Loading...
16-102638 Building - Single Family City of Federal Way Permit #: 16-10263$-00-S F Community&Econ.Dev.Services 33325 8th Ave S Federal Way,WA 98003 Request Inspection Re Line: Ph:(253)835-2607 Fax (253)835-2609 p q (253)835-3050 Project Name: PINE WOODS AFH Project Address: 2526 SW 323RD ST Parcel Number: 873180 0420 Project Description: ALT-Verification of Occupancy for Adult Family Home. ***No construction work allowed under this permit.*** wn r Applicant Contractor Lender PATRICK AYUMA PATRICK AYUMA 2526 SW 323RD ST 2526 SW 323RD ST FEDERAL WAY WA 98023 FEDERAL WAY WA 98023 Census Category: 434-Residential alt/add-no change in number of units Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load Floor Area(sq.ft.) 0 0 0 0 Additional Permit information New/Additional Sq.Feet-3rd Floor 0 New/Additional Sq.Feet-Basement 0 Calculated Structure Valuation 0.00 Occupancy#1 -Construction Type. Type V-B Mechanical to be Included? No Occupancy#1 -Class R-3 Plumbing to be Included? No Occupancy#1-Use Residence(1 or 2 family) No Fixtures Associated With This Permit!! PERMIT EXPIRES Sunday, November 27, 2016 Permit Issued on Tuesday, May 31, 2016 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: PC?jtj ✓L I Date: -75-1 i 1201 Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST • Code References:2012 IRC Section R325(WAC 51-51) 3 APPLICATION NUMBER: / /O --// 00? 6 F SECTIONS 1.2.3. AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION WILL BE PROCESSED SECTION 1—PROPERTY INFORMATION SITE ADDRESS: d 5,q G S i,ik) at) ST, Ft-oeiztvi-- WA/ �h'o2 3 ASSESSORS TAX(PARCEL#:S! 3 go-70 p SECTION 2 —APPLICANT INFORMATION PROPERTY OWNER NAME: p$772.1 CIC- /'I LAroA DAYTIME PHONE: ( /2 2 FSL) /;3+ AFH LICENSEE NAME(IF DIFFERENT): piroc woods /-Ft1 i-LC DAYTIME PHONE: ash67"8g-g) SECTION 3— FLOOR PLAN On a separate sheet of paper (8 1/2 x 11) draw a floor plan (including all floors) of your prospective AFH. Include all sleeping rooms (bedrooms) indicating which bedroom is: A, B, C D, E and F. Label all components for exiting i.e., stairs, ramps, platforms, lifts and elevators. SECTION 4— DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and that I am requesting or I am authorized by the owner of the above premises to request inspection for the operation of an Adult Family Home at this location. I agree to hold harmless the jurisdiction conducting such inspections, at my request, as to any claim (including costs, expenses, and attorneys'fees incurred in the investigation of such claim), which may be made by any person, induding the undersigned, and filed against the jurisdiction, but only where such claim arises out of the reliance of the jurisdiction, including its officers and employees, upon the accuracy of the information supplied to the jurisdiction as a part of this application. NAME/TITLE: para-_, GIL kr-144 l CFO DATE: S f 30/20 /(o 0 PROPERTY OWNER APPLICANT 0 LICENSEE Effective: 2013 July 01 Updated: 2013 June (Effective July 1, 2013.) WAC 51-51-0325 Section R325—Adult family homes. SECTION R325 ADULT FAMILY HOMES R325.1 General.This section shall apply to all newly constructed adult family homes and all existing single family homes being converted to adult family homes.This section shall not apply to those adult family homes licensed by the state of Washington department of social and health services prior to July 1,2001. R325.2 Submittal standards. In addition to those requirements in Section 106.1,the submittal shall identify the project as a Group R-3 Adult Family Home Occupancy.A floor plan shall be submitted identifying the means of egress and the components in the means of egress such as stairs, ramps, platform lifts and elevators. The plans shall indicate the rooms used for clients and the sleeping room classification of each room. R325.3 Sleeping room classification. Each sleeping room in an adult family home shall be classified as: 1.Type S-Where the means of egress contains stairs, elevators or platform lifts. 2. Type NS1 -Where one means of egress is at grade level or a ramp constructed in accordance with R325.9 is provided. 3. Type NS2-Where two means of egress are at grade level or ramps constructed in accordance with R325.9 are provided. • / R325.4 Types of locking devices and door activation.All bedroom and bathroom doors shall be openable from the outside when . locked. 4 Every closet shall be readily openable from the inside. Operable parts of door handles, pulls, latches, locks and other devices installed in adult family homes shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. Pocket doors shall have graspable hardware available when in the closed or open position. The force required to activate operable parts shall be 5.0 pounds(22.2 N)maximum. Required exit doors shall have no additional locking devices. Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing reentry into the adult family home without the use of a key,tool or special knowledge. R325.5 Smoke and carbon monoxide alarm requirements.All adult family homes shall be equipped with smoke and carbon monoxide alarms installed as required in Sections R314 and R315.1.Alarms shall be installed in such a manner so that the detection device warning is audible from all areas of the dwelling upon activation of a single alarm. R325.6 Escape windows and doors. Every sleeping room shall be provided with emergency escape and rescue windows as required by Section R310. No alternatives to the sill height such as steps, raised platforms or other devices placed by the openings will be approved as meeting this requirement. R325.7 Fire apparatus access roads and water supply for fire protection.Adult family homes shall be served by fire apparatus access roads and water supplies meeting the requirements of the local jurisdiction. R325.8 Grab bar general requirements.Where facilities are designated for use by adult family home clients,grab bars for water closets, bathtubs and shower stalls shall be installed according to this section. R325.8.1 Grab bar cross section.Grab bars with a circular cross section shall have an outside diameter of 1 1/4 inches minimum and 2 inches maximum. Grab bars with noncircular cross section shall have a cross section dimension of 2 inches maximum and a perimeter dimension of 4 inches minimum and 4 5/8 inches maximum. R325.8.2 Grab bar installation.Grab bars shall have a spacing of 1 1/2 inches between the wall and the bar. Projecting objects, control valves and bathtub or shower stall enclosure features above, below and at the ends of the grab bar shall have a clear space of 1 1/2 inches to the grab bar. EXCEPTION: Swing-up grab bars shall not be required to meet the 1 1/2 inch spacing requirement. Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar,fastener, mounting device or supporting structural member. Grab bars shall not be supported directly by any residential grade fiberglass bathing or showering unit.Acrylic bars found in bathing units shall be removed. Fixed position grab bars,when mounted, shall not rotate, spin or move and have a graspable surface finish. Effective: 2013 July 01 Updated: 2013 June NAME OF AFH: Pa rt€ D o dS ,4 r HSECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. PLEASE CHECK ALL APPLICABLE BOXES;MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN-USING THEIR PROSPECTIVE RESIDENT BEDROOM DESIGNATIONS OF A B CD E AND FANO CLASSIFICATION CODE S.NS1 OR NS2. SECTION 5—BUILDING INSPECTOR'S INSPECTION CHECKLIST R325.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area. Type NS1—where 1 means of egress at grade level(has no stairs)or ramp constructed compliant with R325.9 is provided to evacuate residents to public area. Type NS2—where 2 means of egress at grade level(both have no stairs)or ramps constructed compliant with R325.9 are provided to evacuate residents to public area. SLEEPING ROOM A �es 0 Type S D1ype NS1 0 Type NS2 YES NO Closet door/s are readily openable from the inside D" 0 No Smoke alarm is installed in the bedroom 0/0 Bedroom door opens easily and quickly from the outside when locked VI Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) EXCEPT per R310.1.1:at-grade escape windows-may have net clearance opening 5 SF i Sleeping room window has a maximum sill height of 44"above floor;no steps under ow permitted 0' 0 SLEEPING ROOM B 0 Type S ype NS1 0 Type NS2 YES Oes Closet door/s are readily openable from the inside 0 No Smoke alarm is installed in the bedroom d Bedroom door opens easily and quickly from the outside when locked 0 Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) C EXCEPT per R310.1.1:at-grade escape windows-may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"above floor; no steps under ow permitted 0/ 0 SLEEPING ROOM C 0 Type S ype NS1 0 Type NS2 YES NO Closet door/s are readily openable from the inside es 0 No Smoke alarm is installed in the bedroom 0" 0 Bedroom door opens easily and quickly from the outside when locked al' 0 Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0/ 0 EXCEPT per R310.1.1:at-grade escape windows-may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"above floor; no steps under wi ow permitted IVO SLEEPING ROOM D 0 Type S ype NS1 0 Type NS2 YES NO Closet door/s are readily openable from the inside es 0 No Smoke alarm is installed in the bedroom 0�//0 Bedroom door opens easily and quickly from the outside when locked W' 0 Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) D' 0 EXCEPT per R310.1.1:at-grade escape windows-may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"above floor; no steps under w ow permitted 0` 0 SLEEPING ROOM E 0 Type S D'fype NS1 0 Type NS2 YES NO Closet door/s are readily openable from the inside es 0 No Smoke alarm is installed in the bedroom CV- Bedroom VBedroom door opens easily and quickly from the outside when locked 0 Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0/0 EXCEPT per R310.1.1:at-grade escape windows-may have net clearance opening 5 SF / Sleeping room window has a maximum sill height of 44"above floor;no steps under window permitted r14.----1 SLEEPING ROOM F 0 Type S 0 Type NS1 0 Type NS2 YES NO Closet door/s are readily openable from the inside 0 Yes 0 No Smoke alarm is installed in the bedroom 0 0 Bedroom door opens easily and quickly from the outside when locked 0 0 Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0 0 EXCEPT per R310.1.1:at-grade escape windows-may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"above floor;no steps under window permitted 0 0 Effective: 2013 July 01 Updated: 2013 June R325.8.3 Grab bars at water closets.Water closets shall have grab bars mounted on both sides. Grab bars can be a combination of fixed position and swing-up bars. Grab bars shall meet the requirements of R325.8. Grab bars shall mount between 33 inches and 36 inches above floor grade. Centerline distance between grab bars, regardless of type used, shall be between 25 inches minimum and 30 inches maximum. R325.8.3.1 Fixed position grab bars. Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from the rear wall. R325.8.3.2 Swing-up grab bars.Swing-up grab bars shall be a minimum of 28 inches in length from the rear wall. R325.8.4 Grab bars at bathtubs.Horizontal and vertical grab bars shall meet the requirements of R325.8. R325.8.4.1 Vertical grab bars.Vertical grab bars shall be a minimum of 18 inches long and installed at the control end wall and head end wall. Grab bars shall mount within 4 inches of the exterior of the bath tub edge or within 4 inches within the bath tub. The bottom end of the bar shall start between 36 inches and 42 inches above floor grade. EXCEPTION:The required vertical grab bar can be substituted with a floor to ceiling grab bar meeting the requirements of R325.8 at the control end and head end entry points. R325.8.4.2 Horizontal grab bars. Horizontal grab bars shall be provided at the control end, head end, and the back wall within the bathtub area. Grab bars shall be mounted between 33 inches and 36 inches above floor grade. Control end and head end grab bars ' shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length. R325.8.5 Grab bars at shower stalls.Where shower stalls are provided to meet the requirements for bathing facilities, grab bars shall meet the requirements of R325.8. EXCEPTION: Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab bars at the seat end wall. A vertical floor to ceiling grab bar shall be installed within 4 inches of the exterior of the shower aligned with the nose of the built-in seat. R325.8.5.1 Vertical grab bars.Vertical grab bars shall be 18 inches minimum in length and installed at the control end wall and head end wall. Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower stall.The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. R325.8.5.2 Horizontal grab bars. Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 inches and 36 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent walls. Horizontal grab bars shall not interfere with shower control valves. R325.9 Ramps.All interior and exterior ramps,when provided, shall be constructed in accordance with Section R311,8 with a maximum slope of 1 vertical to 12 horizontal. The exception to R311.8.1 is not allowed for adult family homes. Handrails shall be installed in accordance with R325.9.1. R325.9.1 Handrails for ramps. Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal and 1 vertical and 20 horizontal in accordance with R311.6.3.1 through R311.6.3.3. R325.10 Stair treads and risers.Stair treads and risers shall be constructed in accordance with R311.7.4, Handrails shall be installed in accordance with R325.10.1. R325.10.1 Handrails for treads and risers. Handrails shall be installed on both sides of treads and risers numbering from one riser to multiple risers. Handrails shall be installed in accordance with R311.7.7 through R311.7.7.4. R325.11 Shower stalls.Where provided to meet the requirements for bathing facilities,the minimum size of shower stalls for an adult family home shall be 30 inches deep by 48 inches long. [Statutory Authority:RCW 19.27.031 and chapters 19.27 and 34.05 RCW.13-04-068,§51-51-0325,filed 2/1/13,effective 7/1/13.Statutory Authority:Chapter 19.27 RCW. 10-18-036,§51-51-0325,filed 8/25/10,effective 9/25/10.Statutory Authority: RCW 19.27.190,19.27.020,and chapters 19.27 and 34.05 RCW.09-04-023,§51-51-0325,filed 1/27/09,effective 7/1/10.Statutory Authority:RCW 19.27.074, 19.27.020,and chapters 19.27 and 34.05 RCW.07-01-090,§51-51-0325,filed 12/19/06,effective 7/1/07.Statutory Authority:RCW 19.27.031 and 19.27.074.04- 01-109,§51-51-0325,filed 12/17/03,effective 7/1/04.] Effective: 2013 July 01 Updated: 2013 June R325,8 Grab Bars in Bathrooms N/A Q YES` NO Greb bars shall be installed for all water closets(toilets),bathtubs and showers according to R325.8. E.' 0 Water Closets(toilet)shall have grab bars installed on both sides according to R325.8—R325.8.3.2. Bathtubs shall have two vertical and three horizontal grab bars installed according to R325.8—R325.8.2&R325.8.4—R325.8.4.2 Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower according to R325.8—R325.8.2& ItY 0 R325.8.5—R325.8.5.2. Shower stalls must be minimum size of 30 inches deep by 48 inches long(R325.11) AG103—AG105 Swimming Pool,Spa,Hot Tub YES NO AF105.2 Must be surrounded by a barrier that is 4$n ,may have doors and or gates that must have audible alarms when o o opened. AG105.5 EXCEPTION:Pools, as or Hot Tubs with a safety cover which complies with ASTM F 1346 0 0 ASSED DCORRECTIONS REQUIRED 0 PERMIT REQUIRED s� - � INSPECTOR'S N E(PRINT) ff C C INSPECTOR'S SIGNATURE DATE: INSPECR'S OFFICE ADDRESS ( PHONE NUMBER: Application and inspection checklist developed by Washington Association of Building Officials(WABO),in cooperation with Department of Social and Health Services(DSHS)for use by both departments and licensors. 07/01/2013 Effective: 2013 July 01 Updated: 2013 June GENERAL YE$ NO Bathroom doors are easily and quickly openable from the outside when locked Carbon Monoxide alarms are installed as required in R315.1 on each level of the home. 00 Smoke alarms are installed on all levels of the dwelling,in each resident sleeping room,outside each separate sleeping area in the immediate vicinity of sleeping rooms(R314). Lam'IJ Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all C1-1.1 parts of the dwelling upon activation of a single device. Access road and water supply meet local fire jurisdictional requirements. 121-'0 R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). Pocket doors shall have graspable hardware available when in the closed or open position. Er. 0 R311.8 Ramps � YES NO Inside Ramp N/A 0 0 R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) 0 0 R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes directions. 0 0 R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. 0 0 Outside Ramp N/A 0 YES R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes directions. R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. Guards below are depicted vertically as an example only.All Ramps must have Guards Handrail both sides Less than 4" /34"-38" Guard I rjSj' *Uiui.....i..... 111 36"min 1 ��._.� 11 3'x 3'min landing landing - 3' One unit vertical in twelve units horizontal 1- 3' minimum is an 8.3%slope all along surface of the ramp. minimum R311.2 Means of Egress YES iNO R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. 1 R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). R325.4 Required exit door hard are shall unlock inside and outside mechanisms when exiting the building allowing re-entry 0 without use of key,tool ors tial knowledge. Required exit door shall have no additional locking devices. R311.7 Stairways N/A or YES NO R311.7.4.1 Riser Height:Max riser height shall be 7% inches(8 inches in structures built prior to July 1,2004) 0 0 R311.7.4.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built prior to July 1,2004) 0 0 R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple 0 0 risers.Handrails shall be installed in accordance with R311.7.7.1—R311.7.7.4 Effective: 2013 July 01 Updated: 2013 June r `+ • ." . • alt A I 'a) v i \-1, 2 0 1- d 1 .., 1 3 o S i 4.-- ?, T. w 4 F z 7_ i • PERMI,APPLICATION r CITY OF REC EIVED Federal Way /,., 0 ��j MAY 31 2016 PERMIT NUMBER /Y/ / 3 F - TARGET DATE CITY OF FEDERAL WAY CDS SITE ADDRESS SUITE/UNIT# ,(5,-“0 3 3.23 e-D ST , Pe'D QPi-L- vJ NI WIN clgpla PROJECT VALUATION ZONING ASSESSO$:$Th$�pARC ' E3 0 - 0 4 c TYPE OF PERMIT CS(BUILDING 0 PLUMBING 0 MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION NAME OF PROJECT /Aft iNaoz c A-P+t PROJECT DESCRIPTION D,S/ts /;^✓ PCC-7-/vn) %D Vc-y -i -� ffprY1L !S fin/ C�rnP2/itrllC.e Detailed description of work to A Di-(.U F/)-''/J 1 1-'1 tic-114 f k ice'th OtA 4 )+8-v'»i Ly /fib me be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER P,,J2/Ck- A-YarmA- MAILING ADDRESS AI E-MAIL a52�„ 323lZD si CITY STATE ZIP F rzq L 14A/ Par- 98023 NAME PHONE . MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# NAME PRIMARY PHONE P#37121 6--4- Y r-�A APPLICANT MAILING ADDRESS E-MAIL 26 s fro 32 3 G2 s7- CITY STATE ZIP FAX z�--i wA-y 1/1(h- C 2-3 NAME PRIMARY PHONE PROJECT CONTACT (The individual to receive and MAILING ADDRESS E-MAIL respond to all correspondence concerning this application) CITY STATE ZIP FAX NAME PROJECT FINANCING 0 OWNER-FINANCED When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. i SIGNATURE: G� q DATE s 13f /24,14, PRINT NAME: P R-I C R Niu VY)is Bulletin#100—February 22,2016 Page 1 of 2 k:\Handouts\Permit Application