Loading...
21-102025City of Federal Way Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: LAKEHAVEN - RETAINING WALL Project Address: 31627 1ST AVE S Project Description: BLUEBEAM - Construction of a retaining wall. Building - Commercial Permit #:21-102025-00-CO Inspection Request Line: (253) 835-3050 Parcel Number: 0721049017 Owner Applicant Contractor Lender LAKEHAVEN WATER & SEWER MELENA STEWARTHELIX LYDIG CONSTRUCTION INC OWNER FINANCED DISTRICT DESIGN GROUP 3180 139TH AVE SE 31627 1ST AVE S 6021 12TH ST E SUITE 201 BELLEVUE WA 98005 FEDERAL WAY WA 98003 TACOMA WA 98424 Census Category: 437 - Commercial alt / add / conversion Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area (sq. ft.) Additional Permit Information Mechanical to be Included? ..................................... No Is this an Online or O.T.C. application? .................. No Plumbing to be Included? ................................,.......... No Total Valuation: 600,000.00 Number of Stories ................................................... I Permit for Building Shell Only? .............................. No No Fixtures Associated With This Permit II CONDITIONS: No tie -backs or other type of wall supports shall be extended into the City's Right of Way. PERMIT EXPIRES Tuesday, 9 August, 2022 Permit Issued on Wednesday, August 11, 2021 hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: F INA. !-.ED Date: CITY OF - Federal Way THIS CARD IS TO REMAIN ON -SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 21 102025 00 Address: 31627 1ST AVE S Project: LAKEHAVEN WATER & SEWER D] FEDERAL WAY WA 98003-5201 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CART]. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. Q Site Assessment (Erosion) (4365) ® Footings/Setback (4110) ® Foundation Wall (4115) To be done PRIOR to breaking ground Approved to piaee concrete Approved to place concrete By Date By Date By Date ® Drain age[Downs pout (4040) ® Re -steel (4215) ® Slab/Concrete Floor (4255) Appravcd to backfill Approved to place concrete or grout Approved to place concrete By Date By Date By Date l! 1 Underfloor Framing (4285) ® Floor Sheathing (4105) ® Shear Walls (4245) Approved to sheath floor Approved to install flooring Approved to install siding By Date By Date By Date 10 Roof Sheathing (4220) Fire/Draft Stops (4095) 1 Interim Erosion Control (4370) Approved to install roofing Approved Approved By Date By Date By Date Prior to scheduling a framing inspection, i 13 Framing (4120) Insulation (4150) Electrical, Phjubing & klethanical Rough -in and Firdf)rjift Stop inspections must be sirned- Approved to insulate Approved to install wallboard off and approved. 18C 109.3.4 By Date By Date 7s Gypsum Wallboard Nailing (4130) 16 Suspended Ceiling Grid (4265) Final - S K F & R (4060) Approved to install rnud & tape Approved to drop tile Approved By Date By Date By Date 98 Final - Planning 19 Final - Public Works (4080) 20 Final Erosion Control (4375) Approved Approved Approved By Date By Date By Date 21 Final - Building (4050) BY ` - Approved J Date 1 G� Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date