07-100288 City of Federal Way Electrical Permit #: 07-100288-00-EL
Community P.O.velxpment Services FILE
O Box 9718
Federal Way,WA 98063-9718 Inspection Request Line: (253) 835-3050
Ph.(Federal -2607 Fax 063-9718 609
Project Name: NORTHLAKE SHORT PLAT LOT 1
Parcel Number: 618141 0061
Project Address: 32903 42ND AVE S
Project Description: Installation of new 200 amp service,2 t-stats,& 1/v security and data cabling
Owner
Applicant Contractor
QUADRANT CORPORATION,THE QUADRANT CORPORATION,THE MERIDIAN CENTER ELECTRIC INC
PO BOX 130 PO BOX 130 MERIDCE318SG 2/28/07
BELLEVUE WA 98009 BELLEVUE WA 98009 11109 66TH AVE E
PUYALLUP WA 98373
Additional Permit Information
Electrical Fixtures
Low Voltage Burgler Alarm-Resi 1 Service: -Residential
1 Thermostat 2
PERMIT EXPIRES Tuesday, July 31, 2007
Permit Issued on Thursday, February 1, 2007
hereby certify that the above information is correct and that the construction cn the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington
and the City of Federal Way.
Owner or agent: i 1 '— c Date: ,D
•
THIS CARD IS TO REMAIN ON-SITE
CITY OF
Community Development Inspection Record
Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050
PERMIT #: 07-100288-00-EL _
Owner: QUADRANT CORPORATION, THE
Address: 32903 42ND AVE S
FEDERAL WAY, WA 98001
This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD.
Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not
be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence On-going inspections
are logged on the back of this card.
❑ Slab/Concrete Floor(4255) El Ditch cover(4030) -❑ Pool Bonding (4195)
Approved to place concrete Approved Approved
By Date By Date By Date
❑ Temporary Power (4275) ❑ Service (4235) ❑ Feeders/Sub-panels(4045)
Approved Approved Approved
By Date , Byes Date , -Z -J`7 .By Date
❑ Rough Electrical (4225) * ❑ Ceiling Cover(4020) ❑ Final- Electrical(4055)
Approved Approved Approved
By -ec7 Date q- z_07 By Date By A) Date Sal Li a?
•
.❑ Under-slab groundwork(4295)
Approved
1^ F-6-1._.
By a. t„.." Date I-3-r o ,
4 .4...44...4,
Federal Way �r S° PERMIT 0:7 _ o o gel
COMMUNITY DEVELOPMENT 6+, SF MF CO ME PL DE EN FP
33325 FEDERAL ,WA 988 zoo�APPLI CATI O N
FEDERAL WAY,WA 98063-97]8 TD
cis 253-835-2607•FAX 253-835-2609 1
:n4.w.cdnloifede.ar.uCR(cone \
The oliowin• is re•uired i Aan into •lete • ••lication will not be acce•ted. Please •tint le•ib1 in in or y e.
PROPERTY INFORMATION
SITE ADDRESS , Federal Way, WA 98001 32RO� ` 21d7n IoP,`> SUITE/UNIT# N/A
ASSESSOR'S TAX/PARCEL# 6 1 8 1 4 1 - 0 0 6 0 LOT SIZE(sf) 9,631
LEGAL DESCRIPTION (e.g.Acme Estates,Lot 1) Northlake Ridge Short Plat, Lot#1
(Attach separate page for lengthy legal description)
• PROJECT INFORMATION
TYPE OF PERMIT 0 BUILDING D PLUMBING 0 MECHANICAL
El DEMOLITION • ELECTRICAL 0 ENGINEERING 0 FIRE PREVENTION SYSTEM
PROJECT DESCRIPTION (Provide detailed description of work included on this permit onlu)
New single family residence: 200 amp service, 2 thermostats, low-voltage security and data.
PROJECT NAME(Name of Business or Owner Last Name) Northlake Short Plat / 1
• PEOPLE INFORMATION
PROPERTY NAME PRIMARY PHONE
OWNER Quadrant Homes ( 425 ) 455 - 2900
MAILING ADDRESS CITY,STATE,ZIP
PO Box 130 Bellevue,WA 98009
CONTRACTOR COMPANY NAME APPLICANT NAME OFFICE PHONE
Meridian Center Electric Keri Helle ( 253 ) 848 - 5595
MAILING ADDRESS CITY,STATE,ZIP CELL PHONE
11109 66th Avenue East Puyallup,WA 98373 ( )
CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER EXPIRATION DATE FAX NUMBER
0 2 - 0 0- 1 0 2 1 6 2 - B L 12 / 31 / 2007 ( 253 ) 841 - 0892
CONTRACTOR'S REGISTRATION NUMBER loopy of card required With each application) EXPIRATION DATE
M E R I D C E 3 1 8 S G 02 / 28 / 2007
APPLICANT COMPANY NAME APPLICANT NAME OFFICE PHONE
Quadrant Homes Quadrant Homes ( 425 ) 455 - 2900
MAILING ADDRESS CITY,STATE,ZIP CELL PHONE
PO Box 130 Bellevue,WA 98009 (425 ) 864 - 0976
RELATIONSHIP TO PROJECT FAX NUMBER
0 Architect 0 Tenant •Agent 0 Other(Describe) (425 ) 452 - 6535
CONTACT NAME PRIMARY PHONE E-MAIL ADDRESS
Glen M. Lyons ( 425) 646 - 8360 glen.lyons @quadranthomes.com
LENDER Per RCW 19:27095: Lender information is NAME
required if project value exeeeds$5,000
MAILING ADDRESS CITY,STATE,ZIP
DETAILED BUILDING INFORMATION
EXISTING USE N/A PROPOSED USE Single Family Residence
EXISTING ASSESSED/APPRAISED VALUE $ N/A VALUE OF PROPOSED WORK $ 120.583.00
SPRINKLERED BUILDING? 0 YES • NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED? 0 YES • NO
WATER SERVICE PROVIDER • LAKEHAVEN 0 HIGHLINE 0 TACOMA 0 PRIVATE(WELL)
SEWER SERVICE PROVIDER • LAKEHAVEN 0 HIGHLINE 0 PRIVATE(SEPTIC)
3�! '- 7 i
LI
PROJECT FLOOR AREAS
AREA DESCRIPTION EXISTING PROPOSED TOTAL
SQ.FT. SQ.FT. SQ.FT.
BASEMENT
O 0 0
FIRST
O 1,463 1,463
SECOND
O 1,796 1,796
THIRD
o 0 0
FOURTH
O 0 0
ADDITIONAL FLOORS (DESCRIBE)
O 0 0
DECK(COVERED?)
O 152 152
GARAGE ® CARPORT❑
o 400 400
EXSTIRO PROPOSED TOTAL . 'TOTAL-10 0TME°sr TOM ProPOSBtm 'ISOICi45°
NUMBER OF FLOORS 0 2 2 0 .;,3,811 ABU
**NEW HOMES ONLY** NUMBER OF BEDROOMS ESTIMATED SELLING PRICE $ 424,970.00
FIXTURES
Indicate number of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain.
MECHANICAL
Value of Mechanical Work $
AIR HANDLING UNITS EVAPORATIVE COOLERS _ GAS LOGS REFRIG.SYSTEMS
BBQS FANS HOODS(Commerclaq WOODSTOVES
BOILERS FIREPLACE INSERTS RANGES MISC(Describe)
COMPRESSORS FURNACES GAS WATER HEATERS
DUCTS GAS PIPE OUTLETS
PLUMBING
BATHTUBS(or-rub/show,Combo) SHOWERS WATER CLOSETS trouet) MISC(Describe)
DISHWASHERS SINKS DRINKING FOUNTAINS
GAS PIPE OUTLETS SUMPS RAINWATER SYST
WASHING MACHINES URINALS HOSE BIBBS
LAYS(Bathroom slnk,1 _ VACUUM BREAKERS ELECTRIC WATER HEATERS
DISCLAIMER/SIGNATURE BLOCK
I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I
am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold
harmless the City of Federal Way as to any claim(including costs, expenses, and attorneys'fees incurred in the investigation and defense of
such claim),which may be made by any person,including the undersigned,and filed against the City of Federal Way,but only where such claim
arises out of the reliance of the city, chiding its officers and employees,upon the accuracy of the information supplied to the city as a part of
this application. I
NAME/TITLE Alt Glen Lyons.Asst.Print.Oos.Mar..Quadrant Homes DATE 1/16/2007
er (Si 're) (Title)
RELATIONSHIP PROJ ❑ Owner • Agent ❑ Contractor ❑ Architect ❑ Other
FOR O It US ONLY ri
o NEW a ADDITION o ALTERATION I LICENSED AS PROVIDED 8Y LAW AS
BUILDING SHELL ONLY? o YES o NO
ELEC CON2'R GENERAL 3 a NO
ZONING DESIGNATION LICENSE # EXP. DATE _ a NO
EC01 MERTDCE318SG 02/28/200? 3: oNO '
NEW ADDRESS REQUIRED? o YES ❑NO EFFECTIVE DATE 01/07/1964
PLATTED LOT? o YES a NO 3 'a NO
MERIDIAN' CENTER ELECTRIC INC
11109 66TH AVE EAST
PUYALLUP WA 98373
Signature ._,._, _
Issued by DEPARTMENT OF LABOR AND INIWSTRIES
Bulletin#100—August 19,2004 Page 5 of 4 k\Handouts\Permit Application
•
ELECTRICAL PERMIT INFORMATION
1.---- RESIDENTIAL COMMERCIAL
NEW RESIDENTIAL SERVICE NEW COMMERCIAL/INDUSTFUAL SERVICE
.,Single Family Square Feet. The Service or Feeder Rath Add'n
(First 1300 IV-$101.50;Each addh 6110 Al:$33.501 ❑ 0 to 100 amp $113.50 $69.50
❑ Detached outbuilding or garage ❑ 101 -200 amp 141.00 89.00
(Inspected with service) $44.00 ❑ 201-400 amp 264.50 104.00
❑ Detached outbuilding or garage ❑ 401-600 amp 308.00 123.50
(Inspected separately) $69.50 ❑ 601-800 amp 398.50 . 168.50
❑ 801- 1000 amp 486.50 203.50
NEW MULTI-FAMILY(three units or more) ❑ Over 1000 amp 530.50 283.00
Service Feeder
❑ Up to 200 amp $113.50 $33.50 ❑ Over 600 volts surcharge $89.00
❑ 201 -400 amp 141.00 69.50 ❑ Mast or meter repair $96.00
❑ 401 -600 amp I93,00 96.00
❑ 601 -800 amp 247.00 132.00 ALTERED COMMERCIAL/INDUSTRIAL
❑ Over 800 amp 353.50 264.50 Service or Feeders
❑ 0 to 200 amp $113.50
ALTERED SINGLE/MULTI$AMILY Cl 201 -600 amp 264.50
Service or Feeder 0 60 -1000 amp 398.50
CI to 200 amp $87.00 ❑ over 1000 amp 443.50
U 201 -600 amp 141.00 ❑ X of circuits to be added/altered
❑ over 600 amp 212.50 (1-5 circuits-$89.00;Addh circuits.$7.00/eat
❑ a of circuits to be added/altered COMMERCIAL/INDUSTRIAL PLAN REVIEW
(1-4 circuits469-50;Add'n circuits$7.00/ea) $89.00 plus 35%of Permit Fee
❑ Service- 1,000 amps or greater
❑ Mast or meter repair $52.00 ❑ Medical/Educational/Institutional Facility
MOBILE IiOMES
❑ Service or feeder only $69.50
❑ Service and feeder $113.50
TEMPORARY SERVICE
MOBILE HOME/RV PARK ResidentiaVMulti-Patmt/y $61.00
❑ #of service or feeders
(First.e vice/reedei-$69-50;each addh 445.00) CommercfaVIndustriat Service or FeederAmpactty
Cl 0-100 amps ._ $69.50
❑ I01-200 amps 89.00
❑ 201 -400 amps 104.50
❑ 401 -600 amps 141.00
❑ over 600 amps 152.50
MISCELLANEOUS SERVICE/EQUIPMENT
® 2 #of Thermostats Ci I of Signs
(First 452.00;addh-$16.00/ca) (First sign-$52.00;addh
sign 524.50/ea)
e Low Voltage The ❑ Swimming pool/hot tub $87.00
Square Feet to be served by system(s) Fnrmt,la (Includes additional circuit,if required)
■ Fire Atarm System Cl Yard Pole meter loops $104.50
r Security Alarm system ❑ Additional Plan Review $104.50/hour
• voice Cabling (for modified submittals)
• Data Cabling
❑ ❑ Automation Fee on all Permits .. $5.00
(Per Syste,n(a) to 2500(t2461.00;
Each add'n 2500 tt2-t6.00) 'Per WAC 2464$.9/0(5)(244 k el
Bulletin#100-January 7.2005 Page 3 of 4 killandoutsTermitApplication _