17-100294 IMP . .
7
Building - Single Family
City of Federal way Permit #:17-100294-00-SF
Community Development Dept.
33325 8th Ave S
Federal Way,WA 98003 Inspection Request Line: (253)835-3050
Ph:(253)835-2607 Fax:(253)835-2609
Project Name: NORPOINT HEIGHTS LOT 1
Project Address: 2613 SW 353RD PL Parcel Number:612500 0010
Project Description: NEW-Construction of a 2-story, 1836 square foot single family residence with a 57 square foot
covered entry and a 626 square foot attached garage,including plumbing and mechanical. ***
4 bedrooms; $300,000 estimated selling price***
Owner Applicant Contractor Lender
LANDMARK HOMES INC JULIE FISONLENNAR LENNAR NORTHWEST INC OWNER IS LENDER
2715 64TH AVE NE NORTHWEST INC 33455 6TH AVE S SUITE 1-B
TACOMA WA 98422 33455 6TH AVE S UNIT 1-B FEDERAL WAY WA 98003
FEDERAL WAY,WA 98003
,
Census Category: 101 -New Single Family House
Includes: #1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V-B
Occupancy Load:
Floor Area(sq.ft.) 1,836.00
Additional Permit Information
New/Additional Sq.Feet-1st Floor 735 New/Additional Sq.Feet-2nd Floor 1101
New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 1836
New/Additional Sq.Feet-Basement 0 Basic Plan? No
Occupancy#1-Construction Type Type V-B New/Additional Sq.Feet-Deck 0
New/Additional Sq.Feet-Garage 626 Mechanical to be Included'? Yes
Plumbing Work Valuations 20000 Mechanical Work Valuation? 10000
Number of Stories 2 New/Additional Sq.Feet-Other 57
Plumbing to be Included'? Yes New/Additional Sq.Feet-Total 2519
Will Certificate of Occupancy be Issued? Yes Occupancy#1-Use Residence(1 or 2
family)
Comprehensive Plan Designation SF-High-Density Zoning Designation RS 7.2
Residential
Total Valuation:235,872.43
Ducting 1 Fans 5 Fireplace Inserts 1
Furnaces 1 Gas Piping 1 Gas Pipe Outlets 5
Hot Water Tanks 1
E
a d, ° e k Ti 1
Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1
Lavatories 5 Sinks 1 Water Closets 3
Hose Bibbs 2
CONDITIONS:
1. A total of 4 tree units shall be planted prior to final building inspection. For questions see approved
tree calculation worksheet.
r . - -+
e * A * - '*
4"
PERMIT EXPIRES Monday,28 August,2017
Permit Issued on Wednesday,March 1,2017
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Washington and the City of Federal Way. G
Owner or agent: l Date: 2'Z 0 l
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance,this structure was in
compliance with the various ordinances of the City regulating building construction or use.This certificate is valid
ONLY when endorsed by City staff.
Tenant Name: NORPOINT HEIGHTS LOT 1 Permit# 17-100294-00-SF
Address: 2613 SW 353RD PL
Includes: #1 #2 #3 #4
Occupancy Class: R-3
Construction Type: Type V-B
Occupancy Load:
Floor Area(sq.ft.) 1,836.00
Owner Name: LANDMARK HOMES INC
Owner Address: 2715 64TH AVE NE '
TACOMA WA 98422
a, 914017
Building Official Date
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible(within budgetary time and personnel limitations), the City neither guarantees
nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises. ',
, , , IN
a
THIS CARD IS TO REMAIN ON-SITE
Federal , Construction Inspection Record
INSPECTION REQUESTS:(253)835-3050
PERMIT#: 17 100294 00 Address: 2613 SW 353RD PL
Project: LANDMARK HOMES INC FEDERAL WAY WA 98023
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
,❑ SWM Precon Site Mtg(4400) ® Initial Erosion Control(4365) ❑ Footings/Setback(4110)
Approved To be done PRIOR to breaking ground Approved to place concrete
By Date .�By Date ..By 4(J Date �fh1'/l-1
® Foundation Wall(4115) ® Drainage/Downspout(4040) ® Plumbing Groundwork(4190)
Approved to place concrete Approved to backfill Approved to cover 1Jo. *t..1;iirt.
By A.y., Date 5/U),1
.,By l'9.AI Date 5//1/j 7 •..By Min110
) Date 5 l I
.: kik •
® Slab/Concrete Floor(4255) ® Underfloor Framing(4285) ® Floor Sheathing(4105)
Approved to place concrete Approved to sheath floor
Approved to install flooring
.
..By Date ,.BY 14n) Date 5)igl)'1 By Date
( ) Roof Sheathing(4220) „'�
El •
4245 Shear Walls 11 Rough Plumbing(4230)
Approved to install bsiding Approved to install roofmg Approved
tt PPr
13Y Date J(,--- , BY kJ Date 41111(7 ..By Vwb Date 'J113 1 1-7
El Mechanical Rough-in(4165) El Gas Piping(4125) ; El Fire/Draft Stops(4095)
Approved Approved to release test Approved
By ‘116 Date LI 41 t7 By V43 Date V(I 117 By /14\) Date G 12/4� 1
CI Interim Erosion Control(4370) Prior to scheduling a Framing inspection; 17 Framing(4120)
Approved Electrical,Plumbing&Mechanical Rough-in Approved to insulate
and Fire/Draft Stop inspections must be signed-
By Date off and approved. IBC 109.3.4
By Date lel -7
'18 ��Insulation(4150) ,• Gypsum Wallboard Nailing(4130) „® Final Erosion Control(4375)
Approved to install wallboard Approved to install mud&tape Approved
,By Date 4)Z-2 )11 „By 14441, Date 1 l'5lt1 ,.By Date
El Final-Mechanical(4065) •El Final-Plumbing(4075) In Final-Building(4050)
Approved Approved Approved .
By ert3 Date CI 12° 11 `By A,N Date 9( q In By /i” Date ctl2ml 17
❑ Rough Electrical ❑ Final Electrical ❑ Right of Way
Approved Approved Approved
By Date By Date By Date
ipticeivED 1837
,SAN 2 0 2' `' PERMIT APPLICATION
CITY OF 11111. 1111.0.1
Federal Way ( orF - rivi
n2 /347--PEPERMIT NUMBER 1 0 �� �
- -
TARGET DATE
SITE ADDRESS SUITE/UNIT I
2613 SW 353rd Place Federal Way,WA
PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL 4
$ 175,000.00
RS7.2 6 1 2 5 0 0 - 0 0 1 0
TYPE OF PERMIT pd BUILDING 0 PLUMBING ❑MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION
NAME OF PROJECT Norpoint Heights Lot 01
Building a new SFR 1837 SF.
PROJECT DESCRIPTION
Detailed description of work to
be included on this permit only
NAME PRIMARY PHONE
Lennar Northwest Inc. 253-590-2213
PROPERTY OWNER MAILINGADDRESS E-MAIL
33455 6th Ave S.,Unit 1-B julie.fison@lennar.com
CITY STATE ZIP
Federal Way WA 98003
NAME
Lennar Northwest Inc. • PH253-590-2213
MAILING ADDRESS E-MAIL
CONTRACTOR 33455 6th Ave S.,Unit 1-B julie.fison@lennar.com
CITY STATE ZIP FAX
Federal Way •
sTWA 98003 FAx
WA STATE CONTRACTOR'S LICENSE i EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE I
CC LENNNANI893QG 11/ 7 /2017
NAME PRIMARY PHONE
Julie Fison 253-590-2213
APPLICANT MAILINGADDRESS E ulie.f1SOn@lennar.com
33455S6th6th Ave S.,Unit 1-B J
CIT STATE ZIP FAX
Federal Way WA 98003
NAME PRIMARY PHONE
PROJECT CONTACT Garrett Gibson 253-590-2209 •
(The individual to receive and MAILING ADDRESS E-MAIL
respond to all correspondence 33455 6th Ave S.,Unit 1-B garrett.gibson@lennar.com
concerning this application) cntederal Way sTATE WA ZIP
8003 FAX
NAME
PROJECT FINANCING ® OWNER-FINANCED
When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE
(RCW 79.27.095)
I certify under penalty of perjury that I am the property owner or authorised agent of the property owner.I certify that to the best
of my knowledge,the information submitted in support of this permit application is true and correct.I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit.I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I
Portlier agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred In
the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the city as a part of this application.
SIGNATURE: Julie:Roan DATE 1/5/2017
PRINT NAME: Tulie Fison
Bulletin#100—February 22,2016 Page 1 of 2 • k\Handouts\Permit Application
- -110
• 3
VALUE OF MECHANICAL WORK
MECHANICAL PERMIT
• 10,000.00
Indicate how many of each type of fixture to be installed or relocated as art of this project.Do not include existing fixtures to remain.
AIR HANDLING UNITS 5 FANS 4 GAS PIPE OUTLETS • OTHER(Describe)
AIR CONDITIONER Z- FIREPLACE INSERTS HOODS(commercia))
BOILERS 1 FURNACES 1 HOT WATER IFANI4$(cas)Tankless
COMPRESSORS GAS LOG SETS REFRIGERATION SYST
1 DUCTING 45 GAS PIPING WOODSTOVES
VALUE OF PLUMBING WORK
PLUMBING PERMIT • $ 20,000.00
Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain.
2 BATHTUBS(orTrb/Shower Combo) 5 LAVS(Hand Sinks) 3 TOILETS WATER PIPING
1 DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe)
DRAINS 1 SHOWERS VACUUM BREAKERS
DRINKING FOUNTAINS 1 SINKS(Kitchen/Ueaay) WATER HEATERS(mark)-2---
HOSE BIBBS SUMPS I WASHING MACHINES 16 TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS
N/A Lakehaven Utilty District N/A
EXISTING/PREVIOUS USE LOT SIZE(In Squire Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM?
Vacant 5648 ❑Yes In No ❑Yes at No
•
RESIDENTIAL - NEW OR ADDITION
AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
BAS.EM•ENT.
FIRST FLOOR(or Mobile Home) 0 735 1735
SECOND FLOOR 0 110.1; 10 - -
COVERED ENTRY 0 57 57
DECK
GARAGE Iff CARPORT 0 0 626 626
OTHER(descrtbel :...;:'..:1:1)::-.::,5.
Area Totals EXISTING PROPOSED TOTAL
2519 2519
**NEWROMES ONLY.*
ESTIMATED SELLING PRICE$ 300,000.00 #OF BEDROOMS 4
COMMERCIAL—NEW/ADDITION
Area in Construction #of
AREA DESCRIPTION q Occupancy Group(s) Stories Additional Information
Square Feet
NEW BUILDING
ADDITION
COMMERCIAL—REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION Area m Occupancy Group(s) Construction #of Additional Information
Square Feet eStorks
IOTAI BUILDING :
TENANT AREA ONLY
PROJECT AREAONLY _ r
�... .
Bulletin#100—February 22,2016 Page 2 of 2 k:\Handouts\Pennit Application
STREET LIGHT
SS
SW. 353RD PL
E
FS - S
'HT J-60C
-LIGHT CABIN
SD= �—
��
S_�—SDCO
TORTORM STUB
SEWER STUB \
s
EXISTING
CONTOURS,
PROPOSED
CONTOURS
TRACT B
sr
�S•
TOP OF WALL
ELEVATION (TYP.)
,,—EXPOSED WALL HEIGHT (TYP.)
1W=424.1 9.6
SW=41M1.5
BOTTOM OF WALL ELEVATION
AT EXPOSED FACE (TYP.)
BUILDING SETBACKS:
PROM/GARAGE: 20' SIDE: V REAR: 5'
INSTALL SILT �L
FENCE AS SHOWN
SS 1 20
-----a ------ rSD(".0 l
1
........_matt,
POWER
CONCRETE,,_:.:.::..:.
7=418s 5
DRIVEWAY
5'
o =nt3.o
I
PORCH g '
GARAGE R
I
I
a VL9�
m
q
ro
2
LOT 1
BUILDING
FOOTPRINT
\'` I1 30
BSBL (TYP.)
WOOD FENCE
,CA
VAULT
O
75 LF OF
KEYSTONE
WALL
17'
rn
N
NOTES:
Ivr=o-t4.o 1.0 1
BW=473.0
1. FINISHED GRADE TO SLOPE AWAY NOT
LESS THAN 1:12 FOR A MINIMUM of
RETAINING WALL LEGEND 15 LF OF
6—FT OR TO PROPERTY LINE
KEYSTONE
ADJACENT TO FOUNDATION AND SHALL
KEYSTONE RETAINING WALL PER DETAIL WALL
START BELOW THE BOTTOMS OF ALL
(O ON SHEET W1 PREPARED BY EARTH
FOUNDATION VENTS. PROVIDE
SOLUTIONS NW LLC.
LOT ADDRESS:
ADDITIONAL SOIL AS REQUIRED TO
TBD
CREATE DRAINAGE AWAY FROM
STRUCTURES ALONG PROPERTY LINE
IMPERVIOUS COVERAGE
FEDERAL WAY, WA
BETWEEN STRUCTURES.
TOTAL IMPERVIOUS: 2,317
SF (41.0%) LOT SIZE = 51648 SF
ROOF: 1,619 SF
TCE=INSTALL TEMP. CONST. ENTRANCE
2. ANY PORTIONS OF STRUCTURES WITH
DRIVEWAY: 553 SF
LESS THAN 10-FEET OF SEPARATION
WALKWAY: 37 SF
HOUSE PLAN NO. 1837 A
SHALL BE FIRE RATED.
PATIO: 108 SF
Job Number
0_
'° 2O 40
LENNAR NORTHWEST INC.
18210
Scale 1"=20
�G �s 18215 72ND AVENUE SOUTH
NORPOINT HEIGHTS
Dbrig9s
Q'
F KENT, WA 98032
Z (425)251-6222
RESIDENTIAL SITE PLAN
Sneer
prawn
o
o (425)251-8782 FAX
SUBDIVISION -LOT NO 1
t/9/t7
i
So<PING...okE�Py
wEENVIRONMENTAL
PARCEL NO TBD
Of
Date
SURVEYINGCML
SERVICES
FIe:P:\180008\18218\lots\18218—Norpoint Heights—LoLdwg
Plot Dote/Tlme:1/9/2017 5:31 PA DBRIGGS