Loading...
24-101579City of Federal Way Community Development Dept. 33325 Sth Ave S FINALED Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Building - Single Family Permit #:24-101579-00-SF Inspection Request Line: (253) 835-3050 Project Name: EVOLVING ADULT HOME CARE Project Address: 2315 S 292ND ST Parcel Number: 4222600050 Project Description: Verification of Occupancy for Adult Family Home. ***No construction work allowed under this permit.*** Owner Applicant Contractor Lender BIRENDRA KHADKA EMMANUEL 11510 SE 302ND CT NDAYISENGAEVOLVING ADULT HOME CARE LLC AUBURN WA 98082 2315 S 292ND ST FEDERAL WAY WA 98003 Census Category: 434 - Residential alt/add - no change in number of units Includes: # 1 #2 #3 #4 Occu anc Class: R-3 Construction Type: Type V- B Occupancy Load: Floor Area (sq. ft.) Additional Permit Information Occupancy #1 - Construction Type .............. Type V - B Mechanical to be Included? ... 4... ........ 4.................... No Is this an Online or O.T.C. application? .................. Yes Plumbing to be Included? ........................ ..... .......... . No Occupancy # I - Use...................................Residence (I or 2 Comprehensive Plan Designation ........................... SF - High -Density .....:...... . family) Residential Zoning Designation..,............. .......i_ RS 7.2 No Fixtures Associated With This Permit H PERMIT EXPIRES Tuesday, S October, 2024 Permit Issued on Thursday, April 11, 2024 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date:, 0:�k� Federal Way I CITY OF ' Bdilding Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE 11 ADDRESS: Z3LS s V1-2, s PERMIT#: z4.- 10I.S7�1 L- Co-0-MILuIr'I Q_ ra SN l 1J C-, Or 0"ft-cp ru- -r-t7 33``— 3C�" t r► �4IGT44 r ;,A_ n c-V-5-6 5 /T- D z[J�►u� 4 IZclD IN�q O Q�� LA) P c N 7wS377 A rrr- W R-t 9 P-v-'t> O P T 06T_ Wo bPL- t4TpNJ Tv UN Lucy— t. a Gt�- �. T-7 IF YOU HAVE QUESTIONS CALL W6__ (253) 835- z-67-1 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2018 IRC Section R330 (WAC 51-51) L� 1 APPLICATION NUMBER: SECTIONS 1. 2. 3. AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION WILL BE PROCESSED SECTION 1— PROPERTY INFORMATION SITE ADDRESS: ]7�,1 rY1/ =C 3 / • Fa'r-? iI,� ASSESSOR'STAXIPARCEL#:_______-____ _ ` 7 rJr .� .�• PROPERTY OWNER NAME: 6 j il!ll fj L ' � Atif91 k-h ❑ fft/;V NF LDAYTIME PHONE:, -A. c 4 - � i� - 3 G `l i AFH LICENSEE NAME (IF DIFFERENT): tJ ;)EL df j A GGI'" DAYTIME DAYTIME PHONE: � 7 — �t T SECTION 3 — FLOOR PLAN On a separate sheet of paper (8 1/2x 11) draw a floor plan (including all floors) of your prospective AFH. Include all sleeping rooms (bedrooms) indicating which bedroom is: A, B, C D, E and F. Label all components for exiting i.e., stairs, ramps, platforms, lifts and elevators. SECTION 4 — DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the hest of my knowledge, and that I am requesting or I am authorized by the owner of the above premises to request Inspection For the operation of an Adult Family Home at this location. I agree to hold harmless the jurisdiction conducting such inspections, at my request, as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation of such claim), which may be made by any person, including the undersigned, and filed against the jurlsdiction, but only where such claim arises out of the reliance of the jurisdiction, including its officers and employees, upon the accuracy of the information supplied to the jurisdiction as a part of this application.) ^� 7 NAME/TITLE: J i ` '� L " !.S IA,¢g `-t r DATE: C` y O PROPERTY OWNER OAPPLICANT Q LICENSEE Implementation Date: 2021 February 01 Updated: 2021 February (Effective Feb. 1, 2021 WAC 51-51-0330 Section R330 — Adult family homes. SECTION R330 - ---- - - ADULT FAMILY HOMES _ -----_-- R330.1 General. This section shall apply to all newly constructed adult family homes and all existing single family homes being converted to adult family homes. This section shall not apply to those adult family homes licensed by the state of Washington department of social and health services prior to July 1, 2001, R330.2 Reserved. R330.3 Sleeping room classification. Each sleeping room in an adult family home shall be classified as: 1. Type S - Where the means of egress contains stairs, elevators or platform lifts. 2. Type NS1 - Where one means of egress is at grade level or a ramp constructed in accordance with R330.9 is provided. 3. Type NS2 - Where two means of egress are at grade level or ramps constructed in accordance with R330.9 are provided. R330.4 Types of locking devices and door activation. All bedroom and bathroom doors shall be openable from the outside when locked. Every closet shall be readily openable from the inside. Operable parts of door handles, pulls, latches, locks and other devices installed in adult family homes shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. Pocket doors shall have graspable hardware available when in the closed or open position. The force required to activate operable parts shall be 5.0 pounds (22.2 N) maximum. Required exit doors shall have no additional locking devices. Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing reentry into the adult family home without the use of a key, tool or special knowledge. R330.5 Smoke and carbon monoxide alarm requirements. All adult family homes shall be equipped with smoke and carbon monoxide alarms installed as required in Sections R314 and R315.1. Alarms shall be installed in such a manner so that the detection device warning is audible from all areas of the dwelling upon activation of a single alarm. R330.6 Escape windows and doors. Every sleeping room shall be provided with emergency escape and rescue windows as required by Section R310. No alternatives to the sill height such as steps, raised platforms or other devices placed by the openings will be approved as meeting this requirement. R330.7 Fire apparatus access roads and water supply for fire protection. Adult family homes shall be served by fire apparatus access roads and water supplies meeting the requirements of the local jurisdiction. R330.8 Grab bar general requirements. Where facilities are designated for use by adult family home clients, grab bars for water closets, bathtubs and shower stalls shall be installed according to this section. R330.8.1 Grab bar cross section. Grab bars with a circular cross section shall have an outside diameter of 1 1/4 inches minimum and 2 inches maximum. Grab bars with noncircular cross section shall have a cross section dimension of 2 inches maximum and a perimeter dimension of 4 inches minimum and 4 5/8 inches maximum. R330.8.2 Grab bar installation. Grab bars shall have a spacing of 1 112 inches between the wall and the bar. Projecting objects, control valves and bathtub or shower stall enclosure features above, below and at the ends of the grab bar shall have a clear space of 1 1/2 inches to the grab bar. EXCEPTION: Swing -up grab bars shall not be required to meet the 1 1/2 inch spacing requirement. Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar, fastener, mounting device or supporting structural member. Grab bars shall not be supported directly by any residential grade fiberglass bathing or showering unit. Acrylic bars found in bathing units shall be removed. Fixed position grab bars, when mounted, shall not rotate, spin or move and have a graspable surface finish. R330.8.3 Grab bars at water closets. Water closets shall have grab bars mounted on both sides. Grab bars can be a combination of fixed position and swing -up bars. Grab bars shall meet the requirements of R330.8. Grab bars shall mount between 33 inches and 36 inches above floor grade. Centerline distance between grab bars, regardless of type used, shall be between 25 inches minimum and 30 inches maximum. Implementation Date: 2021 February 01 Updated: 2021 February R330.8.3.1 Fixed position grab bars. Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from the rear wall. R330.." 2 swing -up -grab -bars. Swing -up grab bars shall be a minimum of 28 inches in length from the rear wall. R330.8.4 Grab bars at bathtubs. Horizontal and vertical grab bars shall meet the requirements of R330.8. R330.8A.1 Vertical grab bars. Vertical grab bars shalt be a minimum of 18 inches long and installed at the control end wall and head end wall. Grab bars shall mount within 4 inches of the exterior of the bath tub edge or within 4 inches within the bath tub. The bottom end of the bar shall start between 36 inches and 42 inches above floor grade. EXCEPTION: The required vertical grab bar can be substituted with a floor to ceiling grab bar meeting the requirements of R330.8 at the control end and head end entry points. R330.8.4.2 Horizontal grab bars. Horizontal grab bars shall be provided at the control end, head end, and the back wall within the bathtub area. Grab bars shall be mounted between 33 inches and 36 inches above floor grade. Control end and head end grab bars shad be 24 inches minimurn in length. Back wall grab bar shall be 36 inches minimum in length. R330.8.5 Grab bars at shower stalls. Where shower stalls are provided to meet the requirements for bathing facilities, grab bars shall meet the requirements of R330.8. EXCEPTION: Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab bars at the seat end wall. A vertical floor to ceiling grab bar shall be installed within 4 inches of the exterior of the shower aligned with the nose of the built-in seat. R330.8.5.1 Vertical grab bars. Vertical grab bars shall be 18 inches minimum in length and installed at the control end wall and head end wall. Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower stall. The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. ' R330.8.5.2 Horizontal grab bars. Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 inches and 36 incites above the floor grade. Horizontal ycab bars shall be a maximum of 6 inches from adjacent walls. Horizontal grab bars shall not interfere with shower control valves. R330.9 Ramps. All interior and exterior ramps, when provided, shall be constructed in accordance with Section R311.8 with a maximum slope of 1 vertical to 12 horizontal. The exception to R311.8.1 is not allowed for adult family homes. Handrails shall be installed in accordance with R330.9.1. R330.9.1 Handrails for ramps. Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal and 1 vertical and 20 horizontal in accordance with R311.8.3.1 through R311.8.3.3. R330.10 Stair treads and risers. Stair treads and risers shall be constructed in accordance with R311.7.5. Handrails shall be installed in accordance with R330.10.1. R330.10.1 Handrails for treads and risers. Handrails shall be installed on both sides of treads and risers numbering from one riser to multiple risers. Handrails shall be installed in accordance with R311.7.8.1 through R311.7.8.4 R330.11 Shower stalls. Where provided to meet the requirements for bathing facilities, the minimum size of shower stalls for an adult family home shall be 30 inches deep by 48 inches long. [statutory Authority: RCW 19.27.031 and chapters 19.27 and 34.05 RCW. 13-04-068, § 51-51-0325. Filed 211113, effective 711113. Statutory Authority: Chapter 1927.RCW. 10-18-036. § 51-51-0325, filed 8125/10, effective 13/25110. Statutory Authority: RCW 19.27.190, 19.27.020. and chapters 19.27 and 34_05 RCW. 09-04-023. § 51-51-0325, filed 1127109, effective 711110. Statutory Authority: RCW t9.27.074, 19.27.02�], and chaled tatutory uthority: RCW 19-27-031 and 19-27-0 01-109, §ters1and 51-51-0325, filed 2" 003. effective a 711�04.][Stat1-0325. FutorylA Authority: RCW 19.27 ti3 Sand 19 7.074. WSR 20-03-023, § 5151 0330, filed 4 1/6/20, effective 7/1/20.1 Implementation Date: 2021 February 01 Updated: 2021 February SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN —USING THEIR PROSPECTIVE RESIDENT BEDROOM DESIGNATIONS OF A B C D E AND F AND CLASSIFICATION CODE S, NS1 OR NS2. SECTION 5 — BUILDING INSPECTOR'S INSPECTION CHECKLIST R330.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: Type S — where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area. Type NS1—where 1 means of egress at grade level (has no stairs) or ramp constructed compliant with R330.9 is provided to evacuate residents to public area. Type NS2 — where 2 means of egress at grade level (both have no stairs) or ramps constructed compliant with R330.9 are provided to evacuate residents to public area. NS1 OType NS2 YES SLEEPING ROOM A OType S Tyfflarm NO Closet door/s are readily openable from the inside 19fYesP113No ON/A Smokis installed in the bedroom Bedroom door opens easily and quickl from the o tside when locked t3 13 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) ;3 13 EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44" above floor to clear openin ; no steps under window allowed 0 SLEEPING ROOM B Type S Type NS1 E3 Type NS2 YES NO Closet door/s are read ily.openable from the inside Yes 0 No [3N/A Smoke alarm is installed in the bedroom 0 Bedroom door opens easily and guickly from the outside when locked 13 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) 13 EXCEPT per R310.2.1: at -grade escape windows— may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44" above floor to clear openin ; no steps under window allowed 0 SLEEPING ROOM C Type S JU Type NS1 I El Type NS2 YES NO Closet door/s are readily openable from the inside es jr3No ©N/A I Smoke alarm is installed in the bedroom 13 Bedroom door opens easily and quickly from the outside when locked 13 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) 0 EXCEPT per R310.2.1: at -grade escape windows — may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44" above floor to clear openin ; no steps under window allowed 13 SLEEPING ROOM D 113 Type S Type NSi JUType NS2 YES NO Closet door/s are readily openable from the inside 0 Yes 0 No �N/A Smoke alarm is installed in the bedroom 13 Bedroom door opens easily and quickly from the outside when locked 0 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) J3 E3 EXCEPT per R310.2.1: at -grade escape windows— may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowedl 1Z 0 SLEEPING ROOM E 10 Type S Type NSl 0 Type NS2 YES NO Closet door/s are readily openable from the inside Yes E3 No ON/A Smoke alarm is installed in the bedroom 13 0 Bedroom door opens easily and quickly from the outside when locked 0 Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) 13 EXCEPT per R310.2.1: at -grade escape windows— may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed 0 SLEEPING Type S Type NS1 0 Type NS2 YES NO XRO Closet door/s are readily openable fide E3 Yes Q No ON/A Smoke alarm is installed in the bedroom13 1 13 Bedroom door oreasily and q 'e outside when locked � 0 Sleeping room window has a opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) 0 E3 EXCEPT per R310.2.1: at-gr a escape windows— may have net clearance opening 5 SF Sleenine room window h s a maximum sill height of 44" above floor to clear opening; no steps under window allowedl 0 13 Implementation Date: 2021 February 01 Updated: 2021 February GENERAL Bathroom doors are easily and quickly openable from the outside when locked Carbon Monoxide alarms are installed as required in R315 on each level of the home. Smoke.afarm-arei,nAaon all levels of the dwelling, in each resident sleeping room, outside each separate sleeping area in the immediate vicinity of sleeping rooms (11314). Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all parts of the dwelling upon activation of a single device. Access road and water supply meet local fire jurisdictional requirements. R330.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping, pinching ortwisting of the wrist (lever -type). Pocket doors shall have graspable hardware available when in the closed or open position. 111311.8 Ramp Inside Ramp I N/A R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in R330.9) R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp changes directions. R330.9.1 Handrails required on both sides of ramp. Outside Ramp I N/A C3 R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in R330.9 R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp changes directions, R330.9.1 Handrails required on both sides of ramp. R312.1.1 Guards shall be located along open -sided walking surfaces, that are located more than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. Guards below are depicted vertically as an example only. Handrail both sides Less than 4" 34" - 38" Guard •• j' .. ,. .... .. � I 36" min i 3x 3' min landing S. - 3' — one unit vertical in twelve units horizontal minimum is an 8.3% slope all along surface of the ramp. Y E 5 NO 0 � iu UJAQ rim AQ ®m 0191 "•Heal vu 0U CHm En Tx 3' min landing 3' minimum Implementation Date: 2021 February 01 Updated: 2021 February R311.2 Means of Egress YES NO R311.2 Door must be side -hinged with min. width of 32 inches between face of door and stop. Height not less than 78 inches. R93'T4 pera`-We pater sofiljyorhandles;-pulls,-latches locks -and -other -devices -installed in-AFH shall•be•operable-with.ne^haad- 13 and shall not require tight grasping, pinching or twisting of the wrist I lever -type). R330.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry 13 without use of key, tool or special knowledge. R311.7 Stairways I N/A YES NO R311.7.5.1 Riser Height: Max riser height shall be 7 % inches (8 inches in structures built prior to July 1, 2004) R311.7.5.2 Tread Depth: Min. tread depth shall be in 10 inches (9 inches in structures built prior to July 1, 2004) 0 R330.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple 13 0 risers. Handrails shall be installed in accordance with R311.7.8.1— R311.7.8.4 R330.8 Grab Bars in Bathrooms IN/AI YES NO Grab bars shall be installed for all water closets (toilets), bathtubs and showers according to R330.8. Water Closets (toilet) shall have grab bars installed on both sides according to R330.8.3 Bathtubs shall have two vertical and three horizontal grab bars installed according to R330.8.4 1113 Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower according to R330.8.5 Shower stalls must be minimum size of 30 inches deep by 48 inches long,(R330.11) PASSED 19 NAME OF AFH: J� III ='✓t lJ 1, *D V LT' 36me- Cam' Adult Family Home Project Address 4— BUILDING DEPT. INSPECTOR'S NAME (PRINT) DEPT. INSPECTOR'S SIGNATURE *- U IkoL4 DATE: _ 3332S Si'` %ram S. Frp �- . ice. 253- BUILDING DEPT. OFFICE ADDRESS OFFICE PHONE NUMBER: Application and inspection checklist developed by Washington Association of Building Officials (WABO), in cooperation with Department of Social and Health Services iDSHS) for use by both departments and licensors in accordance with WAC 388-76-10700. Implementation Date: 2021 February 01 Updated: 2021 February �--'.IMCEIVED �c - _ L PERMIT APPLICATION Y'CEWTE 2024 Wy Of FERMI r,ITY OF FEDERALWO:, S:35 R)07 + 2")-83S--)b0') 4 j)rrn)-,cr,t- Federal WaY WNjMUNrrY DEVELOPMENT -7 SF PERMIT NUMBER TARGET DATE SUITE/IJNIT 0 rrTE ADDRIESS W4 1) �'.'�C��"ALIJATION .— ZONING ASSESSOR'S TAX/PARCEL 0, S TYPE OF PERMIT 0 BOLLAN0 FCHANICAL NAME OF PROJECT PROJECT DESCRIPTION L nied description 0j smelt to -M.-i. only vi -F br-- included on thus P Z v NAME -A- PRIMARY PHONE -e 'T A PROPERTY OWNER nL4ILIxc ADDRESS ilGf Ct CMSTSTATE ZIP IIAME ----------- . MAILING ADDRESS CONTRACTOR --------- CITY WA STATE CONTRACTOR'S LICENSE 0 NAME Z. STATE ZIP EXPIRATION DATE ",-UCANT MAILING A.DLDRESS STATE 24P CITY I VANE I C-Alf dAIA) PROJECT CONTACT (Tile indfuidual fo rece-ve and KAILING ADDBES's R H'Cv i C T- 2 x '2 respond in all mwrespofWence CITY C STATE ZIP appileawni NAME PROJECT FINANCING 1plen Lujue is 55, 000 or more MAILImr, ADDRESS, CITY, STATE, ZIP fRCV,f 19 27 095j 1 C- PHONE E-MAIL FAX UBI 4 pRIbLkRY PHONE MAIL C110'1f /G�—' FAX l t- LA>A4 PRIMARY PHONE E-MAIL 5�?IVA-A)UE-L kti-,'VV14�A. FAX ❑ OWNER -FINANCED PHONE I certify under penalty of perjury that I am the properly owncr, or, authorized agent of the PrOPOPW Owner- r certify that to the base of my knowledge, the Information submitted in support of this permit application is true and correct. I eeft(fy that r will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the Issuance of this perinit does not remove the Owner.1 responsibility for COMPli0"cc with Focal, stare, or federal laws regulating cq mst7ucejon or- environ men W laws. Ifurthcr agree to hold harmless the City Of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the Investigation and defense Of such clair4, which may he made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the rellaace of the city, Including Its officers and employees, upon the accuracy of the Infornuttia F3 supplied to - the city as a part of this applica tim SIGNATURE, PINT NAME; kf BuIlci-in #100 - February 19-2020 Page I of-2 Application