09-100631City of Federal Way ,Community Development Services P.O. Box 9718 Federal Way; WA 98063 -9718 Ph: (253) 835 -2607 Fax: (253) 835 -2609 F L--- 1"i C Project Name: FOOTLOCKER Project Address: 1928-B S COMMONS SUITE E -16 Project Description: New lighting circuits and power to new outlet. Electrical Permit #: 09- 100631 -00 -EL Inspection Request Line: (253) 835 -3050 Parcel Number: 762240 0010 Own r Applicant Contractor STEADFAST COMMONS LLC SURGE ELECTRIC INC SURGE ELECTRIC INC 1928 S COMMONS 13617 NE 61ST AVE SURGEEI922PG (10/7/10) FEDERAL WAY WA 98003 -6013 VANCOUVER WA 98686 13617 NE 61ST AVE VANCOUVER WA 98686 Service greater than 1000 Amps ? ...........................No FI ,. • THIS CARD IS T1W.MAIN ON -SITE CITY OF Community Development Inspection Record, Federal Way IVR INSPECTION REQUEST PHONE # (253) 835 -3050 PERMIT #: 09- 100631 -00 -EL Owner: STEADFAST COMMONS LLC Address: 1928 -13 S COMMONS SUITE E -16 FEDERAL WAY, WA 98003 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom).. Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. ❑ UFER Ground (4295) ❑ Ditch cover (4030) ❑ Slab /Concrete Floor (4255) Approved Approved Approved to place concrete By Date By Date By Date ❑ Pool Bonding (4195) ❑ Temporary Power (4275) ❑ Service (4235) Approved Approved Approved By Date By Date By Date ❑ ❑ ❑ Feeders /Sub - panels (4045) Rough Electrical (4225) Ceiling Cover (4020) Approved Approved Approved By Date By Date a _ _6I By 0 Date J ❑ Final - Electrical (4055) Approved By Date - -6 O 0 Rough Electrical Approved By Date For inspector reference only 13 FINAL - Electrical Approved By Date oly OF 4A 'OvECEIVE' hy 'COMMUMIYDBVBLOAMBM SBRVI� PE RM IT SF MF CO M L PL DE EN FP 3331FEWRM WAY, WTI, • P -9718 97�. A P PLI CAT I O N PSDBRAL WAY, WA 98063 -9718 / Y53- 835.1607• A - 835.2609 *F FEDERAL WAY The following is r'e4uireCl nation _ an incomplete application wilt not be aeceptsd. Phrase print tegibbj (in Wci or type• PROPERTY INFORMATION SITS ADDRESS �?/(.! l SUITE /UNIT # ASSESSOR'S TAX /PARCELf` %if S'� _ Sd� 6 — — — — — _ — — LOT SIZE (sp LEGAL DESCRIPTION (e.g. Acme Estates, Lot 1) , zl ml PROJECT INFORMATION TYPE OF PERMIT ❑ BUILDING ❑ PLUMBING Q MECHANICAL ❑ DEMOLITION ELECTRICAL ❑ ENGINEERING ❑ FIRE PREVEXITION SYSTEM PROJECT DESCRIPTION (Pro/vide detailed description of Mork included on tiers tom= onlu) CONTRACTOR APPLICANT PROJECT CONTACT LENDER .7� E PEOPLE INFORIIATION NAME PRIMARY PHONE MAILING ADDRESS CIfY, STATE, ZIP E-MALL ADDRESS AMP APPLICANT NAME OFFICE PHONE MAILING ADDRESS MAILING ADDRESS 3 -- %r CITY, STATE, ZIP y rf ,4 °rte >�, �' 4� _ CELL PHONE _ CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER EXPIRATION DATE /AX NUMBER C0FrRACTOA'8R=Un?AT/I0X X9K8�SR !� SI@O!A DATS E-MAIL ADDRESS COMPANY NAME APPLICANT NAME OFFICE PHONE MAILING ADDRESS CITY, STATE, ZIP CELL PHONE RELATIONSHIP TO PROJECT ❑ Architect ❑ Tenant ❑ Agent ❑ Other FAX NUMBER ( ) - NAME PRIMARY PHONE E-MAIL ADDRESS NAME Par RCW 19.27.095: ....,a..q Lender i#L&rn -don is • aZut ed #%p *-t veils! ows-is $4000 MAILING ADDRESS arr, STATE, ZIP PHONE ( ) - E�STING USE PROPOSED USE EXISTING ASSESSED /APPRAISED VALUE VALUE OF PROPOSED WORK SPRUfl(LERED BUILDING? ❑ YES ❑ NO FIRE SUPPRESSION SYSTEM PROPOSED /REQUIRED? O YES ❑ NO WATER SERVICE PROVIDER ❑ LAKEHAVEN ❑ HIGEMM ❑ TACOMA ❑ PRIVATE (WELL) SEWER SERVICE PROVIDER ❑ LAICFHAVEN ❑ HIGHLINE ❑ PRIVATE (SEPTICI AREA DESCRIPTION EBIS=G 3 . FT. PROPOSED SQ. FT. TOTAL SQ. FT. BASEMENT GAS WATER HEATERS MISC (Deembe) BOILERS FIREPLACE INSERTS FIRST COMPRESSORS FURNACES RANGES SECOND GAS LOG SETS REFRIG. SYSTEMS 3 THIRD a YES )<NO BATHTUBS (wTubjshwwComea► IAVS 9ia" ADDITIONAL FLOORS (DESCRIBE) DISHWASHERS RAINWATER SYST VACUUM BREAKERS DECK (❑ COVERED OR ❑ UNCOVERED ?) SHOWERS WATER CLOSETS (r.&q =,ZCTRW WATER HEATERS GARAGE ❑ CARPORT ❑ WASHING MACHINES HOSE BIBBS SUMPS NUMBER OF FLOORS 1�= PROPOSED TOTAL TWALAM Mar �oreersaroesosr Tamar "NEWROMES ONLY'" NUMBER OF BEDROOMS ESTIMATED SELLING PRICE $ Indicate number of each type of fudure to be installed or relocated as part of this project. Do not include existing f"tAM to remain. %due of Medutnical Work .$ (A C OF Bm OR ESTIMATE MUST BE INCLUDED %TMAPPLICATIONJ AIR HANDLING UNITS EVAPORATIVE COOLERS GAS PIPE OUTLETS WOODSTOVES Saw FANS GAS WATER HEATERS MISC (Deembe) BOILERS FIREPLACE INSERTS HOODSIcoem.�tq COMPRESSORS FURNACES RANGES DUCTS GAS LOG SETS REFRIG. SYSTEMS 3 NEW ADDRESS REQUIRED? a YES )<NO BATHTUBS (wTubjshwwComea► IAVS 9ia" URINALS MISC, (Describe) DISHWASHERS RAINWATER SYST VACUUM BREAKERS DRINKING FOUNTAINS SHOWERS WATER CLOSETS (r.&q =,ZCTRW WATER HEATERS SINKS WASHING MACHINES HOSE BIBBS SUMPS Z car ft Fj muter penally of perjury that Z mn the properly ow— or mduetzed agent of the property owner. Z aw t(& that to the best q/ my knowledge, the information submitted in support of this permit application is true and correct Z certify that Z will comply wtth all applicable City of Federal Way regatUdions pertaining to the work authorised by the lasuance of a permit Z understand that the issuance of this permit does not remove the oamses responsibility for compliance with boat, state, or federal taws reguZuting construction or environmental lanmt Z further agree to hold harmless the City of Federal Way as to any claim (including costs, aepenses, and the atto ragas' Jens incurred ire tnwsIIgation and defense of such claim), which may be made by any person, including the undersigned, and fitsd against the city, but only where such claim arises out of the reliance of the city, including its o leers and employees, upon the accuracy of the h4formation supplied to the city as a part of this Ucatio SIGNATURE• DATE G Property Owner and /or Authorized Agent a NEW a ADDITION a ALTERATION a REPAIR ktENANT IMPROVEMENT BUILDING SHELL ONLY? a YES ArIfo BASIC PLAN? )e-Yw a NO ZONING DESIGNATION CHANGE OF USE? a YES O NEW ADDRESS REQUIRED? a YES )<NO IIP /SEPA /SII? a YES O Z. PLATTED LOT? a YES ENO DEMO PERMIT REQUIRED? a YES _I�fNO Bulletin #100 January 1, 2009 Page 2 of Mandouts\Permit Application an automation fee of $6.00 will be charged for all permits. RESIDENTIAL COMMERCIAL NEW RESIDENTIAL SERVICE NEW COMM MULMMUSTRIAL SERVICE ❑ Single Family Square Feet Service or Feeder Each Add'n (First 1300 m- $121.00; each add n 500 W , $39.00) ❑ 0 to 100 amp $131.50 $ 80.00 ❑ Detached outbuilding or garage (/service) ......................... $51.00 ❑ 101- 200 amp 163.00 103.00 ❑ 201- 400 305.50 120.50 ❑ Detached outbuilding or garage (inspected separately) $80.00 amp ........ • swimming pool (./.vice) ........................ $80.00 ❑401. -600 amp 356.00 142.50 ......................... • swimming pool ( inspected separately) ............................... $120.50 ❑ 601 - 800 amp 460.50 195.00 ❑ 801 - 1000 562.50 235.50 • Hot tub /spa sauna (w /service) ................. $51.00 amp ......................... ❑ Hot tub /spa /sauna (inspected separately) .......................... $80.00 ❑ Over 1000 amp 613.00 327.00 ❑ Sept pumping system (-/ service) ............ ......................... $51.00 ❑ Over 600 volts surcharge $103.00 ❑ Sept pumping system (inspected separate ly) ..................... $80.00 ❑ Mast or meter repair $111.00 NEW MULTI- FAMILY (three units or more) ALTERED COMMERCIALMIDUSTRIAL (Does not include circuits.) Service Feeder ❑ Up to 200 amp $131.50 $ 39.00 Service or Feeders ❑ 201 - 400 amp 163.00 80.00 ❑ 0 to 200 amp $131.50 ❑ 401 -600 amp 223.00 111.00 ❑ 201 -600 amp 305.50 ❑ 601 - 800 amp 285.50 152.50 13 601 - 1000 amp 460.50 ❑ Over 800 amp 408.50 305.50 13 over 1000 amp 513.00 ❑ J__Z# of circuits to be added /altered ALTERED 8II�GLE /MULTI FAMILY (1-5 circuits - $103.00; Add'n circuits, $8.00 /ea) Service or Feeder CONMOMIAWINDUSTRUL PLAN REVIEW ❑ 0 to 200 amp $100.50 $103.00 plus 35% of Permit Fee ❑ 261 - 600 amp 163.00 ❑ Service - 1,000 amps or greater ❑ over 600 amp 245.50 ❑ Medical /Educational /Institutional Facility ❑ Additional plan review for ❑ # of circuits to be added /altered modified submittals $115.00 /per hour (1-4 circuits - $80.00; Add'n circuits $8.00 /ea) ❑ Mast or meter repair $60.50 TEMPORARY SERVICE Service or Feeder Each Add'n MANUFACTURED HOMES • Service or feeder only $80.00 C3 0 to 60 amp $ 71.00 $32.00 ❑ 61 -100 amp 80.00 39.00 • Service and feeder $131.50 ❑ 101- 200 amp 103.50 51.00 ❑ 201 - 400 amp 120.00 60.50 MOBILE HOME /RV PARK ❑ 401- 600 amp 163.50 80.00 ❑ # of service or feeders ❑ Over 600 amp 183.00 92.00 (First service /feeder - $80.00; each add'n - $52.50) MISCELLANEOUS SERVICE /EQUIPMENT ❑ # of Thermostats (First - $60.50; add'n- $18.50/ea) ❑ # of Signs ❑ Low Voltage (First sign- $60.50; add'n sign $28.50/ea) Square Feet to be served by system(s) ❑ Yard Pole /meter loops /pedestal ................... $80.00 ❑ Fire Alarm system ❑ Portable Generator (transfer equipment) ...... $100.50 ❑ Security Alarm system ❑ Voice Cabling ❑ Ditch cover /inspection only ....................... $120.50 ❑ Data Cabling ❑ 19, 2500 0471.00; For fees not listed, contact the Permit Center at Each add'n 2500 ft?- $18.50) 253- 835 -2607 Bulletin #100 -January 1, 2009 Page 3 of 4 k\Handouts\Permit Application