Loading...
12-105620 I , t sr 1 411 • ,Mechanical City of Federal Way -1-7- . „ r . Community&Econ.Dev.Services r Permit #: 12-105620-00-M E 33325 8th Ave S k if i Federal Way,WA 98003 4 f - - Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: O'REILLY AUTO PARTS Project Address: 32411 PACIFIC HWY S SUITE A-1 Parcel Number: 150050 0150 Project Description: Replace and relocate(2)rooftop units. • Owner Applicant Contractor LARKSPUR CENTER LLC UNIVERSAL REFRIGERATION INC UNIVERSAL REFRIGERATION INC PO BOX 1762 (GENERAL) (GENERAL) SAN RAMON CA 94583 PO BOX 614 UNIVERI159RF(4/1/14) AUBURN WA 98071-0614 PO BOX 614 AUBURN WA 98071-0614 Additional Permit Information Mechanical Work Valuation 25665 Is this an Online or O.T.C.application? No Mechanical Fixtures Gas Piping 1 Roof Top Units 2 PERMIT EXPIRES Tuesday, July 2, 2013 Permit Issued on Thursday, January 3, 2013 I hereby certify that the above information is co -ct and that the construction on the above described property and the occupancy and th i l • . in a = cir cewith the laws, rules and regulations of the State of Washington the City of Federal Way. Owner or agent- - Date: f/3/7: r Z4 !3 DATE INSPECTOR AREA AND TYPE 0 NSPECTION P-r • THIS CARD IS TO MAIN ON-SITE . ' Construction I ection Record Federal Way INSPECTION REQUE TS: (253)835-3050 PERMIT#: 12-105620-00-ME Address: 32411 PACIFIC HWY S SUITE A-1 Project: LARKSPUR CENTER LLC FEDERAL WAY, WA 98003-8546 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 Mechanical Rough-in(4165) 0 Gas Piping(4125) El Final-Mechanical(4065) Approved Approved to release test Approved By ief Date/-3/- /3 `By Date By <�, , Date e- —L El Rough ElectricalEl Final Electrical El Right of Way Approved Approved Approved By Date By Date By Date Ir ` a - o s � ar�AEGEIVED • � rai way PERMIT SF MF CO EL PL DE EN FP COMMUMIYDEVEIAPMEnNrSERV(CES�� nzat APPLICATION 253-8352607•FAX 2534335-2609 .: P:: DERAL WAY ';,- ., SITE ADDRESS 32411 70.6 <c., a w <S . SUITE/UNIT• ZO'r'G ASSESSOR'S TAX/PARCEL C A ( cow►lv►egciA\ t 5 0 0 5 0 - a l 5 d NAME OF PROJECT \ (Tenant or Homeowner Name) 01*KW Ci'( Al' 7Arzt- ❑BUILDING 0 PLUMBING )(MECHANICAL TYPE OF PERMIT 0 DEMOLITION 0 ELECTRICAL 0 ENGINEERING 0 FIRE PREVENTION 4?%E.040 ' a) 2 t- _ Roo VEMiKti _ ai!Iniii PROJECT DESCRIPTION r -i �� R A N ' . _ be Li - t.c. etniled description of work inclndPd on this permit only {i " v IIIIIIIIMMI NAME PRIMARY PHONE PROPERTY OWNER LAYLX4S V fZ CE.ML-i?... L.LL ( ) - MAILING ADDRESS.CITY,STATE.ZIP E-MAIL . O. 1Z0 11 ' , A,. C.A '4585 OWNER IS ALSO: 0 CONTRACTOR 0 APPLICANT 0 PROJECT CONTACT ,, PRIMARY PHONE NAME �'!C V eN tri ( r �, P�4'�t C r� ( ) - - •t CONTRACTOR RAILING ADDRESS.CITY,STATE,ZIP PC.)'Fc:?< 6,( 4u0,A4r'^ ilt, /1307( Blest ERMII WA STATE CONTRACTOR'S CENSE N EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE M u/c(i(/. /?/ f ? / I / 1/3 /y-r' -107c t7-cc-,: NAME .•,%%--1-4-"-e.....' PRIMARY PHONE APPLICANT ( ) - MAILING ADDRESS.CITY,STATE.ZIP FAX F70 fob 6>(y 44,bt„v-v, /474-. %Q7( ( ) _ PROJECT CONTACT NAME PRIMARY PHONE (The individual to receive and ., .I .:AA.A I t ( z ;) q - respond to all correspondence MAILING ADDRESS,CITY.STATE,ZIP / � �- concerning this application) FC"} 'KG (Ps /v (�t LYAfi1 Cl ALTERNATE CONTACT NAME: PRIMARY PHONE E-MAIL (ZIP )93 - di( Ai .1 At Ai. . - PROJECT FINANCING NAME Q' OWNER-FINANCED Required for projects with A _ YZ .1 i2 LLL value of$5,000 or more MAILING ADD CITY,STATE,ZIP PRIMARY PHONE iRCW 19.27.095) 'P.O. A 1 AN Ong LA d Sq ( ) - I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. Ifurther agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person, including the undersigned,and filed against the city,but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the ci • . .• oft application. ----------or / �y SIGNATURE: `,, Alla" v ! DATE iii a //-- PRINTN is• /4Ai'N 11Aw419IEAJ Bulletin#100 Page 1 of.3 k:\Handouts\Permit Application 91 • • MECHANICAL FIXTURES R Value of Mechanical Work$ 4 Us. (A COPY OF BID OR ESTIMATE MUST BE PROVIDED) Indicate number of each type of fudure to be installed or relocated as part of this project. Do not include existing fixtures to remain. 2. AIR HANDLING UNITS FANS Z GAS PIPE OUTLETS OTHER(Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS(commerofa( BOILERS FURNACES ' HOT WATER TANKS(cas) COMPRES/�ORS \ GAS LOG SETS REFRIGERATION SYST 2. DUCTING 1x11 4)a I J GAS PIPING WOODSTOVES `` PLUMBI RES . Indicate number of each type offixture to or relocated as part of this project. Do not include existing fixtures to remain._ BATHTUBS(or Thb/Shower Combo) LAVS(Hand Sinks) TOILETS WATER PIPING - DISHWASHERS RAINWATER SYSTKMS U'r 1114. OTHER(Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKIN '•UNTAINS SINKS Kitchen/Utility) WATER HEATERS(Electric) H a: BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION • PROJECT VALUATION WATER PURVEYOR SEWER PURVEYOR. ' VALUE OF EXISTING IMPROVEMENTS ffi OUS USE/ LOT SIZE Oa Square Feet) EXISTING FIRESYSTEM? PROPOSED SUPPRESSION SYSTEM? n Yes No 0 Yes) NO RESIDENTIAL AREA DESCRIPTION(in square feet) EXISTING • PROPOSED TOTAL FOR OFFICE USE BASEMENT _.__�w�_..___-__.._ FIRST FLOOR(or Mob Home) _•___��_.—__ _.______ .. _._____�.___ SECOND FLOOR ______.___._ COVERED ENTRY ____._.. __._._._._.-___ .____ ._______. DECK GARAGE 0 CARPORT 0 — OTHER(describe) —_ ____ _______.._. Area Totals �'G PROPOSED Tare" —_._ __- ---____. '•NEW HOMES ONLY" ESTIMA D SELLING PRICE$ #OF BEDROOMS COMMERCIAL-NEW/ADDITION AREA DESCRIPTION . Area Construction #of in Square Feet Occupancy Group(s) Type Stories Additional Information NEW BUILDING '-----.-.----- ADDITION 1` / COMMERt L REND /TENANT IMPROVEMENTS AREA DESCRIPTION Area Construction #of is Square Feyt ''•f Occupancy Group(s) �, Stories Additional Information TOTAL BUILDING TENANT AREA O PR AREA ONLY Bulletin#100 Page 2 of 3 k:\Handouts\Permit Application • i POE Engineering, Inc. . ,x;" CIVIL&STRUCTURAL ENGINEERING/CONSULTING i, ; 1314 8TH STREET N.E.,SUITE 201 lit Mai"�'II AUBURN,WASHINGTON 98002 (253)833-4052• FAX(253)833-4053 January 18,2013 Universal Refrigeration 4102 "B" Place N.W. P.O. Box 614 Auburn,WA 98071-0614 Attn: Mr. Heath Hamblin Re: Larkspur Center Suite A-1 HVAC Review 32411 Pacific Highway South,Federal Way, WA Dear Heath, Attached is a detail for sleeper framing to replace the prior detailed sub-framing for the mechanical units to be added to the roof for the Suite A-1 at 32411 Pacific Highway South,Federal Way, WA. Maintain the same unit placement as noted in the prior analysis. Provide the sleeper frame as noted on the attached sketch to spread the unit loading over(7)roof joists and support the curbing at the ends of the unit back to the 4x6 main sleepers. Framing shall be pressure treated and flashed/roofed over per the roofing subcontractor. The sleeper frame shall be attached to the roof structure below using 3/16"wood screws with 2"penetration at 16"o/c(pilot holes required for installation). The unit shall be fastened to the curbing fastened to the sleeper frame per the manufacturers ronunendations for 85 mph Exp B wind loading and Seismic Site Class D(Sds 0.830) per the 2009 International Building Code. As a minimum,the unit curbing shall be attached with#10 screws @ 12" o/c on all sides of the unit. Please call with any comments or questions. Sincerely, POE Engineering,Inc. r Alan F.Poe,P.E. { Attachments * f ;- > I 1 1 POE Engineering, Inc. JOB `, Civil & Structural Engineering/ConsultingSHEETro. i Of I 1314 8th Street NE, Suite 201 t Auburn, WA 98002 CALCULATED BY r1=' DATE (253) 833-4052 FAX (253) 833-4053 CHECKED BY DATE SCALE V---'eU+.- 41/4.-.' s PC..R. Fr�.e,s-k.t `r-D r o ff- ♦tS, 5ie .r4-tt ( N-4-4,is t.F`¼ 4.-r t.. +laaw + . c-. .. c' 17C rt x.,1"1, ..-,, 6 ((......r LACPAINSZi c LA / 'LV142 4 al a -t.o cry r ? C , r =........_.-=-1,...— --.......0 -rr---.& .0. i .. (-=_._ 6 111 7-lc ti.-L. —=- __— g- Ike. 4 — —� Q tA 11 Ci 4 0,..., 9 0 1 i 0 � i wr ver= A V ems. die x Co v.gvi,7_, s. c.E. 9-- r D PRODUCT 207