McBride Const. Resources Inc. October 23, 2009
Attn: Charles Sharpe
224 Nickerson Street
Seattle, WA 98109
RE: File#09-103987-00-SH;SECHRIST
32817 38th Avenue South, Federal Way
Dear Mr. Sharpe:
This letter responds to your request for a shoreline exemption for a replacement of an existing CMU
retaining wall that abuts the south side of the residence at 32817 38th Avenue South, on North Lake. The
CMU retaining wall to be replaced has been damaged by a recent water main break near the residence.
You have also requested a determination as to whether this activity is exempt from State Environmental
Policy Act(SEPA)review.
Shoreline Substantial Development Permit Exemption
Washington Administrative Code(WAC) 173-27-040 identifies actions exempt from the requirement to
obtain a shoreline substantial development permit. WAC 173-27-040(2)(b)exempts, "normal maintenance
and repair." Subsection 040(b)(2)goes on to state that normal maintenance and repair means to restore a
development to a state comparable to its original condition, including but not limited to its size, shape,
configuration, location, and external appearance, within a reasonable period after decay or partial
destruction, except where repair causes substantial adverse effects to shoreline resource or environment.
There is no evidence that this activity will result in substantial adverse impacts to shoreline resources or
environments. Therefore, the replacement of the CMU retaining wall is considered an exempt action and
does not require a shoreline substantial development permit.
State Environmental Policy Act Exemption
WAC 173-11-800 identifies actions that are exempt from SEPA review. Subsection 3 exempts repair,
remodeling, and maintenance under specific circumstances. Repair,remodeling, maintenance, and minor
alteration is considered exempt, except on lands covered by waters, in which case only minor repair or
replacement is exempt. Given that the work involves replacement of an existing CMU retaining wall that
is not covered by water, it meets the definition of minor repair. Therefore, the proposed work is exempt
from SEPA review.
Work cannot commence on this project until building permit#09-103986-00-SF has been issued.
Please keep a copy of this letter on site during construction. Please contact me if you have any questions.
I can be reached at 253-835-2622 or david.lee@cityoffederalway.com.
Sincerely,
avid Lee
Associate Planner
c: Fernando Fernandez,Plans Examiner
Doc.I .51928
9t 44 OG����l 3<<�`��C` / McBride s incorporated
(/ �l '" Resources Incorporated
224 Nickerson Street
Seattle,Washington
98109-1622
Telephone
RECEIVED 2 ) 8
7121( 06 6e
(206)284-5670
October 12, 2009 OCT 1 2 2009
Janet Shull CITY OF FEDERAL WAY I I
Senior Planner CDS
City of Federal Way McBRIDE
Department of Community Development
Re: Substantial Shoreline Permit exemption request for flood damage mitigation for
Sechrist residence at 32817 38th Avenue S
Dear Janet,
McBride Construction Resources Inc. will be applying for a building permit to do repairs
to the above referenced house.
This letter is to request an exemption from a substantial shoreline development permit for
repairs to the Sechrist residence due to a recent water main break at the street just above
their house. The house is located on the east shore of North Lake. The water from the
broken main washed some soil away from the south side of the residence, structurally
compromising an existing CMU retaining wall. Repairs involve temporarily shoring the
south elevation of the house and replacing the damaged wall to the same configuration.
Due to the fact that the house is structurally compromised and the fact that the rainy
season is fast approaching, we are requesting an expedited review of this project as well
as an expedited review of the shoreline exemption request.
We plan to take reasonable measures to keep silt out of lake. These measures include
placing a silt fence across the site below our work as well as a straw wattle. We will also
be covering any stockpiled dirt on site with plastic sheeting. The restoration landscaping
is not part of this permit request so we will leave the disturbed area covered with straw r
until the landscapers are able to complete the restoration.
Fernando Fernandez has already promised an expedited review of the building •'
component of our application for permit. If you have any questions, please don't hesitate
to call. Thank you,
•
Charley :h.
roduction Superintendent
McBride Construction Resources Inc.
•
224 Nickerson •
Seattle WA 98109
206-283-7121
chas @mcbridecontruction.com
•
Insurance repairs'
and all phases
of commercial and
residential construction
#MCBRICRO99JZ
I, • •
44
EXT FACE CLR COVER PER
' 1 ( WALL SECTIONS, TYP
---1 N I
CONC RETAINING WALL PER
,° a a PLAN & WALL SECTIONS
.
'ai '• ___IT d. °d
° ° Ili.
PLAN 1. a ° ° a — VERT REINF PER
FIN GRADE ° — WALL SECTIONS, TYP
i' e e it I
-1 11= ° ° °— HORIZ REINF PER
fD 1-1 I I ;. 44 a e •° 'I I WALL SECTIONS &
III I °" .° I—I I PLAN BELOW, TYP
4 .d °
CONTROL(
JOINT SECTION
_ _ CLR COVER PER
WALL SECTIONS
WHEN VERT REINF IS
,.` ° a 1 a DIRECTLY BEHIND CONTROL
G� d . JOINT, ADJUST AS SHOWN
1 1
>c.-.N i 1 (
° d
NOTE: ° `
O I
VERTICAL CONTROL JOINTS TO 3'4 d ,
BE LOCATED PER ARCHITECTURAL 2 ! ALTERNATE HORIZ REINF TO
OR 10'--0"OC MAXIMUM. PLAN BE DISCONTINUOUS AT EA
CONTROL JT
VERTICAL CONTROL JOINT
AT CONCRETE RETAINING WALLS
02310 SCALE: NONE
®Co prig ht 14/2069 Amok Converse=Ltc All Rights Reserved n:.°.e,....t,.....st...me d.dgw�,rot w e.a4
M.h4•or b pmt,Wheat.dd.permeate.tree.D'MN.C.i.r.or.r.Oasts CO..111040 YK d.ddm.ey(momTl*to.M.ufw@xhr!u... •
PROJECT NAME: ' JOH'ar
3287 38th Ave S. G� of WAY Gf
PROJECT No: SKETCH N0 �� '' 4
09-11-0286 SSK-2 ��, ;A 4 '0 9
snGi eeRse 'j
10900 NE FOURTH ST•SUITE 1200 DATE: p CONSTRUCTION FIELD SKETCH:
„r,.
BELLEWE,WASHINGTON 98004 10109109-2:57 m STRUCTURAL 4
PHONE(425)827-2238• FAX:(425)827-8988 BY: RETAINING WALL •ip, I�090�#0' . '
WEBSITE: www.dci-engineers.com RC AI,s'O' 1*'
1VIL / aTF?L.ICTt 11�AL sfONAL �'"�
09286-SSK2,dwg 09 Oct 2009 - 2:57 pm rcornohan
0 ' -, .'' - 4, 4... 4.._
C/A
sr se sr
a 7"'a o
0 11 �0 19 LIS,tie g,�4O`V•
J Z q" Q
sr et 'd-
i"- p] C)
Cri
O O
CI 0 z n
Z OW ___ v
W �'
Z o ° Taw
U L'- 0 O O CA NU ? =
CO d O c P
0 ® ® ® M � ¢
W
Z
Zd s� N L
r'
O .__I U U U
O O O Q ti _°s vi
I N N
Q
Z W g
O f0 7"' m
U. U E ® 0 0 J �_ e Q Cc CD E
;.I
O = Dg � c� cc
J w o 0 0 :_ I_ iii W ao W a o
< cc U N N V' 1 i M a fc S 8
Q ® ® ® z
to �n �n w t� k.-VI c' �, J t
Z V) ca (0 co I--Z�-°
MEM N w a �O� gI-
Z J O Z ` IiOPJh W » ° o
g$ WAN #
R Z >�uj -� _v.
J W O O 2,:z
I s "7 O J w P ' x
ce Li_
d I t I 1!.
o
r O a
1:0*
= 1 I I
-CO
fl. I I
(.- 1J
NI' a (fl
J
1 Q w JW Q
~o
CD C3
W z I-�-
� - ¢ C�
. w
Y z
FL z� o z � o t- � oz J
al c: w� w ¢Lt Z LI- O Oc, cd:
Vi m Np �r� O✓ Q �p 0 O � "---- 0
x .Q fY W �.Y L.� CD W = W
w W LL a-d
Lu
1- \
,k c ° c� >= a ON 31 Qw m°w" coo =
1/4.'''•..... \ H
11it §aw.. g ° L� 810 „z �� � � 47: 33 Cl)
isra r i ° Q
„91 I
1r�l+ ��+ �lr �l+ r,
- r�N1►"i'+li'+ll444''� Z
.i !lrwoolk!Jti . `'-lb,1,..,1 :11-40%.Yl4 W J
WitotebyttApt
y� a m>''e ci vi; 3�.1i�oMNr7YerAra a °
a.U • v 9 � ' ti I" 4'1.0 ..- � CO
Z
I 1=-1
z 1 ° a
;.__._...._ 11—I w
� N ��� 2110 s o
CC
o MN „g � I1 >< Q
, ig V
,__
11=1 Cr
>� —1I1 ° • w
o.„b i I.-.gig ii W i
.< CD ""' i It) <X r93
r- r 9�' ` R e113 ,� 3 V o
H { .: 1'__. ] ••£
Ai p .7
$ .� NIW „9-,L 4.1.)
r
s
ViiIi.�.,�
Iiiiii3Nn �U213dOdd 40.0E was ....■--7. 1=M 71117. 1■D IIIMM MMIIMMENNIF 404."Ilk,
I-
1w
141
'Or ."1417...Z. Axt, 77-/ -4.7,--z-::: g
--1- w
• I Ilk& > N g Ili 0 U� 1 tW Li-
► ,�'' L1J I___
o z w oC 1 /
1 , o
1
N I
X
/ Q '
SIt--T — —
4110 ' i`(1%I I
--71,ir I OR
/ • ,
1 ,oz dr ,.
I —,
I
ejin
I,,, Z I
kj
c=.10 I-- W �I
_Z
J
WI r
Z
a ,S 1 ce
a
o lo
N - N
Co '4I
Itka,► I
=ITr - - _ _ /f, _ 1\
Oil -- I I / IIIPIO.V. \
I I 1 >\►1
L 1 — �—
1 , I
�r
• i I , II i
coil ______ I I I
— _
[01
W
in
1 0 q.
c
of til
0017 ---'--.ifalr: .r< 0 n
• 3NIl J.12! 0 i7
tN Li
�
O
1
2