23-102008w
City of Federal Way
Community Development Dept.
33325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
Project Name: SOUTH CAMPUS ESTATES LOT 7
Project Address: 427 SW 366TH ST
Building - Single Family
Permit #:23-102008-00-SF
Inspection Request Line: (253) 835-3050
Parcel Number: 787965 0070
Project Description: BLUEBEAM - Construction of a 3267 square foot 2-story single family residence with a 46
square foot covered entry, a 240 square foot patio and an attached 732 square foot garage.
Includes plumbing and mechanical.
Owner
Applicant
Contractor
Lender
SOUTH CAMPUS DEVELOPMENT
GIOVANNI VENDETTIJK
J K MONARCH LLC
OWNER IS LENDER
MONARCH LLC
PO BOX 188
PO BOX 188
PO BOX 188
PUYALLUP WA 98371
PUYAL ,"UP•.WA 98371
PUYALLUP WA 98371
Census Category: 101 - New Single Family House
Includes:
# 1
#2
#3
#4
Occupancy Class:
R-3
Construction Type: e:
Tye V - B
Occupancy Load:
Floor Area (sq. ft.)
3,267.00
Additional Permit Information
New / Additional Sq. Feet - 1 st Floor .....................
1619
New / Additional Sq. Feet - 2nd Floor....................
1649
New / Additional Sq. Feet - 3rd Floor .....................
0
Occupancy # 1 - Area (Sq. Feet)...................:..........
3267
New / Additional Sq. Feet - Basement ....................
0
•t
Basic Plan?.........
No
Occupancy # 1 -Construction Type.., . .....................
Type V - B
New / Additional Sq. Feet - Deck...........................
0
New / Additional Sq. Feet - Garage ........................
732
Mechanical to be Included? .....................................
Yes
Plumbing Work Valuation? .....................................
20000
Mechanical Work Valuation?..................................
15000
Number of Stories ........................... ,.......... ,........ —
2
New / Additional Sq. Feet - Other..........................
286
Plumbing to be Included? ........................................
Yes
New / Additional Sq. Feet - Total............:.........;....
4285
Will Certificate of Occupancy be Issued? ...............
Yes
Occupancy #1 - Use................................................
Residence (1 or 2
family)
Comprehensive Plan Designation ..........................
SF - Medium Density
Zoning Designation......»..»...
g b ........._.....................
RS 15.0
Residential
Total Valuation: 584,349.40
Mechanical Fixtures
Air Handling Units 1 Air Conditioners - Stand Alont 1 Ducting 1
Fans 6 Fireplace Inserts 1 Furnaces 1
Gas Piping 1 Gas Pipe Outlets 3
Plumbing Fixtures
Bathtubs 2 Dishwashers 1 Laundry Washer Outlets l
Lavatories 5 Showers 2 Sinks 2
Water Closets 3 Water Heaters 1 Hose Bibbs 3
CONDITIONS:
FIRE APPROVAL CONDITIONS:
1. Installation of an automatic fire sprinkler system is NOT REQUIRED.
2. Demolition and construction shall conform # enuirei4nts of International Fire Code (IFC)
Chapter 33.
3. An approved carbon monoxide alarm must be installed outside of the each separate sleeping area, in
the immediate vicinity of the bedroom(s) within homes with fuel -fired appliances and/or attached
,garages. (IFC 908.7 as amended by the State of Washington)
PUBLIC WORKS DEPARTMENT APPROVAL CONDITIONS:
All work must be per plans designed Grant Middleton, PE on 11-21-2022.
PERMIT EXPIRES Wednesday, 27 December, 2023
Permit Issued on Friday, June 30, 2023
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
i t an City of Federal Way.
Owner or agent: F Date:
City of Federal Way
Certificate of occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance, this structure was in
compliance with the various ordinances of the City regulating building construction or use. This certificate is valid
ONLY when endorsed by Citystaff.
taff.
Tenant Name: SOUTH CAMPUS ESTATES LOT 7
Address: 427 SW 366TH ST
Includes: #1 #2 #3
Occupancy Class: R-T
Construction Type: Type V - B
Occupancy Load:
Floor Area (sq. ft.) 3,267.00
Owner Name: SOUTH CAMPUS DEVELOPMENT LI
Owner Address: PO BOX 188
PUYALLUP WA 98371
Building Official
Permit # 23-102008-00-SF
#4
1 3 e 7,0-zA-
Date
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees
nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or re#ulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises.
THIS CARD IS TO REMAIN ON -SITE
CITY OF Construction Inspection Record
Federal Way INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 23 102008 00 Address: 427 SW 366TH ST
Project: SOUTH CAMPUS DEVELOPMENT I FEDERAL WAY WA 98023
Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card.
SWM Precon Site Mtg (4400)
El
Site Assessment (Erosion) (4365)
0
Footings/Setback (4110)
Approved
11
To be done PRIOR to breaking ground
Approved to place concrete
By
Date
By
Date
By
A fJ Date 4 Z
:4 Foundation Wall (4115)
Approved to place concrete
By ^)( ) Date 7/q
0 Drainage/Downspout (4040)
Approved to backfill
By Date TW 4
0 Plumbing Groundwork (4190)
Approved to cover
By rJ Date g �10
7❑ Slab/Concrete Floor (4255)
0 Underfloor Framing (4285)
® Floor Sheathing (4105)
Approved to place concrete
Approved to sheath floor
Approved to install flooring
By Date
By Ad Date �;0 La
By %i Date %6
90 Shear Walls (4245)
Approved to install siding
By �' Date )aAl'o
Roof Sheathing (4220)
Approved to install roofing
By L 6 Date
12 Rough Plumbing (4230)
Approved
By L 6 Datek1o, A-3
El Mechanical Rough -in (4165)
Gas Piping (4125)
5 Fire/Draft Stops (4095)
Approved
Approved to release test
Approved
By L Date f p
By Z13 Date j� �3
l`S
By �� Date 3 J o
Interim Erosion Control (4370)EandFire/Dra
scheduling a Framing inspection; t 7 Framing (4120)
Approved , Plumbing & Mechanical Rough -in Approved to insulate
ft Stop inspections must be signedBy Date f and approved. IBC 109.3.4 By Date
113 Insulation (4150)
19 Gypsum Wallboard Nailing (4130)
20 Final Erosion Control (4375)
Approved to install wallboard
Approved to install mud & tape
Approved
By �� Date I B 2 Z
By VJ&) Date ��� �� ��
By Date
Final - Mechanical (4065)
Approved
By Date
27 Final - Plumbing (4075)
Approved
By �/� Date 1 l 34z+_
Q Final - Building (4050)
Approved
By Date C 3
Rough Electrical
Final Electrical
Right of Way
Approved
Approved
Approved
By
Date
By
Date
L By
Date
CITY OF Building Division
33325 Eighth Avenue South
Federal Way
Fetl3Way, -6325
Phone 253-835-5-25Q7 Faxx 253-8353-835-26Q9
CORRECTION NOTICE
ADDRESS: ` 7--* 5yy bT- PERMIT#: Z3 - i oZoo 8 -oo
IF YOU HAVE QUESTIONS CALL ___ L`-
(253) 835- _�� 1
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
DATE INSPECTOR
DO NOT REMOVE THIS NOTICE
Page of
FELTEW"_._.4
ARCHITECTURE I ENGINEERING I FORENSICS
July 24, 2023
JK Monarch
Re: South Campus Estates
Lot 7 3267-4T
Trimmers at Rear Sliding Glass Door
This letter is written to address the concern regarding the missing trimmers at the
rear sliding glass door. The plans call for (3) 2x6 trimmers at each side of the
opening, and it was built with (2) 2x6 trimmers at each side.
The repair shall be completed as follows.
-Attach Existing GLB header to existing 2x6 king stud w/ (2) LTP5's at each side.
-Add additional 2x6 King stud at each side.
-Nail new 2x6 king stud to existing 2x6 king stud w/ (2) 0.131" X3" nails at 12" O.C.
No other changes are required.
Please let me know if you have any questions.
Sincerely,
WAS
10/25/23
54005
FELTEN GROUP, INC.
Jacob Morgan, P.E.
Regional Vice President
JEM:jem
ARIZONA: 18325 N ALLIED WAY SUITE 200 • PHOENIX, AZ 85054 • PHONE: 602.867.2500 • FAX: 602.867.2503
COLORADO: 9025 E MINERAL, CIRCLE SUITE 200 • CENTENNIAL, Co 80112 - PHONE: 720.638.6355
WASHINGTON:23175 224T" PL SE SUrFE C, MAPLE VALLEY, WA 98032 PHONE 602.867.2500
OF
CITY
Way
Building Division
33325 Eighth Avenue South
Federal Way. WA 98'003-6325-
Phone 253-835-2607 Fax 253-83512609
CORRECTION NOTICE
ADDRESS: G PERMIT#: 23 ' lb Zooall
J _(_
ff
Aj r y
�] � ' n
j) h
` V t
h m r)Q —� j /1 S ma
IF YOU YOU HAVE QUESTIONS CALL (253) 835- 2-63 1—
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
DATE INSPECTOR ~~
DO NOT REMOVE THIS NOTICE
Page of _ _ _ _
CITY OF Building Division
33325 Eighth AveCiue South
'''''►►... WayFederal Woy. 98-63r5
Federal Phone 253-835-2bp7 Faxx 2S3.8353�-2b09
CORRECTION NOTICE
ADDRE,S& 4197 Sk✓ 366_�x 5 l PERMIT#: _'�Z3 --10").d o p
IF YOU HAVE QUESTIONS CALL ___ � � _ (253) 835-�
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
DATE INSPECTOR
DO NOT REMOVE THIS NOTICE
Page of.-
_