Loading...
21-103931-Planset-10-21-2021-V2DESIGNER EIZ Permitting, Inc. REVISIONS NO. ISSUE DATE 8/5/21 1: E E F MANAGMENT PRACTICES FOR 3. The General Contractor or Sub Contractors (hereby to be refered to as the General OWNER LANDLORD Thomas Migwi Kamau C®NTRUCTI®N ACTIVITIES Contractor) shall furnish all labor and materials 920s296thPI, Federal Way, WA 98003 as required to complete demolition and removal of all items as indicated in the APPLICABLE CODES 8c STANDARDS: drawings or as otherwise directed by the 2018 International Building Codes (IBC) With City Federal Way CONSULTANTS Minimum Water Quality Protection Requirements for All Development Designers. _ _ amendment DESIGNER 4. Remove all fixtures, appliances, equipment �= r EZPERMITTING Construction Projects/Certification Statement}��,- 2018 International Residential Code (IRC) Esteban Re Ia and hardware in all areas within the limits 2018 International Mechanical Codes (IMC) 1530SDash Point Rd, Federal o r 1020 Way WA 98003 THE FOLLOWING IS INTENDED MINIMUM NOTES OR AS ATTACHMENT FOR indicated as extent Of work. ' 61012 `�� 2018 International Eire Codes IEC (562)390-50-46 CONSTRUCTION AND GRADING PLANSThe era contractor shall cap and flush � •��� � � ��• � f ( ) AND REPRESENT THE MINIMUM STANDARDS OF GOOD HOUSEKEEPING g P f� 1W 2018 Uniform Plumbing Codes (UPC) j. en WHICH MUST BE IMPLEMENTED ON ALL off behind floor and wall surfaces to remain all asn on State Energy Codes CONTRUCTION SITES REGARDLESS OF SIZE.2020 WhitSttE g gy CdWSEC ( ) projecting plumbing, floor and wall 2020 National Electrical Code (NFPA 70) c f 0 ENRODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON electrical telephone outlets, and all other ` ''`'': 2018 National Design specifications With Wood SITE AND MUST NOT BE TRANSPORTED FROM THE SITE VIA SHEETFLOW, SWALES, AREA DRAINS, projecting items which are being abandoned. �" construction (NDS) ID NATURAL DRAINAGE CURSES ° OR WIND. 6. Protect all existing work from damage by LS p Y rsCkt3 �3 �22 f 0 STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED impact, soiling, water. MATERIALS MUST BE PROTECTED FROM 7. At juncture of work to remain and work to S BEING TRANSPORTED FROM THE SITE BY FORCES OF WIND OR WATER. 0 FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE be demolished, make neat, straight, plumb, �,• °� � 5AP C CART B U LD C C CODES STORED IN ACCORDANCE WITH THEIR 2. 604 LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE even Cuts. i =' WATERS. ALL APPROVED STORAGE 8. The General Contractor shall prevent CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS DIATELY damage to buildinginterior stairs and exterior MUSTAND ED DISPOSED OF IN ACLEANED UP EPROPER MANNER. SPILLS MAY NOT BE g V C TC B A E WASHED INTO THE DRAINAGE SYSTEM. fire escapes, elevators and shafts, facade 0 NON —STORM WATER RUNOFF FROM EQUIPMENT AND VEHICLE WASHING elements, exterior doors, windows, structural AND ANY OTHER ACTIVITY SHALL BE elements steel fireproofing building main PROJECT DESCRIPTION: CONTAINED AT THE PROJECT SITE. PROJECT NAME 0 EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO HE PUBLIC utilities, electric service, domestic water, etc, ASSESSORS'S ID: 515160-0530 CONVERT SINGLE FAMILY RESIDENCE TO CONVERT WAY OR ANY OTHER DRAINAGE as required. PROPERTY TYPE: SINGLE FAMILY RESIDENTIAL ADULT FAMILY HOME SINGLE FAMILY SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES RESIDENCE TO ON SITE UNTIL THEY CAN BE 9. The General Contractor shall drain all ZONING: RS9.6 DISPOSED OF AS SOLID WASTE. and mechanical water supply I lines ADULT FAMILY 0 TRASH AND CONSTRUCTION RELATED SOLIDS WASTES MUST BE plumbing, p p y BEDROOMS/BATHROOMS: 7/1 HOME DEPOSITED INTO A COVERED RECEPTACLE TO and Cap them at their source before SCOPE OF WORK: PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND. proceeding to demolish them. 3/4 BATHS/ 1/2 BATHS: 2/0 0 SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE P g -INTERIOR REMODEL PROJECT ADDRESS SITE BY VEHICLE TRAFFIC. 10. The General Contractor shall use Only -SIX NEW 1/2 BATHROOMS 920 s 296th PI, THE CONSTRUCTION ENTRANCE ROADWAY MUST BE STABILIZEDSO AS licensed and certified sub —contractors for the UNITS: 1 Federal Way, WA TO INHIBIT SEDIMENTS FROM BEING 98003 DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE removal Of refrigerant in existing mechanical LEGAL DESCRIPTION: MARINE HILLS# 1 SWEPT UP IMMEDIATELY AND MAY NOT WASHED DOWN BY RAIN OR OTHER MEANS. lines. Refrigerant to be removed using Only PLAT BLOCK: 11 PLAT LOT: 3 0 ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION EPA, State DEP and locally approved collection MUST BE STABILIZED SO AS TO INHIIBIT P P ��n\\//p�� //^�\ � LOT AREA Per Pierce Count 12,000.00 SQ.FT. EROSION BY WIND AND WATER. methods and equipment. 01 EO T C C COOIVI / T O V ( y): TITLE 11. Demolished materials should be removed COVER PAGE NOTE: CONSTRUCTION TYPE V—B from site in containers or bags and (E) DWELLING 3,600.00 SQ.FT RESUBMITTED passageways and exterior spaces should be A-1.0 COVER PAGE 10/21/2021 DEMOLITION NOTES kept clean continuously. A-1.1 SITE PLAN TOTAL 3,600.00 SQ.FT CITY OF FEDERAL WAY 1. Existing conditions, materials and dimensions 12. Any damage Incurred outside of the scope A-2.0 EXISTING FLOOR PLANS COMMUNITY DEVELOPMENT . indicated are for general information only. of work must be repaired. A-2.1 EXISTING ELEVATIONS 13. The general contractor shall furnish all A-2.2 EXISTING ELEVATIONS PROJECT Remove existing construction completely to labor and materials as required to complete A-2.3 PROPOSED FLOOR PLANS LOT COVERAGE extent indicated or required, whether or not demolition and removal of all items as A-2.4 PROPOSED ELEVATIONS SCALE indicated material configurations and A-2.5 PROPOSED ELEVATIONS 3 600.00 / 12 000.00 SQ.FT. = 0.30 FAR DRAWN BY ' indicated in the drawings or as otherwise DATE dimensions are correct. Verify existing directed by the Designers. S-1.0 STRUCTURAL GENERAL NOTES FAR: 30% Sep 17,2021 conditions. de, will not be recognized. S-1.1 FRAMING PLAN 2. Notify Designer Of discrepancies between S-1.2 STRUCTURAL DETAILS drawings and existing conditions prior to SHEET NUMBER proceeding with work. GENERAL DOTES DEC PROJECT DATA A-1.0 DESIGNER EIZ Permitting, Inc. PROPERTY LINE 109' (E) LANDSCAPE 29'-0" 70, (E) DRIVEWAY 0 0 N OWNER LANDLORD Thomas Migwi Kamau 920 s 296th PI, Federal Way, WA 98003 -On 00, CONSULTANTS DESIGNER EZ PERMITTING Esteban Regla 1530 S Dash Point Rd, Federal Way WA 98003 N RAM CD (562)390-50-46 LO (E) SI GLE M L FAMILY RESIDENCE 4,-0„ C� LLJ 3,600 q. Ft. LLJ Z Z J I J E DECK o >- (0 (E) LANDSCAPE (E) ( ) LANDING Lu (E) LANDSCAPE Lu _ N o CD PROJECT NAME N CONVERT SINGLE FAMILY RESIDENCE TO ADULT FAMILY HOME PROJECT ADDRESS 920 s 296th PI, Federal Way, WA 10'-0" 40'-0" 31'-0" 98003 CD TITLE SITE PLAN RESUBMITTED PROPERTY LINE 109' 10/21/2021 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT PROJECT SCALE DRAWN BY DATE Sep 17, 2021 SHEET NUMBER SITE PLAN SC: 3/16" = 1' A_ 1 . 1 REVISIONS NO. ISSUE DATE 8/5/21