RESPONSIBILITY SCHEDULE
BUILDING COMPONENT
m
U)
co
o
_J
J
z
SCHEDULE ABBREVIATIONS
GC - GENERAL CONTRACTOR
EC - ELECTRICAL CONTRACTOR
T - TENANT
- TENANT'S VENDOR
LL - LANDLORD
AE - ARCHITECT
REMARKS
STOREFRONT
STOREFRONT SIGN
V
V
STOREFRONT SIGNS BY TENANT'S SIGN VENDOR
ELECTRICAL FOR STOREFRONT SIGN
GC
GC
GC TO PROVIDE POWER IF NONE EXISTS
BLADE SIGN
N/A
EAR PIERCING SIGN CABLE
T
GC
GC/EC TO INSTALL NEW OUTLET FOR PLUG
AWNING
N/A
PAINT
GC
GC
PAINT AS REQUIRED OR PER ELEVATIONS
NEUTRAL PIERS
GC TO PROTECT AND REPAIR AS NEEDED
POWER WASH EXTERIOR
GC
V
GC TO SECURE POWER WASH COMPANY
FLOOR FINISHES
CONCRETE SLAB
N/A
PATCH / INFILL MALL FLOORING
GC
GC
GC TO PREPARE ANY FLOOR GETTING NEW FLOORING
TILE ADHESIVE (SALES AREA FLOORING)
T
GC
REFER TO FLOORING PLAN
REDUCER / TRANSITION STRIPS
GC
GC
REFER TO FLOORING PLAN
WOOD BASE
I T
JGCJ
REMOVE EXISTING AND REPLACE WITH NEW
WALLS
DEMISING PARTITION STUDS
N/A
DEMISING PARTITION DRYWALL
GC
GC
PATCH AND REPAIR ANY GWB AS REQUIRED
FURRING AROUND COLUMNS
N/A
SALES AREA WALLS
GC
GC
PATCH AND REPAIR ANY GWB AS REQUIRED, PAINT
SALES AREA WALL GRAPHICS
N/A
SALES AREA SHIMMER WALL
N/A
MID -HEIGHT (8'-0") PARTITION
N/A
SLATWALL, TRIM, BASE, HARDWARE
T
GC
REFER TO PLANS AND ELEVATIONS
ANODIZED ALUMINUM TRIM ON SLATWALL
GC
GC
REFER TO FINISH PLAN, DETAILS AND ELEVATIONS
WOOD WALL BASE
T
GC
REFER TO ELEVATIONS
CEILINGS
GWB CEILINGS AND SOFFITS
GC
GC
PAINT AS REQUIRED
SUSPENDED T-BAR CEILING GRID
GC
GC
PAINT AS REQUIRED
ACCESS PANELS
GC
GC
SEE REFLECTED CEILING PLAN
ACOUSTIC CEILING TILES
GC
GC
SEE REFLECTED CEILING PLAN
DOORS
STAINLESS SECURITY GRILLE
N/A
INTERIOR DOORS & FRAMES
GC
GC
REFER TO FLOOR PLAN FOR NEW
INTERIOR DOOR HARDWARE
GC
GC
SEE DOOR SCHEDULE
STOREFRONT (EXTERIOR) DOORS
EXISTING TO REMAIN, SEE DOOR SCHEDULE NOTES FOR HARDWARE
STOCKROOM DOOR MIRROR
JGCIGCj
PROVIDED AND INSTALLED BY GC
STOCKROOM BACK DOOR (PEEPHOLE)
IGCIGCI
PROVIDED AND INSTALLED BY GC
FIXTURES & HARDWARE
FREESTANDING FLOOR FIXTURES
T
GC
NEW
CASHWRAP
T
GC
NEW, INSTALLED BY GC
TOWER FIXTURE
T
GC
NEW
BOWL FIXTURE
T
GC
NEW, ASSEMBLED BY GC
PANEL FIXTURES
T
GC
NEW
EARRING TREES
T
GC
NEW
EAR PIERCING UNIT AND CHAIR
T
GC
NEW
LOOSE HARDWARE & SHELVING
T
GC
NEW
LADDER HOOK
GC
GC
GC TO PROVIDE AND INSTALL LADDER HOOK
LOCKER
T
GC
SECURED TO WALL BY GC
SAFE
T
GC
SECURED TO FLOOR BY GC
COAT HOOKS
GC
GC
BOBRICK # B-232 x 24" PROVIDED AND INSTALLED BY GC
PHONE BOARD / MEDIA SHELF
GC
GC
SEE DETAIL FOR INSTALL, SEE PLAN FOR LOCATION
SIGNAGE
EXTERIOR STORE FRONT SIGN
V
V
BY SIGN VENDOR
BLADE SIGN
N/A
VERTICAL EAR PIERCING SIGN
V
V
VENDOR TO INSTALL TENANT -PROVIDED SIGN
LED EAR PIERCING SIGN
T
V/EC
VENDOR/ELECTRICAL CONTRACTOR TO INSTALL TENANT -PROVIDED SIGN
TRIPTYCH GRAPHIC FRAMES
T
V
VENDOR TO INSTALL TENANT -PROVIDED FRAMES
HANGING GOTCHA TRACKS
T
GC
GC TO INSTALL TENANT -PROVIDED TRACKS
SHIMMER WALL SIGN
N/A
MECHANICAL
HVAC UNIT(S)
GC
GC
GC TO PERFORM HVAC SURVEY
SUPPLY & R/A DUCTWORK
EXISTING TO REMAIN
DIFFUSERS / GRILLES
GC
GC
EXISTING TO REMAIN, GC TO CLEAN, RELOCATE AS NECESSARY
THERMOSTAT
GC
RELOCATE AS REQUIRED
SMOKE EVAC. SYSTEM
N/A
ELECTRICAL
CONDUIT TO SPACE
N/A
FEEDERS
N/A
ELECTRICAL PANELS
LL
LL
EXISTING TO REMAIN
ELECTRICAL DISTRIBUTION
T
GC
EXISTING TO REMAIN
RECEPTACLES
GC
TERMINATE EXISTING OUTLETS AS REQUIRED
LIGHT FIXTURES & LAMPS
T
GC
RE -LAMP EXISTING TO REMAIN PER SCHEDULE / SEE RCP FOR NEW
EXIT / EMERGENCY LIGHTS
GC
GC
GC TO INSURE ALL ARE WORKING / SEE RCP FOR NEW
TEL. CONDUIT TO SPACE
N/A
TELEPHONE TERMINAL BOARD
GC
GC
GC TO PROVIDE PLYWOOD/BRACKETS FOR NEW SHELF
PHONE, DATA, AUDIO & SECURITY CONDUITS
GC
GC
GC TO PROVIDE CONDUIT
PHONE & DATA CABLE
N/A
PHONE TERMINATIONS
N/A
SPECIALTIES
STOCKROOM DOOR MIRROR
GC
GC
NEW
FIRE SPRINKLERS / SYSTEM
N/A
FIRE ALARM / LIFE SAFETY SYSTEM
N/A
POS / COMPUTER SYSTEM
T
COMPUTERS BY TENANT
AUDIO SYSTEM
T
V
TENANT'S VENDOR TO INSTALL & CONNECT
AUDIO SPEAKERS
GC
GC TO DETERMINE IF EXISTING SPEAKERS ARE WORKING
FIRE EXTINGUISHERS
GC
GC
FIRE MARSHALL TO DETERMINE FINAL LOCATION
FIRE RETARDANT MATERIALS
GC
GC
GC TO SPEC. IF APPLICABLE
SECURITY CAMERAS
T
T
BY TENANT'S VENDOR, IF REQUIRED
SHOPPERTRAK
T
V
TENANT'S VENDOR TO INSTALL AND CONNECT
GENERAL REQUIREMENTS
PERMITS, FEES, INSURANCE
AE
AE
ARCHITECT TO SUBMIT FOR PERMIT
WASTE REMOVAL / DUMPSTER
GC
GC
GC TO PROVIDE DUMPSTER
PROFESSIONAL CLEANING
GC
GC
PRIOR TO GC TURNOVER
CERTIFICATE OF OCCUPANCY
GC
GC
STOREFRONT BARRICADE
GC
GC
GC TO CONFIRM REQUIREMENTS
GRAPHICS FOR STOREFRONT BARRICADE
T
V
TENANT'S VENDOR TO PROVIDE & TO INSTALL IF REQ'D.
STORE #6726 - TENANT IMPROVEMENT
SEATAC VILLAGE SHOPPING CENTER
1706 S. 320th STREET, SUITE J
FEDERAL WAY, WA 98003
CODE REVIEW
AUTHORITY: CITY OF FEDERAL WAY
CODES:
2018 INTERNATIONAL BUILDING CODE + AMENDMENTS
COMMUNITY DEVELOPMENT DEPARTMENT
2018 INTERNATIONAL MECHANICAL CODE + AMENDMENTS
BUILDING DIVISION
2018 INTERNATIONAL FIRE CODE + AMENDMENTS
S33325 8th AVENUE S.
2018 INTERNATIONAL EXISTING BUILDING CODE
FEDERAL WAY, WA 98003
2018 INTERNATIONAL FUEL & GAS CODE
PHONE: 253.835.7001
2018 INTERNATIONAL PROPERTY MAINTENANCE CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE +
CONSTRUCTION TYPE:
II-B (ASSUMED)
AMENDMENTS
USE GROUP:
M-MERCANTILE
2018 WASHING STATE ENERGY CODE
2020 NATIONAL ELECTRICAL CODE + AMENDMENTS
FULLY SPRINKLERED:
NO
2018 UNIFORM PLUMBING CODE + AMENDMENTS
FEDERAL WAY REVISED CODE
FIRE ALARM / SMOKE DETECTION SYSTEMS:
NO
BUILDING HEIGHT:
1 STORY
OCCUPANCY CALCULATIONS:
TOTAL OCCUPANCY AREA:
1,060 SQUARE FEET
SALES AREA:
788 S.F. / 60 S.F. PER PERSON = 13 PEOPLE
NON -SALES AREA (EXCLUDES RESTROOM):
272 S.F. / 300 S.F. PER PERSON = 0 PERSON
TOTAL OCCUPANT LOAD:
13 PEOPLE
NUMBER OF EXITS PROVIDED: 2
MAXIMUM TRAVEL DISTANCE ALLOWED: 200 FEET
ACTUAL TRAVEL DISTANCE: 58 FEET
GENERAL NOTES
PROJECT DIRECTORY
TENANT: CLAIRE'S STORES, INC.
2400 W. CENTRAL ROAD
HOFFMAN ESTATES, IL 60192
CONTACT: JEFF SCHULTZ, PROJECT MANAGER
EMAIL: jeff.schultz@claires.com
PH:847.765.2054 CELL:331.422.8024
LANDLORD: CONTACT: LEASING AGENT, MARK PISCITELLI
EMAIL: markp@schnitzerproperties.com
PH: 503.973.0259
DESIGN
WARREN JOHNSON ARCHITECTS
ARCHITECT:
19 N. GREELEY STREET
PALATINE, IL 60067
PH: 847.359.9616
CONTACT: WARREN JOHNSON
EMAIL: wjohnson@wjarch.com
ARCHITECT
DONNA JEAN BROWN ARCHITECT
OF RECORD:
PH: 206.547.7860
CONTACT: DONNA JEAN BROWN
EMAIL: Donna@DJBArchitect.com
FIRE PROTECTION
& FIRE ALARM NOTES
• THERE IS NO EXISTING AUTOMATIC FIRE SPRINKLER SYSTEM WITHIN THE SPACE.
GENERAL CONTRACTOR TO CONTRACT WITH A SPRINKLER SYSTEM CONTRACTOR
FOR A COMPLETE SPRINKLER SYSTEM AS NEEDED.
• THERE IS NO EXISTING FIRE ALARM NOTIFICATION SYSTEM WITHIN THE SPACE.
GENERAL CONTRACTOR TO CONTRACT WITH A FIRE ALARM CONTRACTOR FOR A
COMPLETE FIRE ALARM SYSTEM AS NEEDED.
SCOPE OF WORK
MINOR TENANT IMPROVEMENTS TO EXISTING SUITE J:
• NEW WALL FINISHES.
• EXISTING SUSPENDED CEILING TO REMAIN. REPLACE TILES AS NEEDED.
• NEW FLOOR FINISHES IN SALES AREA AND RESTROOM.
• MECHANICAL SCOPE: NO WORK, EXISTING TO REMAIN.
• PLUMBING SCOPE: NEW RESTROOM FIXTURES AND WATER HEATER.
• ELECTRICAL SCOPE: NEW LIGHTS - ALL AREAS. NEW EMERGENCY LIGHTS /
EXIT SIGNS. PROVIDE POWER TO EXTERIOR STOREFRONT SIGN LOCATION.
PROVIDE POWER TO NEW CASHWRAP LOCATION.
LIST OF
DRAWINGS
CS-1
COVER SHEET
E0.1
ELECTRICAL SPECS.
ASP-1
ARCHITECTURAL SPECS.
E1.0
LIGHTING PLAN
D-1
DEMO PLANS
E2.0
POWER PLAN
A-1
FLOOR PLAN
E3.0
PANELS & RISER DIAGRAM
A-1.1
DETAILS
M1.0
MECHANICAL PLAN
A-2
REFLECTED CEILING PLAN
M1.1
MECHANICAL SCHEDULES
A-3
FIXTURE PLAN
P1.0
PLUMBING DWV PLAN
A-4
POWER AND SIGNAL PLAN
A-5
ELEVATIONS
A-5.1
ELEVATIONS
SYMBOL LEGEND
100 ROOM NUMBER 3 PT 1 INTERIOR FINISH
SALES AREA --ROOM NAME a -�\ NUMBER
1 SECTION DETAIL ��_.' WALL TYPE TAG
n5 REFERENCE REFERENCE
ODOOR NUMBER TAG
ELEVATION HEIGHT
a 5 REFERENCE ELEVATION-- COLUMN LINE TAG
CONTRACTOR GENERAL NOTES
• EXISTING STOREFRONT DOORS SHALL BE SUPPLIED WITH HARDWARE THAT CONFORMS TO
CURRENT ADOPTED CODES AND STANDARDS.
• THIS REVIEW DOES NOT DISSOLVE THE REQUIREMENTS TO MEET ALL CURRENT ADOPTED
CITY CODES AND REGULATIONS. ANY IDENTIFIED ITEMS THROUGHOUT THE PROJECT NOT
MEETING THE CODE WILL NEED TO BE CORRECTED TO MEET THE INTENT OF THE CODE
PRIOR TO GETTING A CERTIFICATE OF OCCUPANCY.
• MAINTAIN CLEARANCE IN FRONT OF ALL ELECTRICAL EQUIPMENT. THE FLOOR SHALL BE
MARKED IN FRONT OF EQUIPMENT TO SHOW WHERE NO STORAGE IS ALLOWED.
1. ALL WORK TO COMPLY WITH THE CURRENT FEDERAL ADA STANDARD.
2. ALL CONTRACTORS AND SUBCONTRACTORS WILL THOROUGHLY FAMILIARIZE THEMSELVES WITH THESE CONSTRUCTION DOCUMENTS. ALL SUBCONTRACTORS WILL PROVIDE ALL LABOR, SUPERVISION, AND MATERIALS AND EVERYTHING OF EVERY SORT WHICH
MAY BE NECESSARY FOR A SUCCESSFUL COMPLETION OF THIS PROJECT TO OBTAIN A FINAL OCCUPANCY PERMIT. ALL WORK TO BE PERFORMED IN A GOOD AND WORKMANLIKE MANNER AS DESCRIBED HEREIN BY THESE CONSTRUCTION DOCUMENTS
ACCORDING TO THE TRUE INTENT AND MEANING OF THE DRAWINGS AND SPECIFICATIONS. WHETHER THE SAME MAY OR MAY NOT BE PARTICULARLY INFERRED THEREFROM ALL WORK INDICATED OR DESCRIBED IN THE DRAWINGS OR SPECIFICATIONS WILL BE
CONFERRED BY THE CONTRACT TO THE EXTENT AS IF DESCRIBED IN BOTH.
3. SUBCONTRACTORS, BEFORE STARTING THEIR WORK, WILL CHECK AND VERIFY THEIR PARTICULAR CODE RELATED REQUIREMENTS FOR COMPLIANCE ALONG WITH MEASUREMENTS, SURFACE LEVELS, SURFACE CONDITIONS AND RELATED PRODUCT,
INSTALLATIONS NEAR AND ABOUT THEIR WORK. EACH TRADE WILL VERIFY IF CONTRACT CONDITIONS WITH THE OWNER OR THE ON -SITE CONSTRUCTION MANAGER AS TO IF THEY ARE OR NOT OF THE SAME, AS PER THESE CONSTRUCTION DOCUMENTS.
4. THIS ARCHITECT AND HIS PROFESSIONAL CONSULTANTS WILL NOT HAVE CONTROL OR CHANGE OF AND WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND
PROGRAMS IN CONNECTION WITH THE WORK ON THIS PROJECT OR FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK ON THIS SITE, NOR FOR THE FAILURE OF ANY OF THEM TO
CARRY OUT THE WORK IN ACCORDANCE WITH THE INTENT OF THE CONTRACT AND OR CONSTRUCTION DOCUMENTS.
5. ALL WORK WILL BE COORDINATED WITH OTHER TRADES IN ORDER TO AVOID INTERFERENCE AND PRESERVE MAXIMUM HEADROOM AND AVOID OMISSIONS. EACH CONTRACTOR WILL INCLUDE ALL MISCELLANEOUS ITEMS REQUIRED BY CODE AND NEEDED TO
COMPLETE THE WORK INCLUDING MOVING AND RIGGING OF MATERIALS AND EQUIPMENT, ALL THE HANGERS, SUPPORTS, ANCHORS, SUSPENSION MEANS, CONDUIT, WIRE, FITTINGS, SLEEVES, ETC.
6. ALL MATERIALS USED WILL BE NEW AND BEAR U.L. LABELS WHERE REQUIRED AND MEET APPROPRIATE N.E.M.A. STANDARDS.
7. LAYOUT ALL PARTITIONS BEFORE BEGINNING CONSTRUCTION TO PREVENT ERRORS BY DISCREPANCY. ALL DRYWALL PARTITIONS WILL BE INSTALLED AS NOTED ON THE DRAWINGS.
8. ALL CONTRACTORS WILL GUARANTEE ALL LABOR AND MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF ISSUE OF FINAL OCCUPANCY PERMIT AND/OR AT THE FINAL PAYOUT FROM OWNER.
9. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO ORDERING, CUTTING AND/OR INSTALLING MATERIAL, PRODUCT OR EQUIPMENT. IN THE EVENT OF ANY DISCREPANCIES, CONTACT THE ARCHITECT BEFORE PROCEEDING WITH THAT WORK.
10. GENERAL SHEET NOTES ARE APPLICABLE ONLY WHEN STATED CONDITIONS ARE WITHIN THE SCOPE OF WORK.
11. ALL COMMUNICATIONS WITH CLAIRE'S ARCHITECT OR ENGINEER MUST REFERENCE THE PROJECT STORE NUMBER LOCATED ON EACH SHEET.
12. NO SUBSTITUTIONS OF ANY KIND FOR MATERIALS SPECIFIED ON THESE CONSTRUCTION DOCUMENTS IS ALLOWED. NO "EQUIVALENT" SUBSTITUTIONS WILL BE MADE, UNLESS APPROVED IN WRITING BY THE ARCHITECT AND APPROVED BY THE OWNER,
DUE TO THE LACK OF AVAILABILITY OF ORIGINAL.
13. RESPONSIBILITY OF CONTRACTOR: EACH CONTRACTOR IS RESPONSIBLE FOR AND MUST GUARANTEE IN WRITING FIRST CLASS WORKMANSHIP AND MATERIALS. EACH CONTRACTOR WILL ASSUME ALL RESPONSIBILITY FOR THE CARE AND PROTECTION OF HIS
OWN WORK AND MATERIALS FROM DAMAGE AND WILL PROTECT THIS SAME PROPERTY. HE WILL MAKE GOOD ANY DAMAGE TO HIS OWN OR OTHER WORK CAUSED BY HIMSELF OR WORKMEN EMPLOYED BY HIM.
14. SITE SAFETY: EACH CONTRACTOR WILL ABIDE BY LOCAL AREA STANDARDS AND RELATED OSHA STANDARDS FOR THE PROTECTION AND SAFETY FOR THEIR EMPLOYEES ON SITE. THIS ARCHITECT AND HIS PROFESSIONAL CONSULTANTS WILL BE HELD
HARMLESS BY THE OWNER, GENERAL CONTRACTOR AND RELATED AWARDED TRADES, ON THIS PROJECT FOR ACCIDENTS OR INJURIES CAUSED OR ACCRUED ON THIS PROPERTY DURING THE PRE/ACTUAL/POST CONSTRUCTION PHASES OF THIS PROJECT.
15. GENERAL CONTRACTOR TO PAY FOR ALL SCAVENGER SERVICES, AND WILL BE RESPONSIBLE FOR REMOVAL OF DEBRIS ACCUMULATED BY EACH TRADE. HOWEVER, EACH TRADE WILL KEEP THE JOB SITE CLEAN AND SAFE AT ALL TIMES, ALONG WITH A
BROOM FINISH AT THE END OF EACH WORKING DAY.
16. IF CHANGES ARE MADE IN THE FIELD ON THIS PROJECT VIA DIMENSIONS, MATERIALS, INSTALLATION DIFFERENT THAN INDUSTRY TECHNIQUES AND STANDARDS, ETC., "CONSTRUCTION MANAGER" IS TO BE NOTIFIED 48 HOURS IN ADVANCE TO THESE CHANGES
TO BE MADE BY SAID TRADE. IF NOTICE IS NOT GIVEN TO THE C.M., THEN THAT SUBCONTRACTOR IS TOTALLY RESPONSIBLE FOR THE CONSEQUENCES AND EFFECTS EVOLVED FROM THESE CHANGES.
17. CONSTRUCTION CLEAN-UP: AFTER ALL OTHER WORK IS COMPLETED AND JUST PRIOR TO TURNING THE SPACE OVER TO THE OWNER, THE CONSTRUCTION MANAGER WILL EMPLOY THE SERVICES OF A PROFESSIONAL CLEANING SERVICES TO CLEAN AND WASH
DOWN ALL INSTALLED EQUIPMENT, SERVICE AREAS, ALONG WITH THE CLEANING OF ALL GLASS WINDOW/DOOR SURFACES PRIOR TO OCCUPANCY. ALL WORK SHALL CONFORM TO THE APPLICABLE CODES FOR THIS MUNICIPALITY. SEE 'CODE REVIEW' ON
THIS SHEET.
18. DO NOT SCALE DRAWINGS.
19. CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK AT ANY TIME WITHOUT APPROVED CONTRACT DOCUMENTS.
20. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL ARCHITECTURAL, MECHANICAL, TELEPHONE, ELECTRICAL (INCLUDING LIGHTING), AND PLUMBING SO TO ENSURE THAT REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ALL EQUIPMENT
ARE PROVIDED.
21. DIMENSIONS SHALL NOT BE CHANGED WITHOUT THE ARCHITECTS WRITTEN APPROVAL.
22. CONTRACTOR TO PROTECT EXISTING CONSTRUCTION AND RESTORE ALL FINISH SURFACES TO THEIR ORIGINAL CONDITION WHERE DAMAGED.
PROJECT LOCATION
NO SCALE
,jasmine rnangonan urui
T
St 531fith S3t51hSt
Nara Villag-e
i
LansC rsf=�rs To wn
gtrare Park
83161hPI
KamKdrlg S3q}
Lre II BBQ Grill Buffet : ru
N
Trader Joe's 19 q0
I
i Batteries Plus Bulbs
,Mexican Grill I BstlErrstole
Harbor Freigill Tp.6Is19
I
SJ
f 5 3"th St
I
Chick-fil-A9
SEATAC VILLAGE SHOPPING CENTER
FEDERAL WAY, WA 98003
IPT.J Maxx
S 31 S[h P!
SeaTac Village
Shopping Center
cw Beauty Red Lobster 19
C'�9m _litj s7UK
9 Center Plaza
S32uzh St S 32M St
KEY PLAN
NO SCALE
1706 S. 320th STREET
SUITE J
rader
HatneGood o Dsw
T.J. MB!lSiL BIG
❑
S 324TH ST
1;xr A
RECEIVED
Nov 15 2022
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
4_0
U
00
U
or)
i
Q
Q
�
dj
E:
O
M�
W
a
U
U
Z
>
�
cfl
ti
_
m
0
O
C)
L0
ti
�
O
"!
2i
CV
O
_
CO)
M
O
MO
W
M
Q
LLJ
Z
LU J
�Un Q/
V 0!.
c0 z w
CV � C)
COLLJ
LL.
lk O 1
W W w
LU
Q ::D^^
�
v J
U J --
U w
W
LLJ _40
W O
CV
M
V J
(-0
O
ti
IV -
PROJECT NUMBER:
WJA-22077
PERMIT REVIEW
10-18-2022
I REVISIONS L I
COVER SHEET
CS-1
SHEET 1 OF 10
,► CITY" PERMIT APPLICATION
�
PER
Federal Way MIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003 6325
253-835-2607 + FAX 253-835-2609 + permiteenterCcltyoffederalway com
PERMIT NUMBER _
- � TARGET DATE
SITE ADDRESS 1
1�7 a& u40(-% 6.5""T'C'
SUITE/UNIT
PROJECT VALUATION
ZONING
ASSESSOR'S TAX/PARCEL I
$ (V1000. 00
G G
_o _!i- a,_L
TYPE OF PERMIT
P1 BUILDING ® PLUMBING JO MECHANICAL 0 DEMOLITION 11 ENGINEERING ❑ FIRE PREVENTION
NAME OF PROJECT
Cl a-t r -r- IS
T + P.YIty
PROJECT DESCRIPTION
Detailed description of work to
i new
`i .•
I
be included on this permit only
LJ
NAME 60._r 1 1
Ci
PRIMARY PHONE
PROPERTY OWNER
MAILING ADDRESS
E-MAIL
CITY w
w� ZIP
g8005
NAME
PHONE
MAILING ADDRESS
E-MAIL
CONTRACTOR
CITY
STATE
ZIP
FAX
WA STATE CONTRACTOR'S LICENSE
EXPIRATION DATE
UBI
NAME ,
rl W 1 - 1Ntt�rrcvl 0hr+ h cki
PRIMARY PHONE
T- 59 - 9 Gi
MAILING ADDRESS
rsQl 5-rr
E-MAIL
lal1k� ox-c6 • f'c IV
APPLICANT
� L (' h
/A. _ . tV / VNMre 5
CITY STATE
alR.�ine. TL_
ZIP
0041
FAX
$459-9441
PROJECT CONTACT
NAME
Karr1 O'k - YU6YCtA 506nsW% Acrt 1
MARY PHONE
-7 - 3-rq _ 11el �
MAILING ADD _ _ I 1
« 57'r eA+
(The individual to receive and
respond to all correspondence
r
CITY STATE
al'Jrut, z>r
ZIP
!s o 0 uI
FAX
Ml- 351- 4 441
concerning this application)
PROJECT FINANCING
NAME L
• �� S S'
OWNER -FINANCED
When value is $5,000 or more
IRCW 19.27 0951
MAILING ADDRESS, CITY, STATE, ZIP
1,40 a W • C"+V mil s
PHONE
e Orr - 7(,s - 7-D54
I certify under penalty of perjury that I am the property owner or authorised agent of the property owner. I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit. I understand that the
Issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental taws.
I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in
the investigation and defense of such claim), which may be made by any person, including the undersigned, and flied against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
h1formation supplied to the city as apart of t1h`istappQliccation�
SIGNATURE: ' DATE
PRINT NAME: 1 •► L=&M�i S
Bulletin #100 February 19, 2020 Page 1 of k:'.Ilandouts%Permlt Application
12
VALUE OF MECHANICAL WORK
MECHANICAL PERMIT
$
00o.00
Indicate holy many o each type o
ucture to be installed or relocated as
part of this project, Do not include exisang inures to remain.
AIR HANDLING UNITS
FANS
GAS PIPE OUTLETS
OTHER IDweribe)
AIR CONDITIONER
FIREPLACE INSERTS
HOODS Ico,m. -w)
BOILERS
FURNACES
HOT WATER TANKS Ica.,
COMPRESSORS
GAS LOG SETS
REFRIGERATION SYST
DUCTING
GAS PIPING
WOODSTOVES
VALUE OF PLUMBING WORK
PLUMBING PERMIT
1$2-000-bo
Indicate how many of each Igoe offixture
to be installed or relocated as Cart
of this project. Do not include existing fixtures to remain.
BATHTUBS
LAVS jif—dSmkej
TOILETS
�_ WATER PIPING
DISHWASHERS
RAINWATER SYSTEMS
URINALS
OTHER (Describe)
DRAINS
SHOWERS
VACUUM BREAKERS
DRINKING FOUNTAINS
SINKS IKAcn,,,:-,-,1,1yl —I—,
WATER HEATERS
HOSE BIBBS
SUMPS
WASHING MACHINES
TOTAL FIXTURE$
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY?
WATER PURVEYOR
SEVER PURVEYOR
VALUE OF EXISTING IMPROVEMENTS
$ wwk,+tiewn
EXISTI((N��G/PREVIOUS USE
LOT SIZE IlnSquere Feetl
EXISTING FIRE SPRINKLER SYSTEM?
PROPOSED FIRE SUPPRESSION SYSTEM?
y1% 1,yk455
(40 +11; `
Yes X No
; , Yes X No
RESIDENTIAL -NEW OR ADDITION
AREA DESCRIPTION (in square feetl
EXISTING
PROPOSED
TOTAL
FOR OFFICE USE
BASEMENT
FIRST FLOOR (or Mobile Home)
SECOND FLOOR
COVERED ENTRY
DECK
GARAGE 0 CARPORT L]
OTHER (describe)
Area Totals
E1dSTWO
PROPOSED
'TOTAL
"NEWHOMM ORLY"e
ESTIMATED SELLING PRICE $
1 # OF BEDROOMS
COMMERCIAL - NEWADDITION
AREA DESCRIPTION
Area in
S are Feet
Occupancy Grouplsl
Construction
# of
Stories
Additional Information
NBW BumviN(o
ADDITION
COMMERCIAL - REMODEUTENANT IMPROVEMENTS
AREA DESCRIPTION
Area in
Square FeetType
Occupancy Group(s)
Construction
0 of Stories
Additional Information
TOTAL BUILIDEla
� S�'
#Vk-x4Af/ &S
TENANT AREA ONLY
I /�, ^��
M •w C&1„r4y' 1,&
1
PRO.fEC1 AREA ONLY
22
( � - 1
Bulletin 000 February 19, 2020 Page 2 of 2 k: Handouts Permit Applic mon