Loading...
17-102024 '. Building - Single Family City of Federal Way Permit #:17-102024-00-SF Community Development Dept. 33325 8th Ave S Federal Way,WA 98003 Inspection Request Line: (253)835-3050 Ph:(253)835-2607 Fax:(253)835-2609 Project Name: GUECO Project Address: 29410 7TH AVE SW Parcel Number: 119600 2950 Project Description: REP-Underpinning of existing residential building to stabilize the foundation.No Plumbing or Mechanical. Owner Applicant Contractor Lender ROLANDO GUECO TARA TODDMATVEY TARA TODDMATVEY OWNER IS LENDER 29410 7TH AVE SW FOUNDATION REPAIR FOUNDATION REPAIR FEDERAL WAY WA 98023-3524 1912 S 146TH ST 1912 S 146TH ST SEATAC WA 98168 SEATAC WA 98168 , Census Category:434-Residential alt/add- no change in number of units Includes: ( #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V-B Occupancy Load: Floor Area(sq.ft.) Additional Permit Information Occupancy#1-Construction Type Type V-B Mechanical to be Included'? No Number of Stories 1 Is this an Online or O.T.C.application? No Plumbing to be Included No Occupancy#1-Use Residence(1 or 2 family) Comprehensive Plan Designation SF-High-Density Zoning Designation RS 9.6 Residential Total Valuation: 13,890.00 CONDITIONS: Special inspections required; provide inspector's report on-site at final inspection PERMIT EXPIRES Saturday, 18 November,2017 Permit Issued on Monday,May 22,2017 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. 9 Owner or agent: Y7/ Date: SI'Z2-/ tll-cc\ ♦ Y • THIS CARD IS TO REMAIN ON-SITE nr� Construction Inspection Record Feiz�erai Way INSPECTION REQUESTS:(253)835-3050 PERMIT#: 17 102024 00 Address: 29410 7TH AVE SW Project: MARIA L GUECO FEDERAL WAY WA 98023-3524 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. ® Final-Building(4050) Approved By 4 y.) Date n1) Jill/ Rough Electrical ❑ Final Electrical Right of Way Approved Approved Approved By Date By Date By Date SFA Design Group, LLC STRUCTURAL 1 CIVIL 1 LAND USE PLANNING 1 SURVEYING 9020 SW Washington Square Dr., Suite 505 sfa Portland,Oregon 97223 P:(503)641-8311 F: (503)643-7905 www.sfadg.com Special Inspection FINAL SUMMARY REPORT September 8,2017 City of Federal Way Attn: Building Permits and Inspections RE: Project Name: Gueco Residence Underpinning Project No.: MFR17-011 Permit No.: 17-102024-00-SF Address: 29410 7Th Ave. SW,Federal Way, 98023 Dear Building Inspection Division: This letter serves to certify that in accordance with Chapter 18 of the International Building Code requirements outlined in the General Structural Notes on S1.1 of the approved permit drawings, SFA Design Group,LLC has performed special inspection as detailed below. The inspector observed the installation of FSI PP288 push piers,verifying pier locations, installation depth, installation pressure,bracket type,pier type,pier diameter and thickness. To confirm pier capacity, load tests were observed following installation and the results were within approved allowances. Please see attached field installation logs and load test data dated, 9/7/17—9/8/17. All anchors were installed per the intent of the design and any installation deviations were reviewed and approved by this office with no outstanding non-compliance items. Our inspection and testing services do not constitute a warranty or guarantee of any type and were provided and intended to help reduce the risk of construction defects,deficiencies or omissions that may arise during and after construction.It is the contractor's responsibility to perform their work in accordance with the approved construction documents.All inspections and tests were performed and reported according to the requirements of the City Building Regulations and these Administrative Rules and,to the best of my knowledge,the work was in conformance with the applicable workmanship provisions of the State Building Code and Standards. Sincerely, Keith Caylor i��` t.re Air Operations Manager ♦ `r.. Cc: Tara Todd,Matvey Foundation Repair Reviewed by: Jeff Fitch,PE,P.Eng, SFA Design Group,LLC .4 '"' \ , - _ ' SFA ©nigra Grnaap, um r STRUCTURAL I CML I LAND USE_PLANNING I SURVEYING 9020 SW Washington Square Or., Suite 581813 Rutan Or,Suite C ftlfa Portland,Oregon 97223 4 ivermwe,CA 94551 P:(583)641-8311 F: (503(643-7905 www.sfadg.oarn /' FIELD INSTALLATION LOG Prosect Name ``-'e l er., Contractor. jeizekf.., > � " _ ._..-.p^ _ _...7�L��r., c Project' Foreman: She Address: � b_ Co it __ ___ _ Install Date: J ! 2 Contractor Arrival: Inspector Arrival: nspector rture:/'P Permit N I _ i I mut umber _- Inspector Name: l 1N Y;2Z., i Jurisdiction: i t �'� � 3 Pier Wall Pier Segment /Installation Location 1 Pan Description I Pier OD,in i Thickness,in Length,ft j Pressure,psi ! a S r I ‘' _ A r ----- ; /�s0 d 3 ..--, ti MN . f C1 - /u4+>i�C y1✓ f 'if 6 —pts.5 r 4 cs / , ' d / ; : r - f L t j jj I t f 1 . Non-Compliance Items: l ', a inspector .1' +•— �^+._, Rev 2018.01 - - uuhattlimirdwDt� int.Su6140 PaTtland.creson Ma Ir 811-1131t t 1514 643- 905 exasia LOADTESTL i PolectNanw r G<C r StleAckkesm { t 5Lormaaw I t I � -I �.. r «rest T Pget - I reits-__ _.__a___-- 5 xrmr 0 /5 nem A#> aw 3ff mns r 60 air is rT Re yt- 1 17 < SlralEr 1. 2 saw--___ 7S rair 10 nttr lig i z � _ n S. rtbele_ p eb3ed s - Pasaaat urze " 50 tratealifientim-'srued-Load iniataaltier r gewgaw 0-080 Inches bebtieart6 end 60=Was,The feed b3stsball be - e I I f.g RECD:"/ ' PERMIT APPLICATION CITY OF „d Federal /t! PERI=CENTER+33325 8th Avenue South+Federal Way,WA 98003-6325 Y Y x MAY p 3 2017 253-835-2607+FAX 253-835-2609+permitcenter(n;cityoffederalway.com CITY OF FQDE/ W / PERMIT NUMBER! "7 _ I <0 _S F �(/1 i -1t� TARGET DATE I ,i SITE ADDRESS SUITE/UNIT• 29410 7th Ave SW, Federal Way Wa 98023 PROJECT VALUATION ZONING ASSESSOR'S TAI[/PANEL• $ 13,890.00 SF/Res Use 1 1 9 6 0 0 - 2 9 5 0 TYPE OF PERMIT BUILDING 0 PLUMBING 0 MECHANICAL 0 DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION NAME OF PROJECT Gueco Residence Underpinning of existing residential building to stabilize the foundation. PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE Rolando&Maria Gueco 206-683-4145 PROPERTY OWNER MAG ADDRESS E-MAIL 29410 7th Ave SW rdgueco@yahoo.com CITY STATE ZIP Federal Way Wa 98023 NAME PHONE Matvey Foundation Repair 253-327-1650 MAILING ADDRESS E-MAIL CONTRACTOR 1912 S 146th St matveyconstruction@hotmail.com CITY STATE ZIP FAX Seatac Wa 98168 n/a WA STATE CONTRACTOR'S LICENSE• EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE• MATVECI991CB 9/ 2 7/1 7 NAME PRIMARY PHONE Tara Todd 253-680-9200 APPLICANT MAILING ADDRESS E-MAIL 1912 S 146th St permits@matveyfoundationrepair.com CITY STATE ZIP FAX Seatac Wa 98168 n/a NAME PRIMARY PHONE PROJECT CONTACT Tara Todd 253-680-9200 (The individual to receive and MAILING ADDRESS E-MAIL respond to aA correspondence 1912 S 146th St pemrits@matveyfoundationrepair.com concerning this application) CITY STATE ZIP FAX Seatac Wa 98168 n/a NAME PROJECT FINANCING lit OWNER-FINANCED When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27.095) I certify/under penalty of perjury that I am the property owner or authorised agent of the property owner.I certify that to the best of my knowledge,the information submitted in support of this permit application is true and correct.I certl/j that I will comply with all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit.I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as a part of this application. SIGNATURE: /0-4." 411. DATE 4/27/17 PRINT Nom: Tara Todd Bulletin#100—January 29,2016 Page 1 of 2 k:\Handouts\Permit Application VALUE OF MECHANICAL WORK MECHANICAL PERMIT $ n/a Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER(Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS(Commercial( BOILERS FURNACES HOT WATER TANKS(Goa( COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES VALUE OF PLUMBING WORK PLUMBING PERMIT $ n/a Indicate how many of each type of fixture to be installed or relocated as part of this project.Do not include existing fixtures to remain. BATHTUBS(or Tub/Shower Combo( LAVS(Hud Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS(Ritchen/uNity) WATER HEATERS(F ochic( HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS No Lakehaven Water&Sewer Lakehaven Water&Sewer $ EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED.FIRE SUPPRESSION SYSTEM? Single Family/Res Use 0 YesX No ❑Yes XNo 11,786 RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE NASA ENT I FIRST FLOOR(or Mobile Home) 1320 1 #Fi t 1;;.04..^ COVERED ENTRY � k GARAGE X CARPORT ❑ 510 F a°ir Area Totals LPRO TOTAL 3440 n/a 3440 ESTIMATED SELLING PRICE$ n/a #OF BEDROOMS COMMERCIAL—NEW/ADDITION Area in PIConstruction •of AREA DESCRIPTION Square Feet Occupancy Oron s) ypeStories Additional Information NEW ADDITION COMMERCIAL—REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area Occupancy Groups) Construction #of Additional Information SN�uare Feet T"e Stories a;;' t8 ,� (a i i ? �� �7EtES o a 1 ', �(z, � ra 1( S + '•" ii3l E c a i pa i. ..�1 � i,, k - 777777 its t i7�i ( i�. lE a a TENANT AREA ONLY P neCT AREA GEE.? Bulletin#100—January 29,2016 Page 2 of 2 k:\Handouts\Permit Application