19-105427CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT DEPARTMENT
DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL
DATE:
TO
FROM:
FOR DRC MTG. ON:
FILE NUMBER (s) :
RELATED FILE NOS.:
PROJECT NAME:
PROJECT ADDRESS:
ZONING DISTRICT:
November 22% 2019
Cole Elliott, Development Services Manager
Greg Kirk, Building Plans Examiner
Rick Perez, City Traffic Engineer
Brian Asbury, Lakehaven Water & Sewer District
Chris Cahan, South King Fire & Rescue
Natalie Kamieniecki, Associate Planner
Please provide technical comments via email
19-105427-UP
None
WELLS FARGO ATM
2300 SW 336TH ST
BN
PROJECT DESCRIPTION: Installation of freestanding ATM at Twin Lakes
Shopping Center.
LAND USE PERMITS:
PROJECT CONTACT: ANDREA RIOS
CIM GROUP INC
MATERIALS SUBMITTED: Master Land Use Application
Project Request Narrative
Title Report
Site Photos
Site Plans
**If you did not receive a document on the above list and would like a copy
please let me know**
CITY OF
Federal Way
RECEIVED
NOV 12 2019
CiTy
CDM UNITY pa Mom.
MASTER LAND USE APPLICATION
DEPARTMENT OF COMMUNITY DEVELOPMENT
33325 8"' Avenue South
Federal Way, WA 98003-6325
253-835-2607;Fax 253-835-2609
www.c.ity ffecleralwa .corn
APPLICATION NO(s) / 9 5 705 ! i P! Date — id- / 4)
Project Name WELLS FARGO BANK NEW ATM -TWIN LAKES SHOPPING CENTER
Property Address/Location 2300 SW 336TH ST. FEDERAL WAY. 98023
Parcel Number(s) 132103-9097
Project Description INSTALL ATM WITH NEW ATM KIOSK AND ASSOCIATED WORK.
rice-4 1
Type of Permit Required
_ Annexation
Binding Site Plan
Boundary Line Adjustment
Comp Plan/Rezone
Land Surface Modification
Lot Line Elimination
Preapplication Conference
X Process I (Director's Approval)
Process II (Site Plan Review)
Process III (Project Approval)
Process IV (Hearing Examiner's Decision)
Process V (Quasi -Judicial Rezone)
Process VI
SEPA w/Project
SEPA Only
_ Shoreline: Variance/Conditional Use
Short Subdivision
_ Subdivision
Variance: Commercial/Residential
Required Information
BN Zoning Designation
Comprehensive Plan Designation
Value of Existing Improvements
Value of Proposed Improvements
International Building Code (IBC):
U Occupancy Type
VB Construction Type
Applicant
Name: CIM GROUP, INC. / ANDREA RIOS
Address: 960 E DISCOVERY LN
City/State: ANAHEIM, CA
Zip: 92801
Phone: (714) 956-2827
Fax: (714) 956-8157
Email: arios@cimgroupinc.com
Signature:
Agent (if different than Applicant)
Name: Same as above
Address:
City/State:
Zip:
Phone:
Fax:
Email:
Signature:
Owner
Name: TL FKC AU LLC - TWIN LAKES VILLAGE
Address: PO BOX 997
City/State: SNOQUALMIE, WA
Zip: 98065-0997
Phone:
Fax:
Email:
Signature:
Bulletin #003 —January 1, 2011 Page 1 of 1 k:\Handouts\Master Land Use Application
(:IBAGROUP INC
KNOWLEDGE I DUALITY I EXPERIENCE
Wednesday, October 30, 2019
City of Federal Way
Community Development Department
33325 81 Avenue South
Federal Way, WA 98003
RECEIVED
NUV 12 2019
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
Request: Use Process I to allow for a ATM Drive -Up Island.
Wells Fargo is proposing to install a new drive -up island automatic teller machine at 2300
SW 336th St. in the Twin Lakes shopping center parking lot adjacent to the Jack in the Box.
At present the nearest Wells Fargo ATMs are 2.04 miles East at 914 S 34P St, 2.47 miles
North-East at 1424 S 3201 St and 4.44 miles North-East at 27525 Pacific Hwy S. The
purpose of the new drive -up island ATM is to alleviate ATM usage at the afore noted ATM
locations and provide closer access to ATM services and reduce traffic to and from the afore
noted ATM locations.
The use will be in compliance with all provisions of the City of Federal Way Community
Design Guidelines (FWRC chapter 19.115) and shall not cause an adverse impact on adjacent
property or properties in the area. Adverse impacts would include, for example: a significant
increase in vehicular or pedestrian traffic in adjacent residential areas; emission of odor, dust,
gas, noise, vibration, smoke, heat, or glare at a level exceeding ambient conditions;
contribution in a measurable way to the deterioration of the area or contribution to the
lowering of property values.
Yours Sincerely,
James C Spix
Engineering Project Manager
CIM GROUP, INC.
CORPORATE OFFICE
960 E. DISCOVERY LANE
ANAHEIM, CA 92801-1149
714.966.2827
WELLS FARGO BANK
NUV 12 2019 OPT A — Twin Lakes Shopping Center
CITY OF H DERAL. WAY
UMUNkTY 6EVELQPMENT
1) Parking Lot Entrance
3) Path of Travel to Proposed ATM Lane 2
5) Proposed ATM Lane
2) Path of Travel to Proposed ATM Lane 1
4) Path of Travel to Proposed ATM Lane 3
4 s. l
:z
�rcr 1
6) Proposed Behind Back Left
1
WELLS FARGO BANK
OPT A — Twin Lakes Shopping Center
7) Proposed Behind Back
9) Proposed Drive -Up Lane Exit
11) Path of Travel to Electrical Room 2
maw*fir
..
AL
r
1
8) Proposed Behind Back Right
10) Path of Travel to Electrical Room 1
2
12) Path of Travel to Electrical Room 3
WELLS FARGO BANK
OPT A — Twin Lakes Shopping Center
i
13) Path of Travel to Electrical Room 4
15) Path of Travel to Electrical Room 6
r•�
1n4 Ri rp Vr ri
ligp 4
um'
's
i
14) Path of Travel to Electrical Room 5
x
V4G£0
CUIEfl
16) Electrical Room Entrance
17) Electrical Room 18) Meters 1
3
I
WELLS FARGO BANK
OPT A — Twin Lakes Shopping Center
AL
19) Meters 2
1
21) Telco
23) Electrical Circuits
11 -
20) Meter Socket
t7<
.l
6.,
22) Electrical Panel
I
I
1
El
1
4
WELLS FARGO BANK ATM - TWIN LAKES SHOPPING CENTER
&
AND
E.S.
EACH SIDE
(R/R)
REMOVE & RELOCATE
@
AT
E.W.
EACH WAY
(RE)
RELOCATED
A.B.
ANCHOR BOLT
EXT, EXTR
EXTERIOR
RE:
REFER TO
1 NOTE #
KEYNOTE SYMBOL
ABV
ABOVE
FIN
FINISH
REINF
REINFORCING
A.F.F.
ABOVE FINISHED FLOOR
FLG
FLANGE
REQ'D
REQUIRED
AGL
ANGLE
FLR
FLOOR
REQM'TS
REQUIREMENTS
A
ALT
ALTERNATE
FND
FOUNDATION
RF
ROOF
BLDG
BUILDING
F.F., F/F
FINISH FACE
SCHED
SCHEDULE
1
GRID REFERENCE
BLKD
BLOCKED
F.F.O.
FINISH FACE OF
SIM
SIMILAR
BLK'G
BLOCKING
F.O.
FACE OF
SMS
SHEET METAL SCREW
BLW, BEL
BELOW
F.O.C.
FACE OF CONCRETE
S.O.G.
SLAB ON GRADE
BM
BEAM
F.P.
FULL PENETRATION
SPCG
SPACING
B.O.
BOTTOM OF
FRMG
FRAMING
SQ
SQUARE
N
NORTH ARROW
B.O.W.
BOTTOM OF WALL
FTG
FOOTING
STGRD
STAGGERED
TRUE NORTH
BOT.
BOTTOM
GA
GAGE
STIFF
STIFFENER
BRIG
BEARING
GALV
GALVANIZED
STL
STEEL
DETAIL #
BTWN, BET
BETWEEN
GRD
GRADE
STRUC
STRUCTURE
DETAIL REFERENCE
C=
CAMBER
HDR
HEADER
STRUCT, STR
STRUCTURAL
SHEET #
C.I.P.
CAST IN PLACE
HORIZ, (H)
HORIZONTAL
T&B
TOP & BOTTOM
C.J.
CONSTRUCTION JOINT
HGT
HEIGHT
THD
THREAD
SECTION
C/L
CENTER LINE
H.S.B.
HIGH STRENGTH BOLTS
T.O.
TOP OF
SECTION
CLR
CLEAR
INT, INTR
INTERIOR
T.O.C.
TOP OF CONCRETE
SHEET #
COL
COLUMN
JNT
JOINT
T.O.F.
TOP OF FOOTING
CONIC
CONCRETE
JST(S)
JOIST(S)
T.O.S.
TOP OF STEEL
ELEVATION
CONN.
CONNECTION
LB, #
POUND
T.O.W.
TOP OF WALL
EXTERIOR ELEVATION
CONST
CONSTRUCTION
LG
LONG
TRANS
TRANSVERSE
SHEET #
CONT
CONTINUOUS
LONGIT
LONGITUDINAL
TS
STRUCTURAL TUBING,
CSK
COUNTERSINK
MAX
MAXIMUM
(TUBE STEEL)
A'� ELEVATION
DBL
DOUBLE
M.B.
MACHINE BOLT
TYP
TYPICAL
ROOM #
DIA, 0
DIAMETER
MIN
MINIMUM
U.N.O.
UNLESS NOTED OTHERWISE
INTERIOR ELEVATION
DIAG
DIAGONAL
NIC
NOT IN CONTRACT
VERT, (V)
VERTICAL
SHEET #
DLT
DEEP LEG TRAC
(N)
NEW
W/
WITH
DWG
DRAWING
O.C.
ON CENTER
W/O
WITHOUT
A
SCOPE OF WORK NOTE
(E), EXIST
EXISTING
O.H.
OPPOSITE HAND
W/R
WATER RESISTANT
DWL
DOWEL
OVR, O/
OVER
WHS
WELDED HEADED STUD
ROOM
EA
EACH
OPEN'G
OPENING
W.P.
WORK POINT
101
ROOM NAME
E.F.
EACH FACE
PC
PIECE
W.S.
WOOD SCREW
EL, ELEV
ELEVATION (DATUM)
P/L, PLT
PLATE
WT, WGT
WEIGHT
O
DOOR REFERENCE
EMBED
EMBEDMENT
P.T.
PRESSURE TREATED
W.W.F.
WELDED WIRE
(R)
REMOVE
FABRIC
O
WINDOW REFERENCE
ABBREVIATIONS
Dept of Assessments aSE 13-21-03
— s""'' `� ^�� �>a
—co,w...ti<a r o`�� �.._wdwu..s,.-_
Iv-
4 _ LA EPA K DIV. BA
,
t` a
x.
-f< VV LAGEP`AV.'B
VILLA E ALDERBROOK
PARK
DIV.4
VjLtAdE
m
_
,d
^ e.
� PARK r
V
o
i F 5 '�� a Gy¢a. i tcar—na.s wmm =
* .. ,. �� A•8 A �; � Jay .t s
... 5 z.. sN,• _ A.
x
I
TWIN LAKES HOPPING 4EM'ER SOUTH '
,
PARCEL MAP
DETAILED PLAN/
ENLARGED AREAPLAN
— — PROPERTY LINE
CENTER LINE
DATUM/BENCH MARK
00 BREAK LINE
CONCRETE WALL
MASONRY WALL
EXISTING 2x4 OR 2x6
WALL TO REMAIN
EXISTING WALL/AREA TO
BE REMOVED
NEW 2x4 OR 2x6 WALL
TO BE CONSTRUCTED
SYMBOL LEGEND
V�
,. 2300 SW
336th St --
3
SW 34Cth St 5\C, 340th St " y
"
i. 1� i N '�
—e`SW'34b P ,.-
TF
�_
... a ...SW-
•St•-�
i 41.
_
VICINITY MAP
PROJECT ADDRESS
2300 SW 336TH ST
FEDERAL WAY, WA 98023
PARCEL NUMBER
132103-9097
ZONING
BN
PROPERTY TYPE
C
OCCUPANCY CLASSIFICATION
U
CONSTRUCTION TYPE
VB
LAND Sq.Ft. / ACRES
154,341 Sq.Ft. / 3.54 Ac
QUARTER -SECTION -TOWNSHIP -RANGE
SE-1 3-21-3
LEGAL DESCRIPTION
LOT 3 TGW POR LOT 2 BEG SW COR OF SE 1/4 TH N 00-57-39 E 42 FT TAP ON NLY LN OF
SW 336TH ST TH S 88-46-50 E 1035.82 FT TO TPOB TH N 00-58-28 E 169.27 FT TH S 88-47-49
E 250 FT TH N 00-58-28 E 118 FT TH N 88-47-49 W 690 FT TH S 00-58-28 W 240 FT TH S
89-01-32 E 19.0 FT TH S 00-58-28 W 47.22 FT TH S 88-46-50 E 421.0 FT TO POB OF SD LOT 3
KCSP-1 178051 -R REC # 8501140624 SD PLAT DAF - POR OF SE 1 /4 BEG SW COR OF SE 1 /4
TH N 00-57-39 E 42 FT TAP ON NLY LN SW 336TH ST & TPOB TH CONT N 00-57-39 E 286.97
FT TH S 88-47-49 E 1285.89 FT TAP ON WLY LN 21 ST AVE SW TH S 00-58-28 W ALG SD WLY
LN 262.23 FT TH ON CRV TO RGT RAD 25 FT THRU C/A OF 90-14-42 ARC DIST OF 39.38 FT
TAP ON NLY LN SW 336TH ST TH N 88-46-50 W ALG SD NLY LN 1260.72 FT TO TPOB - AKA
LOT B KC-LLA 8606007 APPROVED 6-4-86 - LESS POR FOR RD
CODES
2015 International Building Code
2015 International Residential Code
2015 International Mechanical Code
2015 International Fire Code
2015 Uniform Plumbing Code
2015 Washington State Energy Code
National Electrical Code (NEC) Amendments
PROJECT DATA
EXISTING RENDERING
ll'c-i"
FARGO s
PROPOSED RENDERING
OWNER
TL FKC AU LLC
TWIN LAKES VILLAGE
PO BOX 997
SNOQUALMIE, WA 98065-0997
PROJECT PROPONENT
WELLS FARGO BANK
525 MARKET STREET
21 ST FLOOR
SAN FRANCISCO, CA 94105
GENERAL CONTRACTOR
CIM GROUP, INC.
960 E DISCOVERY LANE
ANAHEIM, CA 92801
714.956.2827
o
co
N
00
LO
,
00
t
z
Q
-
LC)
rn
t
w
Z LU
� X
E
a,
�
tiS
T
..
X
c�
Cz
N
CO
O o
J
N
L0
�W
>
0
U
/�
V e
o
T
'�
w
0
rn
0
a
W
J
w
PROJECT TEAM
a
�
W
O
INSTALL ATM WITH NEW ATM KIOSK AND ASSOCIATED WORK.
o
z
U
J
a
PROJECT OVERVIEW
W
-�
cc
W
O
z
SCOPE OF WORK:
W
• REMOVE (1 1) EXISTING PARKING STALLS.
a.
C�
• DEMO PORTION OF EXISTING ASPHALT.
'
• FORM & POUR NEW ATM CONCRETE ISLAND.
• INSTALL NEW NCR 6688 ATM.
• INSTALL NEW WFB3885 ENCLOSURE.
• INSTALL NEW VHD "VEHICLE HEIGHT DETECTOR".
• INSTALL (5) NEW BOLLARDS w/ COVERS.
W
• INSTALL NEW PEDESTAL.
�—
• INSTALL NEW LIGHT POLE w/ (2) NEW L.E.D. LIGHT
z
FIXTURES.
W
• PAINT NEW LANE STRIPING & DIRECTIONAL ARROWS.
(�
• PAINT NEW "ENTER ONLY" & "EXIT ONLY" LETTERING.
ATM AREA: 14.20 SQ. FT.
z
z
a—
CL
00
M
00
V
Ir
a
U
a
-
U.
W
2
SCOPE OF WORK
a
j
M
J M
J
GENERAL INFORMATION
_I
Z �
a
LL
AO.0 GENERAL INFORMATION
W
—
0
W
ARCHITECTURAL
�— N vi
0
LL
A1.0 SITE PLAN
A2.1 PLAN VIEW (EXISTING)
PLAN VIEW (PROPOSED) DRAWN: A.RIOS
JOB: TWIN LAKES
GENERAL DETAILS """ SCALE: NOTED
Wa
D1 REFERENCE DETAILS City of Federaly DATE: 08/13/2018
ELEVATION Dept. of Community Develop,
ISLAND DETAILS Permit # ry
D2 REFERENCE DETAILS B
REV
D3 ACCESSIBLE SPECIFICATIONS
Date Zr3A
ELECTRICAL
E1 ELECTRICAL PLAN RECEIVED
ELECTRICAL DIAGRAM R
REFERENCE DETAILS
NOV 12 2019
E2 ELECTRICAL DETAILS
ATTACHED CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
1 —7 ENCLOSURE MANUFACTURED DRAWINGS
- AO.0
SHEET SCHEDULE of 8
.,acne
1265.52
6,46
I
I
EXISTING i
TRASH BIN 1
I
o i 24,525 BLDG. SQ. FT.
r'qI I
�I I
I
I
PRO CLEANERS
H&R BLOCK
I
KCe L LA. KCe Le .A. 8606007 I—T'T
1
I 1
I
17'-3Q"
L"'), J 8501140624
154,341 Sq.Ft.
132103-9097 3.54 A
EXISTING CONSTRUCTION TYPE: VB KC.SP. 1 178051 R
FIRE HYDRANT OCCUPANCY CLASSIFICATION: U
I( 0/ Q
v
ti
,)
Un k2
I
NG
TRASH BIN GREASE
MONKEYe
3 384 BLDG. SQ. FT. 1
00
DENTISTRY
I
I
I
EXISTING 1
FIRE HYDRANT
�I
1
001
N LO
EXISTING
'
RANSFORM
1 (
j
oo��
I i
���
s,
EXISTING
/
,`� 1
of 1
�
FIRE HYDRANTo0
N
1
00
N
l
®® `n1Ln
3-4
1
1
0
I
127' EXISTING `��
TRASH BIN
I
IT
r
Ij EW ATM
KFC EXISTING
om i 2,280 BLDG. SQ. FT, TRANSFORMER
I U,
0 I
I 1
flQ�
15434'
3.54 /
9097
I m
1 421 LLA - -
25 � 43.1--
EXISTING 20121114001713
FIRE HYDRANT 1301,53 TO CL 21 ST. AVE. S.W.
3 3 6TH ST
kr, I
256 RD. ESMT.
I
250
- - S 88-47-
iin
LOT 4
132103-9024
226.13
20121218000290
EXISTING /
FIRE HYDRANT
I
I
I
I
N
�1
N 1
I
BANK OF 6 67 1
AMERICA 1
15.;'1
39294#
9024
�D
w
Q
U)
0.
i- ° r l
PLANNING
City of Federal Way
Dept. of Communi,tyDevelopmerft
Permit " 25 7"L". �
Date
BUILDING SQUARE PARKING REQUIRED EXISTING PROPOSED
FOOTAGE CALCULATION SPACES SPACES SPACES
33,829 4/1000 (SECTION 17.27.020) 142 (1:37+5 ADA) 159 (153+6 ADA) 148 (142+6 ADA)
PROPOSED SITE CONDITIONS MEET THE PARKING REQUIREMENTS (+6 SPACES)
O
00
N
O
ti
,
p
VQ
z
v
CO
LO
O�
w
Zw
X
�
N
T
a7
C
a
LL
U
�
(Q
00
07
_J
,,
N
CO
LO
�
ucc
U
y
O
U
0')w
O
Q
T
r
W
O
�p
O
c
0
.0
n
z
Q
d.
w
C i
W
z
W
U
i
zz
Q
-
m
a"
p
p
cr)
�R
V
T
_L00
N
o
cy)
Q
�coc
Cn
Q
LL
W
�e
Q
Q
(C)
J
z
�
Cn
Q
L.v
_
ocy)
W
I-
N
LL
DRAWN: A.RIOS
JOB:
TWIN
LAKES
SCALE:
NOTED
DATE:
08/13/2018
REV
N SITE PLAN
SCALE: 1 "=30'-
O Al .0
OF 8
SCOPE OF WORK:
1. EXISTING PARKING STALLS (11) TO BE
REMOVED.
2. EXISTING PORTION OF ASPHALT PAVING
TO BE REMOVED.
3. EXISTING WHEEL STOPS TO REMAIN.
4. EXISTING PLANTER AREA TO REMAIN.
co
T
3
1
"
vM t Z
,
v a ''q�__'-
o
ao
N
0)
Lo
,
�
a
z
a
(0
Lr)
W
Z w
X
w_
eU�
�
N
T
�.
X
0
LL
_ _
co
N
O7.o
Lo
w
u
O
z
0C)
T
IW
w co
0
00-1-
f---------------------------- - 0
I I I I z 0
3' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2 O
g' 9' x
w Q-
99,
10
N w w
z z
NG PLAN VIEW
Q J J
O�EX'ST' SCALE:1 /2" = 1'-0"
SCOPE OF WORK: p
1. FORM & POUR NEW ATM CONCRETE ISLAND. D1
2. FORM & POUR NEW LIGHT STANDARD BASE 3
E1
3. INSTALL NEW UTILITY PEDESTAL. 6
E2
4. INSTALL NEW CONCRETE FILLED STEEL BOLLARDS F
WITH COVERS. D1
H
5. INSTALL NEW VEHICLE HEIGHT DETECTOR. D2
6. INSTALL NEW NCR MODEL 6688 ATM. E
D1
G
7. INSTALL NEW MODEL WFB3885 ATM ENCLOSURE. D2
4
8. INSTALL NEW LIGHT STANDARD. E1
9. INSTALL NEW L.E.D. LIGHT FIXTURES. 5
E1
3'
10. PAINT NEW LANE STRIPING.
11. PAINT NEW DIRECTIONAL ARROWS.
12. STENCIL NEW 12" "ENTER ONLY" & "EXIT ONLY"
LETTERING.
O�PROPOED PLAN VIEWCALE: 1/2" = 1'-0"
10
ONLY
24'
F-
N
rd
fir. jy �Ki� �'•
i4h-
2
8
9 0 -
Q II
0 0-
II
II
7
51'
99,
5
"
It
10
12
NTE R
ONLY
24'
APPROVED
PLANNING
City of Federal Way
D.opt. of Community Develop
Date
rr
w
z
w
U
r�
Z
z
co
�
CL
p
0
M
V00
Q
U)
w
Q
3:
LL
F-
Q
J
J
z��
M
�a
W
>
p
q
I—
N
L.L
DRAWN:
A.RIOS
JOB:
TWIN LAKES
SCALE:
NOTED
DATE:
08/13/2018
REV
A2.1
OF 8
(N) VH
(N) BOLLARD x5
9'-5"
(N) LIGHT
---- STD
Im
o
00
N
°'
LO
,
T
6"
18'
ol 2' 2'-X 2' 2' 9 4'-7" 40 4'-8"
W
0_
Z
¢
U
Ln
rn
�
B
W
X
}
2
�
�
¢
T
_
8$tZ
"
1 �_22,�
0,�
2,_28„
8$„
/� T�
/"�
Q
®�
O
aj
J
w
(V
WELLS
_
N
T,�
BLOCKOUT
Nt
T
o
w
Uo
Y
>
0
o
Ln
CA
FA 1L�0
T
T
-�
T
_
w
(
c
O
I L
WELLS
FARGO
(N) PEDESTAL T
T
VHD STANDARD STUB -UP AND ENCLOSURE BOLLARD PEDESTAL
RACEWAY
GRADE
_ rr
O J J
v #5 @ 8" EACH WY v #5 @ 8" EACH WY
0 TOP & BOTTOM � � TOP & BOTTOM
DO •• .: :. '•i 'r - '.' •f 1 is
r
a ,
4
1.. .!.
f
•
T T
f
N /
Lq
QD
jLL
,�j///
co -� 3" CLR i0 J
7' U 8' 3' U 3" CLR
81„
dLAND
(N) 8 co 18' 4'
SECTION 'A -A'
4'-7 4, SECTION 'B-B'
C PROPOSED ELEVATION VIEW
IWNCR NCR SelfSery 88ATM Site Preparation Datasheet (6006-6921-6000)
Drive -Up version with CEN Security Enclosure.
This Site Preparation Datasheet is to be used in conjunction with the following documents:
NCR SelfSery 88 ATM Site Preparation (B006-6586)
NCR SelfSery 88 Installation Guide (13006-6590)
NCR SelfSery 32, 34 and 88ATMs Site Preparation Requirements (13006-6670)
ATM DIMENSIONS
1412 mm
(55.59 in.)
_ 1046 mm
(41.18 in.)
including bumper
702 mm
(27.64 in.)
1040 mm
(40.94 in.)
Package Dimensions
ATM and Pallet
ATM, Pallet and Carton
Height
1702 mm (67.0 in.)
1836 mm (72.3 in.)
Width
977 mm (38.5 in.)
Length
140.5 mm (55.3 in.)
Floor Loading uL
CEN Grade L
Maximum weight 990 kg
1075 kg
(2183 lb.)
(2371 lb.)
Floor loading 1268 kg/m2
_
1377 kg/m2
(260lb.fftI)
(2821b.fft2)
E ATM MANUFACTURER DETAILS
NOTE: FOR ADDITIONAL STRUCTURAL DETAILS & STRUCTURAL STAMP SEE ATTACHED MANUFACTURER DRAWINGS
D I ISLAND DETAILS
ENVIRONMENTAL REQUIREMENTS
Temperature and Humidity
Normal Operating Range
Interior Environment
Exterior Environment
Lobby &
Through -the -Wall
Freestanding
Through the Wall ATMs
ATMs
Drive -Up ATMs
Without air conditioning
Temperature
100C to 400C
-35°C to 50°C
-35°C to 45°C
(-317 to 113°F)
(dry bulb)
(507 to 1047
(-31°F to 1227)
With air conditioning
See Note 1.
See Note 3.
-350C to 500C
(-317 to 122°F)
Relative
20% to 80%
10% to 100%
10% to 100%
humidity
See Note 2.
See Note 3.
Dew point
temperature
26°C (79°F) max.
26°C (797) max.
26°C (79°F) max.
restriction
Note 1: If severe environment is fitted, the minimum temperature is 0°C (32°F).
Note 2: For Through the Wall ATMs, the humidity inside the building is restricted to a
maximum of 30% at an outside temperature of -35°C (-317), with a linear
relationship between temperature and humidity to a maximurn humidity at 0°C (327).
Note 3: If a passbook printer is fitted, the minimum exten or temperature is 0°C (327) and
the maximum relative humidity is 80%.
ATM installation through an extehDrwall must meet the requirements of both the
Interior and Exterior (through the wall) environments.
Storage Range
Transit Range
Extreme Power On Range
(Up To Three Months)
(Up To One Week)
(Up To One Hour)
Temperature
-10°C to 50°C
-40o C to 600C
0°C to 45°C
(14 F to 122 F)
(-40 F to 140°F)
(32°F to 1137)
Relative
Humidity
10% to 90%
5% to 95%
10% to 95%.
Barometric Pressure
Operating and transit limits 105 kPa (15.2 lb. F/in.) to 70 kPa (10.2 lb. F/in.)
Equivalent altitude Up to a maximum of 3000 m (9842.52 ft).
PHYSICAL SECURITY
POWER REQUIREMENTS
Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely
or sporadically. When such phenomena occur, the use of protective devices may be required
to ensure proper operation of the equipment.
AC Power Requirements
The maximum current. requirements at the stated input voltages are:
• 10A at 120V
• 6.3A at 230V
The maximum inrush current is 100A
Input Voltage Setting
The ATM can operate from the following input mains voltages:
• 90V to 136V at 50,160Hz
• 180V to 264V at 50/60Hz.
Power Cable
The ATM is supplied either as a 120V or a 220-240V unit.
120V ATMs are supplied with a power cable fitted with a NEMA type 5-15P power source connecto
220-240VATMs are supplied with an unterminated power cable.
Information about suitable power connectors is supplied with the accessories.
The power cable supplied is 3 rm (9.8 ft) in length. If it is necessary to increase this length
to meet site requirements, then the extension must satsfy local or country regulations.
WARNING
This equipment must be grounded (earthed)
Grounding Requirements
The ATM operates from a single phase, 3 wire supply- live, neutral and ground.
The power requirements of this unit will normally permit it to operate within existing
wiring configurations and from existing branch mains outlets providing:
1. Where the supply is provided from a general purpose distribution panel, then the other
branch circuits from this panel must not be used to support heavy inductive loads such
as air conditioners, elevators, Microwave ovens, and so on. Nor may such equipment
be operated on the same branch circuit as the ATM.
2. If using distribution panels, all branch circuit grounding conductors must be
connected to an insulated terminal strip in the distribution panel. The grounding
conductor from the distribution panel to the building ground point must be at least
equal in size to the power conductor necessary to supply the NCR system.
Note: The building ground point can affect data integrty.
For additional information, refer to the Data Line Transient Protection section in the
publication 'NCR SelfSery 32, 34 and 38ATMs Site Preparation Requirements'.
THE SECURITY SAFE MEETS THE BANK PROTECTION ACT B2 STAT 295,
12 USC 882, A.ND MEETS THE ATTACK TEST PER UL 291-15- THE SAFE DOOR
HAS A POSITIVE RELOCKING FEATURE. THE SAFE DOOR IS CONTROLLED BY A
GROUP 2 COMBINATION LOCK WITH OR '44fITHOUT KEYLOCKING DIAL CAPABILITY
OR OPTIONAL ELECTRONIC LOCK.
ALARM PROTECTION
THE UL-LISTED SAFE IS EQUIPPED WITH A BASIC ALARM SENSOR PACKAGE. THE
BASIC PACKAGE INCLUDES A SAFE DOOR OPEN SNITCH, ALARM SHUNTING SWITCH,
AND RATE -OF -RISE HEAT SENSOR,
INSTALLER TO DRILL (4) 3/4" DIAMETER HOLES TO BE DRILLED
INTO THE CONCRETE ISLAND. ATM TO BE SECURED TO THE
CONCRETE ISLAND WITH (4) 3 4" UNC X 6 1/4" WEDGE ANCHORS.
BOLT INSTALLATION
F I BOLLARD DETAILS
APPR
PLAW;,4 wu'
City of Federal Way
Dept. of Community Developmi -
Permi _05 Z l_u
B
Date
0
w^J
v /
O
M
W �^
O
='
J
Q
nQLU
z
�
o
®w
C)
�
�
C)
Q
�
z
w
UJ-Jw
Q
z
Lu
.
C�
W
I--
z
w
CU
zz
M�
W
0-
0
p
M
V
^
00
cr)
V J
r/1
Vj "J
Q
LL
Q
._I
C i
Q
W
—'
o
W
to
I—
O
N
W
DRAWN:
A.RIOS
JOB:
TWIN LAKES
SCALE:
NOTED
DATE:
08/13/2018
REV
7.000"
4.937"
a
Io
72. 000"
55.000"
Ltd
r
co
7.000"
4,937"
G I ATM ENCLOSURE SPECIFICATIONS (FOR REFERENCE ONLY)
(4) 1 " BOLTS
BY OTHERS
(4) #4 VERT -
2'-O"
PIVOTING CLEARANCE
B,AR $Y OTHERS
9,
BACK OF
CURB
Q�
FOUNDATION DETAIL
1 /2"=1 °-O"
I. THI5 FOUNDATION 15 M516NED TO BE USED WITH A PIVOTIN6
CLEARANCE BAR BY UNI-STRUCTURES INC. 8540 COBS CENTER
DRIVE 5TE 100 KENNE5AW 6A 50152
2. THE EN61MM-RS STAMP ON THIS PAGE 15 FOR THE FOUNDATION
ONLY. THE PIVOTING BAR AND ANCHOR BOLTS ARE BY OTHERS.
Ltd. t W"
DE51 GN CRITERIA
TH15 FOUNDATION HAS BEEN DESIGNED TO MEET THE FOLLOWING CRITERIA:
SNOW LOAD
50 P5F
WIND SPEED
150 MPH
SEISMIC COEFF
ISA WORST CASE
MAX. IMPACT FORCE
650LBS @ Y ABOVE ANCHORS
ANY USE OF THIS DRAWING FOR A LOCATION OTHER THAN THE LOCATION
INDICATED BELOW 15 PROHIBITED AND WILL MAKE THESE DRAWINGS INVALID.
GENERAL NOTES:
1. CONSTRUCTION SHALL CONFORM TO THE LATEST STATE BUILDIN6 CODE.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, PROPERTY LINES,
ETC. ON THE .JOB.
FOUNDATION5:
I. EXCAVATION5 SHALL BE CLEANED OF ALL DEBRIS. STANDING WATER
SHALL BE REMOVED.
2. FOUNDATIONS DESIGNED USING THE FOLLOWING VALUES FROM 2004 IBC
TABLE 1806.2:
ALLOWABLE PRESSURE: 1500 P5F
PIER LATERAL BEARING: 100 PSFx2*=200 PSF/FT OF DEPTH
*INCREA5E ALLOYED PER 1506.5.4.
GONGRETE 4 RE I NEORCf I NG 5TEEL:
I. CONCRETE CON5TRUCTION SHALL CONFORM TO ACI 5I5-08.
2. THE MIN 26 DAY 5TRENGTH 4 TYPE OF CONCRETE SHALL BE AS FOLLOWS:
FOUNDATIONS 3000 PSI (150 PCF)
H VHD "VERTICAL HEIGHT DETECTOR" SPECIFICATIONS
00
0
N
SEE
A
I Of 2
Ln
cn
7 00011 +
72.00Q"
55.000"
LOAD
i NYLON
N END
TUBE TO PREVENT
VG TUBE
ADS
NOTE TO INSTALLERS:
INSTALL (3) CARRIAGE BOLTS
FROM BOTTOM-UP(AS SHOWN)
3" X 5" ACCESS TO
ELECTRICAL
ON BACKSIDE OF PYLON
POLE COVED..._-_
TO MOUNT OVER BOLTS
CONCRETE nBFLOYILCURB
INTRACTOR:
'LON HEIGHT 9'-0" ACCORDING TO CLEARANCE,
GRADE TO BOTTOM OF CANOPY, YOU WILL NEED TO ADJUST THE
HEIGHT OF THE CAGE TO CORRECTLY CALCULATE THE DISTANCE BETWEEN THE TWO.
THERE MUST BE AT LEAST 3. OF BOLT THREAD ABOVE THE BASE PLATE -
RA A790
i
,7 0"
Left Side Mew
T-1
—6
16" CENTER OF PLATE
~ TO BACK OF CURB
Cn
LOOP UNDER PAVEMENT
1
FOUR (4) J-BOLT ANCHOR '
SUPPORTS WELDED, ASTM. A307
CAGE SUPPLIED BY US[
9'-0"
JRB
�1---*h;
PLANNI,
City of Federal Nay
.Dept. of Community Development
Permit to ' vi Vf __rr
3
17,qfP_ VU
o
00
N
rn
`n
�
w
w
Q
U
LO
¢
Zw
X
=cz
0.�
Q
LL
®�
cz
cj
N
�
OLLI
C3
�
N
L,
w
U
O
0 Ne
v
rr
W
ry-
W
::D
C
i
U
a
QU)
or
LL
W
D
Q
z
z
�--
W
Q
LiJ
CD
2
c
Ir
W
f--
z
W
U
Zz
Q
-
m
�
OO
co
c)
_
0
Ir Q
Cl)
�
a
W
VJ
J
Z
�
Q
W
—
(/)CC
ow
o
N
LL
DRAWN:
A.RIOS
JOB:
TWIN LAKES
SCALE:
NOTED
DATE:
08/13/2018
REV
2
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
220 Automatic Teller Machines and Fare Machines
220.1 General. Where automatic teller machines or self-service fare vending, collection, or adjustment machines are provided, at
least one of each type provided at each location shall comply with 707. Where bins are provided for envelopes, waste paper, or
other purposes, at least one of each type shall comply with 811.
308 Reach Ranges
308.1 General. Reach ranges shall comply with 308.
308.2 Forward Reach.
308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm)
maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or ground.
308.2.2 Obstructed High Reach. Where a high forward reach is over an obstruction, the clear floor space shall extend beneath
the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48
inches (1220 mm) maximum where the reach depth is 20 inches (510 mm) maximum. Where the reach depth exceeds 20
inches (510 mm), the high forward reach shall be 44 inches (1120 mm) maximum and the reach depth shall be 25 inches
(635 mm) maximum.
308.3 Side Reach.
308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side reach is
unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380
mm) minimum above the finish floor or ground.
EXCEPTIONS:
1. An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the
obstruction is 10 inches (255 mm) maximum.
2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface
of the vehicular way where fuel dispensers are installed on existing curbs
308.3.2 Obstructed High Reach. Where a clear floor or ground space allows a parallel approach to an element and the high side
reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and the depth of the
obstruction shall be 24 inches (610 mm) maximum. The high side reach shall be 48 inches (1220 mm) maximum for a reach
depth of 10 inches (255 mm) maximum. Where the reach depth exceeds 10 inches (255 mm), the high side reach shall be 46
inches (1170 mm) maximum for a reach depth of 24 inches (610 mm) maximum.
309 Operable Parts
309.1 General. Operable parts shall comply with 309.
309.4 Operation. Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of
the wrist. The force required to activate operable parts shall be 5 pounds (22.2 N) maximum.
707 Automatic Teller Machines and Fare Machines
707.1 General. Automatic teller machines and fare machines shall comply with 707.
707.2 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided.
EXCEPTION: Clear floor or ground space shall not be required at drive -up only automatic teller machines and fare machines.
707.3 Operable Parts. Operable parts shall comply with 309. Unless a clear or correct key is provided, each operable part shall
be able to be differentiated by sound or touch, without activation.
EXCEPTION: Drive -up only automatic teller machines and fare machines shall not be required to comply with 309.2 and 309.3.
707.4 Privacy. Automatic teller machines shall provide the opportunity for the same degree of privacy of input and output
- I ACCESSIBLE SPECIFICATIONS
available to all individuals.
707.5 Speech Output. Machines shall be speech enabled. Operating instructions and orientation, visible transaction prompts, user
input verification, error messages, and all displayed information for full use shall be accessible to and independently usable by
individuals with vision impairments. Speech shall be delivered through a mechanism that is readily available to all users, including
but not limited to, an industry standard connector or a telephone handset. Speech shall be recorded or digitized human, or
synthesized.
EXCEPTIONS:
1. Audible tones shall be permitted instead of speech for visible output that is not displayed for security purposes, including but
not limited to, asterisks representing personal identification numbers.
2. Advertisements and other similar information shall not be required to be audible unless they convey information that can be
used in the transaction being conducted.
3. Where speech synthesis cannot be supported, dynamic alphabetic output shall not be required to be audible.
707.5.1 User Control. Speech shall be capable of being repeated or interrupted. Volume control shall be provided for the
speech function.
EXCEPTION: Speech output for any single function shall be permitted to be automatically interrupted when a transaction is
selected.
707.5.2 Receipts. Where receipts are provided, speech output devices shall provide audible balance inquiry information, error
messages, and all other information on the printed receipt necessary to complete or verify the transaction.
EXCEPTIONS:
1. Machine location, date and time of transaction, customer account number, and the machine identifier shall not be
required to be audible.
2. Information on printed receipts that duplicates information available on -screen shall not be required to be presented in
the form of an audible receipt.
3. Printed copies of bank statements and checks shall not be required to be audible.
707.6 Input. Input devices shall comply with 707.6.
707.6.1 Input Controls. At least one tactilely discernible input control shall be provided for each function. Where provided, key
surfaces not on active areas of display screens, shall be raised above surrounding surfaces. Where membrane keys are the
only method of input, each shall be tactilely discernable from surrounding surfaces and adjacent keys.
707.6.2 Numeric Keys. Numeric keys shall be arranged in a 12-key ascending or descending telephone keypad layout. The
number five key shall be tactilely distinct from the other keys.
707.6.3 Function Keys. Function keys shall comply with 707.6.3.
707.6.3.1 Contrast. Function keys shall contrast visually from background surfaces. Characters and symbols on key
surfaces shall contrast visually from key surfaces. Visual contrast shall be either light -on -dark or dark -on -light.
EXCEPTION: Tactile symbols required by 707.6.3.2 shall not be required to comply with 707.6.3.1.
707.6.3.2 Tactile Symbols. Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised
circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised plus sign; Decrease
Value key: raised minus sign.
707.7 Display Screen. The display screen shall comply with 707.7.
EXCEPTION: Drive -up only automatic teller machines and fare machines shall not be required to comply with 707.7.1.
707.7.2 Characters. Characters displayed on the screen shall be in a sans serif font. Characters shall be 3/16 inch (4.8
mm) high minimum based on the uppercase letter "I". Characters shall contrast with their background with either light
characters on a dark background or dark characters on a light background.
707.8 Braille Instructions. Braille instructions for initiating the speech mode shall be provided. Braille shall comply with 703.3.
BRAILLE DIMENSIONS
DOT BASE DIAMETER
DISTANCE BETWEEN 2 DOTS
IN THE SAME CELL
DISTANCE BETWEEN
CORRESPONDING DOTS IN
ADJACENT CELLS
DOT HEIGHT
DISTANCE BETWEEN CORRESPONDING
DOTS FROM ONE CELL DIRECTLY BELOW
.059-.063
.090-.100
.241-.300
.025-.037
.395-.400
ATM BRAILLE DECALS
REMOVE STATEMENT
. . ... . . .. .. .
• • • • • • • • • • • •
INSERT CARD
REMOVE CASH
DEPOSIT CHECKS
DRIVE THRU ATM IS EXEMPT FROM SECTION 707.2 (REF: 305). CLEAR FLOOR SPACE & GROUND SPACE.
DRIVE THRU ATM IS EXEMPT FROM SECTION 707.3 (REF: 309.2 & 309.3). OPERABLE REACH.
DRIVE THRU ATM MEETS SECTION 707.3 (REF: 309.4). OPERABLE PARTS.
DRIVE THRU ATM MEETS SECTION 707.4. PRIVACY.
DRIVE THRU ATM MEETS SECTION 707.5. SPEECH OUTPUT.
DRIVE THRU ATM MEETS SECTION 707.6. INPUT.
DRIVE THRU ATM S EXEMPT FROM SECTION 707.7.1. DISPLAY SCREEN. APPROVEL)l
DRIVE THRU ATM MEETS SECTION 707.7.2. DISPLAY CHARACTERS PLANNING
DRIVE THRU ATM MEETS SECTION 707.8. BRAILLE INSTRUCTIONS. City of Federal Way
Dept. of Community Development
Permit#
,.U�-2Z
Vw
Z
Zw
Fr
w
x
w
a
J
Q
O C7
w
c�
cc o
w
0 O
Z
Y
r n U)
V ♦ -
W Q
O W
Z r)
W W
J J
coW W
r
-n n
rU)
v/ CrU)
//
W W
U U
U U
Q Q
W
Z
W
CU
ZZ
Ma-
W CL
00
rr
vJ
� se
W
VJ
J
•-� Z
W
F-
o LO
00 ,
N OD
(3)
U
a
= x
CU CZ
C u_
Q
N
CO 00
J N
LO
> a7
O d
U r
O �
W N
0
0
N
00
0)
Q
07
f- Q
CM
J
� W
O t)
N LL
DRAWN:
A.RIOS
JOB:
TWIN LAKES
SCALE:
NOTED
DATE:
08/13/2018
REV
D3
OF 8
3/4"C
(2) #10 THWN (ATM)
(1) #12 THWN GRND (ATM)
(2) #12 THWN (ENCLOSURE)
(1) #12 THWN GRND (ENCLOSURE)
1 I ELECTRICAL PLAN
�— 3/4" C
(2) #12 THWN
(1) #12 THWN
H}
=>WOO
3
VERTICAL TIES
CLOSED TIES
PIER SECTION
25'-0" MAX HEIGHT
OF LIGHT POLE
WITH COVEDR OLE /—TO REBAR IN FOOTING
GROUND LUG W/ #8 G CU
(4) 3/4"Ox30"x3" EMBED
(MIN) A307 ANCHOR BOLTS W/
LEVEL'G NUTS & WASHERS AT
EHEX ENDS -ARRANGE TEMPLATE
PER LIGHT POLE MFG. SPECS
-BOLTS MUST BE SPACED ON
A 8" BOLT CIRCLE MIN.
CD CV
1 112" NON -SHRINK
GROUT UNDER BASE
4'E
(3) #3 CLOSED TIES W/ 1350
BENDS W/ IN TOP 6" OF PIERS
GROUND LUG
(4) #5 VERT. BARS GRADE 40
W/ 900 BENDS & 8" MIN
- TAILS
X .
- #3 CLOSED TIES W/ 135°
BENDS SPACED C) 12" O.C.
FULL DEPTH
c�
3/4"0 CONDUIT
24 (2) #10 THHN
(1) #10 THHN GRND
LIGHT STANDARD BASE
31 LIGHT POLE SPECIFICATIONS
NEW ATM
PS4-11-20 D2
Project:
Prepared By:
Lamp Info
Type:
Wafts-
Shape/Size:
Base-
1q0
ANSI:
Hours:
Square steel poles drilled for 2Area Lights at 180". Designed for ground
Lumens -
mounting. Poles are stocked nationwide for quick shipment- Protective LarT� Lumens_
packaging ensures poles arrive at the job site good as new_ Efficacy
Color: Bronze Weight 137.0 Ibs
Technical Specifications
Listings weight:
CSA Listed: 137 lbs.
Suitable for wet locations. Gauge:
Construction 11
Shaft: wall Thickness:
46,000 p.s.i, minimum yield. 1/8"-
Hand Holes: S haft Size:
Reinforced with grounding lug and removable 4'_
cover.
Hand Hole Dimensions:
Base Plates:
3' x 5".
Slotted base plates 36,000 p_s.i.
Bolt Circle:
Shipping Protection:
8 1 /2" _
All poles are shipped in individual corrugated
cartons to prevent finish damage. Base Dimension:
Color: 8"
Bronze powder coating.
Height:
20 FT.
4 I LIGHT STANDARD BASE
Type:
Date:
Ballast Info
N/A Type:
OW 12OV_
N/A 208V:
N/A 24OV:
WA 2TTV:
N/A Input Watts:
WA
N/A
Anchor Bolt:
1 "C
6 THWN
HWN GRND
WA
WA
WA
WA
WA
OW
Galvanized anchor bolts and galvanized
hardware and anchor bolt template. All bolts
have a 3" hook.
Anchor Bolt Templates:
WARNING Template must be printed on I I" x
17" sheet for actual size_ CHECK SCALE
BEFORE USING. Templates shipped with
anchor bolts and available.
Pre -Shipped Anchor Bolts:
Bolts can be pre -shipped upon request for
additional freight charge.
MaxEPA's/Max weights:
70MPH 8.3 ft f240 lb
80MPH 5.6ft 11651b
90MPH 3.6ft /1101b
100MPH 22 ft /75 lb
11 OMPH LO ft_/45 lb
120MPH 02 ft 120 lb -
Other
Terms of Sate:
Pole Terms of Sale is available
Buy American Act Compliance:
RAB values USA manufacturing! Upon
request, RAB may be able to manufacture this
product to be ccmpliant with the Buy American
Ad (BAA)_ Please contact customer service to
request a quote for the product to be made
BAA compliant_
U EXISTING
UTILITY SERVICE
1 "C
(2) #6 THWN
(1) #10 THWN GRND
3/4"C
(2) #12 THWN
(1) #12 THWN GRND
I I
M I 3/4"C
I (2) #10 THWN
(1) #12 THWN GRND
I 20A I
20A
I 30A i
PEDESTAL
208V/120V
100A
NEW 'ATM' NEW 'ENCLOSURE' NEW 'LIGHTING'
120-208 30AMP 120-208 20AMP 120-208 20AMP
SCALE: 1/8'1 = 1'-01, 1 21 SINGLE LINE DIAGRAM
PS4-11-20 D2
Dimensions
20'
18'
FI
Features
Designed for ground mounting
HeavydutyTGIC polyester coating
Reinforced hand holes with grounding lug and removable
cover for easy wiring access
Anchor Bolt Kit includes pole cap and base cover (sold
separately)
Custom manufactured for each application
Type: Date:
r't•,
Job Name:
Contractor:
or
Catalog No.:
Orbit Induratriem, Inc.
Notes:
LFL8 Series - 15OW
Descriptions
The LFL8 Series are powerful LED Area Lights ideal for outdoor applications such as
exterior building righting, roadways, loading docks, or parking areas. Compared to
traditional area lighting, the slim design of these Ultra -Bright LED Area Lights makes them
lighter in weight, easier to install. Unlike other Area Lights, the LFL8 can be mounted and
wired without having to access inside the fixture making the installation process even
faster. Motion Sensor optional. UL listed for Wet Locations. DLC Premium Listed.
General Specifications
so,)
Input Voltage 120-277V LFL8-SF LFL8-T LFL8-PM LFL8-YK
Electrical Input Power 150W *Mounting options (sold separately)
_..------- ---------- ,
Power Factor > 0.9 i Dimensions
Light
Output
Total Lumens
Efficacy
- CRI
Color Temp..
_ BUG _
Distribution Type:
Equivalent':
205821m
m
e
riousingi AUl 1L Ule _aST Aluminum A x B x C:
Finish. UV Resistant Bronze Powder Coat 15OW: 11" x 11-3/8" " x 3-112
Finish Photometrics
High Light Transmittance Physical Lens Material I 6 5 4 isoto«cr t
3 2 9 e 1. z J 5
- -
Polycarbonate Lens
__ House Side
AmbientOperating Templ -40*C/ 40°Fto_40*C/_104*F5
Mount (Sold Separately) Slip Fitter, Trunnion, =.3
Yoke, Post Mount z
Other Certification cULus E335594, DLC Premium T eI�
__-- — yp
I — r — ; -- ---
Type II ---
------------------ -_,_---
► Lifespan: 50,000 hrs ► Accessories (Sold Separately): =TypeIIl
-- .s
i 3 Ty�Iy--------
--------------------
Motion
► Beam Angle: W x 120° Sensor: llAAAS-R 4
► Warranty: 5 Year Limited Warranty Remote Control: MI11lS-RC 5 stYeIt SI& g
6
El 20 fc 2.5 f� 0.2 fk
► Dimmable to 10% .IOfc ■rfc 0.1 fc Total UP: 0.69
■ 5 k 0.5 k ■ 50% Max Cd
C �L r Dsta Ke n units of mount hei*t (20ft) --- Max Cd
► UL listed for Wet Location
MMS-R MMS-RC PHILiPS 1
L_ U M I L E D S IP65 IItIIIYS LM79
Item No. DescriPibn Std. Pkg.
LFL8-15OW-H LFL8 SLIM LED AREA LIGHT HOUSING ONLY, 15OW 120--277V 5000K-BRONZE 1
LFL8-SF SUP FITTER FOR LFL8 SERIES 5
LFL8-T TRUNNION MOUNT FOR LFL8 SERIES t0
LFL8-PM POST MOUNT FOR LFL8 SERIES 8
LFL8-YK-80 YOKE MOUNT FOR LFL8 8OW-150W 1 Q
.� a "a
AF hU,
U.S.A. ®1-800-90-oRBlr * www.orbit 1 4 ,1
51 LIGHT FIXTURE SPE
City of Federal Way
CD
00
N
LO
to
CO
Uz
Q
U
LO
d1
I11
Z IA
X
I_
N
T
x
a }
— _
Q
CU
'�
N
Oo
J
N
LO
�W
>
o
U
d
/�
Vz
o
°'
W
0)
a-
`W
1
Z
W
U
z
Z
-
%<
W
O
O
CM
!�
t.J
N
O
00
M
�^
V1 1 IJ
Q
Q
�
co
J
z_
Q
W
Oo
�
3:
F--
N
II
DRAWN:
A.RIOS
JOB:
TWIN LAKES
SCALE:
NOTED
DATE:
08/13/2018
REV
El
,F 8
Date 2 ` -ZO
"A" Style 16" Metered Commercial Pedestal
HINGED
DEMAND
METER
RESET
COVER
WITH
WINDOW
REMOVEABLE
TEST BYPASS
•
0
BLOCK COVER
•
(1F APPLICABLE)
PRINT
POCKET
0---7
Iu
�
OO
0
PADLOCK
BRACKET
EXTENDS
THROUGH
42OF
DOOR
FOR
n
n
n
�
SECURITY
n
HINGED EXTERIOR DOOR
WITH DOOR STOP TO HOLD
DOOR IN OPEN POSITION
HINGED
DEADFRONT
CPA 6PDMNT-CALT
MOUNTING BASE
�' I FULLY HINGED
METER SECTION
COVER
4
I
I
I
I
I
I
I
I
1
1
r77r
CP-16PDMNT-CALT
MOUNTING BASE
PHOTO CELL WINDOW
WITH SHIELD
(IF APPLICABLE) 1li3fPOP
15,
�+14112`
I 13'
1 If
UTILITY
SECTION
14 112' 9 V4'
16' 12114� CUSTOMER
215" UTILITY
TERMINATION
LANDING MIN.
- --- !- 7
—7�+
:9. . _
+(.:
LIFT-OFF
SERVICE ANCHOR BOLT
COVER MOUNTING HOLES
PEDESTAL
MOUNTING HOLES
3` RECOMMENDED MIN.
FOUNDATION EXTENSION
ALL SIDES. 6' REC.
Pad Mount Base or (4) 5/8-11 X 18" Anchor Bolts Recommended
61 UTILITY PEDESTAL SPECIFICATIONS
Catalog Number: 120/240 VAC, 1-phase, 3-wire; 100 Amps Maximum, (see Main circuit breaker rating)
Rainproof - Type 3R, Steel (G90) Enclosure, painted MINT GREEN
CP31351119A42SP9 Enclosed Industrial Control - Suitable ONLY for Use as Service Equipment
The short circuit current rating is 42,000 RMS symmetrical amperes maximum at 240volts maximum, in
accordance with the table below, but is limited to the lowest short circuit rating of any installed circuit
breaker. Watthour meter is not included in the short circuit rating. Replacement circuit breakers must
be of the same type and rating.
11ACTCDc;n r`It7f I IIT niQF_r`TnPv
No.
Amp.
Poles
Circuit Description
No.
Amp.
Poles
Circuit Description
1
3
100
2
Main
2
THIS SPACE NOT AVAILABLE
4
THIS SPACE NOT AVAILABLE
5
30
1
ATM-1
6
THIS SPACE NOT AVAILABLE
7
20
1
ATM-2
8
THIS SPACE NOT AVAILABLE
9
20
1
AB-244-1
10
THIS SPACE NOT AVAILABLE
11
20
1
AB-244-2
12
THIS SPACE NOT AVAILABLE
13
20
1
1 AB-244-3
14
THIS SPACE NOT AVAILABLE
15
20
1
AB-244A
16
THIS SPACE NOT AVAILABLE
17
20
1
General Use 1 (Siemens Type: QPF)
18
THIS SPACE NOT AVAILABLE
I
20
1
General Use 2 (Siemens Types QPF)
20
THIS SPACE NOT AVAILABLE
21
20
1
22
THIS SPACE NOT AVAILABLE
23
20
1
24
THIS SPACE NOT AVAILABLE
AIC RATING
MAIN
BRANCHES
MILBANK TYPE MOP; SIEMENS
MILBANK TYPE: MQP; SIEMENS TYPE: QP (1-POLE 70A
10
TYPE QP; CUTLER HAMMER TYPE
MAX), QT, QPF; CUTLER -HAMMER TYPE: BR, QFCB, HQP,
HQP, BR; GE TYPE THQL
QPGF; GE TYPE TQL, THQL, THQL-GF
MILBANK TYPE MQPH; SIEMENS
MILBANK TYPE: MQPH; SIEMENS TYPE: QPH (1-POLE
22
TYPE QPH; CUTLER HAMMER TYPE
70A MAX), QPHF; CUTLER -HAMMER TYPE: BRH, QPHW,
QPHW, BRH; GE TYPE THHQL
QPHGF; GE TYPE THHQL, THHQL-GF
SIEMENS QPH
SIEMENS TYPE: QP (1-POLE 70A MAX), CT, QPF
22
SERIES
CUTLER HAMMER TYPE QPHW
CUTLER HAMMER TYPE HQP, QPGF
RATED
GE TYPE THHQL
GE TYPE THQL
SIEMENS TYPE HQP; CUTLER
SIEMENS TYPE: HQP (1-POLE 70A MAX); CUTLER -
42
HAMMER TYPE QHPX
HAMMER TYPE: QHPX
42
SIEMENS TYPE: QP (1-POLE 70A MAX), QPH, QT, QPF,
SERIES
SIEMENS HQP
QPHF
RATED
Terminal Information. Use AUCU conductors
FIELD WIRED CONNECTORS
BUS CONNECTIONS
For Equipment Ground ONLY,
multiple conductors in a single
opening are pennissable as
indicated bebw
SLOTTED HEAD SCREWS
THREADFORMING SCREWS
Socket
q
AWG
To ue
Lb: In.
Tor q
AWG
W1e
Small
Large
SCREW
MATL
Lb -InIn..
Se
Lbr-Itn�.
Size
Hole
Hole
Wire
Size
Small
Hole
Large
Hole
5116.
275
#14-10
20
35
10-24
AL
30
#14-10
1-2
1-2
vs8
375
#8
25
40
10-24
CU
50
IIT
500
#6
35
45
1/120
AL
50
#10
1
3
9/16"
600
#4
-
45
1/r20
CU
72
N-6
1
1
#3-1/0
-
50
#4 - 1/0
1
Sheet 1 of 2
IN U.S.A.
Circuit breaker handle trip
position is between "ON" and
"OFF". To reset breaker, move
handle to the full "OFF" position,
then to full "ON".
Shipping may loosen electrical connections. CHECK TIGHTNESS BEFORE
ENERGIZING.
BONDED NEUTRAL — Remove neutral load conductors for test purposes only!
FIELD INSTALLED conductors shall be 60°C, 75°C, or 90°C, sized to 60°C
rating for 110 amps or less; and 75°C or 90°C for 125 amps and above.
MIMILBANIC
Catalog Number:
CP3B51119A42SP9
Meter Socket
200 Amps Continuous
(1009722)
CAUTION:
Lever By-pass.
Circuit may W
_
We with meter
removed. Meter
is bypassed
I
when handle is
M2
rotated upward.
—MI
A G B
0_ 0',
0" -
OA N OB
Service Termination
Section (1114904)
MADE IN U.S.A.
W MIN,
CLRANCE
MOUNTING BASE DETAIL REQUIRED PER
N.E..0 11&1(D'
TYPICAL
FRONT & BACK
ENCLOSURE
DEPTH
120/240 VAC, 1-phase, 3-wire; 100 Amps Maximum, (see Main circuit breaker rating)
Rainproof -Type 3R, Steel (G90) Enclosure, painted MINT GREEN
Enclosed Industrial Control - Suitable ONLY for Use as Service Equipment
Nlal ITI 11 NINI I
CD
rfl X X X X X X X X X X X X
0
20 Amp G
Class CC Fuse
(1124484) 0 D
17 1
0o
5.20
(1047334)
N G
20 Amp
V Class CC Fuse o
.o (1124484) O O
p 19 1
N - 5-20
(1047334)
N N1
• •••()••• • • o
I (1047063) SERVICE _
GROUND
CUSTOMER BARRIERED SECTION
I I
I I II
I I
o
U
} I
W I
Q
W
I �
Q_
I I
I
I
I I
I
I I
I
II
I
Sheet 2 of 2
CP3B1 1519ASP16
SIDE VIEW
18 of Top
(457mm)
UTILITY TERMINATION
LANDING.
LIFT OFF SERVICE
I I
COVER +h9TH HANDLE.
I I CUSTOMER
PADLOCKABLE.
! SECTION
1<
SERVICE
23
TERM
SECTION I
(584mm)
I
PADLOCK
I
I I
I I
j
BRACKET
j
GRADE
3" (76mm)
RECOMMENDED MINIMUM
FOUNDATION EXTENSION
ALL SIDES
67 (152mm)
RECOMMENDED MINIMUM
FOUNDATION DEPTH BELOW
GRADE LEVEL.
36" (914mm) MINIMUM
PEDESTAL CLEARANCE
TYPICAL FRONT AND
BACK REQUIRED PER
N.E.C. 110-16.
(4) 5/8-11 X 18
(450mrn 16UNC)
ANCHOR BOLTS
RECOMMENDED.
(Place r, rpper
rat corner of
customer section)
SERVICE
GROUND
PnMILBANK7
TYPICAL CONSTRUCTION &
INSTALLATION DETAILS
PADLOCK BR)
EXTENDS THR
DOOR FOR SE(
HINGED DEADF
HINGED EXTERIO
MEANS PROME
HOLD DOOR IA
POSITION
BASE
RECOMMENDED M(
BASE ENCLOSI
CONCRETE
CONCRETE
FOUNDATION
SERVICE
CONDUIT —
MOUNTING BASE DETAIL
(TOP VIEW)
❑ SERVICE
TERMINATION
UNE SECTION/416
F(24
(406mrn)
CUSTOMERm)
SECTION
141/2
LO(366mm)
GROUND ROD
13
(330mm)
14 1/2
(Were
15
(381mm)
16
(406mm)
O PEDESTAL MOUNTING HOLES
❑ ANCHOR BOLT MOUNTING HOLES
FRONT
VIEW
16
(406mm)�
D
JITS
?OD WITH
CLAMP
120"
3000mm)
OPTIONAL
NO BASE, MOUNT
MOUNTING
FOUNDATION.
DIRECTLY ON
3 (76mm)
I
•, 6' (152mm) Minimum
jl;
But should encase
anchor bolts
' : I
I • 71
' 17minimum
•:�
I - ::�
�..: e'. for CP-ABK5/8
`a 1
APPROVED
PLANNING
..City, of Federal Way
Dept. of Community Development
Permittl M'_1 q71- V A
o
00
N
0)
LO
,
r
0z
U
1
LO
d
w
Z Lu
X
E
O
-O
r
X
a. }
a
LCLZ
_ _
CZ
OD
OD
.J
N
L0
w
J
?�
CD
i
O
U
0)
d
0z
o
T
w
o
C:
CL
W
Z
W
UR
Z
Z
CL
0
0
M
00
V J
VJ
Q
WU.
Q
v,
J
Z
�
�
Q
W
_
�
C)
o0
rr
co
Uj
IL
DRAWN:
A.RIOS
JOB:
TWIN LAKES
SCALE:
NOTED
DATE:
08/13/2018
REV