09-103931•� 4
City of Federal Way
Community Dev lopment Services
P.O. Xx 9718
Federal Way, WA 98063-9718
Ph (253) 835-2607 Fax: (253) 835-2609 FILE
Project Name: MING COURT LOT 4
Project Address: 612 S 310TH CT
`Building - Single family
Permit #: 09 -103931 -00 -SF
Inspection Request Line: (253) 835-3050
Parcel Number: 554760 0040
Project Description: NEW - Construct a 2,095sgft single family residence with attached 489sgft garage and
52sgft covered entry porch. Plumbing and mechanical included. ***4 Bedrooms; Estimated
selling price $285,000.
Basic# 09-103190
Owner
Applicant
Contractor
Lender
NORRIS HOMES INC
NORRIS HOMES INC
NORRIS HOMES INC
BANK OF AMERICA
2053 FABEN DR
2053 FABEN DR
NORRIH1099LC (5/22/11)
10500 NE 8TH ST SUITE 400
MERCER ISLAND WA 98040-2001
MERCER ISLAND WA 98040-2001
2053 FABEN DR
BELLEVUE WA 98004
Yes
MERCER ISLAND WA 98040
Type V - B
Census Category: 101 - New Single Family House
Includes:
# 1
#2 #3 #4
Occupancy Class:
R-3
U
Construction Type:
Type V- B
Type V- B
OCCu ancy Load:
Occupancy 42 - Area (Sq. Feet).............................489
Floor Area (sq. f.)
2,147
489 0 0
Additional Permit Information
New/ Additional Sq. Feet - 1 st Floor ....................
973
New/ Additional Sq. Feet - 2nd Floor ...................
1174
New/ Additional Sq. Feet - 3rd Floor....................0
Occupancy # 1 - Area (Sq. Feet) .............................
2147
Occupancy 42 - Area (Sq. Feet).............................489
New / Additional Sq. Feet - Basement ...................
0
Basic Plan?...........................................................
Yes
Occupancy # 1 - Construction Type ........................
Type V - B
Occupancy #2 - Construction Type ........................Type
V - B
New / Additional Sq. Feet - Deck ..........................
0
New/ Additional Sq. Feet- Garage .......................489
Mechanical to be Included?...................................
Yes
Number of Bedrooms.............................................4
Total Number of Dwelling Units ...........................
1
Occupancy # 1 - Class ........................................
)....
R-3
Occupancy #2 - Class.............................................
U
New / Additional Sq. Feet - Other ..........................0
Plumbing to be Included? .......................................
Yes
New/ Additional Sq. Feet - Total ..........................
2636
Occupancy #1 - Use...............................................
Residence (1 Or 2
family)
Occupancy #2 - Use ...............................................
Private Garage
Zoning Designation ................................................
RS 7.2
Mechanical Fixtures
Ducting...........................................
1
Fans................................................
5 Furnaces.........................................
1
Gas Piping ......................................
1
Gas Pipe Outlets.............................
1
Plumbing Fixtures
Bathtubs .........................................
2
Dishwashers...................................
1 Laundry Washer Outlets................
1
Lavatories .......................................
3
Sinks...............................................
1 Water Closets.................................
3
Water Heaters .................................
1
Hose Bibbs.....................................
2
r eN n
CONDITIONS:
1. Lot 4 roof downspouts on all lots shall be directly connected to the approved storm drainage system
stub -out, as shown on the as -built storm drainage plans, Sheet C8, City file #06 -102066 -00 -EN.
� t 6"� V �_C_%o z/ 5/I
PENIT EXPIRES Tuesday, April 6, 2O
Pe t Issued on Thursday, October 8, 20
0
i
I hereby certify that t'ea
ove information is correct and that the construction on the above described property and
the occupancy and the e will be in accordance with t aws, rules and regulations of the State of Washington
and t t Federal Way.
Owner or agent: Date:
Io-0"ol
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 110.2 of the International Building Code certifying that
at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building
construction or use. This certificate is valid ONLY when endorsed by City staff.
Tenant Name: MING COURT LOT 4
Address: 612 S 310TH CT
Permit #: 09 -103931 -00 -SF
Includes:
41
92 #3 #4
Occupancy Class:
R-3
U
Construction Type:
Type V- B
Type V- B
Occupancy Load:
Floor Area (sq. ft.) 1
2,147 1
489 0 0
Owner Name: NORRIS HOMES INC
Owner Address: 2053 FABEN DR
MERCER ISLAND WA 98040-2001
Building Official Date
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severly affect the health and safety of the general public. Although the City has made as complete a
review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor
warrants to the owner / occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which itis situated. Such compliance is the responsibility of the owner and/or occupant of the premises.
A, THIS CARD IS TO RI&AIN ON-SITE
CITY OF "' � �� Construction inspFction Record
Federal flay INSPECTION REQUESTS: (253) 835-3U50
PERMIT #: 09 -103931 -00 -SF �A4dress: 612 S 310TH CT
Owner: NORRIS HOMES INC FEDERAL WAY, WA 98003
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about am- of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
SWM Precon Site Mtg (4400)
Initial Erosion Control (4365)
E] Footings/Setback (4110)
Approved
To be done prior to breaking ground
Approved to place concrete
By Date
By Date
By-- Date
E] Foundation Wall (4115)
Approved to place concrete
By��� Date ()--2(-09
Slab/Concrete Floor (4255)
Approved to place concrete
By Date
Drainage/Downspout (4040)
Approved to backfill
By ate 01/0
Underfloor Framing (4285)
Approved to sheath floor
By -6 C-;;, Date t t _ Z _ 09
E] Plumbing Groundwork (4190)
Approved to cover
By Date
Floor Sheathing (4105)
Approved to install flooring
By Date `
E] RouIn
gh Plumbing (4230)
Approved
Byfilo-r-
Date
Ei N'ire/Draft Stc
Approved
BY . 7 Date
Framing (412,
Approved to insulate
By Date / Y//
El
Shear Walls (4245)
E] Roof Sheathing (4220)
Approved to install siding
Approved to install rooting
By
C Date t 1 ^ _
ByDate _ 1— C
Approved
Mechanical Rough -in (4165)El
Gas Piping (4125)
By l2 Date /2 cr�d
Approved
Approved to release test
By
G.. Date _ 44
By G Date//, 30 d
Final - Building (4050)
Interim Erosion Control (4370)
Approved
Prior to scheduling a Framing inspection;
Approved
I
Electrical, Plumbing & Mechanical Rough -in and
By
01"5 Date 112,1/ C
Fire/Draft Stop inspections must be signed -off and
approved. IBC 109.3.4
_ Date
V/,
E] Plumbing Groundwork (4190)
Approved to cover
By Date
Floor Sheathing (4105)
Approved to install flooring
By Date `
E] RouIn
gh Plumbing (4230)
Approved
Byfilo-r-
Date
Ei N'ire/Draft Stc
Approved
BY . 7 Date
Framing (412,
Approved to insulate
By Date / Y//
El
Insulation (4150)
Gypsum Wallboard Nailing (4130)
Final Erosion Control (4375)
Final Electrical
Approved
Approved to install wallboard
Approved to install mud & tape
Right of Way
Approved
Approved
ByDate
/2,31
By l2 Date /2 cr�d
By
Date
Final - Mechanical (4065)
Final - Plumbing (4075)
❑
Final - Building (4050)
Approved
Approved
Approved
By�r
Date `7
y Datel-9ld
By
_ Date
Rough Electrical
Approved
By Date
Final Electrical
Approved
Right of Way
Approved
Bye
Date b �. J
By
Date
4*�_ 103��
CITY of KE1 It [PERMI'T S MF CO ME EJ, PL DE EN FP
Federal W
CO253-835-2607- FAX 23-83sERvcF
5-2609 5� T O P A P P L I CATION
UR01L. (1!tl01fN.(1CTU�U'(lll. (`0111 '
SITE ADDRESS
612 S. 310th Ct.
SUITE/UNIT #
ZONING
ASSESSOR'S TAX/PARCEL #
RS7.2
5 5 4 7 6 0_ 0 0 4 0
PROJECT
NAME OF PROJECT
(Tenant or Homeowner Name)
Min Court Lot #4
g
XX BUILDING )0( PLUMBING XX MECHANICAL
TYPE OF PERMIT
❑ DEMOLITION ❑ ELECTRICAL ❑ ENGINEERING ❑ FIRE PREVENTION
New Contruction of a 2095 sgft. single family residence with attached 489 sqft garage, and 52 sqft
PROJECT DESCRIPTION
Detailed description of work to
covered porch, built from basic. 1160
be included on this permit only
BasicPlan # 0 — p1 Ct 0
F-OPLE
NAME
PRIMARY PHONE
PROPERTY OWNER
Norris Homes Inc.
( 206 ) 275 - 1901
MAILING ADDRESS, CITY, STATE, ZIP
E-MAIL
2053 Faben Drive Mercer Island, WA 98040
info@norrishomesinc.com
OWNER IS ALSO:
CONTRACTOR APPLICANT PROJECT CONTACT
NAME
Norris Homes Inc.
PRIMARY PHONE
( 206) 275 - 1901
CONTRACTOR
MAILING ADDRESS, CITY, STATE, ZIP
2053 Faben Drive Mercer Island, WA 98040
FAX
( 206) 275 - 1910
WA STATE CONTRACTOR'S LICENSE #
EXPIRATION DATE
FEDERAL WAY BUSINESS LICENSE #
NORRIH109LC
5 / 22 /2011
20 -06 -102905 -BL
NAME
PRIMARY PHONE
APPLICANT
Same
( _
MAILING ADDRESS, CITY, STATE, ZIP
/ FAX
1 )
PROJECT CONTACT
NAME
PRIMARY PHONE
(The individual to receive and
James Kerby
206 ) 275 - 1903
respond to all correspondence
concerning this application)
MAILING ADDRESS, CITY, STATE, ZIP
2053 Faben Drive Mercer Island, WA 98040
FAX
( 206 ) 275 - 1910
ALTERNATE CONTACT NAME:
PRIMARY PHONE
E-MAIL
Damian Norris
( :20:6 275 - 1907
james@norrishomesinc.com
PROJECT FINANCING
Required for projects with
NAME
Bank of America
❑ OWNER -FINANCED
value of $5, 000 or more
MAILING ADDRESS, CITY, STATE, ZIP
PRIMARY PHONE
(RCW 19.27.095)
10500 NE8th St., Suite 400 Bellevue, WA 98044-4351
( 425 ) 467 -9776
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the
best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply
with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that
the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I furtheragree t old harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred
in the investigation a d defense of such claim), which m y be made by any person, including the undersigned, and filed against the
city, but only where c hclaim arises out of the r of the city, including its officers and employees, upon the accuracy of the
information supplied to e city as a part of this p i on.
SIGNATURE: DATE 10-5-09
PRINT NAME. Damian Norris
Bulletin #100 — 9/15/2009 Page 1 of 4 k:\Handouts\Permit Application
00
•0
GENERAL INFORMATION
PROJECT VALUATION
MECHANICAL FIXTURES
PLUMBING
Value of Mechanical Work $
A COPY OF BID OR ESTIMATE MUST BE PROVIDED
Indicate number of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain.
0
AIR HANDLING UNITS 5
FANS 1 GAS PIPE OUTLETS 0 OTHER (Describe)
_0
AIR CONDITIONER 0
FIREPLACE INSERTS 0 HOODS (Commercial)
0
BOILERS 1
FURNACES 0 HOT WATER TANKS Gas)
_0
COMPRESSORS 0
GAS LOG SETS 0 REFRIGERATION SYST
ves
DUCTING j
GAS PIPING 0 WOODSTOVES
GENERAL INFORMATION
PROJECT VALUATION
WATER PURVEYOR
PLUMBING
FIXTURES
FOR OFFICE USE
_ ..........................
Indicate number of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain.
2
BATHTUBS or Tub/ Shower combo)
3
LAVS (Hand Sink,)
3 TOILETS yes WATER PIPING
1
DISHWASHERS
0
RAINWATER SYSTEMS
0 URINALS 0 OTHER (Describe)
0
DRAINS
0
SHOWERS
0 VACUUM BREAKERS
0
DRINKING FOUNTAINS
1
SINKS (Kitchen/Utility
1 WATER HEATERS (Electric)
2
HOSE BIBBS
0
SUMPS
1 WASHING MACHINES 14 TOTAL FIXTURES
GENERAL INFORMATION
PROJECT VALUATION
WATER PURVEYOR
SEWER PURVEYOR
VALUE OF EXISTING IMPROVEMENTS
FOR OFFICE USE
_ ..........................
BASEMENT
NEW BUILDING
EXISTING/PREVIOUS USE
v r-110
LOT SIZE (In Square Feet)
-1
EXISTING FIRES RINKLER SYSTEM?
❑ Yes No
PROPOSED FIRE SUPPRESSION SYSTEM?
❑ Yes V- No
e i iJ f
1. 0 5(���
SECOND FLOOR
Al
RESIDENTIAL
AREA DESCRIPTION (in square feet)
EXISTING
PROPOSED
TOTAL
FOR OFFICE USE
_ ..........................
BASEMENT
NEW BUILDING
FIRST FLOOR (or Mobile Home)
921
921
SECOND FLOOR
1174
1174
r
COVERED ENTRY
Area
in Square Feet
52
52
DECK
Additional Information
0
0
GARAGE XX CARPORT ❑
489
489
OTHER (describe)
Area Totals
EXISTING
0
PROPOSED
2636
2636
**NEW HOMES ONLY**
ESTIMATED SELLING PRICE $ 285,000
# OF BEDROOMS 4
COMMERCIAL - NEWIADDITION
AREA DESCRIPTION
Area
in Square Feet
Occupancy Group(s)
Construction
Type
# of
Stories
Additional Information
NEW BUILDING
ADDITION
COMMERCIAL - REMODEL/TENANT IMP'R'OVEMENTS
AREA DESCRIPTION
Area
in Square Feet
Group(s)
Construction
TypOccupancy
a
# of
Stories
Additional Information
TOTAL BUILDING
TENANT AREA ONLY
PROJECT AREA ONLY
Bulletin #100 — 9/15/2009
Page 2 of 4
k:\Handouts\Permit Application
R = 53,00'
L = 39.73'
SOUTH 31 OTH COURT
DIA. RIGID ROOF DRAIN TYP.
DNNECTTO APPROVED
2AINAGE SYSTEM.
Impervious Surface Calculations
Lot area
7204
SQFT
Building Area
1462
SQFT
Lot Coverage
20.3
%
Otherimperv.
sae
SOFT
Total lmperv.
27.9
%
Max. lmperv.
60.
Verifyerosion control
measures
Ming Court Lot# 4 ;
Scat : i=20'
,ZONING: RS7.2
NOTES
612 S. 310th Ct. - PFcl# 554760-0040
Date: 10-7-09
Setbacks
I.
Verify garage is inline w/
Rev:
Front: 20
0Cn
(n
approach
f r■ N O R R I S 2853 Faben 8rive
Mercer Island, WA 98840
Rev:
Drive: 20'
Rear. 51
2,
Verifyerosion control
measures
Tel 205.275.1901
� � ®
0 M B
Side Int.: 5
Side St.: Id
3.
Field check all
H O M E S norrishomesinc.com
By:Domian Norris
OCT 0 7 2009
measurements
l
I
it
I
i
l
I
a>
D
O 0 7J
m �Do_:
0Cn
(n
C)Sa°�o;
OGi�(no
0 M B
C a:.
RECEIVED
C7 0
OCT 0 7 2009
"
CITY OF FEDERAL WAY
CDS
I