Loading...
08-103551'Of Fedpi­4 CommunityDeveop mini Services Buildi*- Single Family Permit 1008-1,035M. ad F P.O. Box 9718 Federal Way, WA 98063-9718 Ph: (253) 835-2607 Fax: (253) 835-2609 Inspection Request Line: (263) 835-3050 Project Name: BRIGHTON PARK LOT 12 e'er Project Address: 36423 10TH CT SW q Parcel Number: 111263 0120 Project Description: NEW - Construction of a new 2,831 square foot single-family residence with attached 708 sgft garage, including plumbing and mechanical. No decks. ***4 bedrooms/proposed selling price $450,000 BASIC #07-105559 Owner Applicant Contractor Lender NORRIS HOMES INC NORRIS HOMES INC NORRIS HOMES INC BANK OF AMERICA 2053 FABEN DR 2053 FABEN DR NORRIH1099LC ( 5/22/09) 10500 NE STH ST SUITE 400 MERCER ISLAND WA 98040 MERCER ISLAND WA 98040 2053 FABEN DR BELLEVUE WA 98004 Plumbing to be Included?......................................Yes MERCER ISLAND WA 98040 (1 or 2 Census Category: 101- New Single Family House Includes: #1 #2 #3 44 cy Class: T U n T e: Type V- B Type V- B New / Additional Sq. Feet - 1 st Floor....................1285 New / Additional Sq. Feet - 3rd Floor...................0 Occupancy #2 - Area (Sq. Feet).............................708 V - B Basic Plan?........................................................... Yes Occupancy #2 - Construction Type ........................Type V - B New / Additional Sq. Feet - Garage .......................708 R - Number of Bedrooms.............................................4 Occupancy #2 - Class.............................................0 3539 Garage Plumbing to be Included?......................................Yes Occupancy #1 - Use...............................................Residence (1 or 2 family) Zoning Designation ............................................... RS 9.6 New / Additional Sq. Feet - 2nd Floor...................1502 Occupancy #1 - Area (Sq. Feet).............................2831 New / Additional Sq. Feet - Basement...................0 Occupancy #I -Construction Type ........................Type V - B New / Additional Sq. Feet - Deck..........................0 Mechanical to be Included?...................................Yes Occupancy #1 - Class ......... .................................. R - New / Additional Sq. Feet - Other ........................ New / Add' ional Sq. Feet - Total. ............ ..... Occupancy�2 -Use 3539 Garage .......................................Private Mechanical Fixtures Ducts.............................................. 1 Fans................................................ GasLogs ........................................ 1 Ranges............................................ Hot Water Tank ............................. 1 Plumbing Fixtures Bathtubs ......................................... 2 Dishwashers.................................. Lavatories ...................................... 4 Showers.................................. ...... Water Closets ................................. 3 Hose Bibbs.......................... .......... ' c 6 Fu es... ....t ..................... 1 1 Pipe Out ti ............................. 4 1 Laundry Washer Outlets ................ 1 1 Sinks .............................................. 2 2 CONDITIONS: (1). Lots 12 through 19 are required to have the outflow of the dispersal trenches and roof drains installed so that they are directed to the buffer of wetland (Tract A). (2). A two -rail split rail fence shall be installed along the western edge of lots 12 through 19, 21, 23, and 24 to separate the residential lot from the wetland buffer edge, and a metal wetland buffer sign shall be installed on the split r d fence line of lots 12 through 19, 21, 23, and 24 based on the split rail fence and wetland buffet, "I" -et "" aiepicted on sheet 6 ofjW the plat. The entire length of the rail AWe shall be-fully'installed along all affectpr3,rties and inspec>y the city no more than 6 months (1/2) from the date of recording (7/24/08) of the plat or the entire length of the rail fence shall be fully installed along all affected properties before the first residential building permit on lots 12 through 19, 21, 23, or 24 receives final building inspection by the city. The rail fence shall connect to the chain link fencing around the storm drainage pond. PERMIT EXPIRES Tuesday, February 3, 2009 Permit Issued on Thursday, August 7, 2008 I hereby certify that the above information is correct an.1 that the construction on the above described property and the occupancy and the use will be in accordan w' the laws, rules and regulations of the State of Washington an th of Federal Way. Owner or agent: Date: 9-7-08 City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: BRIGHTON PARK LOT 12 Address: 36423 10TH CT SW Permit #: 08 -103551 -00 -SF Includes: #1 #2 #3 #4 Occupancy Class: R-3 u Construction Type: Type V- B Type V- B Occupancy Load: Floor Area (sq. ft.) 1 2,831 1 708 1 0 1 0 Owner Name: NORRIS HOMES INC Owner Address: 2053 FABEN DR MERCER ISLAND WA 98040 Building Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severly affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner / occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. DATE INSPECTOR AREA AND TYPE OF ' S r fi �r THIS CARD IS TO#MAIN ON-SITE t Y CITY OF Community Development Inspection Record Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050 PERMLT #: 08 -103551 -00 -SF Owner: NORRIS HOMES INC Address: 36423 10TH CT SW FEDERAL WAY, WA 98023 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. SWM Precon Site Mtg (4400) ❑ Initial Erosion Control (4365) ❑ Footings/Setback (4110) Approved To be done prior to breaking ground Approved to place concrete By Date By Date G Date ❑ Foundation Wall (4115) ❑ Drainage/Downspout (4040) ❑ Plumbing Groundwork (4190) Approved to place concrete Approved to backfill Approved to cover By Dat S'• v By Date 2 „ .. By Date ❑ Slab/Concrete Floor (4255) ❑ Underfloor Framing (4285) ❑ Floor Sheathing (4105) Approved wplace concrete Approved to sheath floor Approved to install flooring By Date By Date 9�d� By G. Date ❑ Shear Walls (4245) ❑ Roof Sheathing (4220) ❑ Rough Plumbing (4230) Approv to install siding Approved to install roofing Approved By, Date , d� By C Date 0. ej fS ByZ C S Dat.A-% ❑ Mechanical Rough -in (4165) ❑ Gas Piping (4125) ❑ Fire/Draft Stops (4095) Approved Approved to release test Approved By ll t� GAJ Dater. /D By Dated —By G� Date/,( ❑ Interim Erosion Control (4370) NOTE: Prior to scheduling a Framing (4120) ❑ Framing (4120) Approved inspection; Electrical, Plumbing & Mechanical Approved to insulate Rough -in and Fire/Draft Stop inspections must be By 0 ! Date signed -off and approved. IBC 109.3.4/UBC 108.5.4 Date ❑ Insulation (4150)0 Gypsum Wallboard Nailing (4130) ❑ Final Erosion Control (4375) Approved to install wallboard jo Approved to install mud & tape Approved By Date _ B L Date !( `� By Date ❑ Final - Mechanical (4065) Approved Final - Plumbing (4075) 1 JE] Final - Building (4050) Approved I Approved By 1✓ til ) DateZ, j �., (�, By Date? ., t/�� ��1 B i .+.i Date ®` For inspector reference o ❑ Rough Electrical ❑ FINAL - Electrical Approved Approved By Date By Date Federal Waj� E C E I' DPERMIT "43Ly COMMUN17Y DEVELOPMENT SERVICES 33325 81H FEDERAVL WAY, WA 98 63 BOX I L "'APPLICATION 253-835-2607• FAX 253-835-2609 OF FEDERAL WAY Thefoliowing is required infgiq;ation - an incomplete application will not be a< SITE ADDRESS 36423 10th Ct. SW ASSESSOR'S TAX/PARCEL # / ` I OA L- J - O ( -2-- d LEGAL DESCRIPTION (e.g. Acme Estates, Lot i) Brighton Park, Lot 12 (Attach separate page for lengthy legal description) PROJECT• • OF, 1035S/ OMF CO ME EL PL DE EN FP r y / $' / p �r Please print legibly (in ink) or SUITE/UNIT # LOT SIZE (sfl 7868 TYPE OF PERMIT X BUILDING PLUMBING )� MECHANICAL ❑ DEMOLITION ELECTRICAL ❑ ENGINEERING ❑ FIRE PREVENTION SYSTEM PROJECT DESCRIPTION (Provide detailed description of work included on this permit only) Construction of a new 2787 sgft. single family dwelling, with attached 708 sqft. garage, and 44 sgft. covered porch. Built from basic using plan #07-105559-00 SF PROJECT NAME (Name of Business or Owner Last Name) Brighton Park, Lot 12 PEOPLE•• • PROPERTY OWNER CONTRACTOR APPLICANT CONTACT LENDER NAME PRIMARY PHONE Norris Homes Inc. (206 ) 275 -1901 MAILING ADDRESS CITY, STATE, ZIP 2053 Faben Drive I Mercer Island, WA 98040 COMPANY NAME APPLICANT NAME OFFICE PHONE Norris Homes Inc. Norris Homes Inc. James Kerby (206 ) 275 - 1903 MAILING ADDRESS CITY, STATE, ZIP CELL PHONE (206 ) 423 - 4603 2053 Faben Drive Mercer Island, WA 98040 (206 )423 -4603 CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER 2 0- 0 6- 1 0 2 9 0 5- B EXPIRATION DATE L 12 / 31 12008 FAX NUMBER (206 ) 275 - 1910 CONTRACTORS REGISTRATION NUMBER (copy of card required with each application) EXPIRATION DATE N O R R I H 1 0 9 9 L C 05 / 22 /2009 COMPANY NAME APPLICANT NAME OFFICE PHONE Norris Homes Inc. James Kerby (206 ) 275 - 1903 MAILING ADDRESS CITY, STATE, ZIP CELL PHONE 2053 Faben Drive Mercer Island, WA 98040 (206 ) 423 - 4603 RELATIONSHIP TO PROJECT FAX NUMBER ❑ Architect ❑ Tenant Al Agent ❑ Other (Describe) ( 206 ) 275 - 1910 NAME PRIMARY PHONE E-MAIL ADDRESS James Kerby (206 ) 275 - 1903 james(Pnorrishomesinc.com ✓ i9:g196.lindQY''irilnaon is , 'Ar4i'nalu NAME eaceis S,avv N/A MAILING ADDRESS CITY, STATE, ZIP PHONE EXISTING USE ✓ to-,y'T PROPOSED USE Wa-- EXISTING ASSESSED/APPRAISED VALUE $ SPRINKLERED BUIIAING? ❑ YES 4 NO WATER SERVICE PROVIDER kLAKEHAVEN SEWER SERVICE PROVIDER /CLAKEHAVEN VALUE OF PROPOSED WORK $ FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED? ❑ YES NO ❑ STGHLINE ❑ TACOMA ❑ PRIVATE (WELL) ❑ HIGHLINE ❑ PRIVATE (SEPTIC) AREA DESCRIPTION EXISTING SQ. FT. PROPOSED SQ. FT. TOTAL SQ. FT. BASEMENT 0 AIR HANDLING UNITS Ik 1 FIRST REFRIG. SYSTEMS 1285 4' 1285 SECOND HOODS (cocmnerotail 0 1502 1502 THIRD 1 RANGES MISC (Describe) FOURTH 1 FURNACES I GAS WATER HEATERS ADDITIONAL FLOORS (DESCRIBE) PORCH Yes DUCTS 44 44 DECK (COVERED?) PLUMBING GARAGE N CARPORT ❑ 708 '708 NUMBER OF FLOORS s>QertxG MOKOsn 2 roxti 2 1oTAT 7GZt8iMiPra OF TMAi.B OMM6r 9 Md CALeP 333 "NEW HOMES ONLY** NUMBER OF BEDROOMS 4 ESTIMATED SELLING PRICE $ N/A O CI each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. a2AA tM1V1GaG Value of Mechanical Work $ 4200.00 0 AIR HANDLING UNITS 0 EVAPORATIVE COOLERS 1 GAS LOGS 0 REFRIG. SYSTEMS 0 BBQS 6 FANS 0 HOODS (cocmnerotail 0 WOODSTOVES 0 BOILERS 0 FIREPLACE INSERT'S 1 RANGES MISC (Describe) �— COMPRESSORS 1 FURNACES I GAS WATER HEATERS Yes DUCTS 4 GAS PIPE OUTLETS PLUMBING 2 BATHTUBS (or Tb/Shower combo) 1 SHOWERS 3 WATER CLOSETS [i'ottet) MISC (Describe) 1 DISHWASHERS 2 SINKS U— DRINKING FOUNTAINS GAS PIPE OUTLETS 0 SUMPS 0 RAINWATER SYST 1 WASHING MACHINES 0 URINALS 2 HOSE BIBBS 4 LAVS (Bathroom Sinks) 0 VACUUM BREAKERS 0 ELECTRIC WATER HEATERS ')IRC:LAIMER/SIGNATURE BLC I cert(jy under penalty of perjury that the iii{ formation furnished by me is true and correct to the best of my knowledge, and further, that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of F era[ Wag as to any claim (i luding costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which m e made by any person, incl ng the undersigned, and filed against the City of Federal Way, but only where such claim arises out of the reli of the city, including ' cers and employees, upon the accuracy of the information supplied to the city as a part of this application. Permit Coordinator DATE 7.11.2008 NAME/TITLE (Signature) ('fide) RELATIONSHIP TO PROJECT ❑ Owner q Agent ❑ Contractor ❑ Architect ❑ Other Bulletin #100 - January 1, 2006 Page 2 of 4 k\HandoutsWermit Application TRACT 'A" NO 1 020'00"E 58.36' 398' --------------— —I Q1 ' Dispersal Trench per approved 400' construction drawings 130 LF) —� - 402'LO I 404' i M N N 0 O O 6 0 00 00 *7 4" DIA. RIGID ROOF DRAIN TYP. CONNECT TO APPROVED DRAINAGE' YSTEM. O N a PATIO f NANTUC T II �` Co IN FLR. 11 � 5 1285 SOFT I. o m CD I� GA GE I 8 SQFT �— — J 1 DRIVEWAY , CONC.,R 'Al l SkMR S SO 1020'00"W 24.59' I .. 6'-4" STUBBED FROM WATER METER @ CUL-DE-SAC N N / Drainage Calculations Lot area 7868 SQFT Roof Area 2057 SQFT ispersolTrenc Lngh length = 10 I7,p r, so roof area (2O7/ 7001 X 105 17 LF er Impervious SOl SQFT Brighton Park Lot# 12 Sca/e: 1 "=20' ZONING: RS9.6 NOTES Date: 7-11-08 Setbacks 1, 2. 3. Verify garage is inline w/ approach Verify erosion control measures Field check all measurements 36423 10th Ct. SW - Prcl# T.B.D. Front: 20' Drive: 20' Rear. 5' Side Int.: 5' St.: to. Rev: NORRIS 2053 Faben Drive Rhn, Mercer Island, WA 9BU40 Tel 206.275.1901Side v= ® H O M E S norrishamesinc.com Rev: By: Damian Norris 1' PIPE 1' MIN. O.D. MIN. END, CAP OR PLUG I AV,-- �- 7,' CLEAN OUT WYE ' a '• VARIES (TOTAL DISPERSAL TRENCH FROM PIPE (TYP:) '.0— - ` LINEAL FOOTAGE ) FLOW TO SECOND DISPOSAL. 1$1 �X 1$'1 x 18 G • B. % TRENCH OR OTHER BRANCHING _INFLUENT PIPE CB'S AS NECESSARY (TYP) SOLID' r�R /epl-�� (MAX. DESIGN Irl KI FLOW < 0.5 CFS 141 s A PER TRENCH) ! ex LA g - e j/ : e C—_+._-- — INSTALL GRADE BOARD ELEVA11ON PER NOTETYP r`r`/ BELOW PLAN S VE cr n I�I j I cg l ( GRADE TO PROVIDE L' POSITIVE DRAINAGE INSTALL GRADE BOARD FLOW TO OTHER BRANCHING AWAY FROM GRADE ELEVATION PER NOTES CB'S AS NECESSARY I BELOW BOARD. 20% (MAX) I 1' PIPE , 1' Cn � MIN. O.D. MIN. ` NOTE:& GRADE BOARD 24�� ELEVATION , 1. THIS TRENCH SHALL BE CONSTRUCTED SO AS TO PREVENT rr, z LEAN 3/4? -1 1/2° POINT DISCHARGE AND/OR EROSION. I ` �. WASHED ROCK GAL J. °° 2. TRENCHES MAY BE PLACED NO (< 5% FINES) 3 r DOLTS ; . / _ i[ _ CLOSER THAN 50 FEET TO ONE 4 OR 6 PERF. ANOTHER,. INVERT ELEVA11GN1 _ a % e .. :. PIPE LAID FLAT 3. TRENCH AND GRADE BOARD MUST 4 WITH HOLES -DOWN BE LEVEL.: ALIGN TO FOLLOW a d.: 40 MIL PVC CONTOURS OF SITE. `TRENCH BOTTOM LINER 4. GRADE BOARD SUPPORT POST SPACING AS REQUIRED BY SOIL . .2"x12" PRESSURE "' — CONDITIONS. TREATED GRADE 4„x4''-08-40355 1 BOARD SUPPORT POST SECTM A -A 1DISPERSAL TRENCH 1 � (LOTS 12-19) I TOTAL DISPERSAL TRENCH LENGTH i 10 -FT. PER 700 SF OF ROOF AREA. GRADE BOARD ELEVATION SHALL BE SET FOR EACH LOT TO PROVIDE POSITIVE DRAINAGE TO EXISTING DOWNHILL GRADE. TRENCH WIDTH = 3.00 -FT. NOTE: DISPERSAL TRENCHES FOR LOTS 12-19 SHALL BE INSTALLED UNDER EACH APPROVED BUILDING PERMIT, FLOW DISPERSAL TRENCH N.T.S. -- Z RESUBMITTED O NOV 1.0 2008 CITY OF FEDERAL WAY BUILDING DEPT. KNOCKOU'r [{ skies .LB. Dla� lb'x143/r><IA// 6.13. SCID > ),VM -"° 2Q2 -A 'O Ail—Z) 'S'L'N o ff. '� BUSIG old � eooz ti Jnr to�� N 0 , � 3AI;D� 11110d 9NIGIM8 03AO8ddV HOV3 83aNA G311VISNI � — Z,N 38 IIVHS 61-ZI SJ.01 HOd S3HON3d1 IVS83dSia 310N O N —Iz= HIM -.Ip '1j-00'£ 1-10081 o �n 3:+_ i1i 00'L8£ = 31 3d1d ':10d „9 '13-00'£ = HIM HON3di m z3(D Q 05'98£ = WOJ10a H3N3d1 '3aVN9 IIIHNMOO 9NLLSIX3 01 39VNIVda 3ALLISOd 301AOdd 1H .. cr p 09'06£ = NOf1VA313 adV08 30Md9 01101 HOV3 80d 139 38 IIVHS NOLLVA313 08VOO 30Vd9 w v;m ('13 -091'L3 -0Z 111ds) 7d-00'001 = 'V3dV 3008 d0 AS OOL dad 'J3-01 = w �•' w H19N31 HON381 IVSd3dS10 IV101 H19N31 1-1314381 IVSMcIS10 IV101 �rO;