Loading...
07-104460CITY OF Federal August 23, 2007 CITY HALL Way 33325 8th Avenue South Mailing Address: PO Box 9718 Federal Way, WA 98063-9718 (253) 835-7000 www cityoffederalway. com Infrastructure Consulting Corporation Attn: Shailesh Tatu, P.E. 1082 Kirkland Ave NE, Suite B Renton, WA 98056 RE; Permit No, 07-104460-00-SM; BRADSHAW SHORT PLAT 2964418th Ave S; Right -of -Way Modification Response Dear Shailesh: This letter responds to your requests to modify various code requirements pertaining to your proposed three lot short plat at the address listed above. 1. You have requested to waive the required block perimeter standards for this project. All new development is required to accommodate the block perimeter standards for both vehicular and pedestrian circulation, if possible. After evaluating the existing conditions along the roadway, review of Federal Way City Code (FWCC) provisions (Sections 22-1477, 22-1496), and direction provided by the City Council, the Public Works Department hereby waives the requirements for both vehicular and pedestrian block perimeters based on the following: FWCC Section 22-1477 — Modifications of Improvements Along Property Frontage: This code section allows the Public Works Department to grant a request to modify, defer, or waive the required street improvements only after consideration of four specific reasons. The reason most applicable here is contained in FWCC 22-1477(2) "Unusual topographic or physical conditions preclude the construction of improvements as required." 2. You have requested to modify the required internal street improvements for the above -referenced property. Since the pre -application meeting summary letter was sent to you in September 2006, the City has added new street standard drawings, one of which specifically addresses your situation. Your project no longer needs to meet the requirements of street drawing number 3-2Y (Type "Y" cross section) as originally stated. Instead, your project is now required to conform to street drawing number 3-2DD (Type "DD" cross section). This cross section includes 20-feet of paved driveway within a 25-foot joint use access and utility easement. Beyond the required distance for the turn -around, a single-family driveway may be constructed to access the remaining proposed lot. All common access portions must be contained within a joint access/ingress/egress and utility easement benefiting all proposed lots. L: \CSDC\DOCS\SAVE\23189595066. DOC Infrastructure Consulting Corporation, Attn: Shailesh Tatu, P.E. RE: Permit No. 07-104460-00-SM; BRADSHAW SHORT PLAT August 23, 2007 Page Two 3. You have requested to use a hammerhead style turnaround in lieu of a cul-de-sac style turnaround. This is a fire department requirement; permission to use a hammerhead style turnaround will need to be obtained from the fire department. Contact Chris Ingham, Deputy Fire Marshal at (253) 839-6234. The conditions of this Right -of -Way Modification will be applicable for a period of one year from the date of this letter. If a building permit is not issued within the one-year time limit, this waiver will be void, and a new request for modification request must be submitted. If you have any questions, please contact Sean Wells, Senior Engineering Plans Reviewer, at (253) 835-2731. Sincerely, Ken Miller, P.E. - Deputy Public Works Director KM/SRW:cb Enclosure: Detail3-2DD cc: David Lee, Planner, Community Development and Planning Project File/SRW Day File L: \CSDC\DOCS\SAVE\23189595066. DOC f f- O N] [Infrastructure Consulting Corporation] August 9, 2007 Mr. David Lee Associate Planner City of Federal Way PO Box 9718 Federal Way, WA 98063 RECR v E® Civil/Transportation Engineering AUG Q � �SurEv''eying Construction Management CITY OFFEDERAL WAY U l V BUILDING DEFT, Subject: Bradshaw Short Plat — Request for Waivers 29644 18th Avenue South, File #06-103536-00-PC Dear Mr. Lee, An application for a short plat at the above property is being submitted along with this request for waivers. Above single family residential parcel is to be divided in to three single famiiy' residential parcels. Following waivers are requested: Block Perimeter Waiver FWCC Section 20-151(d) and FWCP Policy TP21, require block perimeters no longer than 1320 feet for non -motorized trips, and 2640 feet for streets. Due the topography in the vicinity of the project site such block perimeters are not feasible. Therefore we request a waiver for these requirements. Waiver of Street Right of Way/Width, Sidewalk, & Cul-de Sac Requirements Public Works Standards drawing 3-1A requires a 24 feet street with curb/gutter, 5' sidewalks, and street lights in a 38 feet right of way. Also, a cul-de-sac is required. Other recent adjacent developments along 18th Avenue South have not been developed to such standards. Therefore, to be consistent with the development along 18t" Avenue South, we request that the proposed development be allowed to construct a 20 feet internal access road without curb/gutter, sidewalks, and street lights. We also request that a hammerhead turnaround be allowed in lieu of a cul-de-sac. If we can be of any assistance in this matter, please contact us. Thank you. Sincerely, CIf* Shailesh Tatu, P.E. Area Manager T (425) 272-1020 F (425) 272-1021 E statu@iconengrs.com ICON a subsidiary of SACORP 1082 Kirkland Avenue NE, Suite B; Renton, WA 98056 Both are certified M/DBE firms Phone (425) 272-1020 [] Fax (425) 272-1021