Loading...
15-105617e D f� City of Federal Way Community & Econ. Dev. Services 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835 -2607 Fax: (253) 835 -2609 Project Name: RITE AID Project Address: 2131 SW 336TH ST _ Sign Permit #: 15- 105617 -00 -SG Inspection Request Line: (253) 835 -3050 Parcel Number: 873217 0030 Project Description: Install (2) internally illuminated cabinet wall mounted signs. To attach to existing Xbox. Reface (1) existing non - illuminated, double faced monument signs. Sign area only. Owner A n� licant Contractor RITE AID CORPORATION LESLIE RUNYON TBD - NOT YET SELECTED PO BOX 3165 SIGN ART INC Sign A HARRISBURG PA 17105 5757 E CORK ST Yes 1 KALAMAZOO MI 49002 5.17 Wall Sign Information Additional Permit Information Comprehensive Plan Designation ........ ..................Neighborhood Zoning Designation ............................................... BN Business PERMIT EXPIRES Wednesday, July 6, 2016 Permit Issued on Friday, January 8, 2016 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: F�NA�EO Reg. # Sign Type Illuminated # Sign Faces Sign Face Width (Ft) Sign Face Height (Ft) Building Elevation Sign A NA Cabinet Yes 1 24.75 5.17 North Sign B NA Cabinet Yes 1 5.00 1.08 North Additional Permit Information Comprehensive Plan Designation ........ ..................Neighborhood Zoning Designation ............................................... BN Business PERMIT EXPIRES Wednesday, July 6, 2016 Permit Issued on Friday, January 8, 2016 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: F�NA�EO Can oJ Federal Way PERMIT #: THIS CARD IS TO REMAIN ON -SITE , Construction Inspection Record INSPECTION REQUE TS: (253) 835 -3050 15- 105617 -00 -SG Address: 2131 SW 336TH ST Project: RITE AID CORPORATION FEDERAL WAY, WA 98023 -2847 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. Footings /Setback (4110) Final - Electrical (4055) Final - Sign (4085) Approved to place concrete Approved Approved By Date B Date �_ �� (� ByN-S, Date e -z (� Attachment (4010) Approved Date 0 _Z3 - ( (o Rough Electrical Approved Final Electrical Approved Right of Way Approved By Date By Date By Date Plea 0.5 _S CITY OF 5��� ��RMIT Federal Way To c ,A PQN D tMk' PROPERTY 0 •. • SITE ADDRESS Twin Lakes, 2131 SW 336th St., Federal Way, WA 98023 -2898 SUITE /UNIT # ASSESSOR'S TAX /PARCEL # 8 7 3 2 1 7- 0 0 3 0 ZONING DESIGNATION NB TYPE OF PROJECT (Check all that apply): ❑ NEW ALTERATION ❑ REFACE ❑ EXEMPT 1g ELECTRICAL (To attach to existing J -box - include on this permit) ❑ ELECTRICAL (New /altered circuit & J -box added - separate permit is required) NUMBER OF SIGNS APPLIED FOR WITH THIS APPLICATION: Wall Mounted: 3 Freestanding: TOTAL ESTIMATED PROJECT COST: $ 6,931 DETAILED PROJECT DESCRIPTION: Replace existing 'Rite Aid' channel letters with new 'RITE AID' all uppercase letters, install aluminum RediClinic /MultiCare window sign, replace attribute bullet face only BUSINESS NAME ON SIGN: PEOPLE •' • SIGN OWNER: NAME: PRIMARY PHONE CONTRACTOR: APPLICANT COMPANY NAME TBD APPLICANT NAME Mitchell Noftsger, Rite Aid Corporation ( 717) 236-4208 MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP): FAX NUMBER 2013 N Third Street, Harrisburg, PA ( ) - CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: E -MAIL ADDRESS Kalamazoo MI 49048 Mitchell. Noftsger @riteaid.co COMPANY NAME TBD APPLICANT NAME OFFICE PHONE ( ) - MAILING ADDRESS (STREET ADDRESS; CITY, STATE, ZIP): CELL PHONE CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: EXPIRATION DATE: FAX NUMBER CONTRACTOR'S REGISTRATION NUMBER: EXPIRATION DATE: E -MAIL ADDRESS COMPANY NAME APPLICANT NAME PRIMARY PHONE Si nArt Inc. Leslie Runyon ( 269) 381-3012 MAILING ADDRESS CITY, STATE, ZIP FAX NUMBER 5757 East Cork Street Kalamazoo MI 49048 ( 269) 381 - 0999 RELATIONSHIP TO PROJECT E -MAIL ADDRESS Contractor ❑ Tenant ❑ Other PROJECT NAME PRIMARY PHONE E -MAIL ADDRESS: CONTACT Leslie Runyon ( 269) 381-3012 Irunyon @signartinc.com N SIGNATURE I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and further, that I am authorized by the owner of the above premises to perform the work for which the permit application is made SIGNATURE DATE: 9 -29 -15 COMMUNITY DEVELOPMENT SERVICES • 33325 8"" TM AVENUE SOUTH • FEDERAL WAY, WA 98003 -6325 • 253 - 835 -2607 • FAX: 253 - 835 -2609 PERMANENT FREE STANDING: MONUMENT PEDESTAL POLE TENANT DIRECTORY OTHER OTHER (Describe) PERMANENT BUILDING MOUNTED: AWNING V CABINET CHANNEL LETTERS TENANT DIRECTORY OTHER (Describe) FREE STANDING SIGNS MOUNTED SIGNS SIGN TYPE SIGN AREA (SQ.. FT.) ILLUMINATED? REFACE? TOTAL HEIGHT BASE HEIGHT (FT) REGISTRATION NUMBER: REGISTRATION NUMBER: WIDTH x HEIGHT x # OF FACES NO / INT / EXT YES / NO FT A A T � 1-2 3/4" x 3 -0 x 1 = 51.69 INT No North 172 x 9 = 1548 sq ft B Attribute 24' -9 -2., 53.63 1 INT - sign to 172 x 9 = 1548 s ft q bullet sin x _2 x _ be refaced only— North B C Hanging window cabinet 5' -0 x_1'-1" x 1 = 5.42 INT North 172 x 9 = 1548 sq ft D x x – C x x – E x x – x x – STREET FRONTAGE (LINEAR FEET): BUILDING MOUNTED SIGNS BUILDING MOUNTED SIGNS SIGN TYPE SIGN AREA (SQ. FT.) ILLUMINATED? BUILDING ELEVATION EXPOSED BUILDING FACE REGISTRATION NUMBER: REGISTRATION NUMBER: WIDTH x HEIGHT x # OF FACES NO /INT /EXT N,S,E,W (S Q. FT. A Channel letter T � 1-2 3/4" x 3 -0 x 1 = 51.69 INT No North 172 x 9 = 1548 sq ft B Attribute 24' -9 -2., 53.63 1 INT - sign to 172 x 9 = 1548 s ft q bullet sin x _2 x _ be refaced only— North C Hanging window cabinet 5' -0 x_1'-1" x 1 = 5.42 INT North 172 x 9 = 1548 sq ft D x x – E x x – LARGEST EXPOSED BUILDING FACE (SQUARE FEET): 1548 sq ft * *FOR OFFICE USE ONLY ** ZONING DESIGNATION: PROFILE: ❑ HIGH ❑ MEDIUM ❑ LOW ❑ FREEWAY BUILDING MOUNTED SIGNS FREE STANDING SIGN (S) AREA PERMITTED: AREA PROPOSED: LARGEST BUILDING FAIgADE: NUMBER OF SIGNS ALLOWED: AREA PERMITTED: AREA PROPOSED: STREET FRONTAGE: NUMBER OF SIGNS ALLOWED: LAND USE APPROVAL BY: DATE: STRUCTURAL APPROVAL BY: DATE: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: Bulletin #102 — January 1, 2011 Page 2 of 4 k:/Handouts /Sign Permit Application ��ut7iLL Gill Ella GOelad IuawnuoA )R u61S IIeM IaaJIS UI9`✓9 MS LOLL E)S-00-L L990 L-5 L 31170 io3road SS�jdacv # ll A �J-Dd RITE =j AID *FINAL INSPECTION REQUIRED TE 1ki D Store #05186 2131 SW 336th St. Federal Way, WA, 98023 gnArt Inc., 5757 E. Cork S 17 i Eoo, 1 9048 11,117, Sign Code Approved: Date: / t� / .ZOOS City of Fede ml Way Building Division P P1 0 IM D FOR CON SIM, U C111. PA q -lip -��' Electrical work to be performed under a separate permit issued by City of Federal Way, contact Permit Center 253 - 835 -2607 A 2012 IBC section 110.1 General Construction or "ork for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain accessible and exposed for inspection purposes until approved Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction Inspections presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid It shall be the dutv of the permit applicant to cause the work to remain accessihle and exposed for inspection purposes. Neither the building official nor the jurisdiction shall he liable for expense entailed in the removal or replacement of anv material required to allow inspection RECEIVED NOV 0 4 2015 CITY OF FEDERAL WAY CDS 269.381.3012 signartinc.com Site Plan Scale: None NOV 0 4 2015 Rite Aid #5186 — 2131 SW 336th St., Federal Way, WA CITY OF FEDERAL WAY _ _ rn; This is an original unpublished drawing, submitted for your use in connection with a project being planned for you by SignArt. It is not to be reproduced, copied or exhibited in any fashion without written permission of SignArt. ©201 5 ED 09 -17 -15 10- 26 -15DL Approved for: __ By: Date: Lead #LR -1398 WA,ra5186a XSi gTAft ELEVATION 9'-0-- 3-0 1/211 - . t.T 21-211 121-211 Existint! Elevation Scale: '/16" - 1'-0-- ----------- �721-011 I - 241-911 1 eq I -eql�j Sign #1 A Sign #2 B Proposed Elevation Scale: 1/16" - 1'-0-- Note: Vertical spacing to be verified. RECEIVED NOV 0 4 2015 CITY OF FEDERAL WAY Pifi- Aid #51 86 — 2131 SW 336th qt Fpcit-rA Way, W CDS .f I f phis is an original unpublished drawing, submitted for your use in connection with a project being planned for you by SignArt. It is not to be reproduced, copied or exhibited in any fashion without wrillen permission of SignArt. Lead #LR-1398 @2015 WA,ra5186a ED 09-17-15 10-26-15DL Approved for: By: Date: i V31_011 /2u 2' -2" 24' -9" eq eq Proposed Elevation Note: Vertical spacing to be verified. 9' -0" 23'-0'� - 11 ' -2 "� 172' -0" - 24' -9" RITE AID Partial Front Elevation �–eq– f–eq -1 i Scale: 1/32" = 1'-0" Scale: 1/8" - V -0" Square Footage 'Rite Aid' T -0" x 17'- 23/4" = 51.69 Sq.Ft. Bullet Sign 2' -2" x 24'-9" = 53.63 Sq.Ft. Building Facade 9' -0" x 172' -0" = 1,548 Sq.Ft. RECEIVED NOV 0 4 2015 CITY OF FEDERAL WAY Rite Aid #5186 — 2131 SW 336th St., Federal 1A/- CDs Lead #LR -1398 This is an original unpublished drawing, submitted for your use in connection with a project being planned for you by SignArt. It is not to be reproduced, copied or exhibited in any fashion without written permission of SignArt. ©201 5 WA,ra5186a ED 09 -1 -15 10- 26 -15DL Approved for: By: _ Date: Rite Aid #5186 511 II 3' -0" 17'-23/x' i _. 91 -011 _. _ 71- 33/411 i 7 Sign #1 A — Illuminated Channel Letters Scale: ' /a" = V -0" 'RITE AID' 'PHARMACY' — 5" Deep, .040 aluminum returns painted GripGard Plus semi -gloss to match #2870 blue with .050 aluminum backs. Faces to be flat clear polycarbonate overlaid with blue dual -color film with diffuser film applied to second surface and matching 1" blue trim cap. Letters to be illuminated using a white LED system powered by low voltage power supplies. 2131 SW 336th St., Federal Way, WA Square Footage 'Rite Aid' 3' -0" x 17- 23/4" = 51.69 Sq.Ft. 'Rite Aid' 21 Ibs x 7 = 1501bs Sign to bear these marks. &ELECTRIC LISTED SIGN This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. RECEIVED NOV d 4 2015 CITY OF FEDERAL WAY CDS This is an original unpublished drawing, submitted for YOUr ue in connection with a project being planned for you by SignArt. It is not to be reproduced, copied or exhibited in any fashion without written permission of SignArt. ED 09 -17 -15 10- 26 -15DL Approved for: By: Lead #LR -1398 ©2015 WA,ra5186a Date: a-211 71/211 - 24' -9" - verif ) '_6" Sign #2 B — Replacement Routed Face for Illuminated Bullet Sign Scale: 1/4" = 1' -0" Existing sign faces to be removed and replaced with new precision- routed .100 aluminum faces painted GripGard Plus semi -gloss to match #2870 blue. Faces to be backed with flat white polycarbonate. RediClinic graphic is to be digitally printed on clear pressure sensitive vinyl with UV overlaminate applied to polycarbonate backing and showing through precision- routed circle in aluminum face. Existing cabinet to be scuffed, degreased and painted GripGard Plus semi -gloss to match #2870 blue. Relamp as needed. 2' -2" x 24' -9" = 53.63 Sq.Ft. Replacement face = 15lb s. RECEIVED NOV 0 4 2015 CITY OF FEDERAL WAY Rite Aid #5186 — 2131 SW 336th St., Federal Way, WA This is an original unpublished drawing, submitted for your use in connection with a project being planned for you by SignArt. It is not to be reproduced, copied or exhibited in any fashion without written permission of SignArt S,G�n A 6 Comb neck Exposed Bldg Faces q.ft. Sign Area Allowed s4 c sq.ft. Sien Area Proposed i 2-7 el k' sa.ft. Lead #LR -1398 ©2015 WA,ra5186a ED 09 -1 -15 10- 26 -15DL Approved for: By: -__ _ _ __ _ Date: Existing Elevation Scale:' /8" =1'-- 0" Sign #3 C 1' -1" -JM& r IAP .. Proposed Elevation Scale:' /8" =I'- 0" Note: Vertical hanging support length from ceiling to be verified to achieve sign visibility without interfering with existing'Welcome' on window. RECEIVED NOV 04 2015 CITY OF F' 7—RAL WAY Rite Aid #5186 — 2131 SW 336th St., Federal Way, WA CDs This is an original unpublished drawing, submitted for your use in connection with a project being planned for you by SignArt. It is not to be reproduced, copied or exhibited in any fashion without written permission of SignArt. ©2015 ED 09 -17 -15 10- 26 -15DL Approved for: By: Date: Lead #LR -1398 WA,ra5186a 2' -0" 5' -0" - 1' -0" 31-011- 11-011 eq • • . in affiliation with � 41/2" dlClinir M eq. -t� Sign #3 C — Illuminated Window Cabinet Sign Exposed Bldg Face sq.ft. Sign Area Allowed - sq.ft. Sign Area Pronosed 7. 'A'-)-- soft. Scale: 1 " = 1'4" Square Footage 1' -1" x 5' -0" = 5.42 Sq.Ft. Sign cabinet = 12lbs. Signs to bear this mark. @ELECTRIC LISTED SIGN This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. Low - voltage PS raceway in ceiling with disconnect and wired to sign thru PVC sign support cable sheathing. Sign to be supported by cables run through ceiling tile and clamped to 4' -6" aluminum angle spanning over ceiling. Cables to be sheathed in ' /z" PVC painted GripGard Plus semi -gloss to match Turkish Coffee. See note on elevation about vertical verification. Ceiling. Custom fabricated sign cabinet with 1" retainers and 5" deep returns painted GripGard Plus semi -gloss to match SW #6076 Turkish Coffee. Face to be flat white polycarbonate with digitally printed graphics, logos and copy for'RediClinic' and 'in affliliation with MultiCare' on clear pressure sensitive vinyl with UV overlaminate. Sign to be illuminated using white LEDs powered by low - voltage power supply. RECEIVED NOV 0 4 2015 CITY OF FEDERAL WAY A Rite Aid #5186 — 2131 SW 336th St., Federal Way, WA Lead #LR -1398 This is an original unpublished drawing, submitted for your use in connection with a project being planned for you by SignArt. It is not to be reproduced, copied or exhibited in any fashion without written permission of SignArt. ©2015 WA,ra5186a ED 09 -17 -15 10- 26 -15DL Approved for: By: _ Date: Existing Elevation Scale: None Sign #4 D Proposed Elevation Scale: None Note: Existing cabinet - to be refaced only. RECEIVED NOV 0 4 2015 CITY CF r7-^F.:RAL WAY Rite Aid #5186 — 2131 SW 336th St., Federal Way, WA cam.D Lead #LR -1398 This is an original unpublished drawing, submitted for your use in connection with a project being planned for you by SignArt. It is not to be reproduced, copied or exhibited in any fashion without written permission of SignArt. ©2015 WA,ra5186a ED 09 -17 -15 10- 26 -15DL Approved for: By: Date: w eq. t- 101/2" RITE AID D 4' S4" PHARMACY t- 71/2" 83/4, %,0`Rec1*iC1inic eq. Sign #4 — Replacement Face for Illuminated Monument Scale: 3/4" = 1' -0" Face to be flat white polycarbonate with #2870 blue and #156 green pressure sensitive vinyl applied to first surface reading 'RITE AID PHARMACY' and 'RediClinic'. RediClinic graphic to be digitally printed on clear pressure sensitive vinyl with UV overlaminate. Note: Existing sign cabinet and retainers sizes to be verified. Square Footage 4' -0" x 5-10" = 23.33 Sq.Ft. v Exposed Bldg FacE _sq.ft. Sign Area Allowed_sq•ft. Sien Area Pr000sed l'� i soft. Rite Aid #5186 — 2131 SW 336th St., Federal Way, WA Lead #LR -1398 This is an original unpublished drawing, submitted for your use in connection with a project being planned for you by SignArt. It is not to be reproduced, copied or exhibited in any fashion without written permission of SignArt. ©2015 WA,ra5186a ED 09 -17 -15 Approved for: _ By: Date: RECEIVED l.in\l 0 d 7015 CITY OF FEDERAL- WAY CDS C Illuminated Channel Letter Detail 0) .040 Aluminum letter sides painted GripGard semi -gloss to match SW 6076 Turkish Coffee. O2 1" Jewelite trim cap painted to match SW 6076 Turkish Coffee with #8 x' /z" hex head screws as needed. O3 Flat white polycarbonate faces. O4 G.E. Tetra MAX LED system. 5O Low voltage wiring from power supply. �6 Pre- drilled low voltage electrical hole with 3 /a" plastic grommet. O'/4" Weep holes at low points of letters with internal light baffle. 8O .050 Aluminum letter back. Letter sides and backs stitched together and continuously siliconed. O9 Building facade; exact construction to be verified. 10 Vertical stud by others. 11 20 Amp toggle disconnect (actual location to be on end of raceway, shown on top for drawing purposes only). 12 4" x 8" x 18" J IC box. 13 Low voltage (12 volts) G.E. #GEPS12 -60 LED power supplies (120 volt circuit required). 14 Secondary wiring low voltage connection to LED's with #054007 -06128 Scotchlok connectors. 15 Ground wire permanently fixed to power supply box. 16 '/2" Sealtite connector. 17 UL listed Belden #9409 1 PR18 AWG wire. 18 '/z" Sealtite conduit. 19 #12 THHN electrical primary wiring. White — Neutral Black — Feed Green — Ground 20 Letters mounted to facade with 3/8' stainless steel threaded rod, washers and nuts as needed. Exact fastener to vary with different facade /building construction. Note: All penetrations to be sealed with 3M #1000 NS Fire Barrier, water tight, non -slump silicone sealant to meet NEC #300.21, ASTM #E814, UL #1479 & UL #R2�@r4fflWards. Building dimensions and construction of facade to be verified by sign installer prior to installation of signs. rn\i a 4 2015 Scale: 2" = 1' -0" Rite Aid #5186 — 2131 SW 336th St., Federal Way, WA CITY OF FEDERAL WAY Inc This is an original unpublished drawing, submitted for your use in connection with a project being planned for you by SignArt. It is not to be reproduced, copied or exhibited in any fashion without written permission of SignArt. ©201 5 ED 09 -17-15 10- 26 -15DL Approved for: By: Date: Lead #LR -1398 WA,ra5186a