22-101378 (2)RESUBMITTED J Ujo 0
1 plans shall be printed in color 0
separate electrical permit required LU = 0)ZD
6/6/2022 ��Of
0 Cn
MOUNTAIN SUN APARTMENTS REMODEL ��
CITY OF FEDERAL WAY Q cn� o
I` —1COMMUNITY DEVELOPMENT �w 0
1747 S 305TH PLACE FEDERAL WAY WA 98003 Ujco
7 U- 2
'1pp1" ''• ,'•
S 300th St
�
3
a
�`a`
3
" = Wfldwood
a L"-- S 301st St Park -
a
Federal Way
m
s3otstst
to
a
a
s n ^�
5 301St Ln
5 302nd St S 301st PI
S-'O
.�"
S�
S 302nd St
N
S 302ntly
5 302ntl PI
v
2;
S 303rtl St
a'
r7 a
S 302ndQ
y T
-
" "
Sao
o
' s
aSt
"
ry 5
22n6 Ct S
s 304th st S 304th St
—
S 304th St
PROJECT SITE
ltn st
MLW
S�
a
LOCATION MAP
"
a
Steel Lake
Steel
Steel Lake
5 30dth Ln
S 309th St
a"
Q0
0
SHEET INDEX — PERMIT SET
SHEET NO.
SHEET CONTENTS
ARCHITECTURAL
A001
PROJECT INFO AND INDEX
A002
ABBREVIATIONS, SYMBOLS AND LEGENDS
A003
RESIDENTIAL CODE GENERAL INFO
A004
RESIDENTIAL CODE GENERAL INFO
A005
ENERGY CODE SUMMARY INFORMATION
A006
ENERGY CODE COMPLIANCE & EQUIPMENT CUTSHEETS
A007
APPLIANCES CUTSHEETS
SITE PLAN
A101
AD101
FIRST LEVEL EXISTING & DEMO PLAN
AD102
SECOND LEVEL EXISTING & DEMO PLAN
FIRST LEVEL OVERALL FLOOR PLAN
A201
A202
SECOND LEVEL OVERALL FLOOR PLAN
A203
OVERALL ROOF PLAN
WALLS, DOORS & WINDOW SCHEDULES
A204
A205
STAIR, DECK PLAN & BUILDING ASSEMBLY NOTES
A301
BUILDING ELEVATIONS
A302
A401
BUILDING ELEVATIONS
BUILDING SECTIONS
BUI LDI NG SECTIONS
A402
A501
WINDOW INSTALLATION DETAILS
A502
TYPI CAL SI DI NG DETAI LS
TYPICAL DETAILS
A503
A504
TYPICAL STAI R DETAILS
A510
TYPICAL PROTECTION DETAILS
A701
FIRST LEVEL CEI LING PLAN
A702
SECOND LEVEL CEI LING PLAN
GENERAL NOTES
1. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE.
2. DRAWINGS HAVE BEEN PREPARED ON AN ORIGINAL SHEET SIZE OF 24" x 36".
3. HORIZONTAL DIMENSIONS SHOWN INDICATE FACE OF (F.O.) CONCRETE, F.O. STUD,
CENTERLINE OF COLUMN GRIDLINE, UNLESS OTHERWISE NOTED. VERTICAL
DIMENSIONS INDICATE TOP OF (T.O.) SLAB, T.O. SUBFLOOR, UNLESS OTHERWISE
NOTED.
4. INFORMATION REGARDING EXISTING CONDITIONS USED TO PREPARE THESE
DRAWINGS HAS BEEN PROVIDED BY OTHERS. CONTRACTOR TO FIELD VERIFY
EXISTING CONDITIONS PRIOR TO COMMENCING CONSTRUCTION. PROVIDE WRITTEN
NOTIFICATION TO THE OWNER, ENGINEER AND GENERAL CONTRACTOR OF ANY
DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE DRAWINGS. THE
OWNER WILL ISSUE A WRITTEN DIRECTIVE IF FURTHER CLARIFICATION IS REQUIRED.
5. ALL EXISTING DIMENSIONS ARE +/- AND SHALL BE VERIFIED IN FIELD PRIOR TO
INSTALLATION, FABRICATION AND CONSTRUCTION.
6. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS, DATUM, LEVELS AND
CONDITIONS PERTAINING TO THE WORK PRIOR TO COMMENCING CONSTRUCTION.
PROVIDE WRITTEN NOTIFICATION TO THE OWNER OF ANY DISCREPANCIES WITH THE
DOCUMENTS. THE OWNER WILL ISSUE A WRITTEN DIRECTIVE IF FURTHER
CLARIFICATION IS REQUIRED.
7. THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF THE OWNER AND HAVE BEEN
PREPARED FOR USE IN THE EXECUTION OF THE ENCLOSED PROJECT. USE OR
REPRODUCTION FOR ANY OTHER PURPOSE WITHOUT THE WRITTEN PERMISSION OF
OWNER IS PROHIBITED.
PROJECT NARRATIVE
REMODEL & REPAIR OF AN EXISTING FIRE DAMAGED 7-UNIT
APARTMENT BUILDING.
PROJECT INCLUDES REPLACEMENT OF ROOF TRUSSES WITH
NEW PITCHED TRUSSES AND NEW ROOFING THROUGHOUT.
EXISTING FRAMED WALL LAYOUT TO REMAIN THE SAME.
SITE WORKS INCLUDED RESTRIPING OF PARKING STALLS,
REPLACE FENCING WITH NEW BOARDS AND REPLANTING
EXISTING LANDSCAPED AREAS.
PROJECT ADDRESS
1747 S 305TH PLACE
FEDERAL WAY, WA 98003
COUNTY: KING
PARCEL INFORMATION
255817-0050
LEGAL DESCRIPTION
FIRETREE ESTATES
PLOT LOT:5
N W-9-21-4
PROJECT TEAM
APPLICANT / OWNER
YUMO CONSTRUCTION LLC
27327 48TH AVE S
KENT, WA 98032
PHONE: 253.332.2177
EMAIL: YURIYM@USA.COM
CONTACT: YURIY MOMOTYUK
PERMIT INFORMATION
JURISDICTION: CITY OF FEDERAL WAY
ARCHITECT
STEWART CHUNG AIA (WA LIC 6232)
18406 101st ST. E
BONNEY LAKE, WA 98391
PHONE: 253.227.9710
EMAIL: ROCKYCFLORES@GMAIL.COM
CONTACT: ROCKY FLORES
• 2018 WASHINGTON STATE EXISTING BUILDING CODE (WSEBC)
• 2018 WASHINGTON STATE BUILDING CODE (WSBC)
• 2018 WASHINGTON STATE FIRE CODE
• 2018 WASHINGTON STATE MECHANICAL CODE
• 2018 WA STATE ENERGY CODE (WSEC) RESIDENTIAL PROVISIONS
CODE AS AMENDED AND ADOPTED BY THE STATE BUILDING CODE COUNCIL
AND THE CITY OF FEDERAL WAY
ZONING CLASSIFICATION:
RM1800
OCCUPANCY GROUPS:
R2
TYPE OF CONTRUCTION:
TYPE VB
FIRE SPRINKLERS: 1
NON SPRINKLERED (NS)
SEPARATE/ DEFERRED PERMIT
(AS REQUIRED BY CITY OR STATE, AUTHORITY HAVING JURISDICTION):
PLUMBING PERMIT
ELECTRICAL PERMIT
0
W
U
a
J
am
6232
REGISTERED
ARCHITECT
STEWART CH
STATE OF WASHI GTON
THIS DOCUMENT HAS BEEN PREPARED
FOR PERMIT APPLICATION AND IS
SUBJECT TO REVIEW AND MODIFICATION
BY GOVERNMENTAL AGENCIES
DATE ISSUE
\0. DATE REVISION
1 6.1.2022 COMMENT RESPONSE 1
PROJECT N0.
22021
BLDG DEPT PROJECT NO.
CHECK PROJECT TEAM MEMBERS
PERMIT SET 6.1.2022
PROJECT INFO
AND INDEX
A001
RESI DENTIAL UNIT AREA CALCS
APPROX. AREA
(SQUARE FEET)
FIRST LEVEL
COMMON AREA
UNIT A
382 SF
804 SF
UNIT B
1,023 SF
UNIT C
798 SF
3,007 SF
SECOND LEVEL
COMMON AREA
292 SF
UNIT D
804 SF
UNIT E
559 SF
UNIT F
554 SF
UNIT G
798 SF
3,007 SF
OVERALL GFA AREA 6,013 SF
EXISTING PRIOR TO FIRE DAMAGE
SOUTH (FRONT) VIEWPOINT
SOUTH WEST VIEWPOINT
GROSS FLOOR AREA
APPROX. AREA
(SQUARE FEET)
FIRST LEVEL 3,007 SF
SECOND LEVEL 3,007 SF
OVERALL GFA AREA 6,013 SF
SOUTH EAST VIEWPOINT
Eo
Lo
z.0
Lo
1 SUBMITTED
5' - 89 - 9' 1951
JJ / it 0 2 2
SITE PLAN
1" = 10'-0"
CITY 'qF�„ FEDERAL WAY
CO DEVELOPMENT
_PROPERTY LINE
o
XISTING CONCRETE PAD
RATIO TO REMAIN,
TYPICAL
OUTDOOR HEAT PUMP
PAD, TYPICAL
LINE OF NEW 6'-0" HIGH
WOOD FENCE WITH GATE
EXISTING PARKING
STALLS TO BE RESTRIPED
SETBACK LINE, TYPICAL
EXISTING TREES, TYPICAL
0 2.5' 5' 10' 20'
ui 00
�co
O
Z
0
L
Q
ZD
o-
O
e
�Q
�w
0
W
ui
u
o
■
Q
W
J
am
Lo
C)
m
U)
III
R1
Isft
6232
REGISTERED
ARCHITECT
STEWART CH
STATE OF WASHI GTON
THIS DOCUMENT HAS BEEN PREPARED
FOR PERMIT APPLICATION AND IS
SUBJECT TO REVIEW AND MODIFICATION
BY GOVERNMENTAL AGENCIES
DATE ISSUE
NO. DATE REVISION
PROJECT NO.
22021
BLDG DEPTPROJECT NO.
CHECK PROJECT TEAM MEMBERS
PERMIT SET 6.1.2022
SITE PLAN
A101