Loading...
10-103556City of Federal Way Community Development Services P.O. Box 9718 Federal Way, WA 98063 -9718 1?h^ (253) 835 -2607 Fax: (253) 835 -2609 Sign Permit #: 10- 103556 -00 -SG Inspection Request Line: (253) 835 -3050 Project Name: WELLS FARGO Project Address: 2505 S 320TH ST SUITE 640 Parcel Number: 797820 0535 Project Description: Installation of internally illuminated cabinet sign on existing framework. Includes electrical connection to existing J -box. Owner Aoolicant Contractor WELLS FARGO ICON IDENTITY SOLUTIONS TUBE ART DISPLAYS INC (GENERAL) 2505 SW 320TH ST SUITE 640 1415 ELMHURST RD TUBEAD *311 QS (6/30/12) FEDERAL WAY WA 98003 ELK GROVE VILLAGE IL 60007 2730 OCCIDENTAL AVE S 3.40 Fast SEATTLE WA 98124 -1333 Comprehensive Reg. # Sign Type ;: Illuminated # Sign Faces Sign Face Width (Ft) Sign Face Height (Ft) Building Elevation 10 -0117 Cabinet Yes 1 40.00 3.40 Fast PERMIT EXPIRES Sunday, March 20, 2011 Permit Issued on Tuesday, September 21, 2010 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington the City of Federal Way. Owner or agetit-;._—�� Date: /I Z21 -J t/9410 THIS CARD IS TO RP SIN ON -SITE Construction T5 aRecord Fed INSPECTION REQUESTS: (2 PERMIT #: 10- 103556 -00-SG Address: 2505 S 320TH ST SUITE 640 Owner: WELLS FARGO FEDERAL WAY, WA 98003 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. Attachment (4010) Approved By Date t- Footings /Setback (4110) ❑ Final - Electrical (4055) Final Electrical Approved Final - Sign (7aLL Approved to place concrete By Approved By Approved By Date By Date , By Date ,—I Attachment (4010) Approved By Date t- Rough Electrical Approved Final Electrical Approved Right of Way Approved By Date By Date By Date Aug DS 2010 1 j EIVED 2532375009 P.1 AUG 18 29M �ITY OF FEDERAL WAY Federal Way CDS SIGN PERMIT APPLICATION _Z0 -1I 3���_L0 F// AseaaRO S TAZIPAROEL d '. g --I JF- JS- 0— - 4 h -a- 5 Zomma ampuTUm TTPE 61 PROJECT (Cheek sL that e": D NEW KALTUATIOR c RWACB a ZIEWPT TRiOAL rib attach to wd%ttng J -box - Include on thle paMaM D MACTSICAL (NeM /altamd choult d J-box added - aapersta permit Is rmgUkMd) WMlVZROFS =AAPp=POKwlTETWBAPPLJCATloM WalU mnWi '1- kmdwwlnC1_ TOTAL E&VIOUTZD PROJECT COSTI 8 MXTAAMD PAOJZCT M0cRO?nOW lql\ Qn Ne -s L S,ft-N 5 f1+yQ ww owb, : APPUMM Nnwcl -5e11b e eeuu+v Fume - F MAL040 ADOPoISS PTKWrADDRV t Q1V. W=M ZIRA ► ►AY aumeat Cafor a{IMW.MeYWI8N6Ea 11CYt36 Im L tidWL AOORM "7-706- O CM 1W MMIMLININ Wl4Me , WHOM FD90M ZKPMATi DAR FAY FticR NRR flBomw A90N NA"Xfl! 8104mm DMMet 9-Mw A=MM MANY NAME APFLCAW NAUL PFNARYFiONC hWLAW ADDRM CD i M. GUTL LIP NIBParA S , v Mic oatAlmom IRMOrRwom - FAIAIL ADDRIBB D C4nkaMDr D Tenant Q ORler PAW= rMWLAbDlK*ft CONTAOT �. — tf ) - qtr A. re 'A. c I emrtW under peadty of pe*V teat Rte IhImmo tlm, emsdra ttR aea lm seas sad ear . to Ike bast d mP kaaadad`e. and tLetieq tkes i am aatiwllaad>'P t19e owaar oitaa Rta'ra peaadna•se puts "am Ate work dor arkluh am permit apptsatlea in male Dam T. 5--Ay tD Mmbojwm DwAvApmFln'a mom.333"SmAvsms SoMm -POBOX OHS.rtOMM4 MAY. WA M554P1A- X389e- 98lr-rAX 2ee-62 d MANY NAME APFLCAW NAUL PFNARYFiONC hWLAW ADDRM CD i M. GUTL LIP NIBParA S , v Mic oatAlmom IRMOrRwom - FAIAIL ADDRIBB D C4nkaMDr D Tenant Q ORler PAW= rMWLAbDlK*ft CONTAOT �. — tf ) - qtr A. re 'A. c I emrtW under peadty of pe*V teat Rte IhImmo tlm, emsdra ttR aea lm seas sad ear . to Ike bast d mP kaaadad`e. and tLetieq tkes i am aatiwllaad>'P t19e owaar oitaa Rta'ra peaadna•se puts "am Ate work dor arkluh am permit apptsatlea in male Dam T. 5--Ay tD Mmbojwm DwAvApmFln'a mom.333"SmAvsms SoMm -POBOX OHS.rtOMM4 MAY. WA M554P1A- X389e- 98lr-rAX 2ee-62 d PAW= rMWLAbDlK*ft CONTAOT �. — tf ) - qtr A. re 'A. c I emrtW under peadty of pe*V teat Rte IhImmo tlm, emsdra ttR aea lm seas sad ear . to Ike bast d mP kaaadad`e. and tLetieq tkes i am aatiwllaad>'P t19e owaar oitaa Rta'ra peaadna•se puts "am Ate work dor arkluh am permit apptsatlea in male Dam T. 5--Ay tD Mmbojwm DwAvApmFln'a mom.333"SmAvsms SoMm -POBOX OHS.rtOMM4 MAY. WA M554P1A- X389e- 98lr-rAX 2ee-62 d A ■ TYPE OF SIGNjS) (Indicate number of each) PFANLANENT FREE STANDING: • 1 .. Ji DZ8TAL -POLE TENANT DnU=ORY OTHER OTHER (Descrlbl� PERMANENT BUILDING MOUNTED: _AWNING ( CABINET CHANNEL LETTERS TENANT DIRECTORY OTHER (Describe) ■ DETAILED SIGN INFORMATION FREE STANDING SIG WILDING MOUNTED SIBEI S SIGN TYPE SIGN AREA (SQ. FT.) ILLUMINATED REFACE? TOTAL HEIGNI BASE HEIGHT (FT) AREA PROPOSED:_ WIDTHxHEIGHTZROFFACES NO tINT EXT YES I NO • FT. A A 315„ x �t x = �3, LAND USE APPROVAL BYs DATES Y L 0 STRUCTURAL APPROVAL BY: DATE: 35 7 B REGISTRATION NUMBERS REGISTRATION N REGISTRATION NUMBERS REGISTRA ON NUMBER: x x = REGISTRATION NUMBER: R TION Human: r.. C x x x = C D x E STREET FRONTAL NEAR FEET): X x = /J LARGEST EXPOSED BUILDING FACE (SQUARE FEET): :/ BUILDING MOUNTED SIGNS WILDING MOUNTED SIBEI S FREE STANDING SIG S SIGN TYPE SIGN AREA (SQ. FT.) ILLUMINATED? BUILDING ELEVATION EXPOSED BUILDING FACE AREA PROPOSED:_ WIDTH x HEIGHT x G OF FACES NO INT EXT N W • FT. A / 315„ x �t x = �3, LAND USE APPROVAL BYs DATES Y L 0 STRUCTURAL APPROVAL BY: DATE: 35 7 B REGISTRATION NUMBERS REGISTRATION N REGISTRATION NUMBERS REGISTRA ON NUMBER: x x = REGISTRATION NUMBER: R TION Human: C x x = D z x — E X x = /J LARGEST EXPOSED BUILDING FACE (SQUARE FEET): :/ wens a Pw aatas eun vss I i / /', ZONING DESIGNATION: Cr - PROFILES ❑ HIG IUM ❑ LOW ❑ FREEWAY WILDING MOUNTED SIBEI S FREE STANDING SIG S AREA PERMITTED: Yb AREA PERM AREA PROPOSED:_ AREA PROPOSED: LARGEST WILDING FACADE: � � BEET FR NUMBER OF SIGNS ALLOWED' NUMBER OF SIGNS ALLOWED: / LAND USE APPROVAL BYs DATES Y L 0 STRUCTURAL APPROVAL BY: DATE: REGISTRATION NUMBERS REGISTRATION N REGISTRATION NUMBERS REGISTRA ON NUMBER: REGISTRATION NUMBER: R TION Human: Bulletin 5102 -April 9, 2010 Page 2 of 4 lufHandouts/Sign Permit Application 8 -10 -10 Icon Identity Solutions Sht. t of 3 File: IconIdentSolut904.mcd Site: Wells Fargo Home Mortgage Location No. 1805 2505 South 320th Street Suite 220 Federal Way, Washington 98003 FYr_E Sign Type: 3' -5" x 40' -0 1/2" overall length x 9 -1/2" deep single face sign band consisting of two ( 2 ) cabinets. One at 18' -0 5/8" in length, the other 21' -11 3/8" for installation on existing steel angle frame. Drawing No. WEL0400A sheets I and 3 of 3. Design loads are based on the Washington State Building Code ( 2006 IBC ) using Exposure C and 90 mph winds. Design Wind Speed : ( mph. ) V:= 90.0 Importance Factor: 1:= 1.00 Based on Category II, Non - Hurricane Prone Regions with V = 85 -100 mph. Velocity Pressure Coefficent at a Height of Less Than 80', Exposure C : Kz = 1.21 Topographic Factor: Kzt := 1.00 Based on 6.5.7.2 Wind Directionality Factor: Kd := 0.95 Based on Table 64 Velocity Pressure: ( PSF) qz:= 0.00256•Kz•Kzt•Kd• V2•I qz = 23.836 Force Coefficent : Cf = 1.65 Based on Figure 6 -21 Gust Effect Factor: G:= 0.85 Taken from 6.5.8.1 for Rigid Structures Design Pressure: ( PSF ) F = gz•Cf•G F=33.43 Use : WL := 33.5 Design Snow Load: ( PSF ) SL := 20.0 Based on Ground Snow Loads. Reference: Manual of Steel Construction, AISC 13th Edition. Mounting Bolts : ASTM A -36 Fu = 58.0 ksi. ; Ft =19.14 ksi. ; Fv = 9.90 ksi. ( Threads included in shear plane. ) Design Loads for the 18' -0 518" Sign Section: Shear from Dead Load: Based on 7.51bsJsq. ft.: ShDL := (3.42.18.05)•7.5 ShDL = 462.983 lbs. Shear from Wind Load ` : 9 -1/2" Deep Cabinet: ShWL := 118.05•( 92 )]. WL ShWL = 478.701 lbs. Shear from Snow Load: 9 -1/2" Deep Cabinet: ShSL := L18.05•I 9 =5 H.SL ShSL = 285.792 lbs. W_LE U�� xa D,t, •p 24275 O Ci �`sf ONAL EXPIRES: %� 15 / a.Ol� 12 Combined Shear Summation: ShTot :_ (ShDL + ShWL)2 + (ShSL + ShWL)2 ShTot = 1212.937 lbs. ESUBMITTED Design of Mounting Bolts for 18' -0 518" Sign Section : S E P 0 1 2010 Mounting -Bolt Diameter: (in.) MntBltDia:= 0.375 CITYOF FEDERAL WAY BUILDING DEPT. 8 -10 -10 Icon Identity Solutions Sht. 3 of 3 Design of Mounting Bolts for the 21' -11 3/8" Sign Section: Mounting Bolt Diameter: ( in. ) MntBltDia = 0.375 Number of Mounting Bolts in Shear: NoShr := 12 Shear per Mounting Bolt: ( lbs.) ShrWtBlt := ShTot ShrMntBlt = 122.918 NoShr Shear Area : ( in ?) ShrArea := 7c.0.33442 ShrArea = 0.088 ( Based on basic pitch diameter per AISC 4 -3 ) 4 Allowable Shear: ( lbs.) AllwShr := 9900•ShrArea AllwShr = 869 Unity Check - Shear: UCShr := ShrMntBlt UCShr = 0.141 < 1.00 OK AllwShr Number of Mounting Bolts in Tension: NoTen := 6 Minimum Distance Between Mounting Bolts : ( in. ) LvrArm 15.0 Tension Load per Mounting Bolt : ( lbs.) TenMntBlt := (ShTot)•(9.5) TenMntBlt = 155.7 NOTen•LvrArm Tension Area : (in.2) TenArea := n MntBltDga TenArea = 0.11 ( Based on nominal diameter per AISC 4 -3 ) 4 Allowable Tension: ( lbs.) A11wTen := 19140•TenArea AllwTen = 2114 Unity Check - Tension : UCTen := TenMntBlt UCTen = 0.074 < 1.00 OK AllwTen Unity Check - Combined: UCComb UCShr + UCTen UCComb = 0.215 < 1.00 OK Note: Use 3/8" diameter ASTM A -36 bolts. RESUBMITTED SEP 0 1 2010 CITY OF FEDERAL WAY BUILDING DEPT. Wells Fargo Federal Way, WA Sign Support Structural Calculations December 17, 2010 Prepared for: TubeArt 1705 4th Ave S Seattle WA 98134 (206) 223 -1122 Prepared By: Samir Chudgar, P.E., S.E. Chudgar Engineering Company 16230 NE 25th St Bellevue, WA 98008 RESUBMITTED (425) 881 -8979 DEC 2 1 2010 CITY OF FEDERAL WAY BUILDING DEPT. CHITDGAR ENGINEERING COMPANY sheet 'y of + Job No. 622 Project W alms FRf&I ` FfDIEQA-., Date Subject st) PP a el By SL (;�Ol QV Lt U LRl . V F.ST &,�J Check W l�010 Loki) �trkd Srcu d V gS gyp►. ak� 6t fpdclmo WaY �� �oswc -e, � • �3 g" A �a 2102 � pD V a � ` T 4_ p„r .r iiw-6�Z Psi. Wc� 1@6 w.a,o , V � 4 vkk- � WV-n ww"a Mukr> wqcozvs itA NW & W Q-%. �5 e k%A-SQA ^MO.)C w\wrp v*A W-^^ UQ� K,Tw� 2S 0p CHUDGAR ENGINEERING COMPANY Sheet _-l— of Job No. Project wt. l k, IrOu''(1 o Date Subject By SL Check F-Y� It sS 21c'L x b sow- SZ. o- bb S V ve 140 tb -X i of 66LZ SS0 1 bba A 1 low &t R L 9t wA I A moo. '��e P� �t2 �b z �,, o� b b F7 a ©' b6 4 2 b� 21 •7L jam. bx rt Z 2,S * 25,,E 1, of ` ll 7 /1* ate. - Acc e-ptu,66- f • WELLS FARGO . t LOC #349-1805 2505 S 320th St Federal Way, WA 98003 Contents Site Plan Pg. 1 Overview Photos Pg. 2 Signage Specifications Pg. 3 icon IG��[i[y SOIu LAG n3 k 40 0 1 1 -3 k" t9 m Varkcal stlppats Po _e WELLS FARGO HOME M MORTGAGE SIGN art ° ° E END Si Elevatwn /Custom Sin Face Building Sin n n t S 324' plywood — INSTALL ONE (1) ILLUMINATED SIGN PROVIDED BY OTHERS 2 x 8 beams — Vertical support • Material: m members White translucent acrylic with kiss -c 3 318" x 6' Ng — vinyl. s screws - One Red Block: p per bracket 3M Scotchcal Translucent Film 3630 -83, Regal Red Roof ntumbrane Black Block III Dropskadows: tort ca g ]t on to i m Black Blockout Matte 'YELLS FARGO• and Bar. 3M Scotchcal Translucent Film 3630, Custom Yellow VOO M Match d5 'Hone Mrsrtgye'. 3M Scatchcal Translucent Film 3630 -20, White Current conditions Phom inlay simulall %, o ;, a -,rr - ':5' x 1 %z" plated ooh nut washers one (1) top and one It l bottom at each pares ckp — 2 x 2' square tube support brackets - 2 x 2' angle clips Welded to parapet hangers 2 x 2' angle clips continuous angle across backside or sign — r P96 By__ t Date )? I r 11 14* 2. 11 II 2 Section (�_ Parapet Wall / Hananin Bracket Detail scale. = r-a I 6" c U c Q w N i+6 o + +1 Abm 64MU ] 2610 I 1 ]A ...... ar t..wart ne.e.vna - 1 ]x e... /w"\cLoomm2are ..e ialaslcW.Hfs14,.. ■ HOME tav +e m.zo.ta w.bnrc0•b.ttle•enn¢ MORTGAGE lell.le �y..ms f.em T..Oa4tbww 1 1 u.te.te6nc6.e e....i TUBE ART GROUP naw6wem raq. Nx eS rts s...r. • +lua,d Soy S)etnu -- _. _. _. etyma enm wq net uea.a+u. hee.alwq we �.Mu .iwuNc •. el.n - RESUBMITTED DEC 2 1 2010 CITY WAY LDING DEPT. FILE IL; 1 O 1 FILE IL; 1 O 1 r ' I t , . . I . 4 4 r 1 N.T.S. LEGEND AMN CODES TT N- s R = REPLACE ACTION /] 1 AG7 - � Y = REMOVE PH070 = C = CILSTOM SIGH = L = LEAVE N —NEW 1ZVIViLim MORTGAGE 2505 S 320th St SITE PLAN ' FN,E: WE- a 07(16109 WALE: As Noted ■W09OWT APPROVAL NOTUVA ION Please review are piacemens shown to determine ales compalibday with the conditions of tie location in wtdch the pm0ict is M de installed arid rote any changes lour signature will be consabWmd as your approval of the diummlailS shown as accuraW and acceptable for those conaftres. The ador5. Na and graphics shown an this page have been developed from artwork and intarmaaon supplied by WWk Fargo. Please review ahem carefak to delerrtdrr: Iheir accuracy and rote any changes required before your approval, as the pmlectwil be prod"a as approved. .e apps,,, naa aeva receivea. 'Aeihs Fargo will at held 'ma-,cau, espannbte lot any additional changes or adjustments to tho recommendec Prepaymcnl will be required lot such changes. aaaW Vno r dery 0APperd ry cswryr nobd OAWGraeet Bolo J APP,cro d r dew 0A"rwed W Chooee ft"W CUSTOMER NOTE SICNAGE WILL BE MANUFACTURED A SWPEO MY AFTER PERMITS ARE OBIAXED FROM. SUBCONTRACTOR. THE LOCAL CONTACT IS RESPONSIBLE FOP. PRIMARY ELECTRICAL SERVICE 1"0 TFUS LOCATION. IF ANY EXISTS. ALL OLD 31"S WILL BE REMOVED AND DISCARDED. TeGLIKi1 wlld:: RCQLL1:t0 d YES, ph ua iRdl:ale vitech RIP OV APPROVED L:'/ RECEIVED AUG 18 2010 CITY OF FEDERAL WAY CDS 0 v D -0 D ;;Q O rn 00 Ell L M n Cn cx) M cN o cc r O O tan j cn o > r) 001na mac% oo� O� D° � y 0 iT A 0 h8 :a 1 _— - PXL; 2 Psab 2 ?� 'a t Puts MIDI Pwtc 1 Pbb 18 Pnc:: 1 Pbdu 11 Pg. :c 1 Pbcb 12 HOME 1DcAum #349 -1805 OVERVIEW PHOTOS PILE: 349- 1805.cdr PAW 2o13 REwsm: 09/17;09 T1 -< . __ __ icon lJlti f!siGrcw /W MORTGAGE 2505 5 320th 51 DATE: 07r 16/09 scuE: As Noted u� v n.v1 _..1... ...... _. _... Federal Way. WA 98003 DRAtYY 71 DWECIOA: Sign #1 - EXISTING PHOTO l I Sign #1 - PHOTO ENHANCEMENT SA 6 zrat as S.F. ILLUMINATED WALL SIGN 31cF; 5' QTY. 1 SCALE- 1; 51 c, N 3,r t,d' SIDE VIEW NOTES: Home Mortgage -Wall Sign - Horizontal Internally illuminated, single sided Pan - formed dimensional letters in the red block area. Yellow letters and black dropshadow to be applied to raised face of letterform. Returns to be red. Black block area will maintain the "pushed back" profile. Attachment inspection required provide access for inspection prior to covering Material: witfl face panel • White translucent acrylic with kiss -cut vinyl. Red Black: 3M Scotchcal Translucent Film 3630 -83, Regal fled Black Black 8 Bropshadews: 3M Scotchcal Light Control Film 3635 -226, Black Blackout Matte "WRU FARGIr aad Bac: 3M Scotchcal Translucent Film 3630, Custom Yellow V1189IX1 Match a5 "Hone 11110""lle ": 3M Scotchcal Translucent Film 3630 -20, White Before the face panel can be Opproved for cover, electrical work require$' a separate Final Electrical (4055) inspe ion request. This is in addition to the A chment (4010) inspection request. ��4i ,�t k-f— 1 Approval Signatures. Date HOME Loclam` #349 -1805 SIGNAGE SPECIFICATIONS FILE: - 349- 1805.cdr PAGE: 3 of 3 REVISED: 09!17109 TI r— - __ —__ — __ a 7418 flmhura Ad MORTGAGE s sxlm St DH�WH: D71r> D9 DIE:aH As Noted _ icon rle cr.,, r;if r. -- urM�r; xos Federal Way, WA 98003 fl /^ a f,� v A 3 1 I 2 I 3 I 4 18' -0 5/8" I 50 iln V-3 7/8° C\\\; %\\;' U�� LE ° 65 90 1 1/4" 3 1 2" CABINET #1 53 54 40 &ELEVATION 53 � � SCALE: 1 /4 " =1' -0" AREA /WEIGHT THIS SIGN To DESIGN LOADS ARE BASED ON THE SIGN SQUARE FOOTAGE: BEAR THIS MARK WASHINGTON STATE (2006 BC) USING EXPOSURE C AND ESTIMATED SIGN WEIGHT: ®IAMAM'IEA.• 90 MPH WINDS. 1025 Lbs ELECTgIG BI(3M B NOTES SCALE: N/A 40' -0 1/2" 1/2" 21' -11 3/8" C S2 ELECTRICAL EXISTING 2" X 2" LAMPS 15 F96T120CW HO 3 F36T120CW HO BALLAST 4 ES8848 -46 SIGNA AMPS 13.64 V.A. 120 VOLTS WATTS 1,632 CIRCUITS 1 -20 AMP 60' -0" CABINET p2 0 4040 WA 8 G a 24275 �O 0NAL 51 3 90 65 ° EXPIRES: Gj1.54011 G 11 2010 1 B USE WHITE SILICONE TO NOTE: CONCEAL LIGHT LEAKS THIS SIGN IS INTENDED TO BE INSTALLED IN NOTE: ACCORDANCE WITH THE REQUIREMENTS OF SIGN INTERIOR TO BE PROVIDE A MINIMUM OF 30" ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE PAINTED GLOSS OF COILED WIRE TO ALLOW AND /OR OTHER APPLICABLE LOCAL CODES. ENAMEL WHITE FOR TOLERANCE:± 1/16" ON FOR BALLAST REMOVAL THIS INCLUDES PROPER GROUNDING AND BONDING MAXIMUM REFLECTIVITY ALL DIMENSIONS WHEN SERVICING. OF THE SIGN. EXISTING STEEL FRAME LOCATION: FEDERAL WA 1418 ELAQIURST RD. F LOCATION No.: 1805 icon ELK GROVE VILLAGE DRAVA= ME THE !• CLUSMEMIOPANTTOFICMIO EYSRMUMORI INC, AV REQUEST No.: 90802 ILLINOIS 60007 VUUTHOSIEED USE OR DUPLICATION It NOT EEEMFMIL THIS KINDS M INTENDED FOR IME n THE ICON COMPANIES ANDTHEIRWHOMVENO MMEUNICATION,AINERYAND DRAWN BY: CZESLAW RA _ IMDntlty Solutions IMTAUATIOL 1901 MAUS ISO CLAIM TO AMT PREMIUM, EEECMMA4 MECHUICLL M MUNUMN ENMMEIIIM IF THIS DEOU IC MO OUTSIDE OF THE ICON COMPANIES AND DATE DRAWN: 0141 0 2010 CICAI in. _ THFAMIIOKONFNODIIL nRAWIMC QCAI F• 1 = 1 10 EXISTING 2" X 2" STEEL ANGLE FRAME I RESUBMI 10' -5 1/2" CGP n 1 CITY OF FEDERAL WAY BUILDING DEPT. WELLS FARGO APPROVED BY: DATE: FII F• WELOdOOA ISHFFT- 1/3 C ID I EXISTING 2" X 2" STEEL ANGLE FRAME r - - -n -- n - -- -- n--------------- n-------------- - -----"-------- Tr �r �r - --Ir -� I II II II II II 1 II II II II II II I II 1 I II II II I II 1 II II II II II II I II I °�.� I II II II I II II II II II 11 1 II II 11 I II II II II II II I (V I II II I n II II II II 11 I 11 II n I II II II II I! I II II 2' —G II II 1'_3' I u . n II II li I II n n II II II II ______________ _lJ_______________u____________ II _V_ _____ II I II ______ V___ 1__ 1L______________ 1L_______ _______J1_______ II I II __ ________Y__J ELECTRIC INLET CABINET Mi CABINET (F2 (10 MOUNTING POINTS) (12 MOUNTING POINTS) 9' -6" 40' -0 1/2' EXISTING STEEL FRAME LOCATION: FEDERAL WA 1418 ELAQIURST RD. F LOCATION No.: 1805 icon ELK GROVE VILLAGE DRAVA= ME THE !• CLUSMEMIOPANTTOFICMIO EYSRMUMORI INC, AV REQUEST No.: 90802 ILLINOIS 60007 VUUTHOSIEED USE OR DUPLICATION It NOT EEEMFMIL THIS KINDS M INTENDED FOR IME n THE ICON COMPANIES ANDTHEIRWHOMVENO MMEUNICATION,AINERYAND DRAWN BY: CZESLAW RA _ IMDntlty Solutions IMTAUATIOL 1901 MAUS ISO CLAIM TO AMT PREMIUM, EEECMMA4 MECHUICLL M MUNUMN ENMMEIIIM IF THIS DEOU IC MO OUTSIDE OF THE ICON COMPANIES AND DATE DRAWN: 0141 0 2010 CICAI in. _ THFAMIIOKONFNODIIL nRAWIMC QCAI F• 1 = 1 10 EXISTING 2" X 2" STEEL ANGLE FRAME I RESUBMI 10' -5 1/2" CGP n 1 CITY OF FEDERAL WAY BUILDING DEPT. WELLS FARGO APPROVED BY: DATE: FII F• WELOdOOA ISHFFT- 1/3 C ID I y .iN P N 0 r N io b N -au N =Nv D N 0 � N I i+I 0 I -^ 2 5 /B' D FRAMING /LAMPING 'U' SCALE: 3/8 " =1' -0" -11 3/8' 1I1 11/16'. 4' -0' 1 4' -0' 1 4' -0' 1 4' -0' r 4' -0' 14 11/16; n FRAMING /LAMPING SCALE: 3/8' =1' -0" 1f � DETAIL SCALE. 1 1/2 " -1' -0" 3 _ ;' W. LEL ~�4O U IZ 1 N 70 }r W 24275 �O ,,�` EXPIRES: &1(51 01011 AUG 11 2010 4 BILL OF MATERIALS No. QTY. PART # DESCRIPTION SPECIFICATIONS 1 AS REQ'0 EXA478600 EXTRUSION, ALUMINUM #4786 BALLAST BOX 2 AS REO'D EXA477900 EXTRUSION, ALUMINUM #4779 2" LAMP BAR 3 AS REQ'D EXA504300 EXTRUSION, ALUMINUM 6 ", D/F 4 AS REQ'D - ALUMINUM CHANNEL .125" X 1" X 1/2" 5 AS REQ'D EXACS000 EXTRUSION, ALUMINUM CTS FRAME EXTRUSION 7 AS REO'D ALF375007 ALUMINUM FLAT STK BAR .375" X 1" X 16' -0" 8 AS REQ'D ALA188000 ALUMINUM ANGLE .188" X 1 1/2" X 1 1/2" X 25' -0" 9 AS REQ'O - ALUMINUM EXTRUSION FRAME SUPPORT JR. FSJR -P 10 AS REQ'D ALS050001W ALUMINUM SHEET PRECOAT .050" X 48" X 120" (WHITE) 11 AS REQ'D ALS090000 ALUMINUM SHEET .063" X 48 ". X 120 ". 3003 -1-114 22 AS REQ'D STA250002 STEEL ANGLE, PLAIN 1/4" X 2" X 2" X 20', A36 40 130 SQ.FT. VNL945001 3M PANAFLEX WHITE 3M PANAGRAPHICS 50 AS REQ'D - SHERWIN WILLIAMS PAINT, "MB" RED TO MATCH PMS 032, #V 51 AS REQ'O - SHERWIN WILLIAMS PAINT BLACK, SATIN FINISH 52 AS REO'D - VINYL, REGAL RED 3M, #3632 -85 53 AS REQ'D - VINYL. SUNFLOWER 3M. #3632 -25 54 AS REQ'D - VINYL, BLACK 3M, #3632 -22 55 AS REQ'O - PAINT, WHITE SPRAYLAT, GLOSS FINISH 60 15 LPF09600C FLUORESCENT LAMP F96T120CW /HO 61 3 LPF03600C FLUORESCENT LAMP F36T120CW /HO 62 4 - ELECTRONIC BALLAST (SIGNA) ESB848 -46 65 2 - SAFETY SWITCH w/ BOOT #SSB1 WESTRIM #38057, SINGLE POLE, 20 AMPS 68 1 - 1/2" ELECTRIC FITTING - 70 AS REQ'D I FSN000003 HEX BOLT 3/8 " -16 X 1 1/2 ", ZINC 71 AS REQ'D FSN 000010 HEX NUT 3/8 " -16. ZINC 73 AS REQ'D FSB000001 BOLT, HEX HEAD ZINC 1/4 " -20 X 1 1/2" 74 AS REQ'D FSN000005 NUT, HEX FINISHED 1/4 " -20, ZINC 76 AS REQ'D FSS000009 SCREW. HEX WASHER TEK #8 X 3/4 ", UNSLOTTED, ZINC 77 AS REQ'D FSS000008 SCREW, SM PHILLIPS #8 X 3/4" FLAT TYPE "AB" ZINC 80 AS REQ'D HNS050000 HINGE. STAINLESS STEEL .050" X 2" X 6' -0" 81 4 PROP LATCH 24" LONG, RUBBER TIP 82 AS REQ'O - CTS BAR, ALUMINUM 8" O.C. 83 AS REQ'D - CTS CLIP, STEEL 8" O.C. 89 AS REQ'D - DRAIN HOLE 5/16 "0, WITH SHADOW MESH, 4' -0" O.C., MAX. 90 - - UNION, U.L. AND ELECTRICAL LABEL_ LOCATION J� . 1418 ELMHURST RD. 1= 1COr1 ELK GROVE VILLAGE UNAUTHORIZED THE EXCLUSIVE ORUPLICATOPMIITNOT ICON IDENTITY TISDEMON IS INTENDED ILLINOIS 8000'7 UNAUTNORIEED USE OR DUPLICATION IS NOT PERMITTED. THIS OElHIM If INTENDED FOR USE " MY THE ICON COMPANIES AND THEIR APPROVED VENDORS IN FABRICATION, ASSEMBLY AND Identity Solution. INSTALLATION. ICON MANES NO CLAIM TO ANY STRUCTURAL, ELECTRICAL, MECHANICAL OR FOUNDATION ENGINEERING IF THIS DESIGN IS USED OUTSIDE OF THE ICON COMPANIES AND THE APPROVED VENDORS. LOCATION No.: 11805 REQUEST No.: 190802 DRAWN BY: ICZESL RESUBMITTED SEP 0 1 2010 CITY OF FEDERAL WAY BUILDING DEPT. WAY WA I WELLS RASZKA I APPROVED BY: DATE: A B C D V 4 r . 1 1 2 1 3 11 77 —' 3 - -' —' - - -- 76 —� 80 — I I I I I I n SECTION __ u C 4 iw -n s /A, B FACE FRAME DETAIL SCALE: 3/8 " =1' -0" 73 �v� 74 W. 401 WA H�G�� ~� 4Al �.A s-rE¢ G ssJaNAL �� EXPIRES: I S% 2.O 11 AUG 11 2010 SCALE: 3/8 "44" ITTED SEP 0 1 2010 CITY OF FEDERAL WAY BUILDING DEPT. 3' -0 5/16' 4' -0' 4' -0' 4' -0' 3' -0 5/16' - LOCATION: FEDERAL WAY, WA 1418 ELMRUR3R RD. � LOCATION No.: 1805 WELLS FA 4 ELK GROVE VILLAGE ��NEEME THE EXCLUSIVE MMERTYOF [CON ]IENRI7ECLIMONEINC.,MAY REQUEST No.: 90802 icon. MUNOIS 60007 UNAUFNORRED NNe DR DUPLICATION IN NOT PERMITTED. THIN @ANN n INT!NDED FoN ON NV THE ICON COMPAN IEN AND THEIR APPROVED VENDORS IN FABRICATION, ASSEMBLY AMP DRAWN BY: CZESLAW RASZKA APPROVED BY: DATE: Ra.ntlry aoRNEIO "' B FACE FRAME DETAIL SCALE: 3/8 " =1' -0" 73 �v� 74 W. 401 WA H�G�� ~� 4Al �.A s-rE¢ G ssJaNAL �� EXPIRES: I S% 2.O 11 AUG 11 2010 SCALE: 3/8 "44" ITTED SEP 0 1 2010 CITY OF FEDERAL WAY BUILDING DEPT. A C D N i "' - LOCATION: FEDERAL WAY, WA 1418 ELMRUR3R RD. � LOCATION No.: 1805 WELLS FA 4 ELK GROVE VILLAGE ��NEEME THE EXCLUSIVE MMERTYOF [CON ]IENRI7ECLIMONEINC.,MAY REQUEST No.: 90802 icon. MUNOIS 60007 UNAUFNORRED NNe DR DUPLICATION IN NOT PERMITTED. THIN @ANN n INT!NDED FoN ON NV THE ICON COMPAN IEN AND THEIR APPROVED VENDORS IN FABRICATION, ASSEMBLY AMP DRAWN BY: CZESLAW RASZKA APPROVED BY: DATE: Ra.ntlry aoRNEIO "' FOUNDATION a [CON MAKES THIS MUM ANY STRUCTURAL, OUTSIDEE OFF THE ICON CCMPAAMUNO DATE DRAWN: 07/30/2010 SIGN ID: - THE APPROVED 12M=& DRAWING SCALE: 1/4" = 1'-0" FILE: WEL0400A SHEET: A C D N i