21-104684City of Federal Way Community Development Dept, 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 i ILEBuilding - Single Family Permit #:21-104684-00-SF Inspection Request Line: (253) 835-3050 Project Name: BARCELO HOMES LOT 2 Project Address: 3818 S 326TH ST Parcel Number: 152104 9224 Project Description: BLUEBEAM - Construction of new 2-story single family residence with a 210 square foot covered entry, 229 square foot deck and a 636 square foot attached garage. Includes plumbing and mechanical. Owner Applicant Contractor Lender BARCELO DEVELOPMENT INC NADIA MAKSIMCHUKBARCELO BARCELO DEVELOPMENT INC OWNER IS LENDER PO BOX 1639 HOMES PO BOX 1639 MERCER ISLAND WA 98040 PO BOX 1639 MERCER ISLAND WA 98040 MERCER ISLAND WA 98040 Census Category: 101 - New Single Family House Includes: # 1 #2 #3 #4 Occupancy Class: R-3 U Construction Type: Type V- B Type V- B Occupancy Load: Floor Area (sq. ft.) 1 4,058.00 1 636.00 Additional Permit Information New / Additional Sq. Feet - I st Floor ..................... 2012 New / Additional Sq. Feet - 2nd Floor..................., 2046 New / Additional Sq. Feet - 3rd Floor ..................... 0 Occupancy # 1 - Area (Sq. Feet)............................ 4058 New / Additional Sq. Feet - Basement .................... 0 Basic Plan?........................................................... No Occupancy # 1 -Construction Type ......................... Type V - B New / Additional Sq. Feet - Deck.......::........:......... 229 New / Additional Sq. Feet - Garage ........................ 636 Mechanical to be Included? ............................... Yes Plumbing Work Valuation? ................ I ............... . 15000 Mechanical Work Valuation?.............. 18000 Number of Stories ................................................... 2 Occupancy #2 - Class.............................................. U New / Additional Sq. Feet - Other ............................ 210 Plumbing to be Included?........................................ Yes New / Additional Sq. Feet - Total ......................... 5133 Will Certificate of Occupancy be Issued?............... Yes Occupancy # 1 - Use .............. Residence (1 or 2 Comprehensive Plan Designation................:.:.. ... SF - High -Density family) Residential Zoning Designation.....:.:...... ,. RS 9.6 Total Valuation: 541,462.43 Mechanical Fixtures Air Handling Units 1 Fans Plumbing Fixtures Bathtubs 3 Dishwashers Lavatories 8 Showers Water Closets 5 Water Heaters Fire conditions: Fire sprinklers are required. No framing inspection until the sprinkler CONDITIO t is installed and 8 Fireplace Inserts l� 1 Laundry Washer Outlets 1 2 Sinks 2 1 Hose Bibbs 3 roved. PERMIT EXPIRES Wednesday, 8 February, 2023 Permit Issued on Friday, August 12, 2022 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will rdance with the laws, rules and regulati jnR&IIHM, of Wa t d th `.City of Federal Way JAN 15 7M Owner or agent: City of Federal Way Certificate of Occupancy Date: This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: BARCELO HOMES LOT 2 Address: 3818 S 326TH ST Permit # 21-104684-00-SF Includes: #1 #2 #3 #4 Occupancy Class: R-3 U Construction Type: Type V - B Type V - B Occupancy Load: Floor Area (sq. ft.) 4,058.00 636.00 Owner Name: BARCELO DEVELOPMENT INC Owner Address: PO BOX 1639 MERCER ISLAND WA 98040 NIT I;�- K Building Official 2.1-71Zoz¢ Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/ or occupant of the premises. THIS CARD IS TO REMAIN ON -SITE , crr?or- Construction Inspection Record • Federal Way INSPECTION REQUESTS: (253) 835-3050 1, PERMIT #: 21 104684 00 'Address: 3818 S 326TH ST Project: BARCELO DEVELOPMENT INC FEDERAL WAY WA 98003 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. 0 SWM Precon Site Mtg (4400) 2❑ Site Assessment (Erosion) (4365) 3❑ Footings/Setback (4110) Approved To be done PRIOR to breaking ground Approved to place concrete By Date By Date By 41J Date 0 Foundation Wall (4115) Q Drainage/Downspout (4040) Q Plumbing Groundwork (4190) Approved to place concrete Approved to backfill Approved to cover . By Date -2 )4 y By Date I 2���-�% By Date ❑ Slab/Concrete Floor (4255) 0 Underfloor Framing (4285)❑ Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By Date 6 '" By PA Date 1fl Shear Walls (4245) 11 Roof Sheathing (4220) 12 Rough Plumbing (4230) By Approved to install siding Date By Approved to install rooling' Date By Approved Date tj3 +3 Mechanical Rough -in (4165) l] Gas Piping (4125) I] Fire/Draft Stops (4095) By Approved Date By Approved to release test A+ Date 0715 By Approved Date 16 By Interim Erosion Control (4370) Approved Date Prior to scheduling a Framing inspection; Electrical, Plumbing & Mechanical Rough -in and Fire/Draft Stop inspections must be signed - off and approved. IBC 109.3.4 17 By Framing (4120) Approved to insulate Q Date dL 0 Insulation (4150) 19 Gypsum Wallboard Nailing (4130) 20 Final Erosion Control (4375) rd Approved to install wallre" Approved to install mud & tape Approved By Date 1� �,3 By Date By Date Final - Mechanical (4065) 22 Final - Plumbing (4075) Final - Building (4050) By I1nnnn'' Approved ( Date Byig Approved Date 7-12IP4_ ByOk Approved Date 1 Z� pwl t/ Oz-4- Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date 1�CITY OF Federal Way • Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: 38�sa S 3u'� S i'kRTy11T#: ZI - l o+(9$4--w CD Cli tjC3'QiL 3�— 5ow c-avzri_ tz_34z.> L c__ 1.1 lk-, S t G tJ A W Yf-� r-{?-Q w` k4 p. C, C3 (J ' — C- T cTrcMS Fes- f �6 IF YOU HAVE QUESTIONS CALL &kc4— (253) 835- 26Z1 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. Z41IL11k: 4 DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of r CITY OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, 98-6325 V:k:�Phone 253-835-2607 Faxx 253-835835-2609 CORRECTION NOTICE ADDRESS: -�,Gt S 3'L-4 i'^ si PERMIT#: _ ZI - 104&M -00 L-o T L etZO S LO" C6 L-- G�Y►nrl P t t� i j S t C4►J" 6yr Z �.k.; C �� S v c F�►� rkv s t Gj-j C' F cjJ S LTE- C6KF1r- C-, CFI LtryJ $ �h- Pc Ft 1519 Sn�.�c..#� Fu,�t-r•��E� D 1� ��R— Dv�1GTs l�(o t z I C huc" ►.L6ii��5 N['i_ q__ A-w-AZ-64— �c.7� 7� 0 yz-- r Z 03 , N�sU � Pr-3`un-� ��.•[-il �t,c..l�--�,c�1 e-n� �y?`P� E Grx--- gy- OCGu PAZt - c7-r-'s LlNg_ IZ t ob'. i P-r i)t:. I 1=1 P F Si fie. 0 "0— Lc,N E_ TO rw_ C*V -tom [ IJ k at— C*V W— Li o,*/ ✓O w t I-0— (2— PM- C, AYL_ Ste- CA-A- ti, 0 1 ZO WAX04 P&Tti CrO_ t 3Ct'' SOLAD C 0 ,f- tSZltrYL VJ SSL4-- Ctoa L t* t�-t c-LuStA s) U6,d1 1�-w l,,,c ] c-zw E- 51;-� z gnat 000mtJ �nn� 1aW�V--FA31_U_ yj1 - t4ft LAAN "IO a — ��BRt�S i lYr �1 XZ 4,09, `S) C!"r— Rem%' D4, cc. IF YOU HAVE QUESTIONS CALL . oc�c (253) 835- 24Z� WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. 1 17,& 1 Z. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of CITY OF Building Division �. Federal Way'33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: S8(5 e-- Qai PERMIT#: Zl — I C)+(o 5+ -Oct 1PLy wkt3E t,� '0" W* +, fbt3,<- M. vb l rn'ot- (X) t NS"f"_1t_ tioT Lens ir_- AL wr_�d4*14mK.. P"V , P L_ VJ5 i — bvc-T' C-kA_t€ cc_f_ 'Tgj;6.-i ?VZavt Fr i [7-t 0-r- w PAZW, A LI A D1zP� i-N Fwt_ vV *,Prr tA-M �cc-�cL �� wS S4- 20l'$ VJO-4L- C.dre �i— IF YOU HAVE QUESTIONS CALL '► Gkf__ (253) 835- 24 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. IJS ji-4- my - DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of d ADDRESS: CITY OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, x 98003-6325 y Phone 253-835-2607 Fax 253-35-609 CORRECTION NOTICE -:; S ft 3 l' ` 7-- G*L -- PERMIT#: Z! - [ C) 4-& !64 -Cc) �� � S c.. �- W � tZ � t ra � r ✓�1 �S i �c [:''— TU i'� :� : S 1{�a w � � 2— i�>C2-y LA_ —FI) �r �l�Str0 ✓L- [Tec 1I-72 Vt— r Ii�LI� lvf L fa 51�� W IZ� V4, v b + Zl!��Yec c_ u5 er . f [ =' ��S2uvt .• ; . - Cr. .� � `I F[- c�-;� -- ; c}�= l,'� ifc � Z - z [ (4 �� O r-J UAL 1J L/KAt?,CfA l z w i�r�T IDS 5 Lfs C, J—� V') IF YOU HAVE QUESTIONS CALL (253) 835- 7'� 2 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. lS' 1-)-4-- vt'(c� DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of TO SCHEDULE OR CANCEL AN INSPECTION, OR TO OBTAIN INSPECTION RESULTS CALL: (253) 835-3050 Be prepared to provide: 10-Digit Permit Number 4-Digit Inspection Code (see below) Preferred Date of Inspection Phone Number where you can be reached between 7:00 and 4:00 o You will receive a confirmation number at the end of the call. Make a note of the number for reference if a problem occurs with scheduling. If you do not receive a confirmation number, the inspection was not successfully scheduled. o The correct inspection code must be used to schedule, cancel or obtain inspection results. The system will only accept codes that are associated with your permit. Please verify that the inspection is included on the card attached to the permit before attempting to schedule. o Every effort will be made to perform inspections on the requested day, but it may take up to 48 hours, depending on workload. INSPECTIONS WILL NOT BE PERFORMED (AND YOU MAY BE ASSESSED REINSPECTION FEES) IF: o The work is not complete and ready to be inspected o Approved site copy of permit/plans/inspection card are not on site, available to inspector o Site address is not clearly posted o Inspector does not have access to the site or project. It is the responsibility of whoever is requesting an inspection to provide any special equipment —such as ladders —required to access any aspect of the project. BUILDING INSPECTIONS ELECTRICAL INSPECTIONS Drainage/Downspout/Footing 4040 Ceiling Cover 4020 Fire Stopping/Draft Stops 4095 Ditch Cover 4030 Floor Sheathing 4105 Feeders/Sub-Panels 4045 Footing/Setbacks 4110 Final Electrical 4055 Foundation Wall 4115 Pool Bonding 4295 Framing 4120 Rough Electrical 4225 Gypsum Wallboard Nailing 4130 Service 4235 Insulation 4150 Temporary Power 4275 Reinforcing Steel 4215 -Roof Sheathing 4220 SIGN INSPECTIONS Shear Walls 4245 Attachment 4010 Slab/Concrete Floor 4255 Final Sign 4085 Suspended Ceiling Grid 4265 Final Electrical for Signage 4055 Under -floor Framing 4285 Footing/Setback 4110 Under -Slab Groundwork 4295 FINAL INSPECTIONS MANUFACTURED HOME INSPECTIONS Building 4050 Blocking /Tie Downs 4015 Final SWM 4375 Skirting/Final 4250 Fire Department call (253) 946-7318 to schedule Planning call project planner to schedule SURFACE WATER MANAGEMENT INSPECTIONS Public Works call project inspector to schedule Temp Erosion/Sediment Control 4365 Final SWM 4375 MECHANICAL INSPECTIONS PLUMBING INSPECTIONS Final Mechanical 4065 Final Plumbing 4075 Gas Piping 4125 Plumbing Groundwork 4190 Mechanical Rough -In 4165 Rough Plumbing 4230 Page l' of 1 �.;.Krazan&Associates,lnc_ Geotechnical Engineering . Environmental Engineering Construction Testing and Inspection DATE: 9/19/2023 Field Report NO.: 06623338DFR9192023 RH-1 Set Count: 1 CONTRACTOR: PROJECT #: 06623338 PERMIT #: PROJECT: Barcelo Homes Residence 1NSPECTOR: Randy Hansen LOCATION: 3828 SW 326°i Street JURISDICTION: Federal Way KA P.M.: WBT WEATHER: Mostly Cloudy TEMP: On site as requested by the contractor for the following: Proprietm Anchor Inspection Observed the client install (6) 5/8 threaded rod anchors into 8" deep holes that were cleaned by brush and compressed air at the Northwest corner of the structure for the added window that was in the first level pantry. The bolts were set in place with Simpson Set-XP Epoxy. The work was performed in accordance with plans, specifications, engineer fix, and installation instructions. Reviewed By: I ASTM Test #: Asset Number(s): To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use ofthe client. This report may not be rcpnxluwA in w). forms[ nitlutul the v.7ittca permissAna afthc Ocat and Kr R Associalcs. This mpon indices ourinspectors observation and testing results based on site conditions and contrsctoractivities Tbi%infuMTAIen is subjoct In mvicw poor to Goal abMiuol. By signing this tcpon. our inspector does not acccA responsibility for validity of results. The same information has been provided by others on site. The test results apply only to the specific locations, and items inspected or tested Template date 4/20/2023 ADDRESS: CITY OF Federal Way' Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE PERMIT#: 1 TR( � aa !.� Ch e Q��Ivti �'� :.� fV Jac< 165 ace- Y10 1 k -n CSA `4A r �t IF YOU HAVE QUESTIONS CALL ! (253) 835 39 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DAi INSPECTOR EEO NOT REMOVE THIS NOTICE Page of Andrew Norton From: Andrew Norton Sent: Thursday, August 31, 2023 7:00 AM To: 'hakamseattle@gmail.com' Cc: Andrew Norton Subject: 21-104684 Truss bracing missing on A2,3,4,5,6,7,8 Complete LS50 clips per details 17/19 page A3 " On North facing balloon framed wall plan calls for 3 — 2x6 trimmers Complete gable bracing per detail QS4 A Complete blocking per detail 20/A3 Complete details 2,3/S4 for shear wall transfer to trusses ! SW 1 missing upstairs Hold down nuts loose throughout Plan calls for DF 6x6 posts for all HD8 and HD11 Add plate strap and stud in bedroom 2 on south wail OR to approve shearwall modification in pantry, window added Missing blocking in balloon walls per note on page A7 FOR to approve drilled holes in PSL beams on lower floor ECCQ's missing in garage LVL 6x6 missing for front porch ridge beam support per plan �6. Add web stiffener per detail 8/S4 More corrections may follow at the next inspection. Andrew Norton Plans Examiner City of Federal Way 253-835-2639 CITY OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, 98003-6325 y Phone 253-835-2607 Faxx 253=835835-2609 CORRECTION NOTICE ADDRESS: _ PERMIT#: 2 ) e %0 PL • 1 W V Bch 4t- W�!Ajffi T're.nkc kla!t +15A1%! . _T r ,. IF YOU HAVE QUESTIONS CALL Aia (253) 835- 21,e 39 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253)r835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of _ CITY OF Building Division � Federal Way'33325 Eighth Avenue South Federal Way, WA 9$003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE fo ADDRESS:. C] - � I , PERMIT#: IF YOU HAVE QUESTIONS CALL -ere (253) 835- 2 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. "J ATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of CITY OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, 98003-6325 Phone 253-835-2607 Fox 253-8,�5-2609 CORRECTION NOTICE ADDRESS: PERMIT#: 21 -'� 7 D 'e' 11 T IF YOU HAVE QUESTIONS CALL A �� � (253) 835- Z % 3 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. ATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of