Loading...
23-101338City of Federal way Community Development Dept, 33325 Sth Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name Project Address Project Description THE WOODLANDS AT REDONDO CREEK LOT 23 1940 S 301 ST CT Building - Single Family Permit #:23-101338-00-SF Inspection Request Line: (253) 835-3050 Parcel Number: 952651 0230 BLUEBEAM - Construction of a 2335 square foot, 2-story, single family residence with a 90 square foot covered entry, 216 square foot deck and an attached 395 square foot garage. Includes plumbing and mechanical. Owner Applicant Contractor Lender SSHI LLC DBA D R HORTON JESS BOSANCUD R HORTON D R HORTON OWNER IS LENDER 1 t241 SLATER AVE NE SUITE 12C 11241 SLATER AVE NE SUITE 120 11241 SLATER AVE NE SUITE 120 - KIRKLAND WA 98033 KIRKLAND WA 98033 KIRKLAND WA 98033 Census Category: 101 - New Single Family House Includes: # 1 #2 43 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (s.. ft.) 2,335.00 Additional Permit Information New / Additional Sq. Feet - Ist Floor .................... 903 New / Additional Sq. Feet - 3rd Floor ..................... 0 New / Additional Sq. Feet - Basement .................... 720 Occupancy #I - Construction Type..._._...- , Type V - B New / Additional Sq. Feet - Garage....... .................. 373 Plumbing Work Valuation? ....................... ...........:..,; 20000 Number of Stories ............... 2 Plumbing to be Included? ....................................... Yes Will Certificate of Occupancy be Issued? ............... Yes Comprehensive Plan Designation .................... ...... SF - Higlt-Density Residential New / Additional Sq. Feet - 2nd Floor .................... 1 162 Occupancy 41 - Area (Sq. Feet) .............................. 2335 BasicPlan? ............. .:....... .:»....... ...:...................... No New / Additional Sq. Feet - .............. 140 Mechanical to be Included? ..................................... Yes Mechanical Work Valuation?..... ...... ................. 20000 New / Additional Sq. Feet - Other..... ........ ............ 1 0 New / Additional Sq. Feet - Total ........................... 3298 Occupancy #1 -Use ..............................-.-...-........... Residence (1 or 2 family) Zoning Designation ................................................. ...................... . RS 5.0 Total Valuation: 413,543.81 """'w Mechanical Fixtures Fans 6 Furnaces 1 Gas Piping i Gas Pipe Outlets 2 Plumbing Fixtures Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1 Lavatories 4 Showers 2 Sinks 1 Water Closets 3 Water Heaters 1 Hose Bibbs 2 CONDITIONS: Permit information to be verified before issued. Square footage of floors were inaccurate and have been adjusted. Remaining information to be checked. PERMIT EXPIRES Monday, 29 January, 2024 Permit issued on Wednesday, August 2, 2023 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of - T __nd ity of Federal Way. Owner or agent: Date: City of Federal Way Certificate of occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: THE WOODLANDS AT REDONDO CREEK LOT Address: 1940 S 301ST CT Includes: # 1 #2 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 2,335.00 Owner Name: SSHI LLC DBA D R HORTON Owner Address: 11241 SLATER AVE NE SUITE 120 KIRKLAND WA 98033 ku�G 41-,& Building O icial #3 Permit # 23-101338-00-SF #4 TtZOZ-4- Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. CITY OF Federal Way Project: THIS CARD IS TO REMAIN ON -SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 23 101338 00 SSHI LLC dba D R HORTON Address: 1940 S 301ST CT FEDERAL WAY WA 98003 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. 0 SWM Precon Site Mtg (4400) 0 Site Assessment (Erosion) (4365) 0 Footings/Setback (4110) Approved To be done PRIOR to breaking ground Approved to place concrete By Date By Date By Date Foundation Wall (4115) 0 Drainage/Downspout (4040) 0 Pi mbing Groundwork (41 0) By Approved to place concr to Date q By Approved to backfill Date ,.- proved to Cover 7 By Date .7 0 Slab/Concrete Floor (4255) ® Underfloor Framing (4285) Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By rJ Date if Z3 By G, Date �p� By L Date P11C 2S 1t7 Shear Walls (4245) Approved to install siding Roof Sheathing (4220) Approved to install rooting 12 Rough Plumbing (4230) Approved By Date Jp 1� By G Date 1p % �l By .� Date 13 Mechanical Rough -in (4165) 14 Gas Piping (4125) Fire/Draft Stops (4095) By Approved i(r Date 11,34213 . By Approved to release test E Date f a13l�Z�j By Approved ` Date G Interim Erosion Control (4370) Prior to scheduling a Framing inspection; 17 Framing (4120) Approved and Electrical, Plumbing & Mechanical Rough -in Fire/Draft Stop inspections must be signed - Approved to insulate By Date off and approved. IBC 109.3.4 By Date 1i3 Insulation (4150) 19 Gypsum Wallboard Nailing (4130) 21] Final Erosion Control (4375) Approved to install wallboard Approved to install mud & tape Approved By ,o-A) Date i (113 JZ3 By Go Date It Ill z.5 By Date va� El Final - Mechanical (4065) 0 Final - Plumbing (4075) 23 Final - Building (4050) Approved Approved Approved By yxk Date L 11,4 By Date I j� i3 IZ� By Date Rough Electrical Final Electrical ❑ Right of Way Approved Approved Approved By Date By Date By Date A CITY OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, Fax 98003-6325 y Phone 253-835-2607 Fax 253-35-609 CORRECTION NOTICE ADDRESS: PERMIT j 3316 tFb e S rFaK— 13 W C_MK� IF YOU HAVE QUESTIONS CALL W' (253) 835- 1/6L[ WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of CITY OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, x 98003-6325 y Phone 253-835-2607 Fax 253-35-609 CORRECTION NOTICE ADDRESS: PERMIT#:� U�_ a�� a IF YOU HAVE QUESTIONS CALL (253) 835- WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. q� 20 - — � \ � DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of CITY OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, 98003-6325 y Phone 253-835-2607 Faxx 253-835835-2609 CORRECTION NOTICE ADDRESS: 19 q6 15. WC �If_ CT_ PERMIT#:_?�� - 10 (35 1�1 -13 0 IF YOU HAVE QUESTIONS CALL 1 OAd (253) 835-� WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of