Loading...
14-101492y ! Building -`Commercial., City of Federal Way Permit #: 14 -101492 -00 -CO Community &Econ. Dev. Services 33325 8th Ave S Federal Way, WA 98003Inspection Request Line: (253) 835-3050 Ph: (253) 835-2607 Fax: (253) 835-2609 FILL, Project Name: WILD WAVES - SHORING (WATER SLIDE & LAKE PROJECT) Project Address: 36201 ENCHANTED PKWY S Parcel Number: 282104 9026 Project Description: ADD - Shoring up for excavation/foundation prior to construction of new ride. Owner ApRlican Contractor Lender CLP ENCHANTED VILLAGE LLC ALLEN-BRADBURY ALLEN-BRADBURY OWNER IS LENDER 36201 ENCHANTED PKWY S CONSTRUCTION LLC CONSTRUCTION LLC FEDERAL WAY WA 98003-7109 901 ALGONA BLVD N ALLENCL030KE (6/25/14) ALGONA WA 98001 901 ALGONA BLVD N ALGONA WA 98001 Census Category: 565 - Fence/retaining wall Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load:- Floor oad:Floor Areas . ft. 0 0 1 0 1 0 Additional Permit Information Mechanical to be Included?....................................No Permit for Building Shell Only9 .............................No Special Inspection(s) Required?.............................Yes Number of Stories.................................................1 Plumbing to be Included?.......................................No New / Additional Sq. Feet - Total .......................... No Fixtures Associated With This Permit It CONDITIONS: 1) Temporary and permanent Erosion Control must be installed per approved plan immediately upon issuance of this permit. Schedule inspection with PW inspector. 253-835-2732. PERMIT EXPIRES Tuesday, November , 2014 Permit Issued on Thursday, May 1 I hereby certify that the above information is correct and that th r on the above described property and the occupancy and the use will be in accordance with the nd regulations of the State of Washington and the C' Way. Date: -!� I& /]''% Owner or agent: a THIS CARD IS TO MAIN ON-SITE t Construction In ection Record Federal Way INSPECTION REQ TS o : (253) 835-3050 PERMIT #: 14 -101492 -00 -CO Address: 36201 ENCHANTED PKWY S Project: CLP ENCHANTED VILLAGE LLC FEDERAL WAY, WA 98003 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. ❑ Footings/Setback (4110) ❑ Foundation Wall (4115) E:] Drainage/Downspout (4040) Approved to place concrete By Approved to place concrete Approved to backfill By Date By Date By Date ❑ Re -steel (4215) Slab/Concrete Floor (4255) Final Electrical Approved Underfloor Framing (4285) By Approved to place concrete or grout Approved to place concrete Date. Approved to sheath floor By Date By Date By Date Floor Sheathing (4105) Shear Walls (4245) Roof Sheathing (4220) Approved to install flooring Approved to install siding Approved to install roofing By Date By Date By Date Fire/Draft Stops (4095) Framing (4120) Prior to scheduling a Framing inspection; Approved Electrical, Plumbing & Mechanical Rough -in and Approved to insulate By Date Fire/Draft Stop inspections must be signed -off and By Date approved. IBC 109.3.4 Insulation (4150) Gypsum Wallboard Nailing (4130) [:] Suspended Ceiling Grid (4265) Approved to install wallboard Approved to install mud & tape Approved to drop tile By Date By Date By Date Final - Fire Department (4060) E] Final - Planning Approved Approved f1 By Date 5 , _ By Vt4vjow&Date j5' 0 Final - Building (4050) CA GI/IC. Approved By Vj4 Date r5 20 1 S Final - Public Works (4080) Approved By Aym 10o~ Date�- Rough Electrical Approved Final Electrical Approved Right of Way Approved By Date By Date. By Date .��01VED PERMIT OAPPLICATION Federal Way APR 0 2 2014 CITY, OF FEDERAL. WAY PERLtiT NUMBER / _ U C/ �( _ �I TARGET DATE SITE ADDRESS -3201 ��eH 1TZI_17 PARKWAY 5. FUtML WAy jeof)�3 PROTECT VALUAT/�IOR �, o o ZONING ASSE880R'S TAE/PARCEL f — TYPE OF PERMIT XBUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENnoN NAME OF PROJECT I V r-- W WATE�K j L (19� PROJECT DESCRIPTION Detailed description of work to be included on this permit only ���1/� 2HOF—1 vk ` �V -T1 �"'P PROPERTY OWNER L I�XME F� COA v3tP ) LIAO F ''� 9 32 [- O 7 c, mwto I.AuaNG ADD PAAKWq Vii tY wA IE� WAY TA I zkboo CorA MEN -BWNA K5FfzvCTorJL2967-7194- CONTRACTOR �{{ e �j jA, f ''^'r�lvli fJi►V / `6 ` � 1 T i-mAmr-te-OVA90 � 10 Cb 5Tk0C r, 4N " C' i Lam/®l (A 5) -J (� EEPMATION DATE IT" �c�AY BUBD�IjE80/L�j�J 11SS S. 0 V �� r a l w x644 JR4 .00- NAM^� NAM SAME A 5 66 I V T �C -ro P. PAOIART MOM XAu.Dta ADDRESS 3 -NIM APPLICANT CTff STATE zlP TAE PROJECT CONTACT 'RICH rRLyARY mons NAILINaADD> � t O� L satsu. rMe individual to receive and respond to all correspondence concerning this application) c1Tr STATE I ZIP PAX PROJECT FINANCING "mzM L- - N CO A i F OWNER-FllVANCZD Required value of $5,000 or more (RCW 19.27.095) NAILING ADDRESS, CITY, STATE, ZIP PRONE I cert{fy render penalty of perjury that I am the property owner or authorised agent of the property owner. I certVy that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I cert(fy that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arise* out of reNareos the city, including its offl— and employees, upon the accuracy of the information supplied to t a this app n. SIGNATURE:�°�'�DATE ""� 126,14 PRINT NAE: '^^� M M Bulletin #100 -January 1, 2013 Pagel of3 k:Wandouts\PaTnitApplication 3L 1 IVALUE OF MECHANICAL WORK as part ojthis project. Do not include exisdr q fixtures to remain GAS PIPE OUTLETS OTHER (Describe) HOODS (c..-,cja4 HOT WATER TANKS (G..I REFRIGERATION SYST WOODSTOVES `VALUE PLUMBING PERMIT NA CRITICAL AREAS ON PROPERTY? WATER PVZVWOR OF ®ING WORK MECHANICAL PERMIT N/A Indicate how many of each type of Axture to be installed or rel. to be installed or relocated as part AIR HANDLING UNITS FANS LAVS (Hmdsha* AIR CONDITIONER FIREPLACE INSERTS DISHWASHERS BOILERS FURNACES OTHER (Describe) COMPRESSORS GAS LOG SETS VACUUM BREAKERS DUCTING GAS PIPING IVALUE OF MECHANICAL WORK as part ojthis project. Do not include exisdr q fixtures to remain GAS PIPE OUTLETS OTHER (Describe) HOODS (c..-,cja4 HOT WATER TANKS (G..I REFRIGERATION SYST WOODSTOVES `VALUE PLUMBING PERMIT NA CRITICAL AREAS ON PROPERTY? WATER PVZVWOR OF ®ING WORK VALUZ OF ZXnl G nCM0VE2ENTS $ Indicate how many o each type offixture to be installed or relocated as part o this project. Do not include existingfixtures to remain. BATHTUBS ("Tub/sbowacombo) LAVS (Hmdsha* TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS patch ./CumW WATER HEATERS (m.e uic) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FECTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PVZVWOR SEWER PURVEYOR VALUZ OF ZXnl G nCM0VE2ENTS E70STnt6/PREVIOUS USE LOT SIZE On Sq— Peet) E7QSTINO PIKE SPRDUUJM SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? o YeSA No a Yes P< No Bulletin # 100 — January 1, 2013 Page 2 of 3 UHandoutsTermit Application • • 0 MAYES TESTING ENGINEERS, INC. x April 10, 2015 City of Federal Way Building Division PO Box 9718 Federal Way, WA 98063-9718 Re: Wild Waves Green Slide Replacement 36201 Enchanted Parkway South Federal Way, WA Project No. T14079 To Whom It May Concern: seswea" 20225 Cocty VAy Road stke 110 LMNA)Od. WA 98036 ph 425.7.12.9360 fax 429 7451737 Taco" Office 10029 S Tamm Way Sri E-2 Tacxxna WA98499 ph 253.584.3720 tax 253.584.3707 FbrdV dOffiW 7911 NE 33rd Drive Sum 190 Pbftx;. OR 97211 dr 503231 1.7515 Final Letter W5W2B17579 Permit # 14-101492-OOCO This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent to you. Special inspection was provided for: • Proprietary Anchors 1. Epoxy Grouted Dowels • Reinforced Concrete • Structural Steel Erection 1. Bolting 2. Steel Decking To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to. the city approved drawings, or engineer approved changes. We trust that this provides you with the information, which you require. Should you have any questions give us a call. Sincerely, Mayes Testing Engineers, Inc. Dennis Sanborn Senior Project Manager 7-777 -7-1 Corporate Office: Southwest Regional Office 1220 S. 356th SL, Federal Way, WA 98003 634 Rock Springs Rd, Escondido, CA 92025 253.838,1462 Voice • 253,874,6574 Fax 760233.5888 Voice • 760,233.5838 Fax May 28, 2014 Allen -Bradbury Construction 901 Algona Blvd North, Suite A Algona, WA 98001 Attention: Rich Moore Re: Wild Waves Green Slides Replacement Federal Way, Washington Shoring Permit Detail I on plan sheet 6 of 7 in the Wild Waves shoring design plans shows a minimum overlap dimension of 3 -inches for the lagging boards at the wall comers. I understand that the asbuilt condition of a comer board at the project has been observed to not meet this 3 -inch minimum overlap. We consider the asbuilt condition of the comer lagging boards to be acceptable. A zero overlap dimension actually meets the structural requirements of the lagging. Sincerely, DONALD B MURPHY CONTRACTORS, Inc. dba DBM Contractors, Inc. Paul Groneck, P.E. Vice President www.dbmcontractors.com General, Civil and Specialty Geotechnical Cwtstruction Alaska: 11875; Arizona: ROC187641; California: 462599; Colorado; Hawaii: CT -14938; Idaho: 11346 -AAA -1-2-, Montana: 45788; Nevada: 56788; Oregon: 64695; Utah: 4996804-5501; Washington: DONALI*331 RQ; Wyoming l- "i I -i I T I WAT11A Corporate Head Office Whtewater West Indcstnes Ltd • 6750 McM!lar Way - Rlc+oncl • B C - Cagaoa • V6:V 1-7 Tel (604) 273-1066 • Fax 604, 273-4518 • E'na' wrdewateoi@whlewaterwes: ccm ' CERTIFICATE OF INSPECTION This certificate is to confirm the undersigned has inspected the Whitewater Waterslide Complex at: Wild Waves Themepark Federal Way, WA consisting of: 1 - Enclosed InnerTube Ride - 497.8ft 1 - Open InnerTube Ride - 51 Oft 1 - Constrictor c/w InnerTube Ride - 431.4ft . Which appears to be in general conformance to Whitewater's engineering drawings and specifications for project #:31545 subject to the following remedies: ,1 ---------- I,! i; I I I i lit EST. tNQ .— lo -Ater Sigs an ` i/hit�Vt _?:%stries Ltd. Engineer ,:may= G i day of 20. 15 I- 0.-4– OHI H d orporea ce Whitewater West Industries Ltd. • 6700 McMillan Way. Richmond . B.C. • Canada . V6W 1J7 Tel (604) 273-1068 • Fax (604) 273-4518 • Email: whitewater@whitewaterwest.com COMMISSIONING CERTIFICATE This certificate is to confirm the undersigned has inspected, the Whitewater Waterslide Complex at: Wild Waves Themepark Federal Way, WA consisting of: 1 - Enclosed InnerTube Ride - 497.$ft 1 - Open InnerTube Ride - 51 Oft 1 - Constrictor c/w InnerTube Ride - 431.4ft • Which appears to be in general conformance to Whitewater's engineering drawings and specifications for project #:31545 subject to the following remedies: The ride is operational, safe, and ready for public use in accordance with the Operations and Maintenance manual provided. Signed this 1 '� day of020 S Doug Daneliuk , WhiteWater West Industries Ltd. Representative Corporab Head ofNco Whitewater West Industries Ltd. • 6700 McMillan Way • Richmond • B.C. • Canada • V6W 1 J7 Tel (604) 273-1068 • Fax (604) 273-4518 • Email: whitewaterGwhitewaterwestcom CERTIFICATE OF SUBSTANTIAL COMPLETION Definitions: Substantial completion shall be defined as the time when the Work is ready to be used, or is being used for the purpose in which it was intended. Contract Number: 31545 Project Name: Wild Waves Themepark Project Location: Federal Way, WA Date: A p,,r- - t �' _9�0 15- In 5In accordance with the above contract dated 20 -Dec -13 between (CONTRACTOR) Wild Waves - Enchanted Parks, Inc. and (SUBCONTRACTOR) WHITEWATER WEST INDUSTRIES LTD. This is to certify that the Work described therein has been SUBSTANTIALLY COMPLETED • on this I ' __ _ day of 14 p CI , 2014 DEFICIENCY LIST TO: Whitewater West Industries Ltd. 6700 McMillan Way, Richmond, B.C. Canada V6W 1J7 DEFICIENT ITEMS: VALUE Corporate Head Office Whitewater West Industries Ltd. • 6700 McMillan Way • Richmond • B.C. a Canada • V6W 1J7 Tel (604) 273-1068 • Fax (604) 273-4518 • Email: whitewater@wwhitewaterwest.com CERTIFICATE OF TOTAL COMPLETION Definitions: Total completion shall be defined as the time when the Work is Substantially Complete and all items on the deficiency list have been completed to the Owner's satisfaction. Contract Number: 31545 Project Name: Wild Waves Themepark Project Location: Federal Way, WA Date:0 In accordance with the above contract dated 20 -Dec -13 between (CONTRACTOR) Wild Waves - Enchanted Parks, Inc. and (SUBCONTRACTOR) WHITEWATER WEST INDUSTRIES LTD. This is to certify that the Work described therein has been TOTALLY COMPLETED .2 U i5 on this % T day of 204 SIGNATURE OF OWNE'S AUTHORIZED REPRESENTATIVE DATE Name: .. — 1 �'-2015. SIGNATUREOF EWATER AUTHORIZED REPRESENTATIVE DATE Name: Doug Daneliuk OFFIs tN,:,Cattada, USA; Brazii,'U,K:, Spltn ac#Asaa;` Varv�l�C.thliteYliatefVlf�tconl 0 • • IVB LETTER OF VALIDATIO The CWB acknowledges that Warnaar Steel Tech Ltd 137 Cambro Road, Kelowna, BC V 1 X 7T2 Canada is certified to CSA Standard W47.1 "Certification of Companies for Fusion Welding of Steel" in DIVISION 2 for the period July 28, 2014 to August 27, 2015 Company Code: WARNA1 Scope: Fabrication and installation of structural steel, miscellaneous metal and decking for buildings; fabrication of support steel for water slides, power stations and sawmills. Registrar The product certification system operated by the Canadian Welding Bureau most closely resembles that described by ISO/IEC Guide 67, Conformity assessment — Fundamentals of product certification, System 6. KG Atw.�NM Elil� 8260 Parkhill Drive, Milton, Ontario L9T 5V7 o 1-800-844-6790 1 kit 905-542-1312 1 Fax: 905-542-1318 Email: info®cwbgroup.org I Web: www.cwbgroup.org OEM 4, * 4 44k Canadian Institute of Steel Construction is pleased to recognize Warnaar Steel Tech Ltd. 137 Cambro Road, Kelowna, BC V1 X 7T2 for successfully meeting, through an accredited third party auditor, the quality certification requirements for the CISC Standard Scope: Fabrication of Structural Steel Initial Registration: May 13, 2011 c i sc I icca QUALITY/ CERTIFIED STEEL STRUCTURES Steel Structures Date of Issue: June 17, 2014 ::6Cu9,46., President Certificate Number: 086 Date of Expiry: May 13, 2015 0 • • • 800 Atlas Tube Customer: 86674604 Atlas ABC Cora to►las Tuba CMCaB Date: 11.29.2013 1s55 East 122nd street Cuatofnar: 2426 Z apo, ininois, USA O O O JMC STEEL GROUP Tel: 9 773.6464600 Fax: 773-646.6128 MATERIAL TEST REPORT 62M to shmpad to Wilkinson Steal Metals Ka Wilkinson Steel Metals - Ka WilWest A�baska Street 625 West Athabaska Street KAMLOOPS626 w J4G 1 E6 CANADA BC J4G 1 E6 CANADA Materiel- 2.0x1.0x125x24'0'018x10>. Material No: 200101262400 Mads W. USAMelted M: USA Sales order: 889038 Puralwta Order, P31127RIMK Heat No C Mn P S Sl At Cu Cb Mo NI Cr V TI 8 N ......._........_.._� _».»»............._. __...._..._...... .-._ ...... _.- - H1923 0.130 0.340 0.007 0.0111 0 0 0.024 0.047 0.140 0.002 0.020 0.080 0.070 0.001 0.001 0.000 0. 009 Bundle No PCs Yield Tenant E1n.2GAfAoatlon 1n CE: 0.22 _ _ _ »._ »......._»_..-..._....»». W002010558 08@500 Pal 070200 Psi 91 % » » ABTM A500 -10A GRAVE s&C Materiel Note: Sales Or.Nets: Material: 1.25xl.25xl26x24.0'Oltoxi0l.-CSA Materlel No: 0120121252400 -CSA Made In: USA • Melted N1: USA Sales order. 884081 Parahaee Order: P31107Rw4K i� Heat No C MR P S St Al Cu Cb Mo NI Cr V Ti B N Y87963 M0.170 0.600 0.012 0.006 0.015 0.049 0.020 0.004 0.003 0.010 0.040 0.001 0.001 0.000 0.008 Bundle No PCs Yield Tenalle Eln.21n Cergfbadon CE: 0.27 M800145786 100 070110 Psi 080610 Pel 28 % CSA 640.21.13 60W CLASS C Material Nota: asks Or.Nob: Materbd: 1.6x1.6x125x24'0`0t8x8I.GRC-0 MsterW No: 0150151252400-D Meals i:- USA Melted W USA Seas order: 869038 Purchase Order. P31127WOOK Hest No C Mn P 8 81 Al Cu Cb Mo M Or d 702507 �» 0.190 » 0.7800 0 0.010 - 0.011 0.007 0.036 0.000 0.000 0.000 0.000 0.000 0.001 0.001 0.000 0.0 Bundle No PCs YleW Tonle Etn.21n CE: 0.92 M300718185 84 070866 Pei 079729 Pal 25.0 96 ASTM A600-t0A GRADE C Materlel Now Salsa Or.Nots-, Mwvin PMNps Auowlzed by Quality Assurance: The results reported on this report represent the actual ettributea of the matalel hndeMd and Indicate full -Wane whh ler apPilcable speolfloatlon and contract requkements. CE oeleoWted using the AWS 01.1 owduod. 9 ge Pa : 1 Of 4 cutN Inatltat8 �`-/ or uosro eraaccs 10 3 - 4 300 �3 " Lo SOL9--A DIV OF SAMUEL --.- a o INC 1'�l1.1 C ora 888 8E MARINE OR Nm� "NAL "4rnS M. VANGOuvER BC V5X 2V3 CANADA SIS WMNSON STEEL. & METALS To.. 888 s E MARNE OR (MRL CERTIFICATE SCANNER) VANCOUVER BC VOX 2V3 CANADA LOT 6 DESCMPTION yip P�HYSMAL TS TES HEATS PBL POOR Urn P31217RB002V .015 .029 SE1310427702 Nucor Sbd . Ssatl4► qac 49,.025 70.208 26.6% SE13104M 1*Q-1& Fhd .17 .83 A10 20'A38M4W 49.393 71,121 28.6% .12 CSA G4021-13 44W/ASTM A3WA391M 341MPa 490MPa .002 .020 12 ASTM A70SlA708M-13 GR 38 X q t1 ASME SAW2010 EDMON-2011 A" NDA ASTM A3WA304-12. A709fMOM_13 G R36. ASW BA36-10 Ed'11 Ad. POB 03. P31217RSDM SE1310667801 Nucor Bad - Song Inc 58.061 81.473 21.1% SE1310l M 1W on) ft"W 400MPa 582r*Pa 20' 44W 58.228 81,084 2&0% CSA 0402104 OR 44IN 401MPs 589MPe PCO"> P31217R8002V 30310MMI NucorBad - Swft Inc 58,812 81,981 26.0% SE13105877 1/2' (.3000) Round 390MPa 58SWg 20'44W 66XT 81,882 24.2% CSA G40.2f-04 GR 44W 3B8MPa 565MPa PCiBae P31217R8002V SE1310MOM Nucor Sad-aae"Inc 51.937 74.500 27.3% SE13105806 tz4 pat 358MPm 314MPa W NUCOR MIA.TXLv" 61,457 74.300 27.3% MUCOR MULTKUMDE 355MPe 612MPa = aiaab,..iecity tl+rc iLa an -4 CERTIFIED MILL TEST IMPORT ship Brom: Nucor Shed seethe, InG 2424 Sw Andover BATTLE. WA 98106-1100 208.833-2222 C--,-] mn---1 P 2 B.L. Number. 481 3 LOW Number. 2=19 .16 .90 .011 .039 .18 .36 .10 .11 .030 .018 .001 .18 .91 .013 .037 .23 .33 .38 .13 .16 .030 .004 .00i .17 t.t i1a10 i�piis r aic "' ••� alit .95 .015 .029 .19 .33 .41 .11 .22 .020 .006 .001 .17 .83 A10 .082 .17 .30 .09 .12 AM .021 .002 .020 PB t1 It «uattr cavi sipitb. - -- 00/ �.i .rteaa aai P�ioie as Baia aat�cLi. 1.1 MifiYty. ■Mi 3Y Wa Iritai ii�iN. arwt eei aii., ead w a7r Awa >WLQY1a la aey NN QUM= O.e tw k tNs .rurfai. i3 e=tk W.mma The Lincoln Electric Company 22801 St Clair Avenue Cleveland, Otic 44117-1199 Product: Outersh(elde 70 Classification: E70T 1 C -H1 S, E70T 9C -H9 S Specification: AWS A5.20-2005, ASME SFA -5.20 Test Completed: April 30, 2009 CERTIFICATE OF CONFORMANCE (APPLIES ONLY TO U.S. PRODUCTS) HUH411-4-0-16- I ELECTRIC [3 Year] This is to certify that the product named above and suppled on the referenced order number is of the saner rsSi6eation, manufacturing process, and material requirements as the material which was used for the test that was concluded on the date shown, the results of which are shown below. Al teats required by the specifications shown for classlHca tion were pwfonned at that tine and the material tested met all requirements. It was manufactured and suppled according to the Quality System Program of the Llneoln Electric Company, Cleveland, Ohio, IJ.SA. which meets the requirements of 1809001, NCA38W, ANSI/AWS A5.01, and other specification and Mirdwy requirements, as applicable. The Quality System Program has been approved by ASME. ABS, and VdTlJV. Operating Settings AWSIASME Requirennerds Results Electrode Size Yield Strength, 0.2% offset Ups Graf) 1110 inch 8/32 Inch Polarity DC+ DC+ DC+ Shielding Gas (per AWS AS -12) 100% CO2 (SG -C) 1 W% Cos (SG -C) 100% CO2 (SGS) Voltage, V Avg. Charpy V -notch Impact Properties...................... 25 29 Wire Feed Speed, cm/min (Inhnln) Joules Q -29'C (ft -lbs Q 20 OF) 698 (250) 508 (200) Current, amps Avg. 275 470 Heat input Avg., kJlmm (kJlin.) Jtea -18'G 0' 1.5 (37) 2.0 (62) Contact 11p to Work Distance, mm On.) 25 (1) 25 (1) Passes/Layers 1417 915 Preheat Temp, -C ('F) (60 min.) 20 (12) 25 (/4) Interpass Temp, 'C 75.323 165 28 lel OM Mechanical arooertlee of the weld deooelts (In the as -welded cond)tionl Tensile Strength. MPa (taq (76-96) 580 (84) 610 80) Yield Strength, 0.2% offset Ups Graf) (58 min.) M (76) 520 (76) Elongation, % 22 min. 28 29 Avows Hardness Rockwel B Not Required 91 91 Avg. Charpy V -notch Impact Properties...................... 0.03 max 1-2 33 (24) Joules Q -29'C (ft -lbs Q 20 OF) (20 min.) 74,8M,88 (66161.65) 17,36,37 (20.28,27) Avg. 9646 89)6973 X3)3 Jtea -18'G 0' (20 min.) 94,K96 41 6 M Chemical cornaosiHon fwelafat %1 C 0.12 max 0.04 0.07 Mn 1.75 Haut 1.36 1.46 Si 0.90 max 0.62 0.67 S 003 max 0 01 0.01 P 0.03 max 0.01 4.01 The strenand elongation properties wars obtained from 12.6 mm (0.000 in), A4 tensile specimen attl8daily aged at I WOC (220 °F) for 48 hours, as permitted by AWS A6.20- 2006. A naturally aged tensile specimen may take months to schism the speoilbd properties. See AWS AtI 202005, paragraph A8.3. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical structure of the weld. deposit and other factors. ' fy0, 9 D Fble gen paA A4.3 16.0 max 7.8 10.4 5j ". AbsoluM HamidRy (pralnra mobturolAr dry alb 51 51 gth This oerllleate complies to the requirements of EN 10204, Type 2.2 James R. Fogie, C;srVftaM Supervisor Date Radiographic Teat: Met requirements. Filet Weld Test: (postlons as required): Met requiramerts. Test assembly constructed of AX The electrode diameters required to be tested are 8l32 In. and 1116 In. the 9184 In. sine will also 'l meet to" requirements. z Resub below the detection Omits of the irrat urnent or lower than the precision required by specffioalon are reported as zero. David A. Fink, Manager, Compliance Engineering, Date Strength values in SI units are reported to the nearest 10 MPa converted iron actual data. Preheat and ederpess temperature values Consumable R&D Department in SI unks are reported to the dearest 5 degress. Page 1 of 1 Cert. No. 13100 The Lincoln Electric Company CERTIFICATE OF CONFORMANCEs 22801 St Clair Avenue MFM Cleveland, Ohio 44117-1199 (APPLIES ONLY TO U.S. PRODUCTS) THE WELDING EXPERTS' Product: Outarshield• 71M [1Yearl Classification: E71T-IC-J, E71T-1C-JH18, E71T-11114, E71T-111014H1S, VIUC-J, E71T-9C-JH1S, E71T-91101.i, E71T-8M.1H1S Specification: AWS A8.20:2005, ASME SFA -8.20 Date Dscember 03, 2010 This is to certify that the product named above and supplied on the referenced order number is of the same classification, manufacturing process, and material requirements es the material which was used for the test that was concluded on the date shown, the results of which are shown below. All tests required by the specifications shown for classification were performed at that time and the material tested met all requirements. It was manufactured and supplied according to the Quality System Program of the Lincoln Electric Company, Cleveland, Ohio, U.S.A., which meets the requirements of 1SO9001, NCA3800, AWS A5.01, and other specification and Military requirements, as applicable. The Quality System Program has been approved by ASME, ABS, and VdTUV. Operating Settings Electrode Size Polarity Shielding Gas Voltage, V Wire Feed Speed, cm/min (In/min) Current, A Average Heat Input, kJlmm (kJ/in) Contact Tip to Work Distance, mm (in) Pass/Layers Preheat Temperature, 'C ('F) Interpass Temperature, 'C ('F) Postweld Heat Treatment Mechanical properties of weld dspostts AWSIASME RESULTS 560 (82) 1/16 Inch 1/18 inch (58 min.) DC+ DC+ Elongetion 100% CO2 (SG -C) 25% CO2,75% Ar (SG -AC -25) 27 28 24 139 (103) 835 (250) 880 (280) 0,03 max. 280 320 Average Impact Energy 1.5(38) 1.5(38) 188 (139) 25(l) 25 (1) 13R 14/7 (60 min.) 20 (66) 20 (71) (275 - 325) 150 (300) 150 (300) As -welded As -welded As -welded Tensile Strength, We (ksl) — (70-96) 560 (82) 630 (92) L. Yield Strength, 0.2% Offset, MPa (ksi) (58 min.) 510 (73) 580 (84) Elongetion 22 min. 28 27 (~ Average Impact Energy (20 min.) 0.05 148 (109) 140 (103) 240Fl 1.20 1.49 14LIM.100.LIM..10711� 13 J40-144r1o1.19�.� 5 • Average impact Energy (20 min.) S 173 (127) 139 (103) ._�_71.971,1 P 0,03 max. 6 (126.126, .3 0.01_ Average Impact Energy (20 min.) 188 (139) 152 (112) $5,187.193 (.137.13 ..152.10 11.0.112.1 �—,Average Hardneas.HRB Not ftegulred _ 88 94 Chemical composition of weld deposits (wslght °/.) C 0.12 max. 0.05 0.06 Mn 1.75 max. 1.20 1.49 Si 0.90 max. 0.31 0.50 S 0.03 max. 0.01 0.01 P 0,03 max. 0.01 0.01_ Page 1 of 2 Cert. No. 14160 0 • • The Lincoln Electric Company 22801 St. Clair Avenue Cleveland, Obio 44117-1199 CERTIFICATE OF CONFORMANCE (APPLIES ONLY TO U.S. PRODUCTS) Product: Outershield' 71M Classification: E71T-1C-J, E71T-1C-JH16, E71T-1M,1, E71T-1M,1H16, E71T-SC-J, E71T-SC.I1-116, E71T.111M.1, E71T-911014H1B Specification: AWS A520:2006, ASME SFA -620 Date December 03, 2010 Diffusible Hydrogen (per AWS A4.3) IrElectrode Size Polarity Shielding Gas Diffusible Hydrogen, mtJ100g Absolute Hum Idityjgrains moisture/lb dry aid_ Requirements RESULTS 1116 inch 1116 Inch DC+ DC+ 100% CO2 (SCC) 25% CO2, 75% Ar (SG,AC-25) 18.0 max. 11.3 14.4 25 25 1. This certificate complies with the requirements of EN 10204, Type 2.2 2. The electrode size required to be tested for this clessi5mlion is 1/18 Inch. The 0.035 inch, 0.045 inch and 0.052 inch sizes will also meet these requirements. 3. Test assembly oonstructed of ASTM A38 steel. 4. Fillet Weld Test (positions as required): Met requirements. S. Radiographic Inspection: Met requirements. S. The strength and elongation properties reported here were obtained from tenalle specimens artificially aged at 106°C (220°F) for 48 hours. 7. Results below the detection nmlts of the Instrument or ower than the precision required by the specification are reported as zero. Strength values in Si units are reported to the nearest 10 We converted from actual date. Preheat and interpose temperature values In SI units are reported to the nearest 5 degrees. Lf IV COL KI ELECTRIC GNMER" -wpraw "� December 03, 2010 J.R. Fogle, CertHicationnLG Supervisor Date 4, December 09, 2010 Dave Fink, Manager, Compliance Date Engineering, Consumable R&D Page 2 of 2 Cert No. 14160 • • I-- o R E e Ezsac E Procedure Qualification Record No. FC102-1 earl 9C1GM1C P�R��pMANC4 v Proc�sCs(WA es) e: 10��,� i�lEMl�AUUTT01&= BASE MATERIALS POSTWELD HEAT TREATMENT Material Spec.: SA572 Temperature: NONE Type or Grade: Grade 50 Time: WA Group#: 11 1 To Group#: II Other. Thickness of Test Coupon: 3/4" SHIELDING Diameter of Test Coupon: N/A Percent Composition Gases) Mixture Flow Rate FILLER METALS Shielding CO2 100% 37 - 45 CFH AWS Spec.: 6.20 Trailing None AWS Class.: E70T-1, 9 ELECTRICAL CHARACTERISTICS Size of Filler Metal: 5/64" dia. Current DC Other. Uncoln OUTERSHIELD 70 Lot # 11472992 Polarity. Electrode Positive (Reverse) JOINT DESIGN WFS: 159 IPM Volta: 26 Type: Butt (Bevel Groove) Backing: Yes Transfer Mode: (GMAW) Globular O Spray O WAO Root Opening: 1/2" Backing Material: A36 Heat Input 23.4 KjAn, all passes within + 20% Groove Angle: 450 Root Face: 0" Other )dmate Amps = 300 Other. TECHNIQUE POSITION Travel Speed: 20 IPM Position of Groove: 2G String or Weave Bead: Stringers Weld Progression (Uphill, Downhill): N/A Oscillation: None Other: - Contact Tube To Work Distance: 1-1/4" PREHEAT Gas Cup Size: 50' Preheat Temp.: 70"F Muldpass or Single Pass (per side): Multiss Interpass Temp.: 1 WF Maximum Single or Multiple Electrodes: Single Other. Other. Interpass Chip, Brush, Wor Grind as Required JOINTS - a R +{ T. Page 1 of 2 • • • • M o m E B Fz^c E- Procedure Qualification Record No. FC102-1 V �— B : WC , Date: 10/03110, icab erF"o s): N/A � ProcessFCAVV—Tgpe SEMI-AUTOMATr0— ALL WELD METAL TENSILE TEST Specimen Width Thickness Area Ultimate Ultimate Unit Other No. Temp.(R-Lbs) Weld #1 Tensi%Load, Stress, psi 70OF #1 WA .498 .1948 18,143 93,140 81.14KS n27% GUIDED BEND TEST Specimen No. Type of Bend Result Remarks None TOUGHNESS TEST Specirn Specimen Notch Test Impact Values No. Size T Temp.(R-Lbs) Weld #1 .395 X.395 CVN 70OF 40 minimum Actual 100,100, 95 110 100 VT Results -Satisfactory: Yes X No Penetration Into Parent Metal: Yes X No Macroetch Results: WA OTHER TESTS Deposit Analysis: NONE Other: Hardness (BHN) None UT Accept - SME Adam Johnson Welder's Name Gran Wilcox Clods No. N/A Stamp No. GW Test conducted by American Metallurgical Services Laboratory Test No. 07-1377 We certify that the statements In this record are correct and that the test welds were prepared, welded, and tested in accordance with the requirements of Section 4 the AWS D1.1 (06) Structural Wei ing Code - Steel and Annex A of AWS D 1.8, Seismic Supplement Date 11/03110. By Richard Cook SME STEEL CWI # 96890991 t Page 2 of 2 J • • rI C O RE B RAC E` :.. Procedure Qualification Record No. FCt00-2o '..." Process(e ): 10/ Y� EMIW AUTOMAT BASE MATERIALS POSTWELD HEAT TREATMENT Material Spec.: SA572 Temperature: NONE Type or Grade: Grade 50 Time: WA Group* II To Group#: II Other. of Test Coupon: 314" SHIELDING -Thickness Diameter of Test Coupon: NIA Percent Composition Other Gas(es) Modure Flow Rate FILLER METALS Shielding CO, 100% 37 - 49 CFH AWS Spec,: 520 Trailing None AWS Class.: E71T-1 ELECTRICAL CHARACTERISTICS Size of Filler Metal: 1116" dia. Current DC Other. Uncoin OUiERSHI ELD 71 M Lot # 11414552 Polarity: Electrode Positive (Reverse) 'JOINT DESIGN WFS: 593 IPM avrg. Volts: 35.8 avrg. Type: Butt (Double Weld) Backing: Yes Transfer Mode: (GMAW) Globular O Spray O NIAO Root Opening: 112" Backing Material: A36 Heat Input: 85.92 Win, all passes within ± 20% Groove Angle: 450 Root Face: 0" Other 822MAmate Amg2 = 480 Other: TECHNIQUE POSITION Travel Speed: 12 IPM avrg. Position of Groove: 1 G String or Weave Bead: Stringers Nell Pmaresm WA phiOther: Osddatlon: None Contact Tube To Work Distance: 5/8 -1-114" Gas Cup Size: 518" PREHEAT Preheat Temp.: 300°F ± 25 Multipass or Single Pass (per side): Mutdpass Interpass Temp.: 450 minimum to 550°F modmum Single or Multiple Electrodes: Single Other. Other. Interpass Chip, Brush, Wor Grind as Required_ JOINTS T, _t •, Page 1 of 2 C] • n • • o4—oCa�E _ s, �R-„c E- — Procedure ceddCure Qutal•iication RecordNoFC O Pr—W�Dae--1 , A = e S):FCANV—' s)� MI-AOMAW ALL WELD METAL TENSIt .F TFCT SpedoTen Width Thickness Area ---------- Ultimate Tens5eml-oad, lb Ultimate Unit Stress, psi 86,790 Other #1 N/A .493 .1948 16,907 76 KSI yield 27% Elongation GUIDED BEND TEST Spec men Spe Weld #1 .395 X 70°F TOUGHNESS TEST IVT Results -Satisfactory: Yes X No Penetration Into Parent Metal: Yes X No Macxoetch Results: N/A 112,132,122 Deposit Analysis: NONE v nGR G.7 �7 Other. Hardness (BHN) None UT Accept - SME Adam Johnson Welders Name gM Wilcox Clods No. N/A Stamp No. GW Test conducted by: American Metallurgical Services Laboratory Test No. 07-1377 We certify that the statements in this record are torted and that the test welds were prepared welded and tested In accordance with the requirements of Section of WS D1.17-1 uctural Welding Code - S}eel andrAnnex A of the AWS D1.8 (06) Seismk Supplement Date 11103/10. By Richa Cook SME STEEL CWI # 95o9o991 Page 2 of 2 • �fR.,Y� �e�f��wfi,m tWiYlliliLyi V� T X �ti+��iV1I �. ♦s, psi, R7aR '�M/,I �s7i i��tl 1� , w : aunt MEAtir 30 ���� 1tMAS:Z" M�1yAl4�kl1 l m 4m At .�.=... ,,,._ MiY� Fi n4i fJ . .. : .. ...-:. , w b. .. ,.. -..� ,r ,. ...: •..xn,.;. ^ :.:u:.. 77 tries„ -s .. �l P` ,' � �e`tbut.t`a�'Ckkcoa�p+iq��lr�tf�.l. ' NMNARYAtAW NitlNkltlCMpbl ° ' - �'tRI�C'�R' �I�LM'r11ir71CAtCilbbR, d v , 0 0 0 N ' Mac nHHHmMMEF-3= mcmun MOW imwmmmmmm�� Ems iw&Rmmmmmm�� 0 0 0 r7A �_ff Z�4_jripI� MCCCLU MIE&WW� WL lkmmmm- , jlllltL,� 2MW2 sU jo3-1- It 'P3Oct t0I cizo01T ae..t so. 1-00098 (001) INSPECTION CE TI KATE Orte.es : SAM- SON & CO., LTD craar u 3-3T—A=-3—Y-1007 801 coroaitj STRUCTURAL TUBING amoller : NIPFONSTEELASMMMIMM PRO. ..witiostim: A500-C/3W Date of I== : 2m4 -01 -W OkW YS : ldd 9doWh YP: idd Pda G : Good We h—* cut* ymt the metwW haedn has been anile to the appl WHe spedlandw sod that teat t+ealts aetl* the requh+emeota ofdw cwb2cM vt.:arnlyzairan wm&�=n� w UL ft cbw of kjr&tCLI swwt sect. PM:(81-S)3630-2138 FAX:(81-3)3630-2159 man :: V14v 111 rer■■�■rr■r�■■■r■r■rr��■r ■e�� :.11 .11�■■r©r©r■■■■rr■�r� ■. �-� 111' fl ©r■®©��.' �■rr■r■-�- ,1 :_:1K Y .; 111 ��_--■ r■■■■■■rrrr■.r- I :•:IY, K JI 111 �r�■�■■■�r■■■r■■■■■■■■■�r■r ■■�r■■ �, ry .1.1.•.11 r■r©�r■rr■■r■�■�■■ 1 ::1K K 11 I ©" K'1 �-rr■■■■■■■■■■■■-r-I OkW YS : ldd 9doWh YP: idd Pda G : Good We h—* cut* ymt the metwW haedn has been anile to the appl WHe spedlandw sod that teat t+ealts aetl* the requh+emeota ofdw cwb2cM vt.:arnlyzairan wm&�=n� w UL ft cbw of kjr&tCLI swwt sect. PM:(81-S)3630-2138 FAX:(81-3)3630-2159 • • • Po -3-q a ai Tats S EVRAZ I =In mmmc m Z 27, 2013 1 fivm0mamsMl Am amass 2W sum ,r ow arm.- 54M CIJz1OMamM0. . *uZzattlow SW S nQVISi011 or Siler am is co 625 N. !'Bs O L 625 A. 33299BAN l 8r�'P »1QAODi6, 1!c 2va iC5 p311077tI003i d011m a D YANWOM, V2B 105 Ca 0 aomIla DOE 306393 11/27+/2013 74m uxrau IL mm Bial) AND POIAYD70 t09FT7 a wsommaxim AND PONCHAW ONION R801181a1o1Z8 CAIN am CSi• 33e1/ S'l 1Cr00�I. 'YDal CffA 6!0.21-04 6R= 35OK. [0321ML- YlBD1BIOLE %BDN3 HAFA 85 p(s DESCRFWN 1r No. sue Peax too PSI x toe r r % RA JOIN 3.000-i 3.600 Z 0.187 2 241 6 POP 990 L86 M00212 670 775 30 34 PCs 5610 LBO 1100589 685 815 34 3.000 Z 3.000 Z 0.2500 Z 48' 35 PCs 6330 IBM =0596 730 855 29 4.000 1 2.000 Z 0.2500 Y 48' 15 M 6330 ZW 1100215 685 770 32 1 3C 422 W 110035s 675 750 33 C Mn P Ou V Cb Cr Mo 71 6 N CA 600589 .17 .87 .011 .005 .26 .01 .06 006 .022 035 .03 .00 1100596 .17 .85 .011 .004 .25 .01 .06 003 .020 043 .02 .00 1100215 .14 .85 .014 .006 .24 .01 .OS 007 .005 040 .02 .00 3+[00355 .14 .86 .011 .008 .Z7 .01 .05 004 .005 042 .03 .00 (+)i rJ� 953. aLL Tai IcwdfyteaI - pfbeCWOOase-ftNwaIDNW oa. OfEVRAx11c.NA b • • • vo 3- w R EV i wn INC m W� RAZ 29 a6. 1013 2 Nut mm in mm = 1PII O11 M= a Am2aLB S1AC V= xszaclmo 1[ a BMTaLB 50503 CUSI0w610MMM 0 .625 33WODSWXAZr PAM, #% 635 XIMOVAUML VANW, #1 CUMUROOW, SC V%C 4C7 C 08:, 8C VIC. 4C7 P30102PSOO23 0 Can&= Ca11BWa jamm Ila T 2968" 02/26/2013 l Ns UaBK L HM 86E11 MANUS 01UP TEMM mo F+CUM'no rSErTM WOCrNMDM N D VURCH ss On nmwmolfs CBT 8561 BTROC7ruiu . CBL 060.11-04 BSIa1D: 350N. i'aP cNvtlllllaacNo. 9768x2 DBSC 'TIOPI VEW 02101M 7 EU %RM PARMS MQ. sue P8W = PM X 100 !r r %M No Z 0.9500 x 80 7122 PCS 6048 L8$ 10117846 680 810 28 4.000 s 0.1875 2 241 12 PCR 2712 L88 0816796 590 745 37 24 PCS 8760 Im TOTAW MQAm PN 71 B a I CE UM96 .14 .85 .012 .007 .24 .01 .03 013 .005 054 .02 .00 -XV DICA2 CD WXM it 30 NO m I 'LRB! =a. aLL 2m ..... Or Ilmowr.., lcetftftedmr-beeeanedam lm**rec*rftofEVRAZW-OM OV • • • Qo 3-i EVRAZ 1 e4WW-N ► ■~ of Colmrimirmamu. TIM CMINwa m WE -om EvrazOrponSbd 302821 0so 19, 2013 1 MILOWK OIQ[ s O L S'PJ1tL AM Azig S x1m laald .26 zmvxnOsf 0!' samom am a CO 695 W. AllmiukomS21iX6T 71II.1R wm 625 W. MMUBA8CL BrMZW 7CalELO0aP8, DC 2VX iC5 53483 C05101I RO MI a 9308272IOO= D imuzams, v2a iC5 CIL ismin T cain= siavews rta Omni O 302821 09/19!2013 7118YA71sY1LW00MAMMlFA Y9MA70.7BiFOUND70 NOWTHESPURCATIONSANDPURCHA61EORD9ARiOONE1EMM eat >M 8229C URAL T071a1B CSI► "0.21-04 Qr4= 33M. CAY� CANM uac K 6740 VRD TBMMLE x E1AN8 1>wnotEsa 00%=. OESCRUnM HERr NO. sue PBI,X 10o PBI X 100 r r %PA sen 0 X 4.000 X 0.2500 x 24' C8 24 9 7032 ISS =9113 635 790 34 72 PCS 21096 ZW M9852 700 785 33 4.000 X 4.000 X 0.2500 X 48' 12 PCs 7032 ISS ;� IM836 645 755 33 108 PCS 35160 ISS TOTa7.8 HEIrr M11 p N =9952 .13 .86 .012 .006 .24 .01 .04 007 .005 039 .02 .00 W9836 .13 .83 .012 .006 .21 .01 .04 008 .005 040 .02 .00 (;)I M RZM= s mr 2s! U". AM IMW UM 3 =AM UTTae ar 1cmWfheabovebbeamtietsm- I IinthenII I ofEVPA2W=MA BY • EVRAZI e4w,w-NA goer �� ate : tlYr�4genfrttl "� ° 309561 !mob 23, 2014 1 IYU.ORDBR I10. Nlii wnxn m ®Y'aEL Zig 301mw x1c imm W==== Y=cr&-Zmmwn 55070 a zmvzs= 0? sammm SOsi A CO 625 W. A25I ASCL 8R4tSEi' sismMOR MIA L 625 W. A2ULShBM SSRtOrP ,OOgg, BC 2VE 105 2401073moos C Mo 0 ia1Q,o0?S, V28 ICS CL T CA30M o Mu 309561 °aE 02/13/2014 t1Mj 3YR6WIL iUS 8E6M Y3NOFNC7i LTi6lED AND F001070 MEffj M iPB=. 4CSIlOfM AM P17RpiM O D 0MMOMMO : CST a0fsTstVCjV3UkL TatsIry a C9M "0.21-04 O 350N. amm as Qi11 GNVMU IU 04" D68CRIPTION ym rQ=ea NO. SLAB PDX too i6Y80.E PSI X 100 7%ai s r % RA wiam SM RAVACTS S.000 Z 5.000 Y 0. 500 Z 48• 9 PCS 6741 ZAB X01535 575 693 38 9 !CS7 6741 US TOTMA 14 V Cb AI B N Cr I CE 7OV31, (�) a TWO". ALL I= ...... 1 �estlb�naa0ereme�eoer aae dbauneaarcf VRaW_U► By • • • 1 euNY above to M �atrecYis contained in,* records of E vW NC. NA RV "r°ff OF`O"`�TUU 13, 2014 :: EVRAZI &&INC NA pslxrwl�i ti OnO� atwl un STMM mw MrAmw xm 7Cm Mmucnmm po0lS $O 7► =VT=GK cw mamm am as Co 62 M. MLSAD a Snl' cUS omia min 7�40206AX002M 625 M. S� 8 NC 2VA L 2MMA �s, vm ics C7► 4� N& T T c�a I& WE 309365 02/13/7 AND F Ct ATO &§Krn4R � AfO PtlIMx111St 0Mt3i R80lIMMIAEN�B OAIIRB♦t ]RS dill TM W08p11� WS gM UAMUiAtif iMM�M 2MMM Cs7► 440.21-04 mtWM 350M. �, WX �y uuutqua W 04" YRD TEMME %HANG gAlOW 11(P1YCT$ DESOFOn1CN HEAT N0. BLAB BBI loo FMX100 it 7 %RA MST 6.00 Y 0 Y 0.2 O Y 48' 6 we 5472 LBB pp0807 580 725 37 6 nes 5472 XaD T029" $ QI m NCX C . p AI N va *� i 'P� IIS1. am rs TM ma. 1 euNY above to M �atrecYis contained in,* records of E vW NC. NA RV • Ro 3 -1 EVRAZ I maw- NA OF Y "� 196884 Fab 26, 2013 3 NUORMIn WE = 0 WXLY23 M 8'1'!04 A 10VMLS 2110 VASC 625 nlMN'=AL YAW, ft MILXXIMOOW 8TH i 30MIL9 625 =D=rXnL WM, 61 50503 CN101NtOB0E K LLCR>1ROM. INC O1C 4C7 CR11Md>10008:, MC v1C 4C7 P30102=0018 Camm C1M117� JOBA� N0. WNW& off 0 296884 02/26/2013 'A1SUaNFULMM8BN1YAMMA UFAM.7ISMANDPOWIMYR8T11BtSPECFIC1TMSAINPIINCNA88OIIDlRII80U8WiNf8 CMT MW 82MOC29RAL TDE>1N COA "0.21-04 OIlI>1L! 3501/. GAWWR Ties 'TRDCIC= CAMRWi114 9788zss YENS" %ELM wimmm ILR�ICTS DESDRUYrMvw MMUNQ SLAB P81x100 Pwx= r r %AA BIW 3.500 Y 3.500 x 0.2500 z 481 12 PCs 6048 LES , =7846 680 810 28 4.000 X 4.000 Z 0.1875x24• i2 PCS 2712 LEO M6796 590 745 37 24 PC8 8760 LEs TOTALS MEff C W P Cu m V Cb Al7�02 N Ca CE I AW7540 .01 =M96 .k .85 .017 .007 .24 .O1 .05 013 .005 054 .00 (+) ! TSB;A= < TMM U&TS mx 31 D=Z&m Tu M. +ORT lcwSVft*a"ftbeoermaxsaI $in**, —e I a#MOMZW—WA ft • MILL. TEST CERTIFICATE HL,D CLA13K S'TF;M PlJ% CO,INC. Add: BUILDMNO. N134S81NDUS'R IAL MA7E S {fE-i1 SCTM- ROAD SOUTH.CLARK FRL•'EPORT ZONK, Cd.ARKRMA, PAMPANGA; p}IILIpPINES Tdo 0063453491501, 1+4x+ 0063434991382 fPttt'4:liase Order: PO # 404511 Certit[cate No.: 2013F)1041-2 Standard: ASTM A53 GRB Dame of Issue: Nov.24,2013 Dnaipdon:PR]Mt M,ttG`kt—PJIINT F.RW ,=- PLPES SMPplm Mark:HLD CLAkK/PO * 404311 HEAL' NUMSER/SIZE PCS PER BUNDLE /WEIGHT PER BUNEDLEIMADG RI PHlUPPtMFS I ®®�©© 8888®8888888�8��� 'We hemby certify that the matefial desaibed has been manufacturaCnspected, and tested in a=of.damc with above standard & 0 .11 • • 0 L a a v � !� O {{RViy-J) }yi M^ b pp O Q H N N N N b H N N N N O •��.++• Off ti .��•• o � m I wO�� �O• •�1 O 1 0 4 O 0 0 wO� O $ o A C! , N N sh M N N N N N •y • a O O O op O on gO� 3 0 0 U m m m ado 0. i, NX 10b 10 •O 11 If1 N N V7 V7 Y1 N ••��11 N N N N N N N N N N N N N N yy'��1 T� b M1 10 N N N N N N cm ••1' 1 8 8 88 1q�1pp• 88 qq �j 1M1p O f t v�M •11 1p� w! r1 L ■■ i p 8 0 1 Men m M1m M1 m d 00 • • 1 m � PS Vl M1 O Om a � •p w � apf � Iqf •p•! M a4N i® N W% •-• V" m w � v Mpppp� O n O W O w O O i y+i{ N MSN Mx C'n !SM wiM Mi Z�ijM=i 1 xM I xM I x�l• 1 x3 . l�;s 1Q~ rO 1p •C./ N 1p M N b •el M1 10 .710 i.r�i 2 b�M N �c -��'N b �Ci 7i N V N %4 !O P ([ill�� 1' w bm 3a 0i .-1 N E 8aM pa 301A CERTIFICATE NO. 2600420 PAGE 1 of 1 W8217;1 Gd9QIA1 rt;I f/K6 2051513 883-040 DATE OF ISSUE. :2012-06-04 Militia TEL:82-52-280-014.FAX:82-52-287-8816 CONITRACT(PIO) NO.: 403568 200074087 to . 28-8. JAMWON-DONG. COMMODITY : H.F.W. AIIH4 1 TEL:52-2-2112-8114.FAX:82-2-775-7095 SPECIFICATION : API SL X42 PSLI/AOI us PBLI/ASTM A5S8/ASME SA538 oA[ooJH(A) MILL INSPECTION CERTIFICATE EN10204 TYPE 3.1 -1981 >1 : A&R TRADING CO.. LTD. CUSTOMER HYilllc1wMI t CH Mol:L-331*-1111 M A HVSW HYUNDAI HYSCO MAI -Wil Gd9QIA1 rt;I f/K6 2051513 883-040 (ULSAN PLANT) : 1265 YUMPO-GONG, BUK-KU. ULSAN.KOREA TEL:82-52-280-014.FAX:82-52-287-8816 M6)MWgh MiM Mai 811119 28-819A 137-904 (SEOUL OFFICE) . 28-8. JAMWON-DONG. 9EOCN0-KU. SEOUL 137-804, KOREA 40X19 TEL:52-2-2112-8114.FAX:82-2-775-7095 HYS -SWI - 631 - 1 - OLT "I"11 C6A19 TENS.EBTEST !14413(x) IMPACT TUT COATu81rf. 40X19 (Gqe Lordo : 21NCH) CHIDUCM. COMPOSMON (C) TEST TYPE rP4 t6of FWORO- STATIO TER R£ 0DIP {1rr, times 21 OFC 96 x *X 116 OtLW - AMISS *11Vs GIMILE T31 W tl N T SIGH@4141 R EW O (OUTOM x THICK xU860THII MEAT NQ Y�STAFNOTH 0 III Mn A i Cu M Cr Mo Y T ND 8 N CFiO LNC TESTAAKETAWOTHGL KNo as COAT PSI NS 0 W wt a2 INS 714 (PM) Om) as MPa % a8 x100 x1000 xloo x10000 x1000 MV JOULE Ti War ix ■a ES SE NB b-E/a' X O,SW X 4:000' 826 1:8.474 200 5 UOI1S L 915 490 35 8 1 75 14 S 2 1 1 1 TA TR TR ITS TOTAL-- 325 11!174 i NWT VISUAL! FLATiENW. SRA. R19 A-FLAT7ENR10 R14 "WO Rib NONONTRUOTNS rw 918 RMT !IT CRl9M TE8T Btlb ORIFTTpT ■19 N.AtafE TEST 7116 all TRWTMW DIMENSION TEST 612 Gum= 8ENO TEST TEAT TEST (U.r) GooD 0000 0000 GOOD 0000 ,,,. . mm. rnnea inns+ a6 uLono*x*w 12f5so. TTrwwm" 9RRQ 117 Ww" mom 2A*. W:twld Fut Yale aw w also I TCTrwow Cocaft as IIOlalno Tiro RAAI2) sa: a Anmiewld4N-- 470 A rairYrs aS ICHii1(NOb)PAN"m 60341.P:Pre&AtAasbv%X44016. WP:W41d Pro&ct Andali 66le A41114 as CE0�0•Mnm+tm+o+)/15+(OrrMWN)/S 9210:ho i a IO:Pbet rratrn*M 6AFJ a 11 maw a ONmwwbn Tea 4219 21taAl A 12 FW&nindMnOfGWCW Bind Test 86/85/89 A19 Tntow +a 16 wwwo Test HIM3 MAI 13:Paw. Ftasiniro Test !714:1 w t4 HwirO rat s1fN a rles a n EMERW sed Biwl W4 :Ei1W TETMId End •844 a f a:IwaMval Mepnslkrr Tait 8RA6A19 a 17:CAWn Test 6$AI6 w MOM TOM 66A141 t11s:Fbrw Testa9AA)a NO C YW - AN 26WASYM 901WASAIR2007 v1#8 66 t'421al 9492,60 26940. WE HEREBY CERTIFY THAT MATEBML OSSCMSED HERW NAE SEEN ACCEPTEO W ACCORDANCE WITH THE PREsCF3S® SPECIFICATION AND OROER • 6 aAra9At9 671E ,hiss Af6At va41 3XA Y61Y 4 t2a WA166AI 9I.IR—I!u3Al Oils 54X fiat' 4 2115 U0 INSPECTION MANAGEA SURVEYOR A4(210x297) HYS -SWI - 631 - 1 - OLT "I"11 0 0 0 N0 HEAT -NO TYPE Skil OD W.T LENGTH TS YS EL YR WTS pry C SI Mn P S Cu Ni Q Mo V N6 Ti inch inch ft D3 PSI % % -2 3 -4 PCS '1 '2 >�R/ft '3 •4 PSI g •6 01 M72179 38 EPEE 8.625 8.625 OSOO 42 19XA H 6 1 77 12 5 VA* pub INSPECTION CERTIFICATE P/0 No. 404411 OMB L/C No. T h CERTIFICATE No. : 130930-A645 ISSUED DATE : 2013.09.30 sn H U 5 T E E L COar Ltd. MANUFACTURED ND. -o -0 8 i3 6 1 HEAD OFFICE : SHINAN 8/D 15F %33-19, DAECHI-DONG KANGNAM-GU, 12 COMMODITY : E.R.W. STEEL PIPE SEOUL, KOREA SUPPLIER Soon-HongTrad(nf Co.. Ltd. Q AN 5L X-42 PSL1/API 5LB DANGJIN PLANT 13L BUGOKGONGDAN STREET, SONGAK-EUP, 11 SPEC071CATION /ASTM AS311/ASME SA 5311 DANGfIN-S1, CHUNGCHEONGNAM-D0, KOREA CUSTOMER = R&R Trading Ca, Ltd. QWUF TRY NOWNAL ORDERSIZE wow THNSOFTEST CHEMICAL COMPOSITION(*) N0 HEAT -NO TYPE Skil OD W.T LENGTH TS YS EL YR WTS pry C SI Mn P S Cu Ni Q Mo V N6 Ti inch inch ft D3 PSI % % -2 3 -4 PCS '1 '2 >�R/ft '3 •4 PSI g •6 01 M72179 38 EPEE 8.625 8.625 OSOO 42 19XA H 6 1 77 12 5 1011 30001 5 1 GOOD I 900 1 021 16601 5 1 GOOD 1 900 N •1, adFlpelods 0 T E I I I I I I I I Latest edition per API 5L(45,2013)ASTM (20121ASM E[2022) • 2. O.D : OubW DWMw, W.T : Wg)7bidmas •3. Dlmcft L : bo jdtlYrL T : Tearvaw ceaa.—d na,e tae, • 4. Te mBs Tag •78 : Tawk Scmaph. YS : WOM Smigth. YR : VIM Raft EL i Bbapdom WTS : W.M ensile aumgtA Owp Lag* :2 tart. Y.P mnead : 0.5%Oadwked an se.e- • L N : Nmwmok P : Pra"n a::alyah ' L .2 ::[1/100,,1 :4/1000, i : x1/10000.5: x3/10000. Tr :Treta '7. H : JIM Metal. eet . W : WWO Um 6 : HAOYmed Zana ie'ee0id G7�btab •& $Pod==Sin -&A0x10ma,B:lWSma►C:IDx6A=% D:1MdAma:. DtrwdmLou07todiad '0.T.P:7=dnPnssum N.T:HoWngTIm •1&"mTreaftwo SbrmNemeaRai, Wsehee TbmdedIlOea►lw •II.WZC:We*to/21ar Coatln0,aT :Copper SGlpbm Taat •IL TPI: firodspertack CM:&hed"n:Rtt:Gfftade •IL NOT: Ur Or ECT WEHERY84CER.ITYTHATTHBMATERIALHEREINHASBEENMADEANDTESTEDINACCOROANCEWITHTHEORDERANDABOVESPECIFICAMON � d)• THIS CERTIPI(ATE IS LSSUEDACCORDING TO EN 10204 3.1(ISO 10474 3.18) MANAGER OF QA TEAM RPB VA* pub OPS BPR OKee"W OMB an T 68,020 55,112 35 81 72,226 P 6 1 78 12 6 25 11 21 Q 16 230 11 P 6 1 77 12 6 25 12 21 42 17 231 10 02 M82991 98 JIM 10.75 10.750 0250 40 12.72 H 7 2 79 13 3 T 66,134 53,952 37 82 70,340 P 7 2 80 13 5 2S 9 28 37 14 120 7 P B 1 2 80 13 S 25 10 28 39 15 123 8 HYDROSTATIC TEST HU, ZINC THREADS HARDNESS IMPACT TEST •13 N • D • T PLATTENWGOR VISUALA METALLOGRAPHIC RESIDUAL TREATMENT COATING TROT TEST ( UT or ECT) BWDTWT DIMENSION TEST MAGNEYiSM H0. TP H.?RESULT ( 0 )-c WZC CST E11 GOOD GOOD GOOD GOOD GOOD TPI Psi we T Ejn' TIMES mm DIV E -V FLANGE REVERSE CRUSH 09 •10 -17 -12 KV •7 (1114 1) 49 TEST FLKMNINGTESr TEST 1011 30001 5 1 GOOD I 900 1 021 16601 5 1 GOOD 1 900 N •1, adFlpelods 0 T E I I I I I I I I Latest edition per API 5L(45,2013)ASTM (20121ASM E[2022) • 2. O.D : OubW DWMw, W.T : Wg)7bidmas •3. Dlmcft L : bo jdtlYrL T : Tearvaw ceaa.—d na,e tae, • 4. Te mBs Tag •78 : Tawk Scmaph. YS : WOM Smigth. YR : VIM Raft EL i Bbapdom WTS : W.M ensile aumgtA Owp Lag* :2 tart. Y.P mnead : 0.5%Oadwked an se.e- • L N : Nmwmok P : Pra"n a::alyah ' L .2 ::[1/100,,1 :4/1000, i : x1/10000.5: x3/10000. Tr :Treta '7. H : JIM Metal. eet . W : WWO Um 6 : HAOYmed Zana ie'ee0id G7�btab •& $Pod==Sin -&A0x10ma,B:lWSma►C:IDx6A=% D:1MdAma:. DtrwdmLou07todiad '0.T.P:7=dnPnssum N.T:HoWngTIm •1&"mTreaftwo SbrmNemeaRai, Wsehee TbmdedIlOea►lw •II.WZC:We*to/21ar Coatln0,aT :Copper SGlpbm Taat •IL TPI: firodspertack CM:&hed"n:Rtt:Gfftade •IL NOT: Ur Or ECT WEHERY84CER.ITYTHATTHBMATERIALHEREINHASBEENMADEANDTESTEDINACCOROANCEWITHTHEORDERANDABOVESPECIFICAMON � d)• THIS CERTIPI(ATE IS LSSUEDACCORDING TO EN 10204 3.1(ISO 10474 3.18) MANAGER OF QA TEAM RPB VA* pub OPS BPR OKee"W OMB an areeThnodwawr ars BTC MuNftemw OOaged OTC G HMC C-30,06-(21) 81 &JAH"Ai0A 19718 ijzl" 21 AW14Fa# &i l OW + 21PA. WA}$8AJ 91 • IJ -*A1 AWAI VV11{8231JE1JIL 101941 JISW T 21111.14. PAGE : 1 / 1 0 0 0 P/0 No. 404411 L/C No. ISSUED DATE 2013.09.30 COMMODITY : E.R.W. STEEL PIPE API 5L X-42 PSL1/API SLB SPECIFICATION : /ASTM A53B/ASME SA 5311 QowN. NOWNAL 01 NO 7 INSPECTION CERTIFICATE HUSTEEL Co.,Ltd. HEAD OFFICE : SHINAN B/D 15F, 943-19, DAECHI-DONG, KANGNAM-OU, SEOUL, KOREA DANGIIN PLANT 131, BUGOKGONGDAN STREET, SONGAK-EUP, DANGIINS7, CHUNGCH60NGNAM-DO, KOREA CERTIFICATE No. : 130930-A645 MANUFACTURED No. 13-08-013 SUPPLIER Soon -Hone Trading Co., Ltd. CUSTOMER : R&R Trading Co., Ltd 1 021 16601 51 GOOD 1 900 N •1.TYpe of Pipe Ends 0 BPH tlrtPOin T E I I I I I Latest edidon per API 5L(45,2013) ASTM(2012) ASME(2012) - t MD : Ounid Diummr, W.T : Weil Thickness -3. Dnecear L :londOtlNr1. T:Tra rom W -m. d run tans -4. TomAe Tiet •73 : Ttwlie Stria^ YS : YWd Strengti. YR : Yield Raft IL: trloopftL WTS : Weld srne0e snenedn OmW Lagift : 2 {os3, Y.Prb*dW : 0.546 Undsriaod Ort ewNhd • s. H : Heetw4sls. P : Product amlysk • a s : x1/10o, 3 : at/1000, i : x7/10000,5 : x1/10000.7r :7tser • 7. B : Dasa Halal, W : Weld Line. R : MMABeemd Zoog Gstvmed TL-m"We •H. SIR , I flre,4:rOs30mm, 8:100Smm. CA046dun, D:10xS.Omn% Okacfta Loogleulmsl '9 LP : TatluH frssson, N.T: HeldftTime -10. SWTresmwOdq nent Seen Nor 6Wnusd Tg,od"C.40 I • )I.WZC : V/Wmo(Vw Coxiv& CST : Copier SLlrhsk l►st • IL TM : Thrwds Pa lnrh, M : W twdve lona of tbeeds - 33. NOT : LIT Or Wr, WE HERYI3Y CERTIFY THAT THE MATERIAL HEREIN HAS BEEN MADE AND TESTED IN ACCORDANCE WITH THE ORDER AND ABOVE SPHCllnCATION 74V THIS CERTIFICATE IS L%UFD ACCORD WG TO EN 10204 3.1(IS010474 3.18) MANAGER OF Q.A TEAM HEAl_nu H ZINC s� OA w.T t. m -m IMPACTTBSC `13 N • D - T TS YS EL YR NRS DIV t Sf No P S Cu Ni Cr Mo V Nb Ti s1C ATiKI NGTBST k PCS Inch inch R w h -S �13111 PSI 76 % PIR -2 .3 -4 -r -Z .4 '6 Zt � ETL GOOD GOOD GOOD GOOD 01 117Z174 38 BPBB 6.625 8.625 0.500 42 19.68 Eneryr 5128 PLANGE REVERSE CRASH H 6 1 77 12 5 NV -71 andf) TEST PLATTENINGTEST TEST 01 3000 TS GOOD 900 T 68,020 55,112 35 81 72,226 P 6 1 78 12 6 25 11 21 42 16 230 11 P 6 1 77 12 6 25 12 21 42 17 231 10 02 M82991 98 BPEB 10.75 10.750 0.250 40 12.72 H 7 2 79 13 3 T 66,134 53,952 37 82 70,340 P 7 2 80 13 S 25 9 28 37 14 120 7 P B 2 80 13 5 25 10 28 39 15 123 8 1 021 16601 51 GOOD 1 900 N •1.TYpe of Pipe Ends 0 BPH tlrtPOin T E I I I I I Latest edidon per API 5L(45,2013) ASTM(2012) ASME(2012) - t MD : Ounid Diummr, W.T : Weil Thickness -3. Dnecear L :londOtlNr1. T:Tra rom W -m. d run tans -4. TomAe Tiet •73 : Ttwlie Stria^ YS : YWd Strengti. YR : Yield Raft IL: trloopftL WTS : Weld srne0e snenedn OmW Lagift : 2 {os3, Y.Prb*dW : 0.546 Undsriaod Ort ewNhd • s. H : Heetw4sls. P : Product amlysk • a s : x1/10o, 3 : at/1000, i : x7/10000,5 : x1/10000.7r :7tser • 7. B : Dasa Halal, W : Weld Line. R : MMABeemd Zoog Gstvmed TL-m"We •H. SIR , I flre,4:rOs30mm, 8:100Smm. CA046dun, D:10xS.Omn% Okacfta Loogleulmsl '9 LP : TatluH frssson, N.T: HeldftTime -10. SWTresmwOdq nent Seen Nor 6Wnusd Tg,od"C.40 I • )I.WZC : V/Wmo(Vw Coxiv& CST : Copier SLlrhsk l►st • IL TM : Thrwds Pa lnrh, M : W twdve lona of tbeeds - 33. NOT : LIT Or Wr, WE HERYI3Y CERTIFY THAT THE MATERIAL HEREIN HAS BEEN MADE AND TESTED IN ACCORDANCE WITH THE ORDER AND ABOVE SPHCllnCATION 74V THIS CERTIFICATE IS L%UFD ACCORD WG TO EN 10204 3.1(IS010474 3.18) MANAGER OF Q.A TEAM MMADSTATICTSIT H ZINC THREADS erese..er IMPACTTBSC `13 N • D - T FLATTENBIGOR VISUAL& NBl'ALLOGRAPHIC RESIDUAL s1C ATiKI NGTBST k art ( UT Or1Cr) BENDTEST DIMENSION TEST MAGNnV4 'T.PH.TTREATMENTTdST(0)1rGOOD Zt � ETL GOOD GOOD GOOD GOOD RESULT TPI PSI Hoc 7r m' TIMES mm DIV Eneryr 5128 PLANGE REVERSE CRASH 19 '10 -21 Z2 NV -71 andf) TEST PLATTENINGTEST TEST 01 3000 TS GOOD 900 1 021 16601 51 GOOD 1 900 N •1.TYpe of Pipe Ends 0 BPH tlrtPOin T E I I I I I Latest edidon per API 5L(45,2013) ASTM(2012) ASME(2012) - t MD : Ounid Diummr, W.T : Weil Thickness -3. Dnecear L :londOtlNr1. T:Tra rom W -m. d run tans -4. TomAe Tiet •73 : Ttwlie Stria^ YS : YWd Strengti. YR : Yield Raft IL: trloopftL WTS : Weld srne0e snenedn OmW Lagift : 2 {os3, Y.Prb*dW : 0.546 Undsriaod Ort ewNhd • s. H : Heetw4sls. P : Product amlysk • a s : x1/10o, 3 : at/1000, i : x7/10000,5 : x1/10000.7r :7tser • 7. B : Dasa Halal, W : Weld Line. R : MMABeemd Zoog Gstvmed TL-m"We •H. SIR , I flre,4:rOs30mm, 8:100Smm. CA046dun, D:10xS.Omn% Okacfta Loogleulmsl '9 LP : TatluH frssson, N.T: HeldftTime -10. SWTresmwOdq nent Seen Nor 6Wnusd Tg,od"C.40 I • )I.WZC : V/Wmo(Vw Coxiv& CST : Copier SLlrhsk l►st • IL TM : Thrwds Pa lnrh, M : W twdve lona of tbeeds - 33. NOT : LIT Or Wr, WE HERYI3Y CERTIFY THAT THE MATERIAL HEREIN HAS BEEN MADE AND TESTED IN ACCORDANCE WITH THE ORDER AND ABOVE SPHCllnCATION 74V THIS CERTIFICATE IS L%UFD ACCORD WG TO EN 10204 3.1(IS010474 3.18) MANAGER OF Q.A TEAM HMC C-30.05-(21) $ MAWjAi0191718 ,iZ1$5e 21 AAAI 2MV NWI *dW 4-11". i1AHIFNAi 91.9WI Ak*Ai WaE(90231MA *01442 R1l1414# 241-14. PAGE 1 / 1 4 0 tl':.i S e t is I. e.4 GTL eMs erese..er ares 117E ut<rsr..d.a Saar 6171 s1C sndnlrwM eo.gendI art HMC C-30.05-(21) $ MAWjAi0191718 ,iZ1$5e 21 AAAI 2MV NWI *dW 4-11". i1AHIFNAi 91.9WI Ak*Ai WaE(90231MA *01442 R1l1414# 241-14. PAGE 1 / 1 4 0 tl':.i S e t is I. 0 0 0 g81M ,s I9OIXI CERTIFICATE NO. : 2800747 PAGE 1 of I LATE OF ISSUE. : 2DI2-11-08 7641.132 IMPACT TEST OONTRACT(PJO) NO.: 403890 200092474 is COMMODITY : M.F.W. 36f Tial 4JMM SPECIFICATION : AN SL 60.9 PSLiM3TM ASWASME SAi36 o A} o o kl {A) MILL INSPECTION CERTIFICATE EN10204 TM V -1661 $ : RBR TRAD" CO.. LTD. CUSTOMER MvurwM 2!1II8k01:����'�ll�k HYUNDAI HYSCO IN1At-i$ fNBefM 61-7 gsi2658A M -M (ULSAN PLANT) : •265 YUMPO-DON(3, BUK-KU. ULSAN,XOREA TEL:62-52-260-014.FAX:82-52-267-8916 A12144& MIKA3 A(i4 88626-61VA 137-904 (SEOUL OFFICE) .29-5. JAMWON-GONG, SEOCHO-KU, SEOUL 137-904, KOREA TF -L:82 -2-21!Z-9114. FAX:62-2-775-7095 HYS - B3D1 - 631 -1 - OLT 7lTLM4L*Y nT,-A.,U b a19A1M TENSILE TEST 91oMW%)1141AIM IMPACT TEST it1AIN 00ATIN0 4JMM (baps LM091: 2 INCH) CHEMICAL COLIPOSRION ( t) TOT 219 Y4 �� C as OF PtFe DIMENSIOPE N 239 K rru X 3f01 Q+UA19N QUAN 944 WEIGHT TEST Baas a$iHs TENSILE a tl ,URO AWA a e .11 29a dim ENO 8]tJTDu X THICK x LENOITMI -TITYMars HEAT NO. ySU0 STRHMTH ><' C 31 Mn P S Cv M Cr Mo V Ti Ns 9 Al CEO Ness 81tEM APX S. MOTH !BO AREA OWEIGHT F ZINC TDIP at Y7 !7 !L 191MI4Y COAT P8t 15 8 M (pC8) (ItG1 06 we % So -100 -1000 x100 X10000 X1000 HV JOULE % 0// A16E DIES !1 02 A3 !4 ON N9 6-619' X 0.600' X 40.M' 26 22,064 2470 5 MN079 T 3T2 506 626 36 6 1 79 13 5 2 1 I 1 TR TR TR ON NO I2-3/4' X 0.276' X 40.000' 21 t9A66 1250 5 MUM T 383 513 50 44 6 v T7 14 S 2 1 1 1 TR TR TR 45 40,410 12550 5 s6896D6 T 366 519 553 41 6 1 74 IS 6 2 1 1 TR TR TR 21 16.668 1250 5 MUM T 360 405 516 41 5 1 76 12 9 2 1 1 1 TR TR TR asof NB IIr X0.375 XM.OW 71 MAN t000 S SMIS6 T 346 SM 542 37 IS 2 79 14 5 2 1 1 1 TR TR TR 39 44.210 1000 8 3=191 T 731 426 521 41 19 1 70 14 7 2 1 1 1 7111 TR TR TOTAL 286966 7110 NEAT all VISUAL a 612 FIATENOIG. Sm. !t3 R-PIATTENINO ! la FLARWG 1515 NONOE8TIIUCTNE TEM all R.M.T At? CRUSH TM 019 DIBFT TEST 1519 FLANGE TEST TREATMENT DIMENSION TEST GUIOED BEND TEST TEM TEST (U.T) I 4000 0000 WOO 0000 000D loll W n eOD*>Mufties M3 I'M 'am -w4 • W. BYCA No: sAw Boo TC e fees CM !9 Mddn9 Time *MAI a S" a A UL"4 tuWal NOW W. T:Tfsnswns M* W9 07 9:61144 MELT RM W. W1N4M Pett 994 SO W*1641(LSON) Ansys6 96141. Y•Pmtlun Ansyais M19944, WF:WOM Roduct M*sb ONE 7941544 09 Ca'iKOSMnIMcNhCM1n5KOr+Lb`b/8 G7)eie MAW 10:1490Ina om ISAM All VNusl a DismMlHos Ton Re! 9 .34914, 1512 PARWW OOMWOu10 d OW4 Test 99/82111MAI9 NO TN -w Pg~ SMAI`! 14 711dn0 Test VIIAIM 015 N4ndnwcan Teat 51999A1 0 U:Rwsna PIeRmft Test a31A1 M :SMI StYl;; T Thea End 601641EnE •19:Residesl MSTlsttfm Test AAABAIM 01T.Ct-011 Test 19MMM 019:Or0t Test B946 f19:P0rp Test talus NO I - APi 26MASTM 20 0 ' 9 7499 at a4NDI 21851$9; i192;4D. WE HEREBY CERTIFY THAT MATERt4L 093ORMED HEREIN HAS BEEN ACCEPT90 IN ACCORDANCE VAT" THE PROSCAM SPOWICAT-DN ANO ORDER • 9 9M99M6t 9716 ,7419551 ARM 11aa EMIX 9119 4 11401. 11A1199M 41.93Al A19M 41112 110011151811; 4 116LIU. SURVEYOR 9S►ECTION MANA6PA HYS - B3D1 - 631 -1 - OLT 7lTLM4L*Y nT,-A.,U b • • • INSPECTION CERTIFICATE P/ONo. : 404411 CERTIFICATE Na :140106-A26 L/C No. W 4��� � �+ � 1, ISSUED DATE 2014.01.06 :. H U S T I t L `Ay Ltda MANUFACTURED No. ° 13-08-013 HEAD OFFICE : SHINAN B/D ISF, 943-19, DAECHI-DONG, KANGNAM-GU, SUPPLIER Soon -Hong 1Yadim Co.. Ltd. COMMODITY E.R.W. STEEL PIPE SEOUL, KOREA API 5L X-42 PSL1/SLB DANG)IN PLANT 131, BUGOKGONGDAN STREET, SONGAK-EUP, SPECIFICATION /ASTM A53B/ASME SA 53B DANG)IN-SL CHUNGCHEONGNAM-DO, KOREA CUSTOMER R&R 7Yadinx co„ ltd. QLlAN. NOIDNAL ORDERSIZE Waw TBNSDBTEST CHEMICALCOMPOSTTION(SS) 0.0 W,T ILMGTH DIF IS YS EL YR WTS DIV C SI Mn P S Cu N3 Cr Mo V Nb Tl B CBQ PCM NO. HEAT TAT TYPE -NO Sn inch Inch R PSI % % .2 -3 4-5 -3 PCS "1 '2 )W/ft PSI '3 V 45 '6 01 M82812 25 EPEE 8.625 8.625 0.500 42 19AS H 6 1 77 14 6 15 10 20 TR TR 240 10 T 73,386 63,814 37 67 74,401 P 6 1 77 15 7 15 30 22 14 21 239 7 P 6 1 77 14 7 1S 11 22 15 21 240 7 02 Nam 50 LIM 10.75 10.750 0.500 40 24.83 H 7 1 74 11 S 16 10 20 TR 10 240 10 T 65,699 6$799 41 96 74,401 P 7 1 75 11 7 16 11 19 12 1S 240 10 P 7 1 74 11 7 16 12 20 12 15 240 10 HYDROSIMTICTESiZINC HES. THREADS HARDNESS OdPACTTEST •13 R �N McIALTEST C Tp TREATMENT COATINGTBST I 7EST (UTOrECT) BBNDTESt DMV MAGNETISM GOOD NO. ( 0 ]L H,T WZC �I GOOD GOOD GOOD GOOD FLANGE REVERES CRUSH RESULT PSL mo T: Else I TIMES mm DIV 6ner� HV y L1ad A 'S TEST PL47'TENRIG TEST TEST 09 '30 '1112 01 3000 S GOOD 900 02 3000 5 GOOD 900 Latest 4dlldon per API 5L(45,2013) ASTM(2012) ASME(2012) N Llypomposuds • Z O.D : OntrM Dhmota, W.T : Wdl Tbfdmm 9. (Hroadow L : IaeBmd" T : Trmovan 5Pa smat Hre 0,4 Cn ndwnY�d Plan a. • 6 TbadiNYd •Tl : Tomsk lnnWa vt ; YWd swwgk YR : YMd Ra" IL - Moopdoo, WTS : Wold Week, otroxah,Omp 6oso :2 ash, YJ mothed : M UndMmd 0 T iO • i H : Rnuooy" P : Pmdoa mob • 6. 4: sl/00,.3 : x1/1000, 4 121110000.4 : s1n00, Tr a 7. a : am Mad W : Weld Us% H : HmtAOksd ?ono arse a"=. E r ! DlesdMa Transmso •1.TJ :Tbtthy Pnrwv, dT sHoldlnlThoo -10. owTrntmoat a"Normnlla4,5 BTS .Z1pmdmmlkmA:10dOmmB:10ASmmC;lftL6mmDIIOxb.0mm. tlC a,almmd•d1 all I •tLWIC:WdjhtofljwC*mh*CTT:CopWSu49Nft'mt •12.TL9:ThroodtpaNeb, 3n:lfhNwleo501offt '13.NDT:UTOrECT, Jow l2k WE HEREBY CERTIFY THAT THE MATERIA, HEREIN HAS BEEN MADE AND TESTED IN ACCORDANCE WRH THE ORDER AND ABOVE SPECIFICATION THIS CERTIFICATE M ISSUED ACCORDING TO EN 10204 3.1(15010474 3.1 B) SURVEYOR MANAGER OF QA TEAM HMC C^30a5(21) . INAHMA4 41 • Lrl>6AI A*Ai 9iiE(1IW2313E)JR *01Wi W$M 4 91*WCt- PAGE : 1 / 1 .. HUSTBEL PIPES MANUFACTURE CERTIFICATE MILL TEST CERTIFICATE(S) LIAONING LARGE-SCALE STEEL PIPE CO., LTD. ACCORDING TO THE NORM EN19200•41 1 ArlAnana• Nn 1 _9AAW11AKIA%tW11 TA171141: FLAT- 1 Faf]VANC. _ LIAANINQ_ C141MA API Rea.Noa SL -0444 Cerll N0. kYtpl31 Purchaser RSR Trading Co.. LW - Goods DMCrlpdon PRN4E ERW STEEL PIPES(peinted pipa8 32PCS) Page Issue "A 1, Standud API 514501 PSLI GR.8fASTM A S301SAM P.O. No. P06404836 1 Ake 16nOmW76irrJrs'40R I Grade a TOM Place (Pq 52 TOWmi6X1.064Lervw T0� 58.131' Pipe TelmNe Tasting f4yeroatatic NOT V1wa! 8 Piece Length Welght Y.S. T.S. E Weld T.8. Item No. Neal No. F P•6.6Mps Dimension 1-160 UT Inspection PC m mt Mpg We (%) MPa 1 /3507119 Pakdad piper17pes 207.264 18.531 300 444 45 490 A A A A 2 13007121 I Pew pipp;35M 426.720 39.799 294 442 40 487 1 A A A A Chemical Composition Nem No. C Si Mn P 8Cr No Ni Al Cu Nb TI V , 6 CE.. CEMmdW1gpaphy Heat No. Test 0.040 0.147 1 105 0.011 0.008 0.027 0.002 0.011 0.036 0.012 OA02 0.014 0 001 0.0003 _ 0103 A 1 13307118 0.045 0.150 1.104 0.011 0.006 0.032 0)002 0 011 0.035 0.012 0.002 0.014 0.001 0.0003 _ 0.108 A 0.054 0.139 1.000 0.011 0A08 0.027 0.002 COW 0.025 0.011 0.002 0.013 0.001 0.0004 _ 0.096 A 2 11307121 0.066 0.137 1.004 0.011 0.008 0.021 0.002 OA10 0.026 0.011 0,002 0.013 0.001 0.0006 _ O.O9D A NOTE T& Tensile SVsllgth : YS: Yield Strength : (D NOT: Non Destructive TesHrq: E, Elongation ; A: Aooeplable ; UT: 100%UWasork Testing on plate, weld seam, pipe and and welting IOP" POW-(03.2mta Hole); ® CEwpC+MN6+(Cr+M0+Vy5+(NI+Cu)115; ® Laboratory led" tr"uency IS aro each heat: CEp"-C+$1430+(KintQ+Cry20+N•JSO W15+Vf10+S6: ® The pipes damaged durkp VansporWW mid unloading aro not with in MO scope of CERTIFICATE: ® Tat & kupecl method accAPI SL WE HEREBY CERTIFY THAT THE MATERIAL DESCRIBED HEREIN HAS SEEN MANUFACTURED, SAMPLED, Inspector Revia+u Manager: TESTED AND INSPECTED WITH SATISFACTORY RESULTS STRICTLY IN ACCORDANCE WITH THE _ REQUIREMENTS OF ABOVE SPECIFICATIONS AND PURCHASE ORDER.THIS REPORT IS ACCORDING TO 4*4 � THE NOW EN 1020413.1 i i �f ROM7-1 �� (A) �cNstof��T,I �� "� � `=f PAGE 102 HYUNDAI HYSCO CERTIFICATE NO. 3700635 O fWjWQIA1 31 g3ef 265>'tA 6B3-Oa0 f, -am MILL I N S P E C T I O N CERTIFICATE (ULSAN PLANT) ♦2651'UMPO-DONG. Bl1K�KU, ULSAN.XOREA DwvtzATE OF ISSUE. 2013--07-08 g,1t0204T'l 3.1 -1991 TCL:82-52-280-014, FAX:82-52-2874916 73>C L' 2o0oo4os MW Alf Al Niro $15i 2B- VM 137-804 CO NTRACT(P/O) NO- : 404340 CO -411 A Al : R&R TRADING CO.. LTD (SEOUL OFFICE) . 28-6. JAMWON-DONG 137-90 4, KOREA CUSTOMER SEOCHO-KU. SEOUL FAX:82-2-775-7095 COMMODITY H.F.W. TEL:82-2-2112-9114, MORS SPECIFICATION : API xe P{l lr A{TM A430rARM0 34538 $�71M11 S QINN p3PACT TEST COATING ��� � ) ( TEST 41$N EI TENSILE TEST CHEMICAL COMPOSITION 4WNtl (Gape Lorg61:21NCH) Sri HARD a k 21 III REIA- £1! 'k4 4,11 WORD- 6TATIC 21i4><l5? 0 g El 8W91 NE63ABSOR_ 1141' WB6HT p1P A1LK TYPE DIMENSION 'JaIE TEST Q m Vill gIELD g RENGTH i N Mn P 5 Cu NI Ct Mo V Nh 8 OF DNC TEST N Cgo EO � COAT OF slim x *a x &I01 PIPE x THICK x L.E►XsT►0 HEAT NO, C HEAT (OUTDIA END STRENGTH kN h)UlE % arMS RS 8 W £.L PSI f6 % [8 x 100 x1ff00 x100 xlaw x1000 ■1 112 f3 !a (PCSI (%G1 { 6 MPe 72 11 7 2 1 1 1 TR 1R TR 158 6-518' X 0.722' X 21.000' 1ti6 50776 two S M7217d 4l7 517 348 85 7 2 T 18 8 2 1 t TR TR TR 77 ' 157 E8 BE NB %0.300' %21.000' JO 15A62 1900 S M7S138 7 a18 520 552 36 8 2 17 4 2 1 I TR TR TR 158 E8 BE /1B 10-•7/4' 2 1.086 1140 5 M66709 T 303 406 521 37 6 2 78 1 TR 1R TR 159 l6 BE NB 10X0.875'%21.000 T 382 506 537 38 6 73 1J 4 2 7 159 S 2.594 1140 S 5 2 10 7 2 1 1 1 TR TR TR 2 1,036 1140 S El T 419 328 5% 3T 1 t 1 TR TR TA 2 1SB t $19 1140 5 T 865 493 510 IS 5 1 7B f0 5 1 t S TR TR TA 156 I S19 1140 5 M73317 T 404 511 541 33 g 1 i7 12 4 T 1 1 TR TR TR 159 1 2 1.086 1740 5 MJ982D 7 361 320 550 37 g 1 76 13 6 2 1 1 1 1 TR TR TR 156 J 1.337 1140 5 M73416 7 360 466 497 36 6 1 74 t5 6 2 1 1 i TA TR TR 158 2 1.038 1140 5 M74641 T 366 ASO 523 96 6 2 74 10 S 2 t t 1 TR TR TR ISO 23 11,986 1140 5 M76819 T 374 477 511 38 5 2 79 17 a 2 2 1 1 1 TR TR TR lot EB BE NB 18• %0.375' X 42.000' 1 1.342 1000 5 IA7'3M T 409 SW 544 � 8 1 72 6 1 .� 17 7 IS q 2 1 1 1 7R TR TR 162 RIO FLANGE TEST 22 20.531 1000 5 M76864 T 394 4K NONOEBTRUCtWE TEST [t6 RMT {17 CRUSH TEST [ 18 ORIFT TEST [ 10 HEAT [ S 1 pOAEtlBVIWb 8jgJ7 FIJLTTEMNfi. BEND, 1912 auroEO 9ElA T68T FLARING [t3 It 1014 yt4 TEST ;1S W.TI GOOD GOOD 4'a+ea {a Unq M: Nr. L -w1eh Part a$'R TREATMENT 13000 0000 a M:rnrn. Qp Nr.WaN , [76Basa lAaW '�' {6L:tonDltudirmliLs"Yt1l.T:Trartaw1s441tlWlF apps 1 [1 M SILw ByCA TcTMaa{ Co0Dtln0 S Hddlnp Time RAAIi? Bat f &a* p$a41 is a4l$C, P:ProOua AnaNa h FI!}$bl. ITP w4p Pr11 ujq 7as13LP1tl {OCEO�aunrB�lNf.aU15�(G+MrV1/5;718211 ft14iI Al ml 2 F1UA s/w 9arxl Taal matil /$OM tl 'ERw BIKIt Cl— w tt>q [BH:FNaItlLadla)AnaNsis [11 VItw16DNmandon osl & l tr 0ft Tel' {1514endnlnK6VeTn1tl118i1tlN • O: Hatt Treatme+4 tl 1321 [ 14 Flarin0 Test W OAItl {19:FlanpeTastlFBANtl ~kT EC•' eTnraea C' + .Ptah 913:RwarsaFlatt4nin0Taa1a3'"N {tv.0oftTelRDA-18' ry V17:Crush79SI1PVNV MaOnafislnTat _RA31Mtl m4 mad stfok" End 4 •t6:ReWtlaat tf� tZi_41. k7i % :ERwOttvana�+0 NO 2 • MACE M 1. HARONE7S ONLY) f�. x(eft + -ae PAM tl2till S:atluT}. mb,e -w ACCORDANCE PATH THE PRESCRIBED SPECIFICATION AND ORDER iN r°7411u 1145PECTIOII LwIAG4ER RiAI DESCA!BED HEREIN I BEEN ACCEPTED ¢1 THAT MAT_4 ?d �tARtlW,r,wr11'J ss rl PLxi SOI q.,i's .41 WEr.EREBY GERtIFV • >1 ':.ti>r 91M4 gt>I�.' ;r ;Tis -i'! A4(2/0 %297) SURVEYOR HYS - 8'3C1 - b37 - t -GILT Qv! -v%~ HYUNDAI HYS00 E-Al.rrI CERTIFICATE ND. : 3700635 NVIII'm NIOIZI PAGE 2 of 2 v �• , ` 0 0 A (A) OAT' cw MOVE. : 20t S -OT -OS >wem MILL INSPECTION CERTIFICATE OMPACT(P/O) NO.: 404340 2000"m EN10204 TYPE 8.1 -1901 ars COMMODITY M.F.W. 2 211 Al CUSTOMER ' RBA TRADM CO.. LTD HID-Ri! SPECIFICATION = API 5L6 PSL1 / ASTM AWWASNE SASH " I .WAMIL I-WCHOf01.1*-m f W' w #A -v%~ HYUNDAI HYS00 E-Al.rrI tdglgAl *F7 249 265E+70 663-040 (ULSAN PLANT) =14265 YUMPO-DONO. 9UK-KU. ULSAN.KOREA NNAIWTEPSILETEST TE:82-52-260-014, FAX-62-52-297-E91E IdSAI$2 A($AI Al& -';I (kGrs! 26-6!$)0 137-904 (SEOUL OFFICE) . 28-6. JAMWON-SONG, SEOCHO-KU. SEOUL 137-904. KOREA TEL:82-2-2112-9114.FAX:82-2-775-7095 HYS - 8301 -631 -1 - OLT HYUNM HY(S'CO A4(21Cx297) NNAIWTEPSILETEST Net"M WN)JIf £9tmtj 4#NII (taupe Lw4lh : 2 INCH) CHEtlCAL CCNP081110N IMPACT TWT COATRG ItsHYDRO- ( L) TEST CPE 3t4 DMENSION OW 8T1EST #£ HARD 41 PIPE 91# x t*8� x i1q OQiNf _ TITYVTEkIF1T Aii!>«4 Niil£d OI 4 $ E 0141 W2 EIA (OIRDIA x THICK x LENOTW HEAT NO. YIELD Fv # C $I Nn P S Cu 4 d mo v 71 Ne 8 AI CEO NEW AB M H�# 61 � W#6;CiNiT OF 200 TEST ARK STRENGTH!0B� ENERGY GOAT iSEL (PCO) (1001 !® NPa % !0 x100 x1000 x100 x10000 x1000 HV .IO%AX it !E 08 i4 51 00.459 1000 5 MNNN T 808 407 $21 39 S 1 75 13 5 2 1 1 1 TR TR TR 101 TOTAL — 381 107.007 MOAT VISUAL& ! /0 TREATMENT ! 11 DINN TEST FLATTEMENOIOWG. BEND. wit GUIDED SEND TEST R -FLATTENING ! 1 s TEST FURING X14 TEST NONDESTRUCTIVE TWT 11113 IU.T) W16 R.M.T i 17 CRUSH TEST ! 10 DRIFT TWT Sit FLANGE TEST 0000 OOOD 00000000 GOOD De t Beeler 93 UNI :mm khC i t 'ERW EnoI AWSAW BIM TC..m"w Coupmo IS FIoW Time R31A121 Set N i0 L'Lor*kLd W 9t410N. T:TMWVK a 8*0* t7 at -Bess mew.24*. W:wow Part ##* EA:ERW Mmsav W Ge WAft FIMP41 S ICltMWAd4) AnaWb 414)44(. PPtedutt Aft"r< RAMA, WP:Wetd Product M*M #N4a AI#441 1119 CLO-0+WJS+(NI�Cu1//5+(Cr+Me+V )1S g2f%I&N vetwom um" EC:ERWBAdt Tlxead PE. P4h T77d PCP%h End + IO:H@wLTmlmsnt MAIN Al l l vNual d OMmnabn Tost>A4) 91 X#VA1 IN 12 Flltonbv18wKVMkW Band Tµt OfISS/R#NW IW:Eft Qospniti i Thread BE= End pB:pWA End ♦ ! 1,1: Resetµ FlstgMnp Test 11)JAI W i 14 Raft Tqw W#AI N 115 MendeeUucOm Tei III N At NAI N ERW GiAwVsetO SWIokii tp I TE=Thread End 80:Bes Ehd ! lo.'Rw tW Ms9nettrm Test OXXIVAIW 11117:CnAh Test SWAIN 01SOrv1 Test $fAIW 919:FWLpe Test ONZAIW NOTE 2 MACE MR0175(KM"ES0 ONLY) .% f�r 14 A8# its RUN CelfrlYi$# 7.1101.10'" ^'x . WE HEREBY CERTIFY THAT NATERAL DEIICR19E0 HEREIN WAS BEEN ACCEPTED iN ACCOROANCE WITN THE PRESCR10E0 8KCIFCATION AND ORDER • 9 &MOWM01 $718 s719Ni91 AIVA1 91158 4 971 Woo �? 21201 DAIROM e1 8%N NOM *lig 4 NO X 9001 v VOLIU 3UR'lEYOR INOPECTK)N MAUA6ER HYS - 8301 -631 -1 - OLT HYUNM HY(S'CO A4(21Cx297) • • • PIPES MANUFACTURE CERTIFICATE MILL TEST REPORTS`' i LIAONING LARGE SCALEss•STEEL PIPE CO. LTD, ACCORDING TO THE NORM 1 J� Addre: NOA JIA8HUANG, TAIZHIHE DISTRICT!UAOYANG CITY, LIAONING PROVINCE, PR CHINA API Reg.Nor SL -0444 :L i Purchaser R AND R TRADING CO.,LTD..r Goofs Description PROM ERW STEEL PIPES 1 R AND R TRADING CO.,LTD. Pepe 1 +' T Standard API SUI/ASTM A 63111 A M loom Delo ` APR 2 •S0.14! 055 P.O. No. P00401 She 16.00NW4.S7SINCF�21 Wed. a TOW M ei Total 637 Tatal weiawm PIP6 TemOeTas" NDT Vismli Piece Length Weight Y.S. T.S. E Weld T.S. Rem No. Hest No. FbftnhV P4.4ups Di nension CT Inspection m mt MPs we t%) we 1 1m7t16s84 637. 50.145: 2N 426 48 478 315 476 46 464 A A A A 2 7 A A A A Chemical Composition am I& C a a P S Cr Mo I Ni I AI I Cuj NbTI V a CE.CE" metallography Hat No. % x % % x x x x % x x Teat 1 12801640 0.176 0.064 0.202 0.012 0.006 0.07s 0.002 0.010 0.026 0.003 0.001 0.001 0.001 0.0002 0.226 _ A 2 /26D1650 0.166 0.082 0.201 0,015 1 0.000 0.076 0.002 0.017 1 0.057 0007 0.001 0.002 0.001 0.0002 0.221 A NOTE TS: Tamps St wig ; YS: YIW Strength ; ® NDT: Non Duuuc&o Testing: Es Ebngstion ; A Acceptable; UT: JW%U ttasonie Testing on plate. weld seam. pipe and and waldkv repaired posidon(403.2mm Hole); ® CEwK-mm S+(Cr+Mo►yyb+(NI+Cay15; ® Lebens" testing frequency is one each Mak CES•C+SV30+Nn+Cu+Cty20+NJE0+NWt75+W10+38; ® The plpes daeraged durtV transportation and unkmding are not with In IM scope 0f CERTIFICATE; ® Tut & Inspect method sw-4PI SL(2007) WE HEREBY CERTIFY THAT THE MATERIAL DESCRIBED HEREIN HAS BEEN MANUFACTURED, SAMPLED, Inspector: Revlaw: Matalger: TESTED AND INSPECTED WITH SATISFACTORY RESULTS STRICTLY IN ACCORDANCE WITH THE REQUIREMENTS OF ABOVE SPECIFICATIONS AND PURCHASE ORDER.THIS REPORT IS ACCORDING TO THE ` � `•(ftf ,GGt�l NORM EN 10200.1 va'�J m • • • PIPES MANUFACTURE CERTIFICATE,? MILL TEST CERTIFICATE(S) ' R LWONINO LARGE-SCALE STEEL PIPE CO., LTD. ACCORDING TO THE NORM it, Address: NO.1 JIABHUAWISHU TAIMME DIdT: LIAOYANG . LWONINQ CHINA API lma.Nc. 51,43444 Purdmmw MR Th dlnp Ca, Lid 0006 D"Ovdarr PRIME ERIN STEEL PIPES Paps 'z !aw MN +° SEP, 28TH, 2018 SCsWNd API SL B/ASTM A 698/8A, 896 PA. NO PO/ 054 $1. 20 "0.376 ' %ft Grads a ToW PIM (pe) 224 L.T� �y � Tool 326 634 am H0. Hat No. PIM 740060 Too" fldMrrinp PP 2111ps wft NDT chrownim UTImellmown VIwU i PNM Lsaptl► Vftht Y.S. T.R. E Mhld T,6. m nd MPS MPS <%> MPO 1 %%4268 226 2,779.776 326.638 204 437 34 818 A A A A 2 16!0/617 266 418 46 400 A A A A 3 16111OA/6 270 418 46 SO A A A A Chwolcal Composhlon INm N0. Had No. C St Nhr P i 4Y Mo M Al Cu Nb -n I Y 4a OEM CFyCy y % % % % % % % % % % % % % % % % Tee 1 13A114266 0.150 0.001 0.284 0.000 0.007 0.016 0.002 0.010 M027 0.007 0.061 01001 0.001 DAM 0203 _ A 0.184 0.082 0.280 0.010 0A0 0.016 0,002 O.MO 0.027 OA0 OAM MOW 0.001 0.0002 0.207 _ A 2 13SUM7 0.164 OAa 0.304 0A10 0A0 0.016 0.02 0.010 0.= 0A09 0A01 OA01 0.001 0.0002 0.210 _ A 0,139 0.002 1 0.806 1 0.009 0A0 1 0.010 1 0.002 1 0.010 1 0.022 1 OA0 I 11.001 0.001 0.001 0.0002 0.194 A 3 138D4618 0.144 0.04 0.901 0.010 0.006 0.0%6 0-002 0.010 0026 0000 0001 0.001 0.001 0.0002 0.10 _ A CAW 0.063 1 0200 0.000 0.003 I 0A16 1 0.002 1 OA10 1 0.024 0.006 I 00-01 0.001 1 0.001 0.0002 0.191 A NOTE: TS: Torok Strerlpth ; YS: YIW Strength E, Ekmgatbn ; A: Acceptable; .®CE,y,-C+MMB+(Cr+NO+V)05+(NHCuy16, CEp=.C+SV30+(Nn+Cu+COaO+MW+MoM5+VJ10+36; ® Test i Inspect medwd acaMl 5L(2W7) QD NOT' Nan Deawi&ve Tesmrp; UT:100%Ukmonic Testlnp on plate. weld warn, pipe end and welding repalred posW**&2rm1 HOW; ® Laboratory lestkq *oquwwy is orm each hat; ® The pipes d9meped duMp lrensportoWn and unloadGg an not with In the scope of CERTFICATE; HEREBY CERTIFYTHAT THE MATERIAL DESCRIBED HEREIN HAS BEEN MANUFACTURED, SAMPLED, AND INSPECTED WITH SATISFACTORY RESULTS STRICTLY IN ACCORDANCE WITH THEQUIREMENT43 OF ABOVE SPECIFICATIONS AND PURCHASE ORDE2.THIS REPORT IS ACCORDING TO rRE E NORM EN 1020413.1 hoPs�' r,�� Rovisvv:TED 4I