Loading...
17-100667RECEIVED CITY OF Federal flay COMMUNITY DEVELOPMENT DEPARTMENT FEB 0 9 2017 33325 8`h Avenue South Federal Way, WA 98003-6325 CITY OF FEDERAL. WAY 253-835-2607; Fax 253-835-2609 CDS www.cilyoffederalway.com SUBSTANTIAL DEVELOPMENT PERMIT EXEMPTION APPLICATION File # J -7 00 �� -7 - 00 - TO BE COMPLETED BY APPLICANT Project Name: -Pez- V, Project Address: s�iz6 S. W • 3 S' Applicant: Mailing Address: l2 5 O o S E. Zo Z°"m Phone Number: Z d 6. 1 l 9. 51.1 O E-mail: r1e [ J C�_ s ( rr [ n e_ Description of Project:. '2 e_b(A; Id 1�S C3T Gt C VL +"i,► ct"F 43A 5 ICJ ►�'�r4 e �u�tr� a 5� o,�►� 7' s a "U -P g_ L[ V-F« ee,ULA l� A-reex. Meets the criteria for exemption under which section of * WAC 173-27-040: *Washington Administrative Code online: a2ps.leg.wa.go Z— /% plicant's Signature Date Bulletin #143 — March 25, 2013 1 of 2 k:\Handouts\Shoreline Exemption TO BE COMPLETED BY STAFF 1) The proposed development is consistent with Section b) of WAC 173-27-040 and is therefore exempt from the Substantial Development Permit Process. 'A. Yes ❑ No (explanatory narrative attached) f orF a C - 2) Proposal requires: Yes No ❑ i Shoreline Variance 01 Shoreline Conditional Use ❑ , R Review, Approval or Permit by other State or Federal Agency -- 3ZA TI 3) Proposal complies with applicable provisions of the City's Shoreline Master Program. Yes ❑ No Condition(s) attached: ❑ Yes ,19. No 2- Y gtQ 4) In accordance with FWRC Section 15.05.,130, this application is hereby: "€J Approved ❑ Denied' 1 �a 2 7 irector, Community Development Date Distribution: X Applicant XL Owner EL File ❑ Outside Agency Bulletin # 143 — March 25, 2013 2 of 2 k:\Handouts\Shoreline Exemption Becky Chapin From: Jeff Reich <reichdesigninc@msn.com> Sent: Wednesday, February 15, 2017 7:56 PM To: Becky Chapin Subject: Re: Wallace Deck Attachments: south 2 jpeg; south 3 jpeg; South looking north jpeg; Southl jpeg; west side looking south jpeg; SE corner looking south jpeg; South 1 from belowjpeg; South 2 from belowjpeg; Resubmittal form.pdf Becky, Thank you for making this process a little easier! Attached are the pictures I have from the home owner. They focus mostly on the southern portion of the deck. The damage occurred I think on the 26th of October and the pictures were taken the next day on the 27th. I've also attached the resubmittal form. Thanks again, Jeff Reich 206.919.5110 ------ Original Message ------ From: "Becky Chapin" <Becky. Chapin @cityoffederalway.com> To: "'reichdesigninc@msn.com"' <reichdesigninc_ msn.com> Sent: 2/14/2017 2:24:32 PM Subject: Wallace Deck Hi Jeff, I'm reviewing the Shoreline Exemption (file # 17-100667-SH) and Building Permit (file # 14-100668-SF) applications for the deck replacement project at 5426 SW 315th St, Federal Way. To expedite the process I'm emailing comments instead of sending out a formal technical comment letter. In order to determine compliance with Federal Way Revised Code (FWRC) 15.05.220(2), Replacement, alteration, or reconstruction of nonconforming use or development, can you provide me with the following information: Pictures of the damaged deck and the date of when the damage occurred. The information can be emailed to me or submitted to the Permit Center with the attached resubmittal form. If you have any questions please let me know. Thanks, Becky Chapin Associate Planner �. Federal Way 33325 8th Avenue South RESUBMITTED FEB 16 2017 Cm' OF FEDErRAI- WAY GOMMUNITY DEVELOPMP� 71 IL rx AT �711 :j -r4 Art, e .�r fo '� J 3 l• �y�y� I bR. lk ..'. kj.& AA i all r I I 7 t l I� ::-t r�"4 ``� ' PERMIT -' PPLICATION CITY OF $.r ,... e.. Federal Way FEB 0 9 2017 [)m L A.Y F PERMIT NUMBER ( _ SITE ADDRESS I I 71'ANNIN TARGET DATE SUITE/UNIT # 5 ` ( Z C. S. r„� • 3 i rrt► 5!r -FEv 1- wAY WA. G 3 6 23 PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL # $ IF, UvO,ba TYPE OF PERMIT NAME OF PROJECT PROJECT DESCRIPTION Detailed description of work to be included on this permit only PROPERTY OWNER CONTRACTOR APPLICANT PROJECT CONTACT (The individual to receive and respond to all correspondence concerning this application) PROJECT FINANCING When value is $5,000 or more (RCW 19.27.095) 3 2 1 0- _0-- 0 0 2 q BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION WALLAt_F- `D Gf_ (< R1; 1StAtLt71 lutn 051AJ4 AL1Q.1 i'►/111' A 1�5 L rtC e- Fae. La L�_ G — AJv Th I l-V beq?,QfA}T NAME PRIMARY PHONE FeAPJ W ALL ot C Z: y25 • 830. 251767 MAILING ADDRESS E-MAIL CITY STATE I ZIP NAME I PHONE MAILING ADDRESS I E-MAIL CITY I STATE I ZIP FAX WA STATE CONTRACTOR'S LICENSE # NAME MAILING ADDRESS Iz5oo SE ZaZkc" L- CITY STATE ZIP 1Ce�oT I IJA 4 NAME 5A,P"E: 45 A?Pt-1 G,4I-�T MAILING ADDRESS CITY NAME MAILING ADDRESS, CITY, STATE, ZIP EXPIRATION DATE I FEDERAL WAY BUSINESS LICENSE # STATE I ZIP PRIMARY PHONE O E-MAU. FAX o31 PRIMARY PHONE E-MAIL FAX IR OWNER -FINANCED PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with ail applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises Out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied tothecity as apart of this application. SIGNATURE: (d��C�� r DATE 0-7-17 PRINT NAME: �G G Bulletin #100 — February 22, 2016 Page 1 of 2 k:\Handouts\Pennit Application MECHANICAL PERMIT Indicate how manjLS[eachh1Pj;offlxkirhto R installed or relocated as part of this project. Do not include existin ores to remain. AIR HANDLING,UNiTS FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS (commercial) BOILERS FURNACES HOT WATER TANKS (Gas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES PLUMBING PERMIT Indicate how many of each type 9f fixture to be installed or relocated as part of this project. Do not include existingfixtures to remain. BATHTUBS )or Tub/Shower combo) LAVS (Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS )Kitchen/Utility) WATER HEATERS (Electric) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS EXISTING/PREVIOUS USE LOT SIZE (In Squa a Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? ❑ Yes ❑ No ❑ Yes ❑ No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMENT FIRST FLOOR (or Mobile Home) SECOND FLOOR COVERED ENTRY. DECK J '7 GARAGE ❑ CARPORT ❑ OTHER (describe) EXISTING PROPOSED TOTAL Area Totals "NEW IrOMES ONLY" ESTIMATED SELLING PRICE $ # OF BEDROOMS COMMERCIAL - NEW/ADDITION AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction a # of Stories Additional Information NEW BUILDING ADDITION COMMERCIAL - REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area is Square Feet Occupancy Group(s) Construction a # of Stories Additional Information TOTAL BUILDING TENANT AREA ONLY PROJECT AREA ONLY Bulletin #100 — February 22, 2016 Page 2 of 2 k:\Handouts\Permit Application L K {J H G F E D i c i B I A I 7 I I I NOTES: LOT COVERAGE: EXISTING HOUSE 1 - 630 S.F. (HOUSE -FINISHED) EXISTING HOUSE 2 - 720 S.F. (HOUSE -UNFINISHED) EXISTING DECKS WALKWAYS 1612 S.F. (NOT AFFECTED) EXISTING GARAGE - 576 S.F. PROPOSED REVISION - 453 S.F. (DECK) TOTAL - 3,991 S. F. = 035 LOT - 1 1 6,057 S.F. PARCEL 3210200024 LEGAL DISCRIPTION: HEALY PALISADES ADD LOT 2 TGW 2ND CL TD LDS ADJ LESS BEG SW COR SD LOT 2 TH N 1-18-34 W ALG WILY LN 150 FT TH N 85-00-00 E TO E LN SD LOT 2 TH S 2-33-43 E ALG SD E LN TO SE COR SD LOT 2 TH S 85-00-00 W ALG S LN 80 FT TO POB LESS BEG SW COR SD LOT 2 TH N 1-18-34 W ALG WLY LN 165 FT TO TPOB TH CONT N 1-18-34 W 150 FT TH N 85-00-00 E 30 FT TH S 1-18-34 E 150 FT TH S 85-00-00 W 30 FT TO TPOB TGW POR LOT 1 BAAP ON E LN SD LOT 1 N 1-18-34 W 150 FT FIR SE COR THOF TH N 1-18-34 W 15 FT TH S 85-00-00 W TAP 19.7 FT N 85-00-00 E FIR W LN SD LOT TH S 15 FT TH N 85-00-00 E TO POB TGW POR LOT 1 & TD LDS LY NLY & ELY OF LN BEG SW COR SD LOT 1 TH N ALG W LN 6441.36 FT TH N 63-00-00 E 37 FT TO PT A TH S 27-00-00 E TO E LN SD LOT 1 & TPOB SD LN TH N 27-00-00 W TO PT A TH N PLC( E LN SD LOT 1 TO LN OF ORDINARY HIGH TIDE & TERMINUS SD LN TGW N 150 FT OF LOTS 3-4-5 TGW 2ND CL TD LDS ADJ SD LOTS 3-4-5 -- PER KC LLA #182081 SCOPE OF WORK: RE -CONSTRUCTION OF DAMAGED DECK OFF OF HOUSE 1, AREA 453 S.F. EXISTING AREA PROPERTY LINE LEGEND: S27'W EXISTING HOUSE 2 EXISTING WALKWAY ***NO CHANGE TO EXISTING FOOTPRINT LIKE FOR LIKE REBUILD*** EXISTING HOUSE 1 _t� �� 1�1 4�. EXISTING GARAGE CONC. PARKING AREA SITE PLAN DRAWING , : SITE PLAN 1 " = 40'-0" DATE REVISIONS BY f , s r , s f f r f t , , l' f s f , f , , f l f P f f f 4 APPROX. LOCATION OF 100 YEAR FLOOD LINE (HUD) PROJECT NAME: THE WALLACEIR-E'SIDNECE 5426 SW 315TH ST FEDERAL WAY,, WA. 98023 DESIGNER: Jeff Ruch - DRAFTER Ph# 206 919 5110 ECEI E D FEB U 9 2017 CM OF FEDERAL Vviq PERMIT SET FOR MORE INFO GO TO: v, Ww.aibdwa.org • NATIONAL 1'0UN£/OF* (CB+ID • 0 v z a z 15 N 13 i i :v i i 2 o >� mom m � � rn— C�cn� N C C) U o D rn N „D�o m w 1p 0 +o (p 5 N 3 T m L I K I J I I I H I G I F I E I D I C I B A L F E 5 2 BUILDING INFORMATION JURISDICTION: BUILDING CODE: OCCUPANCY: ZONING: CONSTRUCTION TYPE: DECKS (OFF MAIN FLOOR) TOTAL PROJECT DESCRIPTION (EXISTING) FEDERAL WAY Z R-3 SF5000 TYPE V-B RE -CONSTRUCTION OF AN EXISTING DECK (453 S.F.) WITH NO CHANGE TO THE EXISTING LOCATION. NO CHANGE TO THE EXISTING HOUSE FOOTPRINT. 453 SF 264 SF GENERAL NOTES 1. ALL WORK SHALL CONFORM TO THE IRC 2012, AND ALL OTHER STATE AND LOCAL JURISDICTION RULES AND REGULATIONS, 2. THIS SET OF WORKING DRAWINGS IS CONSIDERED A ''BUILDER SET'' AND AT THE OWNER'S REQUEST DOES NOT INCLUDE SPECIFICATIONS. IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE AND COORDINATE SPECIFICATIONS INCLUDING PRODUCT SELECTION AND INSTALLATION OR ASSEMBLY. THE DESIGNER ASSUMES NO LIABILITY OR RESPONSIBILITY FOR ERRORS OR CONFLICTS WHICH OCCUR THROUGH OWNER -SPECIFIED MATERIALS AND THEIR RESPECTIVE INSTALLATION. 3. VERIFY ALL DIMENSIONS, DATUMS, AND LEVELS PRIOR TO CONSTRUCTION. DIMENSIONS ARE TO FACE OF STUD OR TO FACE OF CONCRETE UNLESS NOTED OTHERWISE. 4. DO NOT SIGNIFICANTLY VARY OR MODIFY THE WORK SHOWN, EXCEPT WITH WRITTEN INSTRUCTIONS FROM THE DESIGNER. THE DESIGNER ASSUMES NO LIABILITY OR RESPONSIBILITY FOR UNAPPROVED VARIATIONS OR MODIFICATIONS. 5. REPORT ERRORS AND OMISSIONS TO THE DESIGNER IMMEDIATELY. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM HIS WORK. 7. GLAZING LOCATIONS SUBJECT TO HUMAN IMPACT SUCH AS PANES IN DOORS, GLAZING WITHIN 24'' OF A DOOR OPENING, GLAZING WITHIN 18'' OF A FINISHED FLOOR (ONLY IF GREATER THAN 9 SQUARE FEET), OR SHOWER DOOR AND TUB ENCLOSURES SHALL BE WIRE REINFORCED, TEMPERED OR LAMINATED SAFETY GLASS OR SHATTER RESISTANT PLASTIC PER IRC R308, 8. ALL EXPOSED EXTERIOR METAL SHALL BE GALVANIZED STEEL UNLESS NOTED OTHERWISE. ALL WOOD IN CONTACT W% CONCRETE OR MASONRY SHALL BE PRESSURE TREATED 9. REPETITIVE FEATURES ARE OFTEN DRAWN (OR NOTED) ONLY ONCE AND SHALL BE COMPLETELY PROVIDED AS IF DRAWN (OR NOTED) IN FULL. 10, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING THAT THE INTEGRITY OF THE LIFE SAFETY AND OTHER CODE REQUIRED ASSEMBLIES SUCH AS BUT NOT LIMITED TO FIRE, STRUCTURAL AND SOUND ASSEMBLIES ARE MAINTAINED BY ALL THE SUBCONTRACTORS INSTALLATIONS OF WORK. 11. THESE DRAWINGS AND DESIGN ARE THE EXCLUSIVE PROPERTY OF THE CUSTOMER. 12. PROVIDE SHOP DRAWINGS FOR THE FOLLOWING W/ REVIEWED STAMP AND SIGNATURE OF PROJECT STRUCTURAL ENGINEER FOR THE FOLLOWING : ROOF TRUSSES BIDDER -DESIGN NOTES THIS SET OF DRAWINGS DOES NOT INCLUDE ELECTRICAL, MECHANICAL, PLUMBING, AND OTHER MISCELLANEOUS DESIGNS. THE DESIGN, DRAWINGS, AND SPECIFICATIONS FOR THESE DISCIPLINES WILL BE BIDDER - PROVIDED, AND SHALL MEET ALL APPLICABLE CODES AND STANDARDS. THE DESIGNER ASSUMES NO LIABILITY OR RESPONSIBILITY FOR ERRORS OR CONFLICTS WHICH OCCUR THROUGH BIDDER -DESIGNER SPECIFIED MATERIALS AND THEIR RESPECTIVE INSTALLATION. RESIDENTIAL LOT COVERAGE LOT AREA TOTAL = 116,057 S.F. SF MAXIMUM ALLOWED = 35% PROPOSED: 453 S.F. = 3.5% (INCLUDES ALL STRUCTURES (NO CHANGE TO LOT COVERAGE) SETBACKS (SEE SITE PLAN A-0) DRAWING INDEX ARCHITECTURAL 'A' - BUILDING PLANS A-0 SITE PLAN A-1 ARCH NOTES A-2 FOOTINGS & FRAMING A-3 DECKING LAYOUT A-4 RAILING LAYOUT STRUCTURAL 'S' S-0 GENERAL NOTES S-1 DETAILS LEGAL ICI CMPTI N: GENERAL CONSTRUCTION MOTES (THE FALLOWING APPLY UNLESS SHOWN OTHERWISE ON THE DRAWINGS) CRITERIA: ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE IBC 2012 CONTRACTOR/BUILDER SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUME BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE DRAWINGS, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. EXISTING REINFORCING SHALL BE SAVED WHERE AND AS NOTED ON THE DRAWINGS. SAW CUTTING, IF AND WHERE USED, SHALL NOT CUT EXISTING REINFORCING WHICH IS TO BE SAVED. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATE BUT ARE SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. ABBREVIATIONS ARCH ARCHITECTURAL BLKG BLOCKING B, BOT BOTTOM CONIC CONCRETE CONT. CONTINUOUS DP DEEP DWG DRAWING (E) EXISTING ELEV ELEVATION EMBED EMBEDMENT EQ. EQUAL FIN FINISH FTG FOOTING MIN MINIMUM REQ REQUIRED S.O.G. SLAB ON GRADE SQ. SQUARE T.O.W. TOP OF WALL T TOP TYP TYPICAL U.O.N. UNLESS OTHERWISE NOTED "RECEIVED FEB 0 9 2017 CITY OF FEDERAL WAY CDS h I CS w r� 00 0 L w CK w Q ARCH NOTES DRAWING 0 0 L K J H 0 F C 0 PENAIT SET 0 6'— 5j 11 4 ' 1) SIZES & SPANS BASED OFF OF INFORMATION FROM DESIGN GUIDELINES FROM www.mybuidingpermit.com. I ll�l 4 6— 1 ��'-`�'j2-1***UKE FOR LIKE REBULD NOHANCE TO FOOTPMNT*** F- C-0^1 112- 6'— 4 4 Lo F\ -1 A-5 L-tj Q0 9,—gl 10' 4 MY 39'-10" Ln N- ;z 00 6 -91 4 RECEIVED o f FEB 1 092017 4 4 CITY OF FEDERAL WAY CDs Nil V) LLJ ry Li FRAMING PLAN DRAWING #: A 2 I PERMIT SET 6'— 0' �DS 4 5'-999 4' do �1 31 � d, w ,! 2 c� o , � 4 O S\GN�R O • W Y� rt � w ►� a �I� Q 0 M Q.) N EMSTNG HOUSE o0 W H � H � W M O N d' w � W z W ti W o x a SIN SIN 0 9 RECEIVE® DECKING PLAN 9'— 699 99 6') J 599 4 FEB 09 2017 DRAWING #: CITY OF FEDERAL WAY GD 39 4 PERMIT SET m all cn z 0 v� w w 0 Nlr)TF-C- i� I , METAL RAILING OR SIMILAR SUBJECT TO A 200 LBS. CONCENTRATED LOAD IN ANY DIRECTION. 2. METAL RAILING OR SIMILAR NOT TO HAVE — ANY OPENING THAT EXCEEDS 4" ***LIKE FOR LIKE REBUILD — NO CHANCE TO FOOTPRINT*** 4'— 2 1 o 41 4 4 2" FEB 092017 CITY OF COS RAL WAY <: a r w W z 0 w c� wl RAILING PLAN DRAWING z- d PERMIT SET