Loading...
12-101799h r r ' ` &ilding - Single eFa ily` City of Federal Way Community & Econ. Dev. Services 8 7. Permit #. 12 -101799 -00 -SF 33325 8th Ave S Federal Way, WA 98003 1 Ph: (253) 835-2607 Fax: (253) 835-2609 Inspection Request Line: (253) 835-3050 Project Name: FAULKNER Project Address: 2022 S 282ND PL Parcel Number. 4222310140 Project Description: ADD - Construction of 651 square foot detached garage. No plumbing or mechanical. Owner Annlicant Contractor Lender BENJAMIN D FAULKNER BENJAMIN D FAULKNER OWNER IS CONTRACTOR OWNER IS LENDER ANGELA FAULKNER 2022 S 282ND PL 2022 S 282ND PL FEDERAL WAY WA 98003 FEDERAL WAY WA 98003 Census Category: 438 - Residential Garage or Carport Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load Floor Areas . ft. 0 0 0 0 Additional Permit Information New / Additional Sq. Feet - 1 st Floor .................... 0 New / Additional Sq. Feet - 3rd Floor....................0 BasicPlan?........................................................... No New / Additional Sq. Feet - Garage .......................651 New / Additional Sq. Feet - Other..........................0 New / Additional Sq. Feet - Total .......................... 651 New / Additional Sq. Feet - 2nd Floor...................0 New / Additional Sq. Feet - Basement...................0 New / Additional Sq. Feet - Deck..........................0 Mechanical to be Included?....................................No Plumbing to be Included?......................................No Zoning Designation................................................RS 7.2 No Fixtures Associated With This Permit it PERMIT EXPIRES Wednesday, December 5, 2012 Permit Issued on Friday, June 8, 2012 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington a City of Federal Way. / Owner or agent'��/aoo�Date: l� �� ONO (Vm4wrz d M, of Federal Way THIS CARD IS TO REMAIN ON-SITE Construction I ection Record INSPECTION REQU TS: (253) 835-3050 PERMIT 4: 12 -101799 -00 -SF Address: 2022 S 282ND PL Project: BENJAMIN D FAULKNER FEDERAL WAY, WA 98003-3241 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. SWM Precon Site Mtg 4400) Initial Krosion Control (4365) Footings/Setback (4110) Approved To be done prior to breaking ground Approved to place concrete By Date do By Date By /�f Date g-1-1.7, o Foundation Wall (4115)0 Drainage/Downspout (4040) 0 Slab/Concrete Floor (4255) Approved to place concrete By Approved to backfill Approved to place concrete By Date By Date By Date ❑ 0 Floor Sheathing (4105) 0 Underfloor Framing (4285) Shear Walls (4245) Approved to sheath floor Approved to install flooring Approved to install siding By Date By Date By Date ❑ 0 Roof Sheathing (4220) 0 Fire/Draft Stops (4095) Interim Erosion Control (4370) Approved to install roofing Approved Approved By Date By Date By Date Prior to scheduling a Framing inspection; Framing (4120) Insulation (4150) Electrical, Plumbing & Mechanical Rough -in and Approved to insulate Approved to install wallboard Fire/Draft Stop inspections must be signed -off and approved. IBC 109.3.4 Bye Date (Z SU 3 By Date ❑ Gypsum Wallboard Nailing (4130)Final ❑ Erosion Control (4375) Final - Building (4050) Approved to install mud & tape Approved Approved By Date By Date By V_Y3 Date I Z I 2 -to 7 Rough Electrical Approved Final Electrical Approved Right of Way Approved By Date By Date By Date , `'PERMIT cin of Federal Way.., V COMMUNITY DEVELOPME� !•A P P L I C A T I O N -8 25335-2607• ,,,x25 3 9 www.rftuof(ederalwau.roa, apR o,� Q2,- 0LI? f— MF CO ME PL DE EN FP /1 4 a.g SITE ADDRESS SUITE/UNIT B T PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL ! TYPE OF PERMIT b BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT (Tenant Name/Homeowner Last Name) PROJECT DESCRIPTION Detailed description of work to LIVI be included on this permit only PROPERTY OWNER l` L PRIMARY PHONE 10 91 MAILING ADDRESS / Re i Q 4zne CITY STATS ^' e,'L'V U/ V NAME PHOIM MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE M EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE N NA17 Ile PHONE APPLICANT MAILING ADDRESS E-MAIL CITY STATE ZIP FAX PROJECT CONTACT NAME }� PHONE (The individual to receive and fir. �A''ol MAILING ADDRESS E-MAIL respond to all correspondence concerning this application) CITY STATE ZIP FAX ALTERNATE CONTACT NAME: PHONE E-MAIL PROJECT FINANCING NAME Q OWNER -FINANCED Required value of $5,000 or more MAILING ADDRESS, CITY, STATE, ZIP PHONE (RCW ]9.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with Iocal, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. SIGNATURE: DATE PRINT NAME: Bulletin #100 —January], 2011 Page 1 of k:\Handouts\Permit Application ZP,4-- VALUE OF MECHANICAL WORK $ FIRST FLOOR (or Mobile Home) (a copy of bid or estimate must $eo.'prouided) Indicate how many of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS( BOILERS FURNACES `HOT WATER TANKS (G') COMPRESSORS GRSJQG SETS REFRIGERATION SYST DUCTING GAS PIPIN WOODSTOVES Area Totals I EXISTING PROPOSED TOTAL Indicate how many of each type re to be installed or relocated as part of this ect. Do not include existing fixtures to remain. BATHTUBS (or7wb/Shower ) LAV S (Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS (Kitchen/Utility) WATER HEATERS (Electric) HOSE BIBBS SUMPS r � WASHING MACHINES(, 'x 1'TION AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE FIRST FLOOR (or Mobile Home) 15!SECOND FLOOR COVERED ENTRY DECK GARAGE Ly CARPORT ❑(ncz;)� -- — -- — -- OTHER (describe) Area Totals I EXISTING PROPOSED TOTAL "NEW HOMES ONLY" ESTIMATED SELLING PRICE $ 1 # OF BEDROOMS W AREA DESCRIPTION Area Occupancy Group(s) Construction # of Additional Information in Square Feet Type Stories NEW BUILDING `. ADDITION _rmww,CO-NIMERCIAI.: — RE,NIOi)EI./TEN ANTI A�1,PIZOVFMFI. TS Area Construction # of AREA DESCRIPTION in Square Feet Occupancy Group(s) Typa Stories Additional Information TOTAL BUILDING TENANT AREA ONLY PROJECT AREA ONLY: " r Bulletin #100 — January 1, 2011 Page 2 of 3 k:\Handouts\Permit Application Revisions PLOT # 422231-0140 - ADDRESS 0 N M-/ Mm a.-- . 2022 282ND PS L 7` FEDERAL WAY WA 98003' GARAGE LEGEND TOTAL SQ FT OF LOT 8895 ® TREE — FENCE DRAWN BY: ROCKERY BENJAMIN FAULKNER O HOUSE 6 O PURPOSED BUILDING SCALE: CEMENT BLACKTOP 3/16 — 1 GROUP: SITE PLAN VY DATE: March 21, 2012 196SQF _ CONCRETE PURPOSED t GARAGE SITE Existing house �.� LIST OF ALL EXISTING KEY PLAN IMPERVIOUS AREA NOTES: HOUSE 1431 SQ FT POWER DRIVEWAY 283 SQ 1431 SQ FT \ .651 SQ FT ,`) FT PATIO 196 SQ FT \5 ALL PURPOSED IMPERVIOUS AREA SEWER\ --_-_ --- _-- GARAGE 651 SQ `� ------- FT 283 SO ��✓ C`��io BLA TOP 003 avp A Cb, 5 � Ser plc WATER