23-104612City of Federal Way
pr.
FIL F
• Community Development Dept
33325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
Project Name: BRADBURY
Project Address: 30438 2ND AVE S
Project Description: Installation of standby generator
Electrical
Permit #:23-104612-00-EL
Inspection Request Line: (253) 835-3050
Parcel Number: 339190 0140
Owner
Applicant •
Contractor
JULIE A BRADBURY
COREY GiLGANWASHINGTON
WASHINGTON GENERATORS LLC
30438 2ND AVE S
GENERATORS LLC
(ELECTRICAL)
FEDERAL WAY WA 98003-4001
8901 S 228TH ST BLDG F
WASHIGL7956N (8/23/25)
KENT WA 98031
14404 SE 216TH ST
KENT WA 98042
Is this an Online or O.T.C. application?........
Alt. Serv./Feeder: 0 to 200 aml 1
Additional Permit Information
Yes
Electrical Fixtures
CONDITIONS:
A permanently installed generator is not allowed to be placed within required yards (setbacks). See
Bulletin #150 for placement details.
PERMIT EXPIRES Tuesday, 12 March, 2024
Permit Issued on Thursday, September 14, 2023
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way.
Owner or agent: ONI INIF Date:
u
CITY OF
Federal Way
THIS CARD IS TO REILAII ON -SITE
Construction Inspection Record
INSPECTION REQL"ESTS. (253) 335-3050
Scheduled inspections ma%: be failed if this card is not on -site. DO NOT LOSE TBIS CARD. L+ispections are listed as close to sequential order as possible
(read left to right. top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you a_Te utnsuTe about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card.
ELECTRICAL
Q
L TR Ground (4295)
Q
Ditch corer (4030)
El
Slab/Concrete Floor (4255)
Approved
Approved
approved to place concrete
By
Date
By
Date
By
Date
Q
Pool Bonding (4195)
Temporary Power (4275)
0
Service (4235)
Approved
Approved
Approved
By
Date
By
Date
By
Date
0
FeederslSub-panels (4045)
Q
Rough Electrical (4225)
0
Ceiling Cover (4020)
Approved
Approved
Approved
B-v
Date
Bj•
Date
By
Date
E]
Final - Electrical (4055)
Approved
By
Dated
MECHANICAL
t❑
Mechanical Rough -in (416)
Gas Piping (4125)
Q
Final - Mechanical (4065)
Approved
Approved to release test
Approved
By
Date
By
Date
By
Date
PLUMBING
0
Plumbing Groundwork (4190)
Rough Plumbing (4230)
❑
Final - Plumbing (4075)
Approved to cover
Approved
Approved
By
Date
By
Date
By
Date