Loading...
09-100807• Applicant Contractor �. Electrical City of Federal Way Community Development Services P.O. Box 9718 EVERGREEN STATE ELECTRIC INC 4 �. ", Permit #: 69-100807-00-EL Federal Way, WA 98063 -9718 Ph: (253) 835 -2607 Fax: (253) 835 -2609 ORTING WA 9831 +.:. Inspection Request P q Line: 253 835 -3050 ORTING WA 98360 Project Name: LEAL e O Project Address: 34701 5TH AVE SW 4 Parcel Number: 132172 0150 Project Description: Adding /altering (4) circuits for future porch and gazebo. Owner Applicant Contractor KARI LEAL EVERGREEN STATE ELECTRIC INC EVERGREEN STATE ELECTRIC INC co -owner Sandra Matteson @ 253- 952 -9343 PO BOX 1448 EVERGSE066JA (4/1/10) 34701 5TH AVE SW ORTING WA 9831 PO BOX.1448 FEDERAL WAY WA 98023 4 ORTING WA 98360 CAS � ' THIS CARD IS T(WMAIN ON -SITE CITY OF Community Development Inspection Record Federal Way IVR INSPECTION REQUEST PHONE # (253) 835 -3050 PERMIT #: 09- 100807 -00 -EL Owner: KART LEAL Address: 34701 5TH AVE SW FEDERAL WAY, WA 98023 -8357 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom).. Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. ❑ UFER Ground (4295) ❑ Ditch cover (4030) ❑ Slab /Concrete Floor (4255) Approved Approved Approved to place concrete By Date By Gti, Date By Date Pool Bonding (4195) ❑ Temporary Power (4275) ❑ Service (4235) Approved Approved Approved By Date By Date By Date ❑ Feeders /Sub - panels (4045) Approved By Date ❑ Final - Electrical (4055) Approved By Q, Date t 1,Oct ❑ Rough Electrical (4225) Approved By Date ❑ Ceiling Cover (4020) Approved By Date For inspector reference only ❑ Rough Electrical ❑ FINAL - Electrical Approved Approved By Date By Date ,m,. A.L Cae>PMENTasy Q 4.20►" PERMIT 33325 8 ER,eW WAY, 9 M PO -971 9 8 APPLICATION FEDERAL WAY, WA 98063-9718 22w 2 � FEDERAL WAY "q 0 E-07 SF MF CO M EL L DE EN FP The following is requirQ motion - an incomplete application will not be accepted. Please print legibly (in inV or type. PROPERTY O• SITE ADDRESS 34701 5th Ave SW, Federal Way WA SUrTE /UNIT# ASSESSOR'S TAx/PARCEL # -L 3L2-1 21 7? 41 0` _ - — — LOT SrzE (Sp LEGAL DESCRIPTION (e.g. Acme Estates, Lot i) Leal Residence (Annch -P...e P.Wf r ienyt W kQW descrWtloN E PROJECT INFORMATION TYPE OF PERMIT ❑ BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION IX ELECTRICAL ❑ ENGINEERING ❑ FIRE PREVENTION SYSTEM PROJECT DESCRIPTION (Provide detaiied description of work included on this aermft onlul Add /Alter 4 or fewer circuits for the followings install tow 20 Amp circuits, one for water feature & one for future porch / gazebo. Install new wire for postlights to replace wire damaged by other-; K add switch leg off of garage exterior lights for post lights. PROJECT NAME (Name of Business or Owner Last Namel Leal, K a r CONTRACTOR APPLICANT PROJECT CONTACT LENDER EBISTING USE PEOPLE INFORMATION NAME PRIMARY PHONE Leal, Kari ( 253) 347 -6330 MAIIING ADDRESS CITY, STATE. ZIP E -MAIL ADDRESS 147nl_ s COMPANY NAME APPLICANT NAME OFFICE PHONE Evergreen State El ( ) MAH ING ADDRESS CTIY. lIA . ZQ' CELL PHONE PO Box 849 ( ) CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER &PIRATION DAZE FAX NUMBER Sumner WA 98390 ( 253) 770 -1767 19-99-106639- FAX NUMBER t 2 5 B 770-1767 COPIRACTWS WW RA 010 NUMB= RxrntATM DATE E- MAILADDRESS EVERGSE066JA 04-01-2010 wizeclN.n�- vaihm.crm COMPANY NAME APPLICANT NAME OFFICE PHONE Evergreen State Electric (253)77 -0656 MMUNG ADDRESS UM, SfA1le, ZIP CELL PHONE PO Box 849 Sumner WA 98390 t ) - RELATiONSHIP TO PROJECT Architect ❑ Tenant ❑ Agent )g other E l e c t r i c a l Contract FAX NUMBER t 2 5 B 770-1767 NAME PRl14IARY PHONE E-MAIL ADDRESS (-Iris n:e ( 253 ) 770 -0656 veIre NAME Per RCW 19.27.095: yeller ir;formation is sequined Jfprelect value exceeds $5,000 - PROPOSED USE EBISTING ASSESSED /APPRAISED VALUE $ VALUE OF PROPOSED WORM $ SPPj NZLXRED BUILDING? ❑ YES ❑ NO FIRE SUPPRESSION SYSTEM PR0P0SED /RE9UM=? ❑ YES ❑ NO WATER SERVICE PROVIDER ❑ LAMEHAVEN o HIGHI M ❑ TACOMA ❑ PMATE (WELL) SEWER SERVICE PROVIDER ❑ LAMEHAVEN ❑ HIGIUME ❑ PRIVATE (SEPTIC) PEELECTRICAL PERMIT INFORMATION RESIDENTIAL COMMERCIAL NEW RESWENTM SERVICE NEW COMMERCIAL/INDUSTRIAL SERVICE • Single Family Square Feet Service or Feeder Each Add 'n (First 1300 ft2- $115.50; Each add'n 500 ft2 - $37.00) ❑ 0 to 100 amp $125.50 $ 76.50 • Detached outbuilding or garage ❑ 101 - 200 amp 155.50 98.00 (Inspected with service) $48.50 ❑ 201 - 400 amp 291.00 115.00 ❑ Detached outbuilding or garage ❑ 401 - 600 amp 339.50 136.00 (Inspected separately) $76.50 ❑ 601 - 800 amp 439.00 186.00 ❑ 801 - 1000 amp 536.50 224.50 NEW MULTI - FAMILY (three units or more) ❑ over 1000 amp 584-50 311.50 Service Feeder ❑ Up to 200 amp $125.50 $ 37.00 ❑ Over 600 volts surcharge $98.00 ❑ 201 - 400 amp 155.50 76.50 ❑ Mast or meter repair $106.00 ❑ 401 - 600 amp 212.50 106.00 �' COMMERCIAL/II�iDIISTRiAL ❑ 601 - 800 amp 272.00 145.50 ❑ Over 800 amp 389.50 291.00 Service or Feeders ❑ 0 to 200 amp $125.50 ALTERED SINGLE/MULTI FAMILY ❑ 201 - 600 amp 291.00 ❑ 601 - 1000 amp 439.00 Service or Feeder ❑ over 1000 amp 489.00 ❑ 0 to 200 amp $ 96.00 ❑ 201 - 600 amp 155.50 ❑ # of circuits to be added /altered ❑ over 600 amp 234.00 (1 -5 circuits - "8.00; Add'n circuits. $7.50 /ea) ®4 # of circuits to be added /altered COMMERCIAT. /INDIISTRIM PLAN REVIEW $98.00 plus 35% of permit Fee (1 -4 circuits- $76.50; AdWn circuits $7.50 /ea) ❑ 1,000 M FBe $W.00 Service - amps or greater ❑ Mast or meter repair $57.50 ❑ Med ical /Educational /Institutional Facility MANUFACTURED HOMES ❑ Service or feeder only $76.50 ❑ service and feeder $125.50 TEMPORARY SERVICE MOBILE SOME /RV PARS ResidertNal/Yuld- Family $67.50 ❑ # of service or feeders (First service/ feeder - $76.50; each addn 450.00) CornmerciaUbulustrial Servioe or Feeder Ampacity ❑ 0 - 100 amps $ 76.50 ❑ 101 - 200 amps 98.00 ❑ 201 - 400 amps 115.00 ❑ 401 - 600 amps 155.50 ❑ over 600 amps 168.00 MISCELLANEOUS SERVICEJEQUOYMENT ❑ # of Thermostats ❑ # of sips ( First - $57.50; add'n- $17.50 /ea) Wirst sign - $57.50; add'n sign $27.00 /ea) ❑ Low Voltage ❑ Swimming pool/hot tub ................ $115.00 Square Feet to be served by system(s) (Includes additional circuit. if requtred) ❑ Fire Alarm System ❑ Yard Pole meter loops ..................... $76.50 ❑ Security Alarm System ❑ Additional Plan Review $115.00 /hour ❑ Voice Cabling (for modified submittals) ❑ Data cabling 10 Automation Fee on all Permits .. $5.50 1a 2500 ft2 - $67.50; 2W9 1•e $6.00 Each add'n 2500 ft2 - $17.50) ' FL-r WAC 29646910150)6 8 iQ Bulletin #100 - January 1, 2008 Page 3 of 4 k\I-IandoutslPennit Application