Loading...
07-101467 City of Federal Way Electrical Permit #: 07-101467-00-EL Community Development Services P.O.Box 9718 Federal Way,WA 98063-9718 Ph:(253)835-2607 Fax:(253)835-2609 Inspection Request Line: (253) 835-3050 Project Name: CAPITAL SQUARE Project Address: 700 S 320TH ST Parcel Number: 082104 9265 Project Description: Install a new 200amp house panel and misc wiring to house panel. Relocate existing circuits from existing panels to other existing panels. Owner Applicant Contractor CAPITAL SQUARE ASSOCIATES NORTH STAR ELECTRIC NORTH STAR ELECTRIC 31919-1ST AVE S 1905 S JACKSON ST NORTHSE136O8 9/28/07 SEATTLE WA 98144 1905 S JACKSON ST FEDERAL WAY WA 98003 SEATTLE WA 98144 Additional Permit Information Electrical Fixtures Alt. Serv./Feeder up to 200 amps- 1 Circuits- Commercial 12 PERMIT EXPIRES Sunday, September 16, 2007 Permit Issued on Tuesday, March 20, 2007 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington ( an the City of Federal Way. Owner or agent: " 1` ��– Date: ,� — ' . ` - , ' THIS CARD IS TO REMAIN ON-SITE CITY OF - -z:El,— Community Development Inspection Record Federal Way IVR INSPECTION REQUEST PHONE # (253) 835-3050 PERMIT #: 07-101467-00-EL Owner: CAPITAL SQUARE ASSOCIATES Address: 700 S 320TH ST FEDERAL WAY, WA 98003-5267 This card is part of your required inspection documents. Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence On-going inspections are logged on the back of this card. ❑ Slab/Concrete Floor(4255) ❑ Ditch cover(4030) ❑ Pool Bonding (4195) Approved to place concrete Approved Approved By Date By Date By Date ❑ Temporary Power (4275) ❑ Service(4235) ❑ Feeders/Sub-panels (4045) Approved Approved Approved By Date By - v. Date 3-„2 i—D By Date ❑ Rough Electrical (4225) ❑ Ceiling Cover(4020) ❑ Final-Electrical(4055) Approved Approved Approved By Date By Date ,By ` Date S- 61-6 7 ❑ Under-slab groundwork(4295) Approved By Date Building Division C1tY OF 33325 Ei ghth Avenue South Federal Way IDO Box 9918 Federal Way 98063-9718 Phone 253-835-2607 Fax 253-835-2609 INSPECTION NOTICE ADDRESS: `1 a O $ o #: ©` 1-1 e 1 4 �� N E c R-1\ Gw c_^\\iD > > 1 � l/ {/\ r IF YOU HAVE ANY QUESTIONS CALL (253) 835- , Call for reinspection before cover WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE-INSPECTION. SEE BACK OF CARD FOR DETAILS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of RECEIVED Of 4044'4 Federal Way MAR 2 p 2007 PERMIT SF MF CO ME®PL DE EN FP COMMUNITY DEVELOPMENT SERVICES 33325 8^'AVENUE SOUrfi•PO BO1j��Zj@�FEDERAL WAY,WA 98063-9768 F I Y OF FEDEpLI CATI O _-- - -- /----_ 253-835-2607•FAX 253-835-2609 BUILDING www.cituoRederNwou.Com The following is required information-an incomplete application will not be accepted. Please print legibly(In ink)or type. • PROPERTY INFORMATION SITE ADDRESS 700 r _3 a S . SUITE/UNIT x ASSESSOR'S TAX/PARCEL it C) C I 1 (_ '4 - Cl Z L S LOT SIZE(s) LEGAL DESCRIPTION(e.g.Acme Estates,Lot 1) (Attach separate page for kngthy Iegat descrlpooN • PROJECT INFORMATION TYPE OF PERMIT 0 BUILDING 0 PLUMBING 0 MECHANICAL 0 DEMOLITION.ELECTRICAL 0 ENGINEERING 0 FIRE PREVENTION SYSTEM PROJECT DESCRIPTION(Provide detailed description of work included on this permit only) 0 s ALL / L4) AI) Ps 401.1>.E pih.t.er-, s t k l'A rim g�,� ' Q� Oc�-+ b✓`f'e c_i ii y a . e 64.4e o ...c S' o a ✓SE Kb . £ Ci/LCJ 41 , /0 /A /I b . • -" #. _ 0- • ` *t YA 0 - ` , . r / # A-5- . . `► C i/.0 IJ.'f) T'.ta.�' O ✓:Ce 4 it gkeee- (/ r 9 ) PROJECT NAME(Name of Business or Owner Last Name) CC 1)p r t A^ - '''' 04/M_ f 11,e- • PEOPLE INFORMATION PRIMARY PHONE PROPERTY NAME ►� y� 1 ►[ ) OWNER C r r I�n^ � � "� ING ADD CRY.STATE,ZIP E-MAIL ADDRESS �o t 610?( 11) 9/ S u / '791/8 r CO APPLICANT NAME OFFICE PHONE CONTRACTOR a yZ (�b(o13 `� -l57to /l S K sec ;c rYt C x: MAILING ADDRESS l CITY,JS- ZIP I t,.� /C�/EL��L PHONE z J905- �. Ti4 -Aj Vt4 S�' 7�l Cfi,4. '/ / Y VO4,)FAXNUMI, ! / / CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER 9 t7--'(/d—) 0/erg `00 AL 1IONDA7E 57 COn e� CONTRACTOR'S REGISTRATION NUMBER ° ° .°° �' /1104445 a6 oe 9 ,,/cli� COMPANY NAME APPLICANT NAME OFFICE PHONE APPLICANT ( l - MAILING ADDRESS CITY,STATE.ZIP CELL PHONE I I l RELATIONSHIP TO PROJECT FAX NUMBER 0 Architect 0 Tenant 0 Agent 0 Other ( ) PROJECT PRIMARY PHONE E-MAIL ADDRESS CONTACT N ; rC , cod?D.E ,a6)/5-s-- 91/,— .717a,/c_•DNStA/e.,k,CoWN LENDER NAME Per RCW 19.27.095: Lender information is required if project value exceeds$5.000 MAILING ADDRESS CITY.STATE,ZIP PHONE I l NI DETAILED BUILDING INFORMATION EXISTING USE PROPOSED USE EXISTING ASSESSED/APPRAISED VALUE $ VALUE OF PROPOSED WORK $ SPRINKLERED BUILDING? 0 YES 0 NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED? 0 YES 0 NO WATER SERVICE PROVIDER 0 LAKEHAVEN 0 HIGHLINE 0 TACOMA 0 PRIVATE(WELL) . SEWER SERVICE PROVIDER 0 LAKEHAVEN 0 HIGH INE ❑ PRIVATE(SEPTIC) • PROJECT FLOOR AREAS AREA DESCRIPTION EXISTING PROPOSED TOTAL SQ.FT. SQ.FT. SQ.FT. BASEMENT • FIRST SECOND THIRD ADDITIONAL FLOORS(DESCRIBE) DECK(0 COVERED OR ❑UNCOVERED?) GARAGE ❑ CARPORT ❑ run= PROPOSED TOTAL TOTAL SORTav SF TOTAL PROPOSED SF TOTAL SF NUMBER OF FLOORS "NEW HOMES ONLY NUMBER OF BEDROOMS ESTIMATED SELLING PRICE $ IN FIXTURES Indicate number of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. MECHANICAL Vohip of Mechanical Work $ (A COPY OF BID OR ESTIMATE MUST BE INCLUDED WITH APPLICATION) AIR HANDLING UNITS EVAPORATIVE COOLERS GAS PIPE OUTLETS WOODSTOVES BBQS FANS GAS WATER HEATERS MISC(Describe) BOILERS FIREPLACE INSERTS HOODS(COmmticla() COMPRESSORS FURNACES RANGES DUCTS GAS LOG SETS REFRIG.SYSTEMS PLUMBING BATHTUBS(or Tub/Shower COmbol IAVS(Balh.aom Sinks) URINALS MISC(Describe) DISHWASHERS RAINWATER SYST VACUUM BREAKERS DRINKING FOUNTAINS SHOWERS WATER CLOSETS tlbueu ELECTRIC WATER HEATERS SINKS WASHING MACHINES HOSE BIBBS SUMPS SIGNATURE I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further, that I am authorised by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of Federal Wag as to any claim(including costs, expenses, and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the City of Federal Way,but only where such claim arises out of the reliance of the city,including its officers and employees,upon the accuracy of the information supplied to the city as a part of this application. ,Q�/ /J,� 1 NAME/TITLE i O.c &9614-4)L-13 .4)1-1J4 1 )4& DATE Q�0—oT (Signature) fltlel RELATION PROJECT ❑ Owner ❑Agent tractor n Architect ❑ Other FOR OFFICE USE ONLY c NEW ❑ADDITION c ALTERATION o REPAIR ❑TENANT IMPROVEMENT BUILDING SHELL ONLY? c YES c NO BASIC PLAN? c YES ❑NO ZONING DESIGNATION CHANGE OF USE? ❑YES c NO NEW ADDRESS REQUIRED? o YES ❑NO UP/SEPA/SU? ❑YES c NO PLATTED LOT? c YES o NO DEMO PERMIT REQUIRED? ❑YES c NO Bulletin#100–January 1,2007 Page 2 of 4 k\Handouts\Permit Application ELECTRICAL PERMIT INFORMATION RESIDENTIAL COMMERCIAL NEW RESIDENTIAL SERVICE NEW COMMERCIAL/INDUSTRIAL SERVICE Service or Feeder Each Add'n ❑ Single Family Square Feet (First 1300 IV-$111.00;Each add'n 500 ft2-$35.50) to 100 amp $120.50 $74.00 ❑ Detached outbuilding or garage 01-200 amp 149.50 94.50 (Inspected with service) $47.00 ❑ 201 -400 amp 280.00 111.00 ❑ Detached outbuilding or garage ❑ 401-600 amp 327.00 131.00 (Inspected separately) $74.00 ❑ 601-800 amp 423.00 179.00 ❑ 801 - 1000 amp 516.50 216.00 NEW MULTI-FAMILY(three units or more) ❑ Over 1000 amp 563.00 300.00 Service Feeder ❑ Up to 200 amp $120.50 $35.50 ❑ Over 600 volts surcharge $94.50 ❑ 201 -400 amp 149.50 74.00 ❑ Mast or meter repair $102.00 ❑ 401 -600 amp 205.00 102.00 ALTERED COMMERCIAL/INDUSTRIAL ❑ 601 -800 amp 262.00 140.50 ❑ Over 800 amp 375.50 280.50 Service or Feeders s0 to 200 amp $120.50 ALTERED SINGLE/MULTI FAMILY ❑ 201 -600 amp 280.50 ❑ 601 - 1000 amp 423.00 Service or Feeder ❑ over 1000 amp 471.00 ❑ 0 to 200 amp $92.50 ❑ 201 -600 amp 149.50 J7� I -#of circuits to be added/altered ❑ over 600 amp 225.50 \ (1-5 circuits-$94.50;Add'n circuits,$7.00/ea) ❑ #of circuits to be added/altered COMMERCIAL/INDUSTRIAL PLAN REVIEW (1-4 circuits-$74.00;Add'n circuits$7.00/ea) $94.50 plus 35%of Permit Fee ❑ Service- 1,000 amps or greater ❑ Mast or meter repair $55.00 ❑ Medical/Educational/Institutional Facility MANUFACTURED HOMES ❑ Service or feeder only $74.00 ❑ Service and feeder $120.50 TEMPORARY SERVICE MOBILE HOME/RV PARK Residential/Multi-Family $65.00 ❑ #of service or feeders (First service/feeder-$74.00;each add'n-$48.00) Commercial/Industrial Service or Feeder Ampacity ❑ 0- 100 amps $74.00 ❑ 101-200 amps 94.50 ❑ 201-400 amps 111.00 ❑ 401-600 amps 149.50 ❑ over 600 amps 162.00 MISCELLANEOUS SERVICE/EQUIPMENT ❑ #of Thermostats ❑ It of Signs (First-$55.00;add'n-$17.00/ea) (First sign-$55.00;add'n sign$26.00/ea) ❑ Low Voltage ❑ Swimming pool/hot tub $111.00 Square Feet to be served by system(s) (Includes additional circuit,if required) ❑ Fire Alarm System ❑ Yard Pole meter loops $74.00 ❑ Security Alarm System ❑ Additional Plan Review $111.00/hour ❑ Voice Cabling (for modified submittals) ❑ Data Cabling ❑ Automation Fee on all Permits .. $5.00 0 Pi 2500 ft2-$65.00; Each add'n 2500 fti-17.00)•Per WAC 296-46-91 on)@Ii&W Bulletin#100-January 1,2007 Page 3 of 4 k\Handouts\Permit Application