Loading...
23-102008w City of Federal Way Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: SOUTH CAMPUS ESTATES LOT 7 Project Address: 427 SW 366TH ST Building - Single Family Permit #:23-102008-00-SF Inspection Request Line: (253) 835-3050 Parcel Number: 787965 0070 Project Description: BLUEBEAM - Construction of a 3267 square foot 2-story single family residence with a 46 square foot covered entry, a 240 square foot patio and an attached 732 square foot garage. Includes plumbing and mechanical. Owner Applicant Contractor Lender SOUTH CAMPUS DEVELOPMENT GIOVANNI VENDETTIJK J K MONARCH LLC OWNER IS LENDER MONARCH LLC PO BOX 188 PO BOX 188 PO BOX 188 PUYALLUP WA 98371 PUYAL ,"UP•.WA 98371 PUYALLUP WA 98371 Census Category: 101 - New Single Family House Includes: # 1 #2 #3 #4 Occupancy Class: R-3 Construction Type: e: Tye V - B Occupancy Load: Floor Area (sq. ft.) 3,267.00 Additional Permit Information New / Additional Sq. Feet - 1 st Floor ..................... 1619 New / Additional Sq. Feet - 2nd Floor.................... 1649 New / Additional Sq. Feet - 3rd Floor ..................... 0 Occupancy # 1 - Area (Sq. Feet)...................:.......... 3267 New / Additional Sq. Feet - Basement .................... 0 •t Basic Plan?......... No Occupancy # 1 -Construction Type.., . ..................... Type V - B New / Additional Sq. Feet - Deck........................... 0 New / Additional Sq. Feet - Garage ........................ 732 Mechanical to be Included? ..................................... Yes Plumbing Work Valuation? ..................................... 20000 Mechanical Work Valuation?.................................. 15000 Number of Stories ........................... ,.......... ,........ — 2 New / Additional Sq. Feet - Other.......................... 286 Plumbing to be Included? ........................................ Yes New / Additional Sq. Feet - Total............:.........;.... 4285 Will Certificate of Occupancy be Issued? ............... Yes Occupancy #1 - Use................................................ Residence (1 or 2 family) Comprehensive Plan Designation .......................... SF - Medium Density Zoning Designation......»..»... g b ........._..................... RS 15.0 Residential Total Valuation: 584,349.40 Mechanical Fixtures Air Handling Units 1 Air Conditioners - Stand Alont 1 Ducting 1 Fans 6 Fireplace Inserts 1 Furnaces 1 Gas Piping 1 Gas Pipe Outlets 3 Plumbing Fixtures Bathtubs 2 Dishwashers 1 Laundry Washer Outlets l Lavatories 5 Showers 2 Sinks 2 Water Closets 3 Water Heaters 1 Hose Bibbs 3 CONDITIONS: FIRE APPROVAL CONDITIONS: 1. Installation of an automatic fire sprinkler system is NOT REQUIRED. 2. Demolition and construction shall conform # enuirei4nts of International Fire Code (IFC) Chapter 33. 3. An approved carbon monoxide alarm must be installed outside of the each separate sleeping area, in the immediate vicinity of the bedroom(s) within homes with fuel -fired appliances and/or attached ,garages. (IFC 908.7 as amended by the State of Washington) PUBLIC WORKS DEPARTMENT APPROVAL CONDITIONS: All work must be per plans designed Grant Middleton, PE on 11-21-2022. PERMIT EXPIRES Wednesday, 27 December, 2023 Permit Issued on Friday, June 30, 2023 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of i t an City of Federal Way. Owner or agent: F Date: City of Federal Way Certificate of occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by Citystaff. taff. Tenant Name: SOUTH CAMPUS ESTATES LOT 7 Address: 427 SW 366TH ST Includes: #1 #2 #3 Occupancy Class: R-T Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 3,267.00 Owner Name: SOUTH CAMPUS DEVELOPMENT LI Owner Address: PO BOX 188 PUYALLUP WA 98371 Building Official Permit # 23-102008-00-SF #4 1 3 e 7,0-zA- Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or re#ulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. THIS CARD IS TO REMAIN ON -SITE CITY OF Construction Inspection Record Federal Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 23 102008 00 Address: 427 SW 366TH ST Project: SOUTH CAMPUS DEVELOPMENT I FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. SWM Precon Site Mtg (4400) El Site Assessment (Erosion) (4365) 0 Footings/Setback (4110) Approved 11 To be done PRIOR to breaking ground Approved to place concrete By Date By Date By A fJ Date 4 Z :4 Foundation Wall (4115) Approved to place concrete By ^)( ) Date 7/q 0 Drainage/Downspout (4040) Approved to backfill By Date TW 4 0 Plumbing Groundwork (4190) Approved to cover By rJ Date g �10 7❑ Slab/Concrete Floor (4255) 0 Underfloor Framing (4285) ® Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By Ad Date �;0 La By %i Date %6 90 Shear Walls (4245) Approved to install siding By �' Date )aAl'o Roof Sheathing (4220) Approved to install roofing By L 6 Date 12 Rough Plumbing (4230) Approved By L 6 Datek1o, A-3 El Mechanical Rough -in (4165) Gas Piping (4125) 5 Fire/Draft Stops (4095) Approved Approved to release test Approved By L Date f p By Z13 Date j� �3 l`S By �� Date 3 J o Interim Erosion Control (4370)EandFire/Dra scheduling a Framing inspection; t 7 Framing (4120) Approved , Plumbing & Mechanical Rough -in Approved to insulate ft Stop inspections must be signedBy Date f and approved. IBC 109.3.4 By Date 113 Insulation (4150) 19 Gypsum Wallboard Nailing (4130) 20 Final Erosion Control (4375) Approved to install wallboard Approved to install mud & tape Approved By �� Date I B 2 Z By VJ&) Date ��� �� �� By Date Final - Mechanical (4065) Approved By Date 27 Final - Plumbing (4075) Approved By �/� Date 1 l 34z+_ Q Final - Building (4050) Approved By Date C 3 Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date L By Date CITY OF Building Division 33325 Eighth Avenue South Federal Way Fetl3Way, -6325 Phone 253-835-5-25Q7 Faxx 253-8353-835-26Q9 CORRECTION NOTICE ADDRESS: ` 7--* 5yy bT- PERMIT#: Z3 - i oZoo 8 -oo IF YOU HAVE QUESTIONS CALL ___ L`- (253) 835- _�� 1 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of FELTEW"_._.4 ARCHITECTURE I ENGINEERING I FORENSICS July 24, 2023 JK Monarch Re: South Campus Estates Lot 7 3267-4T Trimmers at Rear Sliding Glass Door This letter is written to address the concern regarding the missing trimmers at the rear sliding glass door. The plans call for (3) 2x6 trimmers at each side of the opening, and it was built with (2) 2x6 trimmers at each side. The repair shall be completed as follows. -Attach Existing GLB header to existing 2x6 king stud w/ (2) LTP5's at each side. -Add additional 2x6 King stud at each side. -Nail new 2x6 king stud to existing 2x6 king stud w/ (2) 0.131" X3" nails at 12" O.C. No other changes are required. Please let me know if you have any questions. Sincerely, WAS 10/25/23 54005 FELTEN GROUP, INC. Jacob Morgan, P.E. Regional Vice President JEM:jem ARIZONA: 18325 N ALLIED WAY SUITE 200 • PHOENIX, AZ 85054 • PHONE: 602.867.2500 • FAX: 602.867.2503 COLORADO: 9025 E MINERAL, CIRCLE SUITE 200 • CENTENNIAL, Co 80112 - PHONE: 720.638.6355 WASHINGTON:23175 224T" PL SE SUrFE C, MAPLE VALLEY, WA 98032 PHONE 602.867.2500 OF CITY Way Building Division 33325 Eighth Avenue South Federal Way. WA 98'003-6325- Phone 253-835-2607 Fax 253-83512609 CORRECTION NOTICE ADDRESS: G PERMIT#: 23 ' lb Zooall­ J _(_ ff Aj r y �] � ' n j) h ` V t h m r)Q —� j /1 S ma IF YOU YOU HAVE QUESTIONS CALL (253) 835- 2-63 1— WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR ~~ DO NOT REMOVE THIS NOTICE Page of _ _ _ _ CITY OF Building Division 33325 Eighth AveCiue South '''''►►... WayFederal Woy. 98-63r5 Federal Phone 253-835-2bp7 Faxx 2S3.8353�-2b09 CORRECTION NOTICE ADDRE,S& 4197 Sk✓ 366_�x 5 l PERMIT#: _'�Z3 --10").d o p IF YOU HAVE QUESTIONS CALL ___ � � _ (253) 835-� WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of.- _