Loading...
22-105600-Permit Drawings-12.09.22PROJECT ADDRESS: 35812 15TH AVE SW FEDERAL WAY, WA PROJECT DESCRIPTION: EIGHT (8) PIN PILES ARE TO BE VOLUNTARILY INSTALLED TO PREVENT FURTHER SUBSIDENCE OF THE EXISTING BLDG. TIE -BACKS ARE NOT REQUIRED. LAND USE NOTE: PIER INSTALLATIONS ARE SUBGRADE & DO NOT AFFECT THE EXTERIOR APPEARANCE OF THE STRUCTURE. DESIGN CRITERIA: CODES 2018 WASHINGTON STATE RESIDENTIAL CODE 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) ASCE 7-16 DESIGN LOADS: ROOF DEAD LOAD: 15 PSF ROOF SNOW LOAD: 25 PSF FLOOR DEAD LOAD: 15 PSF FLOOR LIVE LOAD: 40 PSF WIND SPEED: 97 MPH EXP. CATEGORY: C SOILS: ALLOWABLE SOIL BEARING: 1500 PSF ALLOWABLE SOIL PASSIVE: 100 PSF/FT GENERAL ALL DETAIL CUTS SHALL BE CONSIDERED TYPICAL AT LIKE CONDITIONS. WHERE ANY DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENT SHALL GOVERN. ESTABLISH AND VERIFY ALL GEOMETRY FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING CONCERNS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STRUCTURAL STABILITY OF ALL NEW AND EXISTING STRUCTURES DURING CONSTRUCTION. THIS INCLUDES EXCAVATIONS, COLUMNS, EQUIPMENT LOADS, MATERIAL LOADS, AND OTHERS. OBSERVATIONS BY THE ENGINEER —OF —RECORD DO NOT INCLUDE INSPECTIONS OF TEMPORARY LOADING AND STABILITY DURING CONSTRUCTION. HELICAL AND DRIVEN PIERS: ALL PIERS, HELICAL BLADES, FOUNDATION BRACKETS, HARDWARE, ETC., SHALL BE MANUFACTURED BY SUPPORTWORKS, INC., AND DOCUMENTED IN UES EVALUATION REPORT 289. DRIVEN & HELICAL PIERS ARE TO BE INSTALLED BY SUPPORTWORKS—CERTIFIED INSTALLERS. LOCATIONS OF PILES: PILES CAN BE ADJUSTED A DISTANCE OF 2'-0°AS LONG AS THE SPAN BETWEEN THE ADJUSTED PILE AND ADJACENT PILE DOES NOT EXCEED 8'—O'. WHEN THE DISTANCE EXCEEDS 8'-0"CONSULT WITH THE ENGINEER OF RECORD FOR FURTHER DIRECTION. PILES CAN BE PLACED ON THE INTERIOR OR EXTERIOR AS NEEDED TO ACCOMMODATE EXISTING ELEMENTS SUCH AS UTILITIES, EXISTING STRUCTURES, OR OTHER ELEMENTS THAT CANNOT BE MOVED. CONCRETE ANCHORS: CONCRETE ANCHORS (IF REQ-D) SHALL BE SIMPSON OR EQUAL (SPECIAL INSPECTION REQUIRED). SPECIAL INSPECTIONS: THE PIN PILES SHALL BE DRIVEN TO REFUSAL BY A RHINO 140 (140 LB. HAMMER) POST DRIVER. REFUSAL IS DEFINED AS AN ADVANCEMENT RATE LESS THAN OR EQUAL TO 1 INCH WITHIN A 60 SECOND TIME PERIOD. 130't — — — — — PROPERTY � LINE — 40't 35812 15TH AVE SW FEDERAL WAY, WA AREA OF REPAIR SITE PLAN ®® SCALE: NORTH N N O U1 d� O 1 O STARK O FOUNDATIONS 3366 AY DRIVE STAMP � rn � rn ¢ ¢ ono rn � CD ¢ LL U w U5 O r U r ¢ o_ ~ PROJECT 3¢ z w w w Q o c ¢ z N W J rp O co M w RECEIVED PROJ NO.: 22.753.TF5 O issueo. 11.29.22 ❑RAWNBY. BBS CHECKEDBY. DS SHEET TITLE SITE PLAN & NOTES SHEET NUMBER S1.0 0 Dec 12 2022 CITY OF FEDERAL war BACKFILL (E) GRADE I' 4 FOOTING BEYOND o o STANDARD BRACKET CHIP OUT POCKET IN (E) FOOTING (SUPPORTWORKS P/N FS238B-G) FLUSH WITH FDN WALL POCKET 2 7/8.0 (30' OR 48') GUIDE SLEEVE WIDTH TO MATCH BRACKET WIDTH (SUPPORTWORKS P/N FS238ES30-G OR FS238ES48-G) 2 3/8.0 PIER SHAFT (SUPPORTWORKS P/N PP237-G ALT. 2' SCHBO PIPE) 2 3/8.0 STARTER (P/N PP237-G) W/ 2 7/8.0 FRICTION REDUCTION COLLAR n 2 34 � PIN PILE DETAIL L SCALE: 3/I 1'-0' m0 m0 m0 2'} (5) PIN PILES ® 6't O.C. O O O O 0 (E) CRAWL SPACE 62't FRONT OF HOME LEGEND O INDICATES PIN PILES & 10K UNFACTORED DESIGN LOAD (KIPS). SEE DETAIL 2 S2.0 FOUNDATION REPAIR PLAN PLAN NOTES: 1. DO NOT INSTALL PIERS UNDER WINDOWS OR OPENINGS, UNLESS NOTED OTHERWISE 2. PIERS CAN BE ADJUSTED A DISTANCE OF 1'-0"i AS LONG AS THE SPAN BETWEEN THE ADJUSTED PIER AND ADJACENT PIER DOES NOT EXCEED THE MAXIMUM RECOMMENDED SPACING. WHEN THE DISTANCE EXCEEDS THE MAXIMUM RECOMMENDED SPACING, CONSULT WITH THE ENGINEER OF RECORD FOR FURTHER DIRECTION. 3. PIN PILES SHALL BE INSTALLED TO A MINIMUM 2.OX THE DESIGN LOAD, AS NOTED ON THE FOUNDATION REPAIR PLAN TO ACHIEVE AN ULTIMATE AXIAL LOAD OF 16,000 LEIS MINIMUM. PIER EMBEDMENT SHALL BE 8'-O' MIN. RECEIVED Dec 12 2022 cm OF FEDERAL war N N STARK 1 FOUNDATIONS 3366SKY—DRIVE CD30 AUBURN, AL STAMP O O 1 � rn rn ¢ ¢ ono rn CD ¢ LL U w U5:5w o r U r � o_ PROJECT o��U¢ Z w w w Z w = ¢ o c T ¢ J IL o co , PROJ NO.: 22.753.TF5 O issueo. 11.29.22 ❑RAWNBY. BBS CHECKED BY DS SHEET TITLE REPAIR PLAN & DETAILS S HEET NUMBER 0S2.0