22-102345 (2)ABBREVIATIONS
ABBREVIATIONS
PROJECT INFORMATION
AB
ANCHOR BOLT
LK
LOCKERS
PROJECT NAME
CRESTVIEW WEST APARTMENTS -
ACOUS
ACOUSTIC
MAS
MASONRY
BUILDING 7
ACT
ACOUSTICAL CEILING TILE
MAT
MATERIAL
PROJECT SCOPE
BUILDING REPAIRS
AFF
ABOVE FINISHED FLOOR
MAX
MAXIMUM
PROJECT LOCATION
27912 PACIFIC HWY S, FEDERAL
ALUM
ALUMINUM
MECH
MECHANICAL
WAY WA 98003
ARCH
ARCHITECTURAL
MED
MEDICINE
AT
ACOUSTIC TILE
MET
METAL
ZONING JURISDICTION
CITY OF FEDERAL WAY
AUTO
AUTOMATIC
MET STD
METAL STUD
SITE USE
MULTI -FAMILY
BITUM
BITUMINOUS
MFR
MANUFACTURER
BL
BORROWED LIGHT
MIN
MINIMUM
BLDG
BUILDING
MISC
MISCELLANEOUS
BLK
BLOCK
ML
METAL LATH
CODE ANALYSIS
BM
BEAM
MTD
MOUNTED
BOT
BOTTOM
MW
MILLWORK
CODE:
20181EBC
CAB
CABINET
N
NORTH
OCCUPANCY CLASSIFICATION:
3 STORY (APARTMENTS)
CC
CUBICLE CURTAIN
NIC
NOT IN CONTRACT
CONSTRUCTION TYPE:
EXISTING
CEM
CEMENT
NO
NUMBER
BUILDING TYPE:
3 STORY (APARTMENTS)
CG
CORNER GUARD
NOM
NOMINAL
FIRE SPRINKLERS: (APARTMENTS)
N/A
CJ
CONTROL JOINT
NTS
NOT TO SCALE
BASE ALLOWABLE AREA (APARTMENTS): EXISTING
CL
CLG
CENTER LINE
CEILING
02
OC
OXYGEN
ON CENTER
ALLOWABLE HEIGHT:
BUILDING AREA:
3 STORIES
EXISTING
CLOS
CLOSET
OD
OUTSIDE DIAMETER
CLR
CLEAR
OH
OPPOSITE HAND
CMU
CONCRETE MASONRY UNIT
OPNG
OPENING
Co
CASED OPENING
PL
PLATE
DAMAGE SQ.
FT. PERCENTAGE
COL
COLUMN
PLAS
PLASTIC LAMINATE
CONC
CONCRETE
PLAS
PLASTER
CONT
CONTINUOUS
PLMB
PLUMBING
CONTR
CONTRACT OR CONTRACTOR
PTN
PARTITION
CSS
CLINICAL SERVICE SINK
R
RUBBER
CT
CERAMIC TILE
RAD
RADIUS
CTR
COUNTER
RD
ROOF DRAIN
CTR
COUNTER FLASH
RECP
RECEPTACLE
FLASH
REF
REFERENCE
Area Description (in Gross SF)
Damaged*
Undamaged
Total (Sq Ft)
First Floor (Units, Corridor, Stairwells)
2,247
7,330
9,577
Second Floor (Units, Corridor, Stairwells)
3,751
5,816
9,577
Third Floor (U nits, Corridor, Stairwells)
3,026
5,551
9,577
AREA TOTALS
9,034
19,597
29,731
Percent cf Building damaged
31%
DET
DETAIL
REFRIG
REFRIGERATOR # Damage defined asfocations where drywnff kunsremoved due tofire, kvQier vrsmvke dQmage (damage exceeding Cos],
DIA
DIAMETER
REINF
REINFORCE
DIM
DIMENSION
READ
REQUIRED
DIS
DISPENSER
RESIL
RESILIENT
DN
DOWN
REV
REVISION
DWG
DRAWING
RM
ROOM
EA
EACH
S
SLIDE
EJ
EXPANSION JOINT
S/S
SERVICE SINK
EL
ELEVATION
SC
SOLID CORE
ELEC
ELECTRIC
SCH
SCHEDULE
ELEV
ELEVATOR
SECT
SECTION
EQ
EQUAL
SERV
SERVICE
EQUIP
EQUIPMENT
SHT
SHEET
EXIST
EXISTING
Sim
SIMILAR
FD
FLOOR DRAIN
SL
SLIDING
FDN
FOUNDATION
SM
SHEET METAL
FEC
FIRE EXTINGUISHER CABINET
SNK
SINK
FHC
FIRE HOSE CABINET
SPEC
SPECIFICATIONS
FHV
FIRE HOSE VALVE
SQ
SQUARE
FIN
FINISH
SS
STAINLESS STEEL
FL
FLOOR
STD
STANDARD
FLASH
FLASHING
STL
STEEL
FR
FRAME
STORE
STORAGE
FT
FEET OR FOOT
STR
STRUCTURAL
FTG
FOOTING
SUSP
SUSPEND
FURR
FURRING
T/C
TOP OF CURB
GA
GAUGE
TB
TACKBOARD
GALV
GALVANIZED
TEL
TELEPHONE
GL
GLASS
THK
THICK
GYP BD
GYPSUM BOARD
TK
THICKNESS
HC
HOLLOW CORE
TOIL
TOILET
HFS
HALF FULL SIZE
TRANS
TRANSFORMER
HM
HOLLOW METAL
TV
TELEVISION
HORIZ
HORIZONTAL
TYP
TYPICAL
HT
HEIGHT
UL
UNDERWRITERS
HTG
HEATING
LABORATORIES
ID
INSIDE DIAMETER
UNO
UNLESS OTHERWISE NOTED
IN
INCH
V
VINYL
INCL
INCLUDED
VB
VIEW BOXES
INFO
INFORMATION
VCT
VINYL COMPOSITION TILE
INSUL
INSULATION
VERT
VERTICAL
INT
INTERIOR
VEST
VESTIBULE
JC
JANITOR CLOSET
VIF
VERIFY IN FIELD
JT
JOINT
W
WIDTH
LAM
LAMINATED
W/
WITH
LAT
LAY -IN ACOUSTICAL TILE
W / O
WITHOUT
LAV
LAVATORY
WC
WHEELCHAIR
WC
WATER CLOSET
WD
WOOD
WP
WATERPROOF
MIT
WEIGHT
WWF
WIELDED WIRE FABRIC
SYMBOLS LEGEND
1 SIM
A101 BUILDING SECTION
SIM
1
A101 CALLOUTS
DENOTES VISUAL AND
HEARING IMPAIRMENT
EQUIPPED UNITS
Ref MATERIAL LEGEND
1
EXTERIOR ELEVATIONS EARTH
A101
AGGREGATE/POROUS
CONCRETE
CEMENT / CONCRETE UNDERLAYMENT
CONCRETE ASPHALT
RIGID INSULATION
BATT INSULATION
CRESTVIEW WEST
BUILDING 7
PROJECT TEAM
OWNER
CONTRACTOR
27912 PACIFIC HWY S, FEDERAL ARCHITECT
WAY, WA 98003
SHEET INDEX
SHEET # SHEET NAME REV. # REV. DATE
1.GENERAL
G001 COVER SHEET
&ARCHITECTURAL
A100
SITE PLAN
A101
OVERALL FLOOR PLANS - LEVEL 1
A102
OVERALL FLOOR PLANS - LEVEL 2
A103
OVERALL FLOOR PLANS - LEVEL 3
A200
ENLARGED UNIT PLANS
A400
ELEVATIONS
FLOOR / CEILING RATED ASSEMBLY
1-HR. RATED FLOOR/CEILING ASSEMBLY (UNIT/UNIT)
GA FILE NO. FC 5529 GENERIC EXISTING 2
WOOD JOISTS, GYPSUM WALLBOARD
BASE LAYER: LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES
TO
2 X10 WOOD JOISTS 24" O.C. WITH 1-1/4" TYPE W OR S SCREWS 24" O.C.
FACE LAYER: 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED
AT RIGHT ANGLES TO JOISTS WITH 1-7/8" TYPE W OR S SCREWS 12" O.C. AT JOINTS
AND INTERMEDIATE JOISTS AND 1-1/2" TYPE G SCREWS 12" O.C. PLACED 2" BACK ON
EITHER SIDE OF END JOINTS. WOOD JOISTS SUPPORTING 1/2" PLYWOOD WITH
EXTERIOR GLUE APPLIED AT RIGHT ANGLES TO JOISTS WITH 8D NAILS.
JOINTS OFFSET 24" FROM BASE LAYER JOINTS.
RATED WALL ASSEMBLIES
1-HR. RATED WALL ASSEMBLY
CALCULATED FIRE RESISTANCE PER IBC SECTION 722.6.2.3,
TABLE 722.6.2(1) & TABLE 722.6.2(2)
GA FILE WP 3371 - RATED CORRIDOR WALL ASSEMBLY
FIRE DESIGN:
ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED PARALLEL
OR AT RIGHT ANGLES TO EACH SIDE OF 2X4 WOOD STUDS 16" O.C. STAGGERED 8" O.C. ON
2X6 WOOD PLAYES WITH 2" TYPE W SCREWS 7" O.C. MINIMUM 3-1/2" GLASS FIBER BATTS. 0.80
PCF, WOVEN IN CAVITY.
HORIZONTAL BRACING REQUIRED AT MID -HEIGHT. (LOAD BEARING)
E - 5/8" TYPE X GYPSUM WALLBOARD
J - 2X6 WOOD WALL STUDS
H - 2X4 STUDS STAGGERED
GA FILE WP 3510 - RATED UNIT WALL ASSEMBLY
FIRE DESIGN:
ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED PARALLEL
OR AT RIGHT ANGLES TO EACH SIDE OF 2X4 WOOD STUDS 24" O.C. WITH 6D COATED NAILS,
1-7/8" LONG, 0.0915" SHANK, 1/4" HEADS, 7" O.C.
JOINTS STAGGERED 24" ON OPPOSITE SIDES. (LOAD BEARING)
E - 5/8" TYPE X GYPSUM WALLBOARD
J - 2X4 WOOD WALL STUD
G - 2X4 WOOD STUDS
GA FILE WP 3370 - RATED UNIT PARTY WALL ASSEMBLY
FIRE DESIGN:
ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED PARALLEL
OR AT RIGHT ANGLES TO EACH SIDE OF DOUBLE ROW OF 2X4 WOOD STUDS 16" O.C. ON
SEPERATE PLATES 1" APART WITH 2" TYPE W SCREWS 7" O.C. TWO LAYERS 3.51, UNFACED
GLASS FIBER INSU LATION FRICTION FIT ON BOTH SIDES.
JOINTS STAGGERED 16" ON OPPOSITE SIDES. HORIZONTAL BRACING REQUIRED AT MID -
HEIGHT. (LOAD BEARING)
E - 5/8" TYPE X GYPSUM WALLBOARD
J - 2X4 WOOD WALL STUD
G - 2X4 WOOD STUDS
1-HR. RATED WALL ASSEMBLY (EXTERIOR. FIRE -SIDE AT INTERIOR
CALCULATED FIRE RESISTANCE PER IBC SECTION 722.6.2.3,
TABLE 722.6.2(1) & TABLE 722.6.2(2)
1. EXTERIOR FINISH:
SIDING PER EXTERIOR ELEVATIONS
2. EXTERIOR SHEATHING:
5/16" MIN. WOOD STRUCTURAL PANEL W/ EXTERIOR GLUE.
3. FRAMING:
2x4 WOOD STUDS AT 16" O.C. STUD CAVITY FILLED W/ GLASS FIBER INSULATION.(20 MIN. + 15
MIN.)
4. INTERIOR FINISH:
5/8" TYPE X GYPSUM WALLBOARD
EXISTING CONCRETE EXISTING PLYWOOD
NEW R13 BATT
INSULATION FOR SOUND
u u
El ID
INTERIOR
- ALL NEW UNIT ENTRY DOORS TO BE 20 MIN.
W/ LEVER HARDWARE.
ALL NEW WINDOWS TO BE 0.30 U-VALUE ( TABLE R402.1.1)
ALL NEW EXTERIOR DOORS TO BE 0.30 U-VALUE
ANY OPENED EXTERIOR WALLS TO BE FILLED TO THE EXTENT POSSIBLE
W/ BATT INSULATION.
STRUCTURAL ENGINEER
CRESTVIEW WEST PARTNERS, LP
17786 DES MOINES MEMORIAL DR.
BURIEN, WA 98184
PHONE: 206.241.4800
CONTACT:SEAN MCKENNA
EMAIL: SEAN@FARRELLPI.COM
COMMERCIAL RESTORATION COMPANY
7310 S ALTON WAY, BUILDING 6 SUITE K
CENTENNIAL, CO 80112
PHONE: 720.338.2707
CONTACT: SAM JACK
EMAIL: S.jack@crcmaii.com
ROSS DECKMAN & ASSOCIATES, INC.
207 4TH AVE. S.E.
PUYALLUP, WA. 98372
PHONE: 253.840.9405
CONTACT: BILL BOWDISH
EMAIL: bill@rdarchitect.com
CT ENGINEERING
180 NICKERSON STREET SUITE 302
SEATTLE, WA 98109
PHONE: 206.285.4512
CONTACT: CRAIG ROBERTS
EMAIL: CROBERTS@CTENGINEERING.COM
RECEIVED
May 24 2022
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
R D+A
ROSS DECKMAN & ASSOCIATES INC.
207 FOURTH AVENUE SOUTHEAST,
PUYALLUP, WASHINGTON 98372
PHONE: 253 . 840. 9405
FAX 253 . 840 . 9503
,8892'5EREGISTERED
CHITECT
?ILLIAM BOWDISH
ATE OF WASHINGTON
SUBMITTAL SET
05/19/2022
co
O
O
00
Q
Z�
0
J
J Q
LIJ
M�
LLI
F_ LL
V♦
W
>= W
W
U _
W
LL
> U
I.— Q
cn 0 W
W C\j >
T
CF) O
U
LL1
V N V
w
0
U
U)
w
0
APPROVAL STAMPS
JOB NO.:
2207
ISSUE DATE:
05/19/2022
REVISED:
DRAWN BY:
CG
SHEET
G001
5/19/2022 2:32:11 PM
lz
01
I N V I-9 1 n
OVERALL SITE PLAN
1 " = 40'-0"
KEYNOTES
# DESCRIPTION
RECEIVED
May 24 2022
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
R D+A
ROSS DECKMAN & ASSOCIATES INC.
207 FOURTH AVENUE SOUTHEAST,
PUYALLUP, WASHINGTON 98372
PHONE: 253 . 840. 9405
FAX: 253 . 840 . 9503
8925 REGISTERED
ARCHITECT
?ILLIAM BOWDISH
ATE OF WASHINGTON
SUBMITTAL SET
05/19/2022
co
0
0
00
Q
Z
�
0
J
J Q
— rr
Lu
m o
H H
W
17
W v Z
— LL Q
> Q J
C/)
W N W
a r H
U -
w CV rn
0
w
0
U
U)
w
APPROVAL STAMPS
JOB NO.:
2207
ISSUE DATE:
05/19/2022
REVISED:
DRAWN BY:
CG
SHEET
A100
5/19/2022 2:32:05 PM