Loading...
23-102014, A • City of Federal Way Community Development Dept, 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Building - Single Family Y Permit #:23-102014-00-SF Inspection Request Line: (253) 835-3050 Project Name: SOUTH CAMPUS ESTATES LOT 4 Project Address: 521 SW 366TH ST Parcel Number: 787965 0040 Project Description: BLUEBEAM - Construction of a 3269 square foot 2-story single family residence with a 251 square foot covered entry and a 1137 square foot attached garage. Includes plumbing and mechanical. Owner Applicant Contractor Lender SOUTH CAMPUS DEVELOPMENT RUSS SORKNESSJK MONARCH J K MONARCH LLC OWNER IS LENDER LLC LLC PO BOX 188 PP BOX 188 PO BOX 188 PUYALLUP WA 98371 PUYALLUP WA 98371 PUYALLUP WA 98371 Census Category: 101 - New Single Family House Includes: # 1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 3,269.00 Additional Permit Information New / Additional Sq. Feet - Ist Floor ..................... 2106 New / Additional Sq. Feet - 2nd Floor.................... 1 163 New / Additional Sq. Feet - 3rd Floor ..................... 0 Occupancy 41 - Area (Sq. Feet).............................. 3269 New / Additional Sq. Feet - Basement .................... 0 Basic Plan?........................................................... No Occuanc# I -Construction "fe.................:. P Y YP .••••. Type V - B New / Additional Sq. Feet - Deck..........:............... 0 New / Additional Sq. Feet - Garage ........................ 1137 Mechanical to be Included? .................................... Yes Plumbing Work Valuation? ..................................... 20000 Mechanical Work Valuation?..................... ........ ,. 15000 Number of Stories ................................................... 2 New / Additional Sq. Feet - Other .................... I...... 251 Plumbing to be Included? ........................................ Yes New / Additional Sq. Feet - Total........................... 4657 Will Certificate of Occupancy be Issued? ............... Yes Occupancy #1 - Use........................ ........................ Residence (1 or 2 family) Comprehensive Plan Designation............... ... SF - Medium Density Zoning Designation.......................... ....................... RS 15.0 Residential Total Valuation: 603,700.91 Air Handling Units Fans Gas Piping Bathtubs Lavatories Water Closets is Mechanical Fixtures 1 Air Conditioners - Stand Alone 1 Ducting 6 Fireplace Inserts 1 Furnaces I Gas Pipe Outlets 3 Plumbing Fixtures 2 Dishwashers 1 Laundry Washer Outlets 5 Showers Si lEs-- 3 Water Heaters- Hose Bibbs CONDITIONS:. FIRE APPROVAL CONDTIONS: 1. Installation of an automatic fire sprinkler system is NOT REQUIRED. 2. Demolition and construction shall conform to the requirements of Intel Fire Code 1 1 2 3 Chapter 33. 3. An approved carbon monoxide alarm must be installed outside of the each separate sleeping area, in the immediate vicinity of the bedroom(s) within homes with fuel -fired appliances and/or attached garages. (IFC 908.7 as amended by the State of Washington) PUBLIC WORKS APPROVAL CONDITIONS: All work must be done per „;rant Middleton PE designed on 11-21-2022. PERMIT EXPIRES Wednesday, 27 December, 2023 Permit Issued on Friday, June 30, 2023 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washin ton and the City of Federal Way Owner or agent: F Date City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: SOUTH CAMPUS ESTATES LOT 4 Address: 521 SW 366TH ST Includes: #1 #2 #3 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 3,269.00 Owner Name: SOUTH CAMPUS DEVELOPMENT LI Owner Address: PO BOX 188 PUYALLUP WA 98371 a� " Building Official Permit # 23-102014-00-SF #4 lfil'7,0 z*-- Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. CITY OF; Federal Way THIS CARD IS TO REMAIN ON -SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 L PERMIT #: 23 102014 00 Address: 521 SW 366TH ST Project: SOUTH CAMPUS DEVELOPMENT l FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. 0 SWM Precon Site Mtg (4400) Site Assessment (Erosion) (4365) 0 Footings/Setback (4110) Approved To be done PRIOR to breaking ground Approved to place concr to By Date By Date By G Date ® Foundation Wall (4115) Drainage/Downspout (4040) © Plumbing Groundwork (4190) Approved to place concrete �1' Approved to backfill Approved to cover ` By Date By Date 1I )S L By J o Date?/qu El Slab/Concrete Floor (4255) ® Underfloor Framing (4285) El Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By AO Date $ f )lye By Date t G Shear Walls (4245) 41 Roof Sheathing (4220) '' Rough Plumbing (4230) Approved to install siding Approved to install raoQfi� Approved �b By Date y By Date By Date t Mechanical Rough -in (4165) 14 Gas Piping (4125) 0 Fire/Draft Stops (4095) Approved Approved to release test Approved By 1, 1-2> Date 0 $ a3 By Date a a'� By L p Date tv X3 Interim Erosion Control (4370)EandFire/Dra scheduling a Framing inspection; 9 7 Framing (4120) Approved Plumbing & Mechanical Rough -in Approved to insulate ft Stop inspections mustbe signed -By and approved. IBC 109.3.4 By L Date A 3 Date t8 Insulation (4150) 19 Gypsum Wallboard Nailing (4130) 2J Final Erosion Control (4375) Approved to install wallboard Approved to install mud & tape Approved By Date IV ZI2 a By L 13 Date I& A 7 By Date P1 Final - Mechanical (4065) t' Final -Plumbing (4075) 23 Final - Building (4050) Approved Approved Approved By Date I Z¢ By Date (I L4— By IY4L Date El Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date I By Date CITY OF 1Federal Way Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Prone 253-835-2607 Fox 253-835-2609 CORRECTION NOTICE ADDRESS: S2-1 _S w PERMIT#: Vey ff4 VAVN­r_ � moteo, 4-1-- -4- v'4u&c.r =--v r-1 Fc rr' ILL 2<3-loza4- IF YOU HAVE QUESTIONS CALL V � l — (253) 835-__s4_1:1 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. —_ ( 1�1" --- —gA — --- --- DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of - _ _ OF viz� Federal Way Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: _5al SW� 366'f`' S'r PERMIT#: 93-10').01�� ' s v -f e-Ci 2'rru i IF YOU HAVE QUESTIONS CALL L9v (253) 835- R&2-1 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS.(NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. !vz-q /a3 DATE INSPECTOR EEO NOT REMOVE THIS NOTICE Page of CITY OF Building Division 33325 Eighth Avenue South Fe deral Wa Federal 9$03-6325 Phone 253 83535- 2h07 D7 Fox 253 835 2609 CORRECTION NOTICE ADDRESS: 64�,n�s �I PERMIT#: 65 IZ6 2,01 _ t i �Vx)o IF YOU HAVE QUESTIONS CALL E �4 (253) 835-_ 2 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS, NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of `CITY OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, 48003-6325 Phone 253.835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: VA 'JVJ 50� St PERMIT#: IF YOU HAVE QUESTIONS CALL (253) 835- WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 83 - 050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. ATE INSPECTOR ~ DO NOT REMOVE THIS NOTICE Page of - — _