15-103419 fes_ .._.
Electrical
LcommCity Federal y
I
uni &EcnDev.Services Permit #: 15-103419-00-EL
33325 8th Ave S
Federal Way,WA 98003 Inspection Request Line: 253 835-3050
Ph:(253)835-2607 Fax:(253)835-2609 p q
Project Name: WSECU
Project Address: 34024 HOYT RD SW Unit G Parcel Number: 308900 0320
Project Description: Demo 200A panel and feeder.Relocate 200A panel and feeder.Provide new LED light
fixtures.Provide new lighting controls and plugs.Provide new floor boxes.
Owner Applicant Contractor
TOO HOYTIE TOYTIE LLC ANDY BURKE TITAN ELECTRIC
416 101ST AVE SE TITAN ELECTRIC TITANEI963OB(9/2/16)
BELLEVUE WA 98004 12828 NORTHUP WAY SUITE 205 12828 NORTHUP WAY SUITE 205
BELLEVUE WA 98005 BELLEVUE WA 98005
Additional Permit Information
Is this an Online or O.T.C.application? Yes Is Use Educational or Institutional? No
Service greater than 999 Amps? No
Electrical Fixtures
Alt.Srvc/Feeder 0 to 200 amps(C 2 Circuits-Commercial 51 Sign 2
PERMIT EXPIRES Sunday, January 24, 2016
Permit Issued on Tuesday, July 28, 2015
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington
and the City of Federal Way.
Owner or agent: Date:ate:
DATE INSPECTOR AREA AND T'A'PE O \SPECTION
q 11%11T w43 P4141G1 P-a.11. - ot.. Ta awe. 146i-r,./ivv W6IIs < CA-4-s.
,
exeAvdoc Rok51.-11, Ge er.di (414(1 r 5oScj c.4t.s .
��'�" Construction Intection Record
Federal Way INSPECTION REQUTS: (253)835-3050
PERMIT#: 15-103419-00-EL Address: 34024 HOYT RD SW Unit G
Project: TOO HOYTIE TOYTIE LLC FEDERAL WAY, WA 98023
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
0 UFER Ground (4295) 0 Ditch cover(4030) 0 Slab/Concrete Floor(4255)
Approved Approved Approved to place concrete
By Date By , Date et—1u\—t 5 By Date
[0_ Pool Bonding(4195) 0 Temporary Power(4275) 0 Service(4235)
Approved Approved Approved
By Date By Date By Date
El Feeders/Sub-panels(4045) ❑ Rough Electrical(4225) 0 Ceiling Cover(4020)
Approved Approved Approved
By Date .01 ,1 By c Date _�l,l �, By Date t t (1 I I S
'LT—final-Electrical(4055)
Approved
By ,,` Date \ 0 -2.1.-\S,
Rough Electrical
ElFinai Electrical
IDRight of Way
Approved Approved Approved
By Date By Date By Date