Loading...
01-100870r S . � City a e way Community Development Services Building - Single Family Permit 01 - 100870 --01 SF 33530 1st Way S Federal Way, WA 98003 -6210 Ph: 233.661.4000 Fax: 253.661.4129 Inspection request line: 253.835.3050 Project Name: STONE Project Address: 1420 SW 296TH ST Parcel Number: 062104 9039 Project Description: ADD /ALT - Construct attached 3 -car garage and addition to main floor; remodel interior of lower and main floors of existing single family residence. Includes plumbing and mechanical work. * *Construct front entry and and garage man door decks. ** Owner Applicant Contractor Lender Christopher M Stone Christopher M & Margaret Stone CREATIVE REMODELING Christopher M & Margaret Stone 1425 SW 296TH ST 1425 SW 296TH ST CREATRI985C6 2/26/04 1425 SW 296TH ST FEDERAL WAY WA FEDERAL WAY WA 98023-3411 PO BOX 1013 FEDERAL WAY WA 98023-3411 98023 -3411 \ KENT WA 98035 -1013 \ Includes: Census category: 434 - Reside g rY� #1 #2 i U -1 #3 #4 Occupancy Group: R -3 Construction Type: Type V_N Type_V - N J — -- - - - - - -- —_ Occupancy Load: R£ Sinks — �r 1 � Floor Area (Sq, Ft.): ter Heaters 1st Floor Proposed Sq. Feet .............................. 350 Census Category... ....... .......... ............... 434 - Re Garage Proposed Sq. Feet . ........ ................758 Mechanical .................. ..... ........................... Yes Occupancy Group 42 ......................... .................. U -1 Total Building Sq. Feet ............. ...........................2214 4 Zoning Designation .............. ............................... R£ Basement Proposed Sq. Feet., .. .... ............10 lential altladd - no, Construction Type #2.......................................... Type V - P Height of Structure ............. .. ............19.5 Occupancy Group # 1 ............ ............................... R -3 Plumbing. .............. - .1 .................... ...... ... Yes Total Proposed Sq. Feet ........... ............................360 Plumbing Fixtures [— Description Quantit ( Descrption[Qtlantifi�r —�� 1, Description ___�,Quantlty B a htubs �1 Dishwashers Furnaces Laundry Washer Outlets i�l� Gas Logs rLavatories 4 Showers I� 2 Sinks — �r 1 Water Closets �� ter Heaters Mechanical Fixtures I_ Description Quanti FDescription (Quantity Description LQuantity j Fans Furnaces � Gas Logs Hoods i Ranges �F I I CONDITIONS: 1. No building shall encroach onto any building setback line /easement shown or not shown. 2. Building setbacks are: 20 feet front; 5 feet side; 5 feet rear. Additionally, any and all residential development activity on this parcel shall maintain a setback behind the stringline setback. 3. Maximum building height is 30 feet above the average building elevation. 4. Service connections for electrical and communication facilities shall be placed underground per Federal Way City Code (FWCC) section 16 -48. 5. Per FWCC section 22- 1133(4), eaves, chimneys or awnings, and similar elements of a structure that customarily extend beyond the exterior walls of a structure may extend up to 18 inches "MAXIMUM" into the required yard setback. 6. Prior to any clearing or grading on a lot, the owner /builder shall install temporary erosion/sedimentation control facilities approved by the City. These facilities must ensure that dirt or sediment laden water does not enter the public drainage system, adjacent lots or public streets. The owner /builder bears the responsibility to maintain the facilities in proper working order, replacing as necessary. The facilities may be removed only after such time as construction is r ~ j f .9mn, fete •k land caping is installed. S tached for standards and site plan for loc of silt fencing. e 7. he owner must obtain a Right -of- permit to install the new driveway, remove a old driveway, and install frontage improvements in SW 296th St. A 5 -foot paved shoulder is required per the modified right -of -way frontage improvements. The frontage improvements must be installed and approved by the Public Works inspector prior to occupancy. 8. The driveway shall be paved per FWCC section 22 -1453. The driveway shall be paved from the existing roadway pavement edge, or curb, to the garage. 9. This decision shall not waive compliance with future City of Federal Way codes, policies, or standards relating to the subject proposal. PERMIT EXPIRES August 17, 2004. Permit issued on February 19, 2004 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the u be ' accordan 'th the laws, rules and regulations of the State of Washington and the City of Federal Wa Owner or agent: Date: C9ty of Federal Way Community Development Services 33530 1st Way S Feder ;l Way, WA 98003 -6210 Ph: 253.661.4000 Fax: 253.661.4129 Building - Single Family Permit #: 01 - 100870 - 00 - SF Inspection request line: 253.835.3050 Project Name: STONE Project Address: 1420 SW 296TH ST Parcel Number: 062104 9039 Project Description: RES ADD /ALT - Construct attached 3 -car garage and addition to main floor; remodel interior of lower and main floors of existing single family residence. Includes plumbing and mechanical work. Owner Applicant Contractor Lender Christopher M & Margaret Stone Christopher M & Margaret Stone CREATIVE REMODELING Christopher M & Margaret Stone 1425 SW 296TH ST 1425 SW 296TH ST CREATR *0130L 9/11/02 1425 SW 296TH ST FEDERAL WAY WA 98023-3411 FEDERAL WAY WA 98023 -3411 PO BOX 1013 FEDERAL WAY WA 98023-3411 Occupancy Group # 2 ................... ............................0 -1 KENT WA 98035 -1013 Yes Includes: Census category: 434 - Reside #1 #2 #3 44 Occupancy Group: R -3 U -1 Garage Proposed Sq. Feet ............ ............................758 Bathtubs I Construction Type: Type V - N Type V - N Yes Occupancy Group # 1 ............................................... Occupancy Load: Occupancy Group # 2 ................... ............................0 -1 Plumbing.................. ............................... Yes Floor Area (Sq. Ft.): Total Proposed Sq. Feet ........................................... 360 Zoning Designation .................. ............................... 1st Floor Proposed Sq. Feet ......... ............................350 1 Basement Proposed Sq. Feet .................................... 10 Census Category .................. ............................... 434 - Residential alt/add - no cl Construction Type # 2............... ............................... Type V - N Garage Proposed Sq. Feet ............ ............................758 Bathtubs I Height of Structure.................. ............................... 19.5 Mechanical .................. ............................... Yes Occupancy Group # 1 ............................................... R -3 Occupancy Group # 2 ................... ............................0 -1 Plumbing.................. ............................... Yes Total Building Sq. Feet ................. ...........................2214 Total Proposed Sq. Feet ........................................... 360 Zoning Designation .................. ............................... RS 15.0 Plumbing Fixtures :.::: :::::;:::«<: >:.:.:::..::....:.: 1 >::.:::;:.:::;:.:.::.:::.::::::.tk...n..................... �a. ah��:.:><>»>><€ �e� ..r.�....0n.................... Quin...... Dishwashers 1 Laundry Washer Outlets 1 Bathtubs I Lavatories 4 Water Heaters 1 Showers Sinks 1 Water Closets 3 Mechanical Fixtures Furnaces 1 Fans ll 4 �cr. GE[anttt': tEan..................... P... .......... .....:....:..:...............:. . Gas Logs Ranges 1 Hoods 1 CONDITIONS:, 1. No building shall encroach onto any building setback line /easement shown or not shown. 2. Building setbacks are: 20 feet front; 5 feet side; 5 feet rear. Additionally, any and all residential development activity on this parcel shall maintain a setback behind the stringline setback. 3. Maximum building height is 30 feet above the average building elevation. 4. Service connections for electrical and communication facilities shall be placed underground per Federal Way City Code (FWCC) section 16 -48. 5. Per FWCC section 22- 1133(4), eaves, chimneys or awnings, and similar elements of a structure that customarily extend beyond the exterior walls of a structure may extend up to 18 inches "MAXIMUM" into the required yard setback. 6. Prior to any clearing or grading on a lot, the owner /builder shall install temporary erosion /sedimentation control facilities approved by the City. These facilities must ensure that dirt or sediment laden water does not w enter the public `drainage system, adjt lots or public streets. The owner /builder�rs the responsibility to maintain the facilities in proper working order, replacing as necessary. The facilities may be removed only after such time as construction is complete & landscaping is installed. See attached for standards and site plan for location of silt fencing. 7. The owner must obtain a Right -of -Way permit to install the new driveway, remove the old driveway, and install frontage improvements in SW 296th St. A 5 -foot paved shoulder is required per the modified right -of -way frontage improvements. The frontage improvements must be installed and approved by the Public Works inspector prior to occupancy. 8. The driveway shall be paved per FWCC section 22 -1453. The driveway shall be paved from the existing roadway pavement edge, or curb, to the garage. 9. This decision shall not waive compliance with future City of Federal Way codes, policies, or standards relating to the subject proposal. PERMIT EXPIRES August 31, 2002, IF NO WORK IS STARTED. Permit issued on March 4, 2002 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use w' 1 be in ccord ce wit laws, rules and regulations of the State of Washington and the City of Federal W Owner or agent: Date: U7 � % INSPECTION LOG a I./ AV L1 a I./ AV FEIZFIL `,vim crY, POST THIS CARD ON THE FRONT OF BUILAING BU DIVISION INSPECTION RECORD INSPECTION REQUEST PHONE #: 253- 835 -3050 PERMIT #: 61- 100870 -00 -SF OWNER'S NAME: Christopher M & Margaret Stone SITE ADDRESS: 1420 SW 296TH 5T ( ) FOOTINGS /SETBACKS /D - 7!Z - V !Z - ( ) FOUNDATION WALL () DRAINAGE: Line () Connection ' �. #.a UTPOL7RLrBa I,LTHE ABOVE IS APP„RO D _ . _...._ . OPW () UNDERFLOOR FRAMING O ROUGH PLUMBING: DWV d Water piping O ROUGH MECHANICAL V/ by Gas piping () SHEATHING Roof 173 Floor () SHEAR WALLS O ELECTRICAL ROUGH -IN I y Ditch Cover 0/_Ov r-C S () FIRE/DRAFTSTOPS ( ) FRAMING/FIRESTOPPING 4/ CfT10f c-- ry CONSTRUC17tJN PERMIT APPLICATION VV FiY� �'� PPLICATION NUMBER: - D _(,' ('_ -SF PPLICATION NUMBER: - - B 1LDIivG DEPT. APPLICATION NUMBER: - - * *The following is required information — Please print (in ink) or type ** Please note: Electrical, Fire Prevention Systems and Engineering permits may require a separate application— PROPERTY INFORMATION SITE ADDRESS: h\\l (% j . ASSESSOR'S TAX/ PARCEL #: O (0 04.4,- t� �.L1a1l 7� LEGAL DESCRIPTION OF SUBJECT PROPERTY (ATTACH SEPARATE DESCRIPTION IF LENGTHY): Cj � C22lm ' ■ PROJECT INFORMATION TYPE OF PROJECT (This application): A BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ELECTRICAL ❑ ENGINEERING❑ FIRE PREVENTION SYSTEM PROJECT DESCRIPTION (Provide detailed description): jQEi'j0j2W_ Eitl� ?V /4 V PROJECT NAME: A a ■ PEOPLE INFORMATION PROPERTY OWNER: CONTRACT D APPLICANT: CONTACT PERSON UAY I1Mt PHUNU RS3) S CITY, STAVE, ZIP)* ' Iq g it r 3T NAME: DAYTIME PHONE: r @q�� t3C l'C'rw�E pG :wy - (ZOG ) �/8 - z33s' MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP): EVENING PHONE: I BOY /U i3 Ce,4 Gv,ot 9f O3S' (Zs'-3 ) 939 - 13s -0 CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: FAX NUMBER: 83 57 CONTRACTOR'S REGISTRATION NUMBER: EXPIRATION DATE: I (copy of card required) C r" e A T % O t 3 0 O 9 // l / ?Co Z j NA�� 4 � DAYTIME PHONE: 0 - 'e 7 MAILING ADDRESSSO DDRESS; CITY, STATE I : EVEENINGPHONE: �� Q-53-)W RELATIO HIP TO PROJECT: ❑ ARCHITECT ❑ TENANT ❑ OTHER( DESCRIBE): FAX NUMBER: , ) �3 c - j3 1 =0R THIS PROJECT: PROPERTY OWNER ❑ APPLICANT ❑ CONTRACTOR E -MAIL ADDRESS: f1F.3 0T Q �Q@ i EXISTING USE: EXISTING BUILDIN ASSESSEd %APPRAISED VALUATION $ /! PROPOSED USE: >�wv1 PROPOSED VALUATION FOR IMPROVEMENTS: $ )z/ C- SPRINKLERED BUILDING? ❑ YES XNO FIRE SUPPRESSION SYSTEM PROPOSED/ REQUIRED: ❑ YES XNO WATER SERVICE PROVIDER: ALAKEHAVEN ❑ HIGHLINE ❑ TACOMA ❑ PRIVATE (WELL) SEWER SERVICE PROVIDER: x LAKEHAVEN ❑ HIGHLINE ❑ PRIVATE (SEPTIC) �nQ-i Cam L] * *NEW RESIDENTIAL CONSTRUCTION ONLY ** NUMBER OF BEDROOMS: • ESTIMATED SELLING PRICE: ■ PR03ECT FLOOR AREAS FLOOR EXISTING S . FT. PROPOSED S . FT. TOTAL BASEMENT COMP PLAN DESIGNATION BASIC PLAN? ❑ YES ❑ NO SECTION TOWNSHIP RANGE FIRST PLATTED LOT? ❑ YES ❑ NO I CHANGE OF USE? ❑ YES ❑ NO SECOND THIRD FOURTH OTHER FLOORS (DESCRIBE) DECK GARAGE HOW MANY FLOORS? TOTAL: AIR HANDLING UNIT(S) BBQ(S) BOILER(S) COMPRESSOR(S) DUCT(S) BATHTUB(S) k DISHWASHER(S) DRINKING FOUNTAIN(S) GAS PIPE OUTLET(S) INTERCEPTORS) Indicate number of each type of fixture MECHANICAL EVAPORATIVE COOLER(S) 2 GAS LOG(S) REFRIG. SYSTEM(S) _ FAN(S) �— HOOD(S) WOODSTOVE(S) FIREPLACE INSERTS) RANGE(S) MISC. ( ) i FURNACE(S) GAS PIPE OUTLET(S) HEAT SOURCE: ❑ ELECTRIC ❑ GAS PLUMBING �I LAVATORY(S) RAIN WATER SYS. SHOWER(S) T SINK(S) SUMP(S) URINALS) VACUUM BREAKER(S) I_ WASH MACHINE OUTLET S— WATER CLOSET(S) MCILATMFRISTGNATURE BLC WATER HEFER(S) ❑ ELECTRIC L`7 GAS MISC. ( ) I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and further, that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the City of Federal Way, but o w e such c im ar" es out of the reliance of the city, including its officers and employees, upon the accuracy of the informatio sup to he ty as art of thi lication. C� NAME /TITLE: P DATE: ✓ f " " / XPROPERTY OWNER ❑ APPLICANT ❑ CONTRACTOR FOR OFFICE USE ONLY: ❑ NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ TENANT IMPROVEMENT CENSUS CODE: LOT SIZE: ZONING DESIGNATION: BUILDING SHELL ONLY? ❑ YES ❑ NO COMP PLAN DESIGNATION BASIC PLAN? ❑ YES ❑ NO SECTION TOWNSHIP RANGE NEW ADDRESS REQUIRED? ❑ YES ❑ NO PLATTED LOT? ❑ YES ❑ NO I CHANGE OF USE? ❑ YES ❑ NO COMMUNITY DEVELOPMENT SERVICES • 33530 FIRST WAY SOUTH • P.O. BOX 9718 • FEDERAL WAY, WA 98063 -9718 • 253- 661 -4000 • FAX: 253- 661 -4129 • Construction Permit Fee Calculation Sheet * * * * ** *PLEASE NOTE: ALL FEES MUST BE VERIFIED BY CITY STAFF PRIOR TO ACCEPTANCE OF PAYMENT. CHECKS FOR INCORRECT AMOUNTS WILL NOT BE ACCEPTED! * * * * * ** Building, mechanical, and fire prevention system fees are based on the following schedule. TABLE A TOTAL VALUATION FEE FACTOR (1) $1.00 to $500.00 (1) $24.25 (2) $501.00 to $2,000.00 (2) $24.25 for the first $500.00 plus $3 27 for each additional $100.00or fraction thereof, to and including $2,000.00 (3) $2,001.00 to $25,000.00 (3) $71.46 for the first $2,000.00 plus $15.00 for each additional $1,000.00 or fraction thereof, to and including $25,000.00 (4) $25,001.00 to $50,000.00 (4) $403.61 for the first $25,000.00 plus $1x82 for each additional $1,000.00 or fraction thereof, to and including $50,000.00. (5) $50,001.00 to $100,000.00 (5) $664.35 for the first $50,000,00 plus $750 for each additional $1,000.00 or fraction thereof, to and including $100,000.00. (6) $100,001.00 to $500,000.00 (6) $1,025.55 for the first $100,000.00 plus $6.00 foreach additional $1,000.00or fraction thereof, to and including $500,000.00 (7) $500,001.00 to $1,000,000.00 (7) $3,337.23 for the fist $500,000.00 plus $509 for each additional $1.000.00or fraction thereof, to and including $1,000,000.00. (8) $1,000,001.00 and up (8) $5,788.23 for the first $1,000,000.00 plus $3.91 for each additional $1.000.00 or fraction thereof. Bold number is the base fee for the specified increment Italicized underlined number is the fee per additional speciTed increment PLUS: Add 65 percent of the base building permit tee for plan review Tee. Add 25 percent of the base mechanical permit fee for mechanical plan review fee. Add 15 percent of the base building permit fee for Fire District #39 surcharge, commercial only. Add $4.50 for WA State Building Code Council, plus $2.00 per unit for duplex & above. ** Electrical, plumbing, and mechanical fees are calculated separately ** PROPOSED VALUATION: FEE FACTOR FROM TABLE A: Number: Estimated Permit Fee: (1 Estimated Plan Review Fee: (2) Estimated FW Fire Department Surcharge: (3) (COMMERCIAL ONLY) PROPOSED VALUATION: FEE FACTOR FROM TABLE A: Number: Estimated Permit Fee: ( Estimated Plan Review Fee: Q (a) Base Fee: (b) Additional Increment Fee: (a) Base Fee: (b) Additional Increment Fee: ■ FIRE PREVENTION SYSTEM PROPOSED VALUATION: FEE FACTOR FROM TABLE A: Number: (a) Base Fee: (b) Additional Increment Fee: Estimated Permit Fee: (6) Estimated Plan Review Fee: (7) Base Fee Number of Fixtures $21.00+( X $7.00 /fixture) _ (8) Estimated Permit Fee Estimated Permit Fee X .65 = (9) Estimated Plan Review Fee Miscellaneous Fixture Charge: (10) Sub Total (Page one): Line(s) ( 1)+( 2)+( 3) +(4) +(5) +(6) +(7) +(8) +(9) +(10) = (11) City of Federal Way - I ildin Single Family Permit #: 01- 100870 - 00 - SF e t Community Development Services Christopher M & Margaret Stone g g CREATIVE REMODELING 33530 1st Way S 1425 SW 296TH ST 1425 SW 296TH ST CREATR *0130L 9/11/02 Feclend Way, W.4 98003 -6210 FEDERAL WAY WA 98023 -3411 FEDERAL WAY WA 98023 -3411 Inspection request line: 253.835.3050 Ph 253 661 4000 Faxi 253.661 .4129 Showers Total Proposed Sq. Feet ............................ KENT WA 98035 -1013 1 Project Name: STONE Project Address: 1420 SW 296TH ST Parcel Number: 062104 9039 Project Description: RES ADD /ALT - Construct attached 3 -car garage and addition to main floor; remodel interior of lower and main floors of existing single family residence. Includes plumbing and mechanical work. Owner Applicant Contractor Lender Christopher M & Margaret Stone Christopher M & Margaret Stone CREATIVE REMODELING Christopher M & Margaret Stone 1425 SW 296TH ST 1425 SW 296TH ST CREATR *0130L 9/11/02 1425 SW 296TH ST FEDERAL WAY WA 98023 -3411 FEDERAL WAY WA 98023 -3411 PO BOX 1013 FEDERAL WAY WA 98023 -3411 Showers Total Proposed Sq. Feet ............................ KENT WA 98035 -1013 1 Includes: Census category: 434 - Reside #1 42 #3 94 Occupancy Group: R -3 U -1 Height of Structure.... ............................... Mechanical .................. ............................... Construction Type: Type V - N Type V - N -1 Plumbing.................. ............................... Occupancy Load: Showers Total Proposed Sq. Feet ............................ Sinks 1 Floor Area (Sq. Ft.): 3 1 st Floor Proposed Sq. Feet ......... ............................350 w�t�t►� Basement Proposed Sq. Feet..................... Census Category .................. ............................... 434 - Residential alt/add - no cl Construction Type # 2 ............................... Garage Proposed Sq. Feet ............ ............................758 1 Height of Structure.... ............................... Mechanical .................. ............................... Yes Occupancy Group # 1. .............................., OccupancyGroup 92 ................... ............................0 -1 Plumbing.................. ............................... Total Building Sq. Feet ................. ...........................2214 Showers Total Proposed Sq. Feet ............................ Zoning Designation .................. ............................... RS 15.0 Plumbing Fixtures ......10 ...... Type V - N ..... 19.5 ...R -3 Yes 360 <G?escr� ±o�,,:.;;» . , . w�t�t►� ;:. >;::: I3e�Gn:RI�R ;:., ..ua�ttt Ae��ripti�n �iantlty Dishwashers 1 Laundry Washer Outlets 1 Bathtubs 1 Lavatories 4 Water Heaters 1 Showers 2 Sinks 1 Water Closets 3 Mechanical Fixtures CONDITIONS: 1. No building shall encroach onto any building setback line /easement shown or not shown. 2. Building setbacks are: 20 feet front; 5 feet side; 5 feet rear. Additionally, any and all residential development activity on this parcel shall maintain a setback behind the stringline setback. 3. Maximum building height is 30 feet above the average building elevation. 4. Service connections for electrical and communication facilities shall be placed underground per Federal Way City Code (FWCC) section 16 -48. 5. Per FWCC section 22- 1133(4), eaves, chimneys or awnings, and similar elements of a structure that customarily extend beyond the exterior walls of a structure may extend up to 18 inches "MAXIMUM" into the required yard setback. 6. Prior to any clearing or grading on a lot, the owner /builder shall install temporary erosion /sedimentation control facilities approved by the City. These facilities must ensure that dirt or sediment laden water does not ;,�esori :aEarr . �.t�tlttt:': Furnaces 1 Fans 4 Gas Logs 2 Ranges I Hoods I CONDITIONS: 1. No building shall encroach onto any building setback line /easement shown or not shown. 2. Building setbacks are: 20 feet front; 5 feet side; 5 feet rear. Additionally, any and all residential development activity on this parcel shall maintain a setback behind the stringline setback. 3. Maximum building height is 30 feet above the average building elevation. 4. Service connections for electrical and communication facilities shall be placed underground per Federal Way City Code (FWCC) section 16 -48. 5. Per FWCC section 22- 1133(4), eaves, chimneys or awnings, and similar elements of a structure that customarily extend beyond the exterior walls of a structure may extend up to 18 inches "MAXIMUM" into the required yard setback. 6. Prior to any clearing or grading on a lot, the owner /builder shall install temporary erosion /sedimentation control facilities approved by the City. These facilities must ensure that dirt or sediment laden water does not enter the public drainage system, atent lots or public streets. The owner /buildle-ars the responsibility to maintain the facilities in proper working order, replacing as necessary. The facilities may be removed only after such time as construction is complete & landscaping is installed. See attached for standards and site plan for location of silt fencing. 7. The owner must obtain a Right -of -Way permit to install the new driveway, remove the old driveway, and install frontage improvements in SW 296th St. A 5 -foot paved shoulder is required per the modified right -of -way frontage improvements. The frontage improvements must be installed and approved by the Public Works inspector prior to occupancy. 8. The driveway shall be paved per FWCC section 22 -1453. The driveway shall be paved from the existing roadway pavement edge, or curb, to the garage. 9. This decision shall not waive compliance with future City of Federal Way codes, policies, or standards relating to the subject proposal. PERMIT EXPIRES August 31, 2002, IF NO WORK IS STARTED. Permit issued on March 4, 2002 I hereby certify that the above information is correct a d that the construction on the above described property and the occupancy and the u be in ac rdan e wi e laws, rules and regulations of the State of Washington and the City of Federal W ,'-- Owner or agent: Date: �9 m v u �p,j lip� 5 7 120 PROVIDE SILT FENCE A5ANG CLEARING LIMITS LINE A MAINTAIN DURING CONST. I I3 I vI O I $I EL +110.0' _ I110 y ?EEp yL ' O NG• �GO GRADING OGLE I' I r� E ELED RE EL. 2 138. mMIRA, all TION OF E-R� I 16-71/0- 32'-0 3/4' Al= EXIST." _� = —6t EXISTING Y RESIDENCE �p I REMOVE I EXISTIN6 50m 41 / RE AININ& REGRADE AREA I `� I GONG. WALL I FOR GENTLE SLOPE TO WEST PROP. I LINE — I C14� I 140 I I I I 60.74' EL. 141.0 5D I —1 5' -O" STREET _ . 5 I TE' 50A.LE: 50A I "= 1:' -O" 21 EL. 142.0' 120 O cim EXI5TING RESIDENCE 4' -O" MAX. ROCKERY ROCKERY I CJ 0 LOT COVERAGE CALCULATIONS: EXISTING TOTAL SITE AREA: 21,600 S.F. +l- STRUCTURE / OVERHANGS 13410 S.F. DRIVES / WALKS Igg3 S.F. / DECKS: (FUTURE AND PROPOSED) 0 S.F. TOTAL IMPERVIOUS COVERAGE: S.F. (15.61%) 3383 NEW IMPERVIOUS COVERAGE: CALCULATED FILL I410 cu yds 140 LEGAL DESCRIPTION: STIR 062104 TAXLOT 31 E 60 FT OF W 400.11 FT OF GL 4 LE55 5 40 FT FOR ROAD BEGINNING AT A POINT N 00 °08'43" W 40 FEET AND N Moll'' 340.11 FEET FROM THE SOUTHWEST CORNER OF GOVERNMENT SECTION 6, TOWNSHIP 21 NORTH, RANGE 4 EAST, W.M., IN KING WASHINGTON; THENCE CONTINUING N M*1154" 60 FEET, MORE OR LESS, TO GOVERNMENT MEANDER LINE; THENCE 5OUTHWE5TERLY, ALONG SAID MEANDER LINE, TO A F N 00 °0246" E OF THE POINT OF BEGINNING; THENCE 5 00 002'46' W 5M.g1 FEET, MORE OR LESS, TO THE BEGINNING. (ALSO KNOWN AS LOT 15, BLOCK 1, MILWAUKEE TERRACE, ACC TO THE UNRECORDED PLAT THEREOF) 51TUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. NOTE: ALL DOWN5POUT5, ROOF AND FOOTING DRAINS SHALL BE TIGHTLINED TO AN APPROVED STORM DRAINAGE SYSTEM UNLE55 OTHERWISE APPROVED NOTE: CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES PRIOR TO BEGINNING CONST. NOTE; E NO DIRT, MUD, ROCK, SOIL, OR DEBRIS WILL BE TRACKED FROM THE 51TE TO THE STREET I