21-101150-PlanSet-01-27-2022-V2DRAWING SHEET INDEX
PERMIT SUBMIt
POST PERMIT
ARCHITECTURAL:
A0.1
GENERAL PROJECT INFORMATION
9 AUG 2021
27 JAN 2022
A0.2
ENERGY CODE COMPLIANCE
9 AUG 2021
27 JAN 2022
A0.3
SITE PLAN
9 AUG 2021
27 JAN 2022
A1.1
DEMO PLANS
9 AUG 2021
27 JAN 2022
A2.1
BASEMENT PLAN
9 AUG 2021
27 JAN 2022
A2.2
MAIN FLOOR PLAN
9 AUG 2021
27 JAN 2022
A2.3
UPPER FLOOR PLAN
9 AUG 2021
27 JAN 2022
A2.4
ROOF PLAN
9 AUG 2021
27 JAN 2022
A3.1
EXTERIOR ELEVATIONS
9 AUG 2021
27 JAN 2022
A4.1
BUILDING SECTIONS
9 AUG 2021
27 JAN 2022
A4.2
BUILDING SECTIONS
9 AUG 2021
27 JAN 2022
A9.1
SCHEDULES
9 AUG 2021
27 JAN 2022
STRUCTURAL:
S1.0
STRUCTURAL NOTES AND DETAILS
3 JUN 2021
27 JAN 2022
S2.0
MAIN FLOOR FRAMING
9 AUG 2021
27 JAN 2022
S3.0
UPPER FLOOR & ROOF FRAMING
9 AUG 2021
27 JAN 2022
BUILDING CODE HIGHLIGHTS
SECTION
TITLE
SUB -SECTION
HIGHLIGHT
CONSTRUCTION TYPE
V-B
FIRE SPRINKLERS
NONE REQUIRED, NONE PROVIDED
FIRE ALARMS
NONE REQUIRED, NONE PROVIDED
NOTE: ---
UTILITY INFORMATION
UTILITY
REMARK
ELECTRIC
EXISTING 200AMP ELECTRICAL PANEL IN BASEMENT. GC TO DETERMINE IF IT
NEEDS TO BE EXPANDED TO ACCOMMODATE NEW CIRCUITS FOR REMODELED
KITCHEN AND BATHROOMS.
GAS
EXISTING METER AT EAST TO REMAIN.
STORM
NO WORK.
WATER
EXISTING WATER SUPPLY ASSUMED TO BE SUFFICIENT.
SEWER
EXISTING SEPTIC SYSTEM ASSUMED TO BE IN SATISFACTORY CONDITION.
NOTE: ---
VICINITY MAP
PROJECT LOCATION
Puget
���
:.
-,
_.:•I..
Wirrzanita
a
4
1Zc: nllr} I
N
�
�t
W E
x
v 2$6tll it
A &�FlI
3 path sr -.
d
x
Ks
J•
- SW 330th g!
7: •h Lnlh
._ 72r]If,
Dash Flolrtt v
_ rI
�a rn `t
�i ��i�� ral
i!+
£
-t..
Wav
=
L,
nL
5'ti'
]i nlh 51 w I•
-. li- � �•. I'I I ti
���.
•I'I II"I
J
++ 1!.In
01
= c`
_ry -�cth 5t
��y S • �_I � .
+f - S5kll "M1
Algona
ITT, 15t A7P5
5 Ain rl
Idl+l' wl W
T'''i
i ❑
Pacific
matoll
APPLICABLE CODES
YEAR
TITLE
2021
FEDERAL WAY REVISED CODE, TITLE 19 (ZONING)
* Intemational 8ufid ng Code 08Q, 2018 edition, including Appendices E and J
• Washington State Amendments, WAC 51-50 and RCW 19.27 & 70.92
• Access i bi 1 ity Code I CC/ANSI A117.1-2009
* International Residential Code (IRQ, 2018 edition, including Appendices H &j and excIuding chapters I anal 25
through 43
o Washington State Amendments, WAC 51-11 R, 5 1 -5and 296-46B
* Intemationa! Mechanical Code (IMQ 2018 edit!an
o Washington State Amendments, WAC 51-52 and RCW 19.27
* International Fire Code (I F)r 2018 edition, including Appendices Bf Cr E, F, and
o Washington State Amendments, WAC 51-54A and RCW 19.27
* International Ex sVng Bfiildinrg Code (IEBC, 2018 edition
* International Poet & Gas Code (IFGQ 2019 edition•
* International Property Maintenance Code (IPMQ 2018 edition
* International Energy Conservation Code (I ECC), 2019 edition
o Washington State Amendments}, WAC 51-11 R & 51-11 C and RCW 19.27
��} �}
* Washington State Energy Code (WSEQ, 018 edition
* (rational Electrical Code (NEQr 2020 edition
Washington State Amendments, WAC 296A3, 6-45 & 96-46B and RCW 19.28
* Om form Plumbing Code (U PC), 2018 edition, excluding chapters 12 and 15
Washington State Amendments, WAC 51-56 and RCW 19.27
City of Federal Way
Building Division
REVIEWED FOR CODE COMPLIANCE
Date: 02/14/2022
Approved By: GKirk
GENERAL PROJECT INFORMATION
ITEM
REMARK
EXISTING USE
SINGLE-FAMILY RESIDENTIAL
PROJECT
REMODEL OF EXISTING KITCHEN AND 3 EXISTING BATHROOMS AND
DESCRIPTION
MISCELLANEOUS INTERIOR WORK. ADDITIONAL 16 SF TO BE ADDED
T L 0 I RIOR. ONE NEW WINDOW AT EXTERIOR.
CITY PROJECT #
21-101150
OCCUPANCY
_'U
PROPERTY
30845 50th PL SW
ADDRESS
FEDERAL WAY, WA, 98023
PARCEL #
112103-9047
LOT SIZE
24,396 SF (PER KING CO ASSESSOR)
BEG AT SW COR GL 4 TH N 00-30-00 E ALG W LN 1071.98 FT TO
STONE MONUMENT DESIGN COR A TH N 00-30-00 E 60.42 FT TO MDR
COR BET SEC 10 & 11 TH ALG GOV MDR LN N 20-00-00 E 300 FT TO
LEGAL
TPOB TH SELY 95 FT M/L TO PT N 29-51-20 E 300 FT FIR COR A TH S
DESCRIPTION
19-54-50 E 453.6 FT TH N 36-57-30 E 69 FT TH N 22-24-30 W 448.52 FT
TH NWLY 101.40 FT M/L TO PT ON GOV MDR LN N 20-00-00 E 50 FT FIR
TPOB TH S 20-00-00 W 50 FT TO TPOB & TD LDS 2ND CL TO EXTREME
LOW TD ADJ
QUARTER -SECTION-
TOWNSHIP -RANGE
NW-11-21-3
NEIGHBORHOOD
DASH POINT
ZONED
RS-35
ECA
YES
1. MASTER PLAN SCOPE (MAIN FLOOR):
-REMODEL KITCHEN COMPLETE
-REMOVE TWO WINDOWS AND REPLACE GLASS DOOR WITH WINDOW AT KITCHEN
-NEW FRONT DOOR
-LIGHTING AT ENTRY, DINING & LIVING
-PATCH WOOD FLOORING NEXT TO KITCHEN & FRONT DOOR
-REMOVE EXISTING POST AT GRID B / 3, & REPLACE WITH NEW BEAM ALONG GRID B
-RELOCATE DOOR FROM INTERIOR TO GARAGE
-REMODEL GUEST BATHROOM COMPLETE
-NEW WINDOW AT GUEST BATHROOM
-CREATE NEW LAUNDRY ROOM
-NEW LIGHTING AT ABOVE ROOMS
-NEW POST AT GRID A.6 / 3.3 & NEW BEAM ABOVE ALONG GRID 3.3
2. MASTER PLAN SCOPE (UPPER FLOOR):
-REMODEL CHILD BATHROOM COMPLETE
-ENLARGE FLOOR AREA AT MASTER BATHROOM NORTH BY 16 SQUARE FEET
-REMODEL MASTER BATHROOM COMPLETE
-REPLACE CEILINGS IN ALL ROOMS EXCEPT FLEX ROOM
-NEW INSULATION AT UNDERSIDE OF ROOF SHEATHING, IF MISSING
-NEW FLOORING THROUGHOUT SECOND FLOOR
-REPLACE INTERIOR DOORS THROUGHOUT SECOND FLOOR
3. MASTER PLAN SCOPE (BASEMENT FLOOR):
-NEW FILTER BOX & FRESH -AIR DUCT AT EXISTING FURNACE
-NEW ON -DEMAND WATER HEATER
-NEW POSTS & FOOTINGS TO SUPPORT NEW GRID B BEAM AT UPPER FLOOR
-POSSIBLY UPGRADE ELECTRICAL PANEL IF NOT ENOUGH CIRCUITS AVAILABLE
(PROJECT CONTACTS
n►nIti s= a
DAWN McCAUSLAND & HOAN TRAN
30845 50TH PLACE SW
FEDERAL WAY, WA, 98023
CONTACT: DAWN
(510) 967-6157
DAWNFMM@GMAIL.COM
eRru1TE=rT -
VELOCIPEDE architects inc
3104 WESTERN AVENUE #102
SEATTLE, WA 98121
CONTACT: GEORGE OSTROW
(206) 529-9356
GEORGE@VELOCIPEDE.NET
STRUCTURAL:
O.G. ENGINEERING, PLLC
8645 22ND AVE SW
SEATTLE, WA 98106
CONTACT: OWEN GOULD
(206) 290-4608
OWEN@OGENGINEER.COM
GENERAL CONTRACTOR:
SOCKEYE HOMES
14638 SE 229TH PLACE
KENT, WA 98042
CONTACT: ROBERT NEWMAN
(425) 737-4456
RNEWMAN@SOCKEYEHOMES.COM
VELOCMEDE
3104 Western Avenue #102
Seattle WA 98122
REGISTERED
ARCHITECT
GEONE OMOW
STATE OF WASHINGTON
RESUBMITTED
1/31/2022
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
c�
3
Al 27 JAN 2022
DATE: 9 AUG 2021
PHASE: POST PERMIT
PROJECT: 2009
DRAWN: JWN
SCALE:
GENERAL
PROJECT
INFORMATION
251
AO-1
VELOCTEDE
Alterations Worksheet - 2018 Washington State Energy Code
Project Information Contact Information
30845 50TH PLACE SW
DAWN McCAUSLAND (OWNER)
30845 50TH PLACE SW, FEDERAL WAY WA 98023
510-967-6175
The WSEC requirements for alterations are located in Chapter 5 of the code text.
Alterations (remodels) do not need to obtain energy credits from Table R406.3
Additions must meet the requirements for new construction. This includes nonconditioned space being
altered to become conditioned space.
Will the wall cavities be exposed? v Yes No
If yes: Exposed wall cavities must be insulated -
2 X 4 wall studs require R-15 insulation
2 X 6 wall studs require R-21 insulation
Will the roof/ceiling framing cavities or attic be exposed? , Yes
ZITS
If yes: Exposed roof/ceiling assemblies must be insulated -
Vaulted ceilings: Insulate to the full depth of the framing member
while allowing for the minimum 1" ventilated space
Flat ceilings
Will the floor framing cavities be exposed?
Install R-49 insulation or what the attic space can
accommodate based on the roof pitch
Yes
If yes: Exposed floor cavities must be insulated to R-30
M
Are the windows and/or doors being replaced? -o Yes No
(includes both window or door and frames)
If yes: New windows and doors must have an area weighted average U-factor of <_0.30
Will the heating or cooling system be replaced? Yes v No
If yes: New equipment must meet current requirements and
ducts need to be tested
Will the hot water system be altered? � Yes
If yes: New water heating equipment must meet current code requirements
Are more than 50% of the light fixtures being changed? Fv- Yes
If yes: 75% of all lamps must be high efficacy 1
(LED or CFL)
No
R503.1.1 Building envelope. Building envelope assemblies that are part of the alteration shall comply with Section R402.1.1
or R402.1.4, Sections R402.2.1 through R402.2.11, R402.3.1, R402.3.2, R402.4.3 and R402.4.4.
Exception: The following alterations need not comply with the requirements for new construction provided the
energy use of the building is not increased:
1. Storm windows installed over existing fenestration.
2. Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled with
insulation. 2x4 framed walls shall be insulated to a minimum of R-15 and 2x6 framed walls shall be insulated to a
minimum of R-21.
3. Construction where the existing roof, wall or floor cavity is not exposed.
4. Roof recover.
5. Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing
shall be insulated either above or below the sheathing.
6. Surface -applied window film installed on existing single pane fenestration assemblies to reduce solar heat
gain provided the code does not require the glazing fenestration to be replaced
R503.1.1.1 Replacement fenestration. Where some or all of an existing fenestration unit is replaced with a new
fenestration product, including sash and glazing, the replacement fenestration unit shall meet the applicable requirements
for U -factor and SHGC in Table R402.1.1. Where more than one replacement fenestration unit is being installed, an area -
weighted average of the U-factor and SHGC of all replacement fenestration shall be permitted to be used to demonstrate
compliance.
R503.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the
alteration shall comply with Section R403.
Exceptions:
1. Where ducts from an existing heating and cooling system are extended, duct systems with less than 40 linear feet in
unconditioned spaces shall not be required to be tested in accordance with Section R403.2.2.
2. Existing duct systems constructed, insulated or sealed with asbestos.
R502.1.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the addition shall comply
with Section R403.
Exception: The following need not comply with the testing requirements of Section R403.3.3:
1. Additions of less than 750 square feet.
2. Duct systems that are documented to have been previously sealed as confirmed through field verification
and diagnostic testing in accordance with procedures in WSU RS-33.
3. Ducts with less than 40 linear feet in unconditioned spaces.
4. Existing duct systems constructed, insulated or sealed with asbestos.
R503.1.3 Service hot water systems. New service hot water systems that are part of the alteration shall comply with
Section R403.5.
R503.1.4 Lighting. New lighting systems that are part of the alteration shall comply with Section R404.1.
Exception: Alterations that replace less than 50 percent of the luminaires in a space, provided that such
alterations do not increase the installed interior lighting power.
R503.2 Change in space conditioning. Any nonconditioned or low -energy space that is altered to become conditioned space
shall be required to be brought into full compliance with this code.
Propertyaddress: -------------------------------------------------- --------
Builder/registered design professional name: --------------------------- --- ----
Builder/reg. design pro. signature: ---------------------------------------------
Conditioned floor area: ftz (per building permit)
R-Values R303.1.1
' Ceiling/ Vaulted R------- Floors: Over unconditioned space R-_____
Attic:
Attic R--- ------- Slab -on -grade floor R-___
Walls: Above grade R Fully insulated slab? Y/N (Circle one)
Below, int. R Doors: R------, R------- R--- --
Below, ext. R.......
U-Value of Windows, Skylights and Doors (R303.1.1.3)
Average area weighted U-value from Glazing Worksheet Average U- -
Fuel Normalization (Tables R406.2) and Energy Credits (Table R406.3)
System Type Number (1 to 5) (Select one)
Energy Credits selected (1 to 7)
Fuel Normalization Credit + Total Energy Credits _______ = Total Credits ______-
Heating, Cooling and Domestic Hot Water
System Type (Manufacturer and Model Number
Efficiency
Heating
Cooling
DHW
Drain water heat
recovery
Onsite Renewable Energy Electric Power System
" System type ______________________ _____ System design capacity __________ kW
Rated annual generation _____________________ kWh/yr
Appliances
Energy Star?
Manufacturer and Model
(Circle one)
Dish washer
Y or N
Refrigerator
Y or N
Washer
Y or N
Dryer
Y or N
Vented or unvented? If vented, CEF rating
Gas fireplace / heating stove (Section R402.4.2) Fireplace efficiency (FE)
Heating or Decorative? (Circle one)
AVAILABLE AT:
www.energy.wsu.edu/Documents/Compliance%20Certificate%202018%20WSEC.pdf
HVAC System Duct Leakage Testing (R403.3)
Circle one
All ductwork and air handler in conditioned space? (See Option 4.2) Y or N
All ductwork in unconditioned spaces buried and tested at 3% total leakage, and air Y or N
handler in conditioned space? (See Option 4.1.)
All ductwork & air handler outside conditioned space insulated to minimum R-8? Y or N
Air handler present at duct leakage test? (Total leakage 4% if yes, 3% if no) Y or N
HVAC leakage to outside test conducted at final? Y or N
Do HVAC duct leakage tests include GPS and time stamp verification? Y or N
HVAC system leakage test calculated design target: CFM @ 25 Pa
HVAC system leakage test measured results: CFM @ 25 Pa
Building Leakage Testing (R402.4.1.2)
Dwelling unit leakage test calculated design target: -------------- ACH @ 50 Pa
Dwelling unit leakage test, measured results: ACH @ 50 Pa
Whole Building Leakage test (R2 corridor only) design target: CFM/sf @ 50 Pa
Whole Building Leakage test (R2 corridor only) measured: CFM/sf @ 50 Pa
Do building leakage tests include GPS and time stamp verification? Y or N
Whole House Ventilation System Measured Flow Rates (M1505.4 IRC-WA)
Circle one
Are the system controls correctly labeled? Y or N
The Whole House Ventilation (WHV) system operation and maintenance (O&M) Y or N
instructions were provided to the building owner?
Provided to: on (date)
--------------------
Whole House Ventilation System Type: (Circle one)
(1) Whole house exhaust fan, location
(2) Balanced HRV/ ERV, location
For R2 low-rise, serves more than one unit? Y or N
(3) Supply or HRV WHV integral to the air handler. Describe system control sequence of
operations or reference to design submittal:
---------------------------------------------------------------
Specify run-time: _______ hours per day _______________ CFM
WHV calculated design minimum flow rate per plan submittal:
WHV measured min flow rate at commissioning: Exhaust ________CFM, Supply _______CFM
Do WHV flow tests include GPS & time stamp verification? Y or N
HRV/ERV sensible heat recovery efficiency: -----------
Commissioning Notes:
Other Mandatory Requirements
Circle one
All other mandatory requirements of WSEC-R have been met?
Y or N
INSTRUCTIONS:
www.energy.wsu.edu/Documents/Compliance%20Certificate%201nstructions%202018%20WSEC_rev%2012-9-20.pdf
ENERGY COMPLIANCE
PER 2018 WASHINGTON STATE ENERGY CODE, MARINE 4
ITEM
REQUIRED
PROVIDED
SECTION
NEW WINDOWS
U-0.30
U-0.30
TABLE R402.1.1
NEW SKYLIGHTS
U-0.50
(NONE IN PROJECT)
TABLE R402.1.1
NEW OPAQUE
DOORS
U-0.30 (FIRST 24 SF EXEMPT)
U-0.30 (FIRST 24 SF EXEMPT)
SECTION R402.3.4
NEW SLABS
(UNHEATED)
R-10 (2 FT AT PERIMETER)
(NONE IN PROJECT)
TABLE R402.1.1
NEW FLOORS
R-30
(NONE IN PROJECT)
TABLE R402.1.1
NEW WALLS
R-21
(NONE IN PROJECT)
TABLE R402.1.1
EXPOSED
EXISTING 2x4
WALLS
R-15
R-15
(HIGH -DENSITY FIBERGLASS
BATTS)
R503.1.1(2)
NEW HEADERS
R-10
R-10
TABLE R402.1.1
NEW WALLS
BELOW GRADE
R-13 + R-5 CONTINUOUS
(INTERIOR)
(NONE IN PROJECT)
TABLE R402.1.1
EXPOSED
CEILINGS
R-38
R-38 (9" FIBERGLASS BATTS) + R-12
MINIMUM EXTERIOR RIGID
INSULATION
TABLE R402.1.1
INSULATION
CERTIFICATE
PER WSEC R401.3, PRIOR TO FINAL INSPECTION, THE BUILDER SHALL COMPLETE AND POST
THE INSULATION CERTIFICATE (ON THIS PAGE) WITHIN 36" OF THE ELECTRICAL PANEL
PRIMARY SPACE
HEATING
EQUIPMENT
SPLIT -SYSTEM HEAT PUMP
(E) SPLIT -SYSTEM HEAT PUMP
SECTION R403.7.1
HEATING DESIGN
LOAD
MIN: ---
MAX: ---
---
SECTION R403.7
SPACE HEATING
DUCT INSULATION
R-8 (IF OUTSIDE)
R-8 (LOCATED IN BASEMENT)
SECTION R403.3.1
PRIMARY SPACE
HEATING
CONTROLS
PROGRAMMABLE
PROGRAMMABLE
SECTION R403.1.1
WATER HEATING
EQUIPMENT
DOE 10 CFR PART 30
(N) GAS ON -DEMAND TANKLESS
SECTION R403.5.1
WATER PIPING
R-3
R-3
SECTION R403.5.3
90% CFL / LED
90% CFL / LED
SECTION R404.1
LIGHTING
PER WSEC R404.1: A MINIMUM OF 90% OF PERMANENTLY INSTALLED LAMPS IN LIGHTING
FIXTURES SHALL BE HIGH -EFFICACY LAMPS
VENTILATION
---
---
---
AIR LEAKAGE
(NOT REQUIRED IF NO ADDITIONS)
SECTION R402.4.1.2
DUCT LEAKAGE
4.0 CFM 25 / 100 FT
4.0 CFM 25 / 100 FT
SECTION R403.3.4
WINDOW LEAKAGE
0.3 CFM / FT
0.3 CFM / FT
SECTION R402.4.3
ADDITIONAL
---
---
SECTION R406.2
CREDITS
(NOT REQUIRED WHERE NO NEW SQUARE -FOOTAGE IS ADDED)
NOTE:
��`
3104 Western Avenue #102
Seattle WA 981121
REGISTERED
ARCHITECT
GEONE OSiROW
STATE OF WASHINGTON
RESUBMITTED
1/31/2022
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
Al 27 JAN 2022
DATE: 9 AUG 2021
PHASE: POST PERMIT
PROJECT: 2009
DRAWN: JWN
SCALE: 1/8" = F-0"
ENERGY
CODE
COMPLIANCE
AO-2
1
J
LOT COVERAGE CALCULATION
EXISTING
NEW
TOTAL LOT
COVERAGE
LOT SIZE (KING CO)
24,396 SF
---
---
1/2 ALLEY
---
---
---
TOTAL
24,396 SF
---
---
TOTAL ROOF AREA
2,078 SF
---
OTHER
---
---
SUBTOTAL:
2,078 SF
---
2,078 SF
*MAXIMUM ALLOWED LOT COVERAGE
(50% MAXIMUM PER FWRC 19.200.010)
12,198 SF
NOTE:
LOT COVERAGE DIAGRAM
1 /16" = 1'-0"
(E) DECK
o I I
I
I
(E) UPPER I I — (E) MAIN
FLOOR PLAN F I FLOOR
F_
(E) GARAGE
a
0
s
s
0 0 0 0
0
I
NOTE: ---
I
BUILDING AREA DIAGRAM
3 �------I
NOTE: ---
UNCONDITIONED AREA (OUTSIDE FACE) (E) BASEMENT
CONDITIONED AREA (OUTSIDE FACE)
NEW
EXISTING
TOTAL
(N) MAIN FLOOR
---
1,194 SF
---
(N) UPPER FLOOR
---
1,704 SF
---
SUBTOTAL
---
2,898 SF
2,898 SF
NEW
EXISTING
TOTAL
(E) BASEMENT
---
1,194 SF
---
(E) GARAGE
---
440 SF
---
(E) DECK
---
520 SF
---
SUBTOTAL
---
2,154 SF
2,154 SF
APPROXIMATE /
LOCATION OF CLIFF
/
/
/
\
\
\
\
(E) UPPER \FL
EXISTING GRADE _ +162
SITE PLAN NOTES:
1. PROPERTY LINES ARE BASED ON KING COUNTY QUARTER -SECTION MAPS
2. LOCATION OF EXISTING BUILDING IS APPROXIMATE
3. ALL ITEMS ARE EXISTING (E) & TO REMAIN, UNLESS NOTED OTHERWISE, (UNO)
4. (N) INDICATES 'NEW', (E) INDICATES 'EXISTING'.
5. VERIFY LOCATION OF ALL UTILITIES BEFORE DIGGING.
6. SITE SLOPES NW, CONTOURS ACQUIRED FROM KING COUNTY GIS
7. ALL DIMENSIONS AT BUILDINGS ARE TO OUTSIDE FACE OF CONCRETE OR STU[
SITE PLAN
00 1
O
Z
W
i2
VTRY
VELOCIPEDE
ME
3104 Western Avenue #102
Seattle WA 98121
7459
REGISTERED
ARCHITECT
6EOR6E OSiROW
STATE OF WASHINGTON
(D
RESUBMITTED
1/31/2022
CITY OF FEDERAL WAY
COMMUNITY DEVELOP
NT
c�
3
27 JAN 2022
DATE: 9 AUG 2021
PHASE: POST PERMIT
0
PROJECT: 2009
7
DRAWN: JWN
SCALE: 1/8" = 1'-0"
SITE
PLAN
AO-3