17-101879 b
� 4
•
- -= t. ' Building - Commercial
City urFederal Way � � i ' Permit #:17-101879-00-CO
Community Development Dept. )
33325 8th Ave S
Federal Way,WA 98003 Inspection Request Line: (253)835-3050
Ph:(253)835-2607 Fax:(253)835-2609
Project Name: FEDERAL WAY CENTER
Project Address: 2505 S 320TH ST Parcel Number:797820 0535
Project Description: ADD/ALT-Interior lighting,ceiling and finish upgrades; replacement of stair&balcony
guardrails; add(2)occupant canopies and site stairs;new exterior door. No plumbing or
mechanical.
Owner Applicant Contractor Lender
D M VENTURES FW CENTER LLC PRESTON WELCHJPC NORTHWAY CONSTRUCTION OWNER IS LENDER
6725 116TH AVE NE SUITE 100 ARCHITECTS INC
KIRKLAND WA 98033 909 112TH AVE NE 433 VALENTINE AVE SE SUITE 10.
BELLEVUE WA 98004 PACIFIC WA 98047
Census Category: 437-Commercial alt/add/conversion
Includes: #1 #2 #3 #4
Occupancy Class: B
Construction Type: Type I-A
Occupancy Load:
Floor Area(sq.ft.) 937.00 0.00 0.00 0.00
Additional Permit Information
New/Additional Sq.Feet-1st Floor 0 New/Additional Sq.Feet-2nd Floor 0
New/Additional Sq.Feet-3rd Floor 0 Occupancy#1-Area(Sq.Feet) 937
New/Additional Sq.Feet-Basement 0 Occupancy#1-Construction Type Type I-A
New/Additional Sq.Feet-Deck 0 New/Additional Sq.Feet-Garage 0
Mechanical to be Included? No Plumbing Work Valuation9 0
Mechanical Work Valuation9 0 Number of Stories 6
New/Additional Sq.Feet-Other 0 Is this an Online or O.T.C.application No
Permit for Building Shell Only, No Plumbing to be Included? No
New/Additional Sq.Feet-Total 0 Will Certificate of Occupancy be Issued9 No
Occupancy#1-Use Professional Comprehensive Plan Designation City Center Core
Services/Offices
Zoning Designation CC-C
Total Valuation:150,000.00
PERMIT EXPIRES Saturday, 13 January,2018
Permit Issued on Monday,July 17,2017
I hereby certify that the above infor ion is orrect and that the construction on the above described property
and the occupy the us I be' - cordance with the laws, rules and regulations of the State of
as ngt,n and the City of Federal Way. 7
. (2
Owner or agent:
H. Date: 7 1 1
•
• .gig,
Baia
City of Federal Way
Certificate of Occupancy
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Secti e
R110 of the International Residential Code is certifying that at the time of issuance,this structure was in
compliance with the various ordinances of the City regulating building construction or use.This certifica is valid
ONLY when endorsed by City staff.
Tenant Name: FEDERAL WAY CENTER Permi • 17-101879-00-CO
Address: 2505 S 320TH ST
Includes: #1 #2 #4
Occupancy Class: B
Construction Type: Type I-A
Occupancy Load: 0.00 0.00 0.00 0.00
Floor Area(sq.ft.) 937.00 0.11 0.00 0.00
Owner Name: D M VEN .• S FW CENTER LLC
Owner Address: 6725 .TH AVE NE SUITE 100
• AND WA 98033
B ' sing Official Date
The priori •cus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
ex..= nce has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible(within budgetary time and personnel limitations), the City neither guarantees
nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and/or occupant of the premises.
D.� 1 INSPECT OR RE:t AND T' PE OF I SI' "I It
,
a1411-t i4& . — saw, L b1 C ,:va o
461,-1 ,9N biag - 5, 106,1 0vt. -Ea mod/ Q, log e.t.a-k
t0124(r'i No rvs•w.iw - ,� hA �rK iicvk�!- I,ol� 's •
5 �
s ti C e t---#`11 cm.
triC 0.-A ��
F i pv-p s.i-or- N W Gwwdw 1146-t1
,
THIS CARD IS TO REMAIN ON-SITE ' ' '
Federal Wa Construction Inspection Record
y INSPECTION REQUESTS:(253)835-3050
PERMIT#: 17101879'00 Address: 2505 S 320TH ST
Project: D M VENTURES FW CENTER LLC FEDERAL WAY WA 98003-5461
Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card.
® Initial Erosion Control(4365) ® Footings/Setback(4110) 0 Foundation Wall(4115)
To be done PRIOR to breaking ground Approved to place concrete Approved to place concrete
By Date ! By Date By Date
1=1 Drainage/Downspout Drainage/Downspout(4040) 1=1 Re-steel(4215) El Slab/Concrete Floor(4255)
Approved to backfill Approved to place concrete or grout Approved to place concrete
By Date _By Date By Date
] Underfloor Framing(4285) ••Underfloor Floor Sheathing(4105) ..
•® Shear Walls(4245)
Approved to sheath floor Approved to install flooring Approved to install siding
•By Date By Date By Date
tvf
El Roof Sheathing(4220) Fire/Draft Stops(4095) El Interim Erosion Control(4370)
Approved to install roofmg Approved Approved
By Date .L By Date By Date
Prior to scheduling a Framing inspection; ® Framing(4120) ,f 14 Insulation(4150)
Electrical,Plumbing&Mechanical Rough-in Approved to insulate Approved to install wallboard
l
and Fire/Draft Stop inspections must be signed-
off and approved. IBC 109.3.4 By Date By Date
EI Gypsum Wallboard Nailing(4130) El Suspended Ceiling Grid(4265) El Final-SKF&R(4060)
Approved to install mud&tape rQ Approved to drop tile Approved
By Date By Date By Date
••
ElFinal-Planning ; El Final-Public Works(4080) � Final Erosion Control(4375) ,
Approved Approved Approved
By Date BY Date , By Date
El Final-Building(4050)
Approved
By Date 1) ) )Y •
•
El Rough Electrical 0 Final ElectricalD Right of Way
Approved Approved Approved
By Date By Date By Date
RECEIVED
•
CITYOP APR 2 6 2017 PERMIT APPLICATION
Federal WayPERM r CEWIEM+33325 8th Avenue South+Federal Way,WA 98003-6325
CITY OF FEDERAL WAY 253-835-2607+FAX 253-835-2609+permitcentei citvoffederalwav,com
COMMUNITY DEVELOPMENT
•
PsRI'mr NUMBER J _ J ®I GC) TARGET DATE 6/
71**“.'''.."'"-----)
SITE ADDRESS Federal Way Center, 2505 S 320th St, Federal Way, WA 98003 SUITE/UNIT#
PROJECT VALUATION ZONING ASSESSOR'S TA7l/PARCEL N
$ �1,J O K CC-C 797820 _ 0535_
TYPE OF PERMIT XI3unamo 13 PLUMBING ❑MECHANICAL ❑DEMOLITION 0 ENGINEERING 0 FIRE PREVENTION
NAME OF PROJECT Federal Way Center Building Upgrades
Interior:Finish,lighting,and ceiling upgrades. Replacement of stair and balcony guardrail.
PROJECT DESCRIPTION Site:Aesthetic upgrade to front and read of hulloing consisting of(2)new occupant
Detailed description of work to
be included on this permit only New exterior door,relocate existing trees affected by new work.
PROPERTY OWNER Mike Raskin 1)MOttv X425 8822 4466
MAIL/NG ADDRESS E-MAU.
MJR Development, 6725 116th Ave NE, Suite 100 mike@mjrdevelopment.com
Kirkland �/ WA 98033
N' fevora.�L 1 I�'4 C PHONE
ll B-MAn.
CONTRACTOR
CITY STATE Z8 FAX
WA STATE CONTRACTOR'S LICENSE S EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE/
NAME PHONE
Preston Welch 425-641-9200 ext 353
APPLICANT JPC ArcG h ADDRESS
909 112th Ave NE, Suite 206 prestonw@jpcarchitects.com
CITY STATE Z8 FAX
Bellevue WA 98004
PROJECT CONTACT
NAMEONE
PRIMARY Welch 425-641-9200 ext 353
(2'he individual to receive and NIHIL NO ADDRESS "MEL
respond to all correspondence JPC Architects, 909 112th Ave NE, Suite 206 prestonw@jpcarchitects.com
concerning this application) Bellevue WA 98004 FAX
NAME
PROJECT FINANCING Mike Raskin X OWNER FINANCED
When value is$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE
(RcW1927095) MJR Development. 6725 116th Ave NE. Suite 100 425-822-4466
X certify under penalty of perjury that I ant the property owner or authorised agent of the property owner.I certify that to the best
of my knowledge,the information submitted in support of this permit application is true and correct.I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorised by the issuance of a permit.I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Wag as to any claim(including costs,expenses,and attorneys'fees incurred in
the investigation and defense of such claim),which may be made by any person,including the undersigned,and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to ty as apart of this application.
SIGNATURE: / DATE 9/4/ f'vf'
PRINT NAME: 00/1 Y1161
Bulletin#100—January 29,2016 Page 1 of 2 k:\Handouts\Permit Application •
.. VALOR OF MECHANICAL WORK
MECHANICAL PERMIT $ Deferred submittal
Indicate how many of each type of fixture to be installed or relocated as part of this project Do not include existing fixtures to remain.
AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER(Describe)
AIR CONDITIONER FIREPLACE INSERTS HOODS(ce..e.,..h}
BOILERS FURNACES HOT WATER TANKS cons
COMPRESSORS GAS LOG SETS REFRIGERATION SYST
DUCTING GAS PIPING WOODSTOVES
•
VALUE OF PLUMBING WORK
PLUMBING PERMIT $ Deferred submittal
Indicate how many of each type of fixture to be installed or relocated as part of this project Do not include existing fixtures to remain.
BATHTUBS(or Tab/ShowerCombd LAVS(Hand Stoke) TOILETS WATER PIPING
DISHWASHERS RAINWATER SYSTEMS URINALS OTHER(Describe)
DRAINS SHOWERS VACUUM BREAKERS
DRINKING FOUNTAINS SINKS Mtdron ut apl WATER HEATERS(®etrid
HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES
—
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OP EXISTING!IMPROVEMENTS
No $
EXISTING/PREVIOUS USE LOT SIZE(In 8gnan Pang EXISTING FIRE SPRINKLER SYSTEM? PROPOSED IPME SUPPRESSION SYSTEM?
B (office) 5.68 acres XYes o No o Yes X No
I
RESIDENTIAL — NEW OR ADDITION
AREA DESCRIPTION(in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
�B E . ;. , « . :.-.1r
..na
....s r a _ .. fi . '^'rkmt4*..�hMil.: . cd .,w.
,
FIRST
FLOOR(or Mobile Home) y �y
, }7(! �""� >� + trt ^ai a ' Gk ay �.`'" .-�K,!#� :: t�k"*d,4,ry ,{°�`-'4, —� ..._.�..._._._....._._........_
:. .s..7:•<!1.9.1.V:.`''. NKV: Xat U. A x., ,S«... 1. ..a::.? ..:.sS j
COVERED ENTRY
DEOK �'t-rg'i t:t trp, '"t'" + s`'x$�" 0 S ti � 3s,! 14tt : t
GARAGE ❑ CARPORT ❑
i.--,11';..;,-:. ..
®A R PV ' 1 Y ',,s Z"t.i+ .tom+ '' 4 5: �r ' .r '''',• A, 5` 4. '45.. .._......._._r..._ _ _..._.....
,�I -, {�.�.ft1���T�.x:�'Nr'�<i.'*r« rim` .c. ..•�S". :x � , r;r,:
Area Totals
•' _ ` ,••r } :.•,a ii x*NEW 0.0** rONLY't'S_.. itaNAVA INSWIN
ESTIMATED SELLING PRICE$ I #OF BEDROOMS
COMMERCIAL—NEW/ADDITION
Are� F - . Construction
#of
AREA DESCRIPTION Occupancy Groups)
Additional Information
Square t TIP° Stories
'wan + F si ,rKt � ' ,ilrKGe- �s ' k •t � a- R � er � r � t
x `�4`�rIW'BIiDiNQ + itv�xii. d . ``t��K• +�3 .�� , geT ''t:11::,t ',c'4 _ u '� `'� t:•�ii.a0.jwba rgrY.. Mt �ty.dmsY44 �01 � `� }� Sx.Yt + g . Z. r`r :41 . omayS '
h
ADDITION 4,877 exterior site canopies/site
COMMERCIAL—REMODEL/TENANT IMPROVEMENTS amenities
Area'is Construction #of
AREA
AREA DESCRIPTION Occupancy Group(*)
Additional
Information ormation
Square Feet ��o Stories
.. „, . w�. }°,:, �. .agt_.3•. 4 'a1 .iti4y o Lsdin. e i.;� .irit l. A : {`t , . 7 "�;h
'...' .i;�Yso3:4n.g,. a ?Msf ... LklAit. :,s .?� •p0"zkr �x�,+;•a.r; x ?t'3 - E ,w _ k�r4= N 5.� 5l
.:)
..
r
TENANTAREAONLY 10,936 B (office) 1B 6 exist y
u %'. �: "4 a't"y ;,a"Rrt a+•>h;,r :3i.'f. i'4's' y.,re ' •',+; -r N'y+"g^; _„! h!-'F".�pj'-
^ . O JECT A_ AON i I`' i 'i ti-a r A s' " , ' �r.}i 4X51;��7f,` ..s irtz „ h:� , _ P r , 16' 1+of .
ox.. ;P , AREAO I.Y v v �a. '... , s.r riaiR'*"v`," ... ti .�c:..- ., . .�t:-r; �;-g•.<.".� i '1;1:55.4 s; z# '�2�5�...tX:
Bulletin#100—January 29,2016 Page 2 of 2 k:\Handouts\Pe>mit Application