Loading...
16-105823City of Federal Way ^ Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835.2607 Fax: (253) 835-2609 Project Name: GAUTHIER Project Address: 2231 SW 309TH ST Building - Sir -J. -Family Permit #:16-105 �3-A-Si Inspection Request Line: (253) 835-3050 Parcel Number: 416790 0160 Project Description: ADD - Construct a 352 square foot addition, 27 square foot entry way and interior remodel that consist of replacing kitchen windows, replacing slider to deck with single door, remove interior walls and adding new roof. Plumbing and Mechanical included. Owner Applicant Contractor Lender DANIEL T GAUTHIER DANIEL T GAUTHIER RENEWAL CONSTRUCTION LLC OWNER IS LENDER 2231 SW 309TH ST 2231 SW 309TH ST 14110 CANYON RD E No FEDERAL WAY WA 98023-7823 FEDERAL WAY WA 98023-7823 PUYALLUP WA 98373 SF - High -Density Census Category: 434 - Residential alt/add - no change in number of units Includes: #1 #2 #3 #4 Occupant Class: R-3 Construction Type: Type V - B Occupancy Load: 0 Floor Area (sq. ft.) 352.00 0.00 Additional Permit Information New / Additional Sq. Feet - 1st Floor ..................... 352 New / Additional Sq. Feet - 3rd Floor ..................... 0 New / Additional Sq. Feet - Basement .................... 0 New / Additional Sq. Feet - Deck ........................... 0 Mechanical to be Included? ..................................... Yes Mechanical Work Valuation? .................................. 2000 New / Additional Sq. Feet - Other ........................... 27 Plumbing to be Included? ........................................ Yes Occupancy #I - Use ................................................ Residence (1 or 2 family) Zoning DesiRnation................................................. RS 9.6 New / Additional Sq. Feet - 2nd Floor .................... 0 Occupancy #I - Area (Sq. Feet) .............................. 352 Occupancy # 1 -Construction Type ......................... Type V - B New / Additional Sq. Feet - Garage ........................ 0 Plumbing Work Valuation? ..................................... 2100 Number of Stories ................................................... 2 Is this an Online or O.T.C. application? .................. No New / Additional Sq. Feet - Total ........................... 379 Comprehensive Plan Designation ........................... SF - High -Density Residential Ducting 1 Fans 1 Gas Piping 1 Dishwashers 1 Sinks 1 Hose Bibbs PERMIT EXPIRES Saturday, 8 July, 2017 Permit Issued on Monday, January 9, 2017 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the y ewill be in accordance with the laws, rules and regulations of the State of Washi on and the City of Federal Way. Owner or agent: Date: 1A // 7 O. AREA AND TYPE OF INSPECTION � 1 � � � ���ki a 1 �o 'H - �� �i a► �oki k 5 �k� N«d � i Yvv- urivcw& p4*;14 Wall �Ib}iH S.• lot rvM �.t CITY OF Federal way THIS CARD IS TO REMAIN ON-SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 0 Mechanical Rough -in (4165) PERMIT #: 16 105823 00 Fire/Draft Stops (4095) Address: 2231 SW 309TH ST Approved Project: KAREN D GAUTHIER FEDERAL WAY WA 98023-7823 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. By Date SWM Precon Site Mtg (4400) ® Initial Erosion Control (4365) 3❑ Footings/Setback (4110) Approved Approved Date To be done PRIOR to breaking ground Approved to place concrete By Date By Date By Date Date Foundation Wall (4115) Li Drainage/Downspout (4040) ® Plumbing Groundwork (4190) Approved to place concrete Approved to backfill Approved to cover By Date J 27 By Date By Date Slab/Concrete Floor (4255) 0 Underfloor Framing (4285) Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By Date , 1 le By Date El Shear Walls (4245) Roof Sheathing (4220) Rough Plumbing (4230) Approved to install siding Approved to install roofing Approved By Date ��/ By Date L By C Date _:22 0 Mechanical Rough -in (4165) Gas Piping (4125) Fire/Draft Stops (4095) Approved to install wallboard Approved Approved to release test Approved Right of Way By Date By Date By ��� Date 1"-_ 4 By Date 1 Interim Erosion Control (4370) Prior to scheduling a Framing inspection; E7 Framing (4120) Approved Electrical, Plumbing & Mechanical Rough -in Approved to insulate and Fire/Draft Stop P g inspections must be signed off anapproved. IBC 109.3.4 By Date d PP By Date Insulation (4150) 1 Gypsum Wallboard Nailing (4130) Final Erosion Control (4375) Approved to install wallboard Approved to install mud & tape Right of Way ---Approved By Date v .>>� By Date 5�5 �/` By Date � , Final - Mechanical (4065) Final -Plumbing (4075) Final - Building (4050) Approved Approved Approved By Date T �'l (� (" By I(W4 Date -71-4t 117 By .. - Date �. ❑ Rough Electrical Final Electrical Right of Way Approved I Approved Approved By Date By Date By Date PERM IT'OAPPLICATION CI , r PERMIT CENTER + 3 _ ue South +Federal Way, WA 98003-6325 Federal Way253 835-2607 + F 5 609 + permitcenter ci.cityoffederahvay.Com pec 0'.8 Zoos PERMIT NUMBER � � _ / � 5 g Z 1p.TT� OF FEDWAlL9VAy SITE ADDRESS SUITEJUNIT # PROJECT VALLUATION $ i ZONING ASSESSOR'S TAX/PARCEL# /(, ri O OVU " ( / TYPE OF PERMIT BUILDING CTPLUMBING MECMAN[CAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT ,� t� T f e CE t t PROJECT DESCRIPTION x 'ro'"" � Detailed description of work to t f r 2yn& be included on this permit only s1 fe. oR ae_ -T-Vto R c is Akw Roof NAME ((� ' PRIMARY PHONE 15 3 PROPERTY OWNER MAILING ADDRESS 30(i.t E-MAIL 5 = � i" u til Cas— n7 CITY tt`ry STATE NAME i PHONE .., 13l MAILI}NG ADDRESS E-MAIL CONTRACTOR CITN' STAT,IE� ZIP 7'`( "j �y FAX 7 WA Si'TA� $$CONTgg CTOR'S LICENSE # L- EXPIRATION DAjjTE7' FEDERAL WAY BUSINESS LICENSE # .� to . i 1st id up 1�-- NAME —a PR^I'MARY PHONE MAILING ADDRESS i _J C C,6Lt 2231 E-MAIL Y .t} GttSi?t APPLICANT CITY` ry STATE # ZIP W AX PROJECT CONTACTL;' NAME i L )" a,; PRIMARY PHONE MAILING ADDRESS E-MAIL (The individual to receive and respond to all correspondence CITY STATE ZIP FAX concerning this application) NAME OWNER PROJECT FINANCING 0 v , -FINANCED MAILING ADDRESS, CITY, STATE, ZIP..``�� ,,� PHONE �c�y ' i0 -L1 ,. V !J L4 When value is $5,000 or more (RCW 19-27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal Iaws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied the city as apart of this application. f SIGNATURE: DATE (( J { PRINT NAME: %� L.--+ I I ( _Yi E� Bulletin #100 —January 29, 2016 Page i of 2 k:\Handouts\Pennit Application PI MECHANICAL, PERMIT Indicate how many of each typ 0 AIR HANDLING UNITS AIR CONDITIONER 0 BOILERS 0 COMPRESSORS I DUCTING VALUE OF PLUMBING WORK PLUMBING PERtiIIT $ > Indicate how many o each type of Lrture to be installed or relocated as part of this project. Do not include existing factures to remain. BATHTUBS (or Tub/Sho , combo) VALUE" OF MEChfANICAL WORK��., VALUE OFJJJEXISTING IMPROVEMENTS TOILETS > WATER PIPING t oc .c0 to be installed or relocated as parl of this project. Do not include existin futures to remain. FANS _I GAS PIPE OUTLETS OTHER (Describe) FIREPLACE INSERTS A HOODS (c...—id) SHOWERS FURNACES 0 HOT WATER TANKS tars) COVERED ENTRY GAS LOG SETS 0_ REFRIGERATION SYST p� GAS PIPING is WOODSTOVES HOSE BIBBS VALUE OF PLUMBING WORK PLUMBING PERtiIIT $ > Indicate how many o each type of Lrture to be installed or relocated as part of this project. Do not include existing factures to remain. GE Ni RAL€ILII a_�s«vpA-1t-rjti BATHTUBS (or Tub/Sho , combo) LAVS (Hmnd Sinks) VALUE OFJJJEXISTING IMPROVEMENTS TOILETS > WATER PIPING -- TIfSH{N?.SHF.Rg ((;i_ RAIN6U ATF.R CY STF.MC EXISTING FIRE SPRINKLER SYSTEM? �No t1R.1NAl_S 0 OTHER (De,s"ita) DRAINS = Yes SHOWERS _ VACUUM BREAKERS _.._.. _.._.. _............... .__._............... .-_... _._._.... _.... _......... .._.................... .... COVERED ENTRY DRINKING FOUNTAINS �_ SINKS {Kitchen/Utility) p� WATER HEATERS (Electric) --- HOSE BIBBS _ SUMPSi. J WASHING MACHINES TOTAL FIXTURES GE Ni RAL€ILII a_�s«vpA-1t-rjti CRITICAL AREAS ON PROPERTY? WATER PURVEYOR,, SEWER PURVEYOR �t {. VALUE OFJJJEXISTING IMPROVEMENTS FOR OFFICE USE BASEMENT -- _ — I EXISTING/PREVIOUS USE LOT SIZE IIn Square Feet) EXISTING FIRE SPRINKLER SYSTEM? �No PROPOSED FIRE SUPPRE3GI N SYSTEM?I i � VNo Fr L S c: Yes = Yes i Er;+:/ OR AD AREA DESCRIPTION (in square feet) EXISTING PROPOSED ( TOTAL FOR OFFICE USE BASEMENT -- _ — iFIRST FLOOR (or Mobile Home) (,qzli SECOND FLOUR AREA DESCRIPTION Area in Square Feet Occ ancy Group(s) _.._.. _.._.. _............... .__._............... .-_... _._._.... _.... _......... .._.................... .... COVERED ENTRY ditional Information 1 _....__........-....__.._-......_._._...... DECK --- ---. _.._..._..._..._.._...._..._........_...................... _._........... I GARAGE M/CARPORT O --- ------. .._....._........... - ..... ........... -- OTHER (describe) __....__...... _ . _.... t� X,A G [.4. 1 (% LLC LJ r EXIST.I�NyG �-} ,....P '�"P`PROPOSED ✓ 2 ice... O -.--.-___-_..._ . **ATW HOMES ONLY**** ESTIMATED SELLING PRICE $ J # OF BEDROOMS �1MEI2CIAE — NEW/ADDITION AREA CRIPTION Area in Square Feet Occupancy Group(s) Construction t ype # of Stories Additional Information NEW BUILDI ADDITION COMMERCIAL — REMODEUTEN :LMKIMPROVEIVIENTS AREA DESCRIPTION Area in Square Feet Occ ancy Group(s) Construction Type # of Stories ditional Information —MAL BUILDING TENANT AREA ONLY PROJECT AREA ONLY Bulletin # 100 - January 29, 20 i 6 Page 2 of 2 k:\Handouts\Permit Application L, ADDENDUM 2 FOUNDATION REVISIONS PER OWNER COMMENT of GAUTHIER RESIDENCE 2231 SW 309TH ST. FEDERAL WAY, WA 98023 for ERIC ISAACSON RENEWAL REMODELS & ADDITIONS 14110 CANYON ROAD EAST PUYALLUP, WA 98375 by THE LAND DEVELOPER'S ENGINEERED SOLUTION A Division of THE LAND DEVELOPER, LLC Erik B. Ainsworth, PE PO Box 4420 Tumwater, WA 98501 (360) 250-3973 February 21, 2017 Project Number: 16-100 GAUTHIER RESIDENCE I--__------------- --- ------------------------- I I I I; I I I I I I I I I i I I I I I I I I I I ; I I I I I I I I I � I I I I I I ; I I I A I I I I I I I EPDXY HOR. REBAR INTO EX. 2X10 PT LEDGER ANCHORED I FOUNDATION REF.TO EX. HANG NEW FLOOR W/ SET XP DET. 3/S2 JOISTS W/ LB210 W/ (6) 10dX1-1 /2" TYP. CONNECT LEDGER W/ (2) I SDS25500 INTO 2X @ 24" O.C. NEW 2X10 FLOOR JOIST Q 16" JOIST OI JNEW4XIO BEAM' ; NEW4X10 BEAM �LL4-1 N 7 Z JOIST ®�1 NEW 2X10 FLOOR JOIST @ 16" OC. cl PT 4X4 W/ABA44Z N (OR SIMILAR) W/ (6) 10d & (1)? AB INTO 24" 0 X 36" DEEP CONC. FTG W/ (2) #4 REBAR EA. WAY (TYPICAL @ PORCH) I I I I I I EXISTING STRUCTURE NOT PART OF I ANALYSIS I I I I I EPDXY HOR. REBAR ',...� INTO X. FOUNDATION REF. " DET. 3/S2 I i I I : 1 NEW 4X10 BEAM I I I I 4X4 W/(2)AC4 @ EA.TOP W/(16)16d EA., & W/ ABA44Z @ BOT. EA. W/ (6)1 Od EA & (1) ? AB INTO 27"X27"X10" GONG. FTG. W/ (3) #4 REBAR EA. WAY v CONNECT W/ LUSC46 W/ (8) 1 S (TYP) PT 2X8 DECK JOISTS @ 16" O.C. A2FOUNDATION REVISION PER OWNER 02/21/2017 FOUNDATION & 1ST FLOOR FRAMING PLAN SCALE: 1/4" = 1' - 0" 1/2 El 2/2 F-07 T07- GAUTHIER SITE PLAN EX WATER METER EX SIDEWALK EX WATER SERVICE LINE a' y / O o l >8S8 „O D AREA OF ADDITION A=370 SF C.`. COVERED PATIO C oo ' DS co rye° DS PARCEL NUMBER 416790-0160 AREA = 10,200 SF TOPOGRAPHIC NOTE: THE EXISTING TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, TLD, LLC CANNOT ENSURE ITS ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. SILT FENCE W W Q W col>CL ?> O NO TREES TO BE cic L REMOVED OR ADDED a o Q AS PART OF ADDITION Z +-. E PROPOSED W� d�-M3 OWNSPOUT DRAINS R � X Q Q o O N TO EX. ROOF SYSTEM _J J m O Q EX RESIDENCE MAIN DSNORTH kDDS HALF `i W FF = 160 DRAINS TO EX. SOUTH HALF FLOOR FF = 166 BASEMENT FF = 157 R SW 307TH ST U) Lu Lu U) N N S C 4� SITE W W Q W col>CL ?> O cic L VICINITY MAP a o Q Z +-. W� d�-M3 R � X Q Q o O N NO SCALE _J J m O Q 2 e O M \ EX DRIVEWAY `i W Ds-_ m� VICINITY MAP ^p NO SCALE \ EX DRIVEWAY ,\ _ DRAINS TO EX. INFILTRATION TRENCH N 0 >00 DS DSS l o 9Se� AREA OF EX RES FOOTPRINT } w BUILDING SETBACKA=1550 SF Q m LINE (TYP) J00 Z W LLJ SCALE. 1"=20 FEET LL 06 M o. W LL W. Oc~i) am 0 20 40 0�6' O y >j, Q "' VERTICAL DATUM c+) KING COUNTY AERIAL 1- W N m c � Z 3 �p 4 HORIZONTAL DATUM KING COUNTY ASSESSOR MAP O < e, III � r e ' DEC 082016 D_ (D N a --LZHEET 1 OF 1x ' _