Loading...
09-100293v 9 City of Federal Way Community Development Services P.O. Box 9718 Federal Way, WA 98063 -9718 Ph: (253) 835 -2607 Fax: (253) 835 -2609 Project Name: BANK OF AMERICA Project Address: 32001 32ND AVE Suite 110 `LL -Sign Permit #: 09- 100293 -00 -SG :,►�� Inspection Request Line: (253) 835 -3050 Parcel Number: 215465 0010 Project Description: Replace existing channel letter signage with new cabinet sign. Electrical attachment to be included on existing Xbox. ne Applican Contractor BANK OF AMERICA MORTGAGE VANCOUVER SIGN VANCOUVER SIGN 33438 1ST WY S 6615 NE HWY 99 VANCOSC147CQ (10/30/09) FEDERAL WAY WA 98063 VANCOUVER WA 98665 6615 NE HWY 99 VANCOUVER WA 98665 �F t'cmivii I cAi iKCJ IYlonuay, August -IV, AUVV Permit Issued on Wednesday, February 11, 2009 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and 84-11 of Federal,�IVay. Owner or agent: iiijpilcation Date: FEB 112009 -� L"Lz - THIS CARD IS TWMAIN ON -SITE CITY OF Community Development Inspection Record Federal Way IVR INSPECTION REQUEST PHONE # (253) 835 -3050 PERMIT #: 09- 100293 -00 -SG Owner: BANK OF AMERICA MORTGAGE Address: 32001 32ND AVE Suite 110 FEDERAL WAY, WA 98001 -9625 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD, Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. ❑ Footings /Setback (4110) ❑ Final - Electrical (4055) ❑ Final - Sign (4085) Approved to place concrete Approved Approved By Date By '' Date b By Date 6 , ❑ Attachment (4010) Approved By Date to , 3_C,g For inspector reference O Rough Electrical Approved By Date O FINAL - Electrical Approved By Date I S t CITY OF SIGN PERMIT Federal Way JAN 21 "APPLICATION o �P- / 00-2g3_ 00 ro 2 IZ O 7 1 SITE ADDRESS J G. VU 1 J G AN) e 110 Ir -5 SUITE /UNIT # ASSESSOR'S TAX /PARCEL # Z I S t{ Co S - O I O ZONING DESIGNATION G TYPE OF PROJECT (Check all that apply): K PERMANENT ❑ TEMPORARY ❑ NEW ❑ ALTERATION ❑ REFACE ❑ EXEMPT )< ELECTRICAL (To attach to existing J -box - include on this permit) ❑ ELECTRICAL (New /altered circuit & J -box added - separate permit is required) NUMBER OF SIGNS APPLIED FOR WITH THIS APPLICATION: Wall Mounted: 1 Freestanding: O TOTAL ESTIMATED PROJECT COST: $ 3)0(-) DETA LED PROJECT DESCRIPTION: BUSINESS NAME ON SIGN: SIGN OWNER: CON CTOR: b COPY of card with erch APPLICANT PROJECT CONTACT o -V /+yK ears NAME: Punk o� Ayrex►ca` PRIMARY PHONE ( ) MAILING ADDRESS (STREET ADDRESS: CITY, STATE, ZIP): 32-001 3 3 N ° A9 6r, #110, 315 Feo(,e,ca. " trJ Pc FAX NUMBER ( ) - CITY IOF F B NE(A—' -n NUMBER L:-- (Required en permit is cx E-MAIL ADDRESS COMPANY NAME Vancouver Sign APPLICANT NAME OFFICE PHONE (360)693 - 4773 MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP): CELL PHONE 6615 NE HWY 99 Vancouver WA 98665 ( ) - CITY OF FEDERAT. UTev n..o.- --�-- - �- - -- - q IRAnON ATE: FAX NUMBER (360 )693 - 2747 CON6XCTOR'S REGISTRATION NUMBER: FXPIItATi N DATE: Vancouver WA 98665 E -MAIL ADDRESS VANCOS *258BC y ( Q E -MAIL ADDRESS COMPANY NAME APPLICANT NAME PRIMARY PHONE - Vancouver Sign (360)693 - 4773 - MAILING ADDRESS CITY. STATE, ZIP FAX NUMBER 6615 NE HWY 99 Vancouver WA 98665 (360)693 - 2747 RELATIONSHIP TO PROJECT E -MAIL ADDRESS -V Contractor ❑ Tenant ❑ Other NAME PRIMARY PHONE E -MAIL ADDRESS: Reid. Storm (340 ) 613 - cd:js@ 0(,LNS'15n.co, cory I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and further, that I am authorized by the owner of the above premises to perform the work for which the permit application is made SIGNATURE DATE: _ zz 0 & l COMMUNITY DEVELOPMENT SERVICES • 33325 8TH AVENUE SOUTH • PO BOX 9718 • FEDERAL WAY, WA 98063 -9718 • 253 - 835 -2607 • FAX: 253 - 835 -2609 TYPE /PURPOSE OF EVENT: DATE OF INSTALLATION: DATE OF REMOVAL: TOTAL CALENDAR DAYS: DESCRIPTION OF PROPOSED SIGNAGE : PERMANENT FREE STANDING: MONUMENT PEDESTAL POLE TENANT DIRECTORY OTHER OTHER (Describe) PERMANENT BUILDING MOUNTED: AWNING . >( CABINET CHANNEL LETTERS TENANT DIRECTORY OTHER (Describe) FREE STANDING SIGNS MOUNTED SIGNS SIGN TYPE SIGN AREA (SQ. FT.) ILLUMINATED? REFACE? TOTAL HEIGHT BASE HEIGHT (FT) �I WIDTH x HEIGHT x # OF FACES NO /INT /EXT YES NO . FT. A A Ai NUMBER OF SIGNS ALLOWED: J y�00 LAND USE APPROVAL BY: DATE: ( STRUCTURAL APPROVAL BY: G DATE: .. Q REGISTRATION NUMBER: 00 10 REGISTRATION NUMBER: x x — REGISTRATION NUMBER: B REGISTRATION NUMBER: B x x — x x — C x x — D X x — STREET FRONTAGE (LINEAR FEET): x x — BUILDING MOUNTED SIGNS BUILDING MOUNTED SIGNS SIGN TYPE SIGN AREA (SQ. FT.) ILLUMINATED? BUILDING ELEVATION EXPOSED BUILDING FACE �I WIDTH x HEIGHT x # OF FACES NO INT EXT N S E W . FT. A STREET FRONTAGE: Ai NUMBER OF SIGNS ALLOWED: J y�00 LAND USE APPROVAL BY: DATE: ( STRUCTURAL APPROVAL BY: G DATE: .. Q REGISTRATION NUMBER: 00 10 REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: B REGISTRATION NUMBER: x x — C x x — D x x — E x x — LARGEST EXPOSED BUILDING FACE (SQUARE FEET): 9 % O O * *FOR OFFICE USE ONLY** ZONING DESIGNATION: Of, j PROFILE: ❑ HIGH ❑ MEDIUM ❑ LOW ❑ FREEWAY BUILDING MOUNTED SIGNS FREE STANDING SIGN (S) Z AREA PERMITTED: AREA PERMITTED: �I AREA PROPOSED: 50 / AREA PROPOSED: A-1 OO LARGEST BUILDING FACADE: STREET FRONTAGE: NUMBER OF SIGNS ALLOWED: J NUMBER OF SIGNS ALLOWED: LAND USE APPROVAL BY: DATE: ( STRUCTURAL APPROVAL BY: G DATE: .. Q REGISTRATION NUMBER: 00 10 REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: 0 F3ank Of America - countrywide #nChart Exterior Existing Signage Sign #: 001 Exterior Sign Type: Channel Letters Face Material: Flat Plastic Graphics Material: Vinyl Overall Height: 360" Face Height: 24" Face Width: 303" Square Feet: 50.5 illuminated: Internally Illuminated Electrical: Electrical Power within 8' Wall Material: Proposed Signage Action Code: Remove and Replace New Sign Type: HL -135r Description: 17' -11 1/8" x 2' -9 3/4" Horizontal Red Wall Cabinet Required Site Work Restoration & Fabrication Notes: Patch and repair existing wall surface to like new condition. Repaint to match existing color finish. For brick or stone walls fill holes with matching silicone. Install new signage using existing primary electrical. Verify if additional circuits are required for new sign. Field verify dimensions of the sign & surrounding space shown in the proposed image. If the field verification indicates that the sign will not fit, or may appear substantially different than the proportions shown in the proposed image, an IFR should be submitted for modification by Monigle Associates prior to any manufacturing. Comments: Page 5 of 16 a.Y- : 50-so � 115r Propo '.e l . 6 4 17 -11 '/$1, x Zr, 9 3/411 5A A Z SAP = So 6.paae For Legal Disclaimer Monigle https:// countrywide. signchart.con /prinUprintbook_view.asp t`1 • CITY OF FEDERAL WAY DEPT: OF COA0,0lUNrry n17vF! r MENT F PERMIT: #09- 100293 -00 SGt A ADDRESS. 32001 32ND AVENUES PROJECT: CABINET SIGN F OWNER: BANK OF AMERICA G DATE: 1/22/09 ' 1�9�I��U� "RTE➢ �c�� r_ ,rc —� APPRO! -� 1/20/2009 RECEIVED JAN 2 2 2009 OF FEDERAL WAY GDS !� 0 0 Ill-111/81 TOP VIEW 111-111/81 SCALE: t/2' -I' -0' L m 2 HL —D5r — 2' -S 3/4' WALL SIGN s 50 SQFT. SCALE: I!1' -1' -0' ;�i;Q TOP VIEW v 14' -4 1/8' 14' -4 1/8' R- 154' -4 3/4' SCALE: 1/1' - I' -0' 3/4' F� ankofAmeri�a %� H� - Im. � ome n s a ° ■ �`` n o a'�h Home l• oa [TOO ns O ■.a ma Mai L m 2 HL —D5r — 2' -S 3/4' WALL SIGN s 50 SQFT. SCALE: I!1' -1' -0' ;�i;Q TOP VIEW v 14' -4 1/8' 14' -4 1/8' R- 154' -4 3/4' SCALE: 1/1' - I' -0' 3/4' v A NHL —D4r — 2' -3' WALL SIGN a 32 SOTT- SCALE: 1/Y•1' -0' These documents are for design intent and shall be used only as a guide to produce the finished sizes, appearances and functions shovrn. Nothing contained In these documents shall be construed as a design for any engineered element. The fabricator /contractor shall be responsible for all, structural, electrical, mechanical and foundation engineering. See General Specifications for additional requirements. These documents were not produced under an architectural services agreement These drawings a blished design by Monigle Associates, Inc. The detailing and information contained on these pages shall rot be reproduced, copied or utilized except for the specific project for which they were created. without previous written authorization from Monigle Associates, Inc, C Monigle Associates, Inc. 'AII Rights Reserved' 150 Adams Street • Denver, Colorado 80206 ig 7 8' 6' 5' 2 -a\D I 3 ASIDE VIEW SCALE: I/1' -1' -0' RNeeeed Ta BANK OF AMERICA Job Number. 761 Drerrn By. BSC /BRS Deter 09 -04.08 NOTES: SIGN FACE TO 5E.111' CLEAR ACRYLIC (ACRYSTEEL OR APPROVED EQUAL). FIRST SURFACE DECORATE WITH 3M 3632 -20 WHITE CUT TO THE FULL CHARACTER SIZE INCLUDING OUTLINE BASED ON .0228. OVERLAY WITH 3M BOA BLUE (RED AT FLAGSCAPE) FILM CUT TO THE DIMENSIONED CAP HEIGHT. CENTER IN WHITE BACKGROUND FOR EVEN OUTLINE AT PERIMETER SECOND SURFACE DECORATE WITH 3M BOA RED FILM. WEED OUT LETTERS/FLAGSCAPE TO EXTENT OF OUTLINE. OVERLAY ENTIRE SECOND SURFACE WITH 3M DIFFUSER FILM 03(P35-10 WHITE. HEAT BEND RETURNS AT ENDS OF FACE. DO NOT THERMOFORM (IT WILL STRETCH THE FILM AND CAUSE DISCOLORATION ON THE RETURN.) CHEM. WELD CONTINUOUS HANGING BAR AT TOP. SEE DETAIL. CA (n �& n 101/8, ,4810E VIEW SCALE: 1/2' -t' -0' (,J e. +1 Iy0lbs RECEIVED .IAN 2 2 2009 CITY OF FEDERAL. WA'y CDs L r 2. .125' BREAKFORM ALUM. CLADDING / ACCESS PANEL. FORM AS SHOWN. PAINT FINISH CHAMPAGNE METALLIC. SEMI -GLOSS FINISH. ATTACH WITH COUNTERSUNK FLATHEAD STAINLESS STEEL SCREWS. PAINT TO MATCH, 3. O90' ALUM. RETAINER FORM AS SHOWN. PAINT FINISH RED, SATIN FINISH. ATTACH TO CABINET RETURNS WITH COUNTERSUNKFLATHEAD STAINLESS STEEL SCREWS. PAINT TO MATCH. 4. .125' ALUM. CLADDING. FORM AS SHOWN. PAINT FINISH CHAMPAGNE METALLIC. SEMI -GLOSS FINISH. 5. 'BANK OF AMERICA' AND PORTION OF FLAGSCAPE TO BE FIRST SURFACE DECORATED WITH 3M FILM BOA BLUE. SEE DETAIL FOR DECORATION. 6. PORTION OF FLAGSCAPE TO BE FIRST SURFACE DECORATED WITH 3M FILM BOA RED. SEE DETAIL FOR DECORATION. 1. PLACE PRODUCT LABEL HERE. SEE SHEET PL -1 FOR DETAILS. S. U.L. APPROVED EMERGENCY CUTOFF SWITCH WITH WATERPROOF BOOT. S. HOME LOANS TO BE 3M 3632 -20 WHITE FIRST SURFACE APPLIED TO SIGN FACE. t I� GENERAL NOTES: -FINAL SIZING FOR ALL STRUCTURAL MEMBERS (Le, COLUMNS, MATCH PLATES, CONNECTION BOLTS, ANCHOR BOLTS, FOUNDATIONS AND REINFORCEMENT) TO BE SIZED BY A LICENSED ENGINEER TO MEET OR EXCEED ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES. - FABRICATOR IS RESPONSIBLE FOR THE PREVENTION OF ANY LIGHT LEAKS. -LEADS FROM BACK OF ILLUMINATED LETTERS / SYMBOL SHALL BE A MINIMUM OF b' -0' IN LENGTH MEASURED FROM THE BACK SURFACE OF THE LETTERS / SYMBOL. -PAINT INTERIORS OF ALL CABINETS WITH SPRAT -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. -ALL PAINT TO BE TWO -PART POLYURETHANE. -COLOR FILM TO BE MATCHED IN 3M 03632 SERIES FILM. MATERIAL SPECIFICATIONS PAINT - CHAMPAGNE METALLIC - EITHER AKZO -NOBEL ' BNK 250, MATTHEWS - MP 21314, MATTHEWS 'SO4-61945P, OR MATTHEWS'SVOCI212SP (VOC COMPLIANT) -RED - MATTHEWS RED - MP 49696, AKZO -NOBEL "SIGN 20129 -BLUE - MATTHEWS BLUE OMP 216108 6595, -WHITE - MATTHEWS WHITE "MP 216688 6595. FILM -BLUE - 3M - 3632 -8222 -RED - 3M - 3632 -2412 - DIFFUSER - 3M - 3635 -10 -WHITE - 3M0 3632 -20 ACRYLIC -CLEAR ACRYSTEEL AOR APPROVED EQUAL w FILM DEC ORA I N CHANNE LETTE ONLY, LM DE EEL -2441 OR APPROVED EQ. WHITE TRANSLUCENT- ACRYSTEEL ''1328 OR AErRO ygD U . WALL SIGNS Rer No. HLR3.1 Rer No. � MONIGLE I ASSOCIATES Rer No. Rw No. F� ankofAmeri�a %� H� - Im. � ome n s a ° v A NHL —D4r — 2' -3' WALL SIGN a 32 SOTT- SCALE: 1/Y•1' -0' These documents are for design intent and shall be used only as a guide to produce the finished sizes, appearances and functions shovrn. Nothing contained In these documents shall be construed as a design for any engineered element. The fabricator /contractor shall be responsible for all, structural, electrical, mechanical and foundation engineering. See General Specifications for additional requirements. These documents were not produced under an architectural services agreement These drawings a blished design by Monigle Associates, Inc. The detailing and information contained on these pages shall rot be reproduced, copied or utilized except for the specific project for which they were created. without previous written authorization from Monigle Associates, Inc, C Monigle Associates, Inc. 'AII Rights Reserved' 150 Adams Street • Denver, Colorado 80206 ig 7 8' 6' 5' 2 -a\D I 3 ASIDE VIEW SCALE: I/1' -1' -0' RNeeeed Ta BANK OF AMERICA Job Number. 761 Drerrn By. BSC /BRS Deter 09 -04.08 NOTES: SIGN FACE TO 5E.111' CLEAR ACRYLIC (ACRYSTEEL OR APPROVED EQUAL). FIRST SURFACE DECORATE WITH 3M 3632 -20 WHITE CUT TO THE FULL CHARACTER SIZE INCLUDING OUTLINE BASED ON .0228. OVERLAY WITH 3M BOA BLUE (RED AT FLAGSCAPE) FILM CUT TO THE DIMENSIONED CAP HEIGHT. CENTER IN WHITE BACKGROUND FOR EVEN OUTLINE AT PERIMETER SECOND SURFACE DECORATE WITH 3M BOA RED FILM. WEED OUT LETTERS/FLAGSCAPE TO EXTENT OF OUTLINE. OVERLAY ENTIRE SECOND SURFACE WITH 3M DIFFUSER FILM 03(P35-10 WHITE. HEAT BEND RETURNS AT ENDS OF FACE. DO NOT THERMOFORM (IT WILL STRETCH THE FILM AND CAUSE DISCOLORATION ON THE RETURN.) CHEM. WELD CONTINUOUS HANGING BAR AT TOP. SEE DETAIL. CA (n �& n 101/8, ,4810E VIEW SCALE: 1/2' -t' -0' (,J e. +1 Iy0lbs RECEIVED .IAN 2 2 2009 CITY OF FEDERAL. WA'y CDs L r 2. .125' BREAKFORM ALUM. CLADDING / ACCESS PANEL. FORM AS SHOWN. PAINT FINISH CHAMPAGNE METALLIC. SEMI -GLOSS FINISH. ATTACH WITH COUNTERSUNK FLATHEAD STAINLESS STEEL SCREWS. PAINT TO MATCH, 3. O90' ALUM. RETAINER FORM AS SHOWN. PAINT FINISH RED, SATIN FINISH. ATTACH TO CABINET RETURNS WITH COUNTERSUNKFLATHEAD STAINLESS STEEL SCREWS. PAINT TO MATCH. 4. .125' ALUM. CLADDING. FORM AS SHOWN. PAINT FINISH CHAMPAGNE METALLIC. SEMI -GLOSS FINISH. 5. 'BANK OF AMERICA' AND PORTION OF FLAGSCAPE TO BE FIRST SURFACE DECORATED WITH 3M FILM BOA BLUE. SEE DETAIL FOR DECORATION. 6. PORTION OF FLAGSCAPE TO BE FIRST SURFACE DECORATED WITH 3M FILM BOA RED. SEE DETAIL FOR DECORATION. 1. PLACE PRODUCT LABEL HERE. SEE SHEET PL -1 FOR DETAILS. S. U.L. APPROVED EMERGENCY CUTOFF SWITCH WITH WATERPROOF BOOT. S. HOME LOANS TO BE 3M 3632 -20 WHITE FIRST SURFACE APPLIED TO SIGN FACE. t I� GENERAL NOTES: -FINAL SIZING FOR ALL STRUCTURAL MEMBERS (Le, COLUMNS, MATCH PLATES, CONNECTION BOLTS, ANCHOR BOLTS, FOUNDATIONS AND REINFORCEMENT) TO BE SIZED BY A LICENSED ENGINEER TO MEET OR EXCEED ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES. - FABRICATOR IS RESPONSIBLE FOR THE PREVENTION OF ANY LIGHT LEAKS. -LEADS FROM BACK OF ILLUMINATED LETTERS / SYMBOL SHALL BE A MINIMUM OF b' -0' IN LENGTH MEASURED FROM THE BACK SURFACE OF THE LETTERS / SYMBOL. -PAINT INTERIORS OF ALL CABINETS WITH SPRAT -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. -ALL PAINT TO BE TWO -PART POLYURETHANE. -COLOR FILM TO BE MATCHED IN 3M 03632 SERIES FILM. MATERIAL SPECIFICATIONS PAINT - CHAMPAGNE METALLIC - EITHER AKZO -NOBEL ' BNK 250, MATTHEWS - MP 21314, MATTHEWS 'SO4-61945P, OR MATTHEWS'SVOCI212SP (VOC COMPLIANT) -RED - MATTHEWS RED - MP 49696, AKZO -NOBEL "SIGN 20129 -BLUE - MATTHEWS BLUE OMP 216108 6595, -WHITE - MATTHEWS WHITE "MP 216688 6595. FILM -BLUE - 3M - 3632 -8222 -RED - 3M - 3632 -2412 - DIFFUSER - 3M - 3635 -10 -WHITE - 3M0 3632 -20 ACRYLIC -CLEAR ACRYSTEEL AOR APPROVED EQUAL w FILM DEC ORA I N CHANNE LETTE ONLY, LM DE EEL -2441 OR APPROVED EQ. WHITE TRANSLUCENT- ACRYSTEEL ''1328 OR AErRO ygD U . WALL SIGNS Rer No. HLR3.1 Rer No. � MONIGLE I ASSOCIATES Rer No. Rw No. 31g„ VERTICAL SECTION SCALE: 3' •I' -0' 9 10a A 0,> A ^gyp do p� paap .Od C`p Cps. p' dpi `p ~s�p� SECTION SHOWN IS FOR DESIGN INTENT ONLY. SIGN MANUFACTURER TO ENGINEER SIGN FACE AND CABINET TO MEET 150 MPH WIND LOADS (OR HIGHER IF REQUIRED BY LOCAL CODE) WITHOUT FAILING. MANUFACTURER'S DESIGN TO ALLOW FOR SUFFICIENT EXPANSION AND CONTRACTION OF FACE WITHOUT DEFORMATION OR BUCKLING TO FACE. MANUFACTURER'S DESIGN TO PREVENT THE FACE FROM BLOWING OUT OR PUSHING IN AND FROM DEFORMATION AFTER WIND LOADING. CONCRETE FOUNDATIONS, STEEL SUPPORT COLUMNS, STEEL PLATES, ANCHOR BOLTS, ETC. TO BE TYPICALLY DESIGNED FOR 90 MPH WIND LOADS. WHERE LOCAL CODES REQUIRE GREATER WIND SPEEDS, DESIGN THE STRUCTURE TO MEET 150 MPH (OR HIGHER IF REQUIRED BY LOCAL CODES). SIGN MANUFACTURER AND THEIR ENGINEERS TO DESIGN SIGNS TO MEET OR EXCEED ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES. DETAIL r SCALE: 12' 1 NOTES: I. SIGN FACE TO BE .111' CLEAR ACRYLIC (ACRYSTEEL OR APPROVED EQUAL). FIRST SURFACE DECORATE WITH 3M 3632 -20 WHITE CUT TO THE FULL CHARACTER SIZE INCLUDING OUTLINE BASED ON 0228. OVERLAY WITH 3M BOA BLUE (RED AT FLAGSCAPE) FILM CUT TO THE DIMENSIONED CAP WEIGHT. CENTER M WHITE BACKGROUND FOR EVEN OUTLINE AT PERIMETER SECOND SURFACE DECORATE WITH 3M BOA RED FILM. WEED OUT LETTERSiFLAGSCAPE TO EXTENT OF OUTLINE. OVERLAY ENTIRE SECOND SURFACE WITH 3M DIFFUSER FILM 3635 -10 WHITE. HEAT BEND RETURNS AT ENDS OF FACE. DO NOT THERMOFORM (IT WILL STRETCH THE FILM AND CAUSE DISCOLORATION ON THE RETURN.) CHEM. WELD CONTINUOUS HANGING BAR AT TOP. SEE DETAIL. 2. .125' BREAKFORMED ALUM. CLADDNG/ACCESSPANEL. FORM AS SHOWN. PANT FINISH CHAMPAGNE METALLIC. SEMI -GLO55 FINISH. ATTACH WITH COUNTERSUNK FLATHEAD STAINLESS STEEL SCREWS. PAINT HEADS TO MATCH. 3. O90' ALUM. RETAINER FORM AS SHOWN. PANT FINISH RED. SATIN FINISH. ATTACH TO CABINET RETURNS WITH COUNTERSUNK FLATHEAD STAINLESS STEEL SCREWS. PAINT HEADS TO MATCH. 4. .125' ALUM. CLADDING. FORM AS SHOWK PANT FINISH CHAMPAGNE METALLIC. SEMI -GLOSS FINISH. 5.'54NK OF AMERICA' AND PORTION OF FLAGSCAPE TO BE FIRST SURFACE DECORATED WITH 3M FILM BOA BLUE. SEE DETAIL FOR DECORATION. 6. PORTIONS OF FLAGSCAPE TO FIRST SURFACE DECORATED WITH 3M FILM BOA RED. SEE DETAIL FOR DECORATION. 1. 11/2"x 1 1/1 "x 25' ALUM. ANGLE. FRAME. WELD AT CORNERS AS SHOWN. BOLT ATTACH TO STEEL ANGLES WELDED TO STEEL COLUMN AT TOP AND BOTTOM. PAINT FINISH ALL EXPOSED SURFACES WITH SPRAY -LAT STAR BRITS WHITE LIGHT ENHANCEMENT PAINT. RECEIVED JAN 2 2 2009 CITY OF FEDERAL WAY CDS 8. T -12 H.O. DAYLIGHT FLUORESCENT BULB(S) AS REQ'D TO PROVIDE EVEN ILLUMINATION ACROSS SIGN FACE WITHOUT HOT SPOTS OR SHADOWS. USE TOMBSTONE FIXTURES TO EASE SERVICING. 9. UL. APPROVED ELECTRICAL RACEWAY AS REQ'D. 10. .125' ALUM. INTERIOR RETAINER RETURN. FORM AS SHOWN. WELD 3116' ALUM. PLATE AT BASE TO ACT AS RETANER FOR ACRYLIC HANGING BLOCK II. PROVIDE TEFLON TAPE TO INTERIOR OF EXTERIOR RETAINER RETURN TO PROTECT FILM DECORATED FACE FROM SCRATCHING. 12. I'xl'X .125' ALUM. ANGLE INTERIOR RETAINER PAINT FINISH ALL EXPOSED SURFACES WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. 13. .125' ALUM. BACKING SHEET. PANT FINISH EXTERIOR BOA RED. SATIN FINISH. PAINT ALL EXPOSED INTERIOR SURFACES WITH SPRAY -LAT STAR BRITE WHITE LIGHT ENHANCEMENT PAINT. 14. ATTACH TO EXISTING WALL AS REQ'D. 15. .125' BREAKFORMED ALUM. CLADDING. FORM AS SHOWY. PAINT FINISH CHAMPAGNE METALLIC. SEMI -GLOSS FINISH. ATTACH WITH COUNTERSUNK FLATHEAD STAINLESS STEEL 5CREWS. PAINT HEADS TO MATCH, 16. HOME LOANS TO BE 3M 3632 -20 WHITE FIRST SURFACE APPLIED TO SIGN FACE. 11. PROVIDE WEEP HOLES WITH LIGHT SCREENS AS REQ'D. TO MEET U.L. REQUIREMENTS. GENERAL NOTES: -FINAL SIZING FOR ALL STRUCTURAL MEMBERS (I.e. COLUMNS, MATCH PLATES, CONNECTION BOLTS, ANCHOR BOLTS, FOUNDATIONS AND REINFORCEMENT) TO BE SIZED BY A LICENSED ENGINEER TO MEET OR EXCEED ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES. - FABRICATOR 15 RESPONSIBLE FOR THE PREVENTION OF ANY LIGHT LEAKS. -LEADS FROM BACK OF ILLUMINATED LETTERS SYMBOL SHALL BE A MINIMUM OF 6' -0' IN LENGTH MEASURED FROM THE BACK SURFACE OF THE LETTERS / SYMBOL. -PAINT INTERIORS OF ALL CABINETS WITH 5PRAY -LAT STAR 15RITE WHITE LIGHT ENHANCEMENT PAINT. -ALL PAINT TO BE TWO -PART POLYURETHANE. -COLOR FILM TO BE MATCHED IN 3M 3632 SERIES FILM. MATERIAL SPECIFICATION5 PAINT - CHAMPAGNE METALLIC - EITHER AKZO -NOBEL " BNK 250, MATTHEWS " MP 21314, MATTHEWS OSOA61945P, OR MATTHEWS $SVOC12125P (VOC COMPL [ANT) -RED - MATTHEWS RED " MP 496961 AKZO -NOBEL $SIGN 20129 -BLUE - MATTHEWS BLUE TIP 216108 6595, -WHITE - MATTHEWS WHITE "MP 216688 6595. FILM -BLUE - 3M " 3632 -8222 -RED - 3M ' 3632 -2412 - DIFFUSER - 3M • 3635 -10 -WHITE - 3M" 3632 -20 ACRYLIC -CLEAR ACRYSTEEL "OR APPROVED EQUAL F LM D TION CHANNEL L TT ONLY ACRYSTEEL 02441 OR APPROVED EQ. WHITE TRANSLUCENT - ACRYSTEEL 01328 OR A Q I WALL SIGN DETAIL These documents are for design intent and shall structural, electrical, mechanical and foundation information contained on these pages shall not be Released To. BANK OF AMERICA per No. HLR3.5 be used only as a guide to produce the finished sizes, appearances and functions shown. Nothing engineering, See General Specifications for additional requirements. These documents were not produced reproduced, copied or utilized except for the specific project for which they were created, without previous 'leblN*w. 761 • Rer No. MONIGLE ASSOCIATES contained In these documents shall be construed ender an architectural services agreement. These written authorization from Monigle Associates, Inc. `All Drawn By. BRS FRev Nm as a design for any engineered element. The fabricator /contractor shall be responsible for all drawings are part of an original unpublished design by Monigle Associates, Inc. The detailing and V Monigle Associates, Inc, Rights Reserved' 150 Adams Street - Denver, Colorado 80206 F Date. 1 09.01 -08 FR@v No.