02-102821 . •
. . -
City ofFedc:a W' r, Building - Single FamilyPermit #:02 - 102821 - 00 - F
Connnunity Development Services g
33530 1st Way S
Federal Way,WA 98003-6210
Ph:253.661.4000 Fax:253.661.4129 Inspection request line: 253.835.3050
Project Name: TRESDEN PLACE LOT#36
Project Address: 29747 30TH AVE S Parcel Number: 868040 0360
Project Description: NSF-Construct NSF w/attached garage,including mechanical&plumbing per BASIC
#01-103424-00. ***Proposed selling price$240,000/4 Bedrooms***
Owner Applicant Contractor Lender
PAGEANTRY COMM OF WASH INI PAGEANTRY COMM OF WASH INI PAGEANTRY COMM OF WASH INl PAGEANTRY COMM OF WASH INl
25400 74TH AVE S 25400 74TH AVE S PAGEACW012DH 1/24/02 25400 74TH AVE S
KENT WA 98032-6011 KENT WA 98032-6011 25400 74TH AVE S KENT WA 98032-6011
KENT WA 98032-6011
Includes:
Census category: 101 -New si #1 #2 , #3 L #4 1
Occupancy Group: 1 R-3 U-1 r
Construction Type: Type V-N Type V-NL.—
Occupancy Load: _
Floor Area(Sq.Ft.):
1st Floor Proposed Sq.Feet 1285 2nd Floor Proposed Sq.Feet 764
Basic Plan Yes Census Category 101 -New single family hous<
Construction Type#2 Type V-N Garage Proposed Sq.Feet 555
Height of Structure 25 Mechanical Ye3
Occupancy Group#1 R-3 Occupancy Group#2 U-1
Plumbing Yes Total Building Sq.Feet 2604
Total'r_opose:d Sq. net 2604 Zoning Designation RS 5.0
Plumbing Fixtures
Description p[Quantityj Description Quantity rDescription Quantity
Dishwashers 1 Gas Pipe Outlets • 2 Laundry Washer Outlets L l
Bathtubs 3 Lavatories 3 Water Heaters J 1
Showers 3 Sinks u 5 Water Closets
1 J 3 J
Mechanical Fixtures
Description _ ' Quantity 1 Description` ,Quantity Description iQuantity,
Fans 4 Ducts 1 1 Fireplace Inserts 1
Ranges I 1 Fumaces 1 Hoods 1
CONDITIONS:
No building shall encroach onto any building setback line or easement shown or not shown.
Maximum building height is 30 feet above average building elevation,per Federal Way City Ordinance#90-51.
Retain&protect identified significant trees per FWCC,Sec.22-1565 through 1569.Bright protective fencing is
required at the dripline of retained trees.
The driveway shall be paved per FWCC,Sec.22-1453.The driveway shall be paved from the existing roadway
pavement edge,or curb,to the garage or carport.
Maximum driveway width is 30 feet.
Building setbacks are: 20 feet front; 5 feet side; 5 feet rear.
Prior to any clearing or grading on a lot,the owner/builder shall install temporary erosion/sedimentation control
facilities approved by the City.These facilities must ensure that dirt or sediment laden water does not enter the l�
public drainage system, adjacent lots or public streets.The owner/builder bears the responsibility to maintain the A. 0�
facilities in nroner working order.replacing as necessary.The facilities may be removed only after such time as C ,I'��
,
J
construction is emplete&landscaping is installed.See attached for standards and site plan for location of silt --
fencing. .
Per FWCC,Sec.22-1133(4),eaves,chimneys or awnings,&similar elements of a structure that customarily
extend beyond the exterior walls of a structure may extend up to 18 inches MAXIMUM into the required yard
setback.Additionally,the total horizontal dimensions of the elements that extend into a required yard,excluding
eaves,may not exceed 25% of the structure's facade length from which the elements extend.
This decision shall not waive compliance with future City of Federal Way codes,policies,or standards relating to
the subject proposal.
All building downspouts,footing drains&drains from all impervious surfaces such as patios&driveways shall
be connected to the approved storm drain outlet as shown on the approved construction drawings.All
connections of the drains must
PERMIT EXPIRES March 3,2003,IF NO WORK IS STARTED.
Permit issued on September 4,2002
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws,rules and regulations of the State of Washington and
the City of Federal Way.
Owner or agent: _ , I I, % Date: 9 0
•
INSPECTION LOG
DATE INSPECTOR OK CORR/REJ AREA AND TYPE OF INSPECTION
%%2 �/�.�o4 4.`e- Ca,�G�I I .4?
POS.IIS CARD ON THE FRONT OF BUILDI. '
CITY Of G
• � BUILDING DIVISION
.\>'•4FD' INSPECTION RECORD
INSPECTION REQUEST PHONE#: 253-835-3050
PERMIT #: 02-102821-00-SF
OWNER'S NAME: PAGEANTRY COMM OF WASH INC
SITE ADDRESS: 29747 30TH S
O FOOTINGS/SETBACKS 9-112-C) S') () FOUNDATION WALL -
' DO NOT POUR CON CE, fri NTIL THE ABOVE IS APPROVED; u
. ..,tea '",.. ,.., _ 4. _ �j � •,.
( ) DRAINAGE: Line //42-0//42-0 % "1/ ( ) Connection 9,V - /tZ-
DO NOT POUR SLAB UNTIL THE ABOVE Y§--APPROVED x.
( ) UNDERFLOOR FRAMING /I/1 /sZ S 5
O ROUGH PLUMBING: DWV //--.22--UL 73 Water piping ///
() ROUGH MECHANICAL ///�(/� 47',' Gas piping /11,7-LA 5`
) SHEATHING 6 Roof /1 -13 -0,2-0 S Floor
( ) SHEAR WALLS ///2 2 //L 95
() ELECTRICAL ROUGH-IN Ditch Cover
( ) FIRE/DRAFTSTOPS
m gym:
AILLTHE=ABOVE':MUST BE APPROVED PRIOYZ TO FRAlYIING INSPECTION` a
O FRAMING/FIRESTOPPING Ar
THE ABOVE MUST BE APPROVED PRIOR T(til sULATING'OR SHEETROCKING"
( ) INSULATION: Floors Walls Attic
THE ABOVE MUST-BE APPROVED PRIOR TO APPLYING SHEETROCK
O WALLBOARD NAILING O SUSPENDED CEILING
THE ABOVE MUST BE APPROVED P,,RIOR I O TAPING OR INST,AL, LTP G"(EILING TILE'. :; .)-4,437
( ELECTRICAL FINAL v?- ) G '7
( ) PLANNING FINAL
() PUBLIC WORKS FINAL
( ) FIRE FINAL
<,1 ,'.. k , M THE ABOVE MUST BE APPROVED PRIOR TO.BUILDING DEPARTMENT FINAL
(,. BUILDING FINAL ^ y - � •- L
�� r - r,,.. a „
DO NOT OCCUPY THIS BUILDING UNTIL BUILDING FINAL'IS APPROVED
•
0
r
Q-,-°f f CONS I RUC,i ION PERMIT APPUcA►IOlN
'jam1---1-1 __ APPLICATION NUMBER: Q 2 - I o 2 e 2.f -00 15 f
APPLICATION NUMBER: - - - j
(�;PPLICA t EON NUt44BER: _ _ _ _ _ _ _ _ _
**The following is required information-?lease print(in ink)or type*
Please note: Electrical,Fire Prevent-on Systems and E .e-erino permi may require a separate appiit tion. 1 1 3667
.- ._.. - _,-- ,,:.- --z "I....-j�1'f Gail -'• i ( 1Fi• _
a - _ - ""�•'. "'ma - .. =- �'.'_-
SITE ADDRESS: 2% 1 - 30-1-1-94.134Zc I ASSESSOR'S TAX/PARCEL#: IV 7 t ti - 0 34.
LEGAL DEsaup;rrON OF SUBJECT PR PERTY(ATTACH SEPA TE DESCRIPTION IF LENGTHY):
36
"46,
. .
. , . ,,,,„...,k, .., ,, : , . , „...._........ _.....,......
TYPE OF PROJECT(This application): gl BUILDING N PLUMBING Lt MECHANICAL ❑ DEMOLITION
❑ ELECTRICAL ❑ ENGINEERIING❑ FIRE PREVENTION SYSTEM
PROJECT DESCRIPTION(Provide detailed description): f -.
-
Single Family Detached Dwelling
Basic Plan # 01-103424
IL 34
PROJECT NAME: Tresden Place C OT
PROPERTY OWNER: i NAME: 7 DAYIIMEP ONE i
14448i:1#410/41001!
Pageantry Communities (253 ) 854 - 0415
MAILING ADDRESS(STREt 1 ADDRESS;CITY,STATE,ZIP):
25400 74th Ave S, Kent, WA 98032 I
CONTRACTOR: NAME:
DAYTIME PHONE:
Pageantry Communities ( 253) 854 - 0415
MAILING ADDRESS(STREET ADDRESS;CITY,STATE,ZIP)` _ - EVENING PHONE
25400 74th Ave S, Kent WA 98032 . , ( ) -
QTY OF FEDERAL WAY BUSINESS LICENSE NUMBER: FAX NUMBER
2 0 - 0 010_28_15_ _ - RT, i ( 25 3) 854 - 9
CONTRACTORS REGISTRATION NUMBER: EXPIRATION DATE:
(copy ofcard required) PAGEACW012DI 01 / 30 /2004
APPLICANT: i NAME: l DAYTIME PHONE
Parrc�n�r i. -
gea��t�y -Communities - ( 253) 854 0415
-- MAILING ADDRESS(STREET ADDRESS;QTY,STATE,ZIP): EVENING PHONE:
25400 74th Ave S , Kent WA 98032 ( ) -
RELAA IONSHIP TO PROJECT: 1 FAX NUMBER
( Eli ARC IIEt i F "E:ANT - v :hER(D�Jc.r.-LBE): Col Frac or I ( 25) 8854 - 9710
E M.. ADDRESS: # _
-CON-TA PERSON FOR-THIS PROJECT: ❑ PROPERTY OWNER L i APPLICANT i.+ Ii CONTRACTOR 1
•
J --.� -_.._�- r F c t k [f (t ft.i i,t i;-K t .-,:'.1 t t _`c 1 -...._-,. .�.. ',v.'�_
Ea S-tiNG USE: VA c/,l/r -.._'---•"-- --.-7N---,EV - !.-":z•-•=('--== .. . -��. a_-. ._
?RD°,'c_ED- -C S FD - 1ATI cti ..- _---___-
3^':._i1t=:= E7 77._- _TV^ YES X7 NO ''::- _ R�^^N -�• -_ P�� -4•----.1'177:1--7--):: .1Y`-2
WATER R SE-ERIK:-2EPROVIDER: SAKEHAVEN i i HT.-----i-i' TACOMA : ._a
SEV-VE_r SET'C E PROV;5Et.= LA.?ZE i \E1t 0HIGH `NE i 1 n: 4=:`. (SEPTIC) - -
" 0 •
.
**NEIAI REcrnErT L1 CONSTRUCTION ONLY** l
NUMBER OF BEDROOMS: 4 ES 11MATED SELLING PRICE: $ 240 ,000
I
e::: . - =o r`-=y,•_.;—s. ra-' s. - ,.-'. 7--7---,7,77-:K al 1�8 I; -moria. "`.v. .,....: ..""_e_'�_„^-.-- =---•..:
FLOOR E)a NG SO- FTit. PROPOSED Ss_FT. TOTAL !
JB EN I • I
F �� l 7 1 t
1 12 85 I
SECOND 764
THIRD ,
FOURTH I f --
OTHER FLOORS(DESCRIBE) I I 1
I !
DECK
:-. ,-i i_r-
GARAGE
5
- - ' HOS MANY FLOORS?
TOTAL 1 2604
Indicate number of each type of fixture
MECHANICAL
AIR.HANDLING UNIT(S) EVAPORATIVE COOLER(S) GAS LOG(S) REFRIG.SYSTEM(S)
4 FAN(S) 1 HOOD(S) WOODSTOVE(S)
BOILER(S) 1 FIREPLACE INSERT(S) 1 RANGE(S) MISC.( )
COMPRESSOR(S) 1 FURNACE(S)< .;
1-•. - -DUCTS)
GAS PIPE OUTLET(S) HEAT SOURCE: ❑ ELECTRIC 2g GAS ,y
PLUMBING - -
i
3 BATHTUB(S) 3 LAVATORY(S) URINAL(S) 1 WATER HEATER(S)
1 DISHWASHER(S) RAIN WATER SYS. VACUUM BREAKER(S) 0 ELECTRIC l GAS -
DRINKING FOUNTAIN(S) 3 SHOWER(S) 1 WASH MACHINE OUTLET MISC.( )
2 GAS PIPE OUTLET(S) 5 SINK(S) 3 WATER CLOSET(S)
INTERCEPTOR(S) SUM P(S)
a1�.�. -> -•,.T '�: 347 . -
I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and
further,� ,L_� I ,, _ _ the ofabovetoperform the work for which the permit application is made. I I
uaut_ am authorized by owner the pr e:^.ise_ r- pp
further hold�_ *- theof Federal Way as to any claim(induding costs,expenses,and attorneys fees incurred in the
agree to a aot unc5a City a '
investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the City of
Federal Way,but only where such claim arises out of the reliance of the city,including its officers and employees,upon the accuracy ;
of the information supplied to the city as a part of this application. 1
I _' DATE: 1 "Z Z
NAME/TITLE: Ail -
i
0_PROPERTY OWNER 0 APPLICANT l CONTRACTOR -
. I =_ a1DDt011= = AL1tRA7ZOtt = = P4Zi2-_-= Iv4CTTIPREi9NT
---=—-=- .}N='-- _— L=to r' -=...` ? —— - .
CJMMUn 'DE1_Ont-4..Nl_-.T = 3i'_irS WAYSaLi_•9-_Ez,DY'°_% WAY,WA SSC%3715-2173-56:1-4000-FAX: ...roc==' -- ! —
I
Construction Permit Fee (_lain t_Iafilnrt. Sheet
*******PLEASE NOTE: ALL FEES MUST BE VERIFIED BY
CITYSTAFF PRIOR TO ACCEPTANCE
NCE OF PAYMENT.
CHECKS FOR INCORRECT AMOUNTS WILL NOT BE ACCEPTED-
''' '*
Building,mechanical,and fire prevention system fees are based On the following schedule.
TABLE A
1 TOTAL VALUATION FEE FACTOR it
11, (1)$1.00 to$5000.00 (1)$26.00 (1
(2)$S0L00 to$2,000_00 (2)$266.00 for the first$500.00 plus S3.50 foreach adcriodai iIOJ GO or frc=en thereof,to and inducing
$2,000.00
(3)$2,00L00 to$25,000.00
(3)$7.8.50 for the first$2,000.00 plus 515.50 for each additionaTSl,LO0.00 or fraction thereof,to and
induding$25,000.00
(4)$25,001.00 to$50,000.00
(4)$435.00 for the first$25,000.00 plus SII-00 for each addxfona/51,000.00 or fraction thereof,to and
induding$50,000.00.
(5)550,001.00 to$100,000.00
(5)$710.00 for the first$50,000.00 plus 58.00 for each additional S1,000C or fraction thereof,to and
' induding$100,000.00.
d (6)$1.00,00.1.00 o$500,000.00
(6)$1,110.00 for the first$100,000.00 plus t6.00 for each additional 5'1.000-09 or fraction thereof,to and
induding$500,000.00
(7)$500,001.00 to$1,000,000.00
(7)$3510.00 for the fist$500,000.00 plus 55.-50 for each ado-Ilona"$1,000.00 or fraction thereof,to and
• induding$1,000,000.00.
(8)$1,000,001.00 and up
(8)$6,260.00 for the first$1,000,000:00 plus S4.00 for each ad<'iona!$!.00^00 or fraction thereof.
Bold number is the base fee for the specified increment
Italicized underiinednumber isthe fee her additional specifiedincrement
PLUS: Add 65 percent of the base building permit fee for plan review fee.
Add 25 percent of the base mechanical pen f,it fee for meduani l plan review fee.
Add 15 percent of the base building permit fee for Ere District#39 surcharge,commercial only.
Add$450 for WA State Building Code Council,plus$2.00 per unit for duplex&above.
**Electrical,plumbing,and mechanical fees are calculated separately** i
•-- _..._.,. -_._ lulu , �. � _
T ROPOSED VALUATION: f
•FEE FACTOR FROM TABLE A:Number: (a)Base Fee:
(b)Additional Increment Fee: - •
Estimated Permit Fee: (1)
Estimated Plan Review Fee: (2)
Estimated FW Fre Department Surcharge: (3)
(COMMERCIAL ONLY) .
.. < r: - !►llt:., ...:.�..t<-S. :�'-.—sem....—.._'�.i i�'}:a'^`i��r,�q— ',_ ..
PROPOSED VALUATION: $2 ,900.00
FEE FACTOR FROM TABLE A: Number: (a)Base Fee:
(b)Additional Increment Fee: If
Estimated Permit Fee:_,(4) I
Estimated Plan Review:Fee: (5,)
PROPOSED VALUATION:
- I E
FACTOR r F iC* TSB_= 7vu r (a)Base Fee: I �.
(b)Acid-tonal Inc ernent l'
Estimated Permit Fee: (6)
�-dmated Pian Review Fee: (;)
- a (10)
Su T-z-3i _('_)—c.?_ 1_`a i{,(Z—,;_(-8)—( ;�2:) = ti-) -
4