21-103931-Planset-10-21-2021-V2DESIGNER
EIZ
Permitting, Inc.
REVISIONS
NO. ISSUE DATE
8/5/21
1: E E F
MANAGMENT PRACTICES FOR 3. The General Contractor or Sub Contractors
(hereby to be refered to as the General OWNER LANDLORD
Thomas Migwi Kamau
C®NTRUCTI®N ACTIVITIES Contractor) shall furnish all labor and materials 920s296thPI,
Federal Way, WA 98003
as required to complete demolition and
removal of all items as indicated in the APPLICABLE CODES 8c STANDARDS:
drawings or as otherwise directed by the 2018 International Building Codes (IBC) With City
Federal Way
CONSULTANTS
Minimum Water Quality Protection Requirements for All Development Designers. _
_ amendment DESIGNER
4. Remove all fixtures, appliances, equipment �= r EZPERMITTING
Construction Projects/Certification Statement}��,- 2018 International Residential Code (IRC) Esteban Re Ia
and hardware in all areas within the limits
2018 International Mechanical Codes (IMC) 1530SDash Point Rd, Federal
o r 1020 Way WA 98003
THE FOLLOWING IS INTENDED MINIMUM NOTES OR AS ATTACHMENT FOR indicated as extent Of work. ' 61012 `�� 2018 International Eire Codes IEC (562)390-50-46
CONSTRUCTION AND GRADING PLANSThe era contractor shall cap and flush � •��� � � ��• � f ( )
AND REPRESENT THE MINIMUM STANDARDS OF GOOD HOUSEKEEPING g P f� 1W 2018 Uniform Plumbing Codes (UPC)
j. en
WHICH MUST BE IMPLEMENTED ON ALL off behind floor and wall surfaces to remain all asn on State Energy Codes CONTRUCTION SITES REGARDLESS OF SIZE.2020 WhitSttE
g gy CdWSEC ( )
projecting plumbing, floor and wall 2020 National Electrical Code (NFPA 70)
c f
0 ENRODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON electrical telephone outlets, and all other ` ''`'': 2018 National Design specifications With Wood
SITE AND MUST NOT BE
TRANSPORTED FROM THE SITE VIA SHEETFLOW, SWALES, AREA DRAINS, projecting items which are being abandoned. �" construction (NDS)
ID
NATURAL DRAINAGE CURSES °
OR WIND. 6. Protect all existing work from damage by
LS
p Y rsCkt3 �3 �22 f
0 STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED impact, soiling, water.
MATERIALS MUST BE PROTECTED FROM 7. At juncture of work to remain and work to S
BEING TRANSPORTED FROM THE SITE BY FORCES OF WIND OR WATER.
0 FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE be demolished, make neat, straight, plumb, �,• °� � 5AP C CART B U LD C C CODES
STORED IN ACCORDANCE WITH THEIR 2. 604
LISTING AND ARE NOT TO CONTAMINATE THE SOIL AND SURFACE even Cuts. i ='
WATERS. ALL APPROVED STORAGE 8. The General Contractor shall prevent
CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS DIATELY damage to buildinginterior stairs and exterior
MUSTAND ED DISPOSED OF IN ACLEANED UP EPROPER MANNER. SPILLS MAY NOT BE g V C TC B A E
WASHED INTO THE DRAINAGE SYSTEM. fire escapes, elevators and shafts, facade
0 NON —STORM WATER RUNOFF FROM EQUIPMENT AND VEHICLE WASHING elements, exterior doors, windows, structural
AND ANY OTHER ACTIVITY SHALL BE elements steel fireproofing building main
PROJECT DESCRIPTION:
CONTAINED AT THE PROJECT SITE. PROJECT NAME
0 EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO HE PUBLIC utilities, electric service, domestic water, etc, ASSESSORS'S ID: 515160-0530 CONVERT SINGLE FAMILY RESIDENCE TO CONVERT
WAY OR ANY OTHER DRAINAGE as required. PROPERTY TYPE: SINGLE FAMILY RESIDENTIAL ADULT FAMILY HOME SINGLE FAMILY
SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES RESIDENCE TO
ON SITE UNTIL THEY CAN BE 9. The General Contractor shall drain all ZONING: RS9.6
DISPOSED OF AS SOLID WASTE. and mechanical water supply I lines ADULT FAMILY
0 TRASH AND CONSTRUCTION RELATED SOLIDS WASTES MUST BE plumbing, p p y BEDROOMS/BATHROOMS: 7/1 HOME
DEPOSITED INTO A COVERED RECEPTACLE TO and Cap them at their source before SCOPE OF WORK:
PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND. proceeding to demolish them. 3/4 BATHS/ 1/2 BATHS: 2/0
0 SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE P g -INTERIOR REMODEL PROJECT ADDRESS
SITE BY VEHICLE TRAFFIC. 10. The General Contractor shall use Only -SIX NEW 1/2 BATHROOMS 920 s 296th PI,
THE CONSTRUCTION ENTRANCE ROADWAY MUST BE STABILIZEDSO AS licensed and certified sub —contractors for the UNITS: 1 Federal Way, WA
TO INHIBIT SEDIMENTS FROM BEING 98003
DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE removal Of refrigerant in existing mechanical LEGAL DESCRIPTION: MARINE HILLS# 1
SWEPT UP IMMEDIATELY AND MAY
NOT WASHED DOWN BY RAIN OR OTHER MEANS. lines. Refrigerant to be removed using Only PLAT BLOCK: 11 PLAT LOT: 3
0 ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION EPA, State DEP and locally approved collection
MUST BE STABILIZED SO AS TO INHIIBIT P P ��n\\//p�� //^�\ � LOT AREA Per Pierce Count 12,000.00 SQ.FT.
EROSION BY WIND AND WATER. methods and equipment. 01 EO T C C COOIVI / T O V ( y): TITLE
11. Demolished materials should be removed COVER PAGE
NOTE: CONSTRUCTION TYPE V—B from site in containers or bags and (E) DWELLING 3,600.00 SQ.FT RESUBMITTED
passageways and exterior spaces should be A-1.0 COVER PAGE 10/21/2021
DEMOLITION NOTES kept clean continuously. A-1.1 SITE PLAN TOTAL 3,600.00 SQ.FT CITY OF FEDERAL WAY
1. Existing conditions, materials and dimensions
12. Any damage Incurred outside of the scope A-2.0 EXISTING FLOOR PLANS COMMUNITY DEVELOPMENT
.
indicated are for general information only. of work must be repaired. A-2.1 EXISTING ELEVATIONS
13. The general contractor shall furnish all A-2.2 EXISTING ELEVATIONS PROJECT
Remove existing construction completely to labor and materials as required to complete A-2.3 PROPOSED FLOOR PLANS LOT COVERAGE
extent indicated or required, whether or not demolition and removal of all items as A-2.4 PROPOSED ELEVATIONS SCALE
indicated material configurations and A-2.5 PROPOSED ELEVATIONS 3 600.00 / 12 000.00 SQ.FT. = 0.30 FAR DRAWN BY
' indicated in the drawings or as otherwise DATE
dimensions are correct. Verify existing directed by the Designers. S-1.0 STRUCTURAL GENERAL NOTES FAR: 30% Sep 17,2021
conditions. de, will not be recognized. S-1.1 FRAMING PLAN
2. Notify Designer Of discrepancies between S-1.2 STRUCTURAL DETAILS
drawings and existing conditions prior to
SHEET NUMBER
proceeding with work. GENERAL DOTES DEC PROJECT DATA A-1.0
DESIGNER
EIZ
Permitting, Inc.
PROPERTY LINE 109'
(E) LANDSCAPE
29'-0" 70,
(E) DRIVEWAY
0
0
N
OWNER LANDLORD
Thomas Migwi Kamau
920 s 296th PI,
Federal Way, WA 98003
-On
00,
CONSULTANTS
DESIGNER
EZ PERMITTING
Esteban Regla
1530 S Dash Point Rd, Federal
Way WA 98003
N RAM CD (562)390-50-46
LO (E) SI GLE M L
FAMILY RESIDENCE 4,-0„ C�
LLJ 3,600 q. Ft. LLJ
Z Z
J I J
E DECK o >- (0
(E) LANDSCAPE (E) ( ) LANDING
Lu (E) LANDSCAPE Lu
_ N
o
CD
PROJECT NAME
N CONVERT
SINGLE FAMILY
RESIDENCE TO
ADULT FAMILY
HOME
PROJECT ADDRESS
920 s 296th PI,
Federal Way, WA
10'-0" 40'-0" 31'-0" 98003
CD
TITLE
SITE PLAN
RESUBMITTED
PROPERTY LINE 109' 10/21/2021
CITY OF FEDERAL WAY
COMMUNITY DEVELOPMENT
PROJECT
SCALE
DRAWN BY
DATE
Sep 17, 2021
SHEET NUMBER
SITE PLAN
SC: 3/16" = 1' A_ 1 . 1
REVISIONS
NO.
ISSUE
DATE
8/5/21