12-102789 ' • ,n Elecrtrical t. Ci &FederalWay Permit #: 12-102789-00-E L CommunityEcon.n.Dev.Services 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 w ori:? Project Name: KROPP Project Address: 29838 MARINE VIEW DR SW Parcel Number: 515320 0130 Project Description: Install solar photovoltaic system Owner Applicant Contractor WALTER P KROPP ADAM LEE PUGET SOUND SOLAR LLC 29838 MARINE VIEW DR SW PUGET SOUND SOLAR LLC PUGETSS920RH(12/8/12) FEDERAL WAY WA 98023-3422 5308 BAKER AVE NW 5308 BAKER AVE NW SEATTLE WA 98107 SEATTLE WA 98107 Additional Permit Information Is Use Educational or Institutional? No Service greater than 999 Amps? No Electrical Fixtures Alt.Serv./Feeder:0 to 200 amps(F 1 PERMIT EXPIRES Sunday, December 16, 2012 Permit Issued on Tuesday, July 10, 2012 I hereby certify that the above in • ma'.n is correct and that the construction on the above described property and the occupancy and the use ' be i' -ccordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: 7//6)/(2 l . 44414'4V /e3/i2.. THIS CARD IS TO MAIN ON-SITE CITY of Construction In ection Record — Federal Way INSPECTION REQU TS: (253)835-3050 PERMIT#: 12-102789-00-EL Address: 29838 MARINE VIEW DR SW Project: WALTER P KROPP FEDERAL WAY, WA 98023-3422 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. ❑ LIFER Ground(4295) ❑ Ditch cover(4030) El Slab/Concrete Floor(4255) Approved Approved Approved to place concrete By Date By Date By Date 0 Pool Bonding(4195) ❑ Temporary Power(4275) 0 Service(4235) Approved Approved Approved By Date By Date By Date 0 Feeders/Sub-panels(4045) • 'El Rough Electrical(4225) ❑ Ceiling Cover(4020) Approved Approved Approved By Date By Date By Date ❑ F' -Electrical(4055) Approved B ., Date(),.. 3i(y El Rough ElectricalEl Final Electrical El Right of Way Approved Approved Approved By Date By Date By Date 12 - 1 0 2 -7- 3"9' ary of d, �r — _ FehilEGfWgim ELECTRICAL IP. 7/I Q /1 a- JUN 19 2012 PERMIT APPLICATION CITY OF FEDEW4Witmelectrical permits may be obtained on-line at www.cityoffederalway.com** ''WI ' �r.N ,*a�;'n., tir _ •Kr, .b;;�.a ..o .w ,i. :'. .... .8 z IDa; � ..,,,,mom .... SITE ADDRESS: 2- P 3� M/�RI N E V e W DR S W SUITE/UNIT/SPACE# ASSESSOR'S TAX/PARCEL# CURRENT/PROPOSED USE -- 5. I C 3 z 0 - 0 I 3 o .y(e ,F '( PROJECT NAME 1/ (Tenant or Homeowner Last Name) 1 V r 0 p p R C 51 c/t e v1 -e_ /1151-a 11Af7'01 o f q 5- _CA-AJ 501A r p ko-fZ ro 11- t c SYS o h PROJECT DESCRIPTION (0 Of D f �0 vie - 5 y e dl k'1 ema6.6 ',et V.4 (3o� s (i co-vi Detailed description of work to / , be included on this permit only E(V e r A U (6 S W jM 0 I(,t(t I atA pt S i[;Gell ElA-e 4/Q tl 5- 300 W /4 J ._ ...,',iii PRIMARY PHONE NAME PROPERTY OWNER Wcjt ft- a- Sh/Yley lCrop ( Z53) 6141- AA( MAILING ADDRESSGt / E-MAIL/ l' 33 0 /marl le vl NI T SW ��t�1)J0lg-bifi Q , (OM CITY STATE ZIP F�p Fed�ra( wtAY W4 9'5dy3 ( ) - NAME PRIMARY PHONE POO/ SCO/V1, Sdalr LLC (20b)76 - I/ 3( MAILIN6 ADDRESS E-MAIL ELECTRICAL q3 6 ( Raker Ave NW (t'l 2C° ,n,�l B f S uvK�I b(�v,(o wt CONTRACTOR CITY STATE ZIP FAX SeaHle Ir/4 9g(d7 (mob ) Y6- 1'13 / W STATE ONTRA OR' LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# PUge/-55'�rT ,'z log / )z NAME PRIMARY PHONE APPLICANT 444 Le _ (30 0 ) 2,z0 - c d 6 2- MAILING ADDRESS E-MAIL 9)o 5 0.6-ko, "file .47W oda h,0 -ycfs au 11'lerc,1 .e0 pil CITY STATE ZIP FAX Sea-ffie 1L1/ '7$/d 7 (zo(, ) .7o t - r9'3/ NAME PRIMARY PHONE PROJECT CONTACT „etiaritl 6c c (31Po ) Z1-0 - 572d2-- I 61-I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the C' of'ederal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such aim), .hick may be made by any person,including the undersigned,and filed against the city, but only where such claim arises •t of, e reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as \e„.p this application. SIGNATURE: MIDATE 1,/i1(12-- 1 PRINT NAME: i4-L7. /1i be—e-- 33325 '33325 8th Avenue South♦Federal Way♦WA♦98003-6325♦253-835-2607♦fax 253-835-2609♦www.cityoffederalway.com Bulletin#160—January 1,2011 Page 1 of 2 kAHandouts\Electrical Permit Application *elk . • . • • RESIDENTIAL COMMERCIAL NEW SINGLE FAMILY RESIDENCE NEW COMMERCIAL Total Square Feet 1 s(Service/Feeder Additional Feeders (including attached garage): 0- 100 amp '„ x$132.50 -x$ 80.50 FEES: First 1300 ft2-$122.00; 101- 200 amp x$164.00 x$103.50 Each additional 500 ft2 $39.00 201- 400 amp x$307.00 x$121„00 NEW MULTIFAMILY (3 units or more) 401 600 amp x$358.00 x$143.50 Is,Service/Feeder Additional Feeders 601- 800 amp x$463.00 x$196.00 0- 200 amp x $132.50 x $ 39.00 801- 1000 amp x$565.00 x$236.50 201 -400 amp x $164.00 x $ 80.50 Over 1000,amp x$616.00 x$328.50 401 600 amp x $224.00 x $111.50 601 -800 amp x $287.00 x $153.50 Over 600 volts surcharge x$103.50 Over 800 amp x $410.50 x $307.00 ALTERED SINGLE or MULTI FAMILY ALTERED COMMERCIAL 15 Service/Feeder 1st Service/Feeder Additional Feeders 0 200 amp x $10'1.00 0- 200'amp x$132.50 x',$103.50 201 -600 amp x $164.00 201- 600 amp x$307.00 x$121.00 Over 600 amp x $246.50 601 1000 amp -x$463.00 x$196.00 Over 1000 amp x$515.50 x$328.50 Added or Altered Circuits 1-4 circuits$80.50;each additional$8.00 Added or Altered Circuits 1-5 circuits$103.50;each additional$8.00 Mast or meter repair $60.50 Mast or meter repair $111.50 MANUFACTURED HOMES PLAN REVIEW FEES Service or feeder only x $ 80.50 Plan Review required only for: Service and feeder ` x $132.50 • New,or alteration to,service of 1,000 amps or greater • Medical/Educational/Institutional Facility $103.50 plus 35%of Permit Fee (Permit Fee x 35%= +$103.50=Plan Review Fee) Plan review for modified submittals $105.50/hour MISCELLANEOUS SERVICE/EQUIPMENT LOW VOLTAGE TEMPORARY SERVICE ❑ Fire Alarm System Is'Service/Feeder Additional Feeders 0 Security Alarm System ❑ Voice/Data Cabling 0- 60 amp x $ 71.00 x $ 32.00 O Other 61-100 amp x $ 80.50 -x $ 39.00 Area to be served by system: 101-200 amp x $103.50 x $ 51.00 1st 2,500 ft2-$71.00:each additional 2,500 ft2-$18.50 - 201-400 amp x $121.00 x $ 60.50 #of Thermostats 401 600 amp x $164.00 x $ 80.50 First$60.50;each additional$18.50 Over 600 amp x $184.50 x $ 92.00 FEE CALCULATIONS Yard Pole/meter loops/pedestal x$ 80.50 • Fees are determined by the scope of work as indicated. Portable Generator(transfer equipment) x$101.00 • A$6.00 Automation Fee will be added to all permits. Ditch cover/inspection only x$121.00 • For assistance in calculating fees or completing the application form,contact the Permit Center at 253-835-2607 33325 8`h Avenue South•Federal Way•WA•98003-6325•253-835-2607•fax:253-835-2609•www.cityoffederalway.com Bulletin#160-January I,2011 Page 2 of 2 k:\Handouts\Electrical Permit Application