02-104724 Vet Ali it 0( 7 • rCity ew op a t Services Building - Single Family Permit #:02 - 104724 - 00 - SF ay S,WA 98003-6210 4000 Fax:253.661.4129 Inspection request line: 253.835.3050 ame: MCKASY dress: 31002 39TH AVE SW Parcel Number: 758200 0100 Project Description: RES REP-Structural repair work to portion of roof over living room area in existing residence to correct deflections in roof,subject to field inspection. Owner Applicant Contractor Lender Michael J McKasy INNERSTATE CUSTOM ROOFING INNERSTATE CUSTOM ROOFING Michael J McKasy 31002 39TH PL SW 8405 JOHN DOWER RD SW INNERCROO5DC 3/3/04 31002 39TH PL SW FEDERAL WAY WA LAKEWOOD WA 98499 8405 JOHN DOWER RD SW FEDERAL WAY WA 98023-2179 LAKEWOOD WA 98499 98023-2179 Includes: Census category: 434-Reside #1 #2 #3 #4 Occupancy Group: R-3 Construction Type: Type V-N Occupancy Load: Floor Area(Sq.Ft.): Census Category 434-Residential alt/add-no. Mechanical No Occupancy Group#1 R-3 Plumbing No Zoning Designation RS 15.0 CONDITIONS: 1.This decision shall not waive compliance with future City of Federal Way codes,policies,or standards relating to the subject proposal. PERMIT EXPIRES April 22,2003,IF NO WORK IS STARTED. Permit issued on October 24,2002 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws,rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: / Date: 44 2 II OS f POST THIS CARD ON THE FRONT OF BUILDING • BU DING DIVISION • uV AY INSPECTION RECORD INSPECTION REQUEST PHONE#: 253-835-3050 PERMIT#: 02-104724-00-SF OWNER'S NAME: Michael J McKasy SITE ADDRESS: 31002 39TH SW ( ) FOOTINGS/SETBACKS ( ) FOUNDATION WALL a °m D( OT POUR CONCRETE UNTI MATE"ABOVE TS APPROVED ( ) DRAINAGE: Line ( ) Connection NOT°POUR SLAB UNTIL THE ABOVE"IS{APPROVED 17 ( ) UNDERFLOOR FRAMING ( ) ROUGH PLUMBING: DWV Water piping ( ) ROUGH MECHANICAL Gas piping ( ) SHEATHING Roof Floor ( ) SHEAR WALLS ( ) ELECTRICAL ROUGH-IN Ditch Cover ( ) FIRE/DRAFTSTOPS ALLTHEuABOVE MUST BE APPROVED PRIOR TO FRAMING INSPECTION ( ) FRAMING/FIRESTOPPING_ / P4" •/ 49/05 e 45 7-7-1MitAilE ABOVE MUST BE APPROVED PRIOR TO INSULATINGOR SHEETROCKING ( ) INSULATION: Floors Walls Attic .THE ABwOWMUST BE APPROVED PRIOR TO APPLYING SHEETROCK () WALLBOARD NAILING () SUSPENDED CEILING THE�'AROVE MUST-BE APPROVED'PRIOR TO TAPING.OR INSTALLING CEILING TILE () ELECTRICAL FINAL () PLANNING FINAL ( ) PUBLIC WORKS FINAL ( ) FIRE FINAL 0THEABOVE MUST BE APPROVED PRIOR TO BUILDING DEPARTMENT FINAL ( ) BUILDING FINAL DO NOT OCCUPY THIS BUILDING UNTIL BUILDING FINAL IS APPROVED 1 .1111 II CRY CONSTRUCT I ION PERMIT APPLICATION uV fIylZf3L RECEIVED APPLICATION NUMBER: d Z- 4.047 .? Qo w OCT 4 2002 APPLICATION NUMBER: ' APPLICATION NUMBER: - V *OtX�E€j�I RAL WAY — — — — — — — — — BUitoWl N rPe`•I�red information—Please print(in ink)or type** Please note: Electrical,Fire Prevention Systems and Engineering I y g' g permits may require a separate application. . • PROPERTY INFORMATION SITE ADDRESS: 31 CX z.. 31 446 s.cJ• ••SSOR'S TAX/PARCEL#: J rz---o 3 - 0( xx �S� { LEGAL DESCRIPTION OF SUBJECT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY): . -. - ..1 'PROJECT INFORMATION - TYPE OF PROJECT(This application): ❑ BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION El ELECTRICAL Cl ENGINEERING❑ FIRE PREVENTION SYSTEM • PROJECT DESCRIPTION(Provide detailed description): _ 1ba 0 I444S tie 12e0P IP4t64 ( c le__ LA N!'c LS to ... ba. , Q. PROJECT NAME: LA • , . • PEOPLE INFORMATION T:. PROPERTY OWNER: NAME: � a/�/� L DAYTIME PHONE: ll V._•„ .4— �... - _ ..A ( ) - ADDRESS Z DDRESS(SIRE ADDRESS*CITY, ATE,ZIP): MAI N.000. 1 4:" AAA'` s W • b1$ tip Pe a/JT- 1W CONTRACTOR: NAME: � ` DAYTIME PHONE: ¢sqk 4 C s w� 12•454)1'4,4(11 (2SS)G9. ( -o vie. MAI<NG ADDRESS(S ST�REEE EEETTi��ADDRESS;CITY,STATE,ZIP): EVENING PHONE: 4 �SWAY BUSINESS LICENSE NUMBS �tO S. • � FAX : -64ig _ - ( ) CONTRACTOR'S REGISTRATION NUMBER: EXPIRATION DATE: (copy of card required) e C C pc w 03/b8 /f /y,4 APPLICANT: NAME: I •"' G a-CIF-Op S a C �w II • wE �g DAYTIME PHONE: MAILING ADDRESS(STREET ADD ;CITY,STATE,ZIP): -C • ' EVENING f O j 63-5- ve4.,Lr- 4a i. tAied ( )9I -et?ir RELATI NSHIP TO PROJECT: FAX BER: CI ARCHITECT CI TENANT ❑ OTHER(DESCRIBE): CONTILACITINC% ( ) - E-MAIL ADDRESS: CONTACT PERSON FOR THIS PROJECT: ❑ PROPERTY OWNER ❑ APPLICANT CONTRACTOR • DETAILED BUILDING INFORMATION V EXISTING USE: EXISTING BUILDING ASSESSED/APPRAISED VALUATION $ PROPOSED USE: PROPOSED VALUATION FOR IMPROVEMENTS: $ GI IrSb SPRINKLERED BUILDING? ❑ YES ❑ NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED:❑ YES ❑ NO WATER SERVICE PROVIDER: El LAKEHAVEN ❑ HIGHLINE El TACOMA ❑ PRIVATE(WELL) SEWER SERVICE PROVIDER: ❑ LAKEHAVEN El HIGHLINE El PRIVATE(SEPTIC) **NEW RESIDENTIAL CONSTRUCTION ONLY** NUMBER OF BEDROOMS: ESTIMATED SELLING PRA. $ • PRO3ECT FLOOR AREAS FLOOR EXISTING SQ.FT. PROPOSED SQ.FT. TOTAL BASEMENT FIRST • • • SECOND THIRD • FOURTH OTHER FLOORS(DESCRIBE) DECK GARAGE HOW MANY FLOORS? TOTAL: .0, .r, +»+p +w•w..5+•:,,,•�•:;sWC2'' /°'oxlra{suxRiriyx faY`�I t f FIXTURES•x4;,.6:ca!V;i-1,,ii..r......fqni mrna...si s,,!t :7tr'Si"�a:c+av'da Via.. Indicate number of each type of fixture MECHANICAL AIR HANDLING UNIT(S) EVAPORATIVE COOLER(S) GAS LOG(S) REFRIG.SYSTEM(S) BBQ(S) FAN(S) HOOD(S) WOODSTOVE(S) BOILER(S) FIREPLACE INSERT(S) RANGE(S) MISC.( ) COMPRESSOR(S) FURNACE(S) DUCT(S) GAS PIPE OUTLET(S) HEAT SOURCE: ❑ ELECTRIC ❑ GAS PLUMBING BATHTUB(S) LAVATORY(S) URINAL(S) WATER HEATER(S) DISHWASHER(S) RAIN WATER SYS. VACUUM BREAKER(S) ❑ ELECTRIC ❑ GAS DRINKING FOUNTAIN(S) SHOWER(S) WASH MACHINE OUTLET GAS PIPE OUTLET(S) SINK(S) WATER CLOSET(S) MISC.( ) INTERCEPTOR(S) SUMP(S) • ` ■"DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of Federal Way as to any daim(induding costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,induding the undersigned,and filed against the City of Federal Way,but only where such daim arises out of the reliance of the city,induding its officers and employees,upon the accuracy of the information supplied to the city as a part of th" application. NAME/TITLE: �� f DATE: /1) •Ze''' ❑ PROPERTY OWNER ❑ APPLICANT re ONTRACTOR FOR°OFFICE:USE ONLY , EW ❑aADD TION,�,, .®,ALTERATION: .,L REPAIR r}, ❑iTENANTIMPROVEMENTK .z_:. t OhNING, E;IC TYON,4., ER-Ill '. BUILDINGSHELLONLY?„ ❑fYES,r`,x`® COMP I DESIGNATION 442-zx ;t W4*-11BASIC PLAN' %ESA .' NO ' tt °`3'l #SECTION_ ' TOWNSUIP`? RANGE : ` _NEW ADDRESS,REQUIRED?'--,. .[1 YES D NO fPLATTEI)LOT? ❑,YES a❑ NO.' COMMUNITY DEVELOPMENT SERVICES•33530 FIRST WAY SOUTH•PO BOX 9718•FEDERAL WAY,WA 98063-9718•253-661-4000•FAX:253-661-4129 www.cftYOfIedera lwaY.Com f 1 0 northwest inspection engineers 333 RAINIER AVE. N., SUITE 101 /RENTON,WASHINGTON 98055 • TELEPHONE (425) 228-5975 SUBJECT TO FIELD INSPECTION. RECEIVED October 24, 2002 OCT 2 4 2002 Int,ction Report CITOILDING DEPT, AY BU 31002 39`'Avenue S.W., Dash Point, Washington For the exclusive use of: Margaret and Michael Mc Kasy Date of Inspection: October 23, 2002 Inspecting Engineer: Jack A. Swardz,P.E. INTRODUCTION The purpose of this inspection was to evaluate sags in the roof structure, to the extent that a reasonable amount of time and conditions permit. The initial presumption is that all elements are adequate and proper. Statements, representations or conclusions to the contrary are made only when the inspecting engineer sees evidence which, in his judgment, indicates the existence of significant deficiencies. The inspection is visual only and does not involve the opening or exposure of elements concealed from view. Wherever a deficiency of any kind is identified in this report, there is always a possibility that it is associated with a larger, more serious, more extensive or more pervasive problem that is hidden from view or is beyond the scope of this inspection. Consequently, you should take whatever action is necessary to ensure that the full extent and implications of identified deficiencies are known. To fully understand the importance of any deficiency, you should obtain bids for its correction. Bids for repairs vary widely,with high bids sometimes being five to ten times the amount of low bids for the same work. You should always obtain at least three competitive bids. Certain limitations apply to any inspection, including those diligently performed by a qualified expert. The limitations on this inspection include any noted in the body of the report together REAL ESTATE INSPECTION BY REGISTERED PROFESSIONAL ENGINEERS Engineer's Inspection of the Property Located At 31002 39th Avenue S.W., Dash Point, Washington Page 2 with those listed under "Limitations on Inspections" at the end of the report. We consider these limitations unavoidable. If you make any use of the information contained in this report, it is necessary that you understand and accept these limitations. IF THESE LIMITATIONS ARE UNACCEPTABLE TO YOU, YOU SHOULD NOT RELY ON THE INFORMATION IN THIS REPORT FOR ANY PURPOSE WHATSOEVER. EVALUATIONS The roof structure over the living room has been opened for evaluation. The roof structure is constructed of 2x8 rafters, spaced on 24 inch centers, spanning about 17 feet. This is too long of a span for 2x8's. I recommend that 2x10's be used in any areas that the spans exceed 12 feet 7 inches. The 2x 10's can be placed midway between the existing rafters to form a system on 12 inch centers or be sistered to the existing rafters, but the new 2x 10 rafters will require creative notching to maintain the existing top face roof elevation and providing proper bearing on the support beams. The out-looker beams must be securely anchored to the building and new 2x10 outboard rafters be shimmed or otherwise modified to reduce the sag. The rafters on either side of the chimney should be doubled and a good header be placed on the up-hill side of the chimney to support rafters in the area that abuts the chimney. LIMITATIONS ON INSPECTIONS The limitations on this inspection include those discussed throughout the report, together with those listed in the following paragraphs. ACCESSIBILITY OF DEFICIENCIES: Statements, representations, or conclusions offered by the engineer who conducts the inspection and/or by Northwest Inspection Engineers, Inc. are based solely upon a visual examination of the exposed areas of the structure inspected. Hidden defects could have a significant impact on the visually based conclusions, statements, and representations made by the inspector. NO WARRANTY: All statements, representations, or conclusions offered by the inspecting engineer are the considered opinion of the inspecting engineer arising from the limited inspection • Engineer's Inspection of the Property Located At 31002 39th Avenue S.W., Dash Point, Washington Page 3 described herein. These statements, representations, or conclusions do not constitute an express or implied warranty of any kind. S Jo o�W's1►i 4i bilk" 44° frOCW . 1414 ` • ill140111 , /,o Z. x0 YGA33 RWAL wows W15/ COPYRIGHT © 2002 NORTHWEST INSPECTION ENGINEERS,INC. (NIE) This report and the information contained in it are the property of NIE. Use is restricted to only the client named In the report. Use by other persons or reproduction without permission of NIE is prohibited. •