15-106276 - Building.//.. - Commercial City o&Federal.Dev. y S Permit #: 15-106276-00-CO Community&Econ.Dev.Services 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253) 835-3050 Ph:(253)835-2607 Fax (253)835-2609 p q Project Name: FREEDOM FITNESS Project Address: 1320 S 324TH ST Unit A-Ill Parcel Number: 150050 0070 Project Description: TI-Interior tenant improvement work to include construction of partition walls to create offices, restroom and storage space.Plumbing and mechanical by separate permits. Owner Applicant Contractor Lender FREEDOM FITNESS INC TERESA FORTINO VELOTTA CONSTRUCTION CO OWNER IS LENDER 15830 1ST AVE S SUITE B-107 HELIX DESIGN GROUP INC BURIEN WA 98148-3305 6021 12TH ST E VELOTCC053N8(9/27/16) TACOMA WA 98424 100 290TH AVE SE FALL CITY WA 98024 Census Category: 437 - Commercial alt/add/conversion Includes: #1 #2 #3 #4 Occupancy Class: A-3 Construction Type: Type V-B Occupancy Load: 76 Floor Area(sq.ft.) 4,324 0 0 0 Additional Permit Information Building Pre-con.Meeting Required? No Existing Sprinkler System in Building? Yes Mechanical to be Included9 No Number of Stories 1 Permit for Building Shell Only9 No Plumbing to be Included? No Proposed Structure Valuation 140000.00 Special Inspection(s)Required9 No New/Additional Sq.Feet-Total 0 Occupancy#1 -Use Gymnasium No Fixtures Associated With This Permit !! PERMIT EXPIRES Saturday, August 27, 2016 Permit Issued on Monday, February 29, 2016 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use w be in accordance with the laws, rules and regulations of the State of Washington • • of Federal Way. Owner or ageitt>._. �' 1�� Date: ,-2 7 /(/ C.M.. _ TE INSPECTOR AREA AND TYPE OF INSPECTION “2;,---(0 fy. ,A, --51A \)/ -- .- cr IA , � � ,X , -z5--ILS ® ' THIS CARD IS TO REMAIN ON-SITE CITY OF Construction Inspection Record Feder 1 Way INSPECTION REQUESTS: (253)835-3050 PERMIT#: 15-106276-00-CO Address: 1320 S 324TH ST Unit A-111 Project: FREEDOM FITNESS INC FEDERAL WAY, WA 98003 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 Initial Erosion Control(4365) D Footings/Setback(4110) ElRe-steel(4215) To be done prior to breaking ground Approved to place concrete Approved to place concrete or grout By Date By Date By Date El Slab/Concrete Floor(4255) 0 Underfloor Framing(4285) El Floor Sheathing(4105) Approved to place concrete Approved to sheath floor Approved to install flooring By Date By Date By Date ' 1-1 Fire/Draft Stops(4095) ❑ Interim Erosion Control(4370) ,'''''' " .,,,,m g. (MI — Prior to scheduling a Frmiang inspection; Approved Approved Electrical,Plumbing&Mechanical Rough-in and Fire/Draft Stop inspections must be signed-off and By Date By Date approved. IBC 109.3.4 El Framing(4120) [I-fl Insulation (4150) ❑Gypsum Wallboard Nailing(4130) Approved to insulate Approved to install wallboard Approved to install mud&tape B Date _Z (_ 6, ��,_,__-- Date _„--_--7- _ (/, By kj Date 3130( it. Suspended Ceiling Grid (4265) 0 Final- S KF&R(4060) El Final-Planning Approved to drop tile Approved Approved By Date By . Date By Date Final Erosion Control(4375) El Final-Building(4050) Approved Approved By Date By �� Date 3 N.--1 ka • ❑ Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date P^: EN(,, March 16, 2016 Paul Velotta Velotta Construction Co., Inc. 100 290th Avenue SE Fall City WA 98024 RE: Freedom Fitness Exterior Stud Wall Evaluation,Federal Way WA Dear Paul: PSM, Inc. completed a site visit to review concerns of the north exterior wood stud wall framing at a future Freedom Fitness site (1320 S 324th Street,Federal Way WA). The intent of this letter is to provide documentation and a summary of our review, including conclusions based on visual observation and recommendations regarding repairs if necessary to restore the north wall. The purpose of our site visit was to examine the existing conditions of the north wood exterior wall framing and to provide a structural repair solution if needed. The existing building structure consists of a Berkley type roof framing system with exterior wood perimeter walls. The existing exterior north wall construction consists of plywood sheathing, 2x6 wood studs, &wood header beams at door openings. The wall is supported below on the existing concrete foundation footing. The exterior north wall in question supports 3ft. of tributary roof framing. Photo shows partial north wood wall 171 woof framing. Damage occurs at 1 numerous wall studs. Damage to studs consists of prior notches and bored holes at various locations along the height of the studs. Ten stud framing locations of the exposed wall framing were identified as needing to be repaired. The studs in question were marked while on site and are to be repaired as recommended. 2200 6TH AVENUE, #601 WWW.PSM-ENGINEERS.COM PHONE 206-622-4580 SEATTLE WASHINGTON 98121 USA FAX 206-622-0422 J Ad • Recommended Repairs: Ten stud framing locations (numbered and identified while on site) are to be repaired. The following is a summary of the existing framing per location and the recommended repair for each location. All new lumber to be added shall be Douglas-Fir Type#1 material. -Stud Framing Location#1 Existing Framing: DBL 2x6 studs are not fully supported at base and a number of existing bored holes. Recommended Repair: Add 2x bearing blocking around PVC piping at bottom of wall and add Simpson MSTC66 strap from the added bearing blocking to existing stud. -Stud Framing Location#2 Existing Framing: Single 2x6 stud is not fully supported at base and a number of existing bored holes near toward the interior face of wall. Recommended Repair: Add partial height 2x4 at each side of existing stud. The new 2x4s are to be against the existing plywood and should be nailed to the existing framing with (2)l Od nails at 6"oc. -Stud Framing Location#3 Existing Framing: Double 2x6 stud has a number of notches and (4) existing bored holes. Recommended Repair: Add partial height 2x4 at each side of existing studs. The new 2x4s are to be against the existing plywood and should be nailed to the existing framing with (2)10d nails at 6"oc. -Stud Framing Location#4 Existing Framing: Triple 2x6 stud has a number of notches and existing bored holes. (2) of the existing studs are not fully supported at the base. Recommended Repair: Add 2x bearing blocking at base. Add partial height 2x4 at each side of existing studs. The new 2x4s are to be against the existing plywood and should be nailed to the existing framing with (2)l Od nails at 6"oc. • 'r -Stud Framing Location#5 Existing Framing: Double 2x6 stud has a number of notches and existing bored holes. (1) of the existing stud is not fully supported at the base. Recommended Repair: Add 2x bearing blocking at base. Add partial height 2x4 at each side of existing studs. The new 2x4s are to be against the existing plywood and should be nailed to the existing framing with (2)l Od nails at 6"oc. -Stud Framing Location#6 Existing Framing: Double 2x6 stud has a number of notches and existing bored holes. Recommended Repair: Add partial height 2x4 at each side of existing studs. The new 2x4s are to be against the existing plywood and should be nailed to the existing framing with (2)l Od nails at 6"oc. -Stud Framing Location#7 Existing Framing: Single 2x6 stud with 2x4 blocking has numerous notches and bored holes. Recommended Repair: Add partial height 2x4 at each side of existing studs (Flat side of 2x along face of existing plywood). The new 2x4s are to be against the existing plywood and should be toe-nailed to the existing framing with (2)l Od nails at 6"oc. -Stud Framing Location#8 Existing Framing: Single 2x6 stud with 2x4 blocking has numerous notches and bored holes. Recommended Repair: Add partial height 2x4 at each side of existing studs (Flat side of 2x along face of existing plywood). The new 2x4s are to be against the existing plywood and should be toe-nailed to the existing framing with (2)l Od nails at 6"oc. -Stud Framing Location#9 Existing Framing: Single 2x6 stud with 2x4 blocking has numerous notches and bored holes. Recommended Repair: Add partial height 2x4 at each side of existing studs (Flat side of 2x along face of existing plywood). The new 2x4s are to be against the existing plywood and should be toe-nailed to the existing framing with (2)10d nails at 6"oc. ' : >8 lI 'it -Stud Framing Location#10 Existing Framing: Double 2x6 stud blocking has numerous notches and bored holes. Recommended Repair: Existing piping is to be moved away from this location. Add partial height 2x4 at each side of existing studs (Flat side of 2x along face of existing plywood). The new 2x4s are to be against the existing plywood and should be toe-nailed to the existing framing with (2)10d nails at 6"oc. Framing locations and recommended repairs were communicated to General Contractor while on site and are to be installed as recommended. Please contact us for any questions or clarifications. ,,J4 -f4. Sincerely, vihVID sr PSM, Inc. G 01.WAS,r . ,i7.A...gler,re ir"------ 4 4,. , , , ,. _ . _ i„ .., _. „.„ .,..„ . , -, . ..„ ,. , Robert Cruz, P.E. lA Project Manager • 0 111C1,::01F PER Mg! Federal Way V DEC 112015 5 z7(:-,i. 1 7 J 5 FEDERAL WAYPERMIT NUMBER — _ — _ _ CDGET DATE SITE ADDRESS SUITE/UNIT# 1 Sao 4. 38,4-- ) 44- A- -1. i i PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# $ ► 01000 8N t 6 0 0 5 0 _ o o 7 0 TYPE OF PERMIT ❑ BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT fi/,G m ) :7 ./7)C ��- PROJECT DESCRIPTION p. =4". .�f L A4•4_. ..� 1t.lAl� Detailed description of work to • be included on this permit only NAME PRIMARY PHONE Pfl �o� a�� • s�oo PROPERTY OWNER MAILING A D RSS E-MAI SSS u Int �d• 4 /a 7 CIT • SigA ZIP_/ / ! g PHONE NAME �5- ,,,IN MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# ���///��� `y'• / / A 1 I�, Q NA HONE //l / /O''t/ . -/D 3 7 APPLICANT M ILING ADDRmth 4.. E-MAIL CITE-+ l) AjfE ZIP _ ji. FAX PROJECT CONTACT NAME 7- t.- /A._ i�G�/ "r'n PR I 3�v i O - 7D 71 (The individual to receive and AILING ADDR S ifflAi/1/Iµ�, eh -aM/AIL'� respond to all correspondence706al ��� siC��x :����y •44 concerning this application) J,�'3i XtIn)' sTgT>� zI oty. FAX NAME �� PROJECT FINANCING ❑ OWNER-FINANCED Required value of$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs, expenses, and attorneys'fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. , l SIGNATURE: a� kixidiyr DATE /v / / /S PRINT NAME: 7-ere-Qt.- I J kV Bulletin#100—October 26,2015 Page 1 of 3 k:AHandouts\Permit Application 'MECHANICAL t S VALUE OF MECHANICAL WORK MECHANICAL PERMIT •�, S $ Indicate how many ofeach type of fixture o be installed or relocated as part of this project. Do not include existing fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER(Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS(Commercial) BOILERS FURNACES HOT WATER TANKS(Gas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMITDq-64-Kel, $ Indicate how many of each type offix re to be installed or relocated as part of this project. Do not include existing fixtures to remain. BATHTUBS(or Tub/Shower Combo) LAVS(Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS(Kitchen/utility) WATER HEATERS(Electric) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS .1rao /Wildit t7r0t&ho U4i4 *10, 500 EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? 1(.tM2 44i. 'las I /' r. XYes ❑ No ❑Yes$iNo RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BASEMENT FIRST FLOOR(or Mobile Home) SECOND FLOOR COVERED ENTRY DECK GARAGE ❑ CARPORT ❑ OTHER(describe) EXISTING PROPOSED TOTAL Area Totals **NEW HOMES ONLY** ESTIMATED SELLING PRICE$ # OF BEDROOMS COMMERCIAL—NEW/ADDITION AREA DESCRIPTION Area in Occupancy Group(s) Construction #of Additional Information Square Feet Type Stories NEW BUILDING ADDITION COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in Occupancy Group(s) Construction #of Additional Information Square Feet Type Stories TOTAL BUILDING 0146/ 26` TENANT AREA ONLY Ott 3913A 03 ' '�l PROJECT AREA ONLY k (/it A3 Ve I Bulletin#100—October 26,2015 Page 2 of 3 k:\Handouts\Pemiit Application