE PROPERTY OWNER MAILING ADDRESS E-MAIL CITY w w� ZIP g8005 NAME PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE EXPIRATION DATE UBI NAME , rl W 1 - 1Ntt�rrcvl 0hr+ h cki PRIMARY PHONE T- 59 - 9 Gi MAILING ADDRESS rsQl 5-rr E-MAIL lal1k� ox-c6 • f'c IV APPLICANT � L (' h /A. _ . tV / VNMre 5 CITY STATE alR.�ine. TL_ ZIP 0041 FAX $459-9441 PROJECT CONTACT NAME Karr1 O'k - YU6YCtA 506nsW% Acrt 1 MARY PHONE -7 - 3-rq _ 11el � MAILING ADD _ _ I 1 « 57'r eA+ (The individual to receive and respond to all correspondence r CITY STATE al'Jrut, z>r ZIP !s o 0 uI FAX Ml- 351- 4 441 concerning this application) PROJECT FINANCING NAME L • �� S S' OWNER -FINANCED When value is $5,000 or more IRCW 19.27 0951 MAILING ADDRESS, CITY, STATE, ZIP 1,40 a W • C"+V mil s PHONE e Orr - 7(,s - 7-D54 I certify under penalty of perjury that I am the property owner or authorised agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit. I understand that the Issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental taws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and flied against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the h1formation supplied to the city as apart of t1h`istappQliccation� SIGNATURE: ' DATE PRINT NAME: 1 •► L=&M�i S Bulletin #100 February 19, 2020 Page 1 of k:'.Ilandouts%Permlt Application 12 VALUE OF MECHANICAL WORK MECHANICAL PERMIT $ 00o.00 Indicate holy many o each type o ucture to be installed or relocated as part of this project, Do not include exisang inures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER IDweribe) AIR CONDITIONER FIREPLACE INSERTS HOODS Ico,m. -w) BOILERS FURNACES HOT WATER TANKS Ica., COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT 1$2-000-bo Indicate how many of each Igoe offixture to be installed or relocated as Cart of this project. Do not include existing fixtures to remain. BATHTUBS LAVS jif—dSmkej TOILETS �_ WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS IKAcn,,,:-,-,1,1yl —I—, WATER HEATERS HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURE$ GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEVER PURVEYOR VALUE OF EXISTING IMPROVEMENTS $ wwk,+tiewn EXISTI((N��G/PREVIOUS USE LOT SIZE IlnSquere Feetl EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? y1% 1,yk455 (40 +11; ` Yes X No ; , Yes X No RESIDENTIAL -NEW OR ADDITION AREA DESCRIPTION (in square feetl EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMENT FIRST FLOOR (or Mobile Home) SECOND FLOOR COVERED ENTRY DECK GARAGE 0 CARPORT L] OTHER (describe) Area Totals E1dSTWO PROPOSED 'TOTAL "NEWHOMM ORLY"e ESTIMATED SELLING PRICE $ 1 # OF BEDROOMS COMMERCIAL - NEWADDITION AREA DESCRIPTION Area in S are Feet Occupancy Grouplsl Construction # of Stories Additional Information NBW BumviN(o ADDITION COMMERCIAL - REMODEUTENANT IMPROVEMENTS AREA DESCRIPTION Area in Square FeetType Occupancy Group(s) Construction 0 of Stories Additional Information TOTAL BUILIDEla � S�' #Vk-x4Af/ &S TENANT AREA ONLY I /�, ^�� M •w C&1„r4y' 1,& 1 PRO.fEC1 AREA ONLY 22 ( � - 1 Bulletin 000 February 19, 2020 Page 2 of 2 k: Handouts Permit Applic mon