12-101947 41rt. Electrical City of FederalWay Permit #: 12-101947-00-EL Community Econ.& Dev.Services 33325 8th Ave S Federal Way,WA 98003 Ph:(253)835-2607 Fax:(253)835-2609 Inspection Request Line: (253)835-3050 eg Project Name: FRED MEYER t Project Address: 33702 21ST AVE SW Parcel Number: 930100 0010 Project Description: Adding/altering(1)circuit in shoe department location Owner Applicant Contractor FRED MEYER INC COCHRAN INC COCHRAN INC PO BOX 42121 PO BOX 33524 COCHRI*088JS(4/11/14) PORTLAND OR 97242 SEATTLE WA 98133 PO BOX 33524 SEATTLE WA 98133 Additional Permit information Is Use Educational or Institutional? No Service greater than 999 Amps? No Electrical Fixtures Circuits-Commercial 1 PERMIT EXPIRES Monday, October 29, 2012 Permit Issued on Wednesday, May 2, 2012 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington • and the City of Federal Way. Owner or agent: ^-, � Date: 5/2 / f 7:0 rig 1/.., THIS CARD IS TO MAIN ON-SITE CITY OF - Construction In ection Record ' Federal Way INSPECTION REQUE TS: (253)835-3050 PERMIT#: 12-101947-00-EL Address: 33702 21ST AVE SW Project: FRED MEYER INC FEDERAL WAY, WA 98023-7762 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 UFER Ground (4295) El Ditch cover(4030) -❑ Slab/Concrete Floor(4255) Approved Approved Approved to place concrete By Date By Date By Date '0 Pool Bonding(4195) �El Temporary Power(4275) ❑ Service(4235) Approved Approved Approved By Date By Date By Date ❑ Feeders/Sub-panels(4045) El Rough Electrical(4225) El Ceiling Cover(4020) Approved Approved Approved By Date By Date By Date . in., Final-Electrical(4055) Approved Dat ^�� r El Rough Electrical Final Electrical GI Right of Way Approved Approved Approved By Date By Date By Date i 2_ _ IC) I 9 z(' -- CITY OF A � Federal Way ELECTRICAL PERMIT APPLICATION MAY 0 220(2_ **Most electrical 'emits ma be obtained on-line at www.ci 01 odors wa� .Com E RA L WAY SITE ADDRESS: 33702 21st Ave SW Federal Way, W 98023 UQrts/Wart/$PACs a AaapIOR'$TAX/PARCZL a CORRZHT/PR(NOI WMM N/A _ Retail Store PROJECT NAME (Tenant or Homeowner Last Name) Fred Me er Store 111 PROJECT DESCRIPTION Detailed description of work to be included on this permit only PIUTLAITT nom PROPERTY OWNER -. _ ( 253 ) 952 - 0133 MAILING AMNMlas s-TTAM. N/A 33702 21:t Ave SW CITY STATIC VP 16111111EMII Federal Wa WA 98023 HAIR PROUR!PHOHs i1250Cochran,Inc 206 ) 367 - 1900 MAKING ADOSISS s MAIL ELECTRICAL 0 Aurora Ave N N/A i' / CONTRACTOR CRY zu. FAX Seattle 98133 ( 206 388 - 3197 WA STATIC CORTIRACTOM'S Lt`Canis a aZIPI tATIOM OATS TIDAL WAY SVOWI IS LlattISS a COCHRI.088JS 04/ 11 /2014 19-98-105630-00-BL HAMIC PRIMARY MONS Barbara Trochmann ( 206 ) 923 - 7655 APPLICANT MAaao MINIMS Z-MAtL 12500 Aurora Ave N •trochmann®cochraninc.Co CITY STATIC ZIP FAX Seattle WA 98133 ( 208 ) 368 - 3197 HAMS PRiftAlat PHONIC PROJECT CONTACT Tom Irwin ( 206 ) 498 - 2275 I cerilljl under penalty ofpsrjury that I ant the property owner or authorised agent of the property owner.I cet{Jy that to the best el my knowledge,the hybnmation aiwltted in support of this permit application is true and cornet.I cert{ty that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance q/a permit.I understand that the issuance of this permit does not remove the owner's responsibility Jbr compliance with local, state, or federal laws regulating construction or entimmnental lams. I,featiur agree to held hanmlau the City a/pederal Way as to any claim(including cams.expenses.and attorneys'Jbss incurred in the trmestigaNsn and dafetae q/such Maine.which may be mad*by any pest.including the mrederstgned.and filed agdtmt the city. but only when such claim arises out q/the reliance qj the city, including its gainers and employees. upon the accuracy b•the i.yb m ation supplied to time as /f this application. 7 \\!\;\ ) sIt}P(xruna he/A, '' �! i\N DATE 5/2/12 PRINT MAUL Barbara J. Tror1rtiu n —M 33325 8th Avenue South•Federal Way•WA♦98003-6325•253-835-26071 fax:253-835-26091 www.cityotfederatway.com Bulletin#160—January 1,2011 Page 1 of 2 k:Handouts\Electrical Permit Application . i t RESIDENTIAL COMMERCIAL. NEW SINGLE FAMILY RESIDENCE NEW COMMERCIAL Total Square Feet 1st Service/Feeder Additional Feeders (including attached garage): 0- 100 amp x$132.50 x$ 80.50 FEES: First 1300 ft2-$122.00: 101- 200 amp x$164.00 x$103.50 Each additional 500 ft2-$39.00 201- 400 amp x$307.00 x$121.00 NEW MULTIFAMILY(3 units or more) 401- 600 amp x$358.00 x$143.50 1 u Service/Feeder Additional Feeders 601- 800 amp x$463.00 x$196.00 0- 200 amp X $132.50 x $ 39.00 801-1000 amp x$565.00 x$236.50 201 -400 amp x $164.00 x $ 80.50 Over 1000 amp x$616.00 x$328.50 401-600 amp x $224.00 x $111.50 601 -800 amp x $287.00 x $153.50 Over 600 volts surcharge x$103.50 Over 800 amp x $410.50 x $307.00 ALTERED,SINGLE or MULTI FAMILY All,TERED COMMERCIAL 1 Service/Feeder 1t Service/Feeder Additional Feeders 0- 200 amp x $101.00 0- 200 amp x$132.50 x$103.50 201 -600 amp x $164.00 201- 600 amp x$307.00 x$121.00 Over 600 amp x $246.50 601-1000 amp x$463.00 x$196.00 Over 1000 amp x$515.50 x$328.50 Added or Altered Circuits 1-4 circuits$80.50;each additional$8.00 Added or Altered Circuits 1-5 circuits$103.50;each additional$8.00 Mast or meter repair $60.50 Mast or meter repair $111.50 MANUFACTURED HOMES PLAN REVIEW FEES Service or feeder only x $ 80.50 Plan Review required only for: Service and feeder x $132.50 • New,or alteration to,service of 1,000 amps or greater • Medical/Educational/Institutional Facility $103.50 plus 35%of Permit Fee (Permit Fee x 35% +$103.50=Plan Review Fee) Plan review for modified submittals $105.50/hour MISCELLANEOUS SERVICE/EQUIPMENT LOW VOLTAGE TEMPORARY SERVICE D Fire Alarm System 1st Service/Feeder Additional Feeders D Security Alarm System O voice/Data Cabling 0- 60 amp x $ 71.00 x $ 32.00 O Other 61-100 amp x $ 80.50 x $ 39.00 Area to be served by system: 1M 2,500112-$71.00;each additional 2,500 ft2-818.50 101-200 amp x $103.50 x $ 51.00 201-400 amp x $121.00 x $ 60.50 it of Thermostats 401-600 amp x $164.00 x $ 80.50 First$60.50:each additional$18.50 Over 600 amp x $184.50 x $ 92.00 FEE CALCULATIONS Yard Tole/metes loops/pedestal x$ 80.50 • Fees are determined by the scope of work as indicated. Portable Generator(transfer equipment) x$101.00 • A$6.00 Automation Fee will be added to all permits. Diteh cover/inspection only x$121.00 • For assistance in calculating fees or completing the application form,contact the Permit Center at 253435.2607 33325 8'h Avenue South•Federal Way•WA♦98003-6325•253-835-2607•fax:253-835-2609•www.cityoffederalway.com Bulletin#160-January 1,2011 Page 2 of 2 k:\HandoutsWlectrical Permit Application