23-100779City of Federal Way jl Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: BOYS AND GIRLS CLUB Project Address: 30815 8TH AVE S Building - Commercial Permit #:23-100779-00-CO Inspection Request Line: (253) 835-3050 Parcel Number: 082104 9058 Project Description: BLUEBEAM - Construction of a pump room into an existing Boys and Girls Club facility. The project includes addition of a 1hr rated new door, (1) one hour rated wall, new finishes, new maintenance disconnect. No plumbing or mechanical. Owner Applicant Contractor Lender BOYS & GIRLS CLUBS REI SCHULTZCUSHING TERRELL FERGUSON CONSTRUCTION INC OWNER IS LENDER 603 STEWART ST UNIT 300 1201 WESTERN AVE SUITE 700 (GENERAL) SEATTLE, WA 98101-1289 SEATTLE WA 98101 3810 SE EASTGATE WAY SUITE 11 BELLEVUE WA 980054432 Census Category: 437 - Commercial alt / add / conversion Includes: #1 #2 61 #4 Occupancy Class: Construction Type. Occupancy Load: Floor Area (sq. ft.) 0.00 Additional Permit Information Mechanical to be Included? ..................................... No Plumbing Work Valuation?..................................... 0 Mechanical Work Valuation? .................................. 0 Number of Stories................................................... I Is this an Online or O.T.C. application? .................. No Permit for Building Shell Only?.............................. No Plumbing to be Included? ........................................ No Comprehensive Plan Designation......................:.... SF - High -Density Residential Zoning Designation ................................................. RS 7.2 Total Valuation: 350,000.00 No Fbmifvs mated WM This Permft it CONDITIONS: FIRE APPROVAL CONDITIONS: k's 4L, , 1) Demolition and construction shall conform to the requirements of IFC Chapter 33 and NFPA 241 Standard. 2) Where provided, fire pump rooms and automatic sprinkler system riser rooms shall be designed with adequate space for all equipment necessary for the installation, as defined by the manufacturer, with sufficient working space around the stationary equipment. 3) Separate construction permits are required for new, or existing fire protection or detection systems where modifications or revisions have been made. 4) Call 253-946-7318 to schedule your inspection. Please schedule your inspection at least 2 business days in advance. The fire marshals office will call you back and set up an agreed upon time. Preferred inspection days are Tuesdav throueh Thursdav with limited inspection availability on M.onday's and Friday'S. PERMIT EXPIRES Saturday, 14 October, 2023 Permit Issued on Monday, April 17, 2023 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washinjand ity of Federal Way. Owner or agent: Date: CITY OF a� Federal Way PERMIT #: Project: THIS CARD IS TO REMAIN ON -SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 23 100779 00 Address: 30815 8TH AVE S BOYS & GIRLS CLUBS FEDERAL WAY WA 98003-4701 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. ❑- Footings/Setback (4110) Re -steel (4215) Slab/Concrete Floor (4255) Approved to place concrete Approved to place concrete or grout Approved to place concrete By Date By Date By Date Underfloor Framing (4285) Floor Sheathing (4105) Fire/Draft Stops (4095) Approved to sheath floor Approved to install flooring Approved By Date By Date By Date Prior to :scheduling a Framing inspection; El Framing (4120) ® Insulation (4150) Electrical,mbing & Mechanical Rough -in Approved to insulate Approved to install wallboard and Fire/DStop inspections must be signed-Roff approved. IBC 1091.3.4 By L V Date (Q!(3 /%� By Date it Gypsum Wallboard Nailing (4130) l� Approved to install mud & tape By Date 1(j '��jy By 12 Final - Planning Approved rBy By Date G r V l W 5 0' Tkire— Suspended 1 Final - S K F& R (4060) Approved By Date C0 v1- R_ Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date CIT1f. OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, 980viz*�41111103-6325 y Phone 253-835-2607 Faxx 253-835835-2609 CORRECTION NOTICE ADDRESS: ;�V N0 �1 4A J PERMIT#:25-1 QO % P-06) IF YOU HAVE QUESTIONS CALL (253) 835- - S�ow WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 5-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. ATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of _� ....._ raw ovUrvu UUN I HUL DESIGN MANUAL WALLS AND INTERIOR PARTITIONS, NONCOMBUSTIBLE GA FILE NO. PROPRIETARY W P 0900 GYPSUM PANELS, STEEL STUDS, INSULATION Fire Design: One layer of 5/8" proprietary type X factory -laminated panels applied parallel to both sides of a double row of 3-5/8", 15 mil steel studs at max 24" o.c. and 1" airspace with 1-1/4" No. 6, Type S screws spaced at 8 in. o.c. along the perimeter and 12 in. o.c. in the field. 3-1/2" glass fiber insulation friction fit into both sides of stud cavity. Vertical joints centered over studs and staggered one stud cavity on opposite sides. Horizontal joints of vertically applied panels to be staggered 4 ft on opposite sides of the wall. (NLB) Sound Design: Sound tested on studs spaced 16" o.c. PROPRIETARY GYPSUM PANEL PABCO® Gypsum — 5/8" QuietRock® ES Type X GA FILE NO. + PROPRIETARY WP 0950 I GYPSUM PANELS, STEEL STUDS Fire Design: One layer 5/8" proprietary type X gypsum panels applied parallel to both sides of 3-5/8", 18 mil steel studs spaced 24" o.c. with I" Type S screws 8" o.c. at vertical joints and wall perimeter and 12" o.c. in the field. Joints staggered on opposite sides. (NLB) Sound Design: Sound tested with resilient channels fastened perpendicular at 24"o.c. to ONE SIDE of the studs. An additional layer of 5/8" proprietary type X gypsum panels applied parallel to both sides of steel studs with 1-518" Type S screws W o.c. at vertical joints and wall perimeter and 12" o.c. in the field. 3-1/2" glass fiber insulation friction fit in stud cavity. PROPRIETARY GYPSUM PANEL PABCO® Gypsum — 5/8" FLAME CURB" Type X ©2021 by the Gypsum Association www.gypsum.org 1 HOUR 65 to 69 STC FIRE I SOUND Thickness: 9-1/2" (Fire and Sound) Approx.Weight: 6.7 psf (Fire and Sound) Fire Test: UL R7094, 09CA55843 TRS, 6-10-10, UL Design V464 Configuration C Sound Test: NOAL 17-0924, 09-20-2017 1 HOUR 60 to 64 STC FIRE I SOUND Thickness: 4-7/8" (Fire) 6-5/8" (Sound) Approx Weight: 4.9 psf (Fire) 9.3 psf (Sound) Fire Test: UL R7094, 07CA62488, 4-01-2008, UL Design U465 Sound Test: NOAL 17-0531, 05-18-2017 358 GA-600-2021 FIRE RESISTANCE AND SOUND CONTROL DESIGN MANUAL C HORIZONTAL MEMBRANE SYSTEMS GA FILE NO. I PROPRIETARY HM 7104 1 STEEL JOISTS, GYPSUM PANELS Fire Design: Perimeter channels, 6", 33 mil with 1-1/4" legs attached to side walls with fasteners spaced 24" o.c. Steel joists, 6", 33 mil attached to top leg of perimeter channels with 112" pan head screws, and spaced 16" o.c. Flat strap, 2", 33 mil or perimeter channels secured to top of joists at centerline line of the span with one 112" pan head screw at each joist. Base layer 518" proprietary type X gypsum panel applied at right angles to steel joists with 1-1 /4"1-ype S screws spaced i 6" o.c. Second layer 5/6" proprietary type X gypsum panel applied at right angles to framing with 1-5/8"Type S screws 16" o.c. with end joints staggered 32" from base layer and tapered joints staggered 12" from base layer. Face layer of 5/8 proprietary type X gypsum panel applied at right angles to framing with 2-1/4"Type S screws 12" o.c. with end joints staggered 24" from second layer and tapered joints staggered 12" from second layer, (NLB) PROPRIETARY GYPSUM PANEL United States Gypsum Company — 5/8" Sheetrock" Brand EcoSmart Panels Firecode® X 1 HOUR FIRE Thickness: 7-7/8" (Fire) Approx. Weight: 6.2 psf (Fire) Fire Test: UL R1319, 4788273046, 3-29-18, UL Design 1506, System A The descriptions in this manual are summaries. For complete assembly information, review the listed design. ©2021 by the Gypsum Association www.gypsum.org