18-1013234CITY OF
s,. Federal Way
Centered on Opportunilly
June 8, 2018
Austin Groves
R J Development
401 Central Street SE
Olympia, WA 98501
austin@rjdevelopment.com
1FILE
33325 8th Avenue South
Federal Way, WA 98003-6325
(253) 835-7000
www.cityoffederalway.com
Jim Ferrell, Mayor
RE: File #18-101323-00-AD; SITE PLAN MODIFICATION APPROVAL
Village Green Memory Care, *NO SITE ADDRESS*, Federal Way
Dear Mr. Groves:
The City's Department of Community Development is in receipt of your request to modify the approved
Village Green Phase III (Cottages West) site plan. The project was first granted Process IV approval on
April 23, 2002, with subsequent Process IV approval for a 10-year extension granted June 1,_2010 (File
#'s 00-104145-UP & 08-105555-UP). The project is valid until June 2, 2020. According to the March 23,
2018, submitted modification request and May 15, 2018, May 17, 2018, May 21, 2018, and May 23,
2018, resubmittals, minor modifications to the site plan include removing two cottage units and replacing
them with a Memory Care facility and community building. Associate site work and landscape
modifications are proposed.
The request for site plan modification is hereby approved. Pursuant to Federal Way Revised Code (FWRC)
19.15.090(3), the modification request is consistent with city codes as found in the enclosed Exhibit A -
Findings for Approval and incorporated into this decision by reference.
There are no changes to site access points or impacts to the environment with the requested site plan
modifications. The proposed building modification is consistent with the approved June 1, 2010 Process
IV decision, does not create additional impacts, and complies with Federal Way Revised Code (FWRC)
requirements.
The original Process IV approval decision and the site plans approved and referenced in the June 1, 2010,
Process IV approval are still valid and applicable, with the minor modification approved herein.
This modification approval does not waive compliance with future City of Federal Way codes, policies,
and standards relating to this development. If you have any questions regarding this decision, please
contact Associate Planner Becky Chapin at 253-835-2641, or becky.chapin@cityoffederalway.com.
Sincerely,
Brian Davis
Community Development Director
Mr. Groves
June 8, 2018
Page 2
enc: Findings of Approval
Interpretation of Recent Proposal for Memory Care Facility, June 30, 2017
Approved Modification Site Plan
Brooks Powell, brooks@powell-homes.com
Hal Duncanson, haroldd@duncansonco.com
Kevin Peterson, Engineering Plans Reviewer
Sarady Long, Sr. Transportation Planning Engineer
18-101323-00-AD Doc. LD. 77754
CITY OF
Federal Way
)n oppollbluF,
Findings for Project Approval
Village Green Memory Care, File #18-101323-00-AD
Federal Way Revised Code (FWRC) Chapter 19.15.090(3)
The Director of Community Development hereby makes the following findings pursuant to the site plan
modification process as set forth in Federal Way Revised Code (FWRC) 19.15.090(3).
Proposal — The modification proposal involves the addition of a Memory Care facility and community
building in the Cottage West portion of the Village Green Campus. The Cottage West (Phase III project)
was previously granted a Process IV approval on June 1, 2010. According to the March 23, 2018,
submitted modification request and May 15, 2018, resubmittal, minor modifications to the site include
removing two cottage units and replacing them with a Memory Care facility and community building.
Revised landscaping and internal roads are included. No additional units are being proposed.
2. Comprehensive Plan & Zoning — Zoning for the subject site is Single Family Residential (RS9.6).
Senior citizen or special needs housing uses are permitted in the RS 9.6 zone under Federal Way City
Code (FWCC) Section 22-640 and FWRC 19.200.100.1 Village Green Phase III (Cottages West) is
vested to the FWCC that was in effect on December 15, 2008, which is the date of the complete
application, and further is only subject to the applicable portions of the FWRC that are consistent with
the December 15, 2008, FWCC.
The Federal Way Comprehensive Plan (FWCP) designation for the subject site is Single Family High
Density.
3. Site Plan Review Process — Per Memorandum prepared by Planning Manager Robert "Doc" Hansen,
dated June 30, 2017, it was concluded that the proposal for the creation of a memory care facility meets
the intent of, and is in substantial conformance with, the decisions made under Process IV for Village
Green, and does not require a Process IV public hearing (memo enclosed).
The current proposal is for a Modification to the Approved Site Plan, which is processed through an
Administrative Decision (AD) request. The Director of Community Development makes a written
decision on the application based on criteria listed under FWRC 19.15.090(3).
4. State Environmental Policy Act (SEPA) — Under SEPA, an Environmental Determination of
Nonsignificance (DNS) was issued for the approved Process IV project on March 13, 2010. This
determination was based on review of information in the project file, including the environmental
checklist and the "Final Staff Evaluation for Environmental Checklist," resulting in the conclusion that
the proposal would not result in probable significant adverse impacts on the environment. No new
1 On October 9, 2009, the City Council reorganized the Federal Way City Code (FWCC) into the Federal Way Revised Code
(FWRC). On May 24, 2017, FWRC 19.200.100 was amended.
impacts are anticipated with the modification request, and therefore, is not subject to any further SEPA
review.
5. Public Notice & Comment — Site Plan Modification Approval is an Administrative Decision and no
public notification is required.
Required Yards — Per Section 22-640 (FWRC 19.200.100), the project has a 20-foot front yard
setback and 5-foot side and rear yard setbacks. The proposed Memory Care facility and community
building meet all required setbacks.
Facade Length Modification — Residents occupying the building will be senior citizens who have
Alzheimer's or other forms of dementia. The building is a purpose-built Memory Care building that
will be licensed through the Washington State Department of Health. The building's size is required
to incorporate the State required safety elements for the building. The Memory Care building will
include dining facilities, laundry service, nurse's stations, common activity spaces, and outdoor
spaces. The fagade lengths are unable to adhere to the 120 feet max length and include the spaces
inside the building required to obtain an Assisted Living/Memory Care license in the State of
Washington. The building massing is broken up with modulations, landscape screening, and
balconies. The facades are consistent with the overall design of the Village Green Campus.
8. Building Height — The maximum height for buildings is 30 feet above average elevation. Building
height is measured to the mid -point between eave and ridge of the highest principal roof of a sloped
roof. The proposed elevations depict the mid -point of the roof of the Memory Care building to be 29
feet, below the building maximum height. The community building, at one story, does not exceed the
30-foot maximum height.
9. Parking — A revised parking study prepared by Jake Traffic Engineering, Inc. (JTE) was submitted
on May 23, 2018. The report concludes that 0.88 parking stalls per unit will be provided for the entire
Village Green Retirement Campus, or 323 parking stalls. The proposal includes a parking garage
under the building with 28 parking stalls, four (4) surface stalls near the main entrance, and six (6)
stalls near the community building entrance. The remaining stalls are located throughout the Village
Green site. Ample parking is provided on site to accommodate occasional parking by friends and
family and staff.
10. Landscaping — Minor modifications to the approved landscape plan are also proposed to
accommodate the Memory Care facility. There are two required balconies that protrude into the 20-
foot Type II perimeter landscaping. Due to topography, height limitations, and site constraints the
south side of the building is the only area feasible to meet State requirements for balconies/outdoor
space. Landscaping along the south property line would be 9 feet for the portion of the building with
the balcony. The remaining landscape buffer has been increased to 27 feet of Type II landscaping.
11. Crime Prevention Through Environmental Design (CPTED) — The applicant submitted a CPTED
checklist as a component of the AD request for the Memory Care and community buildings. Staff
finds the applicant has met the intent of CPTED and provides measures that include, but are not
limited to: natural surveillance; site and building layout; landscaping; lighting; access control; and
entrance visibility.
12. Community Design Guidelines — The proposed buildings incorporate building forms, materials, and
treatment methods consistent with the guidelines, including structural modulation; varied roof
heights; strong architectural emphasis at building entrances; variety of material and colors; foundation
Findings for Project Approval — Village Green Memory Care Page 2 of 3
File 13-101323-00-AD Doc. LD. 77755
41
1
landscaping; and pedestrian amenities. Site and architectural design is consistent with FWRC Chapter
19.115, "Community Design Guidelines," based on provision of key design elements identified as
follows:
The proposed buildings are designed to emphasize the natural topography. Landscaping is
incorporated around the foundation of the buildings to eliminate the building massing. The parking is
located at grade and will be fully enclosed under the building. There are sidewalks and walking paths
throughout the site. Outdoor furniture will be placed at the front of the Memory Care and community
buildings to provide residents with outdoor living space.
The buildings utilize materials and significant structural modulation to minimize the facade lengths.
Exterior materials include varied sidings, visible window trim, and glazing. The roof heights and
slopes will be varied and add architectural design and character to the building. Both buildings are
oriented towards the right-of-way to provide visual access into human services and activities within
the building. Overall, the building design is consistent with the design used for the existing buildings
on the Village Green Campus.
13. The application and attachments have been determined to be consistent with the FWCP; all applicable
provisions of the FWRC; and with the public health, safety, and welfare. The proposed development is
consistent with decisional criteria listed under FWRC 19.15.090(3). This decision shall not waive
compliance with future City of Federal Way codes, policies, and standards relating to this development.
Prepared by: Becky Chapin, Associate Planner Date: June 5, 2018
Findings for Project Approval — Village Green Memory Care
File 18-101323-00-AD
Page 3 of 3
Doc. I.D. 77755
121"go"EMMMSE !mmm
==Mae
,7.
;Fall
km
MAX
Iq 4,40-
� IT
7 M�7
66
ho
jlft�
Pt,
miff -
v L
'�'�.•f r
ir;,:.
'E'
- ��.II •� Sri
-'`I• �••.
��, 1••`Y
__�•
;` `�'+yyr _ .. } - -
�jj
- M
.Ri
10
• - •��x="ti` r`-,�- -'lsxn . is -'�3�' .
.�' — y �-. l' - • `�J' of ';i , •r; .. Y �r�r-L.�j' . � wu.
�•- •�. }. ter, •.ram, � . y�
'Emm'
i
I�
II .-
�� �fit. < <. w—r . e' ; ' � ��=�'c • } h - - f f . ' .. '�
°I + 'R Sri 1 Imo' . }' v! "{`r.�'•. • _ �' /s' li J
_. � - 'may '. •� i - -
ppp-
mm
_b66
A V
0
mm
616.4 k
51.
4
.�y7
ML
kv
� � mA.
JWE
WL
.t
11
i C
k
qF
llprpl
T -4 OW
ftN
I'm M-1
a
4;L
� i3f PG
j DEVELOPMENT PMENi
SEPI10175 INC �LIVERI
Becky Chapin
City of Federal Way
Planning Department
33325 81h Avenue South
Federal Way, WA 98003
Re: File # 18-101323-00 AD; TECHNICAL REVIEW COMMENT LETTER
Village Green Memory Care, *No Site Address, Parcel #302104-9146, Federal Way
Federal Way Community Design Guidelines
Village Green Memory Care and Community Building Narrative for the City of Federal Way
Process IV Administrative Decision
The narrative is to demonstrate how the proposed Memory Care building and Community building on the current
Village Green retirement campus will comply with the current Community Design Guidelines found in FWCC
19.115 and CPTED guidelines.
Memory Care Buildin
The proposed Memory Care building has three floors to the building. The top two floors contain resident rooms,
nursing stations as well as indoor and outdoor common area space for resident use as required by the Washington
State Department of Health. The bottom floor of the building utilizes the natural topography of the site and
houses the underbuilding parking, and service areas of the building including commercial kitchen, laundry,
elevators and mechanical rooms. The top two floors will be seen from the entrance and upper roadway, which
scales the building to other surrounding uses and allows it to not look out of place or as an afterthought.
The design of the Memory Care building is cohesive with the surrounding uses and uses similar design elements
already existing on the exterior of other Village Green Retirement Campus buildings. The intent in design of The
Memory Care building is to further create the "Campus feel" for the Village Green Retirement Campus that
compliments existing buildings which will protect property values of the surrounding buildings and homes and
enhances the general appearance of the area.
Community Building
The Community Building is being designed as a gathering place for the residents of the Independent Living
Cottages on the campus. The Community Building will have tables, chairs, a fireplace and a catering kitchen where
meals can brought in. This space is designed for card playing, movie watching and gathering to create more of a
community feel for the residents of the community. Although there are parking spaces that will be provided with
the building, any guests will be encouraged to park at the resident's cottage and walk to the community building
RJ Development
401 Central St SE —Olympia, WA 98501
(360) 528-3343 — www.r'develo ment.com
to minimize the need for parking. The Community Building will be replacing 3 previously approved cottages, which
will reduce the overall impact of traffic and use on the campus.
The desijzn
CPTED principles are being implemented in the following manner for the Memory Care building:
o Natural Surveillance:
o The Memory Care building is situated on the site in an area that has good visibility from multiple
points on the campus and will be accessed by a gated entry to the South along 2"d Ave. SW and
from another access road from 357th Place which is internal to the campus and passes by other
buildings and residents. The front of the building will have a well lit resident dropoff area and
security features near the front door. The road down to the under building parking will be well lit
and have a garage door that will be shut at night and is visible from multiple cottages onsite.
o To access the Community Building, one must drive past either the fully staffed Memory Care
Building or the fully staffed Independent Living/Assisted Living building on the site and is a safe
location campus wide from a security perspective.
• Access Control:
o The Memory Care building will have a fully staffed receptionist and the ability to lock the doors to
the exterior as well as the parking area. The building is designed to keep people indoors and safe
as will not have unlocked doors (unless it is the "outdoor resident space" or front door that will
be monitored by staff. The South side of the building will be fenced off and screened by Type II
landscaping to prevent people from accessing the South side of the building.
o The Community Building will have locking doors and will be kept locked unless staff unlocks the
doors and allows residents to access the buildings.
Ownership:
o The Memory Care Building will be staffed and lived in 24 hours per day with lights on and activity,
which will eliminate the sense that the building is "ownerless".
o The Community Building will be used on a regular basis and will have lights on when not in use to
make sure that it is not seen as "ownerless". To access the Community Building, one must drive
past either the fully staffed Memory Care Building or the fully staffed Independent Living/Assisted
Living building on the site and is a safe location campus wide from a security perspective.
Security Program:
Policies and procedures including evacuation plans, emergency and security plans are implemented will be
implemented in the proposed Memory Care building, which is required for State licensing. These policies are in
place in other buildings on campus. A weekly safety meeting onsite is help to review policies and procedures.
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343)—www.rodevela rnerit.corn
The building is custom built to make sure that the residents are safe inside and is the driving force behind the
design and the need to have the design such that a variance is needed for the fagade length of the building. Nurses
stations are centrally located to the building to keep site lines open so that staff will have eyes on the residents at
all times to ensure the safety and comfort of the residents. The main laundry room is only accessible to staff. The
"resident laundry" room is for families to do a quick load of laundry if needed while they are visiting the residents
and is located in the corridors and is visible for staff. Proper illumination in all areas (entry, lobby, corridors,
common areas, resident rooms, garage, etc.) of the building will be adhered to for all areas that residents and
staff, guests and service personnel will have access to and will be monitored by staff and state auditors during
licensing inspections.
Landscaping is a large part of the campus and full time landscapers are employed to ensure that the landscape is
trimmed up to provide visibility and will discourage people from hiding.
Site Design — FWCC 19.115.050
1 (a). The Memory Care building and Community Building have been designed in a way to work with the natural
topography. Significant trees will be kept onsite and natural landscape will be installed to keep the site looking as
natural as possible.
1(g). There are sidewalks and walking paths and residents are encouraged to walk around the campus on a regular
basis. The presence of the residents and staff cuts down on crime in the area.
3 (a). Landscape screening will be incorporated on the West side of the Memory Care building near the garage
entrance and will eliminate the massing of the first floor. The parking at grade under the building will be fully
enclosed under the building.
4 (c). Cross walks are incorporated into the sidewalk plan to encourage walking around the campus instead of
driving to the community building and for exercise.
4 (e). Outdfoor furniture will be located at the front entry of the Memory Care building and Community Building
as well s the outdoor balconies that will provide the residents outdoor living space.
Building Design - FWCC 19.115.060
1 (a). The proposed Memory Care Building and Community Building emphasize the natural topography and the
infrastructure that is installed to utilize the campus as designed and previously approved through Process IV.
2 (a). The buildings utilize materials and bump outs to minimize the fagade lengths and achieve the overall length
and size to provide the State required physical plant items needed to obtain licensure in the building. The facades
adhere to the minimum depth and width for modulations.
2 (b). Landscape buffers are being used on the South side of the building as well as the West side of the building
where facade lengths are greater than 60 feet. The facade lengths are required to be greater than 60` due to the
nature of the building with residents living inside of the building that cannot have unrestricted access to the
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343) — www.rodevetopnient.com
exterior of the building due to elopement risk. Common areas and corridors are required for exercise as the
unrestricted access to the out of doors is not allowed from a State licensing perspective.
Artist's Representation of the Southern fagade:
Artist's Representation of the Western fagade:
Building and pedestrian orientation—119.115.070
The Memory Care Building and the Community Building are both oriented toward the right of way and both
provide visual access into human services and activities within the buildings.
Both the addition of the Memory Care Building and the Community Building have been thoughtfully planned for
the Village Green Retirement Campus to take care of the senior residents and those in need in Federal Way. The
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343) — www.rmdevelo ment.com
buildings have been designed to compliment the community of Federal Way and make the Village Green
Retirement Campus feel like home for those who live within the buildings
Please let me know if you need anything further at this time.
Thank you,
Austin Groves
Project Manager
RJ Development
401 Central St SE • Olympia, WA 98501
Office • (360) 528-3343
Direct • (360) 810-8354
Fax • (360) 534-9079
Email • austin@ridevelopment.com
Web • www.ridevelopment.com
"Seniors Housing Delivered"'"
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343) — www,ridevelopment.com
FROM LAND USE
APPROVAL
INTERNATIONAL BUILDING CODE, 2006 ED. W/
WA STATE ADMENDMENTS. WA STATE
ENERGY, 2006 ED. WA STATE VENTILATION &
INDOOR AIR QUALITY CODES, 2006 ED-
REQUESTED
REVISION
NUMBER OF UNITS
PHASE I - EXISTING:
IBC 2015 EDITION & WAC51-11C WA BUILDING A.
26
STATE ENERGY CODE 2012 BUILDING B: 32
BUILDING C: 20
SUB -TOTAL: 94
CONSTRUCTION TYPE: MEMORY CARE: V—A
PHASE
TYPE V-B 1 HOUR
GEXISTING:
BUILDING D:
30
OCCUPANCY TYPE:
BUILDING E
29
LC, LICENSED CARE REQUIRES STATE OF WA 11, CONDITION 2, S2
SUB -TOTAL:
59
BOARDING HOME LICENSE
PHASE II:
FIRE PROTECTION:
BUILDING F:
50
SPRINKLERED THROUGHOUT PER NFPA 13-R
BUILDING G:
32
BUILDING H:
25
BUILDING 1:
32
SITE
BUILDING J:
35
ZONING:
SUBTOTAL:
174
PHASE I & II: RS 7.2
PHASE III: RS 9.6
PHASE III:
SUS -TOTAL:
40
NE 1/4 SEC 30, TWP 21 N, ROE 4 E, W.M.
VILLAGE GREEN OF FEDERAL WAY
SIZE, TOTAL:
APPROX. 22 ACRES
TOTAL NUMBER OF UNITS: 367
PHASE I & 11-EXISTING:
377,467.0 S.F.
PHASE 11:
187.780.0 S.F.
FLOOR AREA CALLS
PHASE
393 l 7.0 S-F.
PHASE I -EXISTING (BLDGS A.B,C
TOTAL:
958,404.0 S.F.
BASEMENT: 15,060.0 S.F.
LOT COVERAGE:
1ST FLOOR: 30,639.0 S F,
2ND FLOOR: 28,992.0 S.F.
PHASE I & II -EXISTING:
73,193.0 S.F.
3RD FLOOR: 1 796-0 S.F.
LOT COVERAGE (BLDGS):
19,4%<60%
SUB -TO AL: 98,487-0 S-F.
PHASE II: 58,157.0 S-F-
PHASE I -EXISTING (8 COTTAGES):
LOT COVERAGE (BLDGS): 31.1%<60%
SUB -TOTAL: 24,432.0 S.F.
S.F.
75, 234 SF
PHASE H-EXISTING (BLDGS D,E):
17.5%,60%
19.1%, <60% MAX ALLOWEDBASEMENT:
L8,300.OS.F,
1ST FLOOR: 21,780.0 S.F.
=68,786.08,786.0
00,136.0 S.F,
206,584
2ND FLOOR: 18,484.0 S.F.
20.8%<60%
21-6%, <60% MAX ALLOWED
gRDFLOOR: 14.154.0S.F.
SUB -TOTAL: 72,718.0 S,F.
PHASE lT (BLDGS F,G.H,I,J):
BULK REGULATIONS
1ST FLOOR: 55,B08.0 S.F.
SETBACKS:
2ND FLOOR: 55.479.0 S.F.
FRONT: 20 FEET
3RD FLOOR: 43-379-0 S.F.
SIDE: 5 FEET
SUB -TOTAL: 154,666-0 S-F-
REAR: 5 FEET
FROM SF ZONE: 100 FEET
PHASE III (COTTAGE CLUSTERS I-XIII):
SUB -TOTAL: 103,242.0 S.F.
BLI)G - FELT ABOVL• - ' A-1.3
TOTAL FLOOR AREA: 443,545.0 S.F.
BLDG HEIGHT WITHIN 100 FEET OF SINGLE
FAMILY ZONE: 15 FEET PLUS 5 FEET TO AVERAGE
ROOF HEIGHT OF 20 FEET.
NOTE: SEE SITEPLAN, BLDG J AND ELEV. A/2 DOES
NOT EXCEED 20 FEET IN HEIGHT.
MAX BLDG WIDTH WITHIN 100 FEET OF SINGLE
FAMILY ZONE: 50 FEET
MOD RE(�UIRED FOR FA OVER 50
FEET
MIN. DEPTH: 3 FEET
MIN. WIDTH: 4 FEET
MAX. WIDTH 35 FEET
NOTE: ALL FACADES ARE MODULATED PER
ABOVE.
MAX, LENGTH OF BUILDING FACADES: 120 FEET
NOTE: REQUESTING MODIFICATION FOR ALL
BUILDING FACADES OVER 120'-D' IN LENGTH.
BUILDING F: 32
BUILDING G: 27
BUILDING H: 25
BUILDING I: 32
RIIILDING J: 30
SUBTOTAL: 146
COTTAGES: 28
MEMORY CARE:40
SUB —TOTAL: 68
TOTAL NUMBER OF UNITS: 367
PARKING
PHASE I & II (MULTI -FAMILY):
NUMBER OF UNITS:
315
NUMBER OF EXISTWG PARKING STALLS:
103
NUMBER OF NEW STALLS:
120
SUB -TOTAL OF PARKING:
223
PARKING RATIO (UNTTS/TOTAL STALLS)
1.4 OR
( 71 STALLS PER UNIT)
PHASE I (SINGLE-FAMILY):
NUMBER OF UNITS:
16
NUMBER OF EXISTING PARKING STALLS:
16
NUMBER OF NEW STALLS:
0
SUB -TOTAL OF PARKING:
16
PARKING RATIO (UNITS/TOTAL STjO.6
OR
(I STALLS PER UNIT)
NUMBER OF SINGLE FAMILY UNITS:
28
PHASE III (SINGLE-FAMILY):NUMBER
MEMORY AR NIT •
4
NUMBER OF UNITS:
SUB— TOTAL OF UNITS:
68
NUMBER OF EXISTING PARKING S
NITMHER F NEW STALLS:PROPOSED
TOTAL NUMBER OF STALLS:
42 (COTTAGES)
SUB -TOTAL OF PARKING:PROPOSED
TOTAL NUMBER OF STALLS:
30 (MEMORY CARE)
PARKING RATIO (UNITS/TOTAL STR
T PAR I
I
(1-5 STALLS PER UNIT)SUB—TOTAL
OF PARKING:
84
PARKING RATIO (UNITS/STALL
0.8 OR
TOTAL PARKING FOR ENTIRE SITE:
TOTAL NUMBER OF UNITS 367
TOTAL NUMBER OF PARKING STALLS 312
PARKING RATIO (UNITS/TOTAL STALLS) 1-2 OR
($3 STALLS PER UNIT)
INFORMATION BASED ON NOV. 5, 2008 STUDY BY TSI
(TRANSPORTATION SOLUTIONS INC., REDMOND. WA) FOR
DISCUSSION ON PARKING DEMAND.
SEE SHEET A-1.1 FOR ADDITIONAL PARKING INFORMATION
(1.2 STALLS PER UNIT)
TOTAL NUMBER OF UNITS: 367
TOTAL NUMBER OF PARKING STALLS: 323
PARKING RATIO (UNITS/TOTAL STALLS): 1,14 OR
(0.88 STALLS PER UNIT)
PHASE III
COTTAGE CLUSTERS I —IV, VI —XI:
85,895 SF
MEMORY CARE BASEMENT:
17,192 SF
MEMORY CARE 1ST FLOOR:
18,035 SF
MEMORY CARE 2ND FLOOR:
17,958 SF
COMMUNITY BUILDING:
5,760 SF
PHASE III SUB —TOTAL:
144.840 SF RESUBMITTED
MAY 21 2018
Crnr OF FEDERAL WAY
CC MMUNMY DEVELDpf.{- j,�
Know what's below.
Call 48 hours before you dig.
DUNCANSON
Company, Inc.
145 SW 155rh Srreer, Suite 102
Se tk, W hingron 98166
Phone 206244L4141
F- 206244.4455
tl
z
00
c
Q
w3
9
C3 a
0 W
m Z
Q W
CL M
J_
>
W
o
_ Z
W O
> c0
tL
W co z
(n z Q
Q � tL
IL a L_
lA
DRAWN:
HMD
DCI NO:
98480.5
DATE:
3/20/18
� Y
ne.t
AD2
2 OF
2 SHEETS
X:\PROJECTS\1998 PROJECTS\98480 VG MEM\98480 VG C3D\VILLAGE GREEN -SHEET C1 DWG
December 2611, 2017
Mr. Austin Groves
RJ Development
401 Central Street SE
Olympia, WA 98501
Dear Mr. Groves:
RESUBMITTED
MAY 17 2018
CfTY OF FEDERAL WAY
C* MMUNFFY DEVELOPMENT
41ir
AMERICAN FOREST
MANAGEMENT
RE: Village Green Tree Assessment December 2017
We have completed a thorough tree assessment of the tree retention area of the new
Village Green development site. A map indicating the project area is attached. The tree
retention area is a portion of parcel #3021049146, located within the City of Federal Way.
It is our understanding that a new community building, and new homes will be built near this
tree retention area. Additionally, new trails will be constructed directly adjacent to the tree
retention area. An inventory and condition/risk assessment of all significant trees within the
tree retention area was conducted.
In order to maintain risks at acceptable levels, the removal of five of the subject trees is
recommended.
A Tree Summary Table can be found at the back of this report which describes the 159
trees that were assessed. A Tree Map is also attached which identifies the approximate
location of trees recommended for removal and shows the limits of the tree retention area.
All subject trees have been identified with a numbered aluminum tag. Trees that are
recommended for removal have a tree tag and a piece of pink flagging.
Description
All trees with DBH's (trunk diameter measured at 4.5' above ground) equal to or greater
than 6" were included in the assessment.
The subject study area is predominantly a second -growth even -aged forest dominated by
Douglas fir. In addition to Douglas fir, there is also a minor component of native hardwood
species such as Pacific madrone and black cottonwood. The area has a slight slope.
Subject areas are dry and are not prone to flooding or saturated soil conditions. The
understory is dominated by salal, a native shrub.
The subject trees were assessed in December 2017.
Tree Risk Assessment
The assignment was to inventory and assess all significant trees of six inches DBH or larger
in the subject area. The trees were assessed under TRAQ (Tree Risk Assessor Qualified)
Level 2 Basic Assessment methods (visual inspection). This assessment is valid for the
conditions of the tree and site on the date of inspection and does consider the future site
improvements.
11415 NE 128th St., Suite 110, Kirkland, WA 98034 I Phone: 425.820.3420 1 Fax: 425.820.3437
americonforestmanagement.com
December 26rh, 2017
Page 2
TRAQ Level 2 Assessment
Village Green — Tree Assessment
• Locate and Identify Subject Trees
• Determine Targets
• Review Site History
• Assess Tree Health
• Inspect: ocular, mallet, probes etc.
• Record Observations: defects, site conditions, growth rates
• Determine the Likelihood and consequences of failure
• Determine Level of Risk
• Recommend Mitigation if appropriate
• Suggest re -inspection levels
Assessment tools used included a probe, laser rangefinder, mallet, hatchet, hand lens
(magnifier), relaskop to measure tree height, and diameter tape. Multiple photographs
were taken to aid in the description of tree conditions. These can be found at the end of
this report.
A risk rating is provided on the summary tables for each subject tree. A qualitative rating
is assigned based on likelihood of failure, likelihood of impact, and consequences of a
failure. The main targets for subject trees assumed in this assessment include the
existing homes, the existing road, the proposed new buildings and the proposed new
trail.
Findings and Discussion
In total, 159 trees were assessed. The majority of the subject area is densely forested and
dominated by Douglas fir. In most areas, trees are under heavy competition for sunlight,
moisture and space. Common tree defects are described below. For information on specific
trees, see the attached summary tree tables.
Trees growing closely together often develop poor trunk taper and low live crown ratios. The
change in diameter over length is called taper. Taper is an important indicator of
mechanical strength of a trees crown. Tall, skinny trees are considered to have poor taper.
Trees with poor taper are subject to stem failure when placed under heavy stress loads,
such as unusually heavy winds, ice and snow events. Live crown ratio is the ratio of the
length of the live crown to the total height of the tree, expressed as a percent. Trees
growing in a forested environment are protected from the elements and do not need to
develop large anchoring root systems. As long as the trees are retained as groupings and
not isolated, failure risk remains low. Based on the proposed plan, few trees will be isolated
or exposed to southwest prevailing winds.
Tree Retention
In total, there are 154 viable trees in the tree retention area. The entire property is 4.86
acres.
In order to maintain risks at acceptable levels, the removal of five trees is recommended.
Risks can be abated by dropping or habitat snagging the subject trees to a safe height or
distance from the nearest target. Trees can be topped in a manner to resemble a natural
break, therefore removing the risk while maintaining valuable wildlife habitat.
AMERICAN FOREST MANAGEMENT, INC.
December 26', 2017
Page 3
/)
Village Green — Tree Assessment
The tree units were calculated from the City of Federal Way code Table 19.120.130-2 —
Tree Unit Credits. The total tree units in the tree retention area is 301. Village Green is
zoned, single family high density. For single family homes, the required tree unit density
is 25 tree units/acre. The site is 4.86 acres so 121.5 tree units are required in total. 301
tree units will be retained in the tree retention area so this requirement will easily be met.
There is no warranty suggested for any of the trees subject to this report. Weather, latent tree
conditions, and future man -caused activities could cause physiologic changes and deteriorating tree
condition. Over time, deteriorating tree conditions may appear and there may be conditions, which
are not now visible which, could cause tree failure. This report or the verbal comments made at the
site in no way warrant the structural stability or long term condition of any tree, but represent my
opinion based on the observations made.
Nearly all trees in any condition standing within reach of improvements or human use areas represent
hazards that could lead to damage or injury.
Please call if you have any questions or concerns.
Sincerely,
Kelly Wilkinson
kelly.wilkinson@afmforest.com
ISA Certified Arborist #PN-7673A
ISA Tree Risk Assessment Qualified
Enclosures:
Tree Locator Map — Trees Recommended for Removal
Tree Summary Table
AMERICAN FOREST MANAGEMENT, INC.
OWN -
I., WIN a
Li 7-
t1%
eo
RMut,
'IA
A
it
� • s. 1. ..fi'." '�• •• --• � ���
17 tal P
�-41
't.��.�--47.•� �iF'�1� ��jdL:
OL • 1,+ - + •1 1 . �a py�,lYiYi
Ke
ita syrF31i+ � i ��
ve.
st, 4 pv
J
Tree Summary Table
For: Village Green
American Forest
Management,
Inc
Date:
December 2017
City of Federal Way
Inspectors:
Wilkinson
Tree/
DBH
Tree
Height
Drip -Line
Risk
Tag #
Species
(inches)
Units
(feet)
(feet)
Condition
Rating
Comment
1
Douglas fir
12
1.5
75
8
good
low
2
Douglas fir
19
2.5
115
11
good
low
3
Douglas fir
13
2
95
9
fair
low
Forked top
4
Douglas fir
17
2
121
7
good
low
5
Douglas fir
15
2
118
10
good
low
6
Douglas fir
9
1.5
59
4
fair
low
Forked top
7
Douglas fir
26
3
126
12
good
low
8
Douglas fir
11
1.5
90
5
good
low
9
Douglas fir
19
2.5
136
9
good
low
10
Douglas fir
14
2
108
7
good
low
11
Douglas fir
17
2.5
126
7
good
low
12
Douglas fir
7
1
57
6
fair
low
Suppressed
13
Pacific madrone
10
47
poor
moderate
Dead stems, 10% LCR, 108' from house
14
Douglas fir
21
2.5
117
12
good
low
15
Douglas fir
14
2
120
7
good
low
Poor taper
16
Douglas fir
20
2.5
121
13
good
low
17
Douglas fir
23
2.5
125
12
good
low
18
Douglas fir
22
2.5
130
9
good
low
19
Pacific madrone
9
1.5
44
7
fair
low
Some dieback
20
Douglas fir
19
2.5
123
10
good
low
21
Douglas fir
9
65
4
poor
moderate
Suppressed, 10% LCR, 110' from home
22
Douglas fir
18
2
110
5
good
low
23
Douglas fir
15
2
95
7
good
low
Asymmetrical crown
24
Douglas fir
8
1.5
53
5
good
low
Top broke off
25
Douglas fir
14
2
120
10
good
I low
26
Douglas fir
9
1.5
85
13
good
low
27
Douglas fir
19
2.5
130
10
good
low
28
Douglas fir
8
1.5
85
5
fair
low
Suppressed
29
Douglas fir
18
2
125
13
good
low
30
Douglas fir
21
2.5
122
15
good
low
31
Douglas fir
19
2.5
130
12
32
Douglas fir
20
2.5
135
13
�goodlow
low
33
Douglas fir
17
2
120
9
good
low
34
Douglas fir
14
2
102
8
fair
low
Forks halfway up
35
Douglas fir
10
1.5
53
6
fair
low
Top broke off
36
Douglas fir
12
1.5
104
4
fair
low
37
Douglas fir
9
1.5
65
9
fair
low
Suppressed
38
Douglas fir
18
2
120
10
good
low
39
Douglas fir
16
2
123
9
good
low
40
Douglas fir
18
2
119
11
good
low
41
Douglas fir
24
3
145
18
good
low
42
Douglas fir
16
2
134
9
good
low
43
Douglas fir
19
2.5
140
12
good
low
44
Douglas fir
8
1.5
92
4
fair
low
Poor taper, narrow crown
45
Douglas fir
15
2
123
13
good
low
46
Douglas fir
18
2
130
8
good
low
47
Douglas fir
27
3
143
17
good
low
48
Douglas fir
15
2
87
8
fair
low
Top broke off
49
Douglas fir
10
1.5
118
5
fair
low
Poor taper, narrow crown
50
Douglas fir
15
2
125
9
good
low
51
Douglas fir
20
2.5
145
13
good
low
52
Douglas fir
18
2
147
4
fair
low
53
Douglas fir
9
1.5
72
6
fair
low
54
Douglas fir
16
2
128
9
good
low
1 of 3
Tree Summary Table
For: Village Green
American Forest
Management,
Inc
Date.
December 2017
City of Federal
Way
Inspectors:
Wilkinson
Tree/ DBH
Tree
Height
Drip -Line
Risk
Tag # Species (inches)
Units
;feet)
(feet)
Condition
Rating
Comment
55 Douglas fir 21
2.5
130
10
good
low
56 Douglas fir 24
2.5
135
13
good
low
57 Douglas fir 19
2.5
143
8
good
low
58 Douglas fir 7
1.5
46
5
fair
low
59 Douglas fir 20
2.5
134
11
good
low
Spike knot on lower trunk
60 Douglas fir 22
2.5
140
13
good
low
61 Douglas fir 20
2.5
118
9
good
low
62 Douglas fir 7
1.5
72
5
fair
low
Thin crown
63 Douglas fir 29
3
134
10
good
low
64 Douglas fir 13
2
101
7
fair
low
65 Douglas fir 11
86
10
poor
moderate
Top broke off, 20% LCR
66 Douglas fir 15
81
9
poor
moderate
Top broke off, small LCR
67 Douglas fir 17
2
126
10
good
low
68 Douglas fir 11
1.5
95
4
poor
moderate
Crooked top, very small LCR
69 Douglas fir 10
1.5
74
4
fair
low
Small LCR, suppresssed
70 Douglas fir 18
2
112
9
good
low
71 Douglas fir 16
2
99
7
fair
low
72 Douglas fir 17
2
118
11
fair
low
Thin crown
73 Douglas fir 8
1.5
71
9
fair
low
Asymmetrical crown
74 Douglas fir 21
2.5
134
10
good I
low
75 Douglas fir 10
1.5
70
9
fair
low
76 Douglas fir 16
2
120
13
fair
low
77 Pacific madrone 9
1.5
65
2
fair
low
Very small live crown
78 Douglas fir 19
2.5
126
8
good
low
79 Douglas fir 17
2
120
11
good
low
80 Douglas fir 10
1.5
90
6
fair
low
81 Douglas fir 12
1.5
101
5
fair
low
Asymmetrical crown
82 Douglas fir 30
3
1 138
17
good
low
83 Douglas fir 24
2.5
138
12
good
low
84 Douglas fir 19
2.5
118
11
good
low
85 Douglas fir 8
1.5
5
fair
low
Narrow crown
86 Douglas fir 1 13
2
117
6
good
low
87 Douglas fir 10
1.5
86
7
fair
low
88 Douglas fir 12
1.5
89
9
fair
low
89 Douglas fir 7
1.5
90
6
fair
low
Crooked top
90 Douglas fir 21
2.5
105
19
fair
low
Crooked top, forked trunk
91 Douglas fir 16
2
130
11
good
low
92 Douglas fir 16
2
131
9
good
low
93 Douglas fir 17
2
134
12
good
low
94 Pacific madrone 12,8
2
74
11
fair
low
Small live crown, dead trunks, low risk
95 Douglas fir 9
1.5
66
5
fair
low
Top broke off
96 Douglas fir 18
2
120
9
good
low
97 Douglas fir 18
2
118
12
fair
low
98 Douglas fir 15
2
114
9
fair
low
Asymmetrical crown
99 Douglas fir 6
1
70
8
fair
low
100 Douglas fir 12
1.5
113
5
fair
low
Poor taper, trunk bows
101 Douglas fir 10
1.5
108
5
fair
low
Top broke off
102 Douglas fir 13
2
90
7
good
low
103 Douglas fir 9
1.5
75
5
fair
low
Thin crown. Suppressed
104 Douglas fir 11
1.5
76
3
fair
low
Narrow crown
105 Douglas fir 9
1.5
80
4
fair
low
Poor taper
106 Douglas fir 10
1.5
83
4
fair
low
Poor taper
107 Douglas fir 19
2.5
108
11
fair
low
Asymmetrical crown
108 Douglas fir 10
1.5
63
9
fair
low
Suppressed
2of3
Tree Summary Table
For: Village Green
City of Federal Way
Tree/ DBH Tree
Tan ±E nariPC finrhPs1 Units
American Forest Management, Inc
Date: December 2017
Inspectors: Wilkinson
Height Drip -Line Risk
(feet) (feet) Condition Rating Comment
109
Douglas fir
11
1.5
100
6
fair
low
110
Douglas fir
14
2
125
8
good
low
111
Douglas fir
16
2
126
10
good
low
112
Douglas fir
20
2.5
132
13
good
low
113
Douglas fir
15
2
130
8
good
low
114
Douglas fir
11
1.5
90
4
fair
low
Thin crown
115
Douglas fir
15
2
88
9
fair
low
Forked top
116
Douglas fir
8
40
7
poor
moderate
Top broke off, 10% LCR
117
Douglas fir
7
1.5
65
3
fair
low
118
Douglas fir
9
1.5
71
9
fair
low
119
Douglas fir
7
1.5
70
4
fair
low
120
Douglas fir
10
1.5
69
12
fair
L low
Forked top
121
Douglas fir
10
1.5
73
7
fair
low
122
Douglas fir
14
2
108
9
good
low
123
Douglas fir
9
1.5
79
6
fair
low
124
Douglas fir
16
2
114
9
good
low
125
Douglas fir
11
1.5
86
4
fair
low
126
Douglas fir
18
2
99
6
fair
low
127
Douglas fir
10
1.5
88
5
fair
low
128
Douglas fir
7
1.5
75
3
fair
low
129
Douglas fir
23
2.5
130
10
good
low
130
Douglas fir
23
2.5
141
14
good
low
131
Douglas fir
19
2.5
120
7
good
low
132
Douglas fir
18
2
116
13
good
low
133
Douglas fir
23
2.5
123
14
good
low
134
Douglas fir
20
2.5 1
147
12
good
low
135
Douglas fir
25
3
150
16
good
low
136
Douglas fir
12
1.5
66
17
fair
low
Top broke off
137
Douglas fir
12
1.5
78
7
fair
low
138
Douglas fir
8
1.5
55
6
fair
low
139
Douglas fir
7
1.5
50
5
fair
low
Thin crown
140
Douglas fir
17
2
99
8
good
low
141
Douglas fir
20
2.5
117
14
fair
low
142
Douglas fir
14
2
100
8
fair
low
Forked top
143
Douglas fir
12
1.5
98
6
fair
low
Thin crown
144
Douglas fir
9
1.5
62
6
fair
low
145
Douglas fir
9
1.5
65
4
fair
low
Thin crown, poor trunk taper
146
Douglas fir
16
2
130
13
good
low
147
Douglas fir
17
2
134
12
good
low
148
Douglas fir
11
1.5
98
5
fair
low
Narrow crown
149
Douglas fir
7
1.5
59
5
fair
low
150
Douglas fir
15
2
117
8
fair
low
Crooked trunk
151
Douglas fir
13
2
96
7
fair
low
Poor taper
152
Douglas fir
13
2
97
6
fair
low
Narrow crown
153
Douglas fir
25
3
127
14
good
low
154
Douglas fir
13
2
101
6
good
low
155
black cottonwood
16
2
142
8
fair
low
156
Douglas fir
18
2
110
9
good
low
157
Douglas fir
13
2
119
10
good
low
158
Douglas fir
1 16
2
130
9
good
low
159
Douglas fir
22
2.5
131
10
good
low
3 of 3
REbi 2N'6
J EVELOPMENT
HUUSING DELIVERED
Becky Chapin RESUBMITTED
City of Federal Way MAY 17 2018
Planning Department
33325 8th Avenue South CITY CF FEDERAL WAY
Federal Way, WA 98003 commuvy OiyELOPMEN7
Re: File # 18-101323-00 AD; TECHNICAL REVIEW COMMENT LETTER
Village Green Memory Care, *No Site Address, Parcel #302104-9146, Federal Way
Updated landscape Modification Request 5 1712018
Becky,
We are requesting that the Director of Community Development modify specific landscape buffer requirements
to the adjacent parcels due to the unique and special circumstances of the use of this site for the Village Green
Memory Care Building.
FWCC 22-1570 Modification options
We believe that the proposed modifications to our site comply with the stated purpose of FWCC 22-1570 as our
proposed building usage does not meet the express terms found within FWCC 22-1564 through FWCC 22-1567.
The stated purpose of FWCC 22-1570 allows the Director of Community Development the authority to modify
specific requirements applicable to our site. Our site requires a 20' landscape buffer along the South property line
in between the Village Green Memory Care site on the Village Green Retirement Campus and the site to the South
property line. The Village Green Memory Care building was designed with a 27' setback from the property line to
give more room for the required Type II landscaping on the South side of the building than required. Our initial
intent was to create walking paths and gathering areas for the residents of the building. After consulting the
Washington State codes for Assisted Living, and because the building is more than one story on height, we were
required to provide outdoor space for the residents on each living floor. This required the addition of two
balconies. When studied, the South side of the building was the only viable option due to topography and existing
infrastructure in place. The building will create housing and a homelike environment for those suffering from
Alzheimer's and other forms of Dementia. Because of the memory conditions of the residents, we are required
to provide safe, contained outdoor space where the residents cannot wander from the building and get lost. The
Department of Health requirements, required the modification of the plans and functionality of the outdoor space
for the residents. We took the required amount of outdoor space per individual (25 SF) per floor and designed
the outdoor living space to meet those requirements. The balconies were designed to encroach in the landscape
RJ Development
401 Central St SE — Olympia, WA 98501
(360)528-3343—www.rodevelo ment.com
setbacks to the least amount feasible and still meet the State Department of Health requirements, even wrapping
around the West side of the building as to not encroach into the setbacks further. The result is that the covered
outdoor living space for the residents encroaches into the 20' landscape buffer for 73'9", which is a small portion
of the South property line. An overall review of the sheet C1 of the administrative site plan review sheet shows
that this is the only area that does not comply with the 20' landscaping setback, and is the result of State licensure
requirements for this type of building and care model.
22-1570 Modification options 2 (c) (1):
The landscaping maybe reduced by 25 percent when: A development retains an additional 10 percent of
significant trees. A tree survey was conducted by American Forestry Management for this request and process.
American Forestry Management found that there were 159 significant trees, mostly Douglas Firs in the
"undisturbed wooded area" on the site West of the building. American Forestry Management found that only 5
trees are required to be removed due to safety hazards, allowing 154 trees to remain onsite. With only 3% of the
trees requiring removal for the overall Administrative Amendment, this is below the 10 percent threshold and
should qualify for the 25 percent reduction in landscape requirement that can be related to this portion of the
project. A copy of the report is included with this letter.
22-1570 Modification options 2 (d):
"The landscaping requirement may be modified when necessary, because of special circumstances relating to the
size, shape, topography, vegetation, location or surroundings of the subject property, to provide it with use rights
and privileges permitted to other property in the vicinity and zone in which it is located."
We feel that a modification is necessary and justified due to the special circumstances of the residents being cared
for inside of the building and the State requirements that we must adhere to, to be licensed to care for those with
Alzheimer's and other forms of Dementia. We request that the plans be approved as shown on the Landscape
Modification plan with the balconies encroaching into the landscape buffer for the portion of the building
necessary to achieve the outdoor space requirement. If the balconies were to be reduced, they would not be in
compliance with DSHS, as they would not meet the minimum square footage per resident requirement.
The overall dimensions of the Memory Care landscaping area on the South side of the building is 156'4". Of that
area, 82'6" has 27' of a Type II landscape buffer from the property line to the building. The requested modification
is for 73'9" of that landscape area where the Type II landscape would be 9' in depth. The balconies that protrude
from the building are 14'6", which is the minimum size allowed for resident usage and approval by Department
of Health. There is no part of this area that would not include the Type II landscaping that is required, only a
reduced amount of landscape buffer is being requested to be taken into consideration for approval.
Included with this letter is a revised sheet (AD1) provided by our Civil Engineer, Harold Duncanson. The revisions
to this sheet include an adjustment to the minimum setback along the eastern portion of the site to 9'. The
Landscape Modification Plan is being included along with the American Forestry Report for your review.
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343) —www.r develo ment.com
Monte Powell, owner of Powell'sWood Garden in Federal Way, and this project is passionate about landscaping
and will ensure that the appropriate ongoing maintenance will be in place to meet the city's requirements for the
intent of the Type II landscape screening that will be installed to ensure that it thrives and is well cared for.
This letter is an update to the previous letter submitted, that has additional justification for the Administrative
Decision and approval of the plans.
As the building is currently designed with the outdoor space balconies, the Washington State Department of
Health has approved the building for construction and has provided an Authorization to Begin Construction letter
based upon meeting the State requirements. If any additional information is needed for approval of these plans,
please let us know and we will provide any additional documentation necessary for the approval of the plans as
submitted.
Thank you,
A�p�Zw�
Austin Groves
Project Manager
RI Development
401 Central St SE • Olympia, WA 98501
Office • (360) 528-3343
Direct • (360) 810-8354
Fax • (360) 534-9079
Email • austin rldevela ment.com
Web • WWW.ridevelooment.com
"Seniors Housing Delivered" T"
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343)—www.rodevel❑ ment.com
7Ft,t 2r(6
RjVELOPMEN i HOUSING GELIVEHEU
Becky Chapin
City of Federal Way
Planning Department
33325 8th Avenue South
Federal Way, WA 98003
RESUBMITTED
MAY 15 2018
UTY OF FEDERAL WAY
COMMUNCTY DEVELOPMErlT
Re: File # 18-101323-00 AD; TECHNICAL REVIEW COMMENT LETTER
Village Green Memory Care, *No Site Address, Parcel #302104-9146, Federal Way
Becky Chapin,
Below, you will find responses for the City comment letter dated April 27, 2018 for the Village Green Process IV
Administrative Amendment to include the Memory Care and Community building on the Village Green
Retirement Campus.
City Comment: The total number of units has changed from what was approved under the Process IV
Hearing Examiner's Decision. The total number of units cannot exceed 367 units. The additional units for
the Memory Care Facility must be deducted from the Phase II building unit count. Please revise the unit
count on Sheet AD2 accordingly.
Response: The total number of units for the campus remains unchanged from the original Process IV
approvals, totaling 367 units. The site plan has been updated to reflect this number of total units.
2. City Comment: The previous parking needs and trip generation report, prepared by Transportation
Solutions Inc., dated November 5, 2008, should be revised to reflect the needs of the proposed Memory
Care Facility and community building. Further, the parking study should be revised to identify staff
parking needs and reflect PM peak hour parking needs.
Response: A trip generation report has been prepared for the Memory Care Building and the
Community Building by Mark Jacobs of Jake Traffic Engineering and is included in this letter. Overall
peak hour trips have been included for the Memory Care building. The parking count study is in process
to be completed by Mark Jacobs due to the urgent nature of the report and will be delivered to the City
of Federal Way as soon as it is completed.
RJ Development
401 Central St SE — Olympia, WA 98501
(360) 528-3343 — www.r'develggLrLent.com
TABLE 2 - TRIP GENERATION (preliminary)
VILLAGE GREEN MEMORY CARE - FEDERAL WAY
DELTA TRIP GENERATION
Time Period Size (X) I
TG Rate
I Enter o
LEnter Trips I
Exit %
lExit Tripsl
Total (T)
propose : 5 ate
Weekday
64
2.6
50%
83.2
50%
83.2
166.4
AM peak hour
64
0.19
63%
7.7
37%
4.51
12.2
PM peak hour (City)
64
0.26
38%
6.3
62%
10.31
16.6
Existing: Senior Adult Housing Attached
(1TE LUC 252; 13 - units)
Weekday
-13
3.7
50%
(24.1)
50%
-24.1
-48.1
AM peak hour
-13
0.2
35%
(0.9)
65%
-1.7
-2.6
PM peak hour (City)
-13
0.26
55°%
(1.9)
45%
-1.5
-3.4
# elta-Site Trip Generation
Weekday -
-
-
59.2
--
59.2
118.3
AM peak hour 1-
-
6.8
2.8
9.6
PM peak hour (City) -
-
4.5
-
8.8
13.3
Where X = units; T = Trips
ITE Trio Generation 10th Edition
3, City Comment: Under FWCC section 22-640 note #5, no facade of any structure may exceed 120 feet in
length; however, under note #3, the City may permit or require modification of dimensional and site
design requirements based on the following criteria:
a. The specific nature of the occupancy and the persons that will be housed in the proposed
development.
b. The size of the dwelling units or occupancy rooms or suites and the specific configuration of and
facilities within these units, rooms or suites.
c. The impacts on nearby residential uses of the proposed development.
d. The architecture, site design and other design features of the proposed development.
Provide written explanation as to how the building meets modification criteria.
a. The specific nature of the occupancy and the persons that will be housed in the proposed
development.
Response: The residents occupying the building will be Senior citizens who have Alzheimer's or other forms of
dementia. This building is a purpose-built Memory Care building that will be licensed through the Washington
State Department of Health. The building's size is required to incorporate the State Required safety elements
RJ Development
401 Central St SE - Olympia, WA 98501
(360-528-3343) - www.ridevelgp t.com
for the building. The building will include Fire suppression sprinklers and a Fire Alarm System along with smoke
compartments with smoke barrier doors that will be held open with magnetic locks which will allow residents to
shelter in place in the event of a fire. Dining facilities, Laundry service, Nurse's Stations, common activity spaces,
outdoor spaces, are all incorporated into the building to make this a living facility licensed by the State of
Washington. The dwelling units will be equipped with a bed (mattress and headboard) a nightstand and dresser
to create a warm, homelike feeling for the residents. Bathroom facilities will be included in each resident unit.
The units will not contain kitchenettes due to the nature of cognitive issues, this poses a risk for harm of the
residents.
The Southern fagade is 154'6" in length, and is the minimum length that could be utilized with the incorporation
of the dining facilities and outdoor space required by the State of Washington Department of Health. The fagade
length is unable to adhere to the 60 max length and include the spaces inside the building required to obtain an
Assisted Living/Memory Care license in the State of Washington. The building massing is broken up with building
modulations, including portions of the building protruding between 2'-4'. Type II landscape screening is included
and two balconies are provided to meet the requirement from the Washington State Department of Health for
outdoor space for the residents. From the artist rending below, the residential portion can be distinguished
from the service portion (Dining and outdoor space) and allows the fagade to look shortened and not one big
expanse.
The Western fagade length is 161' and is the minimum length that could be utilized with the incorporation of the
dining facilities and outdoor space required by the State of Washington Department of Health. The fagade
length cannot be shortened and still include the spaces inside the building required to obtain an Assisted
Living/Memory Care license in the State of Washington. The building massing is broken up with building
modulations, with portions of the elevations protruding from the building from 2'-5' in depth to provide visual
interest and shield the sidewalk below providing pedestrians shelter from the elements. From the artist rending
below, the residential portion with smaller windows can be distinguished from the service portion (Dining and
activity rooms) and allows the fagade to look shortened and not one big expanse. The site plan depicting the
fagade lengths as well as artist renderings are included below.
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343) — www.ridevelo Pment.com
LqP
CbTTanE UNIT
•/
1
1
OUTLINE O ROOF
Fprk x:oHM.11UY
n2rw uF
-
r
Fac.tua Inng'li z�ong Ilrn Vlr••.tr�n
propirtty
line is 161'v+ith Scree��J"Y+
neighboring
Parcelx by hrauy'nrreElapmt FL)n�*. glh
to ba juslihed ,^. pnaa[ nsralive
r
i
F- �.---------•---
I
PROPOSED MEMORY CARE
INITM $4 BE S
I
ri+nno'xu�ntrssnns�e
rrHoannwurars+rs�.■
�
3
I
'
n1 w I
I
I IDOORPr, IO KI> +
I
ILAMMsSILM t C�
*0=9r
I
1RAA1 NiPREC1'CILYG�
5i FCOCar 1,Cle s F
Ft Airt F—:
QF TF 1
cof.LiCr
6 :i
".a
a�
Facade length a'ora ;he Sou!• - , PROPFiTY
SNCIF FAMILY HOI- LandS�ape S LlBB ping b eth9-r
buddingyir n-i 1, -I hTylu9 SNr{=_Pot111LY
budding ;uiJ neighbunng Single
HO67E
>,
N Fa ily co,he south.
.y ay: ngN iswIO9. Mlrr
urojecl nw.cr,,,.
Artist's Representation of the Western fagade:
Artist's Representation of the Southern fagade:
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343) — www.ridevelopment.com
4. City Comment: As noted in the preapplication conference letter, the formal application must include a
written narrative identifying how the project complies with all applicable guidelines, as detailed in the
FWRC Chapter 19.115 (FWCC Chapter 22, Article XIX), 'Community Design Guidelines'
Response: A separate narrative is included with this submittal that outlines how the project complies
with applicable Community Design Guidelines and CPTED standards.
5. City Comment: The approved landscape plans depict 20 feet of Type II landscaping along the south
property line abutting the single family houses. The submitted plans do not meet this standard. Based
on the discussion at the meeting, held on Thursday, April 26, 2018, you indicated that revised
landscaping plans would meet this requirement. Please submit the revised landscape plans for review.
Pursuant to FWRC 19.125.100 (FWC 22-1570) any landscape modification requests must be submitted in
writing and reviewed as part of the AD approval.
Response: The landscape plans previously submitted did not show the Type II landscape screening to the
South of the Memory Care Building. The plans have been revised to include a 27' Type II landscape
screening buffer for the majority of the South Elevation. The areas on the South Elevation that do not
include the landscape buffer are utilized for outdoor patios that are required by the Washington State
Department of Health. The outdoor patios do not give excess space over the requirements from the State
to give as much room to the Landscaping area to meet the City of Federal Way landscape buffer
requirements. Type II landscape buffer will be depicted on the plans and updated landscape plans will be
submitted along with this resubmittal. A depiction of the Type II landscape buffer is shown below.
Updated plans and a landscape modification request will be submitted to the City of Federal Way pursuant
to FWRC 19.125.100.
Response: This building will have little to no impact on nearby residential uses to the South as the
building will be screened by dense landscape screening and is contained in the existing Village Green
Retirement Campus. As Memory Care residents don't drive, the impacts on roadways and neighboring
developments are minimal. This building will have Registered Nurse's staffed and on call 24 hours per
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343)—www.ridevelo ment.eom
day which minimizes the need to call 911 emergency services, which lessens the impact and burden on
the emergency service personnel in the area.
OUTLINE
DE•:AVDF -
1
P3L-1[HT L+f:•Jth xxg rnn'.Vn:!r'rn Pr7Pnrry .
_I:+ie S IG1''N:t•$:rPan eG !.'^r++ne•'JFG:1.:�]
R'nr k': L�'+r,t>•y foirr--'a!:c•1 ` �• s-� -r
Ip Qv !usvrad r. wc;t:r Da'•..-..,-
rf
r_ ---------- - _
;PROPOSED MEMORY CARE'
1TH 64 6E S e J
' I humgar.uulrs�x AFRA wruaruw.V�s ARF1.A
-
�
I
A1Tm I I
TRk%1ANDAECV I'll;
CALLELTN]M
E\1£N4ENCY OE`4144TGN
5
SNGLF FMILV HmTE
9UTDOON PAYI0 14
MT Fig
-AID F.C4R
� N
_
Facade lvrpT'+a.c-•�!he 5r.�,r. Pnpw_4T1'I
n t7TG' -) Type II gNAc
LandEcapa Screening W*-er.
orDPnny and
'-.��iIINg, and nvghpgnD9 Singly
I-ecade LCng1n :n WD j%r.rr 111
Prajed nAna'r.c
µ.OSC"LDANCA�
N:LDFS'18[E b
f\^
tM1F.
q\\IILV H(]M1TE
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343)—www.r•develo ment.com
27'{
6. City Comment: Provide a description of the community building and who will be utilizing the building.
Response: The Community building is for the benefit of the Independent Living Cottage Residents. The
community building is intended to be a gathering place to play cards, watch TV and movies and have the
occasional meal catered in for the benefit of the residents. Any guests that would come would be
encouraged to park in the resident's driveways and walk to the community building. The kitchen is
intended to be a serving kitchen, and not a full commercial kitchen. The kitchen and any accompanying
equipment will be permitted through the proper jurisdiction.
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343) — www.r"develop ment.com
Community Building Elevations shown below:
Community Building Floor Plan shown below:
I I ii I T-] 1
�I
1 i
r r r
I —
;K
Mill
If there is anything further needed at this time, please reach out as necessary.
Thanks for all of your help!
Austin Groves
Project Manager
RJ Development
401 Central St SE • Olympia, WA 98501
Office • (360) 528-3343
Direct • (360) 810-8354
Fax •(360)534-9079
Email • austin ddevelOPment.com
Web • www.ridevel❑.pment.com
Seniors Housing Delivered"'
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343)—www.ridevelopment.com
"R -
£,,1 2Pf6
j DEVELOPMENT
S CUI UHS HUUS IIN6 0E! IVEREO
Becky Chapin
City of Federal Way
Planning Department
33325 8th Avenue South
Federal Way, WA 98003
RESUBMITTED
MAY 15 2018
CITY F WAY
GOM UNITY DEVE FEDERAL
Re; File # 18-101323-00 AD; TECHNICAL REVIEW COMMENT LETTER
Village Green Memory Care, *No Site Address, Parcel #302104-9146, Federal Way
Written Landscape Modification Re uest
We received the comment below on the Process IV Administrative Review Comments regarding the landscaped
area on the South side of the Village Green Memory Care Building:
The approved landscape plans depict 20 feet of Type II landscaping along the south property line abutting the
single family houses. The submitted plans do not meet this standard. Based on the discussion at the meeting,
held on Thursday, April 26, 2018, you indicated that revised landscaping plans would meet this requirement.
Please submit the revised landscape plans for review.
Pursuant to FWRC 19.125.100 (FWC 22-1570) any landscape modification requests must be submitted in writing
and reviewed as part of the AD approval.
The plans that were referenced in the meeting on April 26, 2018 showed several items on the South side of the
building.
1. There are two balconies that protrude off of the South side of the building. As the building is for
Memory Care residents (those with Alzheimer's and other forms of Dementia), there must be an area at
least 25 feet per person of outdoor space per Clynn Wilkenson, plan reviewer for the Washington State
Department of Health, Construction Review Services. As this building must be licensed to take care of
the needs of the residents, we must meet this State requirement. Due to the topography of the site and
height limitations for the building, the South side of the building is the only area that is feasible to meet
this State requirement and provide a quality standard of living for the residents in the building. These
balconies/outdoor space are not larger than needed to provide this required space. In designing the
building, we attempted to meet City and State codes and guidelines and as such, this is the only variance
that we are requesting at this time.
2. Although there is a 20' type II landscape buffer that is required, we were able to provide a 27'-28' buffer
in places to the East of the balconies between the building and the single family homes. We have tried
to be a flexible as possible and meet both City and State codes in this area.
RJ Development
401 Central St SE — Olympia, WA 98501
(360) 528-3343 — www.ridevelopment.com
Although we have not been able to meet the 20' buffer for the entire length of the South end of the property,
we request that the City review and approve the Landscape drawings for the Village Green Memory Care
building dated March 20, 2018 as we feel that we have met the intent of the Federal Way code and the State
Department of Health requirements.
Thank you,
(372 ncP60--
Austin Groves
Project Manager
RJ Development
401 Central St SE • Olympia, WA 98501
Office • (360) 528-3343
Direct • (360) 810-8354
Fax • (360) 534-9079
Email • austin ridevelopment.com
Web • www.ridevelopment.com
"Seniors Housing Delivered" I"
RJ Development
401 Central St SE — Olympia, WA 98501
(360-528-3343) — www,ridevelopment.com
4k
CITY Federal o,
Way
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
RESU B� A ITTE325 8`h Avenue South
�V1 PO Box 9718
Federal Way WA 98063-9718
MAY 15 22i5-2607; Fax 253-835-2609
www.ciiyoffedeTalwAy.com
CfTY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
Crime Prevention Through Environmental
Design (CPTED) Checklist
Directions
Please fill out the checklist to indicate which strategies have been used to implement CPTED principles in
your proposed project. Please check all strategies that are applicable to your project for each of the
numbered guidelines. You may check more than one strategy for each guideline.
Your responses will be evaluated by City Staff, and will be integrated into the Site Plan and/or Building
Permit review process.
Section and ✓ Functional Area Evaluation for
Performance Performance Standard Agency Use Only
Standard
Strategy
■ Applicable during Site Plan Review
e Applicable during Building Permit Review
Section 1.0 Natural Surveillance
1.1 Blind Corners _Conforms
Avoid blind corners in pathways and parking lots. _Revise
_NA
Comments:
Pathways should be direct. All barriers along pathways should
be permeable (see through) including landscaping, fencing etc.
■
Consider the installation of mirrors to allow users to see ahead
of them and around corners. e
Other strategy used:,
1.2 Site and Building Layout _Conforms
Allow natural observation from the street to the use, from the _ . Revise
use to the street, and between uses _NA
Comments:
Bulletin #022 — August 18, 2004 Page 1 of 9 k:\Handouts\CPTED Checklist
Section and ✓ Functional Area
Performance Performance Standard
Standard
Strategy
■ Applicable during Site Plan Review
e Applicable during Building Permit Review
Orient the main entrance towards the street or both streets on
For Non -Single corners. ■
Family
Development
Position habitable rooms with windows at the front of the
dwelling. ■
Access to dwellings or other uses above commercial/ retail
development should not be from the rear of the building. ■
Offset windows, doorways and balconies to allow for natural
observation while protecting privacy. ■
❑ Locate main entrances/exits at the front of the site and in view
of the street. ■
For Commercial/
Retail/ Industrial If employee entrances must be separated from the main
and Community ❑ entrance, they should maximize opportunities for natural
Facilities surveillance from the street. ■
❑ In industrial developments, administration/offices should be
located at the front of the building. M
Avoid large expanses of parking. Where large expanses of
For Surface ® parking are proposed, provide surveillance such as security
Parking and cameras. ■
Parking
Structures Access to elevators, stairwells and pedestrian pathways should
® be clearly visible from an adjacent parking area. ■
® Avoid hidden recesses. ■
Locate parking areas in locations that can be observed by
adjoining uses. ■
Open spaces shall be clearly designated and situated at
For Common/ locations that are easily observed by people. Parks, plazas,
Open Space common areas, and playgrounds should be placed in the front
Areas of buildings. Shopping centers and other similar uses should
face streets. ■
Other strategy used:
■❑
Evaluation for
Agency Use Only
Bulletin #022 — August 18, 2004 Page 2 of 9 k:\Handouts\CPTED Checklist
Section and ✓ Functional Area Evaluation for
Performance Performance Standard Agency Use Only
Standard
Strategy
M Applicable during Site Plan Review
e Applicable during Building Permit Review
1.3 Common/Open Space Areas and Public On -Site Open Conforms
Space Revise
Provide natural surveillance for commonlopen space areas. _NA
Comments:
Position active uses or habitable rooms with windows adjacent
to main common/open space areas, e.g. playgrounds,
swimming pools, etc., and public on -site open space. ■
Design and locate dumpster enclosures in a manner which
screens refuse containers but avoids providing opportunities to
hide. ■
Locate waiting areas and external entries to elevators/stairwells
❑ close to areas of active uses to make them visible from the
building entry. e
❑ Locate seating in areas of active uses. e
Other strategy used:
1.4 Entrances `Conforms
Provide entries that are clearly visible. _Revise
_NA
Comments:
Design entrances to allow users to see into them before
entering. ■
Entrances should be clearly identified (Signs must conform to
❑ FWCC Section 22-1569(D). Permit Exceptions. (Applicable
during Certi icate of Occztnanc, In n .
Other strategy used:
F
1.5 Fencing _Conforms
Fence design should maximize natural surveillance from the _Revise
street to the building and from the building to the street, and _NA
minimize opportunities for intruders to hide. Comments:
Bulletin #022 — August 18, 2004 Page 3 of 9 k:\Handouts\CPTED Checklist
Section and ✓ Functional Area Evaluation for
Performance Performance Standard Agency Use Only
Standard
Strategy
■ Applicable during Site Plan Review
e Applicable during Building Permit Review
❑ Front fences should be predominantly open in design, e.g.
pickets or wrought iron, or low in height. e
Design high solid front fences in a manner that incorporates
❑ open elements to allow visibility above the height of five feet.
e
If noise insulation is required, install double -glazing at the
❑ front of the building rather than solid fences higher than five
feet. e
Other strategy used:
1.6 Landscaping Conforms
Avoid landscaping which obstructs natural surveillance and _Revise
allows intruders to hide. _-__NA
Comments:
® Trees with dense low growth foliage should be spaced or their
crown should be raised to avoid a continuous barrier. ■
Use low groundcover, shrubs a minimum of 24 inches in
height, or high -canopied trees (clean trimmed to a height of
eight feet) around children's play areas, parking areas, and
along pedestrian pathways. ■
® Avoid vegetation that conceals the building entrance from the
street. ■
Other strategy used:
U
1.7 Exterior Lighting 8 at Building Permit Review _Conforms
Provide exterior lighting that enhances natural surveillance. Revise
(Refer to FWCC Section 22-1635(g)(1) for specific lighting _NA
requirements.) Comments:
Prepare a lighting plan in accordance with Illuminating
Engineering Society of America (IESA) Standards, which
❑ addresses project lighting in a comprehensive manner. Select a
lighting approach that is consistent with local conditions and
crime problems. ■
Bulletin #022 — August 18, 2004 Page 4 of 9 k:\Handouts\CPTED Checklist
Section and ✓ Functional Area Evaluation for
Performance Performance Standard Agency Use Only
Standard
Strategy
X Applicable during Site Plan Review
e Applicable during Building Permit Review
Locate elevated light fixtures (poles, light standards, etc.) in a
❑ coordinated manner that provides the desired coverage. The
useful ground coverage of an elevated light fixture is roughly
twice its height. ■
For areas intended to be used at night, ensure that lighting
❑ supports visibility. Where lighting is placed at a lower height to
support visibility for pedestrians, ensure that it is vandal -
resistant. e
❑ Ensure inset or modulated spaces on a building facade,
access/egress routes, and signage is well lit. e
In areas used by pedestrians, ensure that lighting shines on
pedestrian pathways and possible entrapment spaces. e
Place lighting to take into account vegetation, in its current and
❑ mature form, as well as any other element that may have the
potential for blocking light. e
Avoid lighting of areas not intended for nighttime use to avoid
❑ giving a false impression of use or safety. If danger spots are
usually vacant at night, avoid lighting them and close them off
to pedestrians. e
Select and light "safe routes" so that these become the focus of
legitimate pedestrian activity after dark. ■
❑ Avoid climbing opportunities by locating light standards and
electrical equipment away from walls or low buildings. e
Use photoelectric rather than time switches for exterior
lighting. e
In projects that will be used primarily by older people
(retirement homes, congregate care facilities, senior and/ or
community centers, etc.) provide higher levels of brightness in
public/common areas. e
Other strategy used:
® I Both low level path lights and higher level roadway lighting will be
1.8 Mix of Uses _Conforms
In mixed use buildings increase opportunities for natural _Revise
surveillance, while protecting privacy. _NA
Comments:
Bulletin #022 — August 18, 2004 Page 5 of 9 k:\Ilandouts\CPTED Checklist
Section and ✓ Functional Area
Performance Performance Standard
Standard
Strategy
■ Applicable during Site Plan Review
e Applicable during Building Permit Review
Where allowed by city code, locate shops and businesses on
lower floors and residences on upper floors. In this way,
❑ residents can observe the businesses after hours while the
residences can be observed by the businesses during business
hours. ■
❑ Include food kiosks, restaurants, etc. within parks and parking
structures. ■
Other strategy: used
U
Evaluation for
Agency Use Only
1.9 Security Bars, Shutters, and Doors _Conforms
When used and permitted by building and fire codes, security —Revise
bars, shutters, and doors should allow observation of the street `NA
and be consistent with the architectural style of the building. Comments:
❑ Security bars and security doors should be visually permeable
(see -through). e
Other strategy used:
FEW
Section and ✓ Functional Area
Performance Performance Standard
Standard
Strategy
■ Applicable during Site Plan Review
e Applicable during Building Permit Review
Evaluation for
Agency Use Only
Section 2.0 Access Control
2.1 Building Identification _Conforms
Ensure buildings are clearly identified by street number to _Revise
prevent unintended access and to assist persons trying to find _NA
the building. Identification signs must conform to FWCC, Comments:
Section 22-1569(D). Permit Exceptions.
❑ Street numbers should be plainly visible and legible from the
street or road fronting the property. e
Bulletin #022 — August 18, 2004 Page 6 of 9 k:\flandouts\CPTED Checklist
Section and ✓ Functional Area Evaluation for
Performance Performance Standard Agency Use Only
Standard
Strategy
■ Applicable during Site Plan Review
e Applicable during Building Permit Review
In residential uses, each individual unit should be clearly
numbered. In multiple building complexes, each building entry
❑ should clearly state the unit numbers accessed from than entry.
In addition, unit numbers should be provided on each level or
floor. e
❑ Street numbers should be made of durable materials, preferably
reflective or luminous, and unobstructed (e.g. by foliage). e
For larger projects, provide location maps (fixed plaque
❑ format) and directional signage at public entry points and along
internal public routes of travel. e
Other strategy used:
u
2.2 Entrances _Conforms
Avoid confusion in locating building entrances. —Revise
NA
Comments:
Entrances should be easily recognizable through design
® features and directional signage. (Signs must conform to
FWCC Section 22-1569(D). Permit Exceptions. ■
❑ Minimize the number of entry points. ■
Other strategy used:
2.3 Landscaping _Conforms
Use vegetation as barriers to deter unauthorized access. —Revise
NA
Comments:
❑ Consider using thorny plants as an effective barrier. e
Other strategy used:
u
2.4 Landscaping Location _Conforms
Avoid placement of vegetation that would enable access to a _Revise
building or to neighboring buildings. _NA
Comments:
Bulletin #022 — August 18, 2004 Page 7 of 9 k:\Handouts\CPTED Checklist
Section and ✓ Functional Area Evaluation for
Performance Performance Standard Agency Use Only
Standard
Strategy
■ Applicable during Site Plan Review
e Applicable during Building Permit Review
Avoid placement of large trees, garages, utility structures,
0 fences, and gutters next to second story windows or balconies
that could provide a means of access. ■
Other strategy used:
2.5 Security _Conforms
Reduce opportunities for unauthorized access _Revise
_NA
Comments:
Consider the use of security hardware and/or human measures
❑ to reduce opportunities for unauthorized access. (Applicable
during Certificate of ccu an Inr ection).
Other strata used:
2.6 Signage _Conforms
Insure that signage is clearly visible, easy to read and simple to _Revise
understand [Signs must conform to FWCC Section 22-1569(D). —NA
Permit Exceptions]. Comments:
❑ Use strong colors, standard symbols, and simple graphics for
informational signs. e
Upon entering the parking area, provide both pedestrians and
For Surface ❑ drivers with a clear understanding of the direction to stairs,
Parking and elevators, and exits. e
Parking
Structures In multi -level parking areas, use creative signage to distinguish
between floors to enable users to easily locate their cars. e
❑ Advise users of security measures that are in place and where
to find them, i.e. security phone or intercom system. e
❑ Provide signage in the parking area advising users to lock their
cars. e
Bulletin #022 — August 18, 2004 Page 8 of 9 k:\Handouts\CPTED Checklist
Section and ✓ Functional Area Evaluation for
Performance Performance Standard Agency Use Only
Standard
Strategy
■ Applicable during Site Plan Review
e Applicable during Building Permit Review
❑ Where exits are closed after hours, ensure this information is
indicated at the parking area entrance. e
Other strategy used:
Section 3.0 Ownership
3.1 Maintenance
_Conforms
Create a "cared for" image
_Revise
_NA
Comments:
Ensure that landscaping is well maintained, as per FWCC
❑ Section 22-1569, in order to give an impression of ownership,
care, and security. (Ongoing).
Where possible, design multi -unit residential uses such that no
❑ more than six to eight units share a common building entrance.
1
Other strategy used:
HE Excellent maintenance of first phases will continue in Phases II and III.
3.2 Materials
_Conforms
Use materials, which reduce the opportunity for vandalism.
Revise
—NA
Comments:
Consider using strong, wear resistant laminate, impervious
glazed ceramics, treated masonry products, stainless steel
❑ materials, anti -graffiti paints, and clear over sprays to reduce
opportunities for vandalism. Avoid flat or porous finishes in
areas where graffiti is likely to be a problem. e
❑ Where large walls are unavoidable, refer to FWCC Section 22-
1564(u) regarding the use of vegetative screens. e
Common area and/or street furniture shall be made of long
❑ wearing vandal resistant materials and secured by sturdy
anchor points, or removed after hours. e
Other strategy used:
Bulletin #022 — August 18, 2004 Page 9 of 9 k:\Handouts\CPTED Checklist
CITY OF
� Federal Way
Centered on Opportunity
April 27, 2018
Austin Groves
R J Development
401 Central Street SE
Olympia, WA 98501
austin@rjdevelopment.com
CITY HALL
33325 8th Avenue South
Federal Way, WA 98003-6325
(253) 835-7000
www.cityoffederalway.com
Jim Ferrell, Mayor
RE: File #18-101323-00-AD; TECHNICAL REVIEW COMMENT LETTER
Village Green Memory Care, *No Site Address*, Parcel #302104-9146, Federal Way
Dear Mr. Groves:
The City is in receipt of your March 23, 2018, application for a site plan modification to the Village
Green Phase II & Phase III Process IV land use approval at the above -mentioned site.
ADDITIONAL INFORMATION REQUESTED
The following items are based on the initial technical review of the Administrative Decision application.
1. The total number of units has changed from what was approved under the Process W Hearing
Examiner's Decision. The total number of units cannot exceed 367 units. The additional units for the
Memory Care Facility must be deducted from the Phase II building unit count. Please revise the unit
count on Sheet AD2 accordingly.
2. The previous parking needs and trip generation report, prepared by Transportation Solutions Inc.,
dated November 5, 2008, should be revised to reflect the needs of the proposed Memory Care Facility
and community building. Further, the parking study should be revised to identify staff parking needs
and reflect PM peak hour parking needs.
3. Under FWCC section 22-640 note #5, no fagade of any structure may exceed 120 feet in length;
however, under note #3, the City may permit or require modification of dimensional and site design
requirements based on the following criteria:
a. The specific nature of the occupancy and the persons that will be housed in the proposed
development.
b. The size of the dwelling units or occupancy rooms or suites and the specific configuration of
and facilities within these units, rooms or suites.
c. The impacts on nearby residential uses of the proposed development.
d. The architecture, site design and other design features of the proposed development.
Provide written explanation as to how the building meets modification criteria.
Mr. Groves
April 27, 2018
Page 2
4. As noted in the preapplication conference letter, the formal application must include a written
narrative identifying how the project complies with all applicable guidelines, as detailed in the FWRC
Chapter 19.115 (FWCC Chapter 22, Article XIX), `Community Design Guidelines.'
5. The approved landscape plans depict 20 feet of Type II landscaping along the south property line
abutting the single family houses. The submitted landscape plans do not meet this standard. Based on
the discussion at the meeting, held on Thursday, April 26, 2018, you indicated that revised
landscaping plans would meet this requirement. Please submit the revised landscape plans for review.
Pursuant to FWRC 19.125.100 (FWCC § 22-1570) any landscape modification requests must be
submitted in writing and reviewed as part of the AD approval.
6. Provide a description of the community building and who will be utilizing the building.
CLOSING
Administrative Decision applications are deemed complete at the time of submittal. Please provide a
revised site plan and landscaping plan with a completed project resubmittal sheet (enclosed). When
submitting the requested information, please provide five copies of the revised drawing and a letter
addressing each review comment. If an applicant fails to provide additional information to the city,
pursuant to FWRC 19.15.050, within 180 days of being notified that such information is required, the
application will be deemed null and void and the city shall have no duty to process, review, or issue any
decisions with respect to such an application.
If you have any questions regarding this letter, please feel free to contact me at 253-835-2641 or
becky.chapin@cityoffederalway.com.
Sincerely,
Becky p Cha i
Associate Planner
enc: Resubmittal Form
c: Brooks Powell, brooks@powell-homes.com
Hal Duncanson, haroldd@duncansonco.com
18-101323-00-AD Doc LD. 77655
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT DEPARTMENT
DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL
DATE: March 29, 2018
TO: Cole Elliott, Development Services Manager
Peter Lawrence, Plans Examinef
Rick Perez, City Traffic Engineer
Brian Asbury, Lakehaven Water & Sewer District
Chris Cahan, South King Fire & Rescue
FROM:
FOR DRC MTG. ON.
FILE NUMBER(s):
RELATED FILE NOS.:
PROJECT NAME:
PROJECT ADDRESS:
ZONING DISTRICT. -
PROJECT DESCRIPTION:
LAND USE PERMITS.
PROJECT CONTACT:
MATERIALS SUBMITTED:
Becky Chapin, Associate Planner
April 19, 2018 — Internal Discussion
18-101323-00-AD
YA
08-105555-00-UP & 17-102079-00-PCB[
j
Village Green Memory Care 13
Parcel # 302104 9146
Request for minor modification to approved site plan amending number of
cottages and adding memory care and community buildings.
Administrative Decision
Austin Groves �/f�
GAA9-'
RJ Development
401 Central St SE
Olympia, WA 98501
• Request for Administrative Decision
• Stormwater Management Narrative
• Hazardous Materials Inventory/Wellhead Checklist
■ CPTED Checklist
• Water & Sewer Availability
• Minor Modification Plan Set
\
To: Kevin Peterson
From: Harold Duncanson
Date: 2/23/18
Subject:
DUNCANSON
Company, Inc.
Village Green Memory Care
Stormwater Management Narrative/
Abbreviated Technical Information Report (TIR)
RECEIVED
MAR 2 3 2018
The Village Green Memory Care project is a 64-unit apartment type building located on
the Cottages West portion of the Village Green Campus (Village Green Phase III). Original
site development for this property was done between 2005 and 2008. Land use approval
for this site was renewed in 2010 (6/l/2010). That approval vested this site to the 1998
KCSWDM for the first 5 years. If construction of the overall project was not complete
within the first 5 years, then whatever drainage standards adopted by the City at the time
of first building permit completeness was to apply. See attached excerpts from the May
18, 2010 staff report to the Hearing Examiner (08-105555-00-UP). The first permit was
for Cottages 17-20 in July 2016. At that time, the City's adopted drainage standards were
the 2016 KCSWDM with Federal Way Addendum. However, these conditions were
primarily intended to address runoff from Village Green Phase II. This current memory
care building is located within the Village Green Phase III basin. Runoff from this portion
of the site is treated with an existing wet pond followed by full infiltration.
Following is a summary of how the project meets the Core and Special Requirements of
the 2016 KCSWDM.
CR1—Discharge at Natural Location
Project runoff drains to an existing infiltration pond. No change.
CR2—Offsite Analysis
Previously prepared. See 08-105555-00-UP.
CR3—Flow Control
Project is in a Conservation Flow Control area; however, all runoff will be fully infiltrated
in an existing infiltration pond. The pond was designed using the same methodologies
required by the 2016 KCSWDM.
The memory care building represents approximately 9,000 SF more impervious area than
the 4-plex structures (cottages) originally planned for this portion of the site. To balance
this slight overage, two cottage structures were designed to provide full infiltration
drywells to independently mitigate approximately 9,600 SF. See permit numbers 17-
104190-MF and 17-104193-MF.
145 SW 155" Sheet Suite 102 Seattle, Washington 98166
Phone 206.244.4141 Fax 206.244.4455 Web www.duncansonco.com
ICIVIL ENGINEERING
2/23/2018
Page 2
It is worth noting that the infiltration pond was designed to infiltrate runoff from about
290,000 SF (6.6 ac) of impervious surface. The basin is approximately 60% built out. A
site recon performed January 7, 2018 did not reveal any signs of water having reached a
depth of more than several inches, despite considerable rain in the preceding months. The
infiltration pond appears to be performing as intended.
CR4—Conveyance System
The conveyance systems are already in place for this project. No new conveyance systems
are proposed. Two catch basins will be slightly relocated to accommodate the driveway
loop.
CR5—Erosion and Sediment Control
A project specific ESC Plan and SWPPP have been prepared and are included with the
application materials.
CR6—Maintenance and Operations
Maintenance and Operations agreements are already in place.
CR7—Financial Guarantees and Liability
The only financial guarantee anticipated is site restoration. A bond quantities worksheet
is attached.
CR8—Water Quality and FWRC 19.30.120
The project is located in an Enhanced Basic Water Quality Treatment area. While
considered multifamily, the project is exempt from Enhanced Basic requirements since
runoff is infiltrated. See KCSWDM Section 1.2.8.1.A Page 1-73, Exception 2: "The
Enhanced Basic WQ menu as specified above for certain land uses may be reduced to the
Basic WQ menu for treatment of any runoff that is infiltrated per the standards of Section
5.2. " The existing infiltration pond is just over '/a mile upgradient from a Hylebos Creek
tributary. See attached Figure A.
Basic Water Quality Treatment is provided by the existing wetpond and the facility
conforms to current requirement. In other words, the facility is not nonconforming with
respect to application of FWRC 19.30.120.
CR9-Flow Control BMPs
The Flow Control BMP requirement of the 2016 KCSWDM is exempted since runoff
drains to an infiltration facility. See KCSWDM Page 1-83: "Any impervious surface
served by an infiltration facility designed in accordance with the flow control facility
requirement (Section 1.2.3.1), the facility implementation requirements (Section 1.2.3.2),
and the design criteria for infiltration facilities (Section 5.2) is exemptfrom the flow control
BMPs requirement. "
2/23/2018
Page 3
SRl—Other Adopted Area -Specific Requirements
Project is located in the Hylebos Creek Basin. Full infiltration through the existing pond
meets the basin standards.
SR2—Flood Hazard Area Delineation
Not applicable.
SR3—Flood Protection Facilities
Not applicable.
SR4—Source Control
The only anticipated structural source control is to utilize covered dumpsters. Non-
structural source controls will include professionally maintained landscaping and pest
control, which is already employed on the campus. Other source controls are discussed in
the SWPPP.
SR5--Oil Control
Not applicable —Project is not a high use site.
M
yet un-built under existing approvals. Lastly, the applicant proposes to increase the
Phase Il density and construct an additional nine units as provided pursuant to
affordable housing regulations.
3) The land use application for Village Green Phase II and Phase III (Cottages West) is
vested to the Federal Way City Code (FWCC) that was in effect on December 15,
2008, the date that the land use application was determined to be complete. On May 9,
2010, the City reorganized the Federal Way City Code (FWCC) into the Federal Way
Revised Code (FWRC). This project is only subject to those applicable portions of the
FWRC that are consistent with the December 15, 2008 FWCC.
4) The site is located within the High Density Residential designation of the FWCP and
within both the RS-7.200 and RS9.600 Single Family Residential classifications. The
proposed use is consistent with the FWCP and associated applicable policies. FWRC
19.200.100 allows Senior Citizen housing within the RS zone subject to Process IV
approval by the Hearing Examiner, following a public hearing.
4) All appropriate public notices were delivered in accordance with the requirements of
the FWRC. No comments were received.
5) Pursuant to SEPA, RCW 43.21C, the Director of Community Development Services
issued an Environmental Determination of Nonsignificance (DNS) on March 13, 2010.
Affected agencies, tubes, and the public were offered the opportunity to comment on or
appeal the determination for 28 days. No comments or appeals were submitted by the
appeal deadline of April 12, 2010.
6) The subject property includes a sloping forested ravine, a manmade closed depression,
and open meadows. During initial development, much of the steep sloped area was re -
contoured, flattened; and stabilized based on geotechnical recommendations.
7) Overall site design retains and incorporates much of the existing trees and vegetation as
a site amenity. Additional trees and landscaping will be installed to compliment the
existing vegetation, and the extensive use of native plant materials will increase
wildlife habitat opportunities.
8) The drainage basin for the Phase III (Cottages West) portion of the Village Green site
is within a manmade closed depression. A combined storm drainage system created in
the manmade depression is shared by Cottages West and other adjacent developments.
Storm drainage for the eastern portion of the site is directed into an existing treatment/
detention facility located in the Phase I portion of the site. This system was constructed
prior to adoption of the 1998 King County Surface Water Design Manual (KCSWDM).
To address water quality standards, water quality treatment is required for the entire
Village Green site (excluding the Cottages West portion). In response to the applicant's
request of an additional five year construction timeline beyond the five year
construction period allowed under Process IV, the Public Works Department
recommends that the storm drainage system conform to those drainage system
requirements and standards adopted by the City on the date that the first building
permit application for the Phase II project is determined to be complete.
Staff Report to the Federal Way Hearing Examiner
Village Green of Federal Way, Phases Il and III
Page 16
File No. 08-105555-00-UP/o,,,. LD5384z
affordable housing units. Affordable housing units required for Cottages West are
provided in Village Green Phase II. A covenant to establish affordable housing units
within Village Green Phase II in perpetuity has been recorded at King County.
17) As proposed by the applicant and as recommended by the City, the requested phased
construction timeline of ten years (as opposed to the typical five year construction
timeline from the date of Hearing Examiner's approval) for both the Village Green
Phase II and Phase III (Cottage West) developments, is authorized by FWRC, is
consistent with the public interest by improving construction efficiency and response to
market conditions, and as recommended by the City, does not conflict with any existing
or anticipated applicable code, policy, or regulation.
18) Development of the site, as proposed and conditioned and subject to all applicable
development codes and regulations during engineering plans review, will ensure that
the public health, safety, and welfare is protected.
19) The proposed development is consistent with Hearing Examiner decisional criteria
required under FWRC 19.70.150 and 19.200.100.
B. Conclusion
The proposed Village Green Phase II and Phase III (Cottages West) development will
comply with all applicable goals, policies, and regulations of the FWRC, and with the goals
and objectives of the FWCP, provided that all recommended conditions of approval are met.
XVI. RmOAMENDATION
It is recommended that the application be approved as proposed, subject to the following
conditions:
If the Village Green Phase II project is not fully constructed or substantially complete within
the City code based five-year timeline granted under Process IV Approval, then the
applicant shall design the storm drainage system to conform to those drainage design
requirements and standards adopted by the City on the date that the first building permit
application(s) for the Phase II project is determined to be complete. This condition applies to
any extension beyond the five year timeline granted under Process IV pursuant to Federal
N'ay Revised Code (FWRC) 19.15.110.
2. If any building permits for the Village Green Phase II and Phase III (Cottages West) project
have not been issued within the City code -based five-year timeline granted under Process IV
Approval, the applicant shall fund preparation of a new concurrency analysis. This analysis
must demonstrate that adequate capacity for the un-built portions of the project still exists
for the remainder of the project. In the event that there is not adequate capacity, the applicant
shall be required to construct whatever mitigation measures are necessary to meet the
adopted Level of Service (LOS) at any failing intersection.
3. If any building permits for the Village Green Phase II and Phase III (Cottages West) project
have not been issued within the City code -based five-year timeline granted under Process IV
Approval, the applicant shall make payment of applicable transportation fees/concurrency
Staff Report to the Federal Way Hearing Examiner Page 18
Village Green of Federal Way, Phases E and III File No. 08-105555-00-UP/Duc.I.D53842.
I Feet
Measurement Result
1,353.5 Feet
i
c y
i
Man'ake
sw 3344St West Hylebos
4�0
s
1
S h ✓
Figure A —Distance to Aquatic Life Freshwater
H,
Hit]
F
Construction Stormwater
Pollution Prevention Plan
(CSWPPP)
Village Green Memory Care
Prepared: February 23,2018
DO Project: 98480
I.
1110
DUNCANSON
C"fgw"Y Inc.
145 SW 155`h Street, Suite 102
Seattle, Washington 98166
(206) 244-4141
Part A — ESC Plan Analysis and Design
1. Clearing Limits
Clearing limits have been delineated on the TESC Plans.
2. Cover Measures
Cover measures have been delineated on the TESC Plans.
3. Perimeter Protection
Perimeter Protection will be used as Primary Treatment and will consist of a Silt
Fence. The location and installation has been specified on the TESC Plans.
4. Traffic Area Stabilization
A stabilized construction entrance will be used to limit sediment transport. The
entrance location and details are shown on the TESC Plans.
Sediment Retention
The cleared area is approximately 41,000 SF. Sediment retention is not required
since perimeter protection is used as Primary Treatment (in accordance with 2016
KCSWDM Appendix D, Section D.2.1.5). However, a sediment trap is proposed
as a conservative measure. Due to sand and gravel soil conditions, little runoff is
expected from exposed soils. Additional infiltration opportunity will be provided
by the sediment trap. A VO HM analysis was run to determine Q2 for the purpose
of sizing the sediment trap (results below). Since the sediment trap will be needed
when soils are exposed, and since site soils are relatively permeable, cover was
assumed to be 0.5 ac bare soil (lawn) and 0.5 ac impervious. Sediment trap size
(KCSWDM D.2.1.5.1) V = 2xQ2/0.00096 = (2)(0.194)/0.00096 = 400 SF.
• BMP C240: Sediment Trap
Flow Frequency
Flowtcfsi
Predeveloped
2 Year =
0.1938
5 Year =
0.2520
10 Year =
0.2941
25 Year =
0.3515
50 Year =
0.3974
100 Year =
0.4461
6. Surface Water Collection
Surface water collection is also not required since perimeter protection is used as
Primary Treatment (in accordance with 2016 KCSWDM Appendix D, Section
D.2.1.6). However, interceptor swales are shown to collect runoff and route it to
the sediment trap until such time as the basement floor is constructed.
7. Dewatering Control
Dewatering is not anticipated; however, if trench dewatering is necessary, the
water must be pumped to a trap or vegetated area.
8. Dust Control
Dust control measures have been addressed on the TESC plans.
9. Flow Control
Exposed soils are expected to be sand and gravel,with little runoff. The sediment
trap will also provide some opportunity for infiltration and flow attenuation.
Once exposed soils are covered with impervious surfaces, then flow control will
be provided by the downstream facility.
10. Control Pollutants
The following source controls shall be implemented (refer to the 2016 King
County Stormwater Pollution Prevention Manual):
- A-4: Storage of Soil, Sand and Other Erodible Materials
- A-11: Cleaning or Washing of Tools and Equipment
- A-17: Fueling Operations
- A-20: Concrete and Asphalt at Temporary Sites
A note is included on the plans that specifies that the contractor shall develop a
spill prevention plan and maintain appropriate spill response supplies for any
toxic or hazardous liquids stored or used on site.
11. Protect Existi ng and Proposed Flow Control BMPs
No Flow Control BMPs exist or are proposed near the project site.
12. Maintain BMPs
The TESC/SWPPP BMPs shall be maintained through the life of the project. When
temporary BMPs are removed near the end of the project, remaining disturbance
shall be stabilized by seeding and mulching or other appropriate permanent
measure.
13. Manage the Project
Coordination and timing of site development will be performed to correctly manage
the project to assure ESC measures are implemented properly. The contractor shall
designate a TESC supervisor at or before the precon meeting. TESC supervisor
information shall be posted as required by the City.
Part B — SWPPS Plan Design
The following brief narrative discusses compliance with the minimum pollution -generating
activities typically associated with construction as required for the SWPPS plan:
• Stora a and Handling of Li ukls
Most if not all structures will be prefabricated and prefinished. No on -site use of
paints, solvents, pesticides, form oils and concrete admixtures are anticipated. If
any liquids and other hazardous materials are kept on site, they should be covered
or stored in a manner to minimize any exposure to rain or stormwater.
• Storageand Stockpilin of Construction Materials and Wastes
Storage and stockpiling of materials may occur, but are expected to be very minimal
and short term. Most materials are anticipated to pose little or no threat to
stormwater. Plan notes specify covering exposed soils/stockpiles. A note on the
plan also calls for covering other stored supplies or materials that could pollute
runoff.
• Fuelin
Fueling is expected to be provided by service trucks. On -site storage of fuel is not
anticipated. A note is included on the plans specifying lighting if fueling will occur
at night.
■ Maintenance Re airs and Storage of Vehicles and Equipment
A note is included on the plans that specify the use of drip pans or plastic when
maintenance is performed.
• Concrete Saw Cutting, Slurry and Washwater Disposal
A sump is shown on the plans for slurry and washwater disposal.
• Handling of pH Elevated Water
Stormwater is not anticipated to be subjected to pH elevating circumstances.
• A > >iication of Chemicals including Pesticides and Fertilizers
No pesticides are anticipated. Disturbed soils are anticipated to be stabilized by
hydroseeding and landscaping. No other fertilizer application is anticipated.
Project Name
VILLAGE GREEN
PHASES II & III - EXTENSION
VILLAGE GREEN OF FEDERAL WAY,
Applicant A RETIREMENT CAMPUS LLCM
Project Location 1 ST AVENUE S & SW 356TH STREET Tracking No.
TYPES AND QUANTITIES OF HAZARDOUS MATERIALS
Please provide the approximate quantity of the types of hazardous materials or deleterious substances
that will be stored, handled, treated, used, produced, recycled, or disposed of in connection with the
proposed activity. If no hazardous materials will be involved, please proceed to Section IV.
MATERIAL
(I ] Acid or basic solutions or solids
LIQUID (gallons)
SOLID ( ounds)
(2) Antifreeze or coolants
(3) Bleaches, peroxides, detergents, surfactants,
disinfectants, bactericides, algaecides
5
(4) Brake, transmission, hydraulic fluids
(5) Brine solutions
(6) Corrosion or rust prevention solutions
(7) Cutting fluids
(8) Deicing materials
(9) Dry cleaning or cleaning solvents
(10) Electroplating or metal finishing solutions
(11) Engraving or etching solutions
(12) Explosives
(13) Fertilizers
(14) Food or animal processing wastes
(15) Formaldehyde
(16) Fuels, additives, oils, greases
(17) Glues, adhesives, or resins
(18) Inks, printing, or photocopying chemicals
(19) Laboratory chemicals, reagents or standards
(20) Medical, hospital, pharmaceutical, dental, or
veterinary fluids or wastes
< 5 per week
(21) Metals (hazardous e.g. arsenic, copper,
chromium, lead, mercur
y. silver, etc.)
(22) Paints, pigments, dyes, stains, varnish, sealers.
10
(23) Pesticides, herbicides or poisons
(24) Plastic resins, plasticizers, or catalysts
(25) Photo development chemicals
(26) Radioactive sources
(27) Refrigerants, cooling water (contact)
(28) Sludges, still bottoms
(29) Solvents, thinners, paint removers or strippers
(30) Tanning (leather) chemicals
(3 1 ) Transformer, capacitor oils/fluids, PCB's
(32) Waste oil
(33) Wood preservatives
(34) List OTHER hazardous materials or deleterious
substances on a separate sheet.
Bulletin #056 — November 24, 2004 Page 2 of 3 k:\Handouts\Hazardous Materials Inventory Statement
VILLAGE GREEN VILLAGE GREEN OF FEDERAL WAY,
Project Name PHASES II & III - EXTENSION ® Applicant A RETIREMENT CAMPUS LLC LJ
Project Location I ST AVENUE S & SW 356TH STREET Tracking No,
IV. FURTHER INFORMATION
Provide the approximate quantity of fill and source of fill to be imported to the site.
Approximate Quantity of Imported Fill
Source of Fill
None
N/A
Check box #1 if you do not plan to store, handle, treat, use, produce, recycle, or dispose of any of the
types and quantities of hazardous material or deleterious substance listed in Section M. Check box(s) #2
through #5 (and fill in appropriate blanks) of the below table if they apply to your facility or activity.
The proposed development will not store, handle, treat, use, produce, recycle, or dispose of any of
#1 [ ]
the types and quantities of hazardous materials or deleterious substances listed above.
#2 [ ]
Above ground storage tanks, having a capacity of gallons will be installed.
#3 [ ]
Construction vehicles will be refueled on site.
Storage within wholesale and retail facilities of hazardous materials, or other deleterious
#4 [ ]
substances, will be for sale in original containers with a capacity of _ gallons liquid or
pounds solid.
The presence of chemical substances on this parcel is/will be for "temporary" non -routine
#5 [■]
maintenance or repair of the facility (such as paints and paint thinners) and are in individual
containers with a capacity of 10 gallons liquid or -- pounds solid.
Check any of the following items that currently exist or are proposed in connection with the
development of the site.
#1 [■]
Stormwater infiltration system (e.g., french drain, dry well, stormwater swale, etc.)
#2 [ ]
Hydraulic lifts or elevator, chemical systems, or other machinery that uses hazardous materials
#3 [ ]
Cathodic protection wells
#4 [ ]
Water wells, monitoring wells, resource protection wells, piezometers
#5 [ ]
Leak detection devices, training for employees for use of hazardous materials, self-contained
machinery, etc.
SIGNATURE
I,-
RJ Development c/o Austin Groves
Print Name
3/21/18
Date
If you have any questions about filling out this application form, please call the Department of Community
Development Services at 253-835-2607. Please be advised that an application for a development permit
lacking the required information will not be accepted.
Bulletin #056 — November 24, 2004 Page 3 of 3 k:\Handouts\Hazardous Materials Inventory Statement
108228.7515'
i 47° 17' 12.28483" N
:.�
J� 27 1921049017
H 125 h `
8 28 29
y ti
��-- 1,IQar _aZa°e ti 2(;21US9r)1$
8724500080 ? '?1-4 P2V 5
8724500070 V Rafrng.• l k �
310530 �-� 8724500090 �O� 3021049162
ti
d
146
8720.500060 8724500100 � vn
a+:
A 30 049025 y h Maio
10520 `Ov 5215 ti 292104
8724500050
8 8724500110 o p�
049161 R S 9.6 3021
87245A0046 d� 140
8724500030
8724500020 cc RS9w6
1960 QV 8724500120 3up9 3su3 7sv R S 2
�sw3 > 2921049031
8724500010 .[' "d Q 35316
8724500130 Village st �—
Green (j)
4 r ,
4
8724500150 3021049146
8724500140 3W �m 2921049069
302104902435416 35326
8724500160 35419
8724500170 2921049078
35400
8724500180
2921049067
872459019➢
35414
8724500200
9724500210 R A 9 .
J 35422
2921049061 '2
8724500220
35430
, 357ig
u 7397000010 - �I
p 35512 7387000110 7387000060 7387000070 f
p JOHN ROE 214
7387000020 7387000050 �f
35512 224 S 355TH PL 3021049017
N 93 35506
7387000030 RS9.6
35520 7387000090 7387000080 Q 2921049076
7387000100 P16 207 c 35454 - y
7387000040 223 z R S 7.2 =
35528 N
SW 356TH ST S q
O Ij -
Z
0 O
Z
0 Z
r 1, W O
O J F-
w U O
Of In a-
LLI
LE e
L
CC r� m
`o
W
_v'
0
`W 9
/ S�y
� �mm
J earn
rv�lI
gI r
W $
U - y
Y)
W
w
a g• �, c
e
E
�10
1 N
a'
C �1
O
FVI H?� J Zw V ** Ib
z¢ 3 0 ¢ Z
w: L v ��� m. N a$$3x•r rn C
Z zNW NM Li < C]..~•.: •':1 N m Ek�
LJ..I JOT (nO mZO W U a J 0 O� M V1 W N z ly � 1 �p gq C $p- LO
lLl } ODOv �h- n LAM �O N Lr d' y h / o b01q: 'Q �I Z w
LLI ¢ O I nj r J o w U U w ONZ , •'',;' nnhn ,n �:
=OOw U 100 Hw OU OIY¢ l� N �m N u�
�wvwio7¢ woo SOLL,N �� '-`Nw' S^JfY. 1Si
J h- m U 0 : VOi , Ln N UI Z Q O¢ Q .. y S -3AV 1 t,,
Q zo =�Zw
�. ow¢U wwz�O~tlr� Q��Z'I C2 ;5,_.- •M '3AV ON.-
p O ¢ w0 U I- M rp O 'Y' W w O
Z¢In , 0
OZ ~ woOwnou,•'•.Q¢ ' r �' na Ass'iAf 13Ld j o
(.i V) W- F- � U) ¢ O W w ': {Y �.Z � a 2. ;: • MS '3%Y RHI
a aa0¢wN ¢oUUm� '�C W:[T. ;* s \\\\\\ \\\ 0 a aj
z
w;•sw _J} O Q ¢ Q] '' '0 v h1S•'�d Hlb
zLo
o>-�Qwa �¢r�V+ M �d NlLLIs V w m
w z o 0 a: V) U o ~n d > s !'6 :w it � � M 31q N1s
Boa �} ov ncwi?w^ uwzaG•„-
w > I w O - ILI O (%] m lal = y•'.., Z # 1 1�1;! ' y u'
fn=zCYw ��=cro�¢O 07NI!~ ;•,MS'3AYP44
4 F 3 w> li d�� 0 in EL (/} n- w a Y- m
J on¢F�w nw¢zz ¢vr7�Gn L7 n ai d
„xm�¢o a=wo_�q �� �a M133AYsu.B•. i
4]�NOI-JU¢N(7 �U� 5?
Y,' Y
MS 3AV 1Sl
3z
7'.4'..
].sz•scs :501.0r.law _ —
£� Ryan
! a z �° I�,, �: _ ' • `{a), I9'86h (0).CS'!5!
l,Oc.los
�z
1 'K
�yxW �• 3F'�' • �
't F I,j N 1,. I D
Q N J v I V/
ink
10
a Z J a
I W i.ffsvRl v Z I cn
vy 2 `n .-.• h- o rn
Mo d
ztsp
of Iri m
On 01-
iX
stl ro,'di` '
W M r`7 ? .f , ¢¢ 5syp� iy •(�) M,zs fz.los j
m _ 3FNT uo rrsra/t 1 �j' a°i
w W _ (a]. 'uac . • +•r, fy].sr'!sr„ LL 3,zs,r:tlau
ibYL�:lcs 3,asca.,ow — {a],ao c _
�tv]Sb'^[Y•(w],lrooz a,xo,st.wN
'3AbI (aos l
¢ MS
V :dm YhZ�
m w I Q -� aNZ o
o I w v40 I �_ arozw a- NZo
r J,• '• Z VI ''4 QV1WDZ TEy W�UZ
@ O U W VI S VI O
O I
4d ZT w ~ ti ( Y D I" ~ Oa U , Ja0 - '� +y6 VI ycZZ WU
10
L ro; }� ooaNi z a m-J zza
am I Fr• f oo\¢r = 17 0 �wca oa
�. O 0 z
z aZ
w_ wit { O "+ia wz
;? ' �w q I O DUa I-
F IZZ
'J).!s' O�
(j�68lp�r,
N .tip.. Dn 4i',A� i
>; Zg. �.;,, flu
m `^ ,N %j S�.• r gyp+ a
Ili L3
U_Na p uul a ro
0 rml�Q•Zo u: oo� Q �� � zl2u v �Ma4 n as
C� f� �I[[LL
0NW;T ¢ N NNN NOytUH my C) Vim'f?- IQ� Za,yq tQ f U O' tQJOQC]R �.li14� O� D� J O S2V Yj x-ltiN
4•L 7 E'- �ie'i M co
\ �I V)v0
���nmo 11O n I a j: 3�U w n li_C]V rcri
D ==u; ui MS 3AV Hit
w
M„Sl,4Z.las --
,RI ov,�,,y7�/ 19 � "8 1J12r1
! /Ln
i7].o! occ r WC�J.+s'os! [rr].II sga
ooI = I �.
v (yZ3A NI )
caa ur mI a v a¢�
�' YTV3S DIHdVHD
RECEIVED REQUEST FOR �NIINISTRATivE DECISION
�� ® DEPARTMENT OF COMMUNITY DEVELOPMENT
CITY OF 33325 8`b Avenue South
Federal Way MAR 2 3 2018 Federal Way, WA 98003-6325
253-835-2607;Fax 253-835-2609
CITY ()F FEDf~M WAY www.cit offCdCTaiwa .com
()OMMUNI.7y oEVELOPMI;NT
FILE NUNIBER 1 _U -,J_ iJ f ,� Date
Applicant
NAME
PRIMARY PHONE
360-528-3343
Austin Groves
BUSUMSS/ORGAMUTION
ALTERNATE PHONE
360-878-2968
RJ Development
MAMUIG ADDRESS
E-MAIL
401 Central St. SE
austin@rjdevelopment.com
CITY STATE ZIP
FAX
Olympia WA Olympia
Property Address/Location 35404 2nd Ave. SW, Federal Wa WA 98003.
Village Green Retirement Campus of Federal Way
Description of Request Administrative amendment of reviously approved Process IV Site Plan. New plan amends
the number of cottages planned and adds -a 42 unit/64 bed Memory Care building as well as a Communit .
Building for the benefit of the Independent Living cottages on site.
List[Describe
For Staff Use
❑ Code Interpretation/Clarification
❑ Critical Areas Letter/Analysis/Peer Review
❑ Request for Extension (Land Use/Plat Approval)
Revisions to Approved Permit
❑ Tree Removal
❑ Zoning Compliance Letter
- No Fee
- No Fee (Actual Cost if Applicable)
- Check Current Fee Schedule
- Check Current Fee Schedule
- No Fee
- Check Current Fee Schedule
Bulletin #079 —January 4, 2016
Page 1 of 1
k:\Handouts\Request for Administrative Decision
'ok
CITY OF 40'::tt=P
Federal Way
APPLICATION NO(S)
MASTER LAND USE APPLICATION
Project Name Village Green Phase II & III Administrative Site Plan Review
Property Address/Location 35404 2nd Ave. SW, Federal Way, WA 98003.
Parcel Number(s) 3021049146
DEPARTMENT OF COMMUNITY DEVELOPMENT
33325 8`h Avenue South
Federal Way, WA 98003-6325
253-835-2607; Fax 253-835-2609
www. c i tvo f federa l way. com
Date 3-23-18
Project Description Administrative Amendment of previously approved site plan to include Memory Care building
and Community building and reducing the number of cottages.
PLEASE PRINT
Type of Permit Required
Annexation
Binding Site Plan
Boundary Line Adjustment
Comp Plan/Rezone
Land Surface Modification
Lot Line Elimination
Preapplication Conference
Process I (Director's Approval)
Process II (Site Plan Review)
Process III (Project Approval)
x Process IV (Hearing Examiner's Decision)
Process V (Quasi -Judicial Rezone)
Process VI
SEPA w/Project
SEPA Only
Shoreline: Variance/Conditional Use
Short Subdivision
Subdivision
Variance: Commercial/Residential
Required Informatiion
Residential RS7.2 Zoning Designation
Comprehensive Plan Designation
Value of Existing Improvements
11,900,000 Value of Proposed Improvements
International Building Code (IBC):
11, Condition 2, S2 Occupancy Type
V-A Construction Type
Applicant
Name: RJ Development
Address: 401 Central St. SE
City/State: Olympia, WA
Zip: 98501
Phone: 360-528-3343
Fax:
Email: austin@rjdevelopment.com
Signature: ,�,, t f�(�Z"Oy—
Agent (if different than Applicant)
Name: RJ Development
Address: 401 Central St. SE
City/State: Olympia, WA
Zip: 98501
Phone: 360-528-3343
Fax:
Email: austin@rjdevelopment.com
Signature:
Owner
Name: Powell Family Land Company, LLC
Address: P.O. Box 98309
City/State: Des Moines, WA
zip: 98198
Phone: 206-824-8001
Fax:
Email: brooks@powel1-homes.com
Signature: Austin Groves - Owners Agent
0 w wf
Bulletin #003 — January 1, 2011 Page 1 of 1 k:\Handouts\Master Land Use Application
44%�
CITY OF MEMORANDUM
Federal Way Community Development Department
To: File 17-102079 Village Green Memory Care Facility
From: Robert "Doc" Hansen, Planning Manager
Subject: Interpretation of Recent Proposal for Memory Care Facility and Conformance with
Previous Decisions
Date: June 30, 2017
The question has been raised regarding whether a Process IV public hearing is necessary to permit a
"memory care facility" within a previously approved proposal designed to serve senior or retired
individuals. The proposal was initially made to provide "cottage -type" residences, many of which were
constructed, and eventually were proposed and approved for larger occupancy designed "cottages" to
serve more individuals within each unit.
History of the Pro'ect and Current Proposal,
The originally approved project is named Village Green and was first brought before the Hearing
Examiner through a Process IV in 1995 under "Village Green, Phase I." The hearing examiner process at
that time recommended approval or denial to the Council with Council making final decision. The Phase
I proposed 90 senior citizen residential units on 13.5 acres at South 336 Street and First Avenue South.
The Council granted conditional approval for Phase I and after conclusion, the applicant requested
approval of Village Green Phase II in 1998. Phase II proposed the construction of 228 senior citizen
residential units on the southerly six acres of the original site. A public hearing was held on August 25,
1998 and the decision for approval by the Hearing Examiner was made on September 9, 1998. The
decision approved the construction of seven buildings with approximately 32 units in each building,
providing both independent and assisted living accommodations. No opposition was presented at the
hearing towards the project. At the time of the approval, the adjacent, surrounding land uses consisted
of a mixture of residential uses of varying densities and institutional uses, including a US West
Communications building and a school.
In 2002 the applicant sought construction extension and requested approval of "Cottages West," forty
(40) of the units be constructed in 16 buildings. This part of the project is later to be sometimes
referenced as "Phase III" of the project. The extension and amendment was approved in April of 2002
by the Hearing Examiner of the unbuilt project.
As a result of poor market conditions, the applicant again sought, and received, approval of construction
extension for the project in 2010. A total of 169 units from the original land use approval had not yet
been completed, and the extension hearing was held before the Hearing Examiner in June of 2010. The
Examiner approved a ten-year extension for the project basing it upon market conditions and eventual
senior housing need. After discussion with the applicant and the City staff, clarification of the decision
was made by then Director Greg Fewins indicating that 200 additional units would be allowed for the
project.
In 2011 a memory care facility replacing up to five of the approved cottages was sought and approved,
resulting in the facility capacity of the approved project to be measured as "beds" as well as "units."
This measure was re-emphasized in a memorandum dated March 28, 2012 from Senior Planner Deb
Barker to Mr. Monte Powell regarding the amount of trips that would be generated by the "beds," and
that the memory care facility is "consistent with the Cottages West senior housing that was approved by
the Hearing Examiner as Phase III of the Village Green Campus, and that the approved Cottages West
site plan could be modified via an administrative process to eliminate duplex units and replace them
with memory care units/beds, consistent with the codes in effect at the time of application."
RJ Development representing continuation of the project has now provided a proposal for the memory
care, multi -bed facility, with 64 beds within 52 units (rooms), all of which are encompassed within a
39,000 square foot building. The proposal increases the number of beds and the square footage of the
building from the decision and interpretations made between 2010 and 2012. The location of the
facility is also placed upon a different area of the property than that proposed in 2010.
Issue: Does the Current Proposal Meet the Intent of the Original Decision and Substantially Conform
to the Hearing Examiner 2010 Decision?
If the current proposal meets the intent of the original decision, then a new Process IV is unnecessary. If
it is determined that the new proposal does not meet the intent of, or is not in conformance with, the
original decision, then a new Process IV is necessary to address the a new proposal.
Findings: Original Intent.and Substantial Conformance
1. Meeting the Intent of the Original Decision.
The paper trail of the decisions shows that the project was approved for senior facility activity. Findings
in the 1998 decision states:
The applicant proposes seven buildings with approximately 32 units in each building, providing
both independent and assisted living accommodations. (emphasis mine)
This statement within the Examiner's findings identifies two significant items that need to be addressed.
First, the approved proposal and site plan showed large buildings, multi -family in nature of design and
similar to the memory care facility being proposed.
Second, the approved proposal indicates an objective of providing "assisted living" care, also a feature
of the proposed memory care facility.
As the project progressed Senior Planner Deb Barker noted in her March 28, 2012 memorandum to Mr.
Monte Powell:
...the memory care use is consistent with the Cottages West senior housing that was approved
by the Hearing Examiner as Phase III of the Village Green Campus, and the approved Cottages
West site plan could be modified via an administrative process to eliminate duplex units and
replace them with memory care units/beds...
Interpretation of Recent Proposal for Memory Care Facility and Conformance with Previous Decisions Page 2
File # 17-102079-00-PC Doc ID 76153
From this information and other texts provided by Hearing Examiners and staff throughout the projects'
completion, it is concluded that the proposed facility meets the intent of the original 1995 and 1998
proposal.
2. Substantial Conformance to Previous Decisions.
The March 28, 2012 memorandum from Ms. Barker states that "(t)he proposal was clarified (in 2011 by
Mr. Fewins and Ms. Barker)as a two story with partial basement building, approximately 29,000 SF in
size." The current proposal is to develop a building 39,000 square feet in size for the facility, or 10,000
more square feet than the 2011 proposal. The current proposal also includes a 30 foot building instead
of the "two story" building as interpreted by Ms. Barker.
The memorandum also states that the facility was proposed and approved for 51 beds which could be
increased up to 60 beds. The current proposal requests approval of a 52 unit/64 bed facility, three more
beds than originally approved.
The increase in the size and square footage of the facility will result in the placement of the facility on an
area where a cottage was originally proposed. The increased area in the larger building, being the
memory care, will replace the amount of building area originally proposed and approved. The scale and
design of the building will have to maintain the appearance of a "two story" building as approved within
the 2010 decision and 2011 interpretation. This will be considered in review of the final design.
The increase in the number of beds as approved through Ms. Barker's memorandum is less than a 7
percent increase over the guideline, and will not be noticed within the final facility. Therefore, the
change is considered insignificant provided the increase in the number of beds is calculated within the
remaining permitted development within the Village Green project as indicated in previous
interpretations and decisions.
In conclusion, the proposed facility is in substantial conformance with the previous Hearing Examiner
decisions and the staff interpretations, provided the design of the building presents a "two story"
appearance in order to be compatible with adjacent environments.
Conclusion:
After review of the 1995 to 2012 Hearing Examiners' decisions and staff interpretations of such
decisions for the Village Green project, it is concluded that the current proposal for the creation of a
39,000 square foot and 64 bed memory care facility proposed in Village Green meets the intent of, and
is in substantial conformance with, the decisions made under Process IV for Village Green, and
therefore, does not require a Process IV public hearing. This interpretation does not influence other
land use, fire, water, building or public facility requirements in the creation of the proposed facility.
Interpretation of Recent Proposal for Memory Care Facility and Conformance with Previous Decisions Page 3
File # 17-102079-00-PC Doc ID 76153
Federal lW.'
Tacoma -
Federal Way
(File #18-101323-00-AD) RE UMT-F E
VILLAGE GREEN MEMORY CARE ivW 213 2010"
PEAK PARKING DEMAND ANALYSW, OF FEDERAL WA'
"COMMUNITY DaIELOPMEN7
May 23, 2018
Q
tll r.
Jake Traffic Engineering, Inc.
Mark J. Jacobs, PE (WA and OR), PTOE, President
2614 391h Ave. SW - Seattle, WA 98116 - 2503
Tel. 206.762.1978 - Cell 206.799.5692
E-mail iake'Lraf•Fi(@COF11cast. i,.et
Ke•l'
sr`
JTE. Jake Traffic Engineering, Inc. .
�r A �.. �
RJ DEVELOPMENT
Attn: Austin Groves, Project Manager
401 Central St SE
Olympia, WA 98501
Re: Village Green Memory Care - Federal Way
File #18-101323-00-AD
Peak Parking Demand Analysis
Dear Mr. Groves,
Mark J. Jacobs, PE, PTOE
President
2614 391h Ave SW - Seattle, WA 98116 - 2503
Tel. 206.762.1978 - Cell 206.799.5692
li-mail jaketraffic@comcast.net
May 23, 2018
I have prepared this Peak Parking Demand Analysis for the Village Green Retirement Campus
located at 35419 1st Ave S, Federal Way, WA 98003. This facility with the addition of the 40
units Memory Care will have a total of 367 units. The break down of the units as I
understand it is as follows:
Independent Living: 165
Assisted Living: 118
Memory Care: 40
C otta des/ D u o l exec: 44
Tota I: 367
The site provides 323 parking stalls.
I have conducted this letter in response to the Technical Review Comment Letter dated April
27, 2018, copy attached. The parking comment is noted below:
I he r r<< loos parkmil IleCuti anal trip ueg--niti011 lirepr;d b% Jr1'-nSpurtafio 1 �Soli.JliOils I11c
i�a'ed ti���enlb�r �fil� . �h��ukl he rc� i5e,1 to relle".I tl1,2 lle; lIk of'the prc?poseii Mena art Care Fa�ilit�
zrnd ; irminl;nits buildin-�. Futlher, the p;rrkW s!Lld% siwuld be re\ tkd to identify staff parkinll Ilcrd�
Arid reflect PM peak h10ff pa -king
A copy of the TSI report was provided to me. This report conducted a Parking Study of the
Phase I facility that comprised of 153 residences including 85 independent units and 52
assisted living units. The parking demand determined by the TSI study is 0.66 stall per unit.
Below is an aerial of the project site obtained from King County IMap. The proposed Memory
Care is located in the southwest area of the campus.
\Vtc_in.\.\-R.�ee. Flaa r01503J \ lagrz Green -Al Da:alopment Fri^relWry\oarFirry^e�or,,,oloi,Go,wy
�...,i. rr> corm on!! r
JTE, Inc.
RJ DEVELOPMENT
Attn: Austin Groves, Project Manager
May 23, 2018
Page -2-
.gyp �:I_' ^"[�,
nl
X :C a r
Memory Care � � y jrs +y f y Af.
r^`� ' �• ; 4MAW
.
+ii +
Parking Demand Review
The followingtable depicts the current plan of the Village Green Retirement Campus
i'
village Green Current Plan
Phase
1
I Independent
L14
suL l
a{:'
iltEenao►x
p
cottages/Uk�Ptexas
16
Total
94
Parking
u
146
ss
a
o
205
III
G
id
40
28
68
I ?.I$''
44
367
32:i
ITE Peak Parking -
The Institute of Transportation Engineers (ITE) Parking Genera ion 4t" Edition identifies
parking rates data for the uses. The rates include the average and 85% peak values. The
following table depicts the parking demand per the ITE data:
I FE Parl5jng Gee eraho( : • 4th E(11'101`1
F'aMing Rate/Unit
'tE . U.-
Use Average 85':>i
Units
Average
CL41 O.s4
JbW
ti
loiai
G�
2$13
223
\Vu_in.\c\-Pro,ac�Fae:�1C_9 Cie y�uage Gieen RJ CeYNOynuit �vJv�a; W.p�Var.iGOLORC,0gY UNI c
JTE, Inc.
RJ DEVELOPMENT
Attn: Austin Groves, Project Manager
May 23, 2018
Page -3-
The ITE data for Assisted Living includes 33 sites, with limited data for Senior Adult Housing.
The Site provided 323 stalls, 0.88 stalls/unit, and the projected 85% parking demand per ITE
data is 223, aka a parking ratio of 0.61 stalls/unit.
The data for Senior Adult Housing/independent Living is somewhat limited. Presuming a one
to one parking rate for Independent/Senior Adult Housing yields a demand of 294 stalls.
Thus a conservative parking demand ratio of 0.80 stall/unit is noted.
Other Parkin Data
JTE, Inc. conducted a Peak Parking Demand Analysis for the Madison House Independent
and Assisted Living facility in Kirkland, the report is dated April 17, 2015. This study was
conducted for a 147 unit retirement facility with 78 parking stalls. At the time of my study
there were 103 units occupied, which is 70%. Of the 103 occupied units, 41 were assisted
living units and 62 were independent living units. The overall parking supply for the study
site is 78 stalls; 0.53 stalls/unit.
The following graphs depict the parking demand in 15 minute intervals based on the data
calibrated to the highest calibration count data.
Tuesday/Wednesday
12:00 PM to 11:59 AM
60
50
40
20
10
1200 1500 1800 2100 0000 0300 0600 0900
Time Period (15 Minute)
\Vla i�_\c\-Cro�eci Filna\'L:B �'s< Village L:een R. Gnrele�ne�i :eae�r�W� /�Par�ingOPmnnUVillOgsU�cen Jcc
f;01 UR CAJi'i liivl Y
RJ DEVELOPMENT
Attn: Austin Groves, Project Manager
May 23, 2018
Page -4-
Wednesdayrrhursday
12:00 PM to 11:59 AM
60
50
w 40
m
U
m 30
I
m
a 20
10
0
1200 1500 1800 2100 0000 0300 0600 0900
JTE, Inc.
Time Period (15 Minute)
The highest observed parking demand is 53 vehicles on Tuesday at 1430. Most hours of the
day it was well below 50. Factoring for occupancy (at 70%) the aforementioned values
indicate the highest demand at 76 stalls with typical demand well below this value.
The parking data collected showed the peak parking demand of the Madison House was
determined at 76 stalls; 0.52 stalls/unit.
Other
The City commented regarding the Community Building and staffing. The Community
Building is for the residents and in itself is not projected to generate any significant parking
demand; albeit some insignificant parking by friends of residents could occur.
I understand that the PM shift change employee count is projected at 20 people.
Transit Service
The map below is the pertinent section of the Metro Transit System Map, March 2018,
depicting transit service in the site vicinity. The site is served by Route The site
appears to be just outside the 903 DART service area. It may behoove the project applicant
to contact Metro regarding the feasibility to have this service include the Village Green
Retirement Campus. Further information on transit service can be found on the Metro
Transit website. (http://transit.metrokc.gov/).
\��L• inc\c\-P+c�ctt ��ks\]019 03•+-Vnlugc Gicen �flJ �r cic�nianl icCerel Wry\�erYingDemxrG+'uxgnON;!oc
l.al nr7 coc'r c;�:� Y
JTE, Inc.
RJ DEVELOPMENT
Attn: Austin Groves, Project Manager
May 23, 2018
Page -5-
Twin Lakes
903
DAR-T
�03
DART
Pa;rfther V K i
Lake _
Para- tit. Francis
Hospit�3i
® : _ Federal
r , . way
Sunrise
_ United q _.
Methodic.t
-- - - _ Church
Summary and Conclusions
Project Site
178 _
This report analyzed the Peak Parking Demand for the Village Green Retirement Campus.
The proposal is to add 40 units of Memory Care space to the campus. I reviewed the Parking
Study conducted for the site in November 2008 that identified a parking demand ratio of
0.66 stall/unit. National data indicates a ratio of 0.61 stall/unit, that I have conservatively
estimated at 0.8 stall/unit. A JTE Inc. study conducted for a facility in Kirkland identified a
parking demand ratio of 0.52 stall/unit.
The Village Green Retirement Campus provides 0.88 stall/unit that exceed the highest
projected values noted in this report. Ample parking is provided by the site to accommodate
occasional parking by friends of residents at the Community Building and staff change
intervals.
I recommend that the City allow the project to proceed with the following recommendation:
- construct the site per applicable City requirements
\V'<_.n�rrvo�oa cn:.,==_e aaa vi�gc u_.� ��_..aocme^� caaeuitvcr\na.�ogo.nana.nesoa�c�nax
RJ DEVELOPMENT
Attn: Austin Groves, Project Manager
May 23, 2018
Page -6-
- contact Metro Transit and inquire regarding the feasibility to get the DART service
area expanded to serve the retirement campus
Please contact me at 206.762.1978 or email me at iaketrafPic@corncast.net if you have any
questions.
MJJ: mjj EXPIRES 4/3l 2 O
Sincerely,
Mark J. Jacobs, PE, PTOE, President
JAKE TRAFFIC ENGINEERING, INC.
os Y. 2-7.2a1.0
\4A Inc\c�-helscl Fl aIVC19 M4-V I'll. Glen Fe Bl Wey\P%k ::.•-+��HVtloge0reen aoe
R COPY OW Y
M7
APPENDIX
CITY OF
L Federal Way
Centered on Qpportunit
April 27, 2018
Austin Groves
It J Development
.101 Central Street SE
Obvilipia, %VA 98-501
(Ills tiwi-i,,YJilc velol-1)loII coo
RE; File 418-101323-00-AD: TECHNICAL REVIEW COALMEN-1 LET"tER
N'iliage {green Memory. Care. "No Site .Address*, Parcel 1"302104-9146, Federal Way
Dear Mr. Grow es:
I'hc City is in receipt of � our March 23, 2018, applicatiOtt for a site plan modification to the Village
Green Phase 11 & Phase 111 Process IV land use approval at the abo+e-mentioned site.
ADDITIONAL. INFORNIAi,iws RFQI ESTI:D
"I -he f"ollowvin` items are based on the initial technical review of the Administrative Decision application.
! . The total number of units has changed from what vvas approved under the process IV_Ilearing
Uxaminer's Decision. The total number of units cannot exceed 367 unit,. The additional unit. for the
\lcmory Care Facility must be deducted from the Phase 11 building dart count. ['lease revise the unit
count on Sheet ADZ accordingly.
_. The previous parking needs and trip generation report, prepared by "tranportatiun Solutions htc-.
dated \ovember �,", 2008, 1,11ould be revised to reflect the needs of the proposed \-leinor} Care Facility
and community buildin!,. Further, the parkirr�l, stud} should be revised to identili staff parking need,
•and reflect P\I peal. hour parking needs.
3. [ ndcr I WCC section 22-640 n0le -5, no f'agade of an% structure ma\ exceed 120 feet in lea_-,th:
howwever, tender note r:3, the City may permit or require modification of dimensional and site design
rq!1iremznts based on the foll0%%1ng criteria
a. .1 he specil7c Itattsrc: of the occupancy and the persons that ++ill he housed ul the proposed
dew elopment.
b. The size of the dwelling units or occupancy rooms or suites and the specific configuration of
and facilities within these units, rooms or suites.
c. I'he impacts on nearby residential uses of the proposed development.
d. The architecture. site design and other design features of the proposed development,
Provide written explanation as to how the building meets modification criteria.
1
NIr (.i't `.':-
:\t�ri!
As Ili�ttd lI} Ellc prL rppllcattion ci7iltirellev letter. the 3��rma1 applicatitvl 111LISt in�kIdt: a mritten
narram r identitvulL h►»% the pr►�iect c► mplies with all applicable �tli,itlines. a'tlet riled in rile F11'RC
C haptur 1►).1 I; (I 1� C"�' chapter "I Article XIX), `CvM►t►tt►tin llE'.ii;�►► C:tricic'litt���.'
5_ Tile :tppr►r►'ed IJMIc ,c:lPe plctlls depict 20 feet ol'Typc 11 landscap ing iiloll., the ;outh propcm line
abuttIM! the sinlzflc fL11110% htnlees rile submitted hindscape plan; do not meet this'landar►l. Nlseti oil
tilt tjiscus•irnt at the nleCting. Ileld till Thursday. April 26. 20 li. ou indicatrtl that rep iced
Iutwscapil'iit pkwt i ouId IllM this requir►nient. please submit the reviser3 laitti:c;tpe p4.lil; t�tr re,ie<<,
Pursuant to F\4 RC 19.1100 (F%VCC' § �?-1510) any landscape modification I'CCIIICSt-S must be
submitted in writing and reviewed as part of Lhe AD approval.
G, Prop ide a description of the Community building and who still be utilizin T the huilditlg.
CLOSING
it
:�3miniitiAite I)CCtilLIS'. appllcntions tn's d44t]ie(l complete at Illy' t3lllt of �ubSlllttill. 1'k►:ls�' pl'l!►lilt
rc\ isad Sitr 14a11 and l:uud, :apiq, plan will, 1 completed project resuhenittaI sheet ie:rlclrsedl. When
suhr;tittinit the reyuv5.e d hillormati►zn. pleast: Provide �►e copies ►sI't3lc revised draft iil�LI at', t a letter
addressing each re\ i.► % ; onuncltt. li an applieant faik to pro. ide additional information to tilt tire.
lath;l;:nit t►� I't� l7C' ICS.t15D. ,�ithill i,SO days of being notified that such inforinati►�n i,; requI . the
.il}I}Ii;;atiem gill be decined fluff ;llld vt�'rtl and t110 tit}' shall have no duty to process, review, or issue anti
tl�ci�ioli> ttith resp4it t0 auzh .i!- Applir"It i011
Iyou have any- questions re,rarding this letter, please feel free to contact me at 253-835-2641 or
I
beckv.chap inia;city offederalway.com,
Sincerely.
1 j a�v
Becky Chapit
Associate Planner
cnc: RCSUbmlttal Farm
Brooks brooks.upowell-homes tom
Hal F)uncanson. haroldd'd Juncansoncu.com
:r;
-f %
;,•§; „ - ; ;
..««Et, l�le £�is Sz' §
§2§�!■� h§(� ||k 2
lnligz-���,�§ K§�e !l&
;!. =e2�5 •_�§® A,!§§g) }(\ (
\\ M) ` e §§|!\§�.�--�;
� � ;�k)!|= lz�2,�«
Je�;_� e ;-_ �■._ !, 2
o■.�.=, E.., .,�, | §§ ■ }
\
}\�\\ }\
; (�.. )i ;; ■� !� . K %(\
\ / , ��; . -§ \
{ (\�§
o =:r ;=wu: 7�>
§ 0 §k(\ $ .�§ �( ! } \ k § i�� : f §§
[§;'§m : ! 'm �} & !�!■� .. ``| �§
§ \}k\ k) ;2| E� f = k ( ,\((§-
|§;G §� 2 �,� E ��z § °` :B \�i ,_
&§!;2§ !\ \\/ �; dk§ƒ k)\§) § . r§|§ § §!§$§ §! )§k)§( #§2
�"SITE -4
Rl
6ONS x0j'O'd
VLecla:4 =10
o-MMA -1
7k NDEJUD 39vv_l)RlL__.
,z >
JO
_. �; 1, .,a
cn
All
4C
r
%F
x �6,; u 9 i
U)
goo;
w Zvi i t
A lz
AS
-M
rrr
V_ 5-f-
kkk
4al
A,
kk
Id
6 k,
LO
M
:0 160g
-Zvi
O j
i.
•z .. _ - r. I �3 LR I
z c
I I I i
I I I I I I
I 1 a x �� I �-i � �3; �'•
41 } •� a` i• I F• N
Li
4 I.
ck:.
rr
j Z k=��--- r I �• �i. � � � f W
.4f o
� 3 33I
E
f
1 f
u I
I
f
i I f
j I
I
i
j° n6r
j ! I
j
i
Sri
r
I
)sf v+
N 4 � � � II 1I j J1i IfI
• �r3 y o3 a € is $ ? G4 ; 1�F7 a!r,� I ! I I I I 1 6 ! f
I". � _ �'� z �•{�f 1 5{• �i�i1 I 4 EE i 4 �� „1' I i J
11 '
O
w
L � N
u{
r'-
w `' I
X V
cr01
F. I
g<J I r _'1 i
�I,
I
6
a
OI
U;
a
• � ss
7S
5
]x1
�
Ao
,
I I
I I
�• s
�$
ff
I
..
>I
9•-
�--•
Yn
I
i
r•
t
,
i
I
I
I
I
I
I
I I�.
0
f
I I I {
I I {
I I -
I O 9 .d O
I I
J
s
I 1• � 1
0
r
I ;
k
� t
] ] I
I 1 ;
I 1 ;
\
kCD
aq CD
° a
] CL
CD
CL
E
r -4 =0
E 0) w
/ CT
<CD CD §
OQ
d \ F
/ D 0
k CD CD
§ � k
0 \ CD
/
§ §
R G CD
CD\ 2
m A
k /_ 2
CD
k C 7
ƒ\�
mCD
En C 3
/M.
\cr
\
\ \
\ \
/ +
/
/ a
\ }
. e
k
=i *
z
a
£
CD
o
C
_
_
%
E
C
=
=
E
CL
5.
_
.0
3
CL
a
a
a
\
\
7
®\
\
3
}
\
\
J
2
J/
\
E
J
-0
J
7
c
M
a=
i
s
-CD
§
M.
\
±�
/M.
6�
0
\�
3
:
m
«
_
m
�
»
c
.,
\
\m
_0
\
)
§§§®0)0)M
w
w
w
7
%
w
w
w)
{
o
p
\
o
P
\
<
§
k�
2
2
p
\
E
>
\
0
§
)
� m
c
e
m
w
r z r
®
!
w�@
_«
o
E
f
w=
c=
7-
0
2
a
CD»
m
a
*
#
*
$
$
rn
%
op,
2
q
m
o
E
o
\
\ \ m
m
m > §
/
..
}
\ § §
®
z m 0
t
w
q§
2
w
a
N)
w
t
P
P
P
5
w
o/
m
w
o.
m
000
0
-P.w
2
\�
ƒ
/
>
r-
/
cr
CD
w
0-:
i
0)
P
w>
a
o
E
e
P=
o±
2
j
a
#
0
`
0
0
0
/\
0
/
Oo
0
0
0
«
o
a
10
w
/
E
I
I
9
P
P
P
\,
3
//
0
0
0
0
6#&
w.
I
§
:0
0
m
Ij�
T
n
C:
fn
N
W
r-
m
m
O
r*
r
c
(.n ul
0
n)
(n
CD
CD
3
o
m
U) D
C
rr
ill c
N
p
a :
3
R 2
r o
C ai
S
ua m
m
CL
D
p
<
(D
3
N
O O
O) �
N
(31
Uq
F' M
— �1
d
CCD
00
ul C
3
ul m
in
C
3
U)
Cn
(Si O
00 W
D
m
N
N
OQ
CD
co
00
W W
00
Ln
N
�
o
W
fin 00
N N
.0. Ln O
m
_
—
w
—
m
m
CD
3
�
n
a
CD
(D
h
C
7
=3
3
O)
M;h.
F�
(n
orn(o
D
N
N
N
9
fi
Ln
Ln
O
00
O
(O
(o
fD
0
0
O
O
O
n
O
P*
07
OQ
(n
v
m
X
(D
N
I�
N
00
O
D)
O
0)
W
N
0
o
O
(.o
4
00
cn
;s
m
W
�.
N
0a
W
SITE PLAN NOTE
THE PURPOSE OF THIS SITE PLAN IS TO IDENTIFY THE REQUESTED
REVISION TO THE UNDERLYING, APPROVED LAND USE SITE PLAN.
REFER TO THE APPROVEDARCHITECTURAL,
CHI ECTURAL CIVIL AND LANDSCAPE
PLANS 08-105555-00-UP. THE AREA OF REQUESTED REVISION IS
ENTIRELY WITHIN THE VILLAGE GREEN PHASE III/COTTAGES WEST
PORTION OF THE CAMPUS AND ARE CLOUDED FOR CONVENIENT
REFERENCE.
SEE SHEET AD2 FOR NUMERICAL SITE DATA SUCH AS BUILDING,
COVERAGE, FLOOR AREA AND PARKING.
SUMMARY OF PROPOSED REVISIONS
1. ONE ADDITIONAL BASEMENT UNIT (UNIT 24) ADDED TO CLUSTER
X. ADDS 1 UNIT AND 2 PARKING SPACES
2. CLUSTER IV REDUCED FROM 4-PLEX TO 2-PLEX AND CHANGED
TO 1 CAR GARAGES. DELETES 2 UNITS AND 6 PARKING SPACES.
3. DELETE CLUSTER V AND CLUSTER XII. DELETES 8 UNITS AND 16
PARKING SPACES.
4. DELETE CLUSTER XIII IN LIEU OF PROPOSED COMMUNITY
BUILDING (APPROVED WITH PREVIOUS LAND USE APPROVALS).
DELETES 3 UNITS.
5. ADD 53,185 SF MEMORY CARE BUILDING. ADDS 40 UNITS. ADDS
28 PARKING SPACES. TWO STREET PARKING SPACES REPLACED
W/2 ADA SURFACE PARKING SPACES.
NET REVISION
28 ADDITIONAL UNITS (ALL MEMORY CARE)
8 ADDITIONAL PARKING
UNITS 1-6 & 9-20
COMPLETE
NE 1/4 SEC 30, TWP 21 N, RGE 4 E, W.M.
VILLAGE GREEN OF FEDERAL WAY
pROP._MED 1ST AVE SOUTH
8' x 16'
STORMFILTER
EXISTING
BIOSWALE
EXISTING VILLAGE GREEN /
COMBINED DETENTION/WET POND / AREA: 3,947 SF
DEPTH: 6 FEET * 0.5 (SLOPED)
ADDITIONAL VOLUME:
11,841 CIF
PROPERTY LIgE
AREA: 6,764 SF
DEPTH: 6 FEET (VERTICAL)
T f
30' 42'
BUILDING PERIMETER
WALKWAYS LINK WITH
SITE RECREATIONAL
TRAIL SYSTEM
20' LANDSCAPE BUFFER, TYP.
4' DEDICATION
4. 0.72L
't 140.54'
=4
I
i
i
I
BLDG F
N
20.9' I
6" FIRE SERVICE
2" WATER SERVICES TYP \
ADDITIONAL VOLUME: w I % 23 STALL 11' DEDICATION
40,584 CIF BUILDING SIDE SEWER U
�, ► NDERGRND
1 CONNECT TO EX MH STUB I PARKING I I
GARAGES I
20% MAX I I
FF=272.5
VILLAGE GREEN PHASE I P1=263.5
`<v
CONNECT STORM f _ TO EX CBS, TYP_,
o EXISTING
FF'
= SIDEWALK, TYP.
EXIST CB TYPE 2 oo & 273.5
RIM = 270.01' °o �� P1=263.5
QQ IE = 261.61' p BLDG G
12" HDPE(E)
T58.�6 STREET LIGHT, TYP 21 STALL&
/ O UNDERGRND
f 0 VILLAGE GREEN PHASE II 8 - 12 PARKING
STORM �� o GARAGE DRAINS, TYP / �7�
.. L 42,
BUILDING PERIMETER / FF=274.5
WALKWAYS LINK WITH o ( P1=264.5
SITE RECREATIONAL
TRAIL SYSTEM S" I BLDG I BLDG H
PROP CB TYPE 2 1 ` BLDG J OPTIONAL v FF=274.5
RIM = 269.00' FF=275.5 UNDERGRND P1=264.5
IE = 263.00 / OPTIONAL
PARKING I I
07 N = 107159.0021 , \ \ GARAGE UNDERGRND I I
E = 1267133.9472, , 76.67' _ 4 PARKING
GARAG
CA 49-
REVISED ACCESS W/2
ADA PARKING
--- I --J
r i 1-7
6 - I 121.27
I 38.01' 47.69'
5 �'� 271.02' 30
----------------- _-- -
1 2 _
--� 1 EX SIDEWALK
.,. .I D AVE
DI OSAL SH
2ND AVE SW i \ i MIN 12'x2O'
I I I \ \ 1 VILLAGE GREEN PHASE III T :.., ~z I 648 SF ADDITIONA
4 i
� COTTAGES WEST BUFFER �Q - �'`�`� ,
III111 EXISTING \\ \\ 9 10 9
I I I I COTTAGES WEST \ \ \\ \ \ / 1 /12 13/14 .,. \ /X
INFILTRATION PONDIi ��\\\\ \ 15/16
40 UNIT MEMORY CARE.
1 I DECK 798 SF W/28 BASEMENT
II
PROJECTION INTO BUFFER
FER
INTERNAL PROPERTY LINE 3 ~-1 w._ -_ �9�� / i 11
1
O / -- - "OTHER" PARKING (LOADING) ALLOWED IN SETBACK
i --
FWRC 19.130.240 (3)
// - ? 11.5 x21.5 247SF SCREENED
I I QQ� EXt� (N RECYCLE/WASTE ENCLOSURE. PRESETT41 WET I j i) I �\ .. SEE ARCH PLAN A1.02
141 SF PROJECTION INTO BUFFER
II 11 II jly//////�' 2� I LAND AVERAGE (9 MIN)
1� VG PHASE III - I LANDSCAPE BUFFER, ITYP.
COTTAGES WEST
ROAD, UTILITY & 1,065 SF ADDITIONAL
AREA OF >40% \\�y�`\�=�i//���j� ��\ GRADING COMPLETE 25 BUFFER
26
STEEP SLOPE�\`
PROPERTY LINE
�`'
J
AREA OF >40%
STEEP SLOPE
SW
0
N
Vn)
DR
S 348th ST
Q
�
^�
SW 2nd ST SITE
Hyleb" State
Park
S� S3rd
c3i�
>
Q
SW 35 th PL N
S 356th ST
V'
V'
V' 99
a
a
a 5
N
001
VICINITY MAP
NOT TO SCALE
CONTACT INFORMATION
APPLICANT/AGENT:
RJ DEVELOPMENT
401 CENTRAL STREET SE
OLYMPIA, WA 98501
CONTACT: AUSTIN GROVES
360-810-8354
ENGINEER/SURVEYOR:
DUNCANSON COMPANY, INC
145 SOUTHWEST 155TH STREET, #102
SEATTLE, WA 98166
CONTACT: HAROLD DUNCANSON
206-244-4141
SHEET INDEX
AD1
ADMINISTRATIVE SITE PLAN
REVISION PLAN
AD2
ADMINISTRATIVE SITE PLAN
REVISION SITE DATA COMPARISO
A-1.0
APPROVED LAND USE SITE
PLAN (MINATOGAWA)
C1
APPROVED LAND USE CIVIL
PLAN
AO.2
MEMORY CARE BASEMENT PLAN
AO.21
MEMORY CARE 1 ST FLOOR
PLAN
AO.22
MEMORY CARE 2ND FLOOR
PLAN
A1.0
OVERALL (PHASE III) SITE PLAN
A1.01
MEMORY CARE SITE PLAN
A3.0
MEMORY CARE ELEVATIONS
A3.01
MEMORY CARE ELEVATIONS
L1.0
LANDSCAPE PLAN
BUFFER AVERAGING CALCULATION
BUFFER AVERAGING ALONG SOUTH LINE OF PHASE III
(COTTAGES AND MEMORY CARE):
PROJECTIONS INTO BUFFER: 939 SF
ADDITIONAL BUFFER: 1,713 SF (MINIMUM)
NET BUFFER INCREASE: 774 SF
GRAPHIC SCALE
0 10 20 40
( IN FEET )
1" = 20' (22x34)
1" = 40' (11X17)
:e
Know what's below.
Call 48 hours before you dig.
R t
DUNCANSON
Company, Inc.
145 SW 155th Street, Suite 102
Seattle, Washington 98166
Phone 206.244.4141
Fax 206.244.4455
00
U_
O�
T
o0)
Q
Q
W
W
00
(7)
S
O�
x
OW
W
W
m
z
Ca
p
00
LL
.J
CD
j
W
www
Fn(---
m
0
mm
o
w
�
cn v
w> U
0
QLd
W
= w
a-
Ir
w
00
a
Lr) Ln
0
z
N r-
z
~
W
W
0)
z
Cn
z
a
�CL
17
a�
W
CL
CD
DRAWN: HMD
DCI NO: 98480.5
DATE: 3/20/18
WAS DUf i
OK� ����
P
29647
AD1
6MITTEO SHEETS
X:\PROJECTS\1998 PROJECTS\98480 VG MEM\98480 VG C3D\VILLAGE GREEN -SHEET C1.DWG MAY 17 2018
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
FROM LAND USE
APPROVAL
BUILDING DATA
INTERNATIONAL BUILDING CODE, 2006 ED. W/
WA STATE ADMENDMENTS. WA STATE
ENERGY, 2006 ED. WA STATE VENTILATION &
INDOOR AIR QUALITY CODES, 2006 ED.
CONSTRUCTION TYPE:
TYPE V-B 1 HOUR
OCCUPANCY TYPE:
LC, LICENSED CARE REQUIRES STATE OF WA
BOARDING HOME LICENSE
FIRE PROTECTION:
SPRINKLERED THROUGHOUT PER NFPA 13-R
SITE
ZONING:
PHASE I & II: RS 7.2
PHASE III: RS 9.6
SIZE, TOTAL:
APPROX. 22 ACRES
PHASE I & 11-EXISTING:
377,467.0 S.F.
PHASE II:
187,780.0 S.F.
PHASE III:
393,157.0 S.F.
TOTAL:
958,404.0 S.F.
LOT COVERAGE:
PHASE I & II -EXISTING: 73,193.0 S.F.
LOT COVERAGE (BLDGS): 19.4%<60%
PHASE II: 58,157.0 S.F.
LOT COVERAGE (BLDGS): 31.1 %<60%
PHASE 111:
LOT COVERAGE (BLDGS):
TOTAL SITE:
LOT COVERAGE (BLDGS)
SETBACKS:
FRONT: 20 FEET
SIDE: 5 FEET
REAR: 5 FEET
FROM SF ZONE: 100 FEET
BLDG H.E-IGHT: _30 FEET AB
68,786.0 S.F.
17.5%,60%
200,136.0 S.F.
20.8% < 60%
A-1.3
BLDG HEIGHT WITHIN 100 FEET OF SINGLE
FAMILY ZONE: 15 FEET PLUS 5 FEET TO AVERAGE
ROOF HEIGHT OF 20 FEET.
NOTE: SEE SITEPLAN, BLDG J AND ELEV. A/2 DOES
NOT EXCEED 20 FEET IN HEIGHT.
MAX BLDG WIDTH WITHIN 100 FEET OF SINGLE
FAMILY ZONE: 50 FEET
MODULATKGN REQUIRED FOR FAC.ADES-OVER 50
FEET
MIN. DEPTH: 3 FEET
MIN. WIDTH: 4 FEET
MAX. WIDTH 35 FEET
NOTE: ALL FACADES ARE MODULATED PER
ABOVE.
MAX. LENGTH OF BUILDING FACADES: 120 FEET
NOTE: REQUESTING MODIFICATION FOR ALL
BUILDING FACADES OVER 120'-0" IN LENGTH.
REQUESTED
REVISION
NE 1/4 SEC 30, TWP 21 N, RGE 4 E, W.M.
VILLAGE GREEN OF FEDERAL WAY
NUMBER OF UNITS
v v v v v v v v PHASE I- EXISTING:
IBC 2015 EDITION & WAC51-11 C WA BUILDING A: 26
STATE ENERGY CODE 2012 BUILDING B: 32
BUILDING C: 20
COTTAGES: 16
MEMORY CARE: V-A
11, CONDITION 2, S2
75,234 SF
19.1 %, <60% MAX ALLOWED
206,584
21.6%, <60% MAX ALLOWED
SUB -TOTAL: 94
PHASE II -EXISTING:
BUILDING D: 30
BUILDING E: 29
SUB -TOTAL: 59
PHASE I1:
BUILDING F:
50
BUILDING G:
32
BUILDING H:
25
BUILDING I:
32
BUILDING J:
35
SUBTOTAL: 174
PHASE III:
SUB -TOTAL: 40
TOTAL NUMBER OF UNITS: 367
FLOOR AREA CALC'S
PHASE I -EXISTING (BLDGS A,B,C):
BASEMENT:
15,060.0 S.F.
1 ST FLOOR:
30,639.0 S.F.
2ND FLOOR:
28,992.0 S.F.
3RD FLOOR:
13,796.0 S.F.
SUB -TOTAL:
88,487.0 S.F.
PHASE I -EXISTING (8 COTTAGES):
SUB -TOTAL: 24,432.0 S.F.
PHASE II -EXISTING (BLDGS D,E):
BASEMENT:
18,300.0 S.F.
1 ST FLOOR:
21,780.0 S.F.
2ND FLOOR:
18,484.0 S.F.
3RD FLOOR:
14,154.0 S.F.
SUB -TOTAL:
72,718.0 S.F.
PHASE 11 (BLDGS F,G,H,I,J):
1 ST FLOOR:
55,808.0 S.F.
2ND FLOOR:
55,479.0 S.F.
3RD FLOOR:
43,379.0 S.F.
SUB -TOTAL:
154,666.0 S.F.
PHASE III (COTTAGE CLUSTERS I-XI11):
SUB -TOTAL: 103,242.0 S.F.
TOTAL FLOOR AREA: 443,545.0 S.F.
BUILDING F:
32
BUILDING G:
27
BUILDING H:
25
BUILDING I:
32
BUILDING J:
30
SUBTOTAL:
146
COTTAGES:
28
MEMORY CARE:
40
SUB -TOTAL:
68
TOTAL NUMBER OF UNITS:
367
PHASE III
COTTAGE
CLUSTERS I -IV, VI -XI:
MEMORY
CARE BASEMENT:
MEMORY
CARE 1ST FLOOR:
MEMORY
CARE 2ND FLOOR:
COMMUNITY
BUILDING:
PHASE III
SUB -TOTAL:
85,895
SF
17,192
SF
18,035
SF
17,958
SF
5,760
SF
144,840
SF
PARKING
PHASE I & II (MULTI -FAMILY):
NUMBER OF UNITS: 315
NUMBER OF EXISTING PARKING STALLS: 103
NUMBER OF NEW STALLS: 120
SUB -TOTAL OF PARKING: 223
PARKING RATIO (UNITS/TOTAL STALLS) 1.4 OR
(.71 STALLS PER UNIT)
PHASE I (SINGLE-FAMILY):
NUMBER OF UNITS: 16
NUMBER OF EXISTING PARKING STALLS: 16
NUMBER OF NEW STALLS: 0
SUB -TOTAL OF PARKING: 16
PARKING RATIO (UNITS/TOTAL STALLS) 1 OR
(1 STALLS PER UNIT)
PHASE III (SINGLE-FAMILY):
NUMBER OF UNITS:
40
NUMBER OF EXISTING PARKING STALLS:
66
NUMBER OF NEW STALLS:
0
SUB -TOTAL OF PARKING:
66
PARKING RATIO (UNITS/TOTAL STALLS)
0.6 OR
(1.5 STALLS PER UNIT)
TOTAL PARKING FOR ENTIRE SITE:
TOTAL NUMBER OF UNITS 367
TOTAL NUMBER OF PARKING STALLS 312
PARKING RATIO (UNITS/TOTAL STALLS) 1.2 OR
(.83 STALLS PER UNIT)
INFORMATION BASED ON NOV. 5, 2008 STUDY BY TSI
(TRANSPORTATION SOLUTIONS INC., REDMOND, WA) FOR
DISCUSSION ON PARKING DEMAND.
SEE SHEET A-1.1 FOR ADDITIONAL PARKING INFORMATION
NUMBER OF SINGLE FAMILY UNITS: 28
NUMBER OF MEMORY CARE UNITS: 40
SUB -TOTAL OF UNITS: 68
PROPOSED TOTAL NUMBER OF STALLS: 42 (COTTAGES)
PROPOSED TOTAL NUMBER OF STALLS: 30 (MEMORY CARE)
STREET PARKING: 12
SUB -TOTAL OF PARKING: 84
PARKING RATIO (UNITS/STALL 0.8 OR
(1.2 STALLS PER UNIT)
TOTAL NUMBER OF UNITS: 367
TOTAL NUMBER OF PARKING STALLS: 323
PARKING RATIO (UNITS/TOTAL STALLS): 1.14 OR
(0.88 STALLS PER UNIT)
Know what's below.
Call 48 hours before you dig.
IDUNCANSONI
Company, Inc.
145 SW 155th Street, Suite 102
Seattle, Washington 98166
Phone 206.244.4141
Fax 206.244.4455
00
U_
O>_
0)
o0)
Q
Q
W
W
00
(3)
3:
C�
Q
x
CW
C)
W
W
a)Z
0C)
Cp
J
�
_I
(1)
>
W
m
v,
VJ
Z�
z
o_
z
0
0
wo
w
o
U
U
LUw
Ir
w
F-
Q
0
0
0
z
z
W
0—
~
_
W
W
(j)z
U)
z
Q
�
�
Q
W
�
Cn
DRAWN: HMD
DCI NO: 98480.5
DATE: 3/20/18
�S DUB
WA
O� o �
AD2
Z
29647
2 OF 2 SHEETS
X:\PROJECTS\1998 PROJECTS\98480 VG MEM\98480 VG C3D\VILLAGE GREEN —SHEET C1.DWG
MAY 21 2018
�MU�� �L W
EX FIRE
HYDRANT
PROPOSED COTTAGE BUILDING
UNDER SEPARATE PERMIT
C>0
\ EX COTTAGE BUILDING
J
SITE BENCHMARK
MAGNAIL IN ASPHALT
t
ELEV = 265.51
i SEE A1.01 AND A1.02 FOR
ACCESSIBILITY DETAILS
EX DEAD END TO BE
RECONFIGURED TO LOOP
0
N
. I
0
C
0
C.
EX 8" SEWER
j�
z
PROPERTY CORNER
N: 107169.29 - "
El; 12671�02.95
�s
0
EX ASPHALT ROAD
W/CURB AND GUTTER
i
SECTION 30, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.
VILLAGE GREEN MEMORY CARE
0
1 J�
I -
N 1—. 0
V TL \
i'
1
PROPOSED COTTAGE BUILDINGS
UNDER SEPARATE PERMITS
EX AUTOMATED GATE
c
b
\' 1
d
GRAPHIC SCALE
20 0 10 20 40
( IN FEET )
1" = 20' (22x34)
1" = 40' (11X17)
EZ7
PROPERTY CORNER
-N: 107031.92
E: 1267099.44
2ND AVE SW
(PUBLIC)
PROPERTY LINE
EX FIRE HYDRANT
TO BE RELOCATED
SITE PLAN REFERENCE
SEE ARCHITECTURAL PLAN A1.0 FOR SITE
PLAN INFORMATION
SITE INFORMATION
PARCEL NUMBER: 302104-9146
SITE LOCATION: 354XX 2ND AVE SW
FEDERAL WAY, WA
JURISDICTION: FEDERAL WAY
SITE AREA: 211,501 SF (4.86 AC)
ZONING: RS9.6
DISTURBED AREA: 41,100 SF (0.94 AC)
NEW/REPLACED PGIS: 6,900 SF
TOTAL NEW/REPLACED IMPERVIOUS: 33,000 SF
CUT: TBD CY
FILL: TBD CY
UTILITY INFORMATION
WATER: LAKEHAVEN UTILITY DISTRICT
SEWER: LAKEHAVEN UTILITY DISTRICT
FIRE: SOUTH KING
SCHOOL: FEDERAL WAY
ELECTRICITY: PUGET SOUND ENERGY
GAS: PUGET SOUND ENERGY
PHONE: CENTURYLINK OR XFINITY
CABLE: COMCAST
SHEET INDEX
C1
CIVIL COVER SHEET
C2
TESC PLAN
C3
TESC DETAILS
C4
GRADING AND DRAINAGE
PLAN
C5
GRADING AND DRAINAGE
ENTRY DETAIL PLAN
C6
GRADING AND DRAINAGE
DETAILS AND NOTES
C7
GRADING AND DRAINAGE
DETAILS
C8
WATER AND SEWER SERVICE PLAN
PERMIT NO. 18-100736-00—CO
RESUBMITTED
APPROVED ,..SAY 15 2018
MY OF FEDERAL WAY
COMMUNFrY DEVELOPMENT
DATE
BENCHMARK IS "HAFF"
3.5" BRASS DISK MK'D "HORIZONTAL
CONTROL DISK - HAFF 1990" SET IN
CONC. MOUND AT NE CORNER OF
PARKING LOT AT THE KING COUNTY
PUBLIC WORKS FACILITY IN RENTON
ELEV.= 337.37 FEET
Know what's below.
Call 48 hours before you dig.
DUNCANSON
Company, Inc.
145 SW 155th Street, Suite 102
Seattle, Washington 98166
Phone 206.244.4141
Fax 206.244.4455
o 0
U)
z
w
0
v,
o
o
~
Z~
�_
z
w p
O
o
r_
VJ
o
�
�
s U
LdLd
W
wLd
a-
Q
0
z
N t-
z
w
W
WW
oc
Q
cf)
('3
U
o:
rw
W
°C
>
0
�o
w
,J
U
DRAWN: HMD
DCI NO: 98480
DATE: 2/12/18
1� DIIN
I
29647
C1
1 OF 8 SHEETS
X:\PROJECTS\1998 PROJECTS\98480 VG MEM\98480 VG C3D\MEM CARE.DWG
GLi
RAI
G Li
RAI
HORIZONTAL JOINT SHINGLE SIDING
WITH THROUGH WALL
FLASHING ELEVTION
5(—)NORTH
Scale: 1/8" = 1'-0"
RAILING
AJ AUJAUEN I WALL I YN.
oA IAI !-I M-=M T/n I
i• �
!ND FLOOR
76'-0"
ST FLOOF_%
64' -
ENTRY PORCH ELEVATION
Scale: 1/8" = 1'-0"
EAST ELEVATION (F
Scale: 1/8" = 1'-0"
IV "VI , LV V V LI \ VnIVII_ IJVLVi\
AS ADJACENT WALL TYP.
SOUTH EAST ELEVATION
Scale: 1/8" = 1'-0"
:o•
ND FLOOR
76'-0"
ST FLOOR /1
64' - 0" V
2)SOUTH ELEVATION PROPERTY LINE
Scale: 1
)00
LOOR
76'-011
EXTERIOR MATERIALS LEGEND
A3.00
V
4-1
iE
i
-�
o
c)
O
_
M
Q 0-)
a0
®J d'
4--0 W
r
Qj pp
� Zco
#;
L0
m CY)
M
Cn
f t 4IM
REGISTERED
�"'
ARC HIT CT
flRENTON G. LAIA$gT}+
STATE QF YYASHINGfON
Z_
U
QJ
O
LL
m CU
ono
U m
u z
V J
U W
Z
Q
w
o_ _
Or- O
W J
W +!
/y
2E W
LLJ
Q
W
Lu
co n
±� V-
O
Q
CL
O
ry
0-
DRAWING ISSUE
NO
REV
DATE
FOR PERMIT ONLY
THIS DOCUMENT HAS BEEN PREPARED FOR
PERMIT APPLICATION AND IS SUBJECT TO REVIEW
ND MODIFICATIONS BY GOVERNMMENT AGENCIE
DRAWING TITLE
EXTERIOR
ELEVATIONS
SCALE:
AS indicated
PLOT DATE:
05/18/17
PRINCIPAL:
BL
PROJ. MGR.:
BL
DRAFTER:
SHEET NO.
A3000
ALIGN PANE
HORIZONT/
WITH THOU
FLASHING
WINDOWS'
ROOF HATCH
/2AQ1 C \/GAIT
V V I 11I V V V V V 1 1 1 .
PROVIDE 6"
Al 11' kl MAAIAI
ROOF
GUTTER
TYP.
ROOF
86' - 0" -171
DOWNSPOUT TYP.
FLOOR
76, - 0"
•�0
.twovmlwq
NORTH EAST ELEVATION
Scale: 1 /8" = 1'-0"
WEST ELEVATION
1 Scale: 1 /8" = 1'-0"
6" CEMENTITIOUS TRIM AT CORNERS,TYP
C3 NORTH WEST ELEVATION
Scale. 1 /8" = 1'-0"
.� ,
76'-FLOOR /1
760"
DoR �1 O11
IVI"_ 11. LVIJVLi\ SAME COLOR
AS ADJACENT WALL TYP.
0
N
ZAL
0
NEL
COATED
0
N
0
(V
_ 2ND FLOOR
76' - 0"
1ST FLOOR
64' - 0"
BASEMENT FLOOR
52'-0"
EXTERIOR MATERIALS LEGEND
CEMENTITIOUS PANEL
A AND 4" CEMENTITIOUS
BATT
B ;I ' CEMENTITIOUS SHAKER
SIDING WITH 6" EXPOSURE
CEMENTITIOUS LAP SIDING
C WITH 6" EXPOSURE
* PTAC GRILLS TO BE PAINTED TO MATCH
ADJACENT EXTERIOR WALL COLOR.
* PROVIDE WINDOW AND STOREFRONT TRIM
PER WINDOW/STOREFRONT DETAIL, SEE A7.21
A3.00
D
V
V
L
-1--+
O
U)
CO
00
Q m
3: CO
W
�
0 CD
n� Z
t t 49e
REGISTERED
ARCN!T CT
S_RENTON C. lAaN$ETH
srar� of wASM�r�Tory
U
Q
QJ
O
ILL00
Z)
m
U
v
u z
2 3:
Q U)
U W
Z
>-- �
W Q
ct� O
O =
L J
�
of <
WJ
�n
V
W
L1
Q
W o
U) In
0 u-
O
Q
CL
O
ry
n
DRAWING ISSUE
NO
REV
DATE
FOR PERMIT ONLY
THIS DOCUMENT HAS BEEN PREPARED FOR
PERMIT APPLICATION AND IS SUBJECT TO REVIEW
ND MODIFICATIONS BY GOVERNMMENTAGENCIE
DRAWING TITLE
EXTERIOR
ELEVATIONS
SCALE:
As indicated
PLOT DATE:
11 /14/17
PRINCIPAL:
BL
PROJ. MGR.:
BL
DRAFTER:
Author
SHEET NO.
A3,01
SITE BENCHMARK
MAGNAIL IN ASPHALT
ELEV = 265.51
EX FIRE SEE A1.01 AND A1.02 FOR
HYDRANT -- ACCESSIBILITY DETAILS
_
EX DEAD END TO BE
RECONFIGURED TO LOOP
\ L
ti ,� —. a
/ N
00
°
gPROPOSED COTTAGE BUILDING
c ' UNDER SEPARATE PERMIT
r
C"�
J,
PROPERTY CORNER
N: 107169.29 `
E: 1267102.95
o
\\
EX ASPHALT ROAD
W/CURB AND GUTTER
EX 8" SEWER
i
\ EX COTTAGE BUILDING
Zz
.I...- vI `_ _.4\.
u
rr-
f f
PROPOSED COTTAGE BUILDINGS \ \ \ t
UNDER SEPARATE PERMITS ��-
SECTION 30, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M.
VILLAGE GREEN MEMORY CARE
EX AUTOMATED GATE
GRAPHIC SCALE
( IN FEET )
1" = 20' (22x34)
1" = 40' (11X17)
"P-ROPERTY CORNER
\N: 107031.92
E: 1267099.44
SITE PLAN REFERENCE
SEE ARCHITECTURAL PLAN A1.0 FOR SITE
PLAN INFORMATION
SITE INFORMATION
PARCEL NUMBER: 302104-9146
SITE LOCATION: 354XX 2ND AVE SW
FEDERAL WAY, WA
2ND AVE SW JURISDICTION: FEDERAL WAY
(PUBLIC) SITE AREA: 211,501 SF (4.86 AC)
ZONING: RS9.6
DISTURBED AREA: 41,100 SF (0.94 AC)
NEW/REPLACED PGIS: 6,900 SF
TOTAL NEW/REPLACED IMPERVIOUS: 33,000 SF
CUT: TBD CY
FILL: TBD CY
UTILITY INFORMATION
EX FIRE HYDRANT
TO BE RELOCATED
WATER: LAKEHAVEN UTILITY DISTRICT
SEWER: LAKEHAVEN UTILITY DISTRICT
FIRE: SOUTH KING
SCHOOL: FEDERAL WAY
ELECTRICITY: PUGET SOUND ENERGY
GAS: PUGET SOUND ENERGY
PHONE: CENTURYLINK OR XFINITY
CABLE: COMCAST
SHEET INDEX
C1
CIVIL COVER SHEET
C2
TESC PLAN
C3
TESC DETAILS
C4
GRADING AND DRAINAGE
PLAN
C5
GRADING AND DRAINAGE
ENTRY DETAIL PLAN
C6
GRADING AND DRAINAGE
DETAILS AND NOTES
C7
GRADING AND DRAINAGE
DETAILS
C8
WATER AND SEWER SERVICE PLAN
PERMIT N0. 18-100736-00—CO
RESUBMITTED
APPROVED MAY 15 2018
CITY 4F FEDERAL, WAY
DATE EN7
BENCHMARK IS "HAFF"
3.5" BRASS DISK MK'D "HORIZONTAL
CONTROL DISK — HAFF 1990" SET IN
CONC. MOUND AT NE CORNER OF
PARKING LOT AT THE KING COUNTY
PUBLIC WORKS FACILITY IN RENTON
ELEV= 337.37 FEET
Know what's below.
C11I 48 hours before you dig.
DUNCANSON
Company, Inc.
145 SW 155th Street, Suite 102
Seattle, Washington 98166
Phone 206.244.4141
Fax 2(J6.244.4455
?
0 r)
m
=�
U)
F-
z
w
z
0
�+ r
VJ
o
F-o
Z
z
w p
O
_
co
o
o
3: U
LdLi
W
Ww
CL a_
tr
Q
0
Z
N
z
W
W
W
Q
C=
('3
U
a:
�-
w
W
�>
�
o�
O
w
�>
J
J
U
DRAWN: HMD
DCI N0: 98480
DATE: 2/12/18
LyQ o DrIA,
C-) � 1
A� 29647
�i1Tn,I,
C1
1 OF 8 SHEETS
X:\PROJECTS\1998 PROJECTS\98480 VG MEM\98480 VG C3D\MEM CARE.DWG
i
G
U
�
�N
oNQ
I
o�O
O
v
wgz
aX:w
�\�
•_
N3Jo
=(j)o
oLjL_
c
e
o--------- —
�
a
-A
J a
k
X
�38
v
a
s.77,■�
-------
-_ _
Y'
I
, 27'± TYPE II LANDSCAPE BUFFER
_ C3
C"i
00
648 SF
E
°
''----- ADDITIONAL
—
BUFFER
`t{t
9' BUFFER
14'-7"'
JG
`.
c2 DECK 798 SF PROJECTION
INTO BUFFER
6' HT WOOD FENCE
O,
I'
1
LAMSCAPE PLAN APPROVAL
- _ Doe.
O
REFER TO L1.1 FOR PLANT LIST
W
L
U
Co
o
00
W
>
^E
0
W
L
`U
U)
z
(D
(3)
it
ca
N
O?
�
C�>mu—
t
v
E
L
Q
O
M
QU)
CIO
0
Q
0
J
O
Q
M
C3
d
W
1
^I
f
V
d)
C
�
t6
N
p
N
L
A
O
.J
>
0
LANDSCAPE MODIFICATIO PLAN 0 15' 30' REsuBMITT9 o
J
Graphic Scale: 1" = 30'-0"
CrrY OF FEDERAL WAY
W TM (0
ou
Wa
5<
W=
Of
LEGEND
O E. 02
N
EXISTING CONIFER & DECIDUOUS TREE >6" d.b.h. Ana A� T ��
�(�\\ 0 OEM
1 � nI VU W2 2
V V - I t-ZZW ZZ�
-J Q Z
FNUQ =NO
TREE TO BE REMOVED �j `�3JN 0�w
N ` .�, Q =X
x
nn -rAr��
Jr-�U VV
0
0
4 TH P L
•
DF17
r<D F 17
OF17 SIZE OF TREE AT DBH
#116 TREE NUMBER TO BE REMOVED
L.
�i
LIMIT OF WORK
a
NOTES
1.
There are 159 trees as part of the Arborist Report, providing 301 tree unit credits. 5 of the trees are
proposed to be removed due being non -viable. The 4.86 acre site requires 121.5 tree unit credits.
The existing trees provide tree unit credits exceeding the minimum requirements.
2.
No clearing shall be allowed on a proposed development site until the tree retention and landscape
plans have been approved by the city of Federal Way.
3.
No disturbance area shall be established for each tree to be protected. The no disturbance zone
shall be equal to the critical root zone which is defined as 12 inches radius for every one inch of tree
diameter measured at four and one-half feet above ground. Any other no disturbance area
proposed by the applicant shall be determined by a qualified arborist and subject to review and
approval by the director.
The no disturbance zone shall be identified during the construction stage with:
(a) A temporary five-foot chain -link fence- and
(b) Tree protection signage attached to the fence which reads "TREE PROTECTION FENCE -
No soil disturbance, parking, storage, dumping, or burning of materials is allowed within the Tree
Protection Fence."
4.
No soil disturbance, parking, storage, dumping, burning of materials, impervious surfaces, fill,
excavation, or storage of construction materials shall be permitted within the no disturbance area.
5.
If the grade level around the tree is to be raised by more than one foot, a rock well shall be
constructed. The inside diameter of the rock well shall be equal to the diameter of the tree trunk
plus 10 feet. Proper drainage, and irrigation if necessary, shall be provided in all rock wells.
6.
The grade level shall not be lowered within the larger of the drip line of the tree(s) or the critical root
zone of the tree(s).
7.
No trenching is allowed in any critical tree root zone areas.
8.
No installation of any impervious surfaces is allowed in critical root zones. Where road or sidewalk
surfaces are needed within critical root zones, unmortared porous pavers or flagstone (rather than
concrete or asphalt) may be used. Boardwalks or bridging may span root zones without harming the
tree roots.
9.
Tree protection areas (i.e., critical root zone) must be prepared to better withstand the stresses of
the construction phase by, if necessary, fertilizing, pruning, and mulching around them well in
advance of beginning any construction activities.
10.
Alternative protection methods may be used if accepted by the director to provide equal or greater
tree protection.
11.
Encroachment into the no disturbance area may be allowed where the director determines
encroachment would not be detrimental to the health of the tree.
TREE PRESERVATION SUMMARY TABLE
Description & Proposed Action
TREE TYPE
VIABLE
NON -VIABLE
TOTAL
Exist. Tree
(>6" d.b.h.)
154
5
159
Retained
Trees
154
0
154
100%
-
Removed
Trees
0
5
5
-
100%
REQUIRED TREE DENSITY
LAND USE
Single Family High Density __
REQ'D TREE UNIT DENSITY
25 tree units / acre
SITE AREA
4.86 acres
TOTAL TREE UNITS REQ'D
121.5 tree units_
TOTAL TREE UNITS RETAINED
301 tree units
Q
U
o
E
0)
N
>
0- 0
c
(D
1-
c�
LL
—
�
®
�0
tU
D'
=
>
In
M
(D
U-
I--
U
IJ
0
n
i
E
Q
O
to
Q.
(n
CY)
Q
v
-
co
J
co
O
Z3M>
C)J
W
>
d'
V
J
z
�
�
�j
M
®
N
z
Q
N
:2
L
A
O)
O
6
a_
a_
Q
! ® _ LJ i i -T v I I v I - , - - NOTES:
F 12 (�r.
�`��� c D 12 D 2 2 DRIPLINE = X
F 1 C` ` -- - I 1 FENCING/ROOT PROTECTION
D F 1 D I 1 D F 2 r 1 2 D F 1 1. PROVIDE CHAIN LINK FENCING AND MAINTAIN 3' OUTSIDE a
- D F 1 D F 1 `4 MAC F 14 D F 1'- D (- 2 OF TREE DRIPLINE.
F 1 TRENCHING AND EXCAVATION
J F D 3 F 1 ZONE A - CRITICAL ROOT ZONE �®
F 12 !D F 15 F 1 - 1. NO DISTURBANCE ALLOWED WITHOUT SITE INSPECTION o
#13 - PACIFIC MADRONE, REMOVE D F 7 F 1 7 I 1 F 1 4 AND APPROVAL OF METHODS TO MINIMIZE ROOT DAMAGE. -
1 F 15 i.
2. SEVERANCE OF ROOTS LARGER THAT 2" IN DIAMETER
REQUIRES APPROVAL FROM COUNTY. 0
DF12 N
#21 - DOUG FIR, REMOVE #65 - DOUG FIR, REMOVE ��' F 1 5 D F 15 F 17 z 3. TUNNELING IS REQUIRED TO INSTALL LINE 3' OR DEEPER
'_- F 1 BELOW GRADE. LM �. EQ. EQ. ZONE B - DRIPLINE G.
#66 - DOUG FIR, REMOVE
F 1 2 1. OPERATION OF HEAVY EQUIPMENT AND/OR STOCKPILING
F 1 D F 2 0 OF MATERIALS IS NOT PERMITTED.
1 F 2 O 2. SURFACE PROTECTION MEASURES REQUIRING s�
#116 - DOUG FIR REMOVE • F12ZONE ADiA.=2x TRENCHING ALLOWED AS FOLLOWS:
A. EXCAVATION BY HAND OR WITH HAND OPERATED
TRENCHER MAY BE REQUIRED.
1 zoNe a DiA. = x B. LIMIT TRENCHING WIDTH. DO NOT DISTURB ZONE A. �
F1 "6zoNE c ( MAINTAIN 2/3 OR MORE OF ZONE B IN UNDISTURBED w
DiA. _ .ex CONDITION. _
3. TUNNELING IS REQUIRED TO INSTALL LINE TOR DEEPER
BELOW GRADE.
0 15' 30' 60' 120'
ZONE C - FEEDER ROOT ZONE N g
1. OPERATION OF HEAVY EQUIPMENT AND/OR STOCKPILING
OF MATERIALS IS NOT PERMITTED. o Z�
Scale: 1" = 30'-0" 2. TRENCHING WITH HEAVY EQUIPMENT ALLOWED AS 6,om
FOLLOWS: N Q w 5 :2
A.MINIMIZE TRENCH WIDTH. RECEIVE 0 0 o U XZ
B. LIMIT TRENCHING WIDTH. DO NOT DISTURB ZONE A. C
/ MAINTAIN 2/3 OR MORE OF ZONE C IN UNDISTURBED v
CONDITION. MAR 2 3 2018 o g
SURFACE PROTECTION MEASURES c
1. 6-8" DEPTH OF WOOD CHIP MULCH. 22OF FEDERRI l.e,;y 17
2. 3/4" THICK PLYWOOD SHEETS OR STEEL PLATES.
IMMUNITY DE VELgFP,i" P M i7 0 0)
am II :3o Q
t� > �
TREE PROTECTION DETAIL
SCALE:NTS UJ UJ
U Q X XO
(n 0 d a-Z
Tree Summary Table
For: Village Green
Tree/
Tag # Species
City of Federal Way
American Forest Management, Inc
Date:
Inspectors:
DBH Tree Height Drip -Line Risk
(inches) Units (feet) (feet) Condition Rating
December 2017
Wilkinson
Comment
1
Douglas fir
12
1.5
75
8
good
low
2
Douglas fir
19
2.5
115
11
good
low
3
Douglas fir
13
2
95
9
fair
low
Forked top
4
Douglas fir
17
2
121
7
good
low
5
Douglas fir
15
2
118
10
good
low
6
Douglas fir
9
1.5
59
4
fair
low
Forked top
7
Douglas fir
26
3
126
12
good
low
8
Douglas fir
11
1.5
90
5
good
low
9
Douglas fir
19
2.5
136
9
good
low
10
Douglas fir
14
2
108
7
good
low
11
Douglas fir
17
2.5
126
7
good
low
12
Douglas fir
7
1
57
6
fair
low
Suppressed
13
Pacific madrone
10
47
poor
moderate
Dead stems, 10% LCR, 108' from house
14
Douglas fir
21
2.5
117
12
good
low
15
Douglas fir
14
2
120
7
good
low
Poor taper
16
Douglas fir
20
2.5
121
13
good
low
17
Douglas fir
23
2.5
125
12
good
low
18
Douglas fir
22
2.5
130
9
good
low
19
Pacific madrone
9
1.5
44
7
fair
low
Some dieback
20
Douglas fir
19
2.5
123
10
good
low
21
Douglas fir
9
65
4
poor
moderate
Suppressed, 10% LCR, 110' from home
22
Douglas fir
18
2
110
5
good
low
23
Douglas fir
15
2
95
7
good
low
Asymmetrical crown
24
Douglas fir
8
1.5
53
5
good
low
Top broke off
25
Douglas fir
14
2
120
10
good
low
26
Douglas fir
9
1.5
85
13
good
low
27
Douglas fir
19
2.5
130
10
good
low
28
Douglas fir
8
1.5
85
5
fair
low
Suppressed
29
Douglas fir
18
2
125
13
good
low
30
Douglas fir
21
2.5
122
15
good
low
31
Douglas fir
19
2.5
130
12
good
low
32
Douglas fir
20
2.5
135
13
good
low
33
Douglas fir
17
2
120
9
good
low
34
Douglas fir
14
2
102
8
fair
low
Forks halfway up
35
Douglas fir
10
1.5
53
6
fair
low
Top broke off
36
Douglas fir
12
1.5
104
4
fair
low
37
Douglas fir
9
1.5
65
9
fair
low
Suppressed
38
Douglas fir
18
2
120
10
good
low
39
Douglas fir
16
2
123
9
good
low
40
Douglas fir
18
2
119
11
good
low
41
Douglas fir
24
3
145
18
good
low
42
Douglas fir
16
2
134
9
good
low
43
Douglas fir
19
2.5
140
12
good
low
44
Douglas fir
8
1.5
92
4
fair
low
Poor taper, narrow crown
45
Douglas fir
15
2
123
13
good
low
46
Douglas fir
18
2
130
8
good
low
47
Douglas fir
27
3
143
17
good
low
48
Douglas fir
15
2
87
8
fair
low
Top broke off
49
Douglas fir
10
1.5
118
5
fair
low
Poor taper, narrow crown
50
Douglas fir
15
2
125
9
good
low
51
Douglas fir
20
2.5
145
13
good
low
52
Douglas fir
18
2
147
4
fair
low
53
Douglas fir
9
1.5
72
6
fair
low
54
Douglas fir
16
2
128
9
good
low
55
Douglas fir
21
2.5
130
10
good
low
56
Douglas fir
24
2.5
135
13
good
low
57
Douglas fir
19
2.5
143
8
good
low
58
Douglas fir
7
1.5
46
5
fair
low
59
Douglas fir
20
2.5
134
11
good
low
Spike knot on lower trunk
60
Douglas fir
22
2.5
140
13
good
low
61
Douglas fir
20
2.5
118
9
good
low
62
Douglas fir
7
1.5
72
5
fair
low
Thin crown
63
Douglas fir
29
3
134
10
good
low
64
Douglas fir
13
2
101
7
fair
low
65
Douglas fir
11
86
10
poor
moderate
Top broke off, 20% LCR
66
Douglas fir
15
81
9
poor
moderate
Top broke off, small LCR
67
Douglas fir
17
2
126
10
good
low
68
Douglas fir
11
1.5
95
4
poor
moderate
Crooked top, very small LCR
69
Douglas fir
10
1.5
74
4
fair
low
Small LCR, suppresssed
70
Douglas fir
18
2
112
9
good
low
71
Douglas fir
16
2
99
7
fair
low
72
Douglas fir
17
2
118
11
fair
low
Thin crown
73
Douglas fir
8
1.5
71
9
fair
low
Asymmetrical crown
74
Douglas fir
21
2.5
134
10
good
low
75
Douglas fir
10
1.5
70
9
fair
low
76
Douglas fir
16
2
120
13
fair
low
77
Pacific madrone
9
1.5
'65
2
fair
low
Very small live crown
78
Douglas fir
19
2.5
126
8
good
low
79
Douglas fir
17
2
120
11
good
low
80
Douglas fir
10
1.5
90
6
fair
low
81
Douglas fir
12
1.5
101
5
fair
low
Asymmetrical crown
82
Douglas fir
30
3
138
17
good
low
Tree Summary Table
For: Village Green
City of Federal Way
American Forest Management, Inc
Date:
Inspectors:
Tree/ DBH Tree Height Drip -Line Risk
Tag # Species (inches) Units (feet) (feet) Condition Rating
December 2017
Wilkinson
Comment
83
Douglas fir
24
2.5
138
12
good
low
84
Douglas fir
19
2.5
118
11
good
low
85
Douglas fir
8
1.5
5
fair
low
Narrow crown
86
Douglas fir
13
2
117
6
good
low
87
Douglas fir
10
1.5
86
7
fair
low
88
Douglas fir
12
1.5
89
9
fair
low
89
Douglas fir
7
1.5
90
6
fair
low
Crooked top
90
Douglas fir
21
2.5
105
19
fair
low
Crooked top, forked trunk
91
Douglas fir
16
2
130
11
good
low
92
Douglas fir
16
2
131
9
good
low
93
Douglas fir
17
2
134
12
good
low
94
Pacific madrone
12,8
2
74
11
fair
low
Small live crown, dead trunks, low risk
95
Douglas fir
9
1.5
66
5
fair
low
Top broke off
96
Douglas fir
18
2
120
9
good
low
97
Douglas fir
18
2
118
12
fair
low
98
Douglas fir
15
2
114
9
1 fair
low
Asymmetrical crown
99
Douglas fir
6
1
70
8
fair
low
100
Douglas fir
12
1.5
113
5
fair
low
Poor taper, trunk bows
101
Douglas fir
10
1.5
108
5
fair
low
Top broke off
102
Douglas fir
13
2
90
7
1 good
low
103
Douglas fir
9
1.5
75
5
fair
low
Thin crown. Suppressed
104
Douglas fir
11
1.5
76
3
fair
low
Narrow crown
105
Douglas fir
9
1.5
80
4
fair
low
Poor taper
106
Douglas fir
10
1.5
83
4
fair
low
Poor taper
107
Douglas fir
19
2.5
108
11
fair
low
Asymmetrical crown
108
Douglas fir
10
1.5
63
1 9
fair
low
Suppressed
109
Douglas fir
11
1.5
100
6
fair
low
110
Douglas fir
14
2
125
8
good
low
111
Douglas fir
16
2
126
10
good
low
112
Douglas fir
20
2.5
132
13
good
low
113
Douglas fir
15
2
130
8
good
low
114
Douglas fir
11
1.5
90
4
fair
low
Thin crown
115
Douglas fir
15
2
88
9
fair
low
Forked top
116
Douglas fir
8
40
7
1 poor
moderate
Top broke off, 10% LCR
117
Douglas fir
7
1.5
65
3
fair
low
118
Douglas fir
9
1.5
71
9
fair
low
119
Douglas fir
7
1.5
70
4
fair
low
120
Douglas fir
10
1.5
69
12
fair
low
Forked top
121
Douglas fir
10
1.5
73
7
fair
Io
122
Douglas fir
14
2
108
9
good
low
123
Douglas fir
9
1.5
79
6
fair
low
124
Douglas fir
16
2
114
9
good
low
125
Douglas fir
11
1.5
86
4
fair
low
126
Douglas fir
18
2
99
6
fair
low
127
Douglas fir
10
1.5
88
5
fair
low
128
Douglas fir
7
1.5
75
3
fair
low
129
Douglas fir
23
2.5
130
10
good
low
130
Douglas fir
23
2.5
141
14
good
low
131
Douglas fir
19
2.5
120
7
good
low
132
Douglas fir
18
2
116
13
good
low
133
Douglas fir
23
2.5
123
14
good
low
134
Douglas fir
20
2.5
147
12
good
low
135
Douglas fir
25
3
150
16
good
low
136
Douglas fir
12
1.5
66
17
fair
low
Top broke off
137
Douglas fir
12
1.5
78
7
fair
low
138
Douglas fir
8
1.5
55
6
fair
low
139
Douglas fir
7
1.5
50
5
fair
low
Thin crown
140
Douglas fir
17
2
99
8
good
low
141
Douglas fir
20
2.5
117
14
fair
low
142
Douglas fir
14
2
100
8
fair
low
Forked top
143
Douglas fir
12
1.5
98
6
fair
low
Thin crown
144
Douglas fir
9
1.5
62
6
fair
low
145
Douglas fir
9
1.5
65
4
fair
low
Thin crown, poor trunk taper
146
Douglas fir
16
2
130
13
good
low
147
Douglas fir
17
2
134
12
good
low
148
Douglas fir
11
1.5
98
5
fair
low
Narrow crown
149
Douglas fir
7
1.5
59
5
fair
low
150
Douglas fir
15
2
117
8
fair
low
Crooked trunk
151
Douglas fir
13
2
96
7
fair
low
Poor taper
152
Douglas fir
13
2
97
6
fair
low
Narrow crown
153
Douglas fir
25
3
127
14
good
low
154
Douglas fir
13
2
101
6
good
low
155
black cottonwood
16
2
142
8
fair
low
156
Douglas fir
18
2
110
9
good
low
157
Douglas fir
13
2
119
10
good
low
158
Douglas fir
16
2 1
130
9
good
low
159
Douglas fir
22
2.5 1
131
10
good
low
Arborist Report Prepared by:
American Forest Management
11415 NE 128th St, Suite 110
Kirkland, WA 98034
425-820-3420
Inspector: Kelly Wilkinson
December 26, 2017
0
8
U
O
N
d
�Zo
o�NQ
}EM O
I
ZZ
-j0
ZZ°0
lCl!
aNVQ \
N3�Na`
2y0
OWfn
O 1
MOM
a
:3,
X
J
W
N
L
(U
V
L
O
E U)
a� >
E Q
a5 0
> LL
®a)O
(6 r-
LO
C�>M
U)
0
.ai
s
0
4-1
V
0 O
W
J z
i ~
CIO
0
� r
J r
(')
CIO
00
O
>Q
C
L
LO
O
N
LO
N
I—
U
D
O
L
E
C
A
�J
V
cu
Jc
O
R
•
r
W
W
V)
M
N
M
M
W
ow
z
C9
U
N m
in
Q
W
5 M
0
0
o
v
WZ
N
0.
L_ Z
00000
-'
WEST PARCEL
REF. L1.2, L2.21 L3.2
F—
G�
cD
M
mi
0 30' 60' 120' 240'
Graphic Scale: 1" = 60'-0"
W L
r
cM LL
ci
.�
cM
O
C�
E
L
�
U)
N
OU
Q.
N
"t
Q
t�
>
O
C
■
Q
LO
>%
�.
E-
O
(ti
p�
()
c)
O
>%
_j
O
T—
m
to
N
O
�
�+
�
as
C. 06
0
a
Q
E�
W
r '
_
iLIJ
o
U)
v' a.
� L
>O
w
w
O
J
J
J
�
Z
LJ
O
�m
cn
Q
w
5 :2
0
O
o
U
xz
W
O
J
am
C
CEIVED
IV 0 8 2018
MFEDERAL �� WAY
ITY DEVELOPMENT
1 ST AVE S 10' MIN. TYPE III
LANDSCAPE BUFFER. PARCEL EAST - LANDSCAPE NOTES & REQUIREMENTS 00
20'+ BUFFER SHOWN Perimeter Landscape (Type III Visual Buffer) 20,600 sf ± Z C44,1
Additional Buffer at SE Corner 2,450 sf d� O�Na _Jo�
Site Interior Landscape 46,174 sf ,�„r <ZWW <wZ
o W
;. �: Total Landscape Area 9,224 sf ± •� Z ��a
t._ w
6 Q
.� , u
t �t
Drought Tolerant Landscape (25% min required) 23,050 sf (33% of total)
1 10' MIN. TYPE III (FWRC 19.125.040[6])
W LANDSCAPE BUFFER.
20' B U
Parking Lot Landscape Area Required. 1,030 sf
FFER SHOWN P g p
Parking Lot Landscape Area Provided: 3,731 sf
., P
(F 0(2)(a))
W RC 19 125 07
r
_ Significant Tree Retention:
�k 1. There are no additional trees units required based upon the Tree Units calculations.
See L2.0 Tree Retention Plans
Other Notes: V
1 J 1. All landscape areas shall have automatic irrigation designed by a landscape architect Q
M f-
1-� j"� t_ Q'r 6' Wlp and installed by a contractor. s,.
�._ J_ L,
ON ROW 2. Bicycle racks shall be located in the underground parking garage O W
Q Op
PLANT SCHEDULE - TYPE III VISUAL BUFFER A� �!/n� �+c�
E VJ v, O
SYM. QTY. TYPE SIZE NOTES M Q
T (�
--- - x Existing Evergreen Tree a-
�Q
Q--x Existing Deciduous Tree N
I --- 26 Evergreen Tree 6'-8' UHT min L >
*, = LL —
\ - - 22 Deciduous Tree 1.75" cal min, 8'-10' HT O O
1 0-56 Large Shrub 24" HT min176 sf J fTS L�O�
-4,000 Groundcovers 1 gallon container, 30" OC Quantity is approximate> co LL
PLANT SCHEDULE - SITE INTERIOR LANDSCAPE
SYM. QTY. TYPE SIZE NOTES
w
o,
Evergreen Tree 12' HT
8 E
I \ --- - -1 Evergreen Tree 10' HT
!84 sf
^� ^� 8 Evergreen Tree 6' HT
11 Deciduous Tree 1.75" cal, 8'-10' HT �U),,
t o - -9 Deciduous Tree 2" cal, 10'-14' HT
M
Deciduous Tree 1.75 cal ^
135 Large Shrub 24" HT min i
J Q O
{
a --211 Medium Shrub 18" HT min N
O
236 s U
-681 Small or Columnar Shrub 12" HT min rL Qj J
MECH.'
2,100 Groundcovers 1 gallon container, 30" OC Quantity is approximate V
O
0 Y pP N a Q `M O`
187sf Ft 0 --- Lawn Areas s .ed or sod 21,500 SF ± 'a U O J
t6 O C
/ O (6
TREE, SHRUB & GROUNDCOVERS PI ANTING OPTIONS - native & native adapted O N
s LO
Trees - Evergreen U c� O
%� ��_ • LO
Grand Fir, Douglas Fir, Western Red Cedar, Sitka Spruce, Western White Pine, Shore Pine, Incense .J O
Cedar Dawn Redwood N 2:
•.. ts7
Tre
es Deciduous v• ✓
Sf
• Vine maple. Big leaf maple, Serviceberry, sChoke err Hawthorn Oregon Ash, ChkCherry, Norway le
-- - _ Y Y maple,
609sf - -> European Hornbeam, Sweet Gum, Honey Locust, Dogwood, Oak
M
q
C/ Shrubs
' W = • Dogwood, Viburnum, Azalea, Rhododendron, Laurel, Spirea, Evergreen Huckleberry, Sweetbox,
Ocean Spray, Hydrangea, Holly, Oregon Grape, Barberry, Potentilla Lilac Daphne, Stewartia
i P Y P Y
308��.W --' Honeysuckle, Clematis, Rock Rose, Glossy Abelia, Pacific Wax Myrtle, Strawberry bush, etc
A .
Groundcovers
• Oregon Grape, Cotoneaster, Gro-low Fragrant Sumac, Vinca, Coastal Strawberry, Kinnikinnick, Q
Spurge, Carpet Bugle
196sf i GENERAL LANDSCAPE NOTES W
1. Perimeter Landscaping - Ten (10) feet of 'Type III' landscaping must be provided along the W
south perimeter property line to minimize impacts on residences to the south, unless
approved. Existing significant trees are required to be retained or replaced
41
O
otherwise
TYPE III
within the applicable landscape buffer per the design guidelines. Existing significant trees Rf �,
10MIN
:. . must be depicted on the site plan o
r
t LANDSCAPE BUFFER.
2. Interior Parkin Lot Landscaping'T e IV' landsca in in a total amount of 22 square >
- q
20' B U FFER SHOWN g YP P g � � w
feet per parking stall must be incorporated into parking lots.CIL
l 3. Specific trees, shrubs, groundcovers and street tree selections will be made at the time of
C)
the permit / construction drawings, including names, species, quantities, sizes and notes. N
' 4. Specific parking lot planter island quantities will be verified at the time of permit
/ MECH ! g P P P q p
construction drawings. -- �
146 sf ,
-TI
/ I - w
G � �
260 sf 130 sf'. 118 sf
' TALL EARTH BERM
3 CONCRETE WALL 3 _ O
TO SCREEN PARKING TO SCREEN PARKING
„
FROM ROAD FROM ROAD s�
L1
w
-� —.—_ - - = - _-•-jam ..�. ',,,,,,A",,, , , �w..v> ' -:vim �+ C.9 Z U (n 00
o W
196 sf 200 sf S
W W 2 W D
6�
„, of _ _ _�
- o
rr.
gl�
6' WIDE ON ROW LANDSCIAPE BUFFER. 2N D AVE SW r Co
E Ill
I L
20 BUFFER SHOWN
J
0 15 3060 120' r' Z >
Graphic Scale: 1" = 30'-0" w w W
a o o.
U Q X ofC
fn 0 2.a�
Trees - Evergreen
• Grand Fir, Douglas Fir, Western Red Cedar, Sitka Spruce, Western White Pine, Shore Pine, Incense
Cedar, Dawn Redwood
Trees - Deciduous
• Vine maple, Big leaf maple, Serviceberry, Hawthorn, Oregon Ash, Choke Cherry, Norway maple,
European Hornbeam, Sweet Gum, Honey Locust, Dogwood, Oak
Shrubs
• Dogwood, Viburnum, Azalea, RhRdodendron, Laurel, Spirea, Evergreen Huckleberry, Sweetbox,
Ocean Spray, Hydrangea, Holy, Oregon Grape, Barberry, Potentilla, Lilac, Daphne, Stewartia,
Honeysuckle, Clematis, Ro Rose, Glossy Abelia; Pacific Wax Myrtle, Strawberry bush, etc
Groundcovers
• Oregon Grape, Cotoneaster, Gro-low Fragrant Sumac, Vinca, Coastal Strawberry, Kinnikinnick,
Spurge, Carpet Bugle
GENERAL LANDSCAPE NOTES
1. Perimeter Landscaping - Ten (10) feet of 'Type I II' landscaping must be provided along the
south perimeter property line to minimize impacts on residences to the south, unless
otherwise approved. Existing significant trees are required to be retained or replaced
within the applicable landscape buffer per the design guidelines. Existing significant trees
must be depicted on the site plan.
2. Interior Parking Lot Landscaping -'Type IV' landscaping in a total amount of 22 square
feet per parking stall must be incorporated into parking lots.
3. Specific trees, shrubs, groundcovers and street tree selections will be made at the time of
the permit / construction drawings, including names, species, quantities, sizes and notes.
4. Specific parking lot planter island quantities will be verified at the time of permit /
construction drawings.
L
Q
OLZ
U)
N
O
U
Q,
aj
't
O
Q
C
N
4=
Q
>
In
O
>%
_I
.J
0
�O�
O
M
>+O
M
LO
O
—�
V-
N
�!
0
a
N N
W
CL
E
V
(N
Z
^+ O
L W
CY)W /V
N
H
Ld
Ld
2
U)
O
J
J
J
0
Z
0W
<
N
W
S�
O
p
U
irZ
N
0 15' 30' 60' 120' r
J
Graphic Scale: 1" = 30'-0"
I
O
u
x
W
J
a
n
00
STRONG STOUT STEMS AND BUDS
WIDE BRANCH
ATTACHMENT
REMOVE BURLAP FROM 1 �1 U
TOP HALF OF ROOTBALL COVER SOIL LOOSENED AREA WITH 2"
BARK MULCH. KEEP MULCH 3" FROM
TREE TRUNK
SCALE: NTS
PLACE TOP OF
ROOTBALL 1" ABOVE
LEVEL GROWING IN
NURSERY
DIG THE PLANTING
PIT AT LEAST
TWICE THE SIZE
OF THE ROOTBALL
TILL COMPACTED
SUBGRADE AS
SPECIFIED
REMOVE BURLAP
FROM TOP %2 OF
ROOTBALL
NOTES:
1. FERTILIZE & WATER AS
SPECIFIED FOLLOWING
PLANTING.
2. SEE SPECS FOR ADDITIONAL
INFORMATION
3. SEE STAKING DETAILS.
COVER SOIL
LOOSENED AREA
WITH 2" MULCH. KEEP
II MULCH 3" AWAY FROM
TREE TRUNK
wj.m..
II I II I I I II I II I II II I II I II I II I� I'- I SOIL BACKFILL
(SEE SPECS)
CONIFER PLANTING DETAIL
SCALE: NTS
PLACE ROOTBALL ON
SOLID SOIL
-\ r- 2" MULCH
GROUNDCOVER PLANTING DETAIL
SCALE: NTS
W
U
z
9
00
O
00
O
DECIDUOUS TREE STAKING DETAIL_
SCALE: NTS
CONIFER TREE STAKING
SCALE: NTS
,K TREE TIES
2" MULCH
SAUCER
.E STAKE. PLACE
3ALL z
00
12"
MIN
TOPSOIL BACKFILL
(SEE SPECS)
TRATE 12" MIN. BELOW REMOVE BURLAP FROM TOP
�NTING PIT %2 OF ROOT BALL
CHAIN LOCK TREE TIE
0 LODGE POLE STAKE.
_ACE OUTSIDE ROOTBALL
SHRUB PLANTING DETAIL
SCALE: NTS
NOTES:
1. USE PLANT STARTER SOLUTION
DURING PLANTING OPERATION.
FEED AS SPECIFIED.
2. SHRUBS SHALL BEAR SAME
RELATION TO FINISHED GRADE AS
IT BORE TO PREVIOUS EXISTING
GRADE. TOP OF ROOTBALL SHALL
BE 1" ABOVE FINISHED GRADE
FG
J
z_
co
co
SPREAD ROOTS OF BASE
ROOT PLANTS OUT OVER
CONE OF HAND -FIRMED
TOPSOIL
CONE OF HAND -FIRMED
TOPSOIL FOR BALL &
BURLAP PLANTS
CANVAS WEB Of
RUBBER TRTIE
W
a 2'
MIN
—1/2" x 8'-0' REBAR
o _0>•
TREE STAKE (2 TYP)
MiN.
amp
4" PERF. PIPE, FILLED
WITH DRAIN ROCK
FINISH GRADE
WOOD CHIP MULCH
i
cv
__ SIDEWALK
ROOT BARRIER
(TYP., BOTH SIDES)
nu{ i f
BACKFILL WITH CLEAN`
NATIVE SOIL 1'-6" MIN.
REMOVE BURLAP FROM NOT TO SCALE
NOTES: TOP 1�3 OF ROOT BALL
PLANTING:
ADD 3 WATERING RING MIN, 2X ROOT BALL ------FIRM 41 NATIVE SOIL
1. Dig hole 2-3 times the width of the root ball and as deep as the root ball. Do not
make hole deeper than root ball.
2. Remove containers, biodegradable pots, synthetic or treated burlap, wire, twine, or
ropes. Leave natural burlap in place and fold back. Loosen the roots and spread or cut
circling roots.
3. Place top of root ball even with or slightly higher than soil grade on firm soil. Do
not add soil amendments or gravel unless approved by Public Works Director.
4. Install 4% 24" perforated drain pipe; fill with drain rock. Pipe shall not extend more
than 1 /2" above finish grade.
5. Back fill with clean native soil. Firm soil around the root ball; water slowly and
thoroughly.
6. Mulch around tree with 2-4" wood —chip mulch. Do not place mulch next to trunk.
ROOT BARRIER:
1. Root barrier shall be rigid High Impact Polypropylene treated with UV inhibitors,
minimum 18" height, with 1 /2" raised vertical ribs 6" on center, or approved equal.
2. Install root barrier in continuous 24' strip, centered on tree, next to sidewalk and
curb according to manufacturer's directions. Exposed edge shall not extend more than
1/2" above finished grade.
STAKING:
1. Use 2, 1-1/2" by 8'-0" rebar tree stakes. Do not drive stake through root ball.
2. Attach tree to stake with canvas web belting or rubber, using a figure-8 formation.
TAGS:
1. Remove tags after inspection.
JULY 2014
A ■ M
PUBLIC STREET TREE Federal WaywoRKS
,STREET TREE PLANTING IN PLANTER STRIP DETAIL
SCALE: NTS
E
co
V
O
L.
a
U
p
`} N
Z =
OOW�•:.
O�M
J �
01G"E'l
ZZQ
QUd
ZZ00
WOU0ZN
pU
LLI
J
J d
X
W
co
O
O
Q. 00
E VJ 0)U��
Q
Co
L
>()U_
f--
W
D
0
N
t�
CO
_
�
N
C�
E
L
Q
�
N
OU
CL
N
O
00
J
Rf
M
>
(3)
(0
Q
Ll
O
>>1
J
>
J
Q-
E
O
O
r-
�
(y)
07
�+
Jr-I—N2t
O
(u
Lo
O
•—
Q
0
i
i
to
0
z
(L
0
V)
LJ
w
0-1
CL
M
V
i
J
w
w
CD
J
J
J
Z
o
aW
U5
<
w
5�
O
0
0
U
ofz
i
REQUIRED TREE DENSITY
LAND USE Single Family High Density
REQ'D TREE UNIT DENSITY 25 tree units / acre
SITE AREA 4.31 acres
TOTAL TREE UNITS REQ'D 108 tree units (4.31 x 25)
EXIST. TREE UNITS TO REMAIN 124 tree units
REPLACEMENT TREE UNITS 0 required
GENERAL TREE RETENTION NOTES
1. No clearing shall be allowed on a proposed development site until the tree retention and landscape plans have
been approved by the city of Federal Way.
2. A disturbance area shall be established for each tree to be protected. The no disturbance zone shall be equal
to the critical root zone which is defined as 12 inches radius for every one inch of tree diameter measured at
four and one-half feet above ground. Any other no disturbance area proposed by the applicant shall be
determined by a qualified arborist and subject to review and approval by the director.
The no disturbance zone shall be identified during the construction stage with. -
(a) A temporary five-foot chain -link fence; and
(b) Tree protection signage attached to the fence which reads "TREE PROTECTION FENCE — No soil
disturbance, parking, storage, dumping, or burning of materials is allowed within the Tree Protection
Fence."
3. No soil disturbance, parking, storage, dumping, burning of materials, impervious surfaces, fill, excavation, or
storage of construction materials shall be permitted within the no disturbance area.
4. If the grade level around the tree is to be raised by more than one foot, a rock well shall be constructed. The
inside diameter of the rock well shall be equal to the diameter of the tree trunk plus 10 feet. Proper drainage,
and irrigation if necessary, shall be provided in all rock wells.
5. The grade level shall not be lowered within the larger of the drip line of the tree(s) or the critical root zone of
the tree(s).
6. No trenching is allowed in any critical tree root zone areas.
7. No installation of any impervious surfaces is allowed in critical root zones. Where road or sidewalk surfaces
are needed within critical root zones, unmortared porous pavers or flagstone (rather than concrete or asphalt)
may be used. Boardwalks or bridging may span root zones without harming the tree roots.
8. Tree protection areas (i.e., critical root zone) must be prepared to better withstand the stresses of the
construction phase by, if necessary, fertilizing, pruning, and mulching around them well in advance of
beginning any construction activities.
9. Alternative protection methods may be used if accepted by the director to provide equal or greater tree
protection.
10. Encroachment into the no disturbance area may be allowed where the director determines encroachment
would not be detrimental to the health of the tree.
DRIPLINE = X
NOTES:
FENCING/ROOT PROTECTION
1. PROVIDE CHAIN LINK FENCING AND MAINTAIN 3' OUTSIDE
OF TREE DRIPLINE.
TRENCHING AND EXCAVATION
ZONE A - CRITICAL ROOT ZONE
1. NO DISTURBANCE ALLOWED WITHOUT SITE INSPECTION
AND APPROVAL OF METHODS TO MINIMIZE ROOT DAMAGE.
2. SEVERANCE OF ROOTS LARGER THAT 2" IN DIAMETER
REQUIRES APPROVAL FROM COUNTY.
3. TUNNELING IS REQUIRED TO INSTALL LINE 3' OR DEEPER
BELOW GRADE.
ZONE B - DRIPLINE
1. OPERATION OF HEAVY EQUIPMENT AND/OR STOCKPILING
OF MATERIALS IS NOT PERMITTED.
2. SURFACE PROTECTION MEASURES REQUIRING
TRENCHING ALLOWED AS FOLLOWS:
A.EXCAVATION BY HAND OR WITH HAND OPERATED
TRENCHER MAY BE REQUIRED.
B. LIMIT TRENCHING WIDTH. DO NOT DISTURB ZONE A.
MAINTAIN 2/3 OR MORE OF ZONE B IN UNDISTURBED
CONDITION.
3. TUNNELING IS REQUIRED TO INSTALL LINE 3' OR DEEPER
BELOW GRADE.
ZONE C - FEEDER ROOT ZONE
1. OPERATION OF HEAVY EQUIPMENT AND/OR STOCKPILING
OF MATERIALS IS NOT PERMITTED.
2. TRENCHING WITH HEAVY EQUIPMENT ALLOWED AS
FOLLOWS:
A. MINIMIZE TRENCH WIDTH.
B. LIMIT TRENCHING WIDTH. DO NOT DISTURB ZONE A.
MAINTAIN 2/3 OR MORE OF ZONE C IN UNDISTURBED
CONDITION.
SURFACE PROTECTION MEASURES
1. 6-8" DEPTH OF WOOD CHIP MULCH.
2.3/4" THICK PLYWOOD SHEETS OR STEEL PLATES.
C
Ic
►
Cn
o
co
S
r tL
01
F.
CnQ
> o a
N �
o
N
.N
I
C
rho �
o
Ili
o
o
N N
00
a
E „
CI
LL
E V
(w)
N Q
N � t>�
0)� O
(U 1 -0
> ey) LL
0)
a-+
U
=
O
N
U
L
Q
U
N
O
r-
vt
Q
Rf
>
O
�
U)Q
Q
>
L0
O
�
J
J
0-
E
O
N
C
r--
o
M
>%
J
O
T-
(0
I-
�
CV
O
22
W
6
a
CL
E
va
_ C
L �
Z
o
LIJ
W
w
w
LL
O
c
C
r
I
C
U
a
`C
c
a�
Fsxp
52 - Deciduous Trees (small, medium, large canopy species, <450 sf - >1250sf)
3 - Evergreen Trees (small, medium, large canopy species, <450 sf - >1250sf)
356 TOTAL TREE UNITS proposed at completion of project (excluding Landscape Buffer)
0 - Additional Tree Units required
REQUIRED TREE DENSITY
LAND USE
Single Family High Density
REQ'D TREE UNIT DENSITY
25 tree units /_ acre
SITE AREA
4.86L acres
TOTAL TREE UNITS REQ'D
121.5 tree units (4.86 x 25)
EXIST. TREE UNITS TO REMAIN
301 tree units
REPLACEMENT TREE UNITS
0 required
GENERAL TREE RETENTION NOTES
1. No clearing shall be allowed on a proposed development site until the tree retention and
landscape plans have been approved by the city of Federal Way.
2. A disturbance area shall be established for each tree to be protected. The no disturbance zone
shall be equal to the critical root zone which is defined as 12 inches radius for every one inch of
tree diameter measured at four and one-half feet above ground. Any other no disturbance area
proposed by the applicant shall be determined by a qualified arborist and subject to review and
approval by the director.
The no disturbance zone shall be identified during the construction stage with:
(a) A temporary five-foot chain -link fence; and
(b) Tree protection signage attached to the fence which reads "TREE PROTECTION FENCE —
No soil disturbance, parking, storage, dumping, or burning of materials is allowed within the
Tree Protection Fence."
3. No soil disturbance, parking, storage, dumping, burning of materials, impervious surfaces, fill,
excavation, or storage of construction materials shall be permitted within the no disturbance area.
4. If the grade level around the tree is to be raised by more than one foot, a rock well shall be
constructed. The inside diameter of the rock well shall be equal to the diameter of the tree trunk
plus 10 feet. Proper drainage, and irrigation if necessary, shall be provided in all rock wells.
5. The grade level shall not be lowered within the larger of the drip line of the tree(s) or the critical
root zone of the tree(s).
6. No trenching is allowed in any critical tree root zone areas.
7. No installation of any impervious surfaces is allowed in critical root zones. Where road or sidewalk
surfaces are needed within critical root zones, unmortared porous pavers or flagstone (rather than
concrete or asphalt) may be used. Boardwalks or bridging may span root zones without harming
the tree roots.
8. Tree protection areas (i.e., critical root zone) must be prepared to better withstand the stresses of
the construction phase by, if necessary, fertilizing, pruning, and mulching around them well in
advance of beginning any construction activities.
9. Alternative protection methods may be used if accepted by the director to provide equal or greater
tree protection.
10. Encroachment into the no disturbance area may be allowed where the director determines
encroachment would not be detrimental to the health of the tree.
DRIPLINE = X
NOTES:
FENCING/ROOT PROTECTION
1. PROVIDE CHAIN LINK FENCING AND MAINTAIN T OUTSIDE
OF TREE DRIPLINE.
TRENCHING AND EXCAVATION
ZONE A - CRITICAL ROOT ZONE
1. NO DISTURBANCE ALLOWED WITHOUT SITE INSPECTION
AND APPROVAL OF METHODS TO MINIMIZE ROOT DAMAGE.
2. SEVERANCE OF ROOTS LARGER THAT 2" IN DIAMETER
REQUIRES APPROVAL FROM COUNTY.
3. TUNNELING IS REQUIRED TO INSTALL LINE TOR DEEPER
BELOW GRADE.
ZONE 8 - DRIPLINE
1. OPERATION OF HEAVY EQUIPMENT AND/OR STOCKPILING
OF MATERIALS IS NOT PERMITTED.
2. SURFACE PROTECTION MEASURES REQUIRING
TRENCHING ALLOWED AS FOLLOWS:
A. EXCAVATION BY HAND OR WITH HAND OPERATED
TRENCHER MAY BE REQUIRED.
B. LIMIT TRENCHING WIDTH. DO NOT DISTURB ZONE A.
MAINTAIN 2/3 OR MORE OF ZONE B IN UNDISTURBED
CONDITION.
3. TUNNELING IS REQUIRED TO INSTALL LINE TOR DEEPER
BELOW GRADE.
ZONE C - FEEDER ROOT ZONE
1. OPERATION OF HEAVY EQUIPMENT AND/OR STOCKPILING
OF MATERIALS IS NOT PERMITTED,
2. TRENCHING WITH HEAVY EQUIPMENT ALLOWED AS
FOLLOWS:
A.MINIMIZE TRENCH WIDTH.
B. LIMIT TRENCHING WIDTH. DO NOT DISTURB ZONE A.
MAINTAIN 2/3 OR MORE OF ZONE C IN UNDISTURBED
CONDITION.
SURFACE PROTECTION MEASURES
1. 6-8" DEPTH OF WOOD CHIP MULCH.
2.3/4" THICK PLYWOOD SHEETS OR STEEL PLATES.
C'0
N O
� O
Q. CO
E u) O
M Q
Q >1
Co
O� N
•� l� O
>cy)LL
L -1
O
CL
v
._
CO
■�
N
C)
a�N
E
UO
0
00
Q
!Cf
>
0)�
N
U
Q
>
LO
O
>1
J
4-
J
O
O
T-
O
i+
Jr-
O
-I—
M
�
N�
O
0
4-0
ate.
E
va
Q
_
i
z
o
5
�
L
\�
r
w
w
V)
O
_J
_J
_J
w
0
0 15' 30' 60' 120' TREE PROTECTION DETAIL
SCALE:NTS
Graphic Scale: 1" = 30'41 N
N
J,
i
0
w
Y
< W
0 U
a
N
oL,
w
U5 m
5:2
w:D
Of Z
i cV
y
O
CV
E
N
>
a
—
<
O
Z
>
J
W
W
F-
00
<
a
Xo
0
a-
a z
a
1ST AVE S
IRRIGATION HEAD SCHEDULE
SYM.
CATALOG NUMBER
COLOR
RADIUS
GPM
PSI
HUNTER MP ROTATOR HEADS
PROS-06-PRS40-CV-R-
(ALL SPRAY BODIES)
o
PRS40-CV-R-MP-CORNER
TURQUOISE
8
0.12
40
PRS40-CV-R-MP1000-900
MAROON
8
0.15
40
o
PRS40-CV-R-MP1000-900
MAROON
8
0.23
40
o
PRS40-CV-R-MP1000-900
MAROON
8
0.30
40
p
PRS40-CV-R-MP1000-2100
LIGHT BLUE
8
0.37
40
9
PRS40-CV-R-MP1000-2100
LIGHT BLUE
8
0.45
40
p
PRS40-CV-R-MP1000-360°
OLIVE
8
0.60
40
A
PRS40-CV-R-MP-CORNER
TURQUOISE
10
0.13
40
0
PRS40-CV-R-MP1000-900
MAROON
10
0.16
40
m
PRS40-CV-R-MP1000-900
MAROON
10
0.25
40
m
PRS40-CV-R-MP1000-900
MAROON
10
0.31
40
p
PRS40-CV-R-MP1000-2100
LIGHT BLUE
10
0.38
40
PRS40-CV-R-MP1000-2100
LIGHT BLUE
10
0.47
40
PRS40-CV-R-MP1000-3600
OLIVE
10
0.63
40
v
PRS40-CV-R-MP-CORNER
TURQUOISE
12
0.15
40
PRS40-CV-R-MP1000-900
MAROON
12
0.16
40
v
PRS40-CV-R-MP1000-900
MAROON
12
0.25
40
v
PRS40-CV-R-MP1000-900
MAROON
12
0.32
40
PRS40-CV-R-MP1000-2100
LIGHT BLUE
12
0.41
40
9
PRS40-CV-R-MP1000-2100
LIGHT BLUE
12
0.48
40
PRS40-CV-R-MP1000-360°
OLIVE
12
0.65
40
A
PRS40-CV-R-MP-CORNER
TURQUOISE
15
0.19
40
PRS40-CV-R-MP1000-900
MAROON
15
0.21
40
PRS40-CV-R-MP1000-900
MAROON
15
0.30
40
PRS40-CV-R-MP1000-900
MAROON
15
0.37
40
PRS40-CV-R-MP1000-2100
LIGHT BLUE
15
0.43
40
PRS40-CV-R-MP1000-2100
LIGHT BLUE
15
0.57
40
PRS40-CV-R-MP1000-3600
OLIVE
15
0.75
40
m
PRS40-CV-R-MPLS515
IVORY
5X15
0.22
40
m
PRS40-CV-R-MPRS515
COPPER
5X15
0.22
40
CTD--3
PRS40-CV-R-MPSS530
BROWN
5X30
0.22
40
HUNTER BUBBLER NOZZLES
NOZZLE
RADIUS
GPM
PSI
+
PRS40-CV-R-MSBN-20F
NA
3
2.0
40
PRS40-CV-R-MSBN-10H
NA
3
1.0
40
a
PRS40-CV-R-MSBN-50Q
NA
3
0.5
40
HUNTER MP ROTATOR
HEADS
NOZZLE
RADIUS
GPM
PSI
Q
1-20-06-SS-R
2.0 GREY
25
1.6
30
9
1-20-06-SS-R
2.0 GREY
25
1.6
30
0
1-20-06-SS-R
2.0 GREY
25
1.6
30
p
1-20-06-SS-R
2.0 GREY
25
1.6
30
Q
1-20-06-SS-R
6.0 BLUE
40
5.6
35
1-20-06-SS-R
6.0 BLUE
40
5.6
35
1-20-06-SS-R
6.0 BLUE
40
5.6
35
1-20-06-SS-R
6.0 BLUE
40
5.6
35
NOZZLES
FOR ROTORS ARE FOR REFERENCE
- CONTRACTOR SHALL ADJUST AS NECESSARY
FOR ACTUAL CONDITIONS TO ACHIEVE MATCHED PRECIPITATION RA-FES FOR EACH ZONE.
2ND AVE SW
lit W. 0 15' 30' 60' 120' M �� 0 = o
J, SEE DRAWING L3.2 FOR x
IRRIGATION LEGEND Graphic Scale: 1" = 30'-0" W W
a k o o..
a w ofo
�n 0 a aZ.
IRRIGATION LEGEND
SYMBOL
MFG.
CATALOG NO.
DESCRIPTION
FDcv
FEBCO
850U
2" DOUBLE CHECK VALVE ASSEMBLY W/ UNIONS
O
HUNTER
ICV-101G
1" GLOBE PLASTIC BODY ELECTRIC REMOTE CONTROL VALVE
WTIH PRESSURE REGULATING MODULE
►�
KENNEDY
8561ASS
2" RESILIENT SEATED GATE VALVE
0
RAINBIRD
44-LRC
1" BRASS QUICK COUPLING VALVE (QCV) W/ LOCKING RUBBER COVER,
SUPPLY W/ COUPLER KEY & LOCKING COVER KEY
E] [E] c0
HUNTER
ACC-1200-PP
STATION OUTDOOR WITH
WEATHER STATION. WALL MOUNT ATLOCAT ON DETERMINED
BY OWNER OR OWNER'S REPRESENTATIVE.
HUNTER
FCT-100-HFS
1" SCHED. 40 PVC FLOW SENSOR, PROGRAM FOR DRIP
IRRIGATION ZONES ONLY
Q
RAINBIRD
200-EFB-CP-R
2" ELECTRIC REMOTE CONTROL MASTER VALVE
+
HUNTER
PASV-101
1" ELECTRIC DRAIN VALVE WITH FLOW CONTROL
NOI SHOWN
STATION & COMMON WIRE SIZE-AWG 14 GAUGE MINIMUM. INSTALL ONE SPARE WIRE FOR ALL
IRRIGATION ZONE WIRE RUNS. REVIEW ADDITIONAL REQUIREMENTS FOR FLOW METER &
MASTER VALVE IF NECESSARY
----�
SCHEDULE 40 PVC MAINLINE (2" SIZE UNLESS NOTED OTHERWISE) @ 18" DEPTH MIN., 24" MAX.
SCHEDULE 200 PVC LATERAL LINES, SIZE TO NOT EXCEED 7 FPS INDICATED @ 12" DEPTH MIN., 18" MAX.
CLASS 200 PVC SLEEVES @ 18" DEPTH, SIZE TO ACCOMODATE ALL PIPE
U d0
N-ald
w Z
r I
=NO
oz(n
to �ww
O U E
g - s.
x
w
M
U O
� O
Q. M
E u) d)
U��
�Q
(
U)D c�
0T
Co I'
W
D
0
n
V
Z
M
O
N
v
E
L
Q
(n
N
Q.
dj
Q
00
a7
�
Z3>OJ
Q
to
>-
a-E
O
(�
O
Lo
0
M
O
�+
JT-
O
(6
Lo
N2-2
O
N
Q.
0
E
U
_
Z
a�
as
V q.
O
(� . 0
■� L
> L
N
SEE DRAWING L3.1 FOR IRRIGATION 0 15' 30' 60' 120' M
HEAD SCHEDULE Graphic Scale: 1" = 30'-019
tl
C
u
INOUE
c
C
18" OF UNOBSTRUCTED
2" SCHEDULE
40 PVC PIPE
2
MANUAL CONTROL L3.3
VALVE
2" MAINLINE
J �=
MANUAL DRAIN VALVE —�
FLOW METER 6
L3.3
2" MAINLINE
3 2" DOUBLE CHECK VALVE
L3.3
4 QUICK COUPLER VALVE
L3.3
2 MANUAL CONTROL VALVE
36" L3.3
UNOBSTRUCTED
2" SCHEDULE
40 PVC PIPE
TAP FROM EXISTING
1" WATER METER
I I
L— — — — — — — J
5
L3.3 MASTER VALVE
POINT OF CONNECTION LAYOUT
NOT TO SCALE
SWIVEL HOSE ELL FOR HOSE FITTING ON
QUICK HOSE COUPLING VALVE KEY. PROVIDE
1 KEY FOR EACH QUICK COUPLING VALVE.
SECURE W/ STAINLESS
STEEL HOSE CLAMPS
CONNECT VALVE BOX TO PIPE
WITH DUCT TAPE - 3 WRAPS.
CLASS 200 10" PIPE
3/4" RE -BAR, 36" MIN. INTO
GROUND
1 CU. FT. GRAVEL BACKFILL FOR _
DRY WELLS
oa o
0
oa
0 0
0
00
moo
000
oo �o
o
00
0 0
a
PLASTIC VALVE BOX.
SET FLUSH W/ FINISH GRADE
SET TOP OF Q.C. 2" MIN.
BELOW FINISH GRADE.
QUICK COUPLING VALVE
SCHED. 80 NIPPLE
24" r LASCO SWING JOINT
1 ASSEMBLY
QUICK COUPLER VALVE (QCV
NOT TO SCALE
WATERPROOF WIRE SPLICE ALL WIRE
SPLICES SHALL BE WITHIN VALVE
BOXES
PVC UNION W/ SCHED. 80 PVC CLOSE
NIPPLE BOTH SIDES OF VAVLE
BALL VAVLE - SAME SIZE AS
ELECTRIC CONTROL VALVE
SCHED. 80 NIPPLE(S)
LENGTH TO FIT
SCHED. 80 TxT ELL1�/
SCHED. 80 NIPPLE
LENGTH TO FIT !
MAINLINE W/
SxSxT TEE
THREADED ELL
2" SCHED. 40
PVC MAINLINE
PLASTIC VALVE BOX, SET FLUSH W/ FINISH
GRADE
VALVE ID TAG
1 CU. FT. GRAVEL BACKFILL FOR DRY
WELLS
SECURE CONTROL WIRES TO MAINLINE W/
PLASTIC LOCK TIES. DIRECT BURY W/
MAINLINE AND INSTALL SLACK LOOP
EVERY 50 FEET.
ELECTRIC CONTROL VALVE
CENTER VA
IN]
VALVE BOX EXTENSI
AS NECESSA
SPECIFIED RESILIE
SEATED GATE VAL
LASTIC VALVE BOX.
ET FLUSH W/ FINISH GRADE
X.
2" SCHED. 40
PVC MAINLINE
`--2-PVC UNION
SCHED. 80 PVC CLOSE
NIPPLES NOTE: SIZE ALL VALVE BOXES TO ALLOW
SUFFICIENT ROOM FOR VALVE
REPLACEMENT AND MAINTENANCE.
MANUAL CONTROL VALVE
NOT TO SCALE
WIRES TO CONTROLLER
4x8" M.J. FLANGED
ADAPTER
2" SCHED. 40
PVC MAINLINE
PVC LATERAL @ 12" MIN., 18" MAX.. DEPTH
PLASTIC VALVE BOX,
SET FLUSH W/ FINISH
GRADE
ALL SPLICES IN SPECIFIED
WATERPROOF CONNECTORS
4x8" M.J. FLANGED
ADAPTER
2" SCHED. 40
f PVC MAINLINE
MASTER VALVE INSTALLATION TYP.
NOT TO SCALE
FUNNY PIPE
PLASTIC FLEXIBLE
SWING PIPE
PVC SxSxT TEE
PVC LATERAL
�-� 6" TO CONC. SURFACE OR SIDEWALK
12" TO BUILDING SURFACE
i
TOP OF HEAD SHALL BE FLUSH W/
TOPSOIL & PERP. W/ SURFACE PER
RAINBIRD SPECIFICATIONS
SPRINKLER HEAD AS SPECIFIED
NOTE: WRAP ALL THREADED FITTINGS W/
TEFLON TAPE - THREE WRAPS MINIMUM &
HAND TIGHTEN
ROTARY & POP-UP MODELS
SPRINKLER HEAD INSTALLATION - TYPICAL
PI AQTI(` \/AI \/C QnV QCT M I IQW 1Al/ CIAIlQW
24"
C.I. FLANGE
11. FLANGED REDUCER
2" SCHED. 40
��_ PVC MAINLINE
0J'
alp 2 CU. FT. GRAVEL BACKFILL
FOR DRY WELLS
DOUBLE CHECK VALVE (DCV) INSTALLATION
NOT TO SCALE
PLASTIC VALVE BOX - SET
FLUSH W/ FINISH GRADE
ENCAPSULATING
CONNECTION SEALERS
WIRES TO CONTROLLER
FLOW FROM —
MASTER VALVE
2" SCHED. 40
PVC MAINLINED
PROVIDE 36" MIN. OF STRAIGHT &
UNOBSTRUCTED 2" SCHED. 40
P.V.C. PIPE TO FLOW METER
2" FLOW METER
FLOW METER
NOT TO SCALE
12" LATERAL
18" MAINLIN
1 CU. FT. GRAVEL
BACKFILL FOR DRY
WELLS
i
U
Z =MO�W�rJ
p
IN
lliql
ZZa
�-
zzCO
Na=d'=
Q
3
TWO
Z
p
MU,
Z
Ja
JQ
x
w
C'7
O
O
Q 00
E u
N <C
U>�
�
Q
CO
rL L
V � _
0
\_ 'Cr -0
/ co u-
V
i`
O
= N
V
L a)
Q
�U
w
N
�— WIRES FROM 1 LOW
O
Q
METER
CL
't
SCHED. 40
CU �
0
"I
�2"
PVC MA'NLINE
u Q
(y)
0
!
-
ply
1
4"
4-
•U
d'
1
O
PROVIDE 18" MIN. OF STRAIGHT
O r
0
C
O
& UNOBSTRUCTED 2" SCHED. 40
�
P.V.C. PIPE DOWNSTREAM FROM
J
04
FLOW METER
NOTE: PIPE TRENCH SHALL BE NO WIDER
THAN NECESSARY TO INSTALL PIPE OR
EQUIPMENT
PIPE TRENCH
SPECIFIED TOPSOIL TYPE A AT DEPTHS AS
INDICATED ON PLAN
ACKFILL W/ CLEAN SAND
PE
DEPTH MIN.
OAND BEDDING
In
�
z
o
w
�L
L
NOT TO SCALE NOT TO SCALE y NOT TO SCALE
LL-
O
M
M
J
LL
i �
i a 4
0 C=..
W
O
N
N 4
L a
N (,
E LL
l y C
>
z >
L
LL.
W
W C
a a
a a
C,
1 a
IRRIGATION SPECIFICATIONS & NOTES
GENERAL
1. WORKMANSHIP
A. Installer qualifications: System to be installed by an irrigation technician with 5 years of experience as
an irrigation installer. All workmanship shall be of the highest standards of the industry.
B. Workmanship that is improper, careless, and or that does not meet specification, will be rejected. The
replacement or replacement cost shall be at the expense of the Contractor.
2. SCOPE OF WORK
A. Furnish all labor and materials to install the irrigation system complete as shown on the plans and
details, and as specified herein.
B. This work includes all phases of completing and making the irrigation system fully operational, as -built
plans and an orientation meeting with the Project Landscape Architect or Owner's Representative.
3. SUBMITTALS
A. Submit each item in this specified to the Landscape Architect.
B. The Contractor shall provide the Project Landscape Architect a complete listing of all irrigation materials
required by this Section to be used on the project.
C. The listings shall include the name of the manufacturer, trade names, catalog cut sheets, specifications,
model numbers, brochures and other data giving information about each item specified.
4. DAMAGE TO PROPERTY
A. The Contractor shall be responsible for all damage to any part of the premises caused by breaks or
leaks in the system for a period of one (1) year after final acceptance of the contract.
B. The Contractor shall be responsible for the clean up and removal of any building materials, equipment
and trash resulting from his/her work. The Contractor, upon completion, shall leave the property in a
clean and orderly condition.
1. CONDITION OF MATERIALS
A. All materials to be installed on this project shall be new and free of defects.
2. WATER METER
A. Anew 1-inch water meter will supply the irrigation system.
3. BACKFLOW PREVENTION DEVICE
A. Install new device, as shown on the drawings and details. Per City of Federal Way requirements.
4. QUICK COUPLING VALVES
A. Install per plans and details.
5. PVC PIPE, FITTINGS, NIPPLES
A. Install per plan.
B. Pipe shall be marked with manufacturer's name, class of pipe, NSF seal and date of manufacturer run.
Pipe shall bear no evidence of interior or exterior extrusion marks. Pips; walls shall be uniform, smooth,
and glossy. Pipe may be pre -belled or with individual solvent -weld couplings for laterals. Class 200
pipe shall have SDR rating of 21.
C. PVC fittings shall be schedule 40 rated and meet ASTM D2466 standards and specifications.
D. PVC nipples shall be schedule 80 rated and meet ASTM D1785 requirements and standards. All
nipples will have tapered threads.
6. JOINING MATERIALS
A. All joining materials used will be manufactured by IPS or equal, and will be used in accordance to the
manufacturer's written specifications and safety recommendations.
B. All threaded connections (PVC) shall be sealed using Teflon tape.
C. All galvanized threads shall be sealed with an approved Teflon base pipe compound.
D. PVC solvent compounds shall be IPS Weld -On P-70 purple primer and Weld -On P-711 heavy -bodied
gray cement or approved equal.
7. GALVANIZED PIPE AND FITTINGS
A. Galvanized steel pipe shall be schedule 40, hot dipped galvanized, conforming to ASTM-A120-76
specifications.
B. Galvanized fittings shall be of malleable iron, hot dipped galvanized.
C. Galvanized pipe, nipples and fittings shall be of domestic origin.
8. CONTROL WIRE
A. Control wire shall be 14 ga. solid copper wire, to be OF rated and UL listed. Use Red wire for leads,
White wire for common, Black wire for spare, and Yellow wire for Master Valve.
B. Wire connectors shall be 3M DBY, or approved equal.
C. PE-89 Maxi cable shall be used to connect the flow sensor to the controller. Ranger Seal Closures shall
be used when connecting to the flow sensor.
9. TRACE WIRE
A. Trace wire shall be 12 ga. solid bare copper wire, to be OF rated and UL listed.
10. VALVE BOXES
A. Valve boxes for master valves and control valves shall be Carson -Brooks, green plastic HDPE box,
High Performance Series Model 1419-12 with 1419-3B locking cover, or approved equal. The cover
shall be bolted down with stainless steel bolts. Box and cover to be green. Valve box extensions shall
be compatible with valve box, and used as needed to meet finished grade.
B. Valve boxes for mainline gate valves and quick coupler valves shall be Carson -Brooks, green plastic,
mode 910-12 with 910-413 bolt down T cover or approved equal, 10 inch diameter circular boxes with 7
inch diameter PVC sleeve below. Cover is to be green and marked "Irrigation".
C. Valve boxes for the backflow device shall be stacked concrete meter boxes, per City of Federal Way
requirements.
11. AUTOMATIC CONTROLLER REMOTE CONTROL DEVICE & ACCESSORIES
A. Controller and accessories shall be those shown on the drawings.
B. Install on exterior wall as directed by Owner's Representative. Shall be wall mounted at chest height.
12. AUTO -CONTROL VALVES
A. Per Plans and Details.
13. FLOW SENSOR
A. Per Plans and Details.
14. SPRINKLER HEADS
A. Per Plans and Details.
15. DRIP IRRIGATION
A. Per Plans and Details.
16. VALVE IDENTIFICATION TAG
A. Polyurethane identification tag shall be as supplied by T. Christy, model No. ID-STD-YI or approved
equal
17. NOT LISTED EQUIPMENT
A. Not all materials needed for the completion of this irrigation system have been listed. It shall be the
Contractor's responsibility to furnish and install any items required to complete this irrigation system as
designed, detailed and specified.
EXECUTION
1. CONSTRUCTION CONDITIONS
A. Location of sprinklers, valves and other items shall be as shown on the plans and will be of the size and
type as specified. No changes in the plans or the equipment will be made without prior approval of the
Project Landscape Architect.
B. Electrical connections shall be made by the Contractor as indicated on the plans and specifications.
Installations shall conform to local codes and utilities. Coordinate with Project Landscape Architect or
Owner's Representative and Electrical Contractor for arranging power to the controller and final
controller location.
2. LAYOUT
A. The Contractor shall stake the system from the design show on the plans. Some alternations may be
required to accommodate site conditions to ensure good application rates. It is known that corrective
measures in the system, if any, shall not be made without the written approval from the Project
Landscape Architect or Owner's Representative.
B. The Contractor layout and staking shall be approved by the Project Landscape Architect or Owner's
Representative prior to trench excavation or equipment installation.
3. EXCAVATIONS
A. It is the Contractor's responsibility to locate all underground utilities before any excavation begins. Any
damage caused by the Contractor will be repaired at his/her expense.
B. Trenches shall be wide enough to allow ample room for pipe and wire installation. When more than one
pipe occupy the same trench, each pipe must be parallel to each other, not crossing, at a minimum of
3" apart.
C. All piping under paved areas shall be installed in PVC sleeves as indicated in the drawings. All
sleeving shall be bedded with sand and a minimum depth of 6" under and 6" over pipe sleeves.
Contractor shall provide more than one 4" sleeve to accomodate pipes if necessary.
D. Mainline shall be installed at a minimum depth of 18", maximum depth of 24".
E. Where multiple irrigation pipes share a common trench, trench shall be sufficiently wide or piping shall
be arranged to allow 2" minimum horizontal separation and 6" minimum vertical separation between
piping, while maintaining specified minimum and maximum cover over piping.
4. BACKFILLING
A. All materials to be used as backfill over pipes and around valve boxes, and vault must be fully
compacted to eliminate future settling. All backfill in structural (non landscape) areas shall be
compacted as specified.
B. All material used as backfill must be clean of all debris and rocks larger than 1" in diameter. Such
debris and rocks shall be gathered and removed from the site.
5. PVC PIPE LINES
A. Install pipe as shown on drawings and details.
B. PVC pipe shall be installed on flat bottom trenches in a manner as recommended by the manufacturer
to allow pipe to expand and contract.
C. All pipe shall be cut with a hand saw/hack saw in a manner to provide square ends. All shavings and
burrs must be removed before welding pipes or fittings.
D. Flush main free of all debris and shavings prior to installing ACV's. Flush all laterals prior to installing
sprinkler heads.
E. Contractor shall exercise care when loading, hauling and handling pine. Damaged pipe will not be
accepted or used on this project.
F. Install sleeves under paved surfaces (all hard surfaces) to allow for ir ilgation piping and electrical
wiring. Sleeve ends shall be sealed.
G. Allow minimum 15 minutes setup time for solvent weld joints before moving or handling. Pipe shall be
partially center loaded to prevent arching or slipping. No water shall be permitted in the pipe for at least
10 hours to allow solvent weld set and cure. Backfilling shall be done when pipe is not in an expanded
condition due to heat or pressure. Cooling of the pipe can be accomplished by operating the system for
a short period of time before backfilling or by backfilling the early part of the morning before the heat of
the day. Before pressure testing, allow 24 hours cure time for solvent weld joints.
6. SOLVENT WELD JOINTS
A. All solvent weld joints must be first primed and then welded per manufacturer's recommendations.
B. The pipe and fittings shall be clean of all foreign matter and water before solvent can be applied.
C. Contractor shall not be allowed to weld mainline pipe with a 'one step' glue such as IPS 721 or 725 or
equivalent.
7. POINT OF CONNECTION
A. Per Drawings and Details.
8. CONTROL WIRE
A. Wire shall be pulled from valve location to controller location in one continuous piece.
B. Wire shall be grouped together, taped with electrical tape at 10' intervals. Wire then will be installed
under main line or laterals in a soft snaking manor to prevent copper from being stretched and or
damaged.
C. Coil a minimum of 5' of each wire in each valve box.
D. No file wire splices shall be allowed between valve boxes. All wiring connections shall bed installed in
valve boxes or separate handhole.
9. CONTROLLER
A. Controller shall be wall mounted as detailed. Coordinate exact location of controller with Owner.
B. Coordinate with the Electrical Contractor to ensure proper connection of controller to power.
10. AUTOMATIC CONTROL VALVES
A. Per Drawings and Details.
B. Contractor shall install one valve assembly box.
C. All valve boxes shall receive a polyurethane identification tag identifying the valve station number.
Valve number shall be marked on exterior of valve box lid with a minimum 1" letters.
11. VALVE BOXES
A. Install all other boxes plumb and flush with finish grade. Valve box archway shall not rest on piping.
Provide a minimum of 1" clearance around the inlet and outlet pipe.
12. SPRINKLER HEADS
A. Contractor shall install sprinklers as detailed on the drawings.
B. Placement of heads shall be 4" from edge of paving/concrete edge.
13. TESTING OF SYSTEM
A. After flushing and valving main line prior to backfilling, a pressure test will be required on the main line.
B. Mainline shall have a one hour test at a pressure of 150 PSI. A maximum pressure loss of 5 PSI is
allowed.
C. Contractor is responsible to set up all equipment necessary to comply with test.
D. Contractor shall schedule pressure test 48 hours in advance with Project Landscape Architect or
Owner's Representative.
E. Lateral lines shall be visually tested before heads are installed at line pressure. Schedule pressure
tests on lateral with Project Landscape Architect 48 hours in advance.
F. Before any testing starts, all air must be expelled from the pipe.
G. Any section of pipe not passing pressure test shall be repaired and retested.
14. PRODUCTS TO BE PROVIDED TO OWNER
A. The following list of materials shall be provided to the Owner at the time of project completion: (2) QCV
Keys - Manufacturer to match installed Quick Couple Valve. (2) Hose swivels - Manufacturer to match
installed Hose Swivels. (2) 20" sprinkler keys. Spare irrigation body, riser and nozzle for each type
specified.
15. PERFORMANCE TEST
A. A performance test is part of the final review.
B. Upon completion of the system installation and after the flushing and pressure tests have been
completed and the system has been adjusted, the Contractor shall operate the system in the presence
of the Project Landscape Architect or Owner's Representative.
C. Coverage Check: Each automatic valve shall be operated to determine complete sprinkler coverage,
D. The Project Landscape Architect or or Owner's Representative may direct that up to 5% of the total
nozzles be substituted, at no additional cost to the owner.
RECORD DRAWINGS & GUARANTEE
1. ADJUSTING SYSTEM
A. Before final inspection, the Contractor shall adjust and balance all sprinkler to provide adequate and
uniform coverage. Spray patterns shall be balanced by adjusting individual sprinkler heads with the
adjustment screws or replacing heads to produce a uniform pattern.
B. Sprinkler spray patterns shall not be permitted on pavement, walks or structures.
2. AS -BUILT PLANS AND SYSTEM ORIENTATION
A. Contractor shall maintain a set of drawings on the site specifically for recoding changes as they occur
during the job.
B. The Contractor shall conduct a training and orientation session covering the operation, adjustment,
winterization and maintenance of the irrigation system. The Contractor shall provide the owner with a
parts list and service manuals for all equipment. Contractor shall be responsible for one fall
winterization and one spring activation of the system and shall conduct these operations as part of the
Owner's training and orientation procedure.
C. Contractor shall provide a zone control map encased in plastic and mounted next to the Controller. The
map will show main and zone valves and the area they cover.
3. MAINTENANCE AND GUARANTEE
A. The Contractor shall provide a written guarantee to the Owner covering all materials, installation,
workmanship, and against defects for a period of one (1) calendar year upon final acceptance by the
Project Landscape Architect. Contractor shall be responsible for maintaining system and protecting it
from all damage, at no cost to the owner, for the duration of the maintenance period, including damage
caused by vandalism or adverse weather conditions.
E
co
V
O
L.
o
U
^p
a N
V Z 2
�M
O1M_
}
O F- R
w
J
aN�d
ZZOD
0Z
`U �3=0
owrn
2O,
O
Z
Ja
x
w
M
U O
� O
11 00
E uj (A
(5Q
Ua)3:
Q
N N (CS
Ur U >
N a)
> ccyi li
� Z
z w o
O U
05 Q W s
0 0 0 0 �
d'
M
U7 y C
(1)o
Q Z >
W w
a �' o
U Q �
U) p a
Lv
D
O
CL
00
CV
N