10-101062 ` R "
• • Building - Multi Family '
City of Federal Way
Community Development Services Permit #: 10-101062-00-M F
P.O.Box 9718
Federal Way,WA 98063-9718 I
Ph:(253)835-2607 Fax (253)835-2609 , i `� Inspection Request Line: (253)835-3050
Vi l.:' se`s
Project Name: SOUTHRIDGE HOUSE APARTMENTS-UNIT 106
Project Address: 30838 14TH AVE S Apt 106 Parcel Number: 082104 9231
Project Description: REM-Remodel interior of Unit 106,including relocation of walls and plumbing to
reconfigure existing space. Includes plumbing& mechanical.
Owner Applicant Contractor Lender
KING COUNTY HOUSING DAVID CURRAN KING COUNTY HOUSING KING COUNTY HOUSING
AUTHORITY S H K S ARCHITECTS AUTHORITY AUTHORITY
625 ANDOVER PARK W 1050 38TH ST HOUSIT*215KD(3/12/11) 625 ANDOVER PARK W
TUKWILA WA 98188 SEATTLE WA 98103 600 ANDOVER PARK W TUKWILA WA 98188
SEATTLE WA 98188
Census Category: 434 -Residential alt/add- no change in number of units
Includes: #1 #2 #3 #4
Occupancy Class: R-2 '
Construction Type: Type I-B
Occupancy Load:
Floor Area(sq.ft.) 0 0 0 0
Existing Sprinkler System in Building? Yes Mechanical to be Included? Yes
Number of Stories 1 Permit for Building Shell Only? No
Plumbing to be Included? Yes New/Additional Sq.Feet-Total 0
Occupancy#I -Use Apartment House Zoning Designation RM 2400
- f ¢ . ,o: ': d , ;,,,°p,',..•
• ;-t�st�.: , q€
Fans 2
'.x .. o -
„a � ,....„.a. ;: �s ,A, .,,r�.,�--_ham °?•:�" ,,..,: ,, ....t ,,.v ,. /�= .a e __ • •. _,
Lavatories 1 Showers 1 Sinks 1
Water Closets 1
PERMIT EXPIRES Sunday, November 21, 2010
Permit Issued on Tuesday, May 25, 2010
I hereby certify that the above information is correct and that the construction on the above described property and
the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington
and the City of Federal Way.
Owner or agent: fy 4
/y - Date: 5/2 5//C)
F 1 NO./10(M 2/ t/j1
a
DATE INSPECTOR AREA AND TYPE OI+ INSPECTION
1/72 //i) rGr riLt - /941/4 in2/13:4/A/6 t46N61 Swot, 57711-`1-Ol�
• '' THIS CARD IS TO RE AIN ON-SITE
CITY OF • Construction Ins tion Record
Federal Way INSPECTION REQU TS: (253)835-3050
PERMIT#: 10-101062-00-MF Address: 30838 14TH AVE S Apt 106
Owner: KING COUNTY HOUSING AUTHOR FEDERAL WAY, WA 98003
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as
possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your
inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
El SWM Precon Site Mtg(4400) ❑ Initial Erosion Control(4365) Footings/Setback(4110)
Approved To be done prior to breaking ground Approved to place concrete
By Date By Date By Date
•
O Foundation Wall(4115) ❑ Drainage/Downspout(4040) Re-steel(4215)
Approved to place concrete Approved to backfill .%'f/ApprovedjJedto
place concrete or grout
By Date By Date By L, Date /J/z/, 9
El Plumbing Groundwork(4190) ❑ Slab/Concrete Floor(4255) ❑ Underfloor Framing(4285)
Approved to cover Approved to place concrete Approved to sheath floor
By Ltd,, Date t O`22- By Date By Date
Floor Sheathing(4105) El Shear Walls (4245) 0 Roof Sheathing(4220)
Approved to install flooring Approved to install siding .Approved to install roofing
By Date By Date By Date
El Rough Plumbing(4230) * `0 Mechanical Rough-in(4165) Gas Piping(4125)
Approved 13 1 Approved Approved to release test
By �L/ Date j/ By ,/—(.7fDate /I/22/2049 By Date
❑ Fire/Draft Stops(4095) ❑ Interim Erosion Control(4370) Prior to scheduling a Framing inspection;
Approved Approved Electrical,Plumbing&Mechanical Rough-in and
By Date By Date Fire/Draft Stopproved IBC 109 3e�igned-off and
Z23t= t
O Framing(4120) 0 Insulation (4150) 0 Gypsum Wallboard Nailing(4130)
Approved to insulate Approved to install wallboard Approved to install mud&tape
By 0 Date t 2-3\_-16 By Date By Date 1/7/i,
O Suspended Ceiling Grid (4265) ❑ Final-Fire Department(4060) El
Final-Planning(4070)
Approved to drop tile Approved Approved
By Date By C../ Date Z/` /U' By Date
O Final-Public Works(4080) ❑ Final Erosion Control(4375) E Final-Mechanical(4065)
Approved Approved Approved
By Date By Date By (1-11N‘.,-
Q— l 2-3- % I
O Final-Plumbing(4075) El
Final-Building(4050)
Approved Approved
By Li „..., Date ft_b,1 1 By Date 0'2/0
❑ Rough Electrical
El
Final Electrical Right of Way
Approved Approved Approved
By Date By Date By Date
—.��..� ECEIV Q k =
Federal Wa PERMIT SF F CO ME EL PL DE EN FP
y
• COMMUNITY 5383 09 FAXMEI253TStRV26, R 16 2 PPLICATION - �
ww u.c9trotfederduay.c(u
OF FEDERAL WAY
SITE ADDRESS
30838 14th Ave S, Federal Way WA 98003 -- Sofer'r2,Zere FATS,
.fit/UNIT* ZONING ZONING ASSESSOR'S TAX/PARCEL S
3�l 5S RM 1800 0 8 2 1 0 4 _ 9 2 3 1
NAME or PROJECT
(Tenant or Homeowner Name) O ut Tif-46Q E ;Se, TS
)(BUILDING )(PLUMBING MECHANICAL
TYPE OF PERMIT 0 DEMOLITION 0 ELECTRICAL 0 ENGINEERING 0 FIRE PREVENTION
MISCELLANEOUS TENANT IMPROVEMENTS WITHIN UNIT, . NO WORK TO
PROJECT DESCRIPTION OCCUR OUTSIDE OF EXISTING BUILDING ENVELOPE.
Detailed description of work to
be included on this permit only
NAME PRIMARY PHONE
PROPERTY OWNER King County Housing Authority-C:Alton Leung ( 206 ) 574 -1213
MAILING ADDRESS.CITY.STATE.ZIP E-MAIL
625 Andover Park W. Suite 107;Tukwila, WA 98188 AltonL@kcha.org
OWNER IS ALSO: El CONTRACTOR ® APPLICANT El PROJECT CONTACT
NAME PRIMARY PHONE
CONTRACTOR MAILING ADDRESS.CITY.STATE,ZIP FAX
WA STA 0 ..• • M EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE A
NAME PRIMARY PHONE
APPL
ICANT King County Housing Authority-C:Alton Leung (206 ) 574 -1213
MAILING ADDRESS,CITY.STATE,ZIP FAX
625 Andover Park W. Suite 107;Tukwila, WA 98188 ( ) -
PROJECT CONTACT NAME PRIMARY PHONE
(The individual to receive and King County Housing Authority-C: Alton Leung ( 206 ) 574 -1213
respond to all correspondence MAILING ADDRESS.CITY.STATE,ZIP FAX
concerning this application) 625 Andover Park W. Suite 107;Tukwila, WA 98188 ( ) -
ALTERNATE CONTACT NAME: PRIMARY PHONE E-MAIL
David Curran ( 206) 675 - 9151 davidc@shksarchitects.com
PROJECT FINANCING NAME
E OWNER-FINANCED
Required for projects with
value of$5.000 or more MAILING ADDRESS.CITY.STATE.ZIP PRIMARY PHONE
(RCW 19.27.095) ( )
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best
of my knowledge,the information submitted in support of this permit application is true and correct.I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses,and attorneys'fees incurred
in the investigation and defense of such claim),which may be made by any person, including the undersigned, and filed against the
city, but only where such claim arises out of the reliance of the city, including its officers and employees,upon the accuracy of the
information supplied to the city as a part oft ' application. may.
SIGNATURE: 44.5 �/ DATE /�/� v
PRINT NAME: .eiLT2/v e-ear.(/Ej
Bulletin#100-January I.2010 Page 1 of 4 k:\Handouts\Permit Application
x • •
ME HANICkL + ; 'I s
Value of Mechanical Work$ 7®d (A COPY OF BID OR ESTIMATE MUST BE PROVIDED)
Indicate number of each type of facture to be installed or relocated as part of this project. Do not include existing fixtures to remain.
AIR HANDLING UNITS / FANS(8$7/4 .,) GAS PIPE OUTLETS / OTHER��� (Describe)
AIR CONDITIONER FIREPLACE INSERTS HOODS(Commercial) etre-elf/et L>
BOILERS FURNACES HOT WATER TANKS(Gas)
COMPRESSORS GAS LOG SETS REFRIGERATION SYST
DUCTING GAS PIPING WOODSTOVES
P P
Y n i Y" 41, # t
f'',..,77:4,,,,4::,', 1,4f °}
Indicate number of each type of fixture to be installed or relocated as part of this project. Do not include existing fixtures to remain.
BATHTUBS(orTob/Shower Combo) / LAVS(Hand Sinkol _,ii_ TOILETS WATER PIPING
DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe)
r
DRAINS / SHOWERS VACUUM BREAKERS
DRINKING FOUNTAINS X SINKS(Kitchen/utility) WATER HEATERS(Electric)
HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES
GENERAL INFORMATION
PROJECT VALUATION WATER
WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS
$ ✓)�V
$
EXISTING/PREVIOUS USE LOT SIZE(In Square Feet) EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM?
R-2 Multifamily 44,989 SF XYes ❑ No ❑Yes X No
,, r,, r. ',- - :-.,ra. ,,.. �. kms (, . a'
AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
BASEMENT
FIRST FLOOR(or Mobile Home)
SECOND,RLOOR;
COVERED ENTRY
DECD-
GARAGE 0 CARPORT 0
OTHER(describe)
F.S[SI'Ia(i PROPOSE!) TOTAL
Area Totals
**NEW HOMES ONLY**
ESTIMATED SELLING PRICE$ #OF BEDROOMS
."*.`":1m.,/-_ ,','- ' 1,,,,t
AREA DESCRIPTION Area Occupancy Group(s) Construction #of Additional Information l
in Square Feet Type Stories
NEW BUILDI G
ADDITION
�E � u. � /�E' E �; 6 ® ` kib Y ;, o':—,, , , : V '
AREA DESCRIPTION Area Occupancy Group(s) Constructionµ #of
in Square Feet P y P( ) Type Stories Additional Information
TOTAL iBUILDING 56,72
TENANT AREA ONLY 56,720 SF R-2 6
PROJECTARs oxLY 2390 SF R-2: 1
Bulletin#100—January 1,2010 Page 2 of 4 k:\Handouts\Permit Application