Loading...
22-104893-Site Plan-10-25-2222-104893 000•I• 0000•�• ram' 00000 SW 321s �.�'0•� • 1 • i' i' .00 0000'� EXISTING RESIDENCE STRUCTURE EXISTING ADJACENT STRUCTURE AREA OF PROPOSED WORK PROPERTY LINE APPROXIMATE DIMENSION r-� I � I � Q� I W W • �L I � I � I � ♦ 00 • �\ (E) CHIMNEY �`' cn W U RESIDENCE 26'-0" 4129 SW 321 ST ST • FEDERAL WAY, WA 98023 Lu I -- ----- zl N --------------- ` JCDr— I elf■ c Lu I oo OOf0- co I ` � , I , I AF DRK I ' I ` ■ I I I I � I I ■ I - — - — - — - — - — - — - — - — - — - — I I I I I I ■ • I � '♦ 000 00010 .0000 me` ,' k '♦� PR .`9.0•,� '♦�♦� pR0 • ♦ r� NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. T PILE SPACING &LOAD REQUIREMENTS TABLE MAX O.C. SPACING, ft MIN VERTICAL CAPACITY, kips PROOF TESTING LOAD, kips PILE #PILE TYPE BTWN PILES END OFFSET ALLOWABLE LOADING 200%MIN VERTICAL CAPACITY (MIN ULTIMATE CAPACITY) LOCATION 1-3 HELICAL 8`-O" PER PLAN 9.0 k/PILE 18.0 k/PILE EXTERIOR 4-7 S` 011 9.0 k/PILE 18.0 k/PILE EXTERIOR 8-9 13.0 k/PILE 26.0 k/PILE EXTERIOR NC)TFS• a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE MANUFACTURER. THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING CAPACITY LOADING, INCLUDING A SAFETY FACTOR NO LESS THAN 2. THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY. MAXIMUM INSTALLATION TORQUE RATING OF 8,300FT*LBS FORA 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL THICKNESS PER ESR-3750. b. FOR HELICAL PILES, PER IDEAL GROUP DWG NO.: 278TFG, THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS. c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING, INC., IN ACCORDANCE WITH ESR-3750. d. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART OF THE ASSEMBLY. e. MAXIMUM ON -CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. FOUNDATION NOTES 1. VERIFY ALL DIMENSIONS ON SITE. 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER R&R LEVEL SURVEY. [cm:1q9giri1aiY•]I�•]►1►11►Eel �]�F_11�y7•]:i_1�1�]11[•]►1_1i1►1Y•7:1►�/_�IIs] ►1 HELICAL PILE .......... 1/SD-1.1 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED OCTOBER 13TH, 2022, FOR ADDITIONAL INFORMATION, SPECIFICATIONS, AND REQUIREMENTS. 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED AUGUST 25TH, 2022. REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8". 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH ± 0'-6" TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION AS INDICATED ON LEVEL SURVEY. 9. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8" THICK MINIMUM WITH 2'-8"HEIGHT (MEASURED FROM BIFTG TO TICONC) MINIMUM. 10. PARCEL DIMENSIONS AND RESIDENCE LOCATING DIMENSIONS (WITH ASTERISK, *) APPROXIMATED PER KING COUNTY iMAP. NOT TO BE USED FOR LEGAL PURPOSES. 11. SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. 12. PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'-0" (UNO PER GEOTECHNICAL REPORT). HELICAL PILE REFUSAL CRITERIA: TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO. ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. INSTALLATION/EXCAVATION NOTE: ALL REQUIRED HOLES FOR PILE INSTALLATION SHALL BE DUG BY HAND, SHALL NOT EXCEED 2'x2'x2', AND MUST BE IN ACCORDANCE WITH THE SEATTLE GRADING CODE. CONTRACTOR TO ENSURE THAT PROJECT STRUCTURE AND ADJACENT PROPERTIES AND STRUCTURES ARE NOT IMPACTED BY THE INSTALLATION OF PILES. IN MEN. IN 0 MEN MmmMEMIMlOM`WEM ME • ■ ■iiAwiA■ iii�ii■■ ■ ■■■ ■■>■■■ ■ ■ !■■■i■■�lr!■■!!!!■ ■■■>r� it■■■ i E�� t�� SITE PE�qlvE° Nov 28 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT W z o w di Z �> w zwZ z Z O O w J REVISIONS 0 DESCRIPTION DATE BY PROJECT NAME 4129 SW 321ST ST FEDERAL WAY WA 98023 PROJECT NtJ, ,dER S221013-3XR DRAWN ui - JT CHECKED BY M RT SHEET DATE 10/13/2022 sc;, z z o Q J N � 11 Ln � W V p (f) w w