Loading...
02-101076 1 '.... w 1 ;� . 'City G't.de.a.Way Building - Commercial Permit #:02 - 101076 - 00 - CO Community Development Services 33530 1st AA'av S Federal Way,WA 98003-6210 I l'h:253.6',I.4000 Fax:253.661.4129 i Inspection request line: 253.835.3050 Project Name: SOUTH CAMPUS BIBLE FELLOWSHIP CHURCH Project Address: 1336 S 336TH Parcel Number: 926503 0040 Project Description: TI-Interior alterations; includes plumbing and mechanical work. Change use from office to church and occupy,per plans. Owner Applicant Contractor Lender T L C ENTERPRISES BIBLE FELLOWSHIP R D'S WATER DAMAGE&CONSTI BIBLE FELLOWSHIP 714 ROSE ST PO BOX 4676 RDSWADC033KO 5/20/02 PO BOX 4676 FIRCREST WA FEDERAL WAY WA 98063 PO BOX 23785 FEDERAL WAY WA 98063 98466-7232 FEDERAL WAY WA 98093 Includes: Census category: 437-Comm F #1 #2 #3 _,- #4 I—Occupancy Group: A-3 r 1 Construction Type: I Type V-N Occupancy Load: 294r L H — - Floor Area(Sq.Ft.): 8920 r L Census Category 437-Commercial alt/add Fire Sprinklers No Mechanical Yes Number of Stories I Permit for Building Shell Only No Plumbing Yes Will Certificate of Occupancy be Issued9 Yes Zoning Designation BC Plumbing Fixtures T Description [quantity Description "Quantit J i ` Description rduantitj [Lavatories 2 Water Closets �P 2 Mechanical Fixtures 'Ll Description Quantity Description _ �Quantit� Description jjQuantity Air I! ndling Units 33 Ducts I Fans 1 L J J CONDITIONS: Please call Jane Gamble at 253-661-4120 for final site inspection. All new and refaced signs require a separate sign application and review. (FWCC,Sec.22-335(g)(6)) PERMIT EXPIRES November 6,2002,IF NO WORK IS STARTED. Permit issued on May 3,2002 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws,rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Date: MIMI. I s moi. • • , (a , City or Federal Way . Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 109 of the Uniform Building Code certifying that at the time of issuance,this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: SOUTH CAMPUS BIBLE FELLOWS: Permit number: 02- 101076-00 Address: 1336 S 336TH #1 #2 I #3 #4 Occupancy Group: A-3 t ' Construction Type: Type V-N Occupancy Load 294 Floor Area(Sq.Ft.): 8920 I Owner T L C ENTERPRISES Name: 714 ROSE ST Address: FIRCREST WA 98466-7232 Building Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time and personnel limitations),the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. • 1 • 1110 INSPECTION LOG DATE INSPECTOR OK CORR/REJ AREA AND TYPE OF INSPECTION ✓ 4-5 S ),,. off` oz S ca.. eif-gh *di-) Wadi bMr1 ,r‘-± Ioyev oc erne) Jr, c'oyril oy iA 2 11 ¢rte L'/15 �h Uss/e. -4 . r� 41-414' 4,C5 e4 - ate_ vIyc,•// Q carr;LGt Uvaw (SCi cum ,0 1,,„() #;;,, elf 7- e 4-12-9 t"»10 Ce. L21 Ve R. ) 'oCG(u Q (,/ e(y 1/0•120 i AI EQ-4;l9A,,e,)le--X PP/11, ECiaPir ect -ta r ke_ s Ttbste s6�vw��✓ loAr - C-4%) 7 Iii F ua / o POS THIS CARD ON THE FRONT OF BUILDI G • BUI ilING DIVISION uv FlY INSPECTION RECORD INSPECTION REQUEST PHONE#: 253-835-3050 PERMIT #: 02-101076-00-CO OWNER'S NAME: T L C ENTERPRISES SITE ADDRESS: 1336 S 336TH () FOOTINGS/SETBACKS () FOUNDATION WALL -.mit 1)0 NOT POUR CONCRETE UNTILATHE ABOVE IS APPROVED ( ) DRAINAGE: Line ( ) Connection z h�. 3DO NOT POUR SLAB UNTIL THEarABOVE IS APPROVED: ( ) UNDERFLOOR FRAMING () ROUGH PLUMBING: DWV Water piping () ROUGH MECHANICAL 19� / 7 s. Gas piping () SHEATHING Roof Floor q/6`0 7� ( ) SHEAR WALLS () ELECTRICAL ROUGH-IN Ditch Cover ( ) FIRE/DRAFTSTOPS ALL THE ABOVE MUST BE APPROVED PRIOR TO FRAMING INSPECTION] () FRAMING/FIRESTOPPING `/�Z70 THE ABOVE MUST BE APPROVED PRIOR TO INSULATING OR SHEETROCKING `C () INSULATION: Floors Walls ✓5 Attic 4A ' THE ABOVE MUST BE APPROVED PRIOR TO APPLYING SHEETROCK WALLBOARD NAILING I0A/)Z_ ✓ OSUSPENDED CEILING r THE ABOVE MUST BE APPROVED,PRIOR TO TAPING OR INSTALLING CEILING;TILE () ELECTRICAL FINAL () PLANNING FINAL () PUBLIC WORKS FINAL ( ) FIRE FINAL THE ABOVE MUSTBBE APP 0 ED PRIOR TO BUI G DEPARTMENT FINAL O BUILDING FINAL / Z1 C— 7xz DO NOT OCCUPY THIS BUILDING UNTIL BUILDING FINAL IS APPROVED R CEIVED � .a , MAR 1 2 2002 CONSTRUC I ION PERMIT APPLICATION Fns APPLICATION NUMBER: b Z- (a ( © '76-®_C> —e VV FTY CITY OF FEDERAL WAY APPLICATION NUMBER: - BUILDING DEPT. - - APPLICATION NUMBER: - **The following is required information-Please print(hi ink)or type** ` Please note: Electrical, Fire Prevention Systems and Engineering permits may require a separate application. ■ PROPERTY INFORMATION , SITE ADDRESS: / Cie3� 4 . Lc 1S SI ASSESSOR'S TAX/PARCEL #: CI . (9• 0 ;� - O n 5% O '--(31 LEGAL DESCRIPTION OF SUBJWT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY): c I-- Z P/42.7 .3-73o(0-2 l� :<.` . -53.-, -:.....,•i:11::'PROJECT INFORMATION . TYPE OF PROJECT(This application): BUILDING L PLUMBING LNMECHANICAL ❑ DEMOLITION ELECTRICAL ❑ ENGINEERING❑ FIRE PREVENTION SYSTEM PROJECT DESCRIPTION (Provide detailed description): PROJECT NAME: ig.lhl� F1/oWc`,r-. ■;PEOPLE INFORMATION c.PROPERTY OWNER: NAME: �� al '` ` DAYTIME PHONE: - MAILING ADDRESS(STREET ADDRESS;CITY,STA ZIP): `/ `J 11;ej;(rOlk4 NTRA OR: NAME: ` DAYTIME PHONE: MAILING ^ADDRESS(STREET ADDRESS;CITY,STATE,ZIP7: EVENING PHONE: P `FEDERAL WAY -- NUMBER: W v� w� )• cit0.)3 (Z4 g)FAX ds- - Z 9 3 CITY6,I6 2-0-00 /9 - 71 - 4 -0 q 94 f - 0 O. (?s3) 5 - G rye CONTRACTOR'S REGISTRATION NUMBER: EXPIRATION DATE: (copy of card required) ` D 5 W K t) C C 3 K Q / 2--,:-, I C) APPLICANT: NAME: \, DAYTIME PHONE: SOO/-4 C�rw u.> ►3i biE- ��/�w5A-�,.2p ,Zs (05-5) $-1 Y - kz55067 MAILING ADDRESS(STREET A RESS,CITY,STATE,ZIP): EVENING PHONE PO 3d— (467(4 reb. virty. V14. 9go(3 ( ) - RELATIONSHIP TO PROJECT: FAX NUMBER: ❑ ARCHITECT LI TENANT ❑ OTHER(DESCRIBE): ( ) E-MAIL ADDRESS: CONTACT PERSON FOR THIS PROJECT: ❑ PROPERTY OWNER ❑ APPLICANT IK CONTRACTOR - •:a -DETAILED BUILDING INFORMATION EXISTING USE: %c.--�-�,, e EXISTING BUILDING ASSESSED/APPRAISED VALUATION $ PROPOSED USE: '`w `"� PROPOSED VALUATION FOR IMPROVEMENTS: $ /Z740 SPRINKLERED BUILDING? ❑ YES 71-NO FIRE SUPPRESSION SYSTEM PROPOSED/REQUIRED: ❑ YES ANO WATER SERVICE PROVIDER: igf,LAKEHAVEN ❑ HIGHLINE ❑ TACOMA ❑ PRIVATE(WELL) SEWER SERVICE PROVIDER: .LAKEHAVEN ❑ HIGHLINE ❑ PRIVATE(SEPTIC) **NEW RESIDENTIAL CONSTRUCTION ON� —' NUMBER OF BEDROOMS: ESTIMATED SELLING PRICE: $ • . ■ PROJECT FLOOR AREAS • FLOOR EXISTING SQ.FT. PROPOSED SQ.FT. TOTAL BASEMENT FIRST C12.•C) SECOND THIRD FOURTH OTHER FLOORS(DESCRIBE) DECK • GARAGE HOW MANY FLOORS? TOTAL: 12 ° ■ FIXTURES . Indicate number of each type of fixture MECHANICAL zDr dao AIR HANDLING UNIT(S) EVAPORATIVE COOLER(S) GAS LOG(S) REFRIG.SYSTEM(S) BBQ(S) FAN(S) HOOD(S) WOODSTOVE(S) BOILER(S) FIREPLACE INSERT(S) RANGE(S) MISC.( ) COMPRESSOR(S) FURNACE(S) ✓ES DUCT(S) GAS PIPE OUTLET(S) HEAT SOURCE: ❑ ELECTRIC ❑ GAS PLUMBING BATHTUB(S) LAVATORY(S) URINAL(S) WATER HEATER(S) DISHWASHER(S) RAIN WATER SYS. VACUUM BREAKER(S) ❑ ELECTRIC ❑ GAS DRINKING FOUNTAIN(S) SHOWER(S) WASH MACHINE OUTLET GAS PIPE OUTLET(S) SINK(S) WATER CLOSET(S) MISC.( INTERCEPTOR(S) SUMP(S) t'• .-DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I am authorized by the owner of the above premises to perform the work for which the permit application is made. I further agree to hold harmless the City of Federal Way as to any claim(induding costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,induding the undersigned,and filed against the City of Federal Way,but only where such claim arises out of the reliance of the city,including its officers and employees,upon the accuracy of the information supplied to the city as a part of this application. NAME/TITLE: -- DATE: ,11/7( . El PROPERTY OWNER ❑ APPLICANT ' CONTRACTOR FOR OFFICE USE.:ONLY:. Q:NEW 0 ADDITIONALTERATION CI REPAIR < ENANT IMPROVEMENT 'CENSUS CODE: °LOT SIZE: ZONING DESIGNATION BUILDING SHELL ONLY? ❑ YES ❑ NO COMP PLAN DESIGNATION BASIC PLAN? ❑ YES ❑ NO SECTION,; TOWNSHIP RANGE NEW ADDRESS,REQUIRED? ❑ YES ❑ NO PLATTED LOT? -' ❑ YES ❑ NO CHANGE OF USE? ❑ YES ❑ NO COMMUNITY DEVELOPMENT SERVICES•33530 FIRST WAY SOUTH•PO BOX 9718•FEDERAL WAY,WA 98063-9718•253-661-4000•FAX:253-661-4129 www.cityoffederalway.com Construction Permit Fee Calculation Sheet *******PLEASE NOTE: ALL FEES MUST BE VERIFIED BY CITY STAFF PRIOR TO ACCEPTANCE OF PAYMENT. CHECKS FOR INCORRECT AMOUNTS WILL NOT BE ACCEPTED!******* Building,mechanical,and fire prevention system fees are based on the following schedule. • TABLE A TOTAL VALUATION FEE FACTOR (1)$1.00 to$500.00 (1)$26.00 (2)$501.00 to$2,000.00 (2)$26.00 for the first$500.00 plus$3.50 for each additional$100.00 or fraction thereof,to and including $2,000.00 (3)$2,001.00 to$25,000.00 (3)$78.50 for the first$2,000.00 plus$15.50 for each additional$1,000.00 or fraction thereof,to and including$25,000.00 (4)$25,001.00 to$50,000.00 (4)$435.00 for the first$25,000.00 plus$11.00 for each additional$1,000.00 or fraction thereof,to and including$50,000.00. (5)$50,001.00 to$100,000.00 (5)$710.00 for the first$50,000.00 plus$8.00 for each additional$1,000.00 or fraction thereof,to and including$100,000.00. (6)$100,001.00 to$500,000.00 (6)$1,110.00 for the first$100,000.00 plus$6.00 for each additional$1,000.00 or fraction there2f,to and including$500,000.00 (7)$500,001.00 to$1,000,000.00 (7)$3,510.00 for the fist$500,000.00 plus$5.50 for each additional$1,000.00 or fraction thereof,to and including$1,000,000.00. (8)$1,000,001.00 and up (8)$6,260.00 for the first$1,000,000.00 plus$4.00 for each additional$1,000.00 or fraction thereof. Bold number is the base fee for the specified increment Ita/idzed underfined number Is the fee per additional specified increment PLUS: Add 65 percent of the base building permit fee for plan review fee. Add 25 percent of the base mechanical permit fee for mechanical plan review fee. Add 15 percent of the base building permit fee for Fire District#39 surcharge,commercial only. Add$4.50 for WA State Building Code Council,plus$2.00 per unit for duplex&above. **Electrical,plumbing,and mechanical fees are calculated separately** . M BUILDING • PROPOSED VALUATION: (Za 0 U D FEE FACTOR FROM TABLE A: Number: (a) Base Feed (b)Additional Increment Fee: l5 5 Estimated Permit Fee: (1) L„,-,7 �7 Estimated Plan Review Fee: (2)• 7 3 / , {? Estimated FW Fire Department Surcharge: (3) (COMMERCIAL ONLY) • MECHANICAL ' PROPOSED VALUATION: 4 �2 FEE FACTOR FROM TABLE A: Number: 3 (a)Base Fee: 7514.0 (b)Additional Ina ment Fee: �fi —27y Estimated Permit Fee: (4) �3 ) �} �Il Estimated Plan Review Fee: (5 P1 , ■ FIRE PREVENTION SYSTEM PROPOSED VALUATION: FEE FACTOR FROM TABLE A: Number: (a)Base Fee: (b)Additional Increment Fee: Estimated Permit Fee: (6) Estimated Plan Review Fee: (7) Base Fee Number of fixtures $22.50+{ .0. X$8.00/fixture}= 5-u (8)Estimated Permit Fee Estimated Permit Fee 5-4 SV X .65 = 35, 43 (9)Estimated Plan Review Fee Miscellaneous Fixture Charge: (10) Sub Total (Page one): Line(s)(1)+(2)+(3)+(4)+(5)+(6)+(7)+(8)+(9)+(10) = (11) 4 6-?, 23