Loading...
17-100294 IMP . . 7 Building - Single Family City of Federal way Permit #:17-100294-00-SF Community Development Dept. 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: NORPOINT HEIGHTS LOT 1 Project Address: 2613 SW 353RD PL Parcel Number:612500 0010 Project Description: NEW-Construction of a 2-story, 1836 square foot single family residence with a 57 square foot covered entry and a 626 square foot attached garage,including plumbing and mechanical. *** 4 bedrooms; $300,000 estimated selling price*** Owner Applicant Contractor Lender LANDMARK HOMES INC JULIE FISONLENNAR LENNAR NORTHWEST INC OWNER IS LENDER 2715 64TH AVE NE NORTHWEST INC 33455 6TH AVE S SUITE 1-B TACOMA WA 98422 33455 6TH AVE S UNIT 1-B FEDERAL WAY WA 98003 FEDERAL WAY,WA 98003 , Census Category: 101 -New Single Family House Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 1,836.00 Additional Permit Information New/Additional Sq.Feet-1st Floor 735 New/Additional Sq.Feet-2nd Floor 1101 New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 1836 New/Additional Sq.Feet-Basement 0 Basic Plan? No Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0 New/Additional Sq.Feet-Garage 626 Mechanical to be Included'? Yes Plumbing Work Valuations 20000 Mechanical Work Valuation? 10000 Number of Stories 2 New/Additional Sq.Feet-Other 57 Plumbing to be Included'? Yes New/Additional Sq.Feet-Total 2519 Will Certificate of Occupancy be Issued? Yes Occupancy#1-Use Residence(1 or 2 family) Comprehensive Plan Designation SF-High-Density Zoning Designation RS 7.2 Residential Total Valuation:235,872.43 Ducting 1 Fans 5 Fireplace Inserts 1 Furnaces 1 Gas Piping 1 Gas Pipe Outlets 5 Hot Water Tanks 1 E a d, ° e k Ti 1 Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1 Lavatories 5 Sinks 1 Water Closets 3 Hose Bibbs 2 CONDITIONS: 1. A total of 4 tree units shall be planted prior to final building inspection. For questions see approved tree calculation worksheet. r . - -+ e * A * - '* 4" PERMIT EXPIRES Monday,28 August,2017 Permit Issued on Wednesday,March 1,2017 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. G Owner or agent: l Date: 2'Z 0 l City of Federal Way Certificate of Occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance,this structure was in compliance with the various ordinances of the City regulating building construction or use.This certificate is valid ONLY when endorsed by City staff. Tenant Name: NORPOINT HEIGHTS LOT 1 Permit# 17-100294-00-SF Address: 2613 SW 353RD PL Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) 1,836.00 Owner Name: LANDMARK HOMES INC Owner Address: 2715 64TH AVE NE ' TACOMA WA 98422 a, 914017 Building Official Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible(within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. ', , , , IN a THIS CARD IS TO REMAIN ON-SITE Federal , Construction Inspection Record INSPECTION REQUESTS:(253)835-3050 PERMIT#: 17 100294 00 Address: 2613 SW 353RD PL Project: LANDMARK HOMES INC FEDERAL WAY WA 98023 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. ,❑ SWM Precon Site Mtg(4400) ® Initial Erosion Control(4365) ❑ Footings/Setback(4110) Approved To be done PRIOR to breaking ground Approved to place concrete By Date .�By Date ..By 4(J Date �fh1'/l-1 ® Foundation Wall(4115) ® Drainage/Downspout(4040) ® Plumbing Groundwork(4190) Approved to place concrete Approved to backfill Approved to cover 1Jo. *t..1;iirt. By A.y., Date 5/U),1 .,By l'9.AI Date 5//1/j 7 •..By Min110 ) Date 5 l I .: kik • ® Slab/Concrete Floor(4255) ® Underfloor Framing(4285) ® Floor Sheathing(4105) Approved to place concrete Approved to sheath floor Approved to install flooring . ..By Date ,.BY 14n) Date 5)igl)'1 By Date ( ) Roof Sheathing(4220) „'� El • 4245 Shear Walls 11 Rough Plumbing(4230) Approved to install bsiding Approved to install roofmg Approved tt PPr 13Y Date J(,--- , BY kJ Date 41111(7 ..By Vwb Date 'J113 1 1-7 El Mechanical Rough-in(4165) El Gas Piping(4125) ; El Fire/Draft Stops(4095) Approved Approved to release test Approved By ‘116 Date LI 41 t7 By V43 Date V(I 117 By /14\) Date G 12/4� 1 CI Interim Erosion Control(4370) Prior to scheduling a Framing inspection; 17 Framing(4120) Approved Electrical,Plumbing&Mechanical Rough-in Approved to insulate and Fire/Draft Stop inspections must be signed- By Date off and approved. IBC 109.3.4 By Date lel -7 '18 ��Insulation(4150) ,• Gypsum Wallboard Nailing(4130) „® Final Erosion Control(4375) Approved to install wallboard Approved to install mud&tape Approved ,By Date 4)Z-2 )11 „By 14441, Date 1 l'5lt1 ,.By Date El Final-Mechanical(4065) •El Final-Plumbing(4075) In Final-Building(4050) Approved Approved Approved . By ert3 Date CI 12° 11 `By A,N Date 9( q In By /i” Date ctl2ml 17 ❑ Rough Electrical ❑ Final Electrical ❑ Right of Way Approved Approved Approved By Date By Date By Date ipticeivED 1837 ,SAN 2 0 2' `' PERMIT APPLICATION CITY OF 11111. 1111.0.1 Federal Way ( orF - rivi n2 /347--PEPERMIT NUMBER 1 0 �� � - - TARGET DATE SITE ADDRESS SUITE/UNIT I 2613 SW 353rd Place Federal Way,WA PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL 4 $ 175,000.00 RS7.2 6 1 2 5 0 0 - 0 0 1 0 TYPE OF PERMIT pd BUILDING 0 PLUMBING ❑MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION NAME OF PROJECT Norpoint Heights Lot 01 Building a new SFR 1837 SF. PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE Lennar Northwest Inc. 253-590-2213 PROPERTY OWNER MAILINGADDRESS E-MAIL 33455 6th Ave S.,Unit 1-B julie.fison@lennar.com CITY STATE ZIP Federal Way WA 98003 NAME Lennar Northwest Inc. • PH253-590-2213 MAILING ADDRESS E-MAIL CONTRACTOR 33455 6th Ave S.,Unit 1-B julie.fison@lennar.com CITY STATE ZIP FAX Federal Way • sTWA 98003 FAx WA STATE CONTRACTOR'S LICENSE i EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE I CC LENNNANI893QG 11/ 7 /2017 NAME PRIMARY PHONE Julie Fison 253-590-2213 APPLICANT MAILINGADDRESS E ulie.f1SOn@lennar.com 33455S6th6th Ave S.,Unit 1-B J CIT STATE ZIP FAX Federal Way WA 98003 NAME PRIMARY PHONE PROJECT CONTACT Garrett Gibson 253-590-2209 • (The individual to receive and MAILING ADDRESS E-MAIL respond to all correspondence 33455 6th Ave S.,Unit 1-B garrett.gibson@lennar.com concerning this application) cntederal Way sTATE WA ZIP 8003 FAX NAME PROJECT FINANCING ® OWNER-FINANCED When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 79.27.095) I certify under penalty of perjury that I am the property owner or authorised agent of the property owner.I certify that to the best of my knowledge,the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I Portlier agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred In the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. SIGNATURE: Julie:Roan DATE 1/5/2017 PRINT NAME: Tulie Fison Bulletin#100—February 22,2016 Page 1 of 2 • k\Handouts\Permit Application - -110 • 3 VALUE OF MECHANICAL WORK MECHANICAL PERMIT • 10,000.00 Indicate how many of each type of fixture to be installed or relocated as art of this project.Do not include existing fixtures to remain. AIR HANDLING UNITS 5 FANS 4 GAS PIPE OUTLETS • OTHER(Describe) AIR CONDITIONER Z- FIREPLACE INSERTS HOODS(commercia)) BOILERS 1 FURNACES 1 HOT WATER IFANI4$(cas)Tankless COMPRESSORS GAS LOG SETS REFRIGERATION SYST 1 DUCTING 45 GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT • $ 20,000.00 Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. 2 BATHTUBS(orTrb/Shower Combo) 5 LAVS(Hand Sinks) 3 TOILETS WATER PIPING 1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS 1 SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS 1 SINKS(Kitchen/Ueaay) WATER HEATERS(mark)-2--- HOSE BIBBS SUMPS I WASHING MACHINES 16 TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS N/A Lakehaven Utilty District N/A EXISTING/PREVIOUS USE LOT SIZE(In Squire Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? Vacant 5648 ❑Yes In No ❑Yes at No • RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE BAS.EM•ENT. FIRST FLOOR(or Mobile Home) 0 735 1735 SECOND FLOOR 0 110.1; 10 - - COVERED ENTRY 0 57 57 DECK GARAGE Iff CARPORT 0 0 626 626 OTHER(descrtbel :...;:'..:1:1)::-.::,5. Area Totals EXISTING PROPOSED TOTAL 2519 2519 **NEWROMES ONLY.* ESTIMATED SELLING PRICE$ 300,000.00 #OF BEDROOMS 4 COMMERCIAL—NEW/ADDITION Area in Construction #of AREA DESCRIPTION q Occupancy Group(s) Stories Additional Information Square Feet NEW BUILDING ADDITION COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area m Occupancy Group(s) Construction #of Additional Information Square Feet eStorks IOTAI BUILDING : TENANT AREA ONLY PROJECT AREAONLY _ r �... . Bulletin#100—February 22,2016 Page 2 of 2 k:\Handouts\Pennit Application STREET LIGHT SS SW. 353RD PL E FS - S 'HT J-60C -LIGHT CABIN SD= �— �� S_�—SDCO TORTORM STUB SEWER STUB \ s EXISTING CONTOURS, PROPOSED CONTOURS TRACT B sr �S• TOP OF WALL ELEVATION (TYP.) ,,—EXPOSED WALL HEIGHT (TYP.) 1W=424.1 9.6 SW=41M1.5 BOTTOM OF WALL ELEVATION AT EXPOSED FACE (TYP.) BUILDING SETBACKS: PROM/GARAGE: 20' SIDE: V REAR: 5' INSTALL SILT �L FENCE AS SHOWN SS 1 20 -----a ------ rSD(".0 l 1 ........_matt, POWER CONCRETE,,_:.:.::..:. 7=418s 5 DRIVEWAY 5' o =nt3.o I PORCH g ' GARAGE R I I a VL9� m q ro 2 LOT 1 BUILDING FOOTPRINT \'` I1 30 BSBL (TYP.) WOOD FENCE ,CA VAULT O 75 LF OF KEYSTONE WALL 17' rn N NOTES: Ivr=o-t4.o 1.0 1 BW=473.0 1. FINISHED GRADE TO SLOPE AWAY NOT LESS THAN 1:12 FOR A MINIMUM of RETAINING WALL LEGEND 15 LF OF 6—FT OR TO PROPERTY LINE KEYSTONE ADJACENT TO FOUNDATION AND SHALL KEYSTONE RETAINING WALL PER DETAIL WALL START BELOW THE BOTTOMS OF ALL (O ON SHEET W1 PREPARED BY EARTH FOUNDATION VENTS. PROVIDE SOLUTIONS NW LLC. LOT ADDRESS: ADDITIONAL SOIL AS REQUIRED TO TBD CREATE DRAINAGE AWAY FROM STRUCTURES ALONG PROPERTY LINE IMPERVIOUS COVERAGE FEDERAL WAY, WA BETWEEN STRUCTURES. TOTAL IMPERVIOUS: 2,317 SF (41.0%) LOT SIZE = 51648 SF ROOF: 1,619 SF TCE=INSTALL TEMP. CONST. ENTRANCE 2. ANY PORTIONS OF STRUCTURES WITH DRIVEWAY: 553 SF LESS THAN 10-FEET OF SEPARATION WALKWAY: 37 SF HOUSE PLAN NO. 1837 A SHALL BE FIRE RATED. PATIO: 108 SF Job Number 0_ '° 2O 40 LENNAR NORTHWEST INC. 18210 Scale 1"=20 �G �s 18215 72ND AVENUE SOUTH NORPOINT HEIGHTS Dbrig9s Q' F KENT, WA 98032 Z (425)251-6222 RESIDENTIAL SITE PLAN Sneer prawn o o (425)251-8782 FAX SUBDIVISION -LOT NO 1 t/9/t7 i So<PING...okE�Py wEENVIRONMENTAL PARCEL NO TBD Of Date SURVEYINGCML SERVICES FIe:P:\180008\18218\lots\18218—Norpoint Heights—LoLdwg Plot Dote/Tlme:1/9/2017 5:31 PA DBRIGGS