10-101172City of Federal Way 0
Community Development Services
• P.O. Box 9718
Federal Way, WA 98063-9718
Ph: (253) 835-2607 Fax: (253) 835-2609
Project Name: WOOD
Project Address: 426 SW 347TH ST
*uilding - Single Family
Permit #: 10 -101172 -00 -SF
Inspection Request Line: (253) 835-3050
Parcel Number: 132172 0220
Project Description: ADD - Construction of a 528 sqft detached covered patio. Includes plumbing and
mechanical.
Owner
AApglicant
Contractor
Lender
DOUG & STACY WOOD
AMERICAN DREAM DESIGN
AMERICAN DREAM DESIGN
DOUG & STACY WOOD
426 SW 347TH ST
BUILD
BUILD
426 SW 347TH ST
FEDERAL WAY WA 98023
4726 112TH ST E
AMERIDD933DE (3/6/11)
FEDERAL WAY WA 98023
TACOMA WA 98446
4726 112TH ST E
TACOMA WA 98446
Census Category: 434 - Residential alt/add - no change in number of units
Includes:
# 1 42 #3 #4
Occupancy Class:
R-3
Construction Type:
Type V - B
Occupancy Load:
Floor Area (sq. ft.)
528 1 0 1 0 1 0
11M�iE'llt0tfp aIN
F
New/ Additional Sq. Feet - I st Floor .................... 0 New / Additional Sq. Feet - 2nd Floor....... .........0
New / Additional Sq. Feet - 3rd Floor....................0 Occupancy #I - Area (Sq. Feet) ............................. 528
New / Additional Sq. Feet - Basement...................0 Occupancy # 1 -Construction Type ........................ Type V - B
New / Additional Sq. Feet - Deck..........................0 New / Additional Sq. Feet - Garage ....................... 0
Mechanical to be Included?....................................Yes Occupancy # 1 - Class ............................................. R-3
New/ Additional Sq. Feet - Other ..........................528 Plumbing to be Included? ....................................... Yes
New / Additional Sq. Feet - Total .......................... 528 Occupancy # I - Use ............................................... Residence (1 or 2
family)
Zoning Designation................................................RS 7.2
ti
Vechanical l'lxture5p 4011,
Fireplace Inserts ............................. 1 Gas Pipe Outlets............................. 2
x wRV
3
1i11itrllitil"(Xtt[1li3s?.
Dishwashers................................... 1 Sinks............................................... 1
PERMIT EXPIRES Saturday, October 9, 2010
Permit Issued on Monday, April 12, 2010
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington
/ an the City of Federal Way.
Owner or agent: ✓ ';! c. Date: �/
2 arc
F7N4QZD
G/silo
• THIS CARD IS TOOMAIN ON-SITE
CITY�Construction Inspection Record
Federal Way INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 10 -101172 -00 -SF Address: 426 SW 347TH ST
Owner: DOUG & STACY WOOD FEDERAL WAY, WA 98023-8352
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
E]
SWM Precon Site Mtg (4400)
Initial Erosion Control (4365)
❑
Footings/Setback (4110)
Plumbing Groundwork (4190)
Approved
Approved to place concrete
To be done prior to breaking ground
Approved to place concrete
By
Date
By
Date
By
Date
E]
Foundation Wall (4115)
❑
Drainage/Downspout (4040)
E:]
Plumbing Groundwork (4190)
Right of Way
Approved
Approved to place concrete
Date
Approved to backfill
Date
Approved to cover
By
Date
By
tj Date S_ /,? ld
By
Date a—<
Slab/Concrete Floor (4255)
E]
Underfloor Framing (4285)
E]
Floor Sheathing (4105)
Approved to place concrete
Approved to sheath floor
Approved to install flooring
By
Date
By
Date
By
Date
Shear Walls (4245) E:] Roof Sheathing (4220)
Approved to install siding Approved to install roofing
By Date By G tJ Date !/- ze -/Q rBy
Mechanical Rough -in (4165)Gas Piping (4125)
Approved Approved to release test
By Date By G Date _ 2� By
Rough Plumbing (4230)
Approved
r Date
Fire/Draft Stops (4095)
Approved
Date
Framing (4120)
Approved to insulate
By �jr Date /0
E] Final Erosion Control (4375)
Approved
By Date
Final - Mechanical (4065) ❑ Final - Plumbing (4075) ❑ Final - Building (4050)
Approved Approved Approved
Date �!� ( U By -YC-- Date Date
Rough Electrical
Approved
Final Electrical
Approved
®
Right of Way
Approved
By
Date
By
Date
By
Date
Bulletin #100 —January 1, 2010 Page I of 4 kAflandoutsTermit Application
• r J
" +1W
ue of Mechanical Work $ L�, /"C9 L% (A COPY OF BID OR ESTIMATE MUST BE
cate number o each type q^xture to be installed or relocated as part of this project. Do not include e�
AIR HANDLING UNITS FANS GAS PIPE OUTLETS _
AIR CONDITIONER FIREPLACE INSERTS HOODS (C-ria4
BOILERS FURNACES HOT WATER TANKS (cam)
COMPRESSORS GAS LOG SETS REFRIGERATION SYS`r
DUCTING GAS PIPING WOODSTOVES
rixtures to remain.
OTHER (Describe)
TENANT AREA ONLY
Bulletin #100 —January 1, 2010
Page 2 of 4
U11andoutsTemiit Application
(� YFB'� •ssf"
I
_ 9
ev
vl3Ttti'e2-Ihl: cNE'J
�n
6� N I Y 1= -� I i f 1\ m � I �� -- _ 2-��w'3— tee--;• - -�
( ( --Exl Awa pESlve �E - 11� PR (I n
!j I i I I) �Ws7� ��+ 1 1t�¢�H s 4954 kevlsEls IFJ P�evl hA
W
r I P 11ETo xlsT�y _ 1 S�c a,Nsz Tw.u�4 I P>Zv} 2, c Nc PAT reµ 4 to '�y.:. ._..
]PI 1Ni5 T—�
es
2373 5,17121,15
EX caN�
}0.5
I�� hl•1"E PLhI—1 - 0
-01
_. PAIulSL 1-19'. .132. 17?�.-22d '
RECEIVED
MAA 2 2 2010
CUS
�ur�� 15 -LEI F-1
�noveo cv � 0 2 S
RR