Loading...
15-100518 Demolition City of Federal Way Permit #: 15-100518-00-DE Community Econ.& Dev.Services 33325 8th Ave S Federal Way,WA 98003 Ph:(253)835-2607 Fax (253)835-2609 Inspection Request Line: (253) 835-3050 Project Name: FEDERAL WAY HIG SC - SE I DEMOLITION Project Address: 30611 16TH AVE S Parcel Number: 082104 9001 Project Description: Demolition of southernmost portion of existing school building.separate fire alarm permit required Owner Applicant Contractor FEDERAL WAY PUBLIC SCHOOLS W M DICKSON CO W M DICKSON CO 33330 8TH AVE S 3315 S PINE ST WMDICC*108J7(4/1/15) FEDERAL WAY WA 98003 TACOMA WA 98409-5718 3315 S PINE ST TACOMA WA 98409-5718 Additional Permit Information Demolition Valuation 65000 PERMIT EXPIRES Thursday, February 16, 2017 Permit Issued on Tuesday, February 17, 2015 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: :1_,:)..e____ :41..,. a Date: %AV).L'-) I; THIS CARD IS TO REMAIN ON-SITE Fed �`� Construction Inspection Record eral Way INSPECTION REQUESTS: O 253 835-3050 PERMIT#: 15-100518-00-DE Address: 30611 16TH AVE S Project: FEDERAL WAY PUBLIC SCHOOLS FEDERAL WAY, WA 98003-4903 Scheduled inspections may be failed if this card is not on-site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible(read left to right,top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On-going inspections are logged on the back of this card. 0 Final-Building(4050) Approved jB /� Date _ / ( / __ t .El Rough ElectricalCI Final Electrical CI Right of Way Approved Approved Approved By Date By Date By Date t , • ID' ary or RECEIVED PERMIT APPLICATION Federal Way FEB 0 3 2015 OF FE W PERMIT NUMBER / — bC� - +.A / 1 r"'/ ('� / 5 1TARGET DATE / !!( SITE ADDRESS SUITE/UNIT# 30611 IP " 1 51 redeni �Av qt 3005 PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# $ ( ; O!O0ac2 0 R c / 0 V - 9 D 0 / TYPE OF PERMIT ❑ BUILDING ❑ PLUMBING ❑ MECHANICAL XI DEMOLITION�J❑ ENGINEER1NNG ❑ FIRE PREVENTION NAME OF PROJECT Fei�trec�l Way Cf 4. ',t o' l Si 1 t e&&o 1,4t'ON ne- i- '.- �e t)III!t'c9A e -I"f. SdLtf1 SO o-! Fh'I PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME i- PRIMARY PHONE PROPERTY OWNER I ett?i 'c.1 Way e' /1 C $'G LiS `:)t-;s--4(411 -4 a'5 7 MAILING ADDRESS E-MAIL 33 36 'f`' stat S y yS CITY r cY e rok UO`( STATE ZIP . 4- ' g 6(9 )/' PHONE/� !;3-4?) 'J ^ �,/// cy�� NAME yV livl V b t',k`O f. Cd N� eti _{ ;73- ?J-"l-1 0 MAILING ING ADDRESS 1 EMAIL CONTRACTOR J •S 1 S. �ru-e 5` t ('tr"L`,a.e W'v"L�l'Ch7/ 0✓t,ytci CITY STATE ZIP r • r c� FAX t0- CoN^A W14 QO 9SS`t? ' 1.16 1 WA STATE CONTRACTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# 11,,f3( b'J- e C .x « ' J Li /. NAMEPRIMARY PHONE e a- ela ,t,„,,4-o MAILING ADDRESS E-MAIL APPLICANT CITY STATE ZIP FAX PRIMARY PHONE i f / c� PROJECT CONTACT NAME iA `• ie ')C j'-9 77 )` '7 tl Q 1 MAILING ADDRESS MAIL respondThe individual to es pone and i 5 sP`�C 54 e� (6)��dIre °,l vt r to all correspondence T concerning this application) CITY„...-- STATE CO ST1 FAX E ZIP 8� q NAME PROJECT FINANCING °''l 6ZI OWNER-FINANCED Required value of$5,000 or more MAILING ADDRESS,CITY,STATE,ZIP PHONE (RCW 19.27.095) I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs,expenses, and attorneys'fees incurred in the investigation and defense of such claim), which may be made by any person,including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information su lied to the cit as a part of this application. SIGNATURE: DATE g/3/P-d (s PRINT NAME: e VA- a - te ti ///((( ITC w k k Bulletin#100—January 1,2013 Page 1 of 3 k:AI-Iandouts\Permit Application • • SEATTLE ASBESTOS TEST NVLAP Accreddation Lab Codes:200768 and 200876 • 19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 12727 Northup Way,Suite 1,Bellevue,WA 98005,Tel:425.861.1111,Fax:425.861.1118 Website:www.seattieasbestostest.com,Ernatadmin@seattleasbestostest.com PLM by Point Count(400 Points) Client Job#: 10527-01 r Attention: Mr.Herb Brod Laboratory Batch#: 201310869 Client: ENS International,Inc. Date Received: 4/22/2013 Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 7 Date Analyzed: 4/25/2013 Project: Federal Way High School, Block D Sample Requested for Point Count 10527-D-22 Previous Analytical Information Previously Analyzed by: Liz Dutton Previous Batch#: 201310552 Previous Lab ID: 22 Previous Description: White powdery material with paint Layer to be Point Counted: 1 Asbestos Type Found: Chrysotile Asbestos Percentage Found: 2 Point Count Analytical Procedures New Lab ID: 1 Asbestos Points Non-Asbestos Points Total Points Counted Slide 1 0 50 50 Slide 2 0 50 50 Slide 3 1 49 50 Slide 4 0 50 50 Slide 5 0 50 50 Slide 6 0 50 50 Slide 7 0 50 50 Slide 8 0 _ 50 50 Total 1 399 400 Point Count Summary Results Type of Asbestos: Chrysotile Percentage of Asbestos: 0.25% Analyzed By: Liz Dutton Reviewed by: Steve(Fanyao)Zhang, President 1 • • SEATTLE ASBESTOS TEST rtvLAp Rased5On Lab Codes:200768 and 200876 19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 • 12727 Northup Way,Suite 1,Bellevue,WA 98005,Tel:425.861.1111,Fax:425.861.1118 Website:www.seattleasbestostestcom,Email:admin@seattleasbestostesLcom PLM by Point Count(400 Points) Client Job#: 10527-01r Attention: Mr.Herb Brod Laboratory Batch#: 201310869 Client: EHS International,Inc. Date Received: 4/22/2013 Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 7 Date Analyzed: 4/25/2013 Project: Federal Way High School,Block D Sample Requested for Point Count 10527-D-24 Previous Analytical Information Previously Analyzed by: Liz Dutton Previous Batch#: 201310552 Previous Lab ID: 24 Previous Description: White powdery material with paint Layer to be Point Counted: 2 Asbestos Type Found: Chrysotile Asbestos Percentage Found: 2 Point Count Analytical Procedures New Lab ID: 2 Asbestos Points Non-Asbestos Points Total Points Counted Slide 1 0 50 50 Slide 2 0 50 50 Slide 3 1 49 50 Slide 4 1 49 50 Slide 5 0 50 50 Slide 6 0 50 50 Slide 7 0 50 50 Slide 8 0 50 50 Total 2 398 400 Point Count Summary Results Type of Asbestos: Chrysotile Percentage of Asbestos: 0.5% Analyzed By: Liz Dutton Reviewed by: Steve(Fanyao)Zhang,President 2 , , • . ëhsi 4 FHS-International, Inc. 13228 NE 20th Street, Suite 100 Bellevue, Washington 98005-2049 Phone 425-455-2959 Toll Free 800-666-2959 Fax 425-646 7247 LIMITED HAZARDOUS MATERIALS SURVEY REPORT FEDERAL WAY SCHOOL DISTRICT FEDERAL WAY HIGH SCHOOL 30611 - 16th Avenue South Federal Way, Washington i �_ • July 10, 2013 Prepared For: Federal Way School District c/o Jesse Ahlberg Greene Gasaway Architects 31620-23rd Ave. S. #207 Federal Way, WA 98003 • Environmental Engineering • Earth Sciences and Mapping • Industrial Hygiene Services • Construction Management 0 • ehs NI 4 . EHS-International, Inc. Limited Hazardous Materials Survey Report Federal Way High School 30611 - 16th Avenue South, Federal Way, Washington EHSI Project No. : # 10527 The material and data in this report were prepared under the supervision and direction of the undersigned. Report Approved By: // Herb Brod EHSI Hazardous Materials Services Manager ehsi4.0 ii EHS-International,Inc. ® • TABLE OF CONTENTS Acronym List iv 1.0 EXECUTIVE SUMMARY 1 1.1 BACKGROUND 1 1.2 EXTENT OF CURRENT SURVEY 1 1.3 MATERIALS FOUND 1 1.4 OPINIONS AND RECOMMENDATIONS 12 1.5 LIMITATIONS/DISCLAIMER 13 2.0 LIMITED HAZARDOUS MATERIALS SURVEY REPORT14 2.1 BACKGROUND 14 2.2 BUILDING DESCRIPTION 14 2.3 SAMPLING METHODOLOGY 16 2.3.1 Asbestos-Containing Materials 16 2.3.2 Lead-Containing Paint/Lead-Containing Materials 17 2.3.3 Arsenic-Containing Materials 17 2.4 SAMPLING RESULTS 17 2.4.1 Asbestos-Containing Materials 17 2.4.2 Lead-Containing Paint and Building Materials 118 2.4.3 Arsenic-Containing Building Materials 151 2.4.4 Toxic Characteristic Leaching Procedure Sampling 151 2.4.5 Polychlorinated Biphenyls 152 2.4.6 Mercury-Containing Fluorescent Light Tubes 152 3.0 LIMITATIONS 156 4.0 STANDARD OF CARE 157 5.0 CERTIFIED AHERA BUILDING INSPECTORS 157 APPENDICES A Asbestos Analytical Laboratory Report and Field Data Forms B Lead and Arsenic Laboratory Reports and Field Data Forms C Certified AHERA Building Inspector Certificates D Laboratory Certifications for Asbestos, Lead, and Arsenic Analysis E Sample Location Drawings for Asbestos, Lead, and Arsenic ehsi alb EHS-International,Inc. • ACRONYM LIST ACM Asbestos-Containing Material ACT Acoustic Ceiling Tiles AHERA Asbestos Hazard Emergency Response Act AHU Air Handling Unit AIHA American Industrial Hygiene Association As Arsenic BMU Brick Masonry Unit CAB Cement Asbestos Board CB Cove Base CFR Code of Federal Regulations DOSH Washington State Department of Labor and Industries, Division of Occupational Safety and Health EA Each Ecology Washington State Department of Ecology EFIS Exterior Finishing Insulation System EHSI EHS-International, Inc. ELLAP Environmental Lead Laboratory Accreditation Program GWB Gypsum Wall Board Hg Mercury JC Joint Compound LCM Lead-Containing Material LCP Lead-Containing Paint L&I Washington State Department of Labor and Industries mg/L Milligrams Per Liter mg/m3 Milligrams Per Cubic Meter N/A Not Applicable ND None Detected NVL NVL Laboratories, Inc. NVLAP National Voluntary Laboratory Accreditation Program OSHA US Occupational Safety and Health Administration Pb Lead PCBs Polychlorinated Biphenyls PLM Polarized Light Microscopy ppm Parts per Million PSCAA Puget Sound Clean Air Agency QA Quality Assurance RCW Revised Code of Washington SACT Suspended Acoustical Ceiling Tiles SAT Seattle Asbestos Test, LLC SF Square Feet SVF Sheet Vinyl Flooring TCLP Toxic Characteristic Leachate Procedure TSI Thermal System Insulation VAT Vinyl Asbestos Tile VCT Vinyl Composite Tile WAC Washington Administrative Code WT Weight w/ With XRF x-ray fluorescence ehsi4 iv EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 1.0 EXECUTIVE SUMMARY 1.1 BACKGROUND Federal Way School District (FWSD) has contracted Greene Gasaway Architects (GGA) to lead the design team for the Federal Way High School demolition project, located at 30611- 16th Avenue South, Federal Way, Washington. In conjunction with that project FWSD contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Hazardous Materials Survey of the Federal Way High School. The intent of the survey is to specifically identify and quantify asbestos-containing building materials (ACM), lead-containing paint (LCP), other lead-containing building materials (LCM), arsenic-containing brick masonry unit (BMU) mortar, polychlorinated biphenyl (PCB)-containing light ballasts, and mercury (Hg)-containing light tubes and lamps that may be impacted by the Project. 1.2 EXTENT OF CURRENT SURVEY EHSI inspected all accessible interior and exterior materials potentially impacted by the proposed project. Accessible suspect materials were sampled including, but not limited to; interior and exterior wall systems, ceiling and floor systems, mechanical systems, windows, and roofing materials. EHSI accomplished representative destructive inspection; however, in areas inaccessible for inspection (e.g., fire door cores, casework mastics, chalk/cork/dry erase board, mirror and student locker mastics, enclosed plaster wall chases, electrical panel components, boiler internals and materials above hard lid ceilings) suspect materials were assumed to be ACM. 1.3 MATERIALS FOUND SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION Block A Multiple layers of ACM black asphaltic built up roofing with ACM tar on non ACM brown fibrous Interstitial Space above Boy's Locker Room insulation on ACM black asphaltic vapor barrier on wood Non-ACM 12"x12" VCT w/ non-ACM yellow mastic on non-ACM gray leveling compound on Gym Corridor ACM black mastic on concrete ACM brown stair tread on non-ACM green, 2nd Floor Stairwell 1 and 2 brown, and yellow mastic on wood ACM brown SVF stair landing on non-ACM yellow 2nd Floor Stairwell 1 and 2 mastic on wood ACM 8" stair stringer w/ non-ACM brown mastic 2nd Floor Stairwell 1 and 2 ehsi.. EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION Carpet w/ non-ACM yellow carpet mastic on 9"x9" burnt orange VAT w/ non-ACM black Marketing A75 mastic on concrete Carpet w/ non-ACM yellow carpet mastic on non- ACM gray leveling compound on 9"x9" burnt Marketing A75 Storage A76 and A77 orange VAT w/ non-ACM black mastic on concrete Blue carpet w/ non-ACM yellow carpet mastic on non-ACM gray leveling compound on ACM ASB A5 residual black mastic on concrete Hard wood floor w/ non-ACM brown paper vapor barrier w/ non-ACM black asphaltic backing on hardwood floor sleepers on ACM multi-layered Main Gymnasium black asphaltic vapor barrier beneath tarred to concrete Lockers A10, Lockers A24, Exercise A33, Assumed ACM white board mastic Training A38, Lockers A50/A60, and marketing A75 Assumed ACM tack board mastic Marketing A75 Assumed ACM cabinet mastic Weights A39 Assumed ACM mirror mastic Boy's and Girl's Locker Rooms, Weight Room A39, and Restroom Assumed ACM electrical panel backing Mechanical Room Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Block B Non-ACM 12"x12" blue VCT w/ non-ACM yellow Cafeteria B1/B2 mastic on ACM residual black mastic on concrete ACM Gray window glazing putty on 4'x5' windows Corridor B5 Non-ACM 4"tan/gray CB w/ non-ACM crème colored mastic on ACM residual brown mastic on Corridor B5 concrete ACM Gray window glazing putty on 4'x3' Cafeteria B2 clearstory windows Assumed ACM mirror mastic Kitchen Restroom, Kitchen 5-9 Assumed ACM white board mastic Throughout Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Block C ehs .i EHS-International,Inc. 2 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION ACM black sink undercoat Faculty Lounge Non-ACM 12"x12" blue VCT w/ non-ACM yellow Original Building mastic on non-ACM gray leveling compound on Corridor C-116 ACM residual black mastic on concrete Non-ACM 12"x12" light gray VCT w/ non-ACM yellow/tan mastic on non-ACM gray leveling Original Building compound on 9"x9" black VAT w/ ACM black Corridor C-116 mastic on concrete Non-ACM 12"x12" off-white VCT (w/ brown, yellow, and white streaks) w/ non-ACM yellow Original Building Passage C-115 mastic on non-ACM gray leveling compound on ACM residual black mastic on concrete Carpet w/ non-ACM beige and yellow carpet mastic on 12"x12" off-white non-ACM VCT (w/ Original Building brown, yellow, and white streaks) w/ non ACM Copy C-111, Data Processing, Conference C- yellow mastic on non-ACM gray leveling 108 compound on ACM residual black mastic on concrete Non-ACM light gray SVF (w/ broken rock pattern) w/ non-ACM brown paper backing w/ non-ACM mastic on non-ACM gray/brown Janitor C-110 leveling compound on ACM residual black mastic on concrete Blue carpet w/ non-ACM yellow/brown mastic on non-ACM gray leveling compound on ACM Original Building C-107 residual black mastic on concrete Carpet w/non-ACM yellow/tan mastic on non- ACM gray leveling compound on 9"x9" black VAT Original Building Girls C-135 w/ ACM black mastic on concrete Non-ACM orange SVF (with yellow and brown streaks) with non-ACM yellow mastic w/ ACM Original Building 2nd Floor Janitor Closet C- gray paper backing on ACM residual black mastic 217 on concrete Non-ACM light gray SVF (w/ broken rock pattern) with non-ACM beige paper backing and Original Building 2nd Floor Storage C-218 non-ACM beige mastic w/ 9"x9" black VAT w/ ACM black mastic on concrete Non-ACM 12"x12" off-white VCT (w/ brown, yellow, and white streaks) with non-ACM yellow Original Building 2nd Floor Corridor C-216 mastic on non-ACM gray leveling compound on 9"x9" black VAT w/ ACM black mastic on wood Carpet with non-ACM yellow mastic on 9"x9" Original Building 2nd Floor E. Classroom C- dark red VAT w/ ACM black mastic on wood 206 ehsieb. EHS-International,Inc. • i Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION Carpet with non-ACM yellow/brown mastic on ACM residual black mastic on non-ACM Original Building 2nd Floor E. Classroom C- fiberboard with non-ACM clear coat on hard 206 wood floor on non-ACM black vapor barrier ACM NicoliteTM in wood fire wall Original Building Attic ACM Black asphaltic sealant at vent penetration Original Building Attic ACM MAG TSI pipe run (<6" OD) in wall Original Building 2nd Floor Room Replacement of Stairs Carpet with non-ACM yellow mastic on 9"x9" Building Addition 2nd Floor E. Classroom C- Carpet VAT w/ ACM black mastic on wood 211, C 212, C 213, C 215, and Corridor C 214 Non-ACM 12"x12" off-white VCT (w/ brown, yellow and white streaks) w/ non-ACM yellow Building Addition 1st Floor Nurse C-126 and mastic on non-ACM gray leveling compound on Office C-128 ACM residual black mastic on concrete Carpet w/ non-ACM yellow mastic on 9"x9" off Building Addition 1st Floor Vice Principal C- white and gray VAT w/ ACM black mastic on 125 and Clerical C-122 concrete Carpet w/ non-ACM yellow carpet mastic on non- ACM gray leveling compound on ACM residual Waiting C-129 black mastic on concrete 2nd Floor Original Building E. Classroom C- 201-208, Stairwell replacement classroom, Listening C-210 1st Floor Building Addition, Assumed ACM white board mastic V.P. 123, 124, 125, Principal C-120, Conference C-119, 2nd Floor Building Addition Computers C-212, E. Classroom C- 211,213 and C-205 Assumed ACM tack board mastic 2nd floor Original Building E. Classroom C- 206 1st Floor Building Addition 1st Floor Building Addition, V.P. 123, 124, 125, Principal C- 120, Conference C-119, Waiting C-129, ATT Assumed ACM mastic associated with wood wall C132, BKPR C 131, Work C 130, Wait C paneling 121, 2nd Floor Original Building E. Classroom C-201-208, Stairwell replacement classroom, 2nd Floor Building Addition Computers C-212, E. Classroom C-211,213 and C-205 2nd Floor Original Building E. Classroom C- Assumed ACM cabinet mastic 201-C-208 2nd Floor Building Addition Computers C- 212, E. Classroom C-211,213 and C-205 ehsi EHS-International.Inc. 4 • I Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION Assumed ACM locker mastic 2nd Floor Original Building Corridor C-216 1st Floor Original Building Girls C-135, and Assumed ACM mirror mastic 2nd Floor Original Building C-220 Assumed ACM electrical panels and components 1st Floor Boiler Room and 2nd Floor C-127 Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Block D Library D-15, Conference D-16 Audio Video Blue carpet with non ACM yellow/tan mastic on Classroom D-17, Alcove D-18, Work Room ACM residual black mastic on concrete D-19 and Magazine D-20 1 White NicloliteTM paper in wood fire wall Library Attic Non-ACM silver paint on ACM black asphaltic Library Attic tar/sealant Carpet w/ non-ACM gray foam carpet backing w/ non-ACM clear mastic on non-ACM 12"x12" off- white VCT (w/ brown, yellow, and white streaks) Corridor D-14 w/ non-ACM yellow mastic on ACM residual black mastic on concrete Carpet with non-ACM brown and orange mastic on 9"x9"tan VAT (w/ white and brown streaks) Corridor D-14 w/ ACM black mastic on concrete Carpet w/ non-ACM gray foam carpet backing w/ non-ACM clear/yellow mastic on ACM residual Corridor D-13 black mastic on concrete ACM black sink undercoat Office D-11 Assumed ACM white board mastic A.V. Classroom D-17, Conference D-16, S.S. Classrooms D-1-D-8 Assumed ACM tack board mastic Library D-15, Assumed ACM mastic associated with wood wall Library D-15, A.V. Classroom D-17, Corridor paneling D-14 and Classrooms D-1-D-8 Assumed ACM mastic associated with wall Library D-15 and Office D-11 and mounted book cases Library D-15, A.V. Classroom D-17, Corridor Assumed ACM mastic associated with casework D-14, MAG D-20,and Storage Assumed ACM univent internals Library Assumed ACM locker mastic Corridor D-14 Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Block E Non-ACM 12"x12" light gray VCT with non-ACM off-white and yellow mastic on ACM residual Corridor E-8 black mastic on concrete ehsi. 5 EHS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION Non-ACM 12"x12" blue VCT with non-ACM yellow Corridor E-8 mastic on ACM residual black mastic on concrete Carpet with non-ACM yellow mastic on ACM Vestibule E-25 residual black mastic on concrete Carpet with non-ACM yellow mastic on 9"x9" Social Studies Classroom E-21 light blue VAT w/ ACM black mastic on concrete 9"x9" Light brown VAT with ACM black mastic on Theater E-10 and Control E-11 concrete Carpet with non ACM yellow and orange mastic Drama Classroom E-1, Green Room E-7 and on 9"x9"tan VAT w/ ACM black mastic on Dressing E-5 concrete Drama Classroom E-1, Passage E-2, and Assumed ACM white board mastic Classroom E-17 2001 Addition Classrooms 1-5 Assumed ACM mastic associated with wood wall Drama Classroom E-1, Green Room E-7, paneling; S.S. Classroom E-21, and Classroom E-17 Assumed ACM mastic associated with wall panels Corridor E-8 Assumed ACM wiring associated with theatre Theater stage lighting Assumed ACM mirror mastic Women E-4 Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Block F Non-ACM 12"x12" off-white VCT (with brown, Laundry F 2, Storage F 3, Cooking F 4, yellow, and white streaks) w/ non-ACM yellow Office F 5, Dress F-6, Storage F 7, Sewing mastic on ACM residual black mastic on F-8, Storage and Child Development F-11 concrete 9"x9"Tan VAT (with brown and yellow streaks) Electrical F-1 w/ ACM black mastic on concrete 9"x9" Light brown VAT (w/ rainbow streaks) w/ Electrical F-1 ACM black mastic on concrete 9"x9" Olive green VAT w/ ACM black mastic on Biology Classroom 1 and 2 concrete 9"x9" Brown/red VAT (with beige streaks) w/ Storage F-17 and F-18 ACM black mastic on concrete Carpet w/ non-ACM clear mastic on 12"x12" beige VAT (with brown streaks) on ACM black Electronics F-19 and Drafting F-16 mastic on concrete Carpet with non-ACM yellow mastic on"x9" red Special Education F-13 VAT w/ ACM black mastic on concrete ehs 4.i EHS-International,Inc. 6 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION Carpet w/ non-ACM green/gray mastic w/ non- ACM yellow mastic on 9"x9" light brown VAT (w/ Special Education F-15 rainbow streaks) w/ ACM black mastic on concrete ACM black sink undercoat Sewing F-8, Electronics F-19 and Drafting F- 16 Assumed ACM mastic associated with wood wall Cooking F 4, Sewing F 8, Child development paneling F-11, Special Ed F-13,15, Drafting F-16, Electronics F-19, and Biology Classroom's Assumed ACM wall panel mastic Corridor F-9, 10, and 15 Cooking F-4, Sewing F-8, Child development Assumed ACM white board mastic F-11, Special Ed F-13,15, Drafting F-16, Electronics F-19, and Biology Classroom's Assumed ACM tack board mastic Special Ed F-13, Corridor F-15 Assumed ACM mirror mastic Toilet F-12 Cooking F-4, Sewing F-8, Child development Assumed ACM mastic associated with casework F-11, Special Ed F 13,15, Drafting F 16, Electronics F-19, and Biology Classroom's, Storage F-17 and 18, Biology Prep Rooms Assumed ACM locker mastic Corridor F-9, 10, and 15 Assumed ACM electrical panels and components Mechanical Room and Electrical F-1 Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Block G Non-ACM 12"x12" light gray VCT (with white and gray streaks), blue VAT, and gray VAT (w/ maroon streaks) all w/ non-ACM tan mastic on Corridor G-13 non-ACM white leveling compound on ACM gray VAT w/ ACM black mastic on wood Blue/gray carpet with non-ACM tan mastic on Janitor G-9, Storage G-10A, Storage G-11, tan VAT w/ ACM black mastic on wood and Storage G-3 Conference G-2A, Classroom G-2, Blue/gray carpet with non-ACM tan mastic on Simulators G-1, Business Classroom G-4, gray VAT w/ ACM black mastic on wood Computer G-5, Keyboard Classroom G-6, and Micro Computer G-7 Corridor G-13, Conference G-2A, Classroom Assumed ACM mastic associated with wood wall G-2, Simulators G-1, Business Classroom G- paneling 4, Computer G-5, Keyboard Classroom G-6, and Micro Computer G-7 Conference G-2A, Classroom G-2, Assumed ACM mastic associated with casework Simulators G 1, Business Classroom G 4, Computer G-5, Keyboard Classroom G-6, and Micro Computer G-7 ehSiw EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION Classroom G-2, Simulators G-1, Business Assumed ACM white board mastic Classroom G-4, Computer G-5, Keyboard Classroom G-6, and Micro Computer G-7 Assumed ACM locker mastic Corridor G-13 Assumed ACM electrical panels and components Business Office G-10 Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Block H Non-ACM 12"x12" beige VCT (w/ brown and Main Corridor, Room 704,705, and Office white streaks) w/ ACM black mastic on concrete Area Non-ACM white leveling compound on non-ACM gray leveling compound on ACM residual black Janitor's Closet mastic on concrete Multi-colored carpet w/ non-ACM foam backing w/ non-ACM clear mastic on non-ACM 12"x12" beige VCT (w/ brown and white streaks) w/ ACM ASA Room black mastic on concrete Assumed ACM mastic associated with wood wall paneling ASA Room Assumed ACM white board mastic ASA Room, Room 704 and 705 Assumed ACM tack board mastic ASA Room, Room 704 and 705 Assumed ACM mastic associated with casework ASA Room, Room 704 and 705 Assumed ACM locker mastic Main Corridor Assumed ACM electrical panels and components Main Corridor Assumed ACM mirror mastic Grooming, Boy's Restroom and Girl's Restroom Assumed ACM fume hood baffles and internals Room 704 and 705 Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Block ] Carpet w/ non-ACM yellow mastic on 9"x9" Math Classroom J-5 and J-8 1 brown/red VAT w/ non-ACM mastic on concrete Non-ACM 12"x12" light gray VCT w/ non-ACM dark gray mastic on 9"x9" light blue VAT (w/ Corridor J-2 and 3-11 2 white streaks) w/ black mastic on concrete Carpet w/ non-ACM yellow mastic on 9"x9" tan VAT (w/ brown and yellow streaks) w/ non-ACM Math Classroom J-7 and Health J-10 3 black mastic on concrete 9"x9" Red VAT on ACM black mastic beneath non-ACM carpet with non-ACM carpet mastic on Math Classroom J-9 and J-6 4 concrete Assumed ACM mastic associated with wood wall Corridor J-2, Math Classroom J-5, J-6, J-7, paneling 3-8, J-9, Health 3-10 5 ehs . EHS-International,Inc. 8 • • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION Assumed ACM wall panel mastic Corridor J-2 and J-11 6 Assumed ACM tack board mastic Math Classroom J-9, Health J-10 7 Assumed ACM white board mastic Math Classroom J 5, J 6, J 7, J 8, J 9, Health 3-10 8 Assumed ACM locker mastic Corridor J-11 Assumed ACM mirror mastic Girls Restroom Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Block K Carpet w/ non-ACM yellow/tan mastic on 9"x9" F.L. Classroom K 1, K 2, Math Office K-2 red VAT w/ non-ACM black mastic on concrete 9"x9"Tan floor tile with brown and yellow streaks on non-ACM black mastic beneath non F.L. Classroom K-9 ACM carpet on non-ACM yellow mastic on concrete 9"x9" Brown/red floor tile with beige streaks on F.L. Office K-6 and Conference K-7 ACM black mastic on concrete Non-ACM 12"x12" dark gray floor tile on non- ACM yellow mastic on 9"x9" light blue VAT on Corridor K-5 ACM black mastic on concrete F.L. Classroom K-1, Computer K-3, Math Assumed ACM mastic associated with wood wall Classroom K-8, F.L. Classroom K-9, F.L paneling Office K-6, Conference K-7, F.L. Classroom K-4, Math K-2 Assumed ACM wall panel mastic Corridor K-5 Assumed ACM tack board mastic Computer K-3 F.L. Classroom K-1, Computer K-3, Math Assumed ACM white board mastic Classroom K-8, F.L. Classroom K-9, F.L Office K-6, Conference K-7, F.L. Classroom K-4, Math K-2 Assumed ACM locker mastic Corridor K-5 Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) 9"x9" Olive and light olive colored VAT w/ ACM Ceramics Lab L-5 black mastic on concrete Block L 9"x9" Green VAT (w/ beige streaks) w/ ACM Art Lab L-1 black mastic on concrete Blue/gray carpet w/ non-ACM tan mastic on non- ACM white leveling compound on 9"x9" red VAT Office L-8 w/ ACM black mastic on concrete 110eh9 EHS-International,Inc. i • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 • July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION Non-ACM red sheet vinyl flooring with non-ACM black asphaltic backing on ACM black mastic on Metal Shop L-13 and Office L-9 concrete ACM gray caulking around metal seismic wall brackets Corridor L-6 Assumed ACM mastic associated with wood wall Art Lab L-1, Ceramics Lab L-5, Storage L-3 paneling and L-4 6 Assumed ACM mastic associated with casework Art Lab L-1 Assumed ACM electrical panels and components Metal Shop L-13 Assumed ACM tack board mastic Office L-2 Assumed ACM white board mastic Art Lab L-land Shop Classroom L-7 Assumed ACM locker mastic Corridor L-6 Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Block M 9"x9" Olive colored VAT (w/ pink and beige streaks) w/ ACM black mastic on concrete Choral M-26 Non-ACM 12"x12" blue VCT w/ non-ACM yellow Corridor M-1 and Corridor M-12 mastic on ACM residual black mastic on concrete Non-ACM blue/gray carpet w/ non-ACM tan mastic on 9"x9" Olive colored VAT (w/ pink and Passage M-28, Practice 3, M-29, and M-31 beige streaks) w/ ACM black mastic on concrete Non-ACM blue/gray carpet w/ non-ACM tan Ensemble M 13, Practice M 14, Practice M mastic on 9"x9" red VAT w/ non-ACM black 15, Instrument M 19, Office M 20, Storage mastic on concrete M-22, Library M-23, Storage M-24, Office M- 25 Non-ACM 12"x12" light gray VCT (w/ maroon Storage M-2, Mechanical M-5, Office/Lab M- and white streaks) w/ ACM black mastic on 9, Storage M-34, Film M-35, Print M-36, concrete Print M-37, Photo Lab M-38 9"x9"Yellow floor tile (w/ brown and black Science Classroom M-11 streaks) w/ ACM black mastic on concrete Assumed ACM mastic associated with wood wall Physics Lab M 7, Chemistry Lab M-6 Band paneling M-17, Office M-20, Storage M-22, Photo Lab M-38 Physics Lab M-7 and associated Offices, Chemistry Lab M-6, Office Lab M-9, Science Classroom M-11, Ensemble M-13, Assumed ACM mastic associated with casework Instrument Storage M-19, Office M-20, Storage M-22, Library M-23,Office M-25, Storage M-34, Film M-35, Print M-36, and Photo Lab M-38 Assumed ACM locker mastic Corridor M-12 Physics Lab M-7, Chemistry Lab M-6, Assumed ACM white board mastic Science Classroom M-11, Band M-17,Entry M-18 Choral M-26, Photo Lab M-38 ehs . 10 EHS-International,Inc. • 1 Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION Assumed ACM fume hood baffles and internals Physics Lab M 7, Chemistry Office/Lab M 9, Science Classroom M-11, Assumed ACM fire doors Throughout Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Tunnels ACM TSI debris, at floor penetration (4"OD pipe Utility Tunnel L/M NW End run) ACM Army green/gray cable bracket mastic Utility Tunnel L/M, at tunnel Hatch ACM Black asphaltic vapor barrier between Utility Tunnel A/B concrete and wood forms ACM TSI on abandon 8" pipe run Utility Tunnel A/B JC on crawl space access door (3'x3') Block G Crawl Space Exterior ACM White caulking on steel columns Exterior Block L/M ACM gray roll-up door frame caulking (8'x14') Exterior Block L ACM tan/gray door frame caulking (8'x14') Exterior Block F ACM tan window frame caulking (3'x5') Exterior Block F ACM gray window frame caulking (3'x5') Exterior Block M ACM black asphaltic tar beneath non-ACM black Block C Foundation asphaltic felt on concrete foundation wall Roof ACM Silver coat on ACM black asphaltic tar on metal roof vent base Block A Roof ACM Silver coat on ACM asphaltic built up roofing on non ACM asphaltic vapor barrier on non-ACM Block C Roof brown paper vapor barrier on wood roof deck ACM black asphaltic sealant on parapet wall Block D Roof flashing ACM Black asphaltic lead vent pipe penetration sealant Block M Roof ACM Silver coat on non-ACM built-up roofing on non-ACM black asphaltic vapor barrier on non- Block M Roof ACM asphaltic tar on concrete ACM black asphaltic sealant on non-ACM black asphaltic built-up roofing with tar beneath non- Block M Roof ACM silver coat ACM Black asphaltic tar on ACM built-up roofing on non-ACM black asphaltic vapor barrier on P1 Roof non-ACM brown paper vapor barrier on wood roof deck ACM black asphaltic roof repair patch P1 Roof Covered Walkways I I EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL DESCRIPTION LOCATION ACM Black asphaltic coating beneath non-ACM Center Courtyard beige and white paint Portables (P1) ACM White wall cover backing Interior Walls ACM gray window frame glazing putty (4'x8') Exterior Windows and (3'x4') Assumed ACM electrical panels and components Classroom Assumed ACM chalkboard mastic Classroom Community Pool Non-ACM dark blue rubber flooring with non- ACM white/beige mastic on tan VAT w/ ACM Office and Lobby 1 black mastic on concrete ACM white cloth flex duct (4'x4') Boiler Room 2 ACM red seam sealant on ACM black sealant (on Boiler Room 3 AHU) ACM silver paint on boiler exterior Boiler Room 4 ACM TSI on boiler exhaust duct (2'diameter) Boiler Room 5 ACM brown/black glue dots associated with fiber Office 6 board wall panel (4'x8') ACM white cloth flex duct (3'x3') Men's and Women's Locker Room Attic 7 AHU with assumed ACM internal components Boiler Room 8 Assumed ACM electrical panels Boiler Room and Boiler Room Office 9 Assumed ACM fire doors Throughout Assumed ACM flange gaskets (associated with the boiler); Boiler Room Assumed ACM boiler internal components Boiler Room Assumed ACM wall panels and associated mastic (High bay pool area); Over Pool Assumed ACM TSI on small bore pipe runs and Throughout fitting (concealed in plumbing walls and ceilings) Assumed ACM TSI on large bore pipe runs and Under concrete slab fittings under slab (associated with pool). 1.4 OPINIONS AND RECOMMENDATIONS This will be a full demolition, therefore, EHSI recommends that all ACM and assumed ACM identified in paragraph 1.3 be removed and disposed prior to demolition/renovation. Any suspect materials not identified as having been surveyed in this report must be treated as an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP certified laboratory. Washington State Department of Labor and Industries (L&I) Division of Occupational Safety and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require • e s .� 12 EHS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of lead and arsenic. Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead-containing paint, the contractor should perform an initial exposure assessment to determine if personal protective measures and work practices are required. With the exception of ceramic tile, porcelain bathroom fixtures and painted metal, based on the relatively low concentrations of lead in the paint and absence of arsenic in the brick/CMU mortar and the known scope of work (e.g., demolition), EHSI does not anticipate exposure monitoring results will exceed the DOSH action level of 30 milligram per cubic meter (mg/m3) for lead or 0.01 milligrams per cubic meter (mg/m3) for arsenic. Special care should be taken to reduce potential employee exposure to lead when demolishing ceramic tile, porcelain bathroom fixtures and painted metal, including reducing airborne dust (e.g., water misting and use of hand tools, or demolition from a distance {backhoe}). Fluorescent light fixtures within the scope of work have magnetic ballasts. Magnetic fluorescent light ballasts that will be disturbed during the demolition project are assumed to contain greater than two parts per million (> 2 ppm) PCB-dielectric oil and must be disposed or recycled as Washington Department of Ecology (Ecology) Dangerous Waste. In addition, all fluorescent tubes and lamps contain mercury. Any fluorescent lamps/tubes to be disturbed during the project must be recycled as Washington Department of Ecology (Ecology) Universal Waste. 1.5 LIMITATIONS/DISCLAIMER This report does not represent a comprehensive hazardous materials investigation for the subject property. This investigation has been conducted by EHSI under a specific scope of work authorized by the FWSD for a specific purpose. Fire door cores, casework mastics, chalk/cork/dry erase board, mirror and student locker mastics, enclosed plaster wall chases, electrical panel components, boiler internals, and materials above hard lid ceilings were not sampled and are assumed to be ACMs. This report and accompanying appendices include the supporting information for this executive summary. ehsi EHS-International,Inc. 13 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 2.0 LIMITED HAZARDOUS MATERIALS SURVEY REPORT 2.1 BACKGROUND The Federal Way Public Schools District (District) plans to replace the existing Federal Way High School with a new school on the same site. The District has contracted Greene Gasaway Architects to manage this project and contracted the SRG Partnership (SRG) to lead the design team. In conjunction with this project, the District contracted EHS- International, Inc. (EHSI), a hazardous materials and environmental consulting firm, to accomplish a pre-demolition limited hazardous materials survey of the existing structures on the site, with the exception of playing fields and field houses, and to accomplish an assessment of existing underground heating oil storage tanks (USTs) on the site. The UST assessments will be provided under a separate cover. For the limited hazardous materials survey, EHSI was tasked to use applicable federal, state, and local guidelines in the accomplishment of its survey. EHSI was further tasked to provide a written survey report including: identification of all suspect materials; a determination of whether suspect materials were: asbestos-containing materials (ACM), lead-containing paint (LCP), lead- containing materials (LCM), Arsenic (As)-containing brick/concrete masonry unit (CMU) mortar, polychlorinated biphenyl (PCB)-containing light ballasts and transformers, or Mercury (Hg)-containing light tubes/lamps, thermostats and switches; and to provide analytical reports indicating the presence and quantity of the hazardous materials. This Limited Hazardous Materials Survey Report meets the Washington State "Good Faith Survey" requirements as cited in Revised Code of Washington (RCW) 49.26.016 and implemented by Department of Labor and Industries Division of Occupational Safety and Health (L&I DOSH) regulation, Washington Administrative Code (WAC) 296-62-07721, and Regulation III, Article 4 of the Puget Sound Clean Air Agency (PSCAA). On April 1st - 19th and June 25th, 2013, EHSI conducted a Limited Hazardous Materials (ACM, LCP, LCM, As, PCB or Hg-containing) Survey of wings A through M, including roofs, attics, crawlspaces, basements and covered walkways; two portable classroom buildings P1 & P2; and the "Community Pool" building on the Federal Way High School campus. 2.2 BUILDING DESCRIPTION The Federal Way High School is located at 30611-16th Avenue South, Federal Way, Washington. The original building was constructed in 1937 with additions, modernization projects and new building construction in 1944, 1952, 1957, 1962, 1972, 1975, 1985, and 2001. The original 1937 (Block C) Building is a two-story structure constructed of brick masonry units (BMU) on a concrete foundation with wood framed interior walls. The roof is a sloped three-tab roof on wood decking. Interior walls include: plaster and GWB walls (the GWB walls have replaced original plaster walls located throughout the 1st and 2nd floor library). Other interior finishes include: vinyl or wood cove base (CB) throughout. Flooring includes: Vinyl composite tiles (VCT) and vinyl asbestos tiles (VAT) on black mastic on wood and concrete. Ceilings include: Plaster "hard-lid" and GWB "hard-lid", suspended acoustic ceiling tiles and acoustic tiles glued onto GWB. Windows are operable and non-operable metal- ehsi4 14 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 framed. In 1944, a two-story structure was added to the original building consisting of the same building materials. A natural gas boiler located in the 1st floor boiler room provides hot water to this block. A central HVAC system located in the attic space provides forced air heating and air conditioning. The 1952 (Block A/B) Building is a one-story structure constructed of concrete and concrete masonry units (CMU) on concrete foundation. The building houses the main gym, auxiliary gym, locker rooms and cafeteria. In 1965, the building went through renovations adding another locker room and a second floor exercise room. In 2001, Block B went through a renovation adding a commons area to the cafeteria. The roof is flat with the exception of the main gym roof which is gambrel roof, all on wood decking. Interior walls include: CMU, plaster, GWB and ceramic wall tile walls. Other interior finishes include: vinyl cove base. Flooring includes: bare and painted concrete, 12"x12" VCT, 9"x9" VAT, ceramic tiles, hard wood flooring, carpet, carpet on VCT/VAT and concrete. Ceilings include: Plaster "hard-lid", GWB "hard-lid", acoustical ceiling tiles (ACT) glued-on GWB, and suspended acoustic ceiling tiles (SACT). There is spray applied fireproofing on structural elements above the ceilings. Clearstory windows provide light in the main gym and fluorescent fixtures provide light throughout the rest of the building. A natural gas boiler located in a boiler room below grade provides hot water to these two blocks. A central HVAC system provides forced air heating and air conditioning. Block L/M Building was originally constructed in 1957 and renovated in 1971 and 1975. The building is a one-story structure housing industrial arts and sciences classrooms/labs. Exterior walls are made of BMU, CMU and concrete, all on a concrete foundation. The roof is slightly sloped on wood decking. Interior wall finishes include: BMU GWB, and plaster walls. Other interior finishes include: vinyl CB throughout. Flooring includes: 12"x12" VCT, 9"x9" VAT, carpet on 9"x9" VAT, carpet on 12"x12" VCT, and carpet on concrete. Ceilings include: GWB "hard-lid", mechanically fastened 1'x1' ACT on GWB "hard-lid" above SACT. Windows are metal framed and operable. A natural gas boiler located in a mechanical room provides hot water to these two blocks. A central HVAC system provides forced air heating and air conditioning. Block D was originally constructed in 1958 and renovated in 1972 and is a one-story structure encompassing the library and classrooms. Exterior walls are made of BMU on a concrete foundation. The roof is slightly sloped on wood decking. Interior wall finishes include: BMU, GWB, and plaster. Other interior finishes include: vinyl CB throughout. Flooring includes: 12"x12" VCT, 9"x9" VAT, carpet on 9"x9" VAT, carpet on 12"x12" VCT, and carpet on concrete. Ceilings include: GWB "hard-lid", mechanically fastened and glued- on 1'x1' ACT on GWB "hard-lid" above SACT. Windows are operable metal framed windows. A natural gas boiler located in a mechanical room provides hot water to this block. A central HVAC system provides forced air heating and air conditioning. Block E, F, J and K were originally constructed in 1962 and renovated in 1972, 1975 and 2001. The building is a one-story structure housing the theatre and class rooms. Exterior walls are made of BMU and CMU on a concrete foundation. The roof is sloped with 3-tab composite shingles on wood decking. Interior wall finishes include: BMU, GWB, and plaster. Other interior finishes include: vinyl CB throughout. Flooring includes: 12"x12" VCT, 9"x9" VAT, carpet on 9"x9" VAT, carpet on 12"x12" VCT, and carpet on concrete. Ceilings include: GWB "hard-lid", mechanically fastened and glued-on 1'x1' ACT on GWB "hard-lid" above SACT. Lighting is provided by fluorescent fixtures along with operable metal framed windows. A natural gas boiler located in a mechanical room provides hot water to these ehsi.) IS EHS-International,Inc. • • , Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 blocks and Blocks G and H. A central HVAC system provides forced air heating and air conditioning. Block G was originally constructed in 1972 and is a one-story structure housing classrooms. Exterior walls are made of BMU on a concrete foundation. The roof is sloped with 3-tab composite shingles on wood decking. Interior wall finishes include: GWB, and plaster walls. Other interior finishes include: vinyl CB throughout. Flooring includes: 12"x12" VCT, 9"x9" VAT, carpet on 9"x9" VAT, carpet on 12"x12"VCT, and carpet on concrete. Ceilings include: GWB and plaster "hard-lid", mechanically fastened and glued-on 1'x1' ACT on GWB "hard- lid" above SACT. Windows are operable metal framed. A natural gas boiler located in a mechanical room located in block F provides hot water to this block. A central HVAC system provides forced air heating and air conditioning. Block H was originally constructed in 1985 and is a one-story structure housing classrooms. Exterior walls are made of BMU on a concrete foundation. The roof is sloped with 3-tab composite shingles on wood decking. Interior wall finishes include: GWB, and plaster walls. Other interior finishes include: vinyl CB throughout. Flooring includes: 12"x12" VCT, 9"x9" VAT, carpet on 9"x9" VAT, carpet on 12"x12"VCT, and carpet on concrete. Ceilings include: GWB and plaster "hard-lid", mechanically fastened and glued-on 1'x1' ACT on GWB "hard- lid" above SACT. Windows are operable metal framed. A natural gas boiler located in a mechanical room located in block F provides hot water to this block. A central HVAC system provides forced air heating and air conditioning. Portable 1 is a wood-framed, single classroom portable. The roof is flat and exterior walls are made of wood siding. Interior finishes include: cloth covered GWB walls, vinyl CB throughout, and 12"x12" VCT on wood. Lighting is provided by fluorescent light fixtures and metal framed operable windows. Heat is provided by an electric furnace. Portable 2 is a wood-framed, 2 classroom portable. The roof is sloped with 3-tab composite shingles and exterior walls are made of wood siding. Interior finishes include: cloth covered GWB walls, vinyl CB throughout, and carpet on wood. Lighting is provided by fluorescent light fixtures and metal framed operable windows. Heat is provided by an electric furnace. The Community Pool is a single-story brick structure, constructed in 1971. The roof is sloped with 3-tab composite shingles on wood decking. Interior finishes include: ceramic floor tiles, carpet, VAT and VCT on concrete and bare concrete. Interior walls are made of GWB and some are covered with ceramic wall tiles and fibrous panels. Lighting is provided by fluorescent light fixtures. Heating for the building and the pool is provided by a natural gas boiler located in the mechanical room. 2.3 SAMPLING METHODOLOGY 2.3.1 Asbestos-Containing Materials The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in Appendix C. The number of bulk samples collected and their locations are based on the AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a, ehS/i►, EHS-International.Inc. 16 Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 October 1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials. EHSI collected samples and obtained analytical data for suspect ACM identified in the facility. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. "Chain-of-Custody" tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Bellevue, Washington. SAT participates in the NVLAP. Only materials containing more than 1% total asbestos were classified as "asbestos-containing" based on USEPA, state, and local regulations. Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples were taken from the same location and they were sent to separate laboratories. QA samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP laboratory. Copies of both laboratories' NVLAP certifications are included in Appendix D. 2.3.2 Lead-Containing Paint/Lead-Containing Materials EHSI used a Niton Model XLp x-ray fluorescence (XRF) Spectrum Analyzer to measure lead content on interior and exterior paint coatings and other suspect LCM. Measurements were representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is provided in Appendix B. Bulk quality assurance samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory for Atomic Absorption Spectroscopy (USEPA Method-7000B) by the American Industrial Hygiene Association (AIHA) under the Environmental Lead Laboratory Accreditation Program (ELLAP). Copies of laboratory reports and field data forms for lead are in Appendix B. 2.3.3 Arsenic-Containing Materials EHSI collected samples and obtained analytical data for CMU and BMU mortar from the interior and exterior of the facility. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. "Chain-of- Custody" tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. A summary of Arsenic laboratory results is provided in Table 4. Samples were sent to NVL, an accredited laboratory for Inductively Coupled Plasma Spectroscopy (USEPA Method-6010) by the Washington State Department of Ecology. Copies of laboratory reports and field data forms for Arsenic are in Appendix B. 2.4 SAMPLING RESULTS 2.4.1 Asbestos-Containing Materials Eight hundred three (803) bulk samples of suspect ACM were collected as part of the survey. Forty (40) of those samples were split for quality assurance analyses. Limited destructive inspection was conducted to identify hidden and/or concealed materials. Copies ehsi EHS-International,Inc. 17 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 of the asbestos analytical laboratory results are included in Appendix A. Asbestos, lead and arsenic sample location drawings are provided in Appendix E. Asbestos sampling information including: sample number, material description, sample location, and analytical results are summarized in Table 1. The ACM and assumed ACM identified during this survey, including the quantity and location, is summarized in Table 2. Suspect materials not sampled were assumed to be ACM. TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS BLOCK A Layer 1: 4" Beige/gray L1: ND N/A Al - Auxiliary Gym cove base 10527-A-01 Layer 2: Tan mastic L2: ND N/A - South Wall Layer 3: White/beige L3: ND N/A paint Layer 1: Gray seam L1: ND N/A Al - Auxiliary Gym caulking w/paint on 10527-A-02 - South Wall concrete wall Layer 2: Yellow foam L2: ND N/A insulation Al - Auxiliary Gym Layer 1: JC w/ paint L1: ND N/A 10527-A-03 - Southwest (corner) Corner Layer 2: GWB w/ paper L2: ND N/A Al - Auxiliary Gym Layer 1: JC w/ paint (mid L1: ND N/A 10527-A-04 - Southwest wall) Corner Layer 2: GWB w/ paper L2: ND N/A Al Auxiliary Gym Layer 1: JC w/ paint (mid Li: ND N/A 10527 A 05wall) - Southeast Corner Layer 2: GWB w/ paper L2: ND N/A Al - Auxiliary Layer 1: l'xl' White ACT L1: ND N/A 10527-A-06 w/paint Gym Corridor A35 Layer 2: Brown mastic L2: ND N/A 10527-A-07 Al - Auxiliary Gym Layer 1: JC L1: ND N/A Corridor A35 Layer 2: GWB, at seam L2: ND N/A 10527-A-08 Al Auxiliary Gym Tan pipe dope ND N/A Corridor A35 Layer 1: 12"x12" Off- L1: ND N/A Al Auxiliary Gym White VCT w/ brown and 10527-A-09 Corridor A35 white streaks Layer 2: Yellow mastic L2: ND N/A Layer 3: Concrete L3: ND N/A Layer 1: Skim coat w/ L1: ND N/A 10527-A-10 A2 - Weight Room paint South Wall Layer 2: GWB w/ paper L2: ND N/A (corner) ehsi•, 18 EHS-International,Inc. • • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Skim coat w/ L1: ND N/A 10527-A-11 A2 - Weight Room paint South Wall Layer 2: GWB w/ paper L2: ND N/A (mid wall) Layer 1: Skim coat w/ L1: ND N/A 10527-A-12 A2 - Weight Room paint South Wall Layer 2: GWB w/ paper L2: ND N/A (mid wall) Layer 1: 4" Black cove L1: ND N/A A2 - Weight Room base 10527-A-13 Northeast Corner Layer 2: Cream colored L2: ND N/A mastic Layer 3: White paint L3: ND N/A Layer 1: Blue carpet L1: ND N/A 10527-A-14 A2 - Weight Room Layer 2: Gray carpet foam L2: ND N/A Layer 3: Yellow mastic L3: ND N/A Layer 1: 2'x4' SACT w/ L1: ND N/A 10527-A-15 A2 - Corridor A46 foil and mastic Layer 2: Gray 2'x4' SACT L2: ND N/A Layer 1: 6"X6" L1: ND N/A Orange/brown ceramic 10527-A-16 A2 - A50 Lockers cove base tiles Layer 2: Gray grout L2: ND N/A Layer 3: Gray mortar L3: ND N/A Layer 1: 1" & 2" L1: ND N/A Brown/orange ceramic 10527-A-17 A2 - A50 Lockers floor tile Layer 2: Gray grout L2: ND N/A Layer 3: Black/gray L3: ND N/A mortar 10527-A-18 A2 - A50 Lockers Black speaker coating ND N/A w/white paint 10527-A- Layer 1: Beige paint L1: ND N/A 19QA A2 - A50 Lockers Layer 2: White skim coat L2: ND N/A Layer 3: Plaster L3: ND N/A Layer 1: Beige paint L1: ND N/A 10527-A-20 A2 - A50 Storage Layer 2: White skim coat L2: ND N/A Layer 3: Plaster L3: ND N/A Layer 1: White Paint L1: ND N/A 10527-A-21 A2 - A55 Shower Layer 2: Silver Paint L2: ND N/A Layer 3: Plaster L3: ND N/A Layer 1: White Paint L1: ND N/A 10527-A-22 A2 - A55 Shower Layer 2: Silver Paint L2: ND N/A Layer 3: Plaster L3: ND N/A ehsi 4► 19 EHS-International,Inc. • i Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: White Paint Li: ND N/A 10527-A-23 A2 - A56 Entry Layer 2: White skim coat L2: ND N/A Layer 3: Plaster L3: ND N/A Layer 1: White Paint L1: ND N/A 10527-A-24 A2 - A62 Shower Layer 2: Silver Paint L2: ND N/A Layer 3: Plaster L3: ND N/A Layer 1: Beige Paint L1: ND N/A 10527-A-25 A2 - A60 Lockers Layer 2: White skim coat L2: ND N/A Layer 3: Plaster L3: ND N/A Layer 1: Beige Paint L1: ND N/A 10527-A-26 A2 - A60 Lockers Layer 2: White skim coat L2: ND N/A Layer 3: Plaster L3: ND N/A L1: 20% Chrysotile Layer 1: Black asphaltic built up roofing A2 -Interstitial Layer 2: Black asphaltic L2: 21% Chrysotile 10527-A-27 Space between built up roofing 1St and 2"d Floor Layer 3: Brown fibrous insulation L3: ND N/A Layer 4: Black asphaltic vapor barrier L4: 21% Chrysotile L1: 20% Chrysotile Layer 1: Black asphaltic built up roofing L2: ND N/A Layer 2: Black asphaltic built up roofing L3: 23% Chrysotile Layer 3: Black asphaltic built up roofing L4: 20% Chrysotile Layer 4: Black asphaltic vapor barrier A2 -Interstitial L5: 22% Chrysotile 10527-A-28 Space between Layer 5: Black asphaltic 1St and 2nd Floor built up roofing Layer 6: Black asphaltic L6: 22% Chrysotile built up roofing Layer 7: Black asphaltic built up roofing L7: 21% Chrysotile Layer 8: Brown fibrous insulation 3 Layer 9: Black asphaltic L8: ND N/A vapor barrier L9: 20% Chrysotile EHS-International,Inc. 20 i i Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS A2 - Interstitial Gray light weight concrete 10527-A-29 Space between 1stat roof edge ND N/A and 2nd Floor g Layer 1: 4" White ceramic L1: ND N/A 10527-A- wall tiles 30QA A2 - A59 Toilet Layer 2: White grout L2: ND N/A Layer 3: Tan mastic w/ L3: ND N/A paint Layer 1: 1" Gray ceramic L1: ND N/A wall tile Layer 2: Gray grout L2: ND N/A 10527-A-31 A2 - A59 Toilet Layer 3: Gray mortar L3: ND N/A Layer 4: Yellow mastic L4: ND N/A Layer 5: Trace amount of L5: ND N/A concrete Layer 1: JC w/ paint L1: ND N/A 10527-A-32 A2 - A50 Lockers Layer 2: GWB w/ paper, L2: ND N/A at edge of soffit Layer 1: JC w./ paint L1: ND N/A 10527-A-33 A2 - A60 Lockers Layer 2: GWB w/ paper, L2: ND N/A at middle of soffit Layer 1: JC w./ paint Li: ND N/A 10527-A-34 A2 - A60 Lockers Layer 2: GWB w/ paper, L2: ND N/A at middle of ceiling Layer 1: JC w./ paint L1: ND N/A 10527-A-35 A2 - A50 Lockers Layer 2: GWB w/ paper, L2: ND N/A at middle of ceiling Layer 1: JC w./ paint Li: ND N/A 10527-A-36 A2 - A50 Lockers Layer 2: GWB w/ paper, L2: ND N/A at ceiling edge 2'x4' White SACT w/ pin 10527-A-37 A2 - A57 Office hole and worm track ND N/A pattern w/paint 10527-A-38 A2 - A50 Lockers White sink undercoat ND N/A Layer 1: Beige carpet L1: ND N/A 10527-A-39 A2 - A50 Entry backing Layer 2: Yellow mastic L2: ND N/A Layer 3: Tan/gray mastic L3: ND N/A 10527-A-40 A2 - A50 Entry White door frame caulking ND N/A w/paint Layer 1: 12"x12" Off- L1: ND N/A 10527-A-41 A2 - A52 Storage white VCT w/ brown, yellow and white specks Layer 2: Black mastic L2: ND N/A ehsi EHS-International,Inc. 21 i • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Yellow VCT L1: ND N/A mastic 10527-A- A2 - A66 Layer 2: Gray leveling L2: ND N/A 42QAx Corridor compound Layer 3: Residual black L3: 3% Chrysotile mastic Layer 1: Yellow mastic L1: ND N/A (associated w/ VCT) 10527-A-43 A2 - A71 Corridor Layer 2: White leveling L2: ND N/A compound Layer 3: Black mastic L3: ND N/A Layer 1: 6"x6" Red L1: ND N/A 10527-A-44 A2 - A70 Janitor ceramic floor tile Layer 2: Gray grout L2: ND N/A Layer 3: Gray mortar L3: ND N/A 10527-A-45 A2 - A70 Janitor Black asphaltic sealant ND N/A around floor drain Layer 1: White paint L1: ND N/A A2 A72 Men's Layer 2: 2'x4' textured L2: ND N/A 10527-A-46 ACT Room Layer 3: 1'x1' White ACT L3: ND N/A Layer 4: Brown glue dot L4: ND N/A Layer 1: Brown stair L1: 2% Chrysotile tread 10527-A-47 A2 - Stair 1 Layer 2: Green mastic L2: ND N/A Layer 3: Brown/yellow L3: ND N/A mastic with JC Layer 1: Brown SVF L1: 2% Chrysotile 10527-A-48 A2 - Stair 1 Layer 2: Yellow mastic on L2: ND N/A wood Layer 1: 8" Brown vinyl L1: 2% Chrysotile cove base/stair 10527-A-49 A2 - Stair 1 stringer Layer 2: Brown mastic on L2: ND N/A wood Layer 1: 4" Brown cove L1: ND N/A base 10527-A-50 A4 - A4-3 Exercise Layer 2: Cream colored L2: ND N/A mastic Layer 3: Tan/brown L3: ND N/A mastic Layer 1: 4"Tan/beige L1: ND N/A 10527-A-51 A4 - A4-3 Exercise cove base Layer 2: Cream colored L2: ND N/A mastic ehsi.4.0 22 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Dark brown/gray L1: ND N/A 10527-A-52 A4 - A4-3 Exercise glue dot Layer 2: Tan wood debris L2: ND N/A Layer 1: White skim coat L1: ND N/A 10527-A-53 A4 - A4-3 Exercise w/ paint Layer 2: White GWB w/ L2: ND N/A paper (mid wall) Layer 1: White skim coat L1: ND N/A 10527-A-54 A4 - A4-3 Exercise w/ paint Layer 2: White GWB w/ L2: ND N/A paper (mid wall) Layer 1: White skim coat L1: ND N/A 10527-A-55 A4 - A4-3 Exercise w/ paint Layer 2: White GWB w/ L2: ND N/A paper (mid wall) Layer 1: White skim coat L1: ND N/A 10527-A-56 A4 - A4-3 Exercise w/ paint Layer 2: White GWB w/ L2: ND N/A paper (mid wall) Layer 1: White skim coat L1: ND N/A 10527-A-57 A4 - A4-3 Exercise w/ paint Layer 2: White GWB w/ L2: ND N/A paper (mid wall) 10527-A-58 A4 - A4-2 Exercise Black flex duct w/ black ND N/A caulking w/paint 10527-A-59 A4 - A4-2 Exercise Tan pipe dope ND N/A Layer 1: 1'x1' White ACT L1: ND N/A 10527-A-60 A4 - A4-2 Exercise w/ pin hole pattern Layer 2: Brown mastic L2: ND N/A 10527-A-61 Al-A2 Gymnasium TectumT" panel w/yellow ND N/A mastic Layer 1: White skim coat L1: ND N/A 10527-A-62 Al-A2 Gymnasium w/ paint Layer 2: GWB w/ paper L2: ND N/A (mid wall) Layer 1: White skim coat L1: ND N/A 10527-A-63 Al-A2 Gymnasium w/ paint Layer 2: GWB w/ paper L2: ND N/A (corner) Al -Girls Locker Layer 1: White skim coat L1: 0.5% N/A 10527-A-64`1 Room A15 Office Layer 2: Pink GWB w/ L2: ND N/A paper (ceiling edge) ehsi423 EHS-International,Inc. . • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: White skim coat L1: 0.75% N/A 10527-A-65*' Al -Girls Locker w/ paint Room A15 Office Layer 2: Pink GWB w/ L2: ND N/A paper (mid ceiling) Layer 1: White skim coat L1: ND N/A Al - Girls Locker w/ paint and powdery 10527-A-66 Room A10 Lockers material Layer 2: GWB w/ paper L2: ND N/A (ceiling edge) Layer 1: White skim coat L1: ND N/A 10527-A-67 Al - Girls Locker w/ paint Room A10 Lockers Layer 2: GWB w/ paper L2: ND N/A (mid ceiling) Layer 1: White skim coat L1: ND N/A 10527-A-68 Al - Girls Locker w/ paint Room A24 Lockers Layer 2: GWB w/ paper L2: ND N/A (mid soffit) 10527-A-69 Al - Girls Locker Layer 1; White paint L1: ND N/A Room Al2 Shower Layer 2: Plaster (ceiling) L2: ND N/A 10527-A-70 Al - Girls Locker Layer 1; White paint L1: ND N/A Room Al2 Shower Layer 2: Plaster (ceiling) L2: ND N/A Al - Girls Locker Layer 1: Gray paint L1: ND N/A 10527-A-71 Room A22 Shower Layer 2: Gray plaster L2: ND N/A (ceiling) Layer 1: 1"xl" Brown L1: ND N/A Al Girls Locker ceramic floor tiles 10527-A-72 Layer 2: Gray grout L2: ND N/A Room A6 Storage Layer 3: Beige mastic L3: ND N/A Layer 4: Gray mortar L4: ND N/A 10527-A-73 Al Girls Locker Gray duct seam sealant ND N/A Room A6 Storage 10527-A-74 Al - Girls Locker Black window glazing ND N/A Room A10 Lockers putty w/paint and mastic Al Girls Locker Layer 1: White window L1: ND N/A 10527-A-75 Room A10 Lockers frame caulking w/ paint Layer 2: Concrete debris L2: ND N/A 10527-A-76 Al - Girls Locker Residual black mastic on ND N/A Room A6 Storage concrete Layer 1: 4"x4" White L1: ND N/A 10527-A-77 Al- Girls Locker ceramic wall tile Room A25 Toilet Layer 2: White grout L2: ND N/A Layer 3: Tan mastic L3: ND N/A ehsi 24 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: 1"xl" Gray L1: ND N/A ceramic L2: ND N/A Al - Girls Locker Layer 2: Gray grout L3: ND N/A 10527-A-78 Room A17 Dress Layer 3: Yellow mastic L4: ND N/A Layer 4: Dark gray mortar Layer 5: Gray light weight L5: ND N/A concrete A2 - Mechanical Beige duct edge 10527-A-79 Area above A38 caulking/sealant (by flex ND N/A Training ducts) A2 Mechanical Beige duct seam sealant 10527-A-80 Area above A38 ND N/A (at duct flanges) Training A2 Mechanical Gray duct seam sealant 10527-A-81 Area above A38 ND N/A (at duct flanges) Training A2 Mechanical Yellow/tan duct seam 10527-A-82 Area above A38 ND N/A sealant Training A2 - Mechanical Layer 1: Black material L1: ND N/A 10527-A-83 Area above A38 Layer 2: Concrete debris L2: ND N/A Training Layer 3: Wood debris L3: ND N/A 10527-A-84 A2 - A38 Training Off-white sink undercoat ND N/A A2 - Mechanical Layer 1: White skim coat L1: ND N/A 10527-A-85 Area above A38 w/ paint Training Layer 2: Plaster wall L2: ND N/A A2 - Mechanical Layer 1: White skim coat L1: ND N/A 10527-A-86 Area above A38 w/ paint Training Layer 2: Plaster wall L2: ND N/A A2 - Mechanical Layer 1: White skim coat L1: ND N/A 10527-A-87 Area above A38 w/ paint Training Layer 2: Plaster wall L2: ND N/A Layer 1: Yellow carpet Ll: ND N/A mastic 10527-A- A2 - A75 Layer 2: 9"x9" Burnt L2: 4% Chrysotile 88QAx Marketing orange VAT Layer 3: Black mastic on L3: ND N/A concrete ehsi 4 25 EHS-International,Inc. • . . Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Yellow carpet L1: ND N/A mastic Layer 2: Gray leveling L2: ND N/A 10527-A-89 A2 - A76 compound Marketing Layer 3: 9"x9" Burnt L3: 3% Chrysotile orange VAT Layer 4: Black mastic on L4: ND N/A concrete 10527-A-90 A2 - A4-4 Green/dark gray duct ND N/A Mechanical seam sealant 10527-A-91 A2 - A4-4 Gray louver frame ND N/A Mechanical caulking 10527-A-92 A2 - A4-4 White conduit penetration ND N/A Mechanical sealant 10527-A- Al - A3 Student Layer 1: l'xl' White ACT L1: ND N/A 93QA Store Layer 2: Brown glue dot L2: ND N/A Layer 1: 12"x12" Light L1:ND N/A gray VCT 10527-A-94 Al - A2 Commons Layer 2: Yellow mastic L2: ND N/A Layer 3: Black mastic on L3: ND N/A concrete Layer 1: 12"x12" Blue L1: ND N/A VCT 10527-A-95 A2 - A74 Corridor Layer 2: Yellow mastic L2: ND N/A Layer 3: Black mastic on L3: ND N/A concrete Layer 1: Blue carpet L1: ND N/A Layer 2: Yellow mastic L2: ND N/A 10527-A-96 Al - A5 ASB Layer 3: Gray leveling L3: ND N/A compound Layer 4: Residual black L4: 3% Chrysotile mastic on concrete A2 - Basement 10527-A-97 Mechanical Room Tan pipe dope ND N/A 01 A2 - Basement 10527-A-98 Mechanical Room Red flange gasket ND N/A 01 A2 - Basement Black penetration sealant 10527-A-99 Mechanical Room on boiler flue ND N/A 01 A2 - Basement White penetration sealant 10527-A-100 Mechanical Room on boiler flue ND N/A 01 ehsi��► EHS-International,Inc. 26 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS A2 - Basement 10527-A- Black fibrous vapor barrier 101QA Mechanical Room (in ceiling penetration) ND N/A A2 - Basement Black asphaltic tar (in 10527-A-102 Mechanical Room ceiling penetration) ND N/A 01 A2 - Basement White coating on ceiling 10527-A-103 Mechanical Room panels ND N/A 01 A2 - Basement Layer 1: Brown cork L1: ND N/A 10527-A-104 Mechanical Room ceiling panel 01 Layer 2: White coating L2: ND N/A Layer 3: Concrete debris L3: ND N/A A2 - Basement Layer 1: JC w/ paint L1: ND N/A 10527-A-105 Mechanical Room Layer 2: GWB w/ paper L2: ND N/A 01 (corner) A2 - Basement Layer 1: JC w/ paint L1: ND N/A 10527-A-106 Mechanical Room Layer 2: GWB w/ paper L2: ND N/A 01 (mid wall) A2 - Basement Layer 1: JC w/ paint L1: ND N/A 10527-A-107 Mechanical Room Layer 2: GWB w/ paper L2: ND N/A 01 Generator (mid wall) Room A2 - Basement Layer 1: Black seam L1: ND N/A 10527-A-108 Mechanical Room sealant (on nail 01 Generator penetrations) Room Layer 2: Sand debris L2: ND N/A A2 - Basement Black/gray seam sealant 10527-A-109 Mechanical (on generator exhaust ND N/A Exterior Enclosure unit) A2 Basement Black seam sealant(on 10527-A-110 Mechanical generator exhaust unit) ND N/A Exterior Enclosure Layer 1: Light pink L1: ND N/A 10527-A-111 Al - Main fireproofing w/ trace Gymnasium mastic Layer 2: Wood debris L2: ND N/A 10527-A-112 Al - Main Light pink fireproofing w/ ND N/A Gymnasium mastic Al - Main Layer 1: Light pink Li: ND N/A 10527-A-113 Gymnasium fireproofing w/ mastic Layer 2: Wood debris L2: ND N/A Al - Main Layer 1: Light pink Li: ND N/A 10527-A-114 Gymnasium fireproofing w/ mastic Layer 2: Wood debris L2: ND N/A ehs ., EHS-International,Inc. 27 . • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Light pink L1: ND N/A Al - A34 Aux fireproofing 10527-A-115 Layer 2: JC w/ paper L2: ND N/A Gymnasium Layer 3: GWB w/ paper L3: ND N/A (at seam) Layer 1: Light pink L1: ND N/A 10527-A-116 Al - A34 Aux fireproofing Gymnasium Layer 2: GWB w/ paper L2: ND N/A (ceiling) Layer 1: Light pink L1: ND N/A 10527-A-117 Al - A34 Aux fireproofing Gymnasium Layer 2: GWB w/ paper L2: ND N/A (ceiling) Layer 1: Brown vapor L1: ND N/A barrier w/ black asphaltic backing 10527-A- Al - Main Layer 2: Hardwood floor L2: ND N/A 118 Gymnasium sleepers Layer 3: Black asphaltic L3:21% Chrysotile vapor barrier tarred to concrete Layer 1: Hard wood L1: ND N/A flooring Layer 2: Brown vapor L2: ND N/A barrier w/ black asphaltic backing 10527-A- Al - Main Layer 3: Hardwood floor L3: ND N/A 119 Gymnasium sleepers Layer 4: Multi-layered L4: 19% Chrysotile black asphaltic vapor barrier Layer 5: Black asphaltic L5: ND N/A tar on concrete Layer 1: Hardwood L1: ND N/A flooring Layer 2: Brown vapor L2: ND N/A barrier w/ black asphaltic 10527-A- Al - Main backing 120 Gymnasium Layer 3: Hardwood floor L3: ND N/A sleepers Layer 4: Black asphaltic L4: 20% Chrysotile vapor barrier on concrete 10527-A-121 A2 - A34 Aux Brown hard wood flooring ND N/A Gymnasium w/ concrete debris ehs14 ENS-International,Inc. 28 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS BLOCK B 10527-B-01 2001 Era Cafeteria Light gray door/window ND N/A frame caulking Layer 1: 4"Tan/gray cove L1: ND N/A 10527-B-02 2001 Era Cafeteria base Layer 2: Cream colored L2: ND N/A mastic 10527-B-03 2001 Era Cafeteria White plaster w/ paint on ND N/A wall 10527-B-04 2001 Era Cafeteria White plaster w/ paint on ND N/A wall 10527-B-05 2001 Era Cafeteria White plaster w/ paint on ND N/A wall Layer 1: 12"x12" Light L1: ND N/A gray VCT 10527-B-06 2001 Era Cafeteria Layer 2: Yellow mastic L2: ND N/A Layer 3: Gray leveling L3: ND N/A compound on concrete Layer 1: Tan/ white L1: ND N/A 10527-B-07 2001 Era Cafeteria fibrous wall panel w/ paint Layer 2: Black mastic on L2: ND N/A concrete Layer 1: 12"x12" Blue L1: ND N/A 10527-B- VCT 08QAX B1/B2 Cafeteria Layer 2: Yellow mastic L2: ND N/A Layer 3: Residual black L3: 2% Chrysotile mastic on concrete 10527-B-09 B2 Cafeteria Gray door frame caulking ND N/A w/ paint and JC Layer 1: White skim coat L1: ND N/A 10527-B-10 B2 Cafeteria Wall w/ paint Layer 2: GWB w/ paper L2: ND N/A Layer 1: White skim coat L1: ND N/A 10527-B-11 B2 Cafeteria Wall w/ paint Layer 2: GWB w/ paper L2: ND N/A Cafeteria B6 Entry Layer 1: White skim coat L1: ND N/A 10527-B-12 Wall w/ paint Layer 2: GWB w/ paper L2: ND N/A Layer 1: White skim coat L1: ND N/A 10527-B-13 B2 Cafeteria Wall w/ paint Layer 2: GWB w/ paper L2: ND N/A Layer 1: White skim coat L1: ND N/A 10527-B-14 B3 Cafeteria Wall w/ paint Layer 2: GWB w/ paper L2: ND N/A e si.► EHS-International,Inc. 29 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS 10527-B-15 B1 Cafeteria 2'x4' SACT w/ pin hole ND N/A and worm track pattern Layer 1: 1'x1' White ACT L1: ND N/A 10527-B-16 B1 Cafeteria w/ large hole pattern Layer 2: Brown glue dot L2: ND N/A Layer 1: 6" Red ceramic L1: ND N/A 10527-B-17 B9 Kitchen quarry tile Layer 2: Gray grout and mortar L2: ND N/A 10527-B-18 B9 Kitchen Black caulking on red ND N/A quarry tile cove base Layer 1: 1'x1' White ACT L1: ND N/A w/ small hole pattern 10527-B-19 B11 Servery Layer 2: Dark brown glue L2: ND N/A dot Layer 3: GWB paper L3: ND N/A Layer 1: 2'x4' SACT w/ L1: ND N/A 10527-B-20 B12 Fast Food paint Layer 2: Plastic cover L2: ND N/A Layer 1: Black window L1: ND N/A 10527-B-21 B9 Kitchen frame caulking Layer 2: Off-white window L2: ND N/A frame caulking Layer 1: Gray caulking L1: ND N/A 10527-B-22 B9 Kitchen Layer 2: Silver caulking, L2: ND N/A around sinks and wash stations Layer 1: 4" Cream colored L1: ND N/A cove base 10527-B-23 B11 Servery Layer 2: Cream colored L2: ND N/A mastic Layer 3: JC w/ paint L3: ND N/A Layer 4: GWB, at edge L4; ND N/A 10527-B- B5 Corridor Gray window frame 3% Chrysotile 24QAx caulking Layer 1: 4"Tan/gray cove L1: ND N/A base Layer 2: Cream colored L2: ND N/A 10527-B-25 B5 Corridor mastic Layer 3: Residual L3: 3% Chrysotile brown mastic on concrete ehsi 30 EHS-International,Inc. , 0 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: White skim coat L1: ND N/A 10527-B-26 B1/B2 Cafeteria w/ paint Layer 2: GWB (ceiling L2: ND N/A edge) Layer 1: White skim coat L1: ND N/A 10527-B-27 B1/B2 Cafeteria w/ paint Layer 2: GWB (mid L2: ND N/A ceiling) Layer 1: White skim coat L1: ND N/A 10527-B-28 B1/B2 Cafeteria w/ paint Layer 2: GWB (mid L2: ND N/A ceiling) 10527-B-29 B2 Cafeteria Yellow/tan pipe dope ND N/A 10527-B-30 B2 Cafeteria White paint covering on ND N/A 2'x4' GWB SACT w/ paper 10527-B-31 B5 Corridor Remnant ACT w/ brown ND N/A mastic on wood decking Interior gray window 10527-B-32 B2 Cafeteria glazing putty 3% Chrysotile (clearstory) 10527-B-33 B4A Riser Room Black pipe flange gasket ND N/A BLOCK C Layer 1: Gray window L1: ND N/A Original Building frame caulking 10527-C-01 C-117 Layer 2: Black window L2: ND N/A frame caulking w/ paint and mastic Original Building Layerframe 1:caulkin Blacgwindow L1: ND N/A 10527-C-02 C-117 w/paint Layer 2: Wood debris L2: ND N/A Layer 1: 4" Black cove L1: ND N/A 10527-C-03 Original Building base C-117 Layer 2: Cream colored L2: ND N/A mastic 10527-C-04 Original Building Black sink undercoat 3% Chrysotile C-117 Layer 1: 12"x12" Off- L1: ND N/A white VCT w/ brown, 10527-C-05 Original Building yellow and white streaks C-117 Layer 2: Yellow mastic L2: ND N/A Layer 3: Gray leveling L3: ND N/A compound on concrete ehsi�.� ;, EHS-International,Inc. • S , Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Gray carpet L1: ND N/A 10527-C-06 Original Building backing w/ clear mastic C-117 Layer 2: Gray leveling L2: ND N/A compound on concrete Original Building 2'x4' SACT w/ pin hole 10527-C-07 C-117 and worm track pattern ND N/A w/paint Layer 1: 1'x1' White SACT Li: ND N/A Original Building w/ random pin hole 10527-C-08 C-117 pattern Layer 2: Brown glue dot L2: ND N/A w/ GWB paper Original Building Layer 1: White texturing L1: ND N/A 10527-C-09 C-117 w/ paint Layer 2: GWB (mid wall) L2: ND N/A Original Building Layer 1: White texturing L1: ND N/A 10527-C-10 C-117 w/ paint Layer 2: GWB (mid wall) L2: ND N/A Original Building Layer 1: White texturing L1: ND N/A 10527-C-11 C-117 w/ paint Layer 2: GWB (corner) L2: ND N/A 10527-COriginal Building Layer 1: 1'x1' ACT w/ L1: ND N/A 12QA Corridor C-116 large hole pattern Layer 2: Brown glue dot L2: ND N/A Original Building Layer 1: Skim coat Li: ND N/A 10527-C-13 w/paint Corridor C-116 Layer 2: Plaster (ceiling) L2: ND N/A Layer 1: Skim coat L1: ND N/A 10527-C-14 Original Building w/paint Corridor C-116 Layer 2: Plaster (ceiling) L2: ND N/A Layer 3: GWB L3: ND N/A 10527-C-15 Original Building Layer 1: Skim coat L1: ND N/A Corridor C-116 Layer 2: Plaster (ceiling) L2: ND N/A Layer 1: White coating on L1: ND N/A 10527-C-16 Original Building SACT w/paint Corridor C-116 Layer 2: Silver foil L2: ND N/A Layer 3: 2'x4' SACT L3: ND N/A Layer 1: White skim coat L1: ND N/A 10527-C-17 Original Building w/ paint Corridor C-116 Layer 2:GWB (mid ceiling) L2: ND N/A Layer 1: White skim coat L1: ND N/A 10527-C-18 Original Building w/ paint Corridor C-116 Layer 2:GWB (mid ceiling) L2: ND N/A ehsi EHS-International,Inc. 32 • w Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: White skim coat L1: ND N/A 10527-C-19 Original Building w/ paint Corridor C-116 Layer 2:GWB, ceiling edge L2: ND N/A Layer 1: 4"Tan/gray cove L1: ND N/A base 10527-C-20 Original Building Layer 2: Cream colored L2: ND N/A Corridor C-116 mastic Layer 3: JC L3: ND N/A Layer 4: GWB w/ paper L4: ND N/A 10527-C-21 Original Building Black window glazing ND N/A Corridor C-116 putty w/mastic Layer 1: 12"x12" Light L1: ND N/A Gray VCT w/ gray and Original Building white streaks 10527-C-22 Layer 2: Yellow mastic L2: ND N/A Corridor C-116 Layer 3: Gray leveling L3: ND N/A compound Layer 4: Concrete debris L4: ND N/A Layer 1: 12"x12" Blue L1: ND N/A VCT Original Building Layer 2: Yellow mastic L2: 3% Chrysotile 10527-C-23 Corridor C-116 on gray leveling compound on residual black mastic on concrete Layer 1: Yellow/tan L1: ND N/A mastic (associated w/ 12"x12" light gray VCT) L2: ND N/A 10527-C- Original Building Layer 2: Gray leveling 24QAx Corridor C-116 Compound L3: 9% Chrysotile Layer 3: Black VAT L4: 3% Chrysotile Layer 4: Black mastic on concrete Layer 1: Beige/Green L1: ND N/A mastic 10527-C-25 Original Building Layer 2: Yellow mastic L2: ND N/A Corridor C-116 Layer 3: Gray leveling L3: ND N/A compound Layer 4: Concrete debris L4: ND N/a ehS/1.4 33 ENS-International,Inc. Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Yellow mastic L1: ND N/A (associated w/ 12"x12" off-white VCT (w/ brown, Original Building yellow, and white 10527-C-26 Passage C-115 streaks)) L2: ND N/A Layer 2: Gray leveling compound 3% Chrysotile Layer 3: Residual black mastic on concrete Layer 1: 1"x1" Light gray L1: ND N/A ceramic floor tile 10527-C-27 Original Building Layer 2: Beige mastic L2: ND N/A Women C-112 L3: ND N/A Layer 3: Light gray grout L4: ND N/A Layer 4: Dark gray mortar Layer 1: 4"x4" White L1: ND N/A Original Building ceramic wall tile 10527-C-28 Women C-112 Layer 2: Beige mastic L2: ND N/A Layer 3: White grout L3: ND N/A Layer 4: JC w/ paint L4: ND N/A Layer 1: Beige/yellow L1: ND N/A carpet mastic Layer 2: 12"x12" Off- L2: ND N/A 10527-C-29 Original Building white VCT Copy C-111 Layer 3: Gray leveling L3: 3% Chrysotile compound on residual black mastic on concrete Layer 1: Light Gray SVF L1: ND N/A (w/ broken rock pattern) L2: ND N/A Layer 2: Brown paper 10527-C-30 Original Building backing w/ mastic L3: ND N/A Janitor C-110 Layer 3: Gray/Brown leveling compound L4: 3% Chrysotile Layer 4: Residual black mastic on concrete Original Building Layer 1: Silver duct paint L1: ND N/A 10527-C-31 C-107 Layer 2: Green/gray duct L2: ND N/A seam sealant Layer 1: White duct seam L1: ND N/A 10527-C-32 Original Building sealant C-107 Layer 2: Green/gray duct L2: ND N/A seam sealant '' s •. 34 ENS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Original Building 10527-C-33 Data Processing C- Black speaker coating ND N/A 109 Original Building Layer 1: 1'x1' ACT w/ L1: ND N/A 10527-C-34 Data Processing small pin hole pattern C-109 Layer 2: Dark brown glue L2: ND N/A dot Layer 1: Blue carpet L1: ND N/A Layer 2: Yellow/brown L2: ND N/A Original Building mastic 10527-C-35 Career C-107 Layer 3: Gray leveling L3: ND N/A compound Layer 4: Residual black 3% Chrysotile mastic on concrete Layer 1: Yellow/tan carpet L1: ND N/A mastic Layer 2: Gray leveling L2: ND N/A 10527-C-36 Original Building compound Office C-105 Layer 3: 9"x9" Black L3: 3% Chrysotile VAT Layer 4: Black mastic L4: 3% Chrysotile on concrete Original Building Layer 1: Skim coat w/ Li: ND N/A 10527-C-37 Career C-107 paint Layer 2: Plaster (ceiling) Li: ND N/A Original Building Layer 1: Skim coat w/ Li: ND N/A 10527-C-38 Career C-107 paint Layer 2: Plaster (ceiling) L1: ND N/A Original Building Layer 1: Skim coat w/ Li: ND N/A 10527-C-39 Career C-107 paint Layer 2: Plaster (ceiling) Li: ND N/A Original Building Layer 1: Yellow fiberglass L1: ND N/A 10527-C-40 Old Section of ceiling panels Boiler Room Layer 2: Yellow/tan L2: ND N/A mastic Layer 1: Orange SVF (w/ L1: ND N/A yellow and brown streaks) Layer 2: Trace of yellow L2: ND N/A 10527-C- Original Building mastic 41QAX Girls C-135 Layer 3: Gray paper L3: 2% Chrysotile backing Layer 4: Trace of black L4: 3% Chrysotile mastic on concrete ehsi EHS-International,Inc. 35 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Original Building Tan pipe dope w/ fibrous 10527-C-42 Old Section of material and debris ND N/A Boiler Room Original Building Layer 1:1'x1' ACT w/ L1: ND N/A 10527-C-43 Girls C-135 metal decorative cover Layer 2: Brown glue dot L2: ND N/A Layer 1: Blue rubber stair L1: ND N/A tread 10527-C-44 Original Building Layer 2: Brown mastic L2: ND N/A Stair 4 Layer 3: Beige mastic L3: ND N/A Layer 4: Brown wood L4: ND N/A debris Layer 1: 6" Blue rubber L1: ND N/A 10527-C-45 Original Building stringer Stair 4 Layer 2: Yellow mastic L2: ND N/A Layer 3: JC w/ paint L3: ND N/A Original Building Layer 1: Skim coat w/ L1: ND N/A 10527-C-46 Career C-106 paint Layer 2: Plaster (wall) L1: ND N/A Original Building Layer 1: Skim coat w/ L1: ND N/A 10527-C-47 Career C-106 paint Layer 2: Plaster (wall) L1: ND N/A Original Building Layer 1: Skim coat w/ L1: ND N/A 10527-C-48 Career C-106 paint Layer 2: Plaster (wall) L1: ND N/A Layer 1: Skim coat w/ L1: ND N/A 10527-C-49 Original Building paint Corridor C-116 Layer 2: GWB w/ paper L1: ND N/A (corner) Layer 1: Skim coat w/ L1: ND N/A 10527-C-50 Original Building paint Corridor C-116 Layer 2: GWB w/ paper L1: ND N/A (mid wall) Original Building Layer 1: Skim coat w/ L1: ND N/A 10527-C-51 Men's Restroom C- paint 113 Layer 2: GWB w/ paper L1: ND N/A (corner) Original Building Layer 1: Skim coat w/ L1: ND N/A 10527-C-52 Men's Restroom C- paint 113 Layer 2: GWB w/ paper L1: ND N/A (mid wall) 10527-C-53 Original Building Brown GWB w/ paint (mid ND N/A Girls C-135 wall) ehsi 4.0 36 EHS-International,Inc. I • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Original Building Layer 1: White skim coat L1: ND N/A 10527-C-54 w/ paint Office C-106 Layer 2: GWB (mid wall) L2: ND N/A 10527-C-55 Original Building GWB w/ paint and paper ND N/A Conference C-108 (mid wall) Original Building Layer 1: JC w/ paint L1: ND N/A 10527-C-56 Girls C-135 Layer 2: Brown GWB L2: ND N/A (corner) Original Building GWB w/ paint and paper 10527-C-57 Girls C-135 (mid wall) ND N/A Original Building Layer 1: White skim coat Li: ND N/A 10527-C-58 Storage C-109/ w/ paint I.H.S C102 Layer 2: GWB (mid wall) L2: ND N/A Layer 1: Tan/brown L1: ND N/A 10527-C-59 Original Building caulking L2: ND N/A Boiler, West Layer 2: Black flange gaskets (on gas regulator) 10527-C-60 Original Building White coating w/ paint, on ND N/A Boiler, West concrete wall 10527-C-61 Original Building Blue MAG TSI Fitting ND N/A Boiler, West 10527-C-62 Original Building Blue MAG TSI Fitting ND N/A Boiler, West 10527-C-63 Original Building Blue MAG TSI Fitting ND N/A Boiler, West Layer 1: White sealant L1: ND N/A 10527-C-64 Original Building w/paint Boiler, West Layer 2: Yellow fiberglass L2: ND N/A 10527-C-65 Original Building White coating w/ paint on ND N/A Boiler, West concrete walls 10527-C-66 Original Building White coating w/ paint on ND N/A Boiler, West concrete walls Original Building 2'x4' SACT w/ worm track 10527-C-67 2nd Floor E.S.L. C- and pin hole pattern ND N/A 208 Original Building Layer 1: 1'x1' ACT w/ pin L1: ND N/A 10527-C-68 2nd Floor E.S.L. C- hole pattern 208 Layer 2: Brown glue dot L2: ND N/A Layer 3: GWB w/ paper L3: ND N/A Original Building Layer 1: White skim coat L1: ND N/A 10527-C-69 2nd Floor E.S.L. C- w/ paint 208 Layer 2: Plaster L2: ND N/A Layer 3: GWB L3: ND N/A ehsi.. EMS-International.Inc. 37 S ! Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Original Building Layer 1: White skim coat L1: ND N/A 10527-C-70 2nd Floor Corridor w/ paint C-216 Layer 2: Plaster (on GWB) L2: ND N/A Layer 1: White coating on Li: ND N/A Original Building SACT w/paint 10527-C-71 2nd Floor Corridor Layer 2: Foil backing L2: ND N/A C-216 Layer 3: 2'x4' SACT w/ L3: ND N/A pin hole pattern Original Building Layer 1: Hard L1: ND N/A 10527-C-72 2nd Floor Men's orange/brown flooring Restroom C-220 Layer 2: Gray leveling L2: ND N/A compound on concrete Layer 1: Light gray SVF L1: ND N/A (w/ broken rock pattern) Original Building Layer 2: Beige paper L2: ND N/A 10527-C-73 2nd Floor backing w/ mastic Janitors Closet Layer 3: 9"x9" Black L3: 3% Chrysotile C-217 VAT Layer 4: Black mastic L4: 3% Chrysotile on wood Layer 1: 12"x12" Off- L1: ND N/A white/gray tile w/ yellow, brown, and white streaks Original Building Layer 2: Yellow mastic L2: ND N/A 10527-C-74 2nd Floor Storage 3: Gray leveling L3: ND N/A Room C-218 compound Layer w/mastic Layer 4: 9"x9" Black L4: 3% Chrysotile VAT Layer 5: Black mastic L5: 3% Chrysotile on wood Original Building Layer 1: White skim coat L1: ND N/A 10527-C-752nd Floor w/ paint Layer 2: Plaster on GWB L2: ND N/A Original Building Yellow carpet mastic on 10527-C-76 2nd Floor Dark wood ND N/A Room C-219 Layer 1: Yellow carpet L1: ND N/A Original Building mastic 10527-C- 2nd Floor Layer 2: 9"x9Dark red L2: 11% Chrysotile VAT 77QAx Corridor C-216 Layer 3: Black mastic L3: 3% Chrysotile Layer 4: Wood L4: ND N/A 38 EHS-International,Inc. Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Yellow carpet Li: ND N/A Original Building mastic 10527-C-78 2"d Floor E. CR C- Layer 2: Gray leveling L2: ND N/A 202 compound w/ paint, at door threshold on wood Layer 1: Yellow/brown L1: ND N/A carpet mastic Layer 2: Residual black L2: 2% Chrysotile Original Building mastic 10527-C-79 2nd Floor E. CR C- Layer 3: Brown fiber L3: ND N/A 206 board Layer 4: Clear mastic L4: ND N/A Layer 5: Hard wood floor L5: ND N/A Layer 6: Black asphaltic L6: ND N/A vapor barrier Original Building Layer 1: 1'x1' ACT w/ L1: ND N/A 10527-C-80 2nd Floor Men's metal cover Restroom C-220 Layer 2: Brown mastic L2: ND N/A Original Building Layer 1: Skim coat w/ L1: ND N/A 10527-C-81 2nd Floor E. CR C- paint 201 Layer 2: Plaster walls L1: ND N/A Original Building Layer 1: Skim coat w/ L1: ND N/A 10527-C-82 2nd Floor E. CR C- paint 201 Layer 2: Plaster walls L1: ND N/A Original Building Layer 1: Skim coat w/ Li: ND N/A 10527-C-83 2nd Floor Corridor paint C-216 Layer 2: Plaster walls L1: ND N/A Original Building Layer 1: JC w/ paint Li: 0.25% Chrysotile 10527-C-84*2 2nd Floor Men's Layer 2: Brown GWB L2: ND N/A Restroom C-220 (corner) Original Building Brown GWB w/ paper 10527-C-85 2nd Floor Men's ND N/A Restroom C-220 (mid wall) Original Building Layer 1: Skim coat w/ L1: ND N/A 10527-C-86 2nd Floor Corridor paint C-216 Layer 2: GWB w/ paper L2: ND N/A (mid wall) Original Building Layer 1: Skim coat w/ L1: ND N/A 10527-C-87 2nd Floor E. CR. C- paint 203 Layer 2: GWB w/ paint L2: ND N/A and paper, (corner) Original Building Layer 1: Skim coat w/ L1: 0.5% Chrysotile 10527-C-88*2 2nd Floor E. CR. C- paint 203 Layer 2: GWB w/ paper L2: ND N/A (mid wall) ehsi 39 EHS-International,Inc. • w Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: 4"Tan cove base L1: ND N/A Original Building Layer 2: Cream colored L2: ND N/A 10527-C-89 2nd Floor E. CR. C- mastic 207 Layer 3: JC w/ paint and L3: ND N/A paper Original Building Black asphaltic vapor 2nd Floor Men's 10527-C-90 Restroom C 220, barrier(between wood ND N/A pipe chase sub floor) Original Building 10527-C-91 2nd Floor Men's Plaster wall ND N/A Restroom C-220, pipe chase Original Building Layer 1: Yellow/tan L1: ND N/A 10527-C-92 2nd Floor E. CR. C- mastic 206 Layer 2: Tack board L1: ND N/A 10527-C-93 Original Building Light gray duct flange ND N/A 2nd Floor Attic sealant 10527-C-94 Original Building Green/gray duct seam ND N/A 2nd Floor Attic sealant 10527-C- Original Building NicoliteTM paper (in fire 56% Chrysotile 95QAx 2nd Floor Attic walls) 10527-C-96 Original Building Black asphaltic sealant 5% Chrysotile 2nd Floor Attic (at vent penetration) Original Building Black asphaltic vapor 10527-C-972nd Floor Attic barrier (behind old wood ND N/A siding) Addition Section Tan paper backing w/ 10527-C-98 Attic black mastic(under ND N/A fiberglass batt insulation) Original Building Layer 1: White TSI L1: ND N/A 10527-C-99laggi 2nd Floor Room Laye g2: White MAG TSI L2: 55% Chrysotile (Replacement of on small bore pipe run Stairs) (abandoned in wall) Building Addition 2'x4' SACT w/ pin hole 10527-C-100 2nd Floor E. CR. C- and worm track pattern ND N/A 212 Layer 1: 1'x1' ACT w/ L1: ND N/A Building Addition pinhole pattern 10527-C-101 2nd Floor E. CR. C- Layer 2: Brown/black L2: ND N/A 212 mastic Layer 3: GWB (ceiling) L3: ND N/A SIa. .. EHS-International,Inc. 40 I • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Building Addition JC/GWB w/paint and 10527-C-102 2nd Floor E. CR. C- ND N/A 215 paper (ceiling, at seam) Layer 1: Yellow carpet Li: ND N/A Building mastic 10527-C- Addition 2nd Layer 2: 9"x9" Gray L2: 2% Chrysotile 103 Floor E. CR. C- VAT 212 Layer 3: Black mastic L3: 2% Chrysotile Layer 4: Wood sub floor L4: ND N/A Building Addition Layer 1:Yellow mastic w/ L1: ND N/A 10527-C-104 2nd Floor E. CR. C- residual black mastic 211 Layer 2: Wood sub-floor L2: ND N/A Layer 1: 4" Gray cove L1: ND N/A Building Addition base L2: ND N/A 10527-C-105 2nd Floor E. CR. C- Layer 2: Cream mastic L3: ND N/A 211 Layer 3: Residual brown mastic w/ paint and paper Building Addition 10527-C-106 2nd Floor E. CR. C- GWB (mid wall) ND N/A 213 Building Addition Layer 1: JC w/ paint L1: ND N/A 10527-C-107 2nd Floor Corridor Layer 2: GWB w/ paper L2: ND N/A C-214 (seam) 10527-C- Building Addition Layer 1: JC w/ paint L1:0.75% Chrysotile 108*2 2nd Floor E. CR. C- Layer 2: GWB w/ paper L2: ND N/A 211 (corner) Building Addition Layer 1: 4"Tan cove base L1: ND N/A 10527-C-109 2nd Floor E. CR. C- Layer 2: Brown mastic w/ L2: ND N/A 215 paper and paint Building Addition Layer 1: JC w/ paint L1: ND N/A 10527-C-110 1st Floor Layer 2: GWB w/ paper L2: ND N/A Conference C-118 (corner) Building Addition GWB w/ paint andp ap er 10527-C-111 1st Floor Principal (mid wall) ND N/A C-120 Building Addition Layer 1: JC w/ seam tape L1: ND N/A 10527-C-112 1st Floor Nurse and paint Toilet C-127 Layer 2: GWB w/ paper L2: ND N/A (seam) Building Addition Layer 1: JC w/ paint L1: ND N/A 10527-C-113 1st Floor Nurse Layer 2: Skim coat L2: ND N/A Toilet C-127 Layer 3: GWB w/ paper L3: ND N/A (mid wall) s e) EHS-International,Inc. 41 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 • July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Building Addition Layer 1: 1'x1' ACT w/ pin L1: ND N/A 10527-C-114 1st Floor Nurse hole pattern Toilet C-128 Layer 2: Brown glue dot L2: ND N/A Layer 3: GWB w/ paper L3: ND N/A 10527-C-115 Building Addition 2'x4' SACT w/ worm track ND N/A 1st Floor VP C-124 and pin hole pattern Layer 1: Gray SVF Li: ND N/A Building Addition Layer 2: Beige paper L2: ND N/A 10527-C-116 1st Floor Nurse backing w/ mastic Toilet C-127 Layer 3: Gray leveling L3: ND N/A compound on residual black mastic on concrete Layer 1: 12"x12" Off- L1: ND N/A white/gray VCT (w/ 10527-C- Building brown, yellow and white 117QAX Addition 1st Floor streaks) Nurse C-126 Layer 2: Yellow mastic L2: ND N/A Layer 3: Residual black L3: 3% Chrysotile mastic on concrete Building Addition Layer 1: Skim coat w/ L1: ND N/A 10527-C-118 1St Floor Nurse paint Toilet C-127 Layer 2: GWB w/ paper L2: ND N/A (mid wall) Building Addition Layer 1: JC w/ paint L1: ND N/A 10527-C-119 1st Floor Clerical C- Layer 2: GWB w/ paper L2: ND N/A 122 Corridor (corner) Building Addition Layer 1: JC w/ paint L1: ND N/A 10527-C-120 1st Floor BKPR C- Layer 2: GWB w/ paper L2: ND N/A 131 (mid wall) Building Addition Layer 1: White 1'x1' ACT L1: ND N/A 10527-C-121 1st Floor V.P. C- paint 1 123 Layer 2: 'x1' ACT L2: ND N/A Layer 3: Brown glue dot L3: ND N/A Layer 1: Yellow carpet L1: ND N/A mastic Building 10527-C- Addition 1st Floor Layer 2: 9 x9„ Off- L2: 2% Chrysotile 122 white VAT V.P. C-125 Layer 3: Black mastic o on concrete L1: 3 /o Chrysotile Building Addition Layer 1: Yellow carpet L1: ND N/A 10527-C-123 1st Floor V.P. C- mastic 124 Layer 2: Gray leveling L2: ND N/A compound on concrete ehsi akit 42 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Yellow carpet L1: ND N/A Building mastic rr 10527-C- Addition 15t Floor Layer 2: 9"x9" Gray L2: 3% N/A 124 VAT V.P. C-123 Layer 3: Black mastic L3: 3% N/A on concrete Layer 1: Yellow carpet L1: ND N/A Building mastic 10527-C- Addition 1st FloorLayer 2: Gray leveling L2: ND N/A 125QAx Principal compound Corridor Layer 3: Residual black L3: 3% Chrysotile mastic on concrete Building Addition 10527-C-126 1st Floor Office C- White sink undercoat ND N/A 128 Building Addition Layer 1: Yellow carpet L1: ND N/A 10527-C-127 1st Floor Work C- mastic 130 Layer 2: Off-white VCT L2: ND N/A Layer 3: Yellow mastic L3: ND N/A BLOCK D Layer 1: 4"Tan cove base L1: ND N/A Layer 2: Tan mastic 10527-D-01 Library D-15 Layer 3: Residual brown L2: ND N/A mastic L3: ND N/A Layer 1: Blue carpet L1: ND N/A Layer 2: Yellow/tan L2: ND N/A 10527-D-02 Library D-15 mastic Layer 3: Residual black L3: 3% Chrysotile mastic on concrete Layer 1: 1'x1' White ACT L1: ND N/A (with random pinhole Library D-15, pattern) L2: ND N/A 10527-D-03 Reception Area Layer 2: Dark brown glue dot Layer 3: Unfinished GWB L3: ND N/A (pinkish color) White NicoliteTM paper 10527-D-04 Library Attic (in fire wall) 65% Chrysotile Layer 1: Silver coat/paint L1:ND N/A 10527-D-05 Library Attic Layer 2: Black asphaltic L2: 5% Chrysotile tar/sealant ehsi EHS-International,Inc. 43 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Blue carpet L1: ND N/A Layer 2: Yellow/tan L2: ND N/A 10527-D-06 Library D15 mastic Layer 3: Residual black L3: 3% Chrysotile mastic on concrete Layer 1: Gray carpet foam L1: ND N/A backing Layer 2: Clear mastic L2: ND N/A Layer 3: 12"x 12" Off- L3: ND N/A 10527-D-07 MAG D-20 white VCT (with brown, yellow, and white streaks) Layer 4: Yellow mastic L4: ND Layer 5: Residual black 15: 3% N/A mastic on concrete Chrysotile Layer 1: Blue carpet L1: ND N/A Layer 2: Yellow/tan L2: ND N/A mastic 10527-D-08 Library D-15 Layer 3: Residual black L3: 3% Chrysotile mastic Layer 4: White material L4: ND N/A on concrete 10527-D-09 Library Attic Green/gray duct seam ND N/A sealant 10527-D-10 South Storage White sink undercoat ND N/A Room 2'x4' SACT (with worm 10527-D-11 A.V.CR. D-17 track and pin hole ND N/A pattern) Layer 1: 1'x1' White ACT L1: ND N/A (with random pin hole 10527-D-12 A.V.CR. D-17 Pattern) Layer 2: Dark brown glue L2: ND N/A dot Layer 3: Unfinished GWB L3: ND N/A Layer 1: Carpet L1: ND N/A Layer 2: Brown mastic L2: ND N/A Layer 3: Orange mastic L3: ND N/A 10527-D- Corridor D-14 Layer 4: 9"x 9" Tan L4: 2% Chrysotile 13QAx VAT (with white and brown streaks) Layer 5: Black mastic L5: 4% Chrysotile on concrete ehsi.. EHS-International,Inc. 44 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: 4" Gray cove L1: ND N/A base w/paint 10527-D-14 Corridor D-14 Layer 2: Cream mastic L2: ND N/A Layer 3: Residual brown L3: ND N/A mastic Layer 1: 4" Black cove L1: ND N/A 10527-D-15 MAG D-20 base Layer 2: Cream mastic w/ L2: ND N/A GWB paper and paint 10527-D-16 South Storage GWB with paint (mid wall) ND N/A Room South Storage Layer 1: JC (patch) L1: ND N/A 10527-D-17 Room Layer 2: GWB w/ paint L2: ND N/A and paper (mid ceiling) South Storage Layer 1: JC w/ paint L1: ND N/A 10527-D-18 Room Layer 2: GWB w/ paper L2: ND N/A (ceiling edge) Layer 1: JC w/ paint L1: 0.5% Chrysotile 10527-D-19*3 A.V. CR. D-17 Layer 2: GWB w/ paper L2: ND N/A (mid wall) 10527-D-20 Library D-15 GWB w/ paint and paper ND N/A (mid wall) Layer 1: White skim coat L1: ND N/A 10527-D-21 Library D-15 w/ paint Layer 2: Plaster column L2: ND N/A Layer 1: White skim coat L1: 0.25% Chrysotile 10527-D-22*3 Library D-15 w/ paint Layer 2: Plaster column L2: ND N/A 10527-D-23 Library D-15 Plaster w/ paint on ND N/A column Layer 1: JC w/ paint L1: ND N/A 10527 D 24*3 MAG D-20 Layer 2: JC w/ paint L2: 0.5% Chrysotile Layer 3: GWB w/ paper L3: ND N/A (corner wall) Layer 1: JC w/ paint L1: 0.5% Chrysotile 10527-D-25*3 Library D-15 Layer 2: GWB w/ paper L2: ND N/A (mid wall) 10527-D-26 South Storage GWB w/ paint and paper ND N/A Room (corner wall) Layer 1: 2" Beige ceramic L1: ND N/A wall tile 10527-D-27*3 Library D-15 Layer 2: White grout L2: ND N/A Layer 3: Yellow mastic L3: ND N/A Layer 4: GWB L4: 0.75% Chrysotile ehs14 EHS-International,Inc. 45 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: 1'x1' White ACT L1: ND N/A (w/ worm track and pin 10527-D-28 Corridor D-14 hole pattern) Layer 2: Brown glue dot L2: ND N/A Layer 3: JC L3: ND N/A Layer 4: GWB (seam) L4: ND N/A Layer 1: JC w/ paint L1: 0.5% Chrysotile Layer 2: Wall joint tape L2: ND N/A 10527-D-29*3 Building Addition Layer 3: Old JC on L3: 0.5% Chrysotile SS. CR. D-5 partition wall w/ paper Layer 4: Old GWB L4: ND N/A partition wall w/ paper Layer 1: 1'x1' White ACT L1: ND N/A 10527-D-30 Building Addition (w/ worm track and pin Corridor D-13 hole pattern) Layer 2: Brown glue dot L2: ND N/A Layer 1: 4"Tan cove base L1: ND N/A 10527-D- Building Addition Layer 2: Cream mastic 31QA SS. CR. D-5 Layer 3: Residual brown L2: ND N/A mastic L3: ND N/A Layer 1: Blue carpet L1: ND N/A 10527-D-32 Building Addition Layer 2: Yellow mastic L2: ND N/A SS. CR. D-5 Layer 3: Residual dark L3: ND N/A gray mastic on concrete Layer 1: Yellow carpet L1: ND N/A Building Addition mastic 10527-D-33 SS. CR. D-7 Layer 2: White leveling L2: ND N/A compound Layer 3: Concrete L3: ND N/A Layer 1: Yellow carpet L1: ND N/A mastic 10527-D-34 Building Addition Layer 2: Dark gray mastic L2: ND N/A SS. CR. D-6 Layer 3: Light gray leveling compound on L3: ND N/A concrete Layer 1: 4" Light gray L1: ND N/A 10527-D-35 Building Addition cove base SS. CR. D-8 Layer 2: White mastic L2: ND N/A Layer 3: JC w/ paint L3: ND N/A Layer 1: Gray foam carpet L1: ND N/A Building backing 10527-D-36 Addition Layer 2: Clear/yellow L2: ND N/A Corridor D-13 mastic Layer 3: Residual black L3: 3% Chrysotile mastic on concrete '"" s `e 46 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Building Addition Layer 1: Black foam L1: ND N/A 10527-D-37 carpet backing Conference D-12 Layer 2: Beige mastic L2: ND N/A Building Addition GWB w/ paint and paper 10527-D-38 Corridor D-13 (mid wall) ND N/A 10527-D-39 Building Addition GWB w/ paint and paper ND N/A S.S. CR. D-1 (mid wall) 10527-D-40 Building Addition Layer 1: JC w/ paint L1: ND N/A D-4 Layer 2: GWB w/ paper L2: ND N/A Layer 1: JC w/ paint L1: ND N/A 310527-D-41Building Addition Layer 2: JC w/ paint L2: 0.5% Chrysotile D-4 Layer 3: GWB w/ paper L3: ND N/A (corner wall) Building Addition Layer 1: JC w/ paint L1: ND N/A 10527-D-42D 7 Layer 2: GWB w/ paper L2: ND N/A (corner wall) 10527-D- Building 43QAx Addition Office Black sink undercoat 5% Chrysotile D-11 10527-D-44 Building Addition Black foam window ND N/A SS. CR. D-7 glazing w/ clear mastic Layer 1: Gray door frame L1: ND N/A 10527-D-45 Building Addition caulking on double door Layer 2: Brick debris L2: ND N/A Layer 3: Gray mortar L3: ND N/A BLOCK E L1: ND N/A Layer 1: Blue carpet L2: ND N/A 10527-E-01 Classroom E-17 Layer 2: Yellow mastic L3: Not Layer 3: White leveling mentioned by the Lab Layer 1: 4"Tan cove base L1: ND N/A 10527-E-02 Classroom E-17 Layer 2: Cream mastic L2: ND N/A Layer 1: White paint L1: ND N/A Layer 2: Silver foil L2: ND N/A 10527-E-03 Corridor E-22 Layer 3: White mastic L3: ND N/A Layer 4: 2'x4' White L4: ND N/A SACTw/ pin hole pattern ehsi EHS-International,Inc. 47 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: 12"x12" Off- L1: ND N/A white VCT Layer 2: Yellow mastic L2: ND N/A 10527-E-04 Janitor E-15 Layer 3: Black mastic L3: ND N/A Layer 4: Gray leveling L4: ND N/A compound on concrete floor Layer 1:12"x 12" Off- L1: ND N/A Drama Storage E- white VCT 10527-E-0519 Layer 2: Yellow mastic L2: ND N/A Layer 3: Residual black L3: ND N/A mastic on concrete Layer 1: 12"x 12" Light L1: ND N/A gray VCT (w/ gray and white streaks) 10527-E-06 Corridor E-8 Layer 2: Off-white/yellow L2: ND N/A mastic Layer 3: Residual black L3: 3% N/A mastic Layer 4: Concrete debris L4: ND N/A Layer 1: 12"x 12" Blue L1: ND N/A VCT 10527-E-07 Corridor E-8 Layer 2: Yellow mastic L2: ND N/A Layer 3: Residual black L3: 3% Chrysotile mastic on concrete 10527-E-08 Drama Storage E Tan pipe dope ND N/A Layer 1: Yellow carpet L1: ND N/A 10527-E-09 Vestibule E-25 mastic Layer 2: Residual black L2: 3% Chrysotile mastic Drama Storage E- Layer 1: White plaster L1: ND N/A 10527-E-10 19 Layer 2: GWB w/ paper L2: ND N/A on ceiling Drama Storage E- Layer 1: White plaster L1: ND N/A 10527-E-11 19 Layer 2: GWB w/ paper L2: ND N/A on ceiling Drama Storage E- Layer 1: White plaster L1: ND N/A 10527-E-12 19 Layer 2: GWB with paper L2: ND N/A on ceiling ehcry s1 . 48 ENS-international,Inc, • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Yellow carpet ND ND mastic Layer 2: Thin white L2: ND ND powdery material 10527-E- S.S.C.R E-21 Layer 3: Gray brittle ND ND 13QA material Layer 4: 9"x9" Light 3% Chrysotile blue VAT Layer 5: Black mastic L3: 5% Chrysotile on concrete Layer 1: 1'x 1' White ACT L1: ND N/A (with pin hole and worm 10527-E-14 Foyer E-18 track pattern) Layer 2: Brown glue dot L2: ND N/A Layer 3: GWB paper L3: ND N/A Layer 1: 9"x 9" Light L1: 3% Chrysotile 10527-E-15 Theater E-10 brown VAT Layer 2: Black mastic L2: 3% Chrysotile on concrete 10527-E-16 S.S.C.R E-21 2'x4' SACT (with worm ND N/A track and pinhole pattern) Layer 1: 2" Gray ceramic L1: ND N/A floor tile 10527-E-17 Men's Restroom Layer 2: Dark gray grout L2: ND N/A E-5 Layer 3: Cream mastic L3: ND N/A Layer 4: Gray leveling L4: ND N/A compound on concrete Layer 1: 4" White ceramic L1: ND N/A wa II 10527-E-18 E 5's Restroom La 10527-E-18 Light brown L2: ND N/A grout Layer 3: White mastic L3: ND N/A Layer 1: Newer white sink Li: ND N/A 10527-E-19 Men's Restroom caulking E-5 Layer 2: Older white sink L2: ND N/A caulking Layer 1: 1'xl' ACT (with Li: ND N/A 10527-E-20 Greenroom E-7 fissure pattern) Layer 2: Brown glue dot L2: ND N/A 10527-E-21 Greenroom E-7 Gray duct seam sealant ND N/A Layer 1: 4" Black cove L1: ND N/A base 10527-E-22 Theater E-10 Layer 2: Brown mastic L2: ND N/A Layer 3: Residual dark L3: ND N/A brown mastic ehsi EHS-International.Inc. 49 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 ` July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS 10527-E-23 Drama Cr. E-1 Residual brown cove base ND N/A on casework Layer 1: Black foam L1: ND N/A window glazing 10527-E-24 Drama Cr. E-1 Layer 2: Clear mastic L2: ND N/A Layer 3: Gray window L3: ND N/A glazing 10527-E-25 Greenroom E-7 White sink undercoat ND N/A Layer 1: Yellow/orange L1: ND N/A carpet mastic 10527-E- Greenroom E-7 Layer 2: 9"x 9" Tan L2: 4% Chrysotile 26QAX VAT Layer 3: Black mastic L3: 3% Chrysotile on concrete 10527E Dressing Room E- Layer 1: White skim coat L1: ND N/A 27QA 5 Layer 2: Old gray plaster L2: ND N/A Layer 3: GWB with paper L3: ND N/A Dressing Room E- Layer 1: White skim coat L1: ND N/A 10527-E-286 Layer 2: Old gray plaster L2: ND N/A Layer 3: GWB with paper L3: ND N/A Dressing Room E- Layer 1: White skim coat L1: ND N/A 10527-E-296 Layer 2: Old gray plaster L2: ND N/A Layer 3: GWB with paper L3: ND N/A Layer 1: Silver foil Li: ND N/A Dressing Room E- Layer 2: Paper backing w/ L2: ND N/A 10527-E-305 black mastic Layer 3: Black fiberglass L3: ND N/A batting insulation Layer 1: White skim coat L1: ND N/A 10527-E-31 Men Restroom E-3 w/ paint Layer 2: Gay plaster on L2: ND N/A ceiling Layer 1: White skim coat L1: ND N/A 10527-E-32 Men Restroom E-3 w/ paint Layer 2: Gay plaster on L2: ND N/A ceiling Layer 1: White skim coat L1: ND N/A 10527-E-33 Men Restroom E-3 w/ paint Layer 2: Gay plaster on L2: ND N/A ceiling Layer 1: 1'x i' ACT (w/ L1: ND N/A 10527-E-34 Stage E-9 large pin hole pattern) Layer 2: Brown glue dot L2: ND N/A on plaster ceiling 10527-E-35 Stage E-9 Plaster on GWB ceiling ND N/A ' i/ 50 EHS-International,Inc. e 0 Limited Hazardous Materials Survey Report Federal Way High School :' EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: White skim coat L1: ND N/A 10527-E-36 Stage E-9 w/ paint Layer 2: Gay plaster on L2: ND N/A ceiling Layer 1: White skim coat L1: ND N/A 10527-E-37 Stage E 9 w/ Paint Layer 2: Gay plaster on L2: ND N/A ceiling Layer 1: White skim coat L1: ND N/A 10527E Theater E-10 w/ Paint 38QA Layer 2: Gay plaster on L2: ND N/A ceiling Layer 1: White skim coat L1: ND N/A 10527-E-39 Theater E-10 w/ Paint Layer 2: Gay plaster on L2: ND N/A ceiling Layer 1: JC w/ paint and L1: ND N/A 10527-E-40 Classroom E-17 Paper Layer 2: GWB with paper, L2: ND N/A mid wall Layer 1: JC w/ paint and L1: ND N/A 10527-E-41 FoyerE-18 paper Layer 2: GWB w/ paper L2: ND N/A (mid wall) Layer 1: JC w/ paint and L1: ND N/A 10527-E-42 Corridor E-8 paper Layer 2: GWB w/ paper L2: ND N/A (mid wall) Layer 1: JC w/ paint L1: ND N/A 10527-E-43 Foyer E-18 Layer 2: GWB w/ paper (corner wall) L2: ND N/A Layer 1: JC w/ paint and L1: ND N/A 10527-E-44 S.S.C.R E-21 paper Layer 2: GWB w/ paper L2: ND N/A (corner wall) Layer 1: Blue/green L1: ND N/A carpet Layer 2: Gray foam L2: ND N/A 10527-E-45 Block E Addition, backing Room 3 Layer 3: Yellow/clear L3: ND N/A mastic Layer 4: Gray leveling L4: ND N/A compound on concrete ehsi.. s> EHS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 • July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: White door frame L1: ND N/A 10527-E-46 Corridor E-8 caulking Layer 2: Beige door frame L2: ND N/A caulking w/paint Layer 1: Gray window L1: ND N/A 10527-E-47 Block E Addition, frame caulking Room 3 Layer 2: Black foam L2: ND N/A insulation Block E Addition Layer 1: JC L1: ND N/A 10527-E-48 Layer 2: GWB w/ paper, L2: ND N/A Corridor corner wall 10527-E-49 Block E Addition GWB w/ paper (mid wall) ND N/A Corridor 10527E 50 Block E Addition, GWB w/ paint and paper ND N/A Room 4 (mid wall) 10527-E-51 Block E Addition, Gray duct seam sealant ND N/A Room 2 Block E Addition Layer 1: JC L1: ND N/A 10527-E-52 Corridor Layer 2: GWB w/ paper L2: ND N/A (ceiling seam) Block E Addition, Layer 1: 4"Tan cove base L1: ND N/A 10527-E-53 Room 5 Layer 2: Cream mastic L2: ND N/A Layer 3: JC w/ paint L3: ND N/A 10527E 54 Block E Addition, Blue paint on new plaster ND N/A Room 3 ceiling 10527E 55 Block E Addition, Blue paint on new plaster ND N/A Room 3 ceiling 10527E 56 Block E Addition, Blue paint on new plaster ND N/A Room 4 ceiling BLOCK F L1: ND N/A Layer 1: 12"x12" Off- White VCT (w/ brown, 10527-F-01 Sewing F-8 yellow, and white streaks) Layer 2: Yellow mastic L2: ND N/A Layer 3: Residual black L3: 3% Chrysotile mastic on concrete Layer 1: 12"x12" Blue L1: ND N/A VCT w/ shades of blue 10527-F-02 Cooking F-4 Layer 2: Yellow mastic L2: ND N/A Layer 3: White leveling L3: ND N/A compound Layer 4: Concrete debris L4: ND N/A e SIS.. 52 EHS-International,Inc. s �r Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: 9"x9" Tan VAT L1: 3% Chrysotile (w/ brown and yellow 10527-F-03 Electrical F-1 streaks) Layer 2: Black mastic L2: 3% Chrysotile on concrete Layer 1: 9"x9" Light L1: 3% Chrysotile Brown VAT (w/ 10527-F-04 Electrical F-1 rainbow streaks) Layer 2: Black mastic L2: 3% Chrysotile on concrete 10527-F-05 West Mechanical Gray pipe dope on gas ND N/A Room line fittings 10527-F-06 West Mechanical Yellow pipe dope on gas ND N/A Room line fittings Layer 1: White skim coat Li: ND N/A 10527-F- West Mechanical w/ paint 07QA Room Layer 2:Plaster wall L2: ND N/A Layer 3: GWB L3: ND N/A 10527-F-08 Cooking F-4 Gray sink undercoat ND N/A 10527-F-09 Cooking F-4 White sink undercoat ND N/A East Mechanical Layer 1: White paint on Li: ND N/A 10527-F-10 Room (Storage 1x1 ACT Room) Layer 2: 1x1' ACT L2: ND N/A Layer 3: Brown glue dot L3: ND N/A Layer 1: White paint on L1: ND N/A 1'x l' ACT 10527-F-11 Corridor F-10 Layer 2: 1'x1' Gray ACT L2: ND N/A Layer 3: Brown glue dot L3: ND N/A Layer 4: GWB (ceiling) L4: ND N/A Layer 1: 9"x9" Olive L1:2% N/A 10527-F-12 Biology CR green VAT Layer 2: Black mastic L2: 3% N/A on concrete 10527-F-13 Biology CR Pink sink undercoat ND N/A 10527-F-14 Biology CR Black counter top ND N/A Layer 1: 4" Black cove L1: ND N/A 10527-F-15 Biology CR base Layer 2: Brown mastic on L2: ND N/A casework 10527-F-16 Biology CR White sink undercoat on ND N/A ceramic sinks Layer 1: 9"x9" L1: 3% Chrysotile 10527-F-17 Storage F-17 Brown/red VAT Layer 2: Black mastic L2: 3% Chrysotile on concrete ehsi.) EHS-International,Inc. 53 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: (Carpet on) L1: 2% Chrysotile 12'x12" Beige VAT (w/ 10527-F-18 Electronics F-19 brown streaks) Layer 2: Black mastic L2: 3% Chrysotile on concrete Layer 1: Off-white SVF w/ L1: ND N/A rock pattern 10527-F-19 Toilet F-12 Layer 2: Gray paper L2: ND N/A backing w/ yellow mastic on concrete Layer 1: Yellow carpet L1: ND N/A mastic L2: 3% Chrysotile 10527-F-20 Special Ed F-13 Layer 2: 9"x9Red VAT Layer 3: Black mastic L3: 3% Chrysotile on concrete Layer 1: Green/Gray L1: ND N/A carpet mastic Layer 2: Yellow carpet L2: ND N/A mastic 10527-F-21 Special Ed. F-15 Layer 3: 9"x9" Light L3: 3% Chrysotile brown VAT (w/ rainbow streaks) Layer 4: Black mastic L4: 3% Chrysotile on concrete 10527-F-22 Drafting F-16 Black sink undercoat 2% Chrysotile 10527-F-23 Drafting F-16 GWB (mid wall) ND N/A Child Development Layer 1: JC w/ paint L1: ND N/A 10527-F-24 F-11 Layer 2: GWB w/ paper L2: ND N/A (corner) Layer 1:White skim coat L1: ND N/A 10527-F-25 Corridor F-15 w/ paint Layer 2: Plaster wall L2: ND N/A Layer 1: 1'x1' ACT L1: ND N/A 10527-F-26 Drafting F-16 Layer 2: Brown glue dot L2: ND N/A Layer 3: Texturing L3: ND N/A overspray Layer 1: 1'x1' ACT L1: ND N/A 10527-F- Layer 2: Brown glue dot L2: ND N/A Drafting F-16 27QA Layer 3: Texturing L3: ND N/A overspray Layer 1: Trace of L1: ND N/A 10527-F-28 Cooking F-4 texturing overspray Layer 2: GWB paper L2: ND N/A Layer 3: GWB L3: ND N/A ehsi. 54 EHS-International,Inc. 111 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Yellow mastic L1: ND N/A (beneath 12"x12" light gray VCT) 10527-F-29 Corridor F-15 Layer 2: Gray leveling L2: ND N/A compound Layer 3: Residual Black L3: ND N/A mastic BLOCK G Layer 1: 12"x12" Light L1: ND N/A gray VCT (with white and gray streaks) Corridor G-13, Layer 2: Tan mastic L2: ND N/A 10527-G-01 Outside Boys Layer 3: White leveling L3: ND N/A Restroom G-12 compound Layer 4: Gray VAT L4: 2% Chrysotile Layer 5: Black mastic L5: 3% Chrysotile on wood Layer 1: 12"x12" Blue L1: ND N/A VCT Corridor G-13, Layer 2: Tan mastic L2: ND N/A 10527-G-02 Outside Boys Layer 3: White leveling L3: ND N/A Restroom g-12 compound o Layer 4: Gray VAT L4: 2% Chrysotile Layer 5: Black mastic L5: 3% Chrysotile on wood Layer 1: 12"x12" gray L1: ND N/A VCT (with maroon streaks) Layer 2: Tan mastic L2: ND N/A 10527-G-03 Storage G10A Layer 3: White leveling L3: ND N/A compound Layer 4: Gray VAT L4: 2% Chrysotile Layer 5: Black mastic 15: 3% Chrysotile on wood Layer 1: 2" Red/tan L1: ND N/A ceramic floor tile 10527-G-04 Boys Restroom G- Layer 2: Dark gray grout L2: ND N/A 12 Layer 3: Light gray mortar L3: ND N/A Layer 4: Trace yellow mastic L4: ND N/A Layer 1: 4" White ceramic L1: ND N/A 10527-G-05 Boys Restroom g- cove base 12 Layer 2: Dark gray grout L2: ND N/A Layer 3: Light gray mortar L3: ND N/A ehsi EHS-International.Inc. 55 • S Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Blue/gray carpet L1:ND N/A Micro Computer Layer 2: Tan mastic L2: ND N/A 10527-G-06G-7 Layer 3: Tan VAT L3: 2% Chrysotile Layer 4: Black mastic L4: 3% Chrysotile on wood Layer 1: Blue gray carpet L1: ND N/A Layer 2: Tan mastic 10527-G-07 Bus Office G-10 Layer 3: Gray VAT L2: ND N/A Layer 4: Black mastic L3: 2% Chrysotile on wood L4: 3% Chrysotile 10527-G-08 Bus Office G-10 2'x4' SACT (with pin hole ND N/A and worm track pattern) Layer 1: 1'x 1' ACT (with L1: ND N/A 10527-G-09 Bus Office G-10 pin hole pattern) Layer 2: Brown glue dot L2: ND N/A w/ paint Layer 1: Gray paint L1: ND N/A 10527-G-10 Storage G l0A Layer 2: White skim coat L2: ND N/A Layer 3: GWB with paper L3: ND N/A (mid ceiling) Layer 1: Gray paint L1: ND N/A 10527-G-11 Janitor Closet G-9 Layer 2: White skim coat L2: ND N/A Layer 3: GWB with paper L3: ND N/A (mid ceiling) 10527-G-12 Computer E-5 ACT)GWB (beneath 1'x1' ND N/A 10527-G-13 Micro Computer G- Bare GWB (beneath 1'x1' ND N/A 7 ACT) Micro Computer G- Layer 1: Residual ACT L1: ND N/A 10527-G-147 Layer 2: Brown glue dot L2: ND N/A w/paint, on wall Layer 1: Multi-colored L1: ND N/A Micro Computer G- paint 10527-G-157 Layer 2: White skim coat L2: ND N/A Layer 3: Gray plaster L3: ND N/A beneath GWB wall Layer 1: Gray paint L1: ND N/A 10527-G-16 Girls Restroom E-5 Layer 2: White skim coat L2: ND N/A Layer 3: GWB with paper L3: ND N/A (mid ceiling) Layer 1: Tan paint L1: ND N/A 10527-G-17 Boys Restroom G- Layer 2: White skim coat L2: ND N/A 12 Layer 3: Gray plaster on L3: ND N/A ceiling ehaSim EHS-International,Inc. 56 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Tan paint L1: ND N/A 10527-G-18 Boys Restroom G- Layer 2: White skim coat L2: ND N/A 12 Layer 3: Gray plaster on L3: ND N/A ceiling Layer 1: Tan paint L1: ND N/A 10527-G-19 Bus Office G-10 Layer 2: White skim coat L2: ND N/A Layer 3: Gray plaster on L3: ND N/A ceiling Layer 1: Brown glue dot L1: ND N/A 10527-G-20 Boys Restroom G- Layer 2: Tan/gray paint L2: ND N/A 12 Layer 3: Gray plaster on L3: ND N/A ceiling Layer 1: Tan paint L1: ND N/A 10527-G- Layer 2: White skim coat L2: ND N/A 21QA Bus Office G-10 Layer 3: Gray plaster on L3: ND N/A ceiling 10527-G-22 Boys Restroom G Tan pipe dope w/debris ND N/A Layer 1: Multi-colored L1: ND N/A paint 10527-G-23 Bus C.R G-4 Layer 2: White skim coat L2: ND N/A Layer 3: Gray plaster, mid L3: ND N/A wall (beneath GWB) L1: ND N/A Layer 1: 4"Tan cove base 10527-G-24 Corridor G-13 Layer 2: Off-white mastic L2: ND N/A Layer 3: Trace JC L3: ND N/A Layer 1: Beige paint L1: ND N/A Layer 2: White skim coat L2: ND N/A 10527-G-25 Simulators G-1 with yellow wall seam tap Layer 3: GWB with paper (corner wall) L3: ND N/A Layer 1: Beige paint L1: ND N/A 10527-G-26 Computer G-5 Layer 2: White skim coat L2: ND N/A Layer 3: GWB with paper L3: ND N/A (mid wall) Layer 1: Beige paint L1: ND N/A 10527-G-27 Micro Computer G- Layer 2: White skim coat L2: ND N/A 7 Layer 3: GWB with paper L3: ND N/A (corner wall) Layer 1: Blue paint L1: ND N/A 10527-G-28 Corridor G-13 Layer 2: White skim coat L2: ND N/A Layer 3: GWB with paper L3: ND N/A (mid wall) ehsi EHS-International,Inc. 57 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Orange paint L1: ND N/A 10527-G-29 Boys Restroom G- Layer 2: White skim coat L2: ND N/A 12 Layer 3: GWB with paper L3: ND N/A (mid wall) Bare GWB w/paint (above 10527-G-30 Simulator G-1 1'x1' ACT w/ brown glue ND N/A dots) Layer 1: l'x 1' White ACT L1: ND N/A 10527-G-31 Corridor G-13 (with fissure pattern) Layer 2: Brown glue dot L2: ND N/A Layer 1: 4"x12" L1: ND N/A Boys Restroom G- Yellow/red ceramic wall 10527-G-3212 tile Layer 2: Gray grout L2: ND N/A Layer 3: Gray mortar L3: ND N/A 10527-G-33 Corridor G-13 Tan mastic w/paint ND N/A beneath door sign Layer 1: Tan/green paint L1: ND N/A 10527-G-34 Micro Computer G- Layer 2: White skim coat L2: ND N/A 7 Layer 3: Gray plaster L3: ND N/A (beneath GWB wall) Layer 1: Multi-colored L1: ND N/A Micro Computer G- paint 10527-G-357 Layer 2: White skim coat L2: ND N/A Layer 3: Gray plaster L3: ND N/A (beneath GWB wall) Layer 1: Multi-colored L1: ND N/A paint 10527-G-36 Bus C.R Layer 2: White skim coat L2: ND N/A Layer 3: Gray plaster L3: ND N/A (beneath GWB wall) 10527-G-37 Bus Office G-10 White sink undercoat ND N/A Gray window frame 10527-G-38 Bus C.R. G-4 caulking (on 5'x6' ND N/A aluminum framed window) Layer 1: 4" Pink ceramic L1: ND N/A 10527-G-39 Corridor G-13 wall tile Layer 2: Gray grout L2: ND N/A Layer 3: White mortar L3: ND N/A ehsi 58 EHS-International.Inc. Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: l'xl' White ACT L1: ND N/A 10527-G- with paint (fissure 40QA Corridor G-13 pattern) Layer 2: ACT debris L2: ND N/A Layer 3: Brown glue dot L3: ND N/A BLOCK H Layer 1: 12"x12" Beige L1: ND N/A 10527-H- VCT (w/ brown and white 01QAX Main Corridor streaks) Layer 2: Black mastic L2. 3% Chrysotile on concrete Layer 1: 12"x12" Beige Li: ND N/A VCT (w/ brown and white 10527-H-02 Janitor's Closet streaks) Layer 2: Black mastic L2: 3% Chrysotile on concrete Layer 1: White leveling L1: ND N/A compound 10527-H-03 Janitor's Closet Layer 2: Gray leveling L2: ND N/A compound Layer 3: Black mastic L3: 3% Chrysotile on concrete Layer 1: Multi-colored L1: ND N/A carpet w/ foam backing Layer 2: Trace clear L2: ND N/A mastic 10527-H-04 Office Layer 3: 12"x12" Beige L3: ND N/A VCT (w/ brown and white streaks) Layer 4: Black mastic L4: 3% Chrysotile on concrete Layer 1: Multi-colored L1: ND N/A 10527-H-05 ASA Room carpet w/ foam backing Layer 2: Tan mastic on L2: ND N/A concrete Layer 1: 12"x12" Multi- L1: ND N/A East Entry, Main colored carpet squares w/ 10527-H-06 Corridor rubber backing Layer 2: Tan mastic on L2: ND N/A concrete ehsi ENS-International.Inc. 59 i Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS L1: ND N/A Layer 1: 1"x1" Beige and gray ceramic floor tile L2: ND N/A 10527-H-07 Grooming 706 Layer 2: Trace gray grout Layer 3: Light gray mortar L3: ND N/A Layer 4: Beige mastic L4: ND N/A Layer 1: 1"xl" Beige L1: ND N/A ceramic cove base tile 10527-H-08 Grooming 706 Layer 2: Gray grout L2: ND N/A Layer 3: Light Gray L3: ND N/A mortar Layer 1: 4" Gray cove L1: ND N/A 10527-H-09 Main Corridor base Layer 2: Tan mastic L2: ND N/A Layer 1: Maroon colored L1: ND N/A 10527-H- mastic Room 704 10QA Layer 2: Wood from roof L2: ND N/A truss 10527-H-11 Room 705 2'x4' SACT w/ pin hole ND N/A and worm track pattern Layer 1: Silver foil Ll: ND N/A 10527-H-12 Room 704 Layer 2: Light brown L2: ND N/A paper (batt insulation) w/mastic L1: ND N/A Layer 1: Silver/gray cloth 10527-H-13 Grooming 706 Layer 2: Gray cloth L2: ND N/A Layer 3: Silver/gray cloth L3: ND N/A Layer 1: 1'x1' White ACT L1: ND N/A (w/ pin hole and worm 10527-H-14 Main Corridor track pattern) w/ paint Layer 2: Beige glue dot L2: ND N/A Layer 3: JC w/ paper L3: ND N/A Layer 4: GWB (ceiling) L4: ND N/A 10527-H-15 Main Corridor GWB (mid ceiling) ND N/A 10527-H-16 Main Corridor GWB (mid ceiling) ND N/A 10527-H-17 Room 704 Black sink undercoat ND N/A Layer 1: 4" Black cove L1: ND N/A base 10527-H-18 Room 704 Layer 2: Cream colored L2:ND N/A mastic Layer 3: Tan mastic L3: ND N/A e s .. 60 ENS-International,Inc. ! • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: 4"Tan cove base L1: ND N/A 10527-H-19 Office Layer 2: Tan mastic L2: ND N/A Layer 1: White skim coat L1: ND N/A 10527-H-20 Main Corridor w/ paint Layer 2: JC w/ paint L2: ND N/A Layer 3: GWB (mid wall) L3: ND N/A 10527-H-21 Room 704 GWB w/ paint and paper ND N/A (mid wall) 10527-H-22 ASA Room GWB w/ paint and paper ND N/A (mid wall) Layer 1: JC w/ paint L1: ND N/A 10527-H-23 Room 705 Layer 2: GWB w/ paper L2: ND N/A (corner) Layer 1: White skim coat L1: ND N/A 10527-H-24 Main Corridor, NE w/ paint Corner Layer 2: GWB w/ paper L2: ND N/A (mid wall) Layer 1: White skim coat L1: ND N/A 10527-H-25 Main Corridor, S. w/ paint Wall Layer 2: GWB w/ paper L2: ND N/A (mid wall) Layer 1: White skim coat L1: ND N/A 10527-H-26 Main Corridor w/ paint Outside Room 704 Layer 2: GWB, w/ paper L2: ND N/A (mid wall) Layer 1: White skim coat L1: ND N/A 10527-H-27 Central Corridor w/ paint Layer 2: JC w/ paint L2: ND N/A Layer 3: GWB (mid wall) L3: ND N/A Layer 1: Cloth covering w/ L1: ND N/A 10527-H-28 Office mastic Layer 2: GWB w/ paper L2: ND N/A Layer 1: White caulking L1: ND N/A Layer 2: White grout L2: ND N/A 10527-H-29 ASA Room Layer 3: Gray mortar L3: ND N/A (beneath ceramic window sill tiles) BLOCK J Layer 1: White skim coat L1: ND N/A 10527-J-01 Corridor J-11 w/ paint Layer 2: Gray plaster L2: ND N/A Layer 1: JC w/ paint L1: ND N/A 10527-J-02 Corridor J-11 Layer 2: GWB w/ paper L2: ND N/A (ceiling at seam) ehsi EHS-International.Inc. 61 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: JC w/ paint L1: ND N/A 10527-3-03 Girls J-3 Layer 2: GWB w/ paper L2: ND N/A (ceiling at seam) Layer 1: Yellow carpet L1: ND N/A mastic 10527-3-04 Math Classroom Layer 2: 9"x9" Brown/ L2: 3% Chrysotile 3-5 red VAT Layer 3: Black mastic on L3: ND N/A concrete Layer 1: Yellow mastic L1: ND N/A (beneath 12"x12" light gray VCT) Layer 2:Gray leveling L2: ND N/A 10527-3-05 Corridor J-11 compound Layer 3: Light gray VCT L3: ND N/A Layer 4: Yellow/Black L4: ND N/A mastic Layer 5: White leveling L5: ND N/A compound Layer 1: Dark gray mastic L1: ND N/A (beneath 12"x12" light gray VCT) 10527-3- Layer 2: Yellow mastic L2: ND N/A 06QA Corridor 3-11 Layer 3: 9"x9" Light L3: 2% Chrysotile blue VAT (w/ white streaks) Layer 4: Black mastic L4: 3% Chrysotile on concrete Boy's Restroom ) Layer 1: White skim coat L1: ND L1: ND 10527-J-0714 w/ paint Layer 2: Plaster ceiling L2: ND L2: ND Layer 1: Yellow carpet L1: ND N/A mastic 10527-3-08 Math Classroom Layer 2: 9"x9" Tan VAT L2: 3% Chrysotile 3-7 (w/ brown and yellow streaks) Layer 3: Black mastic L3: ND N/A Layer 1: 1"x1" Brown L1: ND N/A 10527-J-09 Boy's Restroom 3- ceramic floor tile 14 Layer 2: Gray grout L2: ND N/A Layer 3: Gray mortar L3: ND N/A ehsi�► 62 EHS-International,Inc. i • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Beige paint on 4" L1: ND N/A white ceramic cove base 10527-J-10 Boy's Restroom J- Layer 2: Trace of brown L2: ND N/A 14 and yellow mastic Layer 3: Gray plaster on L3: ND N/a metal mesh 10527-J-11 Math ath Classroom 3- GWB w/ paper (mid wall) ND N/A Math Classroom J- Layer 1: White skim coat L1: ND N/A 10527-J-12 8 w/ paint Layer 2: Gray plaster L2: ND N/A Layer 1: JC w/ paint L1: ND N/A 10527-3-13 Math Classroom 3- Layer 2: JC w/ paint L2: ND N/A 8 Layer 3: GWB w/ paper L3: ND N/A (corner) 10527-J-14 Math ath Classroom 3- Gray g window glazing putty ND N/A 10527-J-15*4 Math Classroom J- Layer 1: 6" Red ceramic L1: ND N/A 9 window sill tile Layer 2: Dark gray grout L2: ND N/A Layer 3: Dark gray mortar L3:0.25% Chrysotile 10527-J-16 Attic Above Black flex duct ND N/A Storage J-1 10527-3-17 Attic Above Green pipe dope ND N/A Storage 3-1 (sprinkler fittings) Layer 1: Cream colored L1: ND N/A cove base mastic Layer 2: JC w/ paint L2: ND N/A 10527-J-18 Janitor J-4 Layer 3: Residual brown L3: ND N/A cove base mastic Layer 4: White skim coat L4: ND N/A w/ paint Layer 5: Gray Plaster L5: ND N/A BLOCK K Layer 1: Yellow/tan carpet L1: ND N/A mastic 10527-K-01 Math Office K-2 Layer 2: 9'x9" Red VAT L2. 3% Chrysotile Layer 3: Black mastic on L3: ND N/A concrete Layer 1: Yellow carpet L1: ND N/A 10527-K-02 F.L. Classroom K-9 mastic Layer 2: Gray leveling L2: ND N/A compound on concrete ehsi ENS-International.Inc. 63 i • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: White skim coat L1: ND N/A 10527-K-03 F.L. Classroom K-9 w/ paint Layer 2: Gray Plaster L2: ND N/A Layer 1: White skim coat L1: ND N/A 10527-K-04 Math Office K-2 w/ paint Layer 2: Gray Plaster L2: ND N/A 10527-K-05 Corridor K-5 Green pipe dope ND N/A (sprinkler fittings) 10527-K-06 Office K-7 Black speaker coating ND N/A w/paint Layer 1: White ACT w/ L1: ND N/A 10527-K-07 Computer K-3 small and large hole pattern Layer 2: Black glue dot L2: ND N/A Layer 1: Brown paper L1: ND N/A Layer 2: Black mastic L2: ND N/A 10527-K-08 Computer K-3 Layer 3: Brown paper L3: ND N/A (between wood beam and plaster wall) Layer 1: Brown cork L1: ND N/A Math Classroom K- board 10527-K-09 8 Layer 2: White styrofoam L2: ND N/A Layer 3: Tan glue dot L3: ND N/A w/paint Layer 1: JC w/ paint L1: ND N/A 10527-K-10 Office K-7 Layer 2: GWB w/ paper L2: ND N/A (corner) 10527-K-11 Office K-7 GWB (mid wall) ND N/A BLOCK L Layer 1: 12"x12" Light L1: ND N/A gray VCT (w/ white and 10527-L-01 Corridor L-6, North maroon streaks) Layer 2: Tan/yellow L2: ND N/A mastic on concrete Layer 1: 12"x12" Light L1: ND N/A Corridor L 6, gray VCT (w/ white and 10527-L-02 South maroon streaks) Layer 2: Tan/yellow L2: ND N/A mastic, on concrete Corridor L-6, Layer 1: 12"x12" Blue L1: ND N/A 10527-L-03VCT South Layer 2: Tan mastic L2: ND N/A ehsi.. 64 EHS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: 1'x1' White ACT L1: ND N/A (w/ pin hole and fissure 10527-L-04 Shop Classroom pattern) w/ paint L7 Layer 2: Brown glue dot L2: ND N/A Layer 3: JC L3: ND N/A Layer 4: GWB (at seam) L4: ND N/A Layer 1: 9"x9" Olive L1: 3% Chrysotile 10527-L-05 Ceramics Lab L-5 VAT Layer 2: Black mastic L2: 3% Chrysotile on concrete Layer 1: 9"x9" Light L1: 2% Chrysotile 10527-L-06 Ceramics Lab L-5 olive VAT Layer 2: Black mastic L2: 3% Chrysotile on concrete Layer 1: 12"x12" Light L1: ND N/A gray VCT (w/ white and 10527-L-07 Storage L-4 maroon streaks) Layer 2: Black mastic on L2: ND N/A concrete Layer 1: 2'x4' White SACT L1: ND N/A 10527-L-08 Corridor L-6 covering Layer 2: 2'x4' SACT L2: ND N/A Layer 1: 9"x9" Green L1: 3% Chrysotile 10527-L-09 Art Lab L-1 VAT (w/ beige streaks) Layer 2: Black mastic L2: 3% Chrysotile Layer 1: 4" Black cove L1: ND N/A base 10527-L-10 Art Lab L-1 Layer 2: Cream colored L2: ND N/A mastic Layer 3: JC L3: ND N/A 10527-L-11 Corridor L-6 Plaster (ceiling) ND N/A 10527-L-12 Corridor L-6 Plaster (ceiling) ND N/A 10527-L-13 Corridor L-6 Plaster (ceiling) ND N/A Layer 1: Skim coat L1: ND N/A 10527-L-14 Corridor L-6 w/paint Layer 2: Plaster L2: ND N/A Layer 1: Skim coat L1: ND N/A 10527-L-15 Corridor L-6 w/paint Layer 2: Plaster L2: ND N/A Layer 1: Skim coat L1: ND N/A 10527-L-16 Corridor L-6 w/paint Layer 2: Plaster L2: ND N/A • ehsi..6 EHS-Intemational,Inc. 65 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: JC L1: 0.5% N/A 10527-L-17*5 Corridor L-6 Layer 2: GWB (mid L2: ND N/A ceiling) Layer 1: 1'x1' White ACT L1: ND N/A (w/ pin hole and fissure 10527-L-18 Corridor L-6 pattern) w/ paint Layer 2: Brown glue dot L2: ND N/A Layer 3: GWB (at seam) L3: ND N/A Layer 1: 1'x1' White ACT L1: ND N/A cover 10527-L- Art Lab L-1 Layer 2: 1'x1' Brown ACT L2: ND N/A 19QA interior Layer 3: Brown vapor L3: ND N/A barrier w/ black mastic 2'x4' White SACT (w/ 10527-L-20 Art Lab L-1 worm track and pin hole ND N/A pattern) Layer 1: 4"Tan cove base L1: ND N/A 10527-L-21 Storage L-3 Layer 2: Cream colored L2: ND N/A mastic Layer 3: Brown mastic L3: ND N/A Layer 1: 1'x1' White ACT L1: ND N/A w/ small pin hole covering 10527-L-22 Office L-8 Layer 2: 1'x1' Brown ACT L2: ND N/A interior Layer 3: Brown glue dot Layer 1: 4"Tan CB L1: ND N/A Layer 2: Cream colored L2: ND N/A 10527-L-23 Corridor L-6 mastic Layer 3: Black cove base L3: ND N/A Layer 4: Brown mastic L4: ND N/A 10527-L-24 Shop Classroom L- Layer 1: Blue/gray carpet L1: ND N/A 7 Layer 2: Tan mastic L1: ND N/A Layer 1: Blue/gray carpet Ll: ND N/A Layer 2: Tan mastic L2: ND N/A Layer 3: White leveling L3: ND N/A 10527-L-25 Office L-8 compound Layer 4: 9"x9" Red VAT L4: 3% Chrysotile Layer 5: Black mastic on concrete L5: 3% Chrysotile ehsi 66 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Red sheet vinyl L1: ND N/A 10527-L- Layer 2: Black asphaltic L2: ND N/A 26QAX Metal Shop backing Layer 3: Black mastic L3: 4% Chrysotile on concrete Layer 1: Red sheet vinyl L1: ND N/A Layer 2: Black asphaltic L2: ND N/A 10527-L-27 Wood Shop Area backing Layer 3: Black mastic L3: 3% Chrysotile on concrete Wood Shop Layer 1: JC L1: ND N/A 10527-L-28 Layer 2: GWB w/ paper L2: ND N/A Mezzanine Storage (ceiling seam) 10527-L-29 Wood Shop GWB w/ paper (mid ND N/A Mezzanine Storage ceiling) 10527-L-30 Auto Shop L-15 GWB w/ paper and paint ND N/A (mid ceiling) 10527-L-31 Auto Shop L-15 Black/Gray expansion ND N/A joint sealant Layer 1: White paint on L1: ND N/A 10527-L-32 Corridor L-6, red paint South Layer 2: Beige wall L2: ND N/A texturing Layer 1: White paint on L1: ND N/A 10527-L-33 Corridor L-6, North red paint Layer 2: Beige wall L2: ND N/A texturing 10527-L-34 Auto Shop L15 Gray CMU mortar w/ paint ND N/A 10527-L-35 Corridor L-6 Layer 1: Red brick L1: ND N/A Layer 2: Gray mortar L2: ND N/A Layer 1: 1"xl" Off-white L1: ND N/A 10527-L-36 Corridor L-6 ceramic wall tile L2: ND N/A Layer 2: Beige grout L3: ND N/A Layer 3: Dark gray mortar Layer 1: JC w/ paint L1: ND N/A 10527-L-37 Storage L-3 Layer 2: GWB w/ paint L2: ND N/A and paper (mid wall) 10527-L-38 Ceramics Lab L-5 GWB w/ paint and paper ND N/A Layer 1: JC w/ paint and L1: 0.25% Chrysotile 10527-L-39*5 Art Lab L-1 paper Layer 2: GWB w/ paper L2: ND N/A 10527-L-40 Art Lab L-1 Gray window glazing putty ND N/A w/paint ehsi EHS-International,Inc. 67 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 • July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Corridor L-6 Gray caulking w/paint 10527-L-41 South around metal seismic 3% Chrysotile wall bracket Layer 1: Beige soft L1; ND N/A 10527-L-42 Corridor L-6 caulking w/paint Layer 2: Beige hard L2: ND N/A caulking BLOCK M Layer 1: 9"x9" Olive L1: 3% Chrysotile colored VAT (w/ pink 10527-M-01 Choral M-26 and beige streaks) Layer 2: Black mastic L2: 2% Chrysotile on concrete Layer 1: 8" Black cove L1: ND N/A 10527-M-02 Choral M-26 base Layer 2: Brown mastic L2: ND N/A Layer 1: 12"x12" Light L1: ND N/A gray VCT (w/ white and 10527-M-03 Corridor M-12 gray streaks) Layer 2: Yellow mastic L2: ND N/A Layer 3: Gray leveling L3: ND N/A compound Layer 1: 12"x12" Blue L1: ND N/A VCT 10527-M-04 Corridor M-1 Layer 2: Yellow mastic L2: ND N/A Layer 3: Trace black L3: 2% Chrysotile mastic on concrete Layer 1: 4"Tan cove base L1: ND N/A 10527-M-05 Corridor M-12 Layer 2: Cream colored L2: ND N/A mastic Layer 3: Brown mastic L3: ND N/A Layer 1: 4" Black cove L1: ND N/A base 10527-M-06 Choral M-26 Layer 2: Cream colored L2: ND N/A mastic Layer 3: Brown mastic L3: ND N/A Layer 1: 1'x1' White ACT L1: ND N/A w/ pin hole pattern 10527-M-07 Storage M-34 Layer 2: Brown glue dot L2: ND N/A Layer 3: GWB w/ paper, L3: ND N/A ceiling ehs .. 68 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: l'x1' White ACT L1: ND N/A w/ pin hole pattern L2: ND N/A Layer 2: Brown glue dot L3: ND N/A 10527-M-08 Entry M-18 Layer 3: Silver seam tape Layer 4: Gray seam tape L4: ND N/A mastic Layer 5: GWB w/ paper L5: ND N/A (ceiling seam) Layer 1: Blue/gray carpet L1: ND N/A Layer 2: Tan mastic L2: ND N/A Band Room- Layer 3: 9"x9" Olive L3: 3% Chrysotile 10527-M-09 Practice 3, M-29 colored VAT (w/ pink and beige streaks) Layer 4: Black mastic L4: 2% Chrysotile on concrete Layer 1: Blue/gray carpet L1: ND N/A 10527-M-10 Band Room M-17 Layer 2: Tan mastic L2: ND N/A Layer 3: Trace black L3: ND N/A mastic L1: ND N/A Layer 1: Blue/gray carpet 10527-M-11 Band Room- Layer 2: Tan mastic L2: ND N/A Practice 2, M-15 Layer 3: 9"x9" Red VAT L3: 3% Chrysotile Layer 4: Black mastic L4: ND N/A Layer 1: 12"x12" Light L1: ND N/A Photography Lab gray VCT (w/ maroon and 10527-M-12 M-38 white streaks) Layer 2: Black mastic L2. 3% Chrysotile on concrete Layer 1: 1"xl" Blue L1: ND N/A 10527-M-13 Men's Restroom ceramic floor tile M-3 Layer 2: Gray grout L2: ND N/A Layer 3: White mortar L3: ND N/A Layer 1: 1"x1" Pink L1: ND N/A 10527-M-14 Women Restroom ceramic floor tile M-4 Layer 2: Gray grout L2: ND N/A Layer 3: White mortar L3: ND N/A ehsi EHS-International,Inc. 69 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 • July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Yellow VAT L1: 2% Chrysotile Science (w/ brown and black 10527-M-15 streaks) Classroom M-11 Layer 2: Black mastic L2: 3% Chrysotile on concrete Layer 1: 12"x12" Light L1: ND N/A blue VCT (w/ blue and 10527-M-16 Chemistry Lab M-6 white streaks) Layer 2: Tan mastic L2: ND N/A Layer 3: Gray VCT L3: ND N/A Layer 4: Black mastic L4: ND N/A Layer 1: 9"x9" Olive L1: 3% Chrysotile 10527-M-17 Physics Lab M-7 colored VAT (w/ black and beige streaks) Layer 2: Black mastic L2: ND N/A 10527-M- Layer 1: White skim coat L1: ND N/A 18QA Mechanical M-3 w/ paint Layer 2: Plaster (ceiling) L2: ND N/A Layer 1: White skim coat L1: ND N/A 10527-M-19*6 Storage M-2 w/ paint Layer 2: Plaster (ceiling) L2: .75% Chrysotile Layer 1: White skim coat L1: ND N/A 10527-M-20*6 Band M-17 w/ paint Layer 2: Plaster (mid wall) L2: 0.5% Chrysotile Layer 1: White skim coat L1: ND N/A 10527-M-21*6 Storage M-2 w/ paint Layer 2: Plaster (mid wall) L2: 0.75% Chrysotile Layer 1: White paint L1: ND N/A L2: ND N/A Layer 2: Beige wall 10527-M-22 Corridor M-1 texturing L3: ND N/A Layer 3: Red paint L4: ND N/A Layer 4: Trace CMU debris Layer 1: White paint L1: ND N/A Corridor M-12, Layer 2: Beige wall L2: ND N/A 10527-M-23 texturing L3: ND N/A South Layer 3: Red paint Layer 4: Trace CMU debris L4: ND N/A Layer 1: White paint L1: ND N/A L2: ND N/A Corridor M-12, Layer 2: Beige wall 10527-M-24 texturing L3: ND N/A Middle Layer 3: Red paint Layer 4: Trace CMU debris L4: ND N/A ehsi4 70 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: JC w/ beige paint L1: ND N/A 10527-M-25 Corridor M-6 Layer 2: GWB w/ paper (corner wall) L2: ND N/A 10527-M-26 Band Room M-17 GWB w/ paint and paper ND N/A (mid wall) Layer 1: JC w/ paper L1: ND N/A 10527-M-27 Corridor M-12 Layer 2: GWB w/ paper L2: ND N/A (ceiling edge) 10527-M-28 Corridor M-12 GWB w/ paper (mid wall) ND N/A 10527-M-29 Mechanical M-5 Tan pipe dope ND N/A Layer 1: 4"x4" Beige L1: ND N/A Boy's Restroom M ceramic wall tile 10527-M-303 Layer 2: Beige grout L2: ND N/A Layer 3: Tan mastic L3: ND N/A Layer 4: Gray mortar L4: ND N/A Layer 1: Gray door frame L1: ND N/A 10527-M-31 Corridor M-12 caulking Layer 2: White door frame L2: ND N/A caulking Layer 1: Beige paint L1: ND N/A 10527-M-32 Entry to M-18 Layer 2: Red wall panel L2: ND N/A Layer 3: White wall panel L3: ND N/A 10527-M-33 Instrument Gray sink undercoat ND N/A Storage M-19 Layer 1: 1'z1' White ACT L1: ND N/A 10527-M- w/ large and small pin 34QA Band M-17 hole Layer 2: Brown glue dot L2: ND N/A on plaster wall TUNNELS Layer 1: Gray/Off- L1: 8% Chrysotile white TSI debris 10527-T-01. Utility Tunnel Layer 2: Pink material TSI L2: ND N/A L/M-NW End debris Layer 3: White foamy L3: ND N/A Material 10527-T-02 Utility Tunnel L/M- Black/brown asphaltic N-S Intersection paper debris ND N/A Utility Tunnel Army green/gray 10527-T-03 L/M, At Tunnel mastic w/ debris on 3% Chrysotile Hatch cable bracket ehsi• EHS-International,Inc, 71 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Gray fibrous L1: 60% Chrysotile Utility Tunnel material/paper 10527-T- A/B Boiler Room Layer 2: Black asphaltic L2: 22% Chrysotile 04QAx Tunnel vapor barrier, between concrete and wood forms Utility Tunnel A/B Layer 1: Debris L1: ND N/A 10527-05 Boiler Room Layer 2: GWB w/paper L2: ND N/A Tunnel Utility Tunnel Layer 1: Concrete debris L1: ND N/A 10527-T-06 A/B Boiler Room Layer 2: TSI on L2: 56% Chrysotile Tunnel abandoned pipe (8" OD) Utility Tunnel A/B Layer 1: Black asphaltic L1: ND N/A 10527-T-07 Boiler Room pipe coating Tunnel Layer 2: Gray/white L2: ND N/A tunnel debris Block G Crawl Layer 1: 3C L1: 3% Chrysotile 10527-T-08 Space Layer 2: GWB (access L2: ND N/A door) CONCRETE SLAB CORING Layer 1: Grout and L1: ND N/A 10527-62513- Block A2-Girls concrete debris 01 Locker Room Layer 2: Trace black L2: ND N/A mastic Layer 1: Black plastic L1: ND N/A 10527-62513- Block G-Janitor vapor barrier w/ fibrous material 02 Closet Layer 2: Brown paper L2: ND N/A vapor barrier EXTERIOR 10527-EXT- Industrial Art, White caulking w/paint 2% Chrysotile 01 Exterior on steel columns Industrial Art, Brown high voltage 10527-EXT-02 Exterior conduit penetration ND N/A sealant 10527-EXT- Industrial Art, Gray door frame 03QA Exterior caulking w/paint 2% Chrysotile (8x10 roll-up door) Auto Shop, Gray window glazing putty ND N/A 10527-EXT-04 Exterior (on 6'x10' roll-up door ) 10527-EXT-05 Auto Shop, White door trim caulking ND N/A Exterior (3'x8' roll up door) ehsi 72 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Tan/gray door frame 10527-EXT- Block F, Exterior caulking w/paint 2% Chrysotile 06 (8'x14'on double doors) 10527-EXT-07 Block F, Exterior Beige Shotcreteirl ND N/A West Side Layer 1: Tan window L1: 2% Chrysotile 10527-EXT- Block F, Exterior frame caulking(4'x18') 08 West Side Layer 2: Brown wood debris L2: ND N/A 10527-EXT-09 Block F, Exterior Graywindow glazing West Side 9 9 putty ND N/A Layer 1: Black asphaltic L1: ND N/A Block F, Exterior paper (behind wood 10527-EXT-10 column) West Side Layer 2: Brown wood L2: ND N/A debris 10527-EXT-11 Block K, Exterior Beige shotcrete ND N/A 10527-EXT-12 Block H, Exterior Beige shotcrete ND N/A 10527-EXT-13 Block F, Exterior Beige shotcrete ND N/A West Side 10527-EXT-14 Block J, Exterior Beige shotcrete ND N/A South Side 10527-EXT-15 Block E, Exterior Beige shotcrete ND N/A East Side 10527-EXT-16 Block E, Exterior Beige shotcrete ND N/A East Side Block E, 2001 10527-EXT-17 addition, Exterior Beige EFIS w/paint ND N/A East Side Block B, 2001 10527-EXT-18 addition, Exterior Beige EFIS w/paint ND N/A East Side Block B, 2001 10527-EXT-19 addition, Exterior Beige EFIS w/ yellow/blue ND N/A East Side paint Layer 1: Tan/beige EFIS L1: ND N/A 10527-EXT-20 Block A, Exterior Layer 2: White styrofoam L2: ND N/A insulation 10527-EXT-21 Block A, Exterior Tan/beige EFIS w/paint ND N/A East Side Block A Exterior Layer 1: Tan/beige EFIS Li: ND N/A 10527-EXT-22 North Side Layer 2: Beige building L2: ND N/A seam caulking ehsi ENS-International.Inc. 73 i i Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS 10527-EXT-23 Block A, Exterior Tan/beige EFIS ND N/A North Side 10527-EXT-24 Block A, Exterior Tan/beige EFIS ND N/A West Side 10527-EXT-25 Block A, Exterior Tan/beige EFIS ND N/A West Side Block B, Exterior Layer 1: Tan/beige EFIS L1: ND N/A 10527-EXT-26 West Side Layer 2: Beige building L2: ND N/A seam caulking Central Layer 1: Gray paper L1: ND N/A 10527-EXT-27 Greenhouse Layer 2: Beige caulking L2: ND N/A (on greenhouse frame) 10527-EXT- Block M, Exterior Gray window frame 2% Chrysotile 28 caulking (3'x5') 10527-EXT-29 Block M, Exterior Beige EFIS w/paint ND N/A East Wall 10527-EXT-30 Block M, Exterior Beige EFIS w/paint ND N/A East Wall 10527-EXT-31 Block M, Exterior Beige EFIS w/paint ND N/A East Wall Block K, Exterior Layer 1: JC w/ paper L1: ND N/A 10527-EXT-32 Covered Walkway Layer 2: GWB w/ paper L2: ND N/A West Side (soffit seam) Block K, F, G, H Layer 1: JC w/ paint L1: ND N/A 10527-EXT-33 and K, Exterior Layer 2: GWB w/ paper L2: ND N/A Covered Walkway (soffit seam) Block E, F, G, H GWB w/ paint and paper 10527-EXT-34 and K, Exterior ND N/A (mid soffit) Covered Walkway 10527-EXT- Block E, F, G, H Layer 1: JC w/ paint L1: ND N/A 35QA and K, Exterior Layer 2: GWB w/ paper L2: ND N/A Covered Walkway (mid-soffit) Layer 1: JC w/ fibrous L1: ND N/A 10527-EXT-36 Block D, Exterior material and paint Layer 2: GWB w/ paper L2: ND N/A (soffit seam) 10527-EXT-37 Block D, Exterior GWB w/ Ppp and masticaint(mid soffit)andaer ND N/A 10527-EXT-38 Block D, Exterior GWB w/ paint and paper ND N/A and mastic (mid soffit) ehsi 74 ENS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLINGAND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Black asphaltic L1: ND N/A felt 10527-EXT- Block C, Exterior Layer 2: Black asphaltic L2: 2% Chrysotile 39 tar Layer 3: Concrete debris L3: ND N/A (on foundation wall) Layer 1: Black asphaltic L1: ND N/A felt 10527-EXT- Block C, Exterior Layer 2: Black asphaltic L2: 3% Chrysotile 40 tar Layer 3: Concrete debris L3: ND N/A (on foundation wall) Layer 1: Black asphaltic L1: ND N/A felt 10527-EXT- Block C, Exterior Layer 2: Black asphaltic L2: 3% Chrysotile 41 tar Layer 3: Concrete debris L3: ND N/A (on foundation wall) ROOF Layer 1: Black asphaltic L1: ND N/A 3-tab shingle Layer 2: Black asphaltic L2: ND N/A Community Pool vapor barrier 10527-R-01 Building, South Layer 3: Black asphaltic L3: ND N/A Side, Low Roof vapor barrier Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Black asphaltic L5: ND N/A vapor barrier (on wood) Layer 1: Black asphaltic Li: ND N/A 3-tab shingle Layer 2: Black asphaltic L2: ND N/A vapor barrier 10527-R-02 Community Pool, Layer 3: Black asphaltic L3: ND N/A Central High Roof vapor barrier Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Black asphaltic L5: ND N/A vapor barrier (on wood) Layer 1: Black asphaltic Li: ND N/A 10527-R-03 Community Pool, 3-tab shingle NW Side Low Roof Layer 2:Black asphaltic L2: ND N/A vapor barrier (on wood) ehsi♦4 �s EHS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Black asphaltic Li: ND N/A built-up roofing w/ sand Layer 2: Black asphaltic L2: ND N/A built-up roofing w/ sand Layer 3: Black asphaltic L3: ND N/A built-up roofing w/ sand Layer 4: Brown insulation L4: ND N/A Layer 5: Black asphaltic L5: ND N/A vapor barrier Layer 6: Yellow foam L6: ND N/A insulation Layer 7: Black asphaltic L7: ND N/A Community Pool, vapor barrier 10527-R-04 Central Flat Roof, Layer 8: White foam L8: ND N/A East insulation Layer 9: Black asphaltic L9: ND N/A vapor barrier Layer 10: Black asphaltic L10: ND N/A vapor barrier Layer 11: Yellow foam L11: ND N/A insulation Layer 12: Black asphaltic L12: ND N/A vapor barrier Layer 13: Black asphaltic L13: ND N/A vapor barrier Layer 14: White foam L14: ND N/A insulation Layer 1: Black asphaltic L1: ND N/A built-up roofing w/ sand Layer 2: Black asphaltic L2: ND N/A built-up roofing w/ sand Layer 3: Black asphaltic L3: ND N/A built-up roofing w/ sand Layer 4: Brown insulation L4: ND N/A Layer 5: Black asphaltic L5: ND N/A Community Pool, vapor barrier 10527-R-05 Central Flat Roof, Layer 6: Yellow foam L6: ND N/A West insulation Layer 7: Black asphaltic L7: ND N/A vapor barrier Layer 8: White foam L8: ND N/A insulation Layer 9: Black asphaltic L9: ND N/A vapor barrier Layer 10: Black asphaltic L10: ND N/A vapor barrier ehsi.. 76 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULKSAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGHSCHOOL SAMPLES AMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 11: Yellow foam L11: ND N/A insulation Layer 12: Black asphaltic L12: ND N/A vapor barrier Layer 13: Black asphaltic L13: ND N/A vapor barrier Layer 14: White foam L14: ND N/A insulation Community Pool, Black asphaltic sealant on Central Flat Roof, ND N/A 10527-R-06 West roof vent Community Pool, Black asphaltic tar on roof Central Flat Roof, ND N/A 10527-R-07 West flashing Community Pool, Gray seam sealant w/ Central Flat Roof, paint and debris on roof ND N/A 10527-R-08 West flashing Community Pool, Layer 1: Clear window L1: ND N/A Central Flat Roof, frame caulking WestLayer 2: Brown window L2: ND N/A i0527-R-09frame caulking w/paint Community Pool, Black caulking w/paint Central Flat Roof, around 14" exhaust fan ND N/A 10527-R-10 West Community Pool, Layer 1: Black caulking L1: ND N/A Central Flat Roof, Layer 2: Beige caulking L2: ND N/A 10527-R-11 West around wood panels Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built up roofing Block A Roof, NW Layer 3: Black asphaltic L3: ND N/A 10527-R-12 Low Roof, West vapor barrier Side Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Brown paper (on L5: ND N/A wood) Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Block A Roof, NW Layer 3: Black asphaltic L3: ND N/A 10527-R-13 Low Roof, East vapor barrier Side Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Brown paper (on L5: ND N/A wood) ehsi 4 77 ENS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS • Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A Block A, NW Low built-up roofing w/ sand 10527-R-14 Roof, N. Parapet Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Black asphaltic L4: ND N/A vapor barrier (on wood) Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing w/ sand Block A Roof, N. Layer 3: Black asphaltic L3: ND N/A 10527-R-15 Side High Roof. W. vapor barrier Side Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Brown paper (on L5: ND N/A wood) Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing w/ sand Block A Roof, N. Layer 3: Black asphaltic L3: ND N/A 10527-R-16 Side High Roof. E. vapor barrier Side Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Brown paper (on L5: ND N/A wood) Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing w/ sand Block A Roof, N. Layer 3: Black asphaltic L3: ND N/A 10527-R-17 Side High Roof. E. vapor barrier Side, Parapet Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Beige paint (on L5: ND N/A concrete) ?s"/., ENS-International,Inc. 78 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Black asphaltic L1: ND N/A built-up roofing L2: ND N/A Layer 2: Brown insulation Layer 3: Black asphaltic L3: ND N/A vapor barrier Block A Roof, Layer 4: Yellow foam L4: ND N/A Central Dome insulation Shaped Roof W. Layer 5: Black asphaltic L5: ND N/A Side vapor barrier Layer 6: Black asphaltic L6: ND N/A tar Layer 7: Yellow foam L7: ND N/A insulation Layer 8: White paper (on L8: ND N/A 10527-R-18 wood) Layer 1: Black asphaltic L1: ND N/A built-up roofing Layer 2: Brown insulation L2: ND N/A Layer 3: Black asphaltic L3: ND N/A vapor barrier Block A Roof, Layer 4: Yellow foam L4: ND N/A Central Dome insulation 10527-R-19 Shaped Roof, Layer 5: Black asphaltic L5: ND N/A Center vapor barrier Layer 6: Black asphaltic L6: ND N/A tar Layer 7: Yellow foam L7: ND N/A insulation Layer 8: White paper (on L8: ND N/A wood) Layer 1: Black asphaltic L1: ND N/A built-up roofing Layer 2: Brown insulation L2: ND N/A Layer 3: Black asphaltic L3: ND N/A Block A Roof, vapor barrier Central Dome Layer 4: Yellow foam L4: ND N/A 10527-R-20 Shaped Roof E. insulation Side Layer 5: Black asphaltic L5: ND N/A vapor barrier Layer 6: Black asphaltic L6: ND N/A tar Layer 7: Yellow foam L7: ND N/A insulation (on wood) ehsi..� EHS-International,Inc. 79 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 r July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % , ASBESTOS Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing L3: ND N/A Layer 3: Brown insulation Layer 4: Black asphaltic L4: ND N/A Block A Roof, W. vapor barrier Side Highest Roof, Layer 5: Yellow foam L5: ND N/A N. Side insulation Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Black asphaltic L7: ND N/A tar Layer 8: White paper, on L8: ND N/A 10527-R-21 wood Layer 1: Silver coat Li: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 4: Black asphaltic L4: ND N/A Block A Roof, W. vapor barrier 10527-R-22 Side Highest Roof, Layer 5: Yellow foam L5: ND N/A S. Side insulation Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Black asphaltic L7: ND N/A tar Layer 8: White paper (on L8: ND N/A wood) Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing N/A Layer 3: Brown insulation L3: ND Layer 4: Black asphaltic L4: ND N/A Block A Roof, E. vapor barrier 10527-R-23 Side Highest Roof, Layer 5: Yellow foam L5: ND N/A S. Side, over insulation Corridor Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Black asphaltic L7: ND N/A tar Layer 8: White paper (on L8: ND N/A wood) efts'/.. 80 EH S-International.Inc. t • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 4: Black asphaltic L4: ND N/A Block A Roof, E. vapor barrier 10527-R-24 Side Highest Roof, Layer 5: Yellow foam L5: ND N/A N. Side, over insulation Corridor Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Black asphaltic L7: ND N/A tar Layer 8: White paper, on L8: ND N/A wood Block A Roof N. Brown/gray caulking 10527-R-25 Side High Roof w/paint on parapet ND N/A flashing Layer 1: Silver paint L1: 2% Chrysotile 10527-R-26 Block A Roof, N. Layer 2: Black asphaltic L2: 4% Chrysotile Side High Roof tar(at roof vent base) Layer 1: Silver Coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing 10527-R-27 Block A Roof, N. Layer 3: Black asphaltic L3: ND N/A Side High Roof tar Layer 4: Black asphaltic L4: ND N/A vapor barrier, at roof curb (roof vent base) Layer 1: Silver Coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A Block B Roof, W. built-up roofing 10527-R-28 Side Lower Roof Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Brown paper L4: ND N/A vapor barrier (on wood) 10527-R-29 Block B Roof, W. Gray duct seam sealant ND N/A Side Lower Roof ehsi EHS-International,Inc. 81 • • . ' Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Silver Coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Layer 3: Black asphaltic L3: ND N/A tar Layer 4: Brown insulation L4: ND N/A Block B Roof, Layer 5: Black asphaltic L5: ND N/A 10527-R-30 Central High Roof, vapor barrier W. Layer 6:Yellow foam L6: ND N/A insulation Layer 7: Black asphaltic L7: ND N/A vapor barrier Layer 8: Yellow foam L8: ND N/A insulation Layer 9: White paper L9: ND N/A Layer 1: Silver coat L1: ND N/A Block B Roof, Layer 2: Black asphaltic L2: ND N/A 10527-R-31 Central High Roof, built-up roofing E Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Brown paper L4: ND N/A Block B Roof, Layer 1: Black asphaltic L1: ND N/A 10527-R-32 Central Low Roof built-up roofing w/ sand Layer 2: Brown insulation L2: ND N/A Layer 1; Black asphaltic L1: ND N/A built-up roofing w/ sand Layer 2: Brown insulation L2: ND N/A Layer 3: Black asphaltic L3: ND N/A tar Block B Roof, E. Layer 4: Brown insulation L4: ND N/A 10527-R-33 Side High Roof, S. Layer 5: Yellow foam L5: ND N/A Side insulation Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Yellow foam L7: ND N/A insulation Layer 8: Gray paper vapor L8: ND N/A barrier (on wood) ehsi i. 82 EHS-International,Inc. Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1; Black asphaltic L1: ND N/A built-up roofing w/ sand Layer 2: Brown insulation L2: ND N/A Layer 3: Black asphaltic L3: ND N/A tar Block B Roof, E. Layer 4: Brown insulation L4: ND N/A 10527-R-34 Side High Roof, N. Layer 5: Yellow foam L5: ND N/A Side insulation Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Yellow foam L7: ND N/A insulation Layer 8: Gray paper vapor L8: ND N/A barrier (on wood) Block B Roof, Tan/beige seam caulking 10527-R-35 between Block w/paint ND N/A A&B 10527-R-36 Block B Roof Black asphaltic tar w/paint ND N/A Central Low Roof on metal flashing 10527-R-37 Block B Roof Tan air vent frame ND N/A Central Low Roof caulking w/paint 10527-R-38 Block C Roof, S. Black sealant w/paint ND N/A Side around brick wall infill 10527-R-39 Block C Roof, S. Gray/tan sealant w/paint ND N/A Side around brick wall infill 10527-R-40 Block C Roof, S. Gray/tan sealant on metal ND N/A Side roof flashing Layer 1: Black asphaltic L1: ND N/A 3-tab shingle w/ sand 10527-R-41 Block C Roof, N. Layer 2: Black asphaltic L2: ND N/A Side vapor barrier Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 1: Black asphaltic L1: ND N/A 3-tab shingle w/ sand Layer 2: Black asphaltic L2: ND N/A 10527-R-42 Block C Roof, vapor barrier Center Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Black asphaltic L4: ND N/A vapor barrier ehSin EHS-International.Inc. 83 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % _ ASBESTOS Layer 1: Black asphaltic L1: ND N/A 3-tab shingle w/ sand 10527-R-43 Block C Roof, S. Layer 2: Black asphaltic L2: ND N/A Side vapor barrier Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 1: White membrane L1: ND N/A Block B Entrance roofing 10527-R-44 Awning Layer 2: Black asphaltic L2: ND N/A backing Layer 3: Brown insulation L3: ND N/A Layer 1: White membrane L1: ND N/A Block B Entrance roofing 10527-R-45 Awning Layer 2: Black asphaltic L2: ND N/A backing Layer 3: Brown insulation L3: ND N/A Layer 1: Silver coat L1: 2% Chrysotile Layer 2: Black asphaltic L2: 4% Chrysotile built-up roofing Block C Roof, Layer 3: Black asphaltic 10527-R-46 Flat Roof, S. Side vapor barrier L3: ND N/A Layer 4: Black asphaltic vapor barrier L4: ND N/A Layer 5: Brown paper vapor barrier L5: ND N/A Layer 1: Silver coat L1: 2% Chrysotile Layer 2: Black asphaltic L2: 4% Chrysotile built-up roofing Block C Roof, Layer 3: Black asphaltic 10527-R-47 Flat Roof, N. vapor barrier L3: ND N/A Side Layer 4: Black asphaltic vapor barrier L4: ND N/A Layer 5: Brown paper vapor barrier L5: ND N/A ehsi. 84 EHS-International,Inc. • 410 Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % , ASBESTOS Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing L3: ND N/A Layer 3: Brown insulation Layer 4: Black asphaltic vapor barrier L4: ND N/A Roof Over Corridor Layer 5: Black asphaltic L5: ND N/A 10527-R-48 between Block C vapor barrier and D Layer 6: Yellow foam L6: ND N/A insulation Layer 7: Black asphaltic vapor barrier L7: ND N/A Layer 8: Black asphaltic L8: ND N/A vapor barrier Layer 9: Yellow foam L9: ND N/A insulation Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing L3: ND N/A Layer 3: Brown insulation Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Black asphaltic L5: ND N/A vapor barrier 10527-R-49 Block D Roof, N. Layer 6: Yellow foam L6: ND N/A Side insulation Layer 7: Black asphaltic L7: ND N/A vapor barrier Layer 8: Black asphaltic L8: ND N/A vapor barrier Layer 9: Yellow foam L9: ND N/A insulation Layer 10: White paper L10: ND N/A vapor barrier alai 6 EHS-International. 85 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Black asphaltic L5: ND N/A vapor barrier 10527-R-50 Block D Roof, S. Layer 6: Yellow foam L6: ND N/A Side insulation Layer 7: Black asphaltic L7: ND N/A vapor barrier Layer 8: Black asphaltic L8: ND N/A vapor barrier Layer 9: Yellow foam L9: ND N/A insulation Layer 10: White paper L10: ND N/A vapor barrier Layer 1: Silver Coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Black asphaltic L5: ND N/A 10527-R-51 Block D Roof, E. vapor barrier Side Layer 6: Yellow foam L6: ND N/A insulation Layer 7: Black asphaltic L7: ND N/A vapor barrier Layer 8: Black asphaltic L8: ND N/A vapor barrier Layer 9: Yellow foam L9: ND N/A insulation Layer 1: Black asphaltic L1: ND N/A 3-tab roofing w/ sand 10527-R-52 Block D Roof, E, Layer 2: Black asphaltic L2: ND N/A Mansard vapor barrier Layer 3: Black asphaltic L3: ND N/A vapor barrier Block D Roof, E. Black asphaltic 10527-R-53 Side penetration sealant on ND N/A • roof anchor e s ►. 86 EHS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Block D Roof, N. Black asphaltic sealant 10527-R-54 Side on building wall 4% Chrysotile flashing Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A 10527-R-55 Block E Roof, W. built-up roofing L3: ND N/A Side Layer 3: Brown insulation Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A 10527-R-56 Block E Roof, E. built-up roofing L3: ND N/A Side Layer 3: Brown insulation Layer 4: Black asphaltic vapor barrier L4: ND N/A Layer 1: Black asphaltic L1: ND N/A built-up roofing w/ sand Layer 2: Brown insulation L2: ND N/A Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Black asphaltic L4: ND N/A Block E Roof, New tar 10527-R-57 Addition, N. Side Layer 5: Yellow foam L5: ND N/A insulation Layer 6: Black/gray L6: ND N/A asphaltic tar Layer 7: Yellow foam L7: ND N/A insulation Layer 8: Black/gray L8: ND N/A asphaltic tar Layer 1: Black asphaltic L1: ND N/A built-up roofing w/ sand Layer 2: Brown insulation L2: ND N/A Layer 3: Black asphaltic L3: ND N/A vapor barrier Block E Roof, New Layer 4: Black asphaltic L4: ND N/A 10527-R-58 tar Addition, S. Side Layer 5: Yellow foam L5: ND N/A insulation Layer 6: Black/gray L6: ND N/A asphaltic tar Layer 7: Yellow foam L7: ND N/A insulation e si4 ENS-Intemational,Inc. 87 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 8: Black/gray L8: ND N/A asphaltic tar Block E Roof, New Layer 1: Black asphaltic Li: ND N/A 10527-R-59 Addition, over S. 3-tab roofing w/ sand Main Entrance Layer 2: Black asphaltic L2: ND N/A vapor barrier Block E Roof, New Black asphaltic vapor 10527-R-60 Addition, over S. barrier behind wood siding ND N/A Main Entrance Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing 10527-R-61 Block F Roof, E. Layer 3: Brown insulation L3: ND N/A Side Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 5: Black asphaltic L5: ND N/A tar Layer 1: Silver coat L1: ND N/A 10527-R-62 Block F Roof, Layer 2: Black asphaltic L2: ND N/A Center built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 1: Silver coat L1: ND N/A 10527-R-63 Block F Roof, W. Layer 2: Black asphaltic L2: ND N/A Side built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 1: Silver coat L1: ND N/A 10527-R-64 Block J Roof, Layer 2: Black asphaltic L2: ND N/A Center built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 1: Silver coat Li: ND N/A 10527-R-65 Block K Roof, Layer 2: Black asphaltic L2: ND N/A Center built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 1: Black asphaltic L1: ND N/A 3-tab roofing w/ sand Layer 2: Black asphaltic L2: ND N/A 10527-R-66 Block F, S. Side vapor barrier Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Black asphaltic L4: ND N/A vapor barrier ehsi•s 88 EHS-International,Inc. • ! Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Black asphaltic L1: ND N/A 3-tab roofing w/ sand Layer 2: Black asphaltic L2: ND N/A 10527-R-67 Block J Roof, S. vapor barrier Side Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 1: Black asphaltic L1: ND N/A 3-tab roofing w/ sand Layer 2: Black asphaltic L2: ND N/A 10527-R-68 Block K Roof, S. vapor barrier Side Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 1: Silver Coat L1: ND N/A Block F Roof Layer 2: Black asphaltic L2: ND N/A 10527-R-69 Center (Roof Curb) built-up roofing Layer 3: Black asphaltic L3: ND N/A vapor barrier 10527-R-70 Block F Roof, Gray/silver caulking ND N/A Central Area around roof vent 10527-R-71 Block F Roof, Gray seam caulking w/ ND N/A Central Area paint Layer 1: Silver coat L1: ND N/A Block G Roof, W. Layer 2: Black asphaltic L2: ND N/A 10527-R-72 Side built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 1: Silver coat L1: ND N/A Block G Roof, E. Layer 2: Black asphaltic L2: ND N/A 10527-R-73 Side built-up roofing Layer 3: Brown insulation L3: ND N/A 10527-R-74 Block G Roof, E. Black penetration sealant ND N/A Side on lead vent pipe Layer 1: Black asphaltic L1: ND N/A 3-tab roofing w/ sand Layer 2: Black asphaltic L2: ND N/A 10527-R-75 Block H Roof, vapor barrier Covered Walkway Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Black asphaltic L4: ND N/A vapor barrier ehsi ENS-International.Inc. 89 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATIERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Black asphaltic L1: ND N/A 3-tab roofing w/ sand Layer 2: Black asphaltic L2: ND N/A 10527-R-76 Block H Roof, W. vapor barrier Side Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Black asphaltic L4: ND N/A vapor barrier Layer 1: Silver Coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 4: Black asphaltic L4: ND N/A vapor barrier 10527-R-77 Block L Roof, E. Layer 5: Yellow foam L5: ND N/A Low Roof insulation Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Yellow foam L7: ND N/A insulation Layer 8: White paper L8: ND N/A vapor barrier Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 4: Black asphaltic L4: ND N/A vapor barrier 10527-R-78 Block L Roof, S. Layer 5: Yellow foam L5: ND N/A High Roof insulation Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Yellow foam L7: ND N/A insulation Layer 8: White paper L8: ND N/A vapor barrier ehs .' 90 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 4: Black asphaltic L4: ND N/A vapor barrier 10527-R-79 Block L Roof, N. Layer 5: Yellow foam L5: ND N/A High Roof insulation Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Yellow foam L7: ND N/A insulation Layer 8: White paper L8: ND N/A vapor barrier Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 4: Black asphaltic L4: ND N/A 10527-R-80 Block M Roof, N. vapor barrier High Roof Layer 5: Yellow foam L5: ND N/A insulation Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Yellow foam L7: ND N/A insulation Layer 1: Silver coat L1: ND N/A Layer 2: Black asphaltic L2: ND N/A built-up roofing Layer 3: Brown insulation L3: ND N/A Layer 4: Black asphaltic L4: ND N/A 10527-R-81 Block M Roof, E. vapor barrier Low Roof Layer 5: Yellow foam L5: ND N/A insulation Layer 6: Black asphaltic L6: ND N/A vapor barrier Layer 7: Yellow foam L7: ND N/A insulation 10527-R-82 Block M Roof, E. White/gray flex duct ND N/A Low Roof (2'X3') 10527-R-83 Block M Roof, E. White flex duct (8" round) ND N/A Low Roof Block M Roof, E. Black asphaltic 10527-R-84 Low Roof penetration sealant on 4% Chrysotile lead vent pipe ehsi ENS-International,Inc. 91 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Covered Walkway Layer 1: Black asphaltic L1: ND N/A 10527-R-85 Roof between 3-tab roofing w/ sand Block A and C Layer 2: Black asphaltic L2: ND N/A vapor barrier Layer 1: Black asphaltic L1: 4% Chrysotile tar Layer 2: Black asphaltic L2: ND N/A 10527-R-86 Block N (P1) built-up roofing Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Brown paper L4: ND N/A vapor barrier (on wood) Layer 1: Black asphaltic L1: 4% Chrysotile tar Layer 2: Black asphaltic L2: ND N/A 10527-R-87 Block N (P1), built-up roofing East Side Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Brown paper L4: ND N/A vapor barrier (on wood) Layer 1: Black asphaltic L1: 4% Chrysotile Block N (P1), roof' patch 0527-R-88 Layer 2: Trace silver coat L2: ND N/A East Side Layer 3: Black asphaltic L3: ND N/A built-up roofing on wood Block N (P1), East Black asphaltic 10527-R-89 Side penetration sealant on ND N/A conduit Layer 1: Silver coat L1: 2% Chrysotile Layer 2: Black asphaltic L2: ND N/A Block M, West built-up roofing 10527-R-90 Entryway Layer 3: Black asphaltic L3: ND N/A vapor barrier Layer 4: Black asphaltic L4: ND N/A tar on concrete Layer 1: Trace Silver Coat L1: ND N/A Block M, West Layer 2: Black asphaltic L2: 4% Chrysotile 10527-R-91 tar Entryway Layer 3: Black asphaltic built-up roofing w/ tar L3: ND N/A 10527-R-92 P2 Roof Black asphaltic 3-tab ND N/A roof nic 10527-R-93 P2 Roof Black asphaltic 3-tab ND N/A roofing ehsi�. 92 EHS-International,Inc. • t Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Trace beige L1: ND N/A Central Covered coating 10527-R-94 Walkway, N. Layer 2: Black asphaltic L2: 18% Chrysotile Side fibrous coating Layer 1: Trace beige L1: ND N/A 10527-R-95 Central Covered coating w/white paint L2: 21% Chrysotile Walkway, Center Layer 2: Black asphaltic fibrous coating Layer 1: Trace beige L1: ND N/A 10527-R-96 Central Covered coating L2: 17% Chrysotile Walkway, S. Side Layer 2: Black asphaltic fibrous coating Layer 1: Trace beige L1: ND N/A 10527-R-97 S. Entrance to coating L2: 20% Chrysotile Block A Layer 2: Black asphaltic fibrous coating Layer 1: Trace beige L1: ND N/A 10527-R-98 W. Entrance to coating L2: 21% Chrysotile Block C Layer 2: Black asphaltic fibrous coating PORTABLE 1 (P1) Layer 1: 12"x12" Light L1: ND N/A yellow VCT w/ white 10527-P1-01 Portable 1, streaks Northwest Corner Layer 2: Yellow and black L2:ND N/A mastic Layer 3: Wood subfloor L3: ND N/A Layer 1: 4"Tan cove base L1: ND N/A Layer 2: Cream colored 10527-P1-02 Portable 1, mastic L2: ND N/A Northeast Corner Layer 3: Remnant Brown L3: ND N/A mastic Layer 1: Beige wall L1: ND N/A covering w/paint 10527-P1- Portable 1, NW Layer 2: White wall L2: 52% Chrysotile 03 Corner cover backing Layer 3: JC w/ paper L3: ND N/A Layer 4: GWB w/ paper L4: ND N/A (corner) ehsi ENS-International.Inc. 93 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: Beige wall L1: ND N/A 10527-P1- Portable 1, West covering 04 Wall Layer 2: White wall L2: 51% Chrysotile cover backing Layer 3: GWB (mid wall) L3: ND N/A Layer 1: Beige w/ green L1: ND N/A wall covering 10527-P1- Portable 1, East Layer 2: White wall L2: 52% Chrysotile 05*7 Wall cover backing Layer 3: JC w/ paper L3: 0.5% Chrysotile Layer 4: GWB (mid wall) L4: ND N/A 10527-P1Portable 1, Ceiling, Layer 1: JC w/paint L1: 0.75% Chrysotile 06*7 East Layer 2: GWB (ceiling L2: ND N/A _ edge) 10527-P1-07 Portable 1, Ceiling, GWB w/ paper and paint ND N/A _East (mid ceiling) Layer 1: 1'x1' White ACT L1: ND N/A w/ pin hole pattern 10527-P1- Portable 1, Ceiling, Layer 2: Dark brown glue L2: ND N/A 08QA Southeast dot Layer 3: 1'x1 ACT debris L3: ND N/A Layer 4: Brown glue dot L4: ND N/A 10527-P1-09 Portable 1, North Gray window glazing putty ND N/A Wall Layer 1:Remnant chalk L1: ND N/A 10527-P1-10 Portable 1, West board backing Wall Layer 2: Cork board L2: ND N/A Layer 2: Brown mastic L3: ND N/A Portable 1, Layer 1: Beige paint 10527-P1-11 Exterior, North Layer 2: Black asphaltic ND N/A Wall vapor barrier Portable 1, Layer 1: Gray window L1: 3% Chrysotile 10527-P1- glazing putty Exterior, North 12 Wall Layer 2: Trace yellow L2: ND N/A mastic Portable 1, Layer 1: Black asphaltic L1: ND N/A 10527-P1-13 vapor barrier Exterior, East Wall Layer 2: GWB w/. paper L2: ND N/A PORTABLE 2 (P2) Layer 1: Blue multi- L1: ND N/A 10527-P2-01 Portable 2, colored carpet Conference Layer 2: Clear mastic L2: ND N/A Layer 3: Wood sub-floor L3: ND N/A et/Si94 EHS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: 4" Blue cove L1: ND N/A 10527-P2-02 Portable base 2,Conference Layer 2: Cream colored L2: ND N/A mastic 10527-P2-03 Portable 2, 2'X4' SACT w/ worm track ND N/A Classroom pattern Layer 1: Beige wall L1: ND N/A Portable 2, covering L2: ND N/A 10527-P2-04 Classroom Layer 2: Brown fiberboard Layer 3: JC w/ paint L3: ND N/A Layer 4: GWB w/ paper L4: ND N/A Layer 1: Beige wall L1: ND N/A Portable 2, covering w/paint L2: ND N/A 10527-P2-05Layer 2: Brown fiberboard Conference Layer 3: JC w/ paint L3: ND N/A Layer 4: GWB w/ paper L4: ND N/A L1: ND N/A Layer 1: Beige wall 10527-P2-06 Portable 2, Office covering w/paint L2: ND N/A Layer 2: Brown fiberboard Layer 3: GWB w/ paper L3: ND N/A L4: ND N/A COMMUNITY POOL Layer 1: Dark blue rubber L1: ND N/A flooring 10527-CP- Layer 2: White/beige L2: ND N/A 01 Office mastic Layer 3: Tan VAT L3: 2% Chrysotile Layer 4: Black mastic L4: 3% Chrysotile on concrete Layer 1: Dark blue Rubber L1: ND N/A flooring 10527-CP- Layer 2: White/beige L2: ND N/A 02 Lobby mastic Layer 3: Tan VAT L3: 2% Chrysotile Layer 4: Black mastic L4: 3% Chrysotile on concrete Layer 1: 4" Blue cove L1: ND N/A 10527-CP-03 Central Corridor base L2: ND N/A Layer 2: Beige/brown mastic eSI�►� ENS-International,Inc. 95 • . F Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Layer 1: 12"x 12" Sea L1: ND N/A Staff Men green VCT 10527-CP-04 Layer 2: Yellow mastic L2: ND N/A Restroom Layer 3: Trace black L3: ND N/A mastic w/ concrete dust Layer 1: 4" Black cove L1: ND N/A 10527-CP- Staff Men base 05QA Restroom Layer 2: Beige/brown L2: ND N/A mastic Layer 1: 1"x1" Blue L1: ND N/A ceramic floor tile 10527-CP-06 Men Locker Room L2: ND N/A Layer 2: Gray grout Layer 3: Dark gray mortar L3: ND N/A Layer 1: 4" Off-white L1: ND N/A 10527-CP-07 Men Locker Room ceramic wall tile Layer 2: White grout L2: ND N/A Layer 3: Dark gray mortar L3: ND N/A 10527-CP-08 Pool Area Layer 1: Red brick L1: ND N/A Layer 2: Gray grout L2: ND N/A Layer 1: JC w/ paint and L1: ND N/A 10527-CP-09 Men Locker Room paper Layer 2: GWB w/ paint L2: ND N/A and paper (ceiling edge) 10527-CP-10 Men Locker Room Layer 1: GWB w/ paint ND N/A (mid ceiling) 10527-CP- Layer 1: JC w/ paint L1: 0.5% Chrysotile 11`$ Lobby Layer 2: Brown GWB w/ L2: ND N/A paper (ceiling edge) 10527-CP-12 Lobby Brown GWB w/ paint (mid ND N/A ceiIiri ) 10527-CP- Layer 1: JC w/ paint L1: 0.5% Chrysotile 13*8 Lobby Layer 2: Brown GWB w/ L2: ND N/A paper (mid ceiling) 10527-CP- Women Locker JC/Brown GWB w/ paint 0.5% Chrysotile 14*8 Room (ceiling edge) 10527-CP-15 Women Locker Brown GWB w/ paint and ND N/A Room paper (mid ceiling) 10527-CP- Layer 1: JC w/ paint L1: 0.25% Chrysotile 16'$ Storage Room Layer 2: Brown GWB w/ L2: ND N/A paper (corner wall) Layer 1: JC w/ paint L1: ND N/A 10527-CP-17 Storage Room Layer 2: Brown GWB w/ L2: ND N/A paper (mid wall) ehsI..b ENS-International.Inc. 96 • • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS 10527-CP- Layer 1: JC w/ paint L1: 0.5% Chrysotile 18'$ Office Layer 2: Brown GWB w/ L2: ND N/A paper ( corner wall) 10527-CP-19 Office Brown GWB w/ paint and ND N/A paper (mid wall) 10527-CP-20 Staff Women Brown GWB w/ paint and ND N/A Restroom paper (mid wall) Staff Women Layer 1: Fiber reinforced L1: ND N/A 10527-CP-21 Restroom wall panel Layer 2: Clear mastic L2: ND N/A Gray caulking (between 10527-CP-22 Pool Area pool edge ceramic flooring ND N/A and concrete walkway) Dark brown/black interior window frame caulking 10527-CP-23 Pool Area (on 1'x8' metal framed ND N/A windows) 10527-CP-24 Pool Area Brown door frame ND N/A caulking 10527-CP-25 Pool Area White/beige caulking on ND N/A brick wall 10527-CP- White cloth flex duct 26 Boiler Room (4'x4') 60% Chrysotile 10527-CP-27 Boiler Room Black flex duct (2'x2') ND N/A 10527-CP-28 Boiler Room Silver paint on metal duct ND N/A Layer 1: Red seam L1: 2% Chrysotile 10527-CP- sealant w/ paint 29 Boiler Room Layer 2: Black asphaltic L2: 6% Chrysotile seam sealant w/mastic on AHU 10527-CP- Boiler Room Silver paint of boiler 2% Chrysotile 30 exterior Layer 1: Cloth L1: ND N/A 10527-CP- insulation wrap 31 Boiler Room Layer 2: MAG insulation L2: 6% Chrysotile on boiler exhaust duct 4% Amosite Layer 1: Cloth L1: ND N/A 10527-CP- insulation wrap 32 Boiler Room Layer 2: MAG insulation L2: 5% Chrysotile on boiler exhaust duct 4% Amosite Layer 1: Cloth L1: ND N/A 10527-CP- insulation wrap 33 Boiler Room Layer 2: MAG insulation L2: 6% Chrysotile on boiler exhaust duct 4% Amosite ehsI.) EHS-International,Inc. 97 • S Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS 10527-CP-34 Pool, West Wall White hard pool lining ND N/A material 10527-CP-35 Pool West, Floor White hard pool lining ND N/A material 10527-CP-36 Pool Center, Floor White hard pool lining ND N/A material 10527-CP-37 Pool, East Wall White hard pool lining ND N/A material 10527-CP- Pool Floor, East White hard pool lining ND N/A 38QA material Layer 1: 1"x 1"Tan L1: ND N/A ceramic floor tile L2: ND N/A 10527-CP-39 Women's Locker Layer 2: Gray/beige grout Room Layer 3: Trace white L3: ND N/A mastic Layer 4: Gray mortar L4: ND N/A Layer 1: 6"Tan ceramic L1: ND N/A 10527-CP-40 Pool Area cove base Layer 2: Gray/beige grout L2: ND N/A Layer 1: White cloth L1: ND N/A 10527-CP- Layer 2: Brown fiber L2: ND N/A 41 Office board Layer 3: Brown/black L3: 3% Chrysotile mastic Men's Locker 10527-CP- White cloth flex duct 58% Chrysotile 42 Room, Attic (3'x3') Space Men's Locker Layer 1: White cloth L1: ND N/A 10527-CP- Room Attic insulation wrap 43 Space Layer 2: TSI on small L2: 3% Amosite bore pipe elbow Men's Locker Layer 1: White cloth L1: ND N/A 10527-CP- Room Attic insulation wrap 44 Space Layer 2: TSI on small L2: 3% Amosite bore pipe elbow Men's Locker 10527-CP- TSI on small bore pipe ° 45 Room, Attic elbow 3% Amosite Space Layer 1: 12"x 12" Beige L1: ND N/A 10527-CP-46 Boiler Room VCT w/paint Closet/Office Layer 2: Yellow/clear L2: ND N/A mastic &mi.) 98 EHS-International Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 1 SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE MATERIAL ASBESTOS TYPE OF NUMBER LOCATION DESCRIPTION % ASBESTOS Exterior West Black/brown paper 10527-CP-47 Side (between metal siding and ND N/A brick wall) Exterior, West Black hard material 10527-CP-48 Side (between foundation wall ND N/A and brick wall) 10527-CP-49 Exterior, West Beige/gray door frame ND N/A Side caulking 10527-CP-50 Exterior, East Side Gray caulking (on metal ND N/A jacketed fiberglass runs) 10527-CP-51 Storage Room Cork board w/ tan/brown ND N/A mastic 10527 CP Lobby Reception Layer 1: Blue formica Li: ND N/A 52QA Area countertop Layer 2: Tan/red mastic L2: ND N/A EFIS= Exterior Finish Insulation System " When QA lab and primary lab sample results differed, EHSI reported the most restrictive (e.g., highest % asbestos) in Table 1. Analytical results for all analyses are provided in Appendix A. * Point counted samples 1 Preliminary analytical reports indicated that the plaster ceiling system in the 1952 Era Multi- Purpose Building (Block A) in the Federal Way High School contains approximately 2% Chrysotile asbestos. This ACM plaster ceiling system constitutes a surfacing material as defined by the AHERA regulation. EHSI re-submitted the plaster samples reported to have greater than 1% asbestos concentration for re-analysis using the more precise EPA "Point Count" method. The "Point Count" analytical method is recommended by the EPA for samples with less than 10% asbestos. Based on the results of that re-analysis, the skim coating on plaster ceiling was determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM "surfacing materials". Only the "Point Count" re-analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in Appendix A. 2 Preliminary analytical reports indicated that the joint compound (JC) "skim coating" on the GWB wall system in the Original 1937 Era Building (Block C) in the Federal Way High School contains approximately 2% Chrysotile asbestos. This ACM JC/GWB system constitutes a surfacing material as defined by the AHERA regulation. EHSI re-submitted the plaster samples reported to have greater than 1% asbestos concentration for re-analysis using the more precise EPA "Point Count" method. The "Point Count" analytical method is recommended by the EPA for samples with less than 10% asbestos. Based on the results of that re-analysis, the JC "skim coating" on GWB walls was determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM "surfacing materials". Only the "Point Count" re- e s 99 EHS-International.Inc. • S . Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in Appendix A. 3 Preliminary analytical reports indicated that the JC "skim coating" on the GWB and plaster wall systems in the 1954 Era Library and Classroom Building (Block D) in the Federal Way High School contains approximately 2% Chrysotile asbestos. This ACM JC/GWB/plaster ceiling system constitutes a surfacing material as defined by the AHERA regulation. EHSI re- submitted the plaster samples reported to have greater than 1% asbestos concentration for re-analysis using the more precise EPA "Point Count" method. The "Point Count" analytical method is recommended by the EPA for samples with less than 10% asbestos. Based on the results of that re-analysis, the JC "skim coating" on GWB and plaster wall/ceiling system was determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM "surfacing materials". Only the "Point Count" re-analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in Appendix A. 4 Preliminary analytical reports indicated that the gray mortar under the ceramic tile window sill in the 1962 Era Classroom Building (Block J)in the Federal Way High School contains <1% Chrysotile asbestos. EHSI re-submitted the mortar samples reported to have greater than <1% asbestos concentration for re-analysis using the more precise EPA "Point Count" method. The "Point Count" analytical method is recommended by the EPA for samples with less than 10% asbestos. Based on the results of that re-analysis, the mortar sample was determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM. Only the "Point Count" re-analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in Appendix A. 5 Preliminary analytical reports indicated that the JC "skim coating" on the GWB wall system in the 1957 Era Building (Block L) in the Federal Way High School contains approximately 2% Chrysotile asbestos. This ACM GWB system constitutes a surfacing material as defined by the AHERA regulation. EHSI re-submitted the JC/GWB samples reported to have greater than 1% asbestos concentration for re-analysis using the more precise EPA "Point Count" method. The "Point Count" analytical method is recommended by the EPA for samples with less than 10% asbestos. Based on the results of that re-analysis, the JC "skim coating" on GWB walls was determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM "surfacing materials". Only the "Point Count" re-analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in Appendix A. 6 Preliminary analytical reports indicated that the JC "skim coating" on the GWB and plaster wall and ceiling system in the 1957 Era Building (Block M) in the Federal Way High School contains approximately 2% Chrysotile asbestos. This ACM "skim coating" on the GWB/plaster wall/ceiling system constitutes a surfacing material as defined by the AHERA regulation. EHSI re-submitted the plaster samples reported to have greater than 1% asbestos concentration for re-analysis using the more precise EPA"Point Count" method. The "Point Count"analytical method is recommended by the EPA for samples with less than 10% asbestos. Based on the results of that re-analysis, the JC "skim coating" on GWB and plaster wall/ceiling system was determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM "surfacing materials". Only the "Point Count" re-analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in Appendix A. Preliminary analytical reports indicated that the GWB wall and ceiling system in Portable 1 Building on the Federal Way High School Campus contains approximately 2% and 3% Chrysotile asbestos. This ACM GWB system constitutes a surfacing material as defined by the ehs/ , ENS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 AHERA regulation. EHSI re-submitted the GWB samples reported to have greater than 1% asbestos concentration for re-analysis using the more precise EPA "Point Count" method. The "Point Count" analytical method is recommended by the EPA for samples with less than 10% asbestos. Based on the results of that re-analysis, the skim coating on GWB walls was determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM "surfacing materials". Only the "Point Count" re-analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in Appendix A. 8 Preliminary analytical reports indicated that the JC "skim coating" on the GWB wall and ceiling system in the Community Pool Building on the Federal Way High School Campus contains approximately 2% to 3% Chrysotile asbestos. This ACM JC "skim coating" on the GWB wall system constitutes a surfacing material as defined by the AHERA regulation. EHSI re-submitted the GWB samples reported to have greater than 1% asbestos concentration for re-analysis using the more precise EPA "Point Count" method. The "Point Count" analytical method is recommended by the EPA for samples with less than 10% asbestos. Based on the results of that re-analysis, the JC "skim coating" on GWB walls was determined to be a non- ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM "surfacing materials". Only the "Point Count" re-analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in Appendix A. Washington State Department of Labor and Industries (L&I) requires special worker exposure precautions and qualifications when dealing with ACM used on seams and nail holes (refer to L&I regulations and WISHA Regional Directives {WRD}), Similar requirements exist for walls and ceilings skim-coated with material that contains less than one percent (<1%) asbestos fibers. Any "dust creating activity", such as: sanding, sawing, grinding, or drilling of GWB walls or ceilings shall be accomplished by certified asbestos workers using glove-bag, mini-enclosure and/or negative pressure enclosure engineering controls and work practices. As directed by WRD 23.30, for all other demolition or disturbance of GWB walls/ceilings with ACM JC or of walls/ceilings skim coated with <1% asbestos, employees shall have received at least two hours of asbestos awareness training as specified L&I instruction 296-62-07722(5). Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos fibers during its survey, and un-sampled materials assumed to be ACM. The Table 2 Summary of Asbestos Containing Materials is for engineering cost estimating purposes and is not intended for bid quantifications. TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED Block A Multiple layers of ACM black asphaltic built up roofing with ACM tar on non- Interstitial Space above 6,550 SF ACM brown fibrous insulation on ACM Boy's Locker Room ' black asphaltic vapor barrier on wood ehsi EHS-Intemational,Inc. 10 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 ` July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED Non-ACM 12"x12" VCT w/ non-ACM yellow mastic on non-ACM gray Gym Corridor 9,250 SF leveling compound on ACM black mastic on concrete ACM brown stair tread on non-ACM 2nd Floor Stairwell 1 and green, brown, and yellow mastic on 2 500 SF wood ACM brown SVF stair landing on non- 2nd Floor Stairwell 1 and 250 SF ACM yellow mastic on wood 2 ACM 8" stair stringer w/ non-ACM 2nd Floor Stairwell 1 and 325 LF brown mastic 2 Carpet w/ non-ACM yellow carpet mastic on 9"x9" burnt orange VAT w/ Marketing A75 1,000 SF non-ACM black mastic on concrete Carpet w/ non-ACM yellow carpet mastic on non-ACM gray leveling Marketing A75 Storage 250 SF compound on 9"x9" burnt orange VAT A76 and A77 w/ non-ACM black mastic on concrete Blue carpet w/ non-ACM yellow carpet mastic on non-ACM gray leveling ASB A5 500 SF compound on ACM residual black mastic on concrete Hard wood floor w/ non-ACM brown paper vapor barrier w/ non-ACM black asphaltic backing on hardwood floor Main Gymnasium 12,000 SF sleepers on ACM multi-layered black asphaltic vapor barrier beneath tarred to concrete Lockers A10, Lockers A24, Exercise A33, Assumed ACM white board mastic Training A38, Lockers 10 EA A50/A60, and marketing A75 Assumed ACM tack board mastic Marketing A75 5 EA Assumed ACM cabinet mastic Weights A39 25 SF Boy's and Girl's Locker Assumed ACM mirror mastic Rooms, Weight Room 15 EA A39, and Restroom Assumed ACM electrical panel backing Mechanical Room 10 EA Assumed ACM fire doors Throughout 65 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block B ehsi ,o EHS-International,Inc. Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL • ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED Non-ACM 12"x12" blue VCT w/ non- ACM yellow mastic on ACM residual Cafeteria B1/B2 6,000 SF black mastic on concrete ACM Gray window glazing putty on Corridor B5 3 EA 4'x5' windows Non ACM 4"tan/gray CB w/ non ACM creme colored mastic on ACM residual Corridor B5 450 LF brown mastic on concrete ACM Gray window glazing putty on Cafeteria B2 9 EA 4'x3' clearstory windows Assumed ACM mirror mastic Kitchen Restroom, 2 EA Kitchen 5-9 Assumed ACM white board mastic Throughout 2 EA Assumed ACM fire doors Throughout 12 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block C ACM black sink undercoat Faculty Lounge 1 EA Non-ACM 12"x12" blue VCT w/ non- ACM yellow mastic on non-ACM gray Original Building 2, OOOSF leveling compound on ACM residual Corridor C 116 black mastic on concrete Non-ACM 12"x12" light gray VCT w/ non-ACM yellow/tan mastic on non Original Building ACM gray leveling compound on 9"x9" Corridor C 116 200 SF black VAT w/ ACM black mastic on concrete Non-ACM 12"x12" off-white VCT (w/ brown, yellow, and white streaks) w/ Original Building non-ACM yellow mastic on non-ACM passage C 115 250 SF gray leveling compound on ACM residual black mastic on concrete Carpet w/ non-ACM beige and yellow carpet mastic on 12"x12" off-white non-ACM VCT (w/ brown, yellow, and Original Building white streaks) w/ non-ACM yellow Copy C 111, Data 525 SF mastic on non-ACM gray leveling Processing, Conference compound on ACM residual black C 108 mastic on concrete ehsi �o EH�Intemational,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED Non-ACM light gray SVF (w/ broken rock pattern) w/ non-ACM brown paper backing w/ non-ACM mastic on non- Janitor C-110 100 SF ACM gray/brown leveling compound on ACM residual black mastic on concrete Blue carpet w/ non-ACM yellow/brown mastic on non-ACM gray leveling Original Building C-107 775 SF compound on ACM residual black mastic on concrete Carpet w/non-ACM yellow/tan mastic on non-ACM gray leveling compound Original Building Girls C- 325 SF on 9"x9" black VAT w/ ACM black 135 mastic on concrete Non-ACM orange SVF (with yellow and Original Building 2nd brown streaks) with non-ACM yellow Floor Janitor Closet C- 100 SF mastic w/ ACM gray paper backing on 217 ACM residual black mastic on concrete Non-ACM light gray SVF (w/ broken rock pattern) with non-ACM beige Original Building 2nd paper backing and non-ACM beige 500 SF mastic w/ 9"x9" black VAT w/ ACM Floor Storage C-218 black mastic on concrete Non-ACM 12"x12" off-white VCT (w/ brown, yellow, and white streaks) with non-ACM yellow mastic on non-ACM Original Building 2nd 1,400 SF gray leveling compound on 9"x9" black Floor Corridor C-216 VAT w/ ACM black mastic on wood Carpet with non-ACM yellow mastic on Original Building 2nd 9"x9" dark red VAT w/ ACM black Floor E. Classroom C- 645 SF mastic on wood 206 Carpet with non-ACM yellow/brown mastic on ACM residual black mastic on Original Building 2"d non-ACM fiberboard with non-ACM Floor E. Classroom C- 400 SF clear coat on hard wood floor on non- 206 ACM black vapor barrier ACM NicoliteTM in wood fire wall Original Building Attic 300 SF ACM Black asphaltic sealant at vent Original Building Attic 50 EA penetration ACM MAG TSI pipe run (<6" OD) in Original Building 2nd wall Floor Room 45 LF Replacement of Stairs ehsie) EHS-International,Inc. 10 s • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED Carpet with non-ACM yellow mastic on Building Addition 2nd 9"x9" gray VAT w/ ACM black mastic Floor E. Classroom C 3,075 SF on wood 211, C-212, C-213, C- 215, and Corridor C-214 Non-ACM 12"x12" off-white VCT (w/ brown, yellow and white streaks) w/ Building Addition 1St non-ACM yellow mastic on non-ACM Floor Nurse C-126 and 325 SF gray leveling compound on ACM Office C-128 residual black mastic on concrete Carpet w/ non-ACM yellow mastic on Building Addition 1St 9"x9" off-white and gray VAT w/ ACM Floor Vice Principal C- 675 SF black mastic on concrete 125 and Clerical C-122 Carpet w/ non-ACM yellow carpet mastic on non-ACM gray leveling Waiting C-129 145 SF compound on ACM residual black mastic on concrete 2nd Floor Original Building E. Classroom C- 201-208, Stairwell replacement classroom, Listening C-210 1st Floor Assumed ACM white board mastic Building Addition, V.P. 50 EA 123, 124, 125, Principal C-120, Conference C- 119, 2nd Floor Building Addition Computers C- 212, E. Classroom C- 211,213 and C-205 2nd floor Original Assumed ACM tack board mastic Building E. Classroom C- 5 EA 206 ehS/..� ENS-international,Inc. 10 • S Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED 1st Floor Building Addition 1st Floor Building Addition, V.P. 123, 124, 125, Principal C-120, Conference C- 119, Waiting C-129, ATI C132, BKPR C-131, Assumed ACM mastic associated with Work C-130, Wait C- 1,000 SF wood wall paneling 121, 2nd Floor Original Building E. Classroom C- 201-208, Stairwell replacement classroom, 2nd Floor Building Addition Computers C- 212, E. Classroom C- 211,213 and C-205 2nd Floor Original Building E. Classroom C- 201-C-208 Assumed ACM cabinet mastic 2nd Floor Building 120 SF Addition Computers C- 212, E. Classroom C- 211,213 and C-205 Assumed ACM locker mastic 2nd Floor Original 200 SF Building Corridor C-216 1st Floor Original Assumed ACM mirror mastic Building Girls C 135, 6 EA and 2nd Floor Original Building C-220 Assumed ACM electrical panels and 1st Floor Boiler Room 10 EA components and 2nd Floor C-127 Assumed ACM fire doors Throughout 20 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block D Library D-15, Blue carpet with non-ACM yellow/tan Conference D-16 Audio mastic on ACM residual black mastic on Video Classroom D 17, 2,500 SF concrete Alcove D-18, Work Room D-19 and Magazine D-20 1 White NicloliteTM paper in wood fire Library Attic 500 SF wall ehs1-4.0 10 EHS-International,Inc. • I Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED Non-ACM silver paint on ACM black Library Attic 5 SF asphaltic tar/sealant Carpet w/ non-ACM gray foam carpet backing w/ non-ACM clear mastic on non-ACM 12"x12" off-white VCT (w/ Corridor D-14 1,750 SF brown, yellow, and white streaks) w/ non-ACM yellow mastic on ACM residual black mastic on concrete Carpet with non-ACM brown and orange mastic on 9"x9" tan VAT (w/ Corridor D-14 1,750 SF white and brown streaks) w/ ACM black mastic on concrete Carpet w/ non-ACM gray foam carpet backing w/ non-ACM clear/yellow Corridor D-13 375 SF mastic on ACM residual black mastic on concrete ACM black sink undercoat Office D-11 1 EA A.V. Classroom D-17, Assumed ACM white board mastic Conference D-16, S.S. 40 EA Classrooms D-1-D-8 Assumed ACM tack board mastic Library D-15, 1 EA Library D-15, A.V. Assumed ACM mastic associated with Classroom D-17, 1,000 SF wood wall paneling Corridor D-14 and Classrooms D-1-D-8 Assumed ACM mastic associated with Library D-15 and Office 500 SF wall mounted book cases D-11 and Library D-15, A.V. Assumed ACM mastic associated with Classroom D-17, 500 SF casework Corridor D-14, MAG D- 20,and Storage Assumed ACM univent internals Library 12 EA Assumed ACM locker mastic Corridor D-14 105 SF Assumed ACM fire doors Throughout 20 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block E ettsi4 EHS-International,Inc. 10 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED Non-ACM 12"x12" light gray VCT with non-ACM off-white and yellow mastic Corridor E-8 1,675 SF on ACM residual black mastic on concrete Non-ACM 12"x12" blue VCT with non- ACM yellow mastic on ACM residual Corridor E-8 1,675 SF black mastic on concrete Carpet with non-ACM yellow mastic on Vestibule E-25 125 SF ACM residual black mastic on concrete Carpet with non-ACM yellow mastic on Social Studies 9"x9" light blue VAT w/ ACM black 105 SF Classroom E-21 mastic on concrete 9"x9" Light brown VAT with ACM black Theater E-10 and 250 SF mastic on concrete Control E-11 Carpet with non-ACM yellow and Drama Classroom E-1, orange mastic on 9"x9" tan VAT w/ Green Room E-7 and 1,075 SF ACM black mastic on concrete Dressing E-5 Drama Classroom E-1, Assumed ACM white board mastic Passage E 2, and 26 EA Classroom E-17 2001 Addition Classrooms 1-5 Drama Classroom E-1, Assumed ACM mastic associated with Green Room E-7, S.S. 250 SF wood wall paneling; Classroom E-21, and Classroom E-17 Assumed ACM mastic associated with Corridor E-8 275 SF wall panels Assumed ACM wiring associated with Theater 30 EA theatre stage lighting 350 LF Assumed ACM mirror mastic Women E-4 3 EA Assumed ACM fire doors Throughout 15 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block F Laundry F-2, Storage F- Non-ACM 12"x12" off-white VCT (with 3, Cooking F-4, Office F- brown, yellow, and white streaks) w/ 5, Dress F-6, Storage F- 3,425 SF non-ACM yellow mastic on ACM 7, Sewing F-8, Storage residual black mastic on concrete and Child Development F-11 9"x9"Tan VAT (with brown and yellow streaks) w/ ACM black mastic on Electrical F-1 50 SF concrete _ e si EHS-Intemationai.Inc. 10 • Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED 9"x9" Light brown VAT (w/ rainbow streaks) w/ ACM black mastic on Electrical F-1 50 SF concrete 9"x9" Olive green VAT w/ ACM black Biology Classroom 1 and 2,745 SF mastic on concrete 2 9"x9" Brown/red VAT (with beige streaks) w/ ACM black mastic on Storage F-17 and F-18 265 SF concrete Carpet w/ non-ACM clear mastic on 12"x12" beige VAT (with brown Electronics F-19 and 2,325 SF streaks) on ACM black mastic on Drafting F-16 concrete Carpet with non-ACM yellow mastic on"9x9" red VAT w/ ACM black mastic Special Education F-13 725 SF on concrete Carpet w/ non-ACM green/gray mastic w/ non-ACM yellow mastic on 9"x9" Special Education F-15 700 SF light brown VAT (w/ rainbow streaks) w/ ACM black mastic on concrete ACM black sink undercoat Sewing F 8, Electronics 3 EA F-19 and Drafting F-16 Cooking F-4, Sewing F- 8, Child development F- Assumed ACM mastic associated with 11, Special Ed F-13,15, 200 SF wood wall paneling Drafting F-16, Electronics F-19, and Biology Classroom's Assumed ACM wall panel mastic Corridor F-9, 10, and 15 1,000 SF Cooking F-4, Sewing F- 8, Child development F- Assumed ACM white board mastic 11, Special Ed F 13,15, 22 EA Drafting F-16, Electronics F-19, and Biology Classroom's Assumed ACM tack board mastic Special Ed F 13, 5 EA Corridor F-15 Assumed ACM mirror mastic Toilet F-12 5 EA ehsi• EHS-International,Inc. 10 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY LOCATION EXPECTED TO BE DESCRIPTION _ IMPACTED Cooking F-4, Sewing F- 8, Child development F- 11, Special Ed F-13,15, Assumed ACM mastic associated with Drafting F-16, 575 SF casework Electronics F-19, and Biology Classroom's, Storage F-17 and 18, Biology Prep Rooms Assumed ACM locker mastic Corridor F-9, 10, and 15 200 SF Assumed ACM electrical panels and Mechanical Room and 9 EA components Electrical F-1 Assumed ACM fire doors Throughout 20 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block G Non-ACM 12"x12" light gray VCT (with white and gray streaks), blue VAT, and gray VAT (w/ maroon streaks) all w/ Corridor G-13 850 SF non-ACM tan mastic on non-ACM white leveling compound on gray VAT w/ ACM black mastic on wood Blue/gray carpet with non-ACM tan Janitor G-9, Storage G- mastic on tan VAT w/ ACM black 10A, Storage G-11, and 400 SF mastic on wood Storage G-3 Conference G-2A, Classroom G-2, Blue/gray carpet with non-ACM tan Simulators G 1, mastic on gray VAT w/ ACM black Business Classroom G- 5, 095 SF 4, Computer G-5, mastic on wood Keyboard Classroom G- 6, and Micro Computer G-7 Corridor G-13, Conference G-2A, Classroom G-2, Assumed ACM mastic associated with Simulators G 1, wood wall paneling Business Classroom G- 275 SF 4, Computer G-5, Keyboard Classroom G- 6, and Micro Computer G-7 (3hIs. 1 1 EHS-International,Inc. Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED Conference G-2A, Classroom G-2, Simulators G-1, Assumed ACM mastic associated with Business Classroom G- 225 SF casework 4, Computer G-5, Keyboard Classroom G- 6, and Micro Computer G-7 Classroom G-2, Simulators G-1, Business Classroom G- Assumed ACM white board mastic 4, Computer G-5, 12 EA Keyboard Classroom G- 6, and Micro Computer G-7 Assumed ACM locker mastic Corridor G-13 50 SF Assumed ACM electrical panels and Business Office G-10 4 EA components Assumed ACM fire doors Throughout 12 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block H Non-ACM 12"x12" beige VCT (w/ Main Corridor, Room brown and white streaks) w/ ACM 704,705, and Office 2,750 SF black mastic on concrete Area Non-ACM white leveling compound on non-ACM gray leveling compound on Janitor's Closet 5 SF ACM residual black mastic on concrete Multi-colored carpet w/ non-ACM foam backing w/ non-ACM clear mastic on non-ACM 12"x12" beige VCT (w/ brown ASA Room 975 SF and white streaks) w/ ACM black mastic on concrete Assumed ACM mastic associated with ASA Room 25 SF wood wall paneling Assumed ACM white board mastic ASA Room, Room 704 6 EA and 705 Assumed ACM tack board mastic ASA Room, Room 704 2 EA and 705 Assumed ACM mastic associated with ASA Room, Room 704 50 SF casework and 705 Assumed ACM locker mastic Main Corridor 50 SF ehsi 4.0 EHS-International,Inc. 11 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED Assumed ACM electrical panels and Main Corridor 3 EA components Grooming, Boy's Assumed ACM mirror mastic Restroom and Girl's 6 EA Restroom Assumed ACM fume hood baffles and Room 704 and 705 2 EA internals Assumed ACM fire doors Throughout 12 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block J Carpet w/ non-ACM yellow mastic on Math Classroom 3-5 and 9"x9" brown/red VAT w/ non-ACM 3-8 1 1,705 SF mastic on concrete Non-ACM 12"x12" light gray VCT w/ non-ACM dark gray mastic on 9"x9" Corridor 3-2 and 3-11 2 2,000 SF light blue VAT (w/ white streaks) w/ black mastic on concrete Carpet w/ non-ACM yellow mastic on 9"x9" tan VAT (w/ brown and yellow Math Classroom 3-7 and 1,700 SF streaks) w/ non-ACM black mastic on Health 3-10 3 concrete 9"x9" Red VAT on ACM black mastic Math Classroom 3-9 and beneath non-ACM carpet with non-ACM J_6 4 1,700 SF carpet mastic on concrete Assumed ACM mastic associated with Corridor 3-2, Math wood wall paneling Classroom 3-5, 3-6, 3-7, 100 SF J-8, 3-9, Health 3-10 5 Assumed ACM wall panel mastic Corridor 3-2 and J-11 6 250 SF Assumed ACM tack board mastic Math Classroom J 9, 2 EA Health J-10 7 Math Classroom 3-5, 3- Assumed ACM white board mastic 6, 3-7, 3-8, 3-9, Health 24 EA J-10 8 Assumed ACM locker mastic Corridor 3-11 50 SF Assumed ACM mirror mastic Girls Restroom 1 EA Assumed ACM fire doors Throughout 12 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block K ehsi ♦. t> EHS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED Carpet w/ non-ACM yellow/tan mastic on 9"x9" red VAT w/ non-ACM black F.L. Classroom K 1, K 2, 2,085 SF mastic on concrete Math Office K-2 9"x9"Tan floor tile with brown and yellow streaks on non-ACM black F.L. Classroom K-9 845 SF mastic beneath non-ACM carpet on non-ACM yellow mastic on concrete 9"x9" Brown/red floor tile with beige streaks on ACM black mastic on F.L. Office K 6 and 405 SF concrete Conference K-7 Non-ACM 12"x12" dark gray floor tile on non-ACM yellow mastic on 9"x9" Corridor K-5 1,000 SF light blue VAT on ACM black mastic on concrete F.L. Classroom K-1, Computer K-3, Math Assumed ACM mastic associated with Classroom K 8, F.L. wood wall paneling Classroom K-9, F.L 200 SF Office K-6, Conference K-7, F.L. Classroom K-4, Math K-2 Assumed ACM wall panel mastic Corridor K-5 1,500 SF Assumed ACM tack board mastic Computer K-3 1 EA F.L. Classroom K-1, Computer K-3, Math Classroom K-8, F.L. Assumed ACM white board mastic Classroom K-9, F.L 17 EA Office K-6, Conference K-7, F.L. Classroom K-4, Math K-2 Assumed ACM locker mastic Corridor K-5 50 SF Assumed ACM fire doors Throughout 10 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block L 9"x9" Olive and light olive colored VAT Ceramics Lab L-5 1,635 SF w/ ACM black mastic on concrete 9"x9" Green VAT (w/ beige streaks) w/ Art Lab L-1 1,185 SF ACM black mastic on concrete Blue/gray carpet w/ non-ACM tan mastic on non-ACM white leveling compound on 9"x9" red VAT w/ ACM Office L-8 200 SF black mastic on concrete e si.. EHS-International.Inc. I I • 110 A Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY LOCATION EXPECTED TO BE DESCRIPTION IMPACTED Non-ACM red sheet vinyl flooring with Metal Shop L-13 and non-ACM black asphaltic backing on Office L-9 4,000 SF ACM black mastic on concrete ACM gray caulking around metal Corridor L-6 735 LF seismic wall brackets Assumed ACM mastic associated with Art Lab L 1, Ceramics wood wall paneling Lab L-5, Storage L-3 100 SF and L-4 6 Assumed ACM mastic associated with Art Lab L-1 75 SF casework Assumed ACM electrical panels and Metal Shop L-13 6 EA components Assumed ACM tack board mastic Office L-2 1 EA Assumed ACM white board mastic Art Lab L-land Shop 3 EA Classroom L-7 Assumed ACM locker mastic Corridor L-6 125 SF Assumed ACM fire doors Throughout 13 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Block M 9"x9" Olive colored VAT (w/ pink and beige streaks) w/ ACM black mastic on Choral M-26 1,700 SF concrete Non-ACM 12"x12" blue VCT w/ non Corridor M-1 and ACM yellow mastic on ACM residual 250 SF Corridor M-12 black mastic on concrete Non-ACM blue/gray carpet w/ non-ACM tan mastic on 9"x9" Olive colored VAT Passage M-28, Practice 185 SF (w/ pink and beige streaks) w/ ACM 3, M-29, and M-31 black mastic on concrete Ensemble M-13, Practice Non-ACM blue/gray carpet w/ non-ACM M 14, Practice M 15, tan mastic on 9"x9" red VAT w/ non Instrument M 19, Office 1,375 SF ACM black mastic on concrete M 20, Storage M 22, Library M-23, Storage _ M-24, Office M-25 Storage M-2, Mechanical Non-ACM 12"x12" light gray VCT (w/ M-5, Office/Lab M-9, maroon and white streaks) w/ ACM Storage M-34, Film M- 2,725 SF black mastic on concrete 35, Print M-36, Print M- 37, Photo Lab M-38 ehsi.. i t EI S-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED 9"x9"Yellow floor tile (w/ brown and black streaks) w/ ACM black mastic on Science Classroom M-11 1,455 SF concrete Physics Lab M-7, Assumed ACM mastic associated with Chemistry Lab M-6 Band wood wall paneling M-17, Office M-20, 175 SF Storage M-22, Photo Lab M-38 Physics Lab M-7 and associated Offices, Chemistry Lab M-6, Office Lab M-9, Sicence Classroom M-11, Assumed ACM mastic associated with Ensemble M 13, casework Instrument Storage M- 1, 500 SF 19, Office M-20, Storage M-22, Library M- 23,Office M-25, Storage M-34, Film M-35, Print M-36, and Photo Lab M- 38 Assumed ACM locker mastic Corridor M-12 225 SF Physics Lab M-7, Chemistry Lab M-6, Assumed ACM white board mastic Science Classroom M- 12 EA 11, Band M-17,Entry M- 18 Choral M-26, Photo Lab M-38 Physics Lab M-7, Assumed ACM fume hood baffles and Chemistry Office/Lab M- SEA internals 9, Science Classroom M- 11, Assumed ACM fire doors Throughout 15 EA Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 750 LF walls and ceilings) Tunnels ACM TSI debris, at floor penetration Utility Tunnel L/M NW 20 SF (4"OD pipe run) End ACM Army green/gray cable bracket Utility Tunnel L/M, at 250 EA mastic tunnel Hatch ACM Black asphaltic vapor barrier Utility Tunnel A/B 550 SF between concrete and wood forms ACM TSI on abandon 8" pipe run Utility Tunnel A/B 4 LF ehSim EHS-International,Inc. 1 1 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY LOCATION EXPECTED TO BE DESCRIPTION IMPACTED JC on crawl space access door (3'x3') Block G Crawl Space 1 EA Exterior ACM White caulking on steel columns Exterior Block L/M 1,200 LF ACM gray roll-up door frame caulking Exterior Block L 50 LF JB'x 14') ACM tan/gray door frame caulking Exterior Block F 15 EA _(.8'x14') ACM tan window frame caulking (3'x5') Exterior Block F 35 EA ACM gray window frame caulking Exterior Block M 6 EA J3'x5') ACM black asphaltic tar beneath non- ACM black asphaltic felt on concrete Block C Foundation 3,500 SF foundation wall Roof ACM Silver coat on ACM black asphaltic Block A Roof 17 EA tar on metal roof vent base ACM Silver coat on ACM asphaltic built up roofing on non ACM asphaltic vapor Block C Roof 1,000 SF barrier on non-ACM brown paper vapor barrier on wood roof deck ACM black asphaltic sealant on parapet Block D Roof 200 LF wall flashing ACM Black asphaltic lead vent pipe Block M Roof 28 EA penetration sealant ACM Silver coat on non-ACM built-up roofing on non-ACM black asphaltic Block M Roof 75 SF vapor barrier on non-ACM asphaltic tar on concrete ACM black asphaltic sealant on non- ACM black asphaltic built-up roofing Block M Roof 25 SF with tar beneath non-ACM silver coat ACM Black asphaltic tar on ACM built- up roofing on non-ACM black asphaltic P1 Roof 1,000 SF vapor barrier on non-ACM brown paper vapor barrier on wood roof deck ACM black asphaltic roof repair patch P1 Roof 15 SF Covered Walkways ACM Black asphaltic coating beneath Center Courtyard 5,600 SF non-ACM beige and white paint Portables (P1) ACM White wall cover backing Interior Walls I 1,200 SF e 51..E 11 EHIS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 2 SUMMARY OF ASBESTOS-CONTAINING MATERIALS FEDERAL WAY HIGH SCHOOL ASBESTOS MATERIAL QUANTITY DESCRIPTION LOCATION EXPECTED TO BE IMPACTED ACM gray window frame glazing putty Exterior Windows 14 EA (4'x8') and (3'x4') Assumed ACM electrical panels and Classroom 1 EA components Assumed ACM chalkboard mastic Classroom 1 EA Community Pool Non-ACM dark blue rubber flooring with non-ACM white/beige mastic on Office and Lobby 1 500 SF tan VAT w/ ACM black mastic on concrete ACM white cloth flex duct (4'x4') Boiler Room 2 4 EA ACM red seam sealant on ACM black Boiler Room 3 100 LF sealant (on AHU) ACM silver paint on boiler exterior Boiler Room 4 15 SF ACM TSI on boiler exhaust duct Boiler Room 5 200 LF (2'diameter) ACM brown/black glue dots associated Office 6 2 EA with fiber board wall panel (4'x8') ACM white cloth flex duct (3'x3') Men's and Women's 6 EA Locker Room Attic 7 AHU with assumed ACM internal Boiler Room 8 3 EA components Assumed ACM electrical panels Boiler Room and Boiler 15 EA Room Office 9 Assumed ACM fire doors Throughout 4 EA Assumed ACM flange gaskets Boiler Room 30 EA (associated with the boiler); Assumed ACM boiler internal Boiler Room 1 EA components Assumed ACM wall panels and Over Pool 1800 SF associated mastic (High bay pool area); Assumed ACM TSI on small bore pipe runs and fitting (concealed in plumbing Throughout 2,250 LF walls and ceilings) Assumed ACM TSI on large bore pipe runs and fittings under slab (associated Under concrete slab 2,250 LF with pool). ACM identified in this survey should not be disturbed unless handled by personnel who are properly trained and certified in asbestos work. Demolition and/or renovation activities by contractors may expose concealed suspect ACM. Contractors should be aware of the potential for concealed suspect ACM and have preplanned contingencies for the handling of suspect ACM discovered during renovation and/or demolition work. Any concealed suspect ehsi�a EHS-International,Inc. 1 1 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 ACM material that was not sampled or was assumed to be ACM and included in this report, must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and a certified laboratory. Contingency plans should include stopping work on identification of concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building Inspector. Concealed suspect material may include, but is not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cementitious board; asphalt or paper vapor barriers; vinyl floorings and mastics. 2.4.2 Lead-Containing Paint and Building Materials Seven hundred sixty-six (766) samples were analyzed for lead using the X-Ray fluorescence (XRF) analyzer. Results marked with "<LOD" are less than the limit of detection. XRF paint sample results ranged from 9.4 milligrams of lead per square centimeter (mg Pb/cm2) to less than the LOD and XRF sample results for lead-containing materials ranged from 37 mg Pb/cm2 to less than the LOD. The results are provided in a table 3 of this report. The results indicate that ninety-eight (98) of the materials were found to contain >_1.0 mg/cm2 lead using the XRF instrument and two hundred and two (202) of the surfaces were found to contain detectable levels of lead using the XRF. Bolded results indicate materials coated with "lead-based paint" (e.g., >1.0 mg/cm2) as defined by USEPA regulation 40CFR745 and Washington State Department of Commerce (Commerce) regulation WAC 365-230. In addition to the XRF samples, EHSI collected forty (40) bulk QA samples for laboratory analysis. Results marked with the "<" symbol are less than the detectable level. Bulk sample results ranged from 4.6000 to <0.0035 percent lead by weight. Building materials and paint containing detectable levels of lead are considered regulated by DOSH. Two (2) of the Quality Assurance (QA) bulk samples were found to contain levels of lead above 0.5 percent by weight and thirteen (13) of the QA bulk samples were found to contain detectable levels of lead. Table 3 summarizes XRF lead samples, including sample number, material description, substrate, color, location and analytical results. TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. (mg/cm2) 1 SELF- N/A N/A N/A N/A 2.67 CALIBRATION 2 CALIBRATION N/A RED N/A N/A 1 3 CALIBRATION N/A RED N/A N/A 1 4 CALIBRATION N/A RED N/A N/A 1 5 WALL CONCRETE BEIGE SMALL GYM BLOCK Al < LOD 805 6 WALL GWB BEIGE SMALL GYM BLOCK Al < LOD 805 7 VENT COVER METAL BEIGE SMALL GYM BLOCK Al < LOD 805 ehsi 11 ENS-International,Inc. 0 0 Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building (mg/cm z) 8 DOOR FRAME METAL LIGHT SMALL GYM BLOCK Al < LOD BROWN 805 9 DOOR METAL LIGHT SMALL GYM BLOCK Al < LOD BROWN 805 10 DOUBLE METAL BEIGE SMALL GYM BLOCK Al < LOD DOOR FRAME 805 11 DOUBLE METAL BEIGE SMALL GYM BLOCK Al < LOD DOOR 805 12 MIRROR WOOD WHITE SMALL GYM BLOCK Al 0.4 CABINET 805 13 WALL TRIM WOOD WHITE SMALL GYM BLOCK Al < LOD 805 14 WALL CMU WHITE CORRIDOR BLOCK Al < LOD A35 15 FIRE METAL WHITE CORRIDOR BLOCK Al < LOD EXTINGUISHE A35 R CABINET 16 DOOR FRAME METAL BLUE ROOM 804 BLOCK A2 < LOD 17 WALL CONCRETE BLUE WEIGHT BLOCK A2 < LOD ROOM 806 18 SOFFIT GWB WHITE WEIGHT BLOCK A2 < LOD ROOM 806 19 WALL CMU BEIGE MEN LOCKER BLOCK A2 < LOD ROOM 814 20 WINDOW METAL LIGHT MEN LOCKER BLOCK A2 < LOD FRAME BROWN ROOM 814 21 WALL CERAMIC WHITE MEN LOCKER BLOCK A2 < LOD ROOM 814 22 FLOOR CERAMIC TAN MEN LOCKER BLOCK A2 < LOD ROOM 814 23 COVE BASE CERAMIC ORANGE MEN LOCKER BLOCK A2 < LOD ROOM 814 24 CEILING GWB BEIGE MEN LOCKER BLOCK A2 < LOD ROOM 814 25 CEILING PLASTER BEIGE MEN LOCKER BLOCK A2 < LOD ROOM 814 26 ATTIC METAL BEIGE MEN LOCKER BLOCK A2 < LOD ACCESSROOM 814 DOOR 27 ATTIC METAL BEIGE MEN LOCKER BLOCK A2 < LOD ACCESS ROOM 814 DOOR 28 SPEAKER BOX METAL BLACK MEN LOCKER BLOCK A2 < LOD ROOM 814 29 DOOR FRAME METAL BEIGE MEN LOCKER BLOCK A2 < LOD ROOM 814 30 DOOR METAL GRAY MEN LOCKER BLOCK A2 < LOD ROOM 814 ehsi 6.4 ,1 ENS-International,Inc, • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 ` July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. Component Substrate Color Room Building Z # (mg/cm ) 31 LOCKERS METAL BLUE MEN LOCKER BLOCK A2 < LOD ROOM 814 32 ELECTRICAL METAL GRAY MEN LOCKER BLOCK A2 < LOD BOX ROOM 814 33 CONDUIT METAL BEIGE MEN LOCKER BLOCK A2 1.3 ROOM 814 34 EXHAUST FAN METAL BEIGE MEN LOCKER BLOCK A2 < LOD ROOM 814 35 CEILING WOOD BEIGE MEN LOCKER BLOCK A2 < LOD ROOM 814 36 CEILING WOOD BEIGE MEN LOCKER BLOCK A2 0.08 ROOM 814 37 STALL WOOD BLUE MEN LOCKER BLOCK A2 < LOD ROOM 814 38 CEILING CONCRETE BEIGE MEN LOCKER BLOCK A2 < LOD ROOM 814 39 SINK METAL BEIGE MEN LOCKER BLOCK A2 0.18 ROOM 814 40 SPRINKLER METAL BEIGE MEN LOCKER BLOCK A2 0.17 PIPE ROOM 814 41 FLOOR CERAMIC BEIGE MEN LOCKER BLOCK A2 < LOD ROOM 814 42 WALL CERAMIC WHITE MEN LOCKER BLOCK A2 22.4 ROOM 814 43 CEILING PLASTER WHITE MEN LOCKER BLOCK A2 < LOD RM 814 44 CEILING PLASTER WHITE MEN LOCKER BLOCK A2 < LOD RM 814 45 CEILING PLASTER WHITE MEN LOCKER BLOCK A2 < LOD ON RM 814 SILVER 46 WALL GWB LIGHT MAIN GYM BLOCK Al < LOD BROWN 47 SUPPORT METAL BEIGE MAIN GYM BLOCK Al 0.12 BRACE 48 WALL CMU WHITE MAIN GYM BLOCK Al < LOD 49 WALL CONCRETE OFF MAIN GYM BLOCK Al < LOD WHITE 50 COLUMN CONCRETE OFF MAIN GYM BLOCK Al < LOD WHITE 51 ELECTRICAL METAL GRAY MAIN GYM BLOCK Al < LOD PANEL 52 ELECTRICAL METAL GRAY MAIN GYM BLOCK Al < LOD PANEL 53 FLOOR WOOD BLUE MAIN GYM BLOCK Al < LOD MARKING 54 FLOOR WOOD RED MAIN GYM BLOCK Al < LOD MARKING elhiSi 416. EHS-International,Inc. 12 • • . Limited Hazardous Materials Survey Report Federal Way High School ' EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. Component Substrate Color Room Building #' (mg/cm2) 55 FLOOR WOOD WHITE MAIN GYM BLOCK Al < LOD MARKING 56 DUCTING METAL BEIGE MAIN GYM BLOCK Al < LOD STORAGE RM 57 HATCH METAL BROWN MAIN GYM BLOCK Al < LOD STORAGE RM 58 DOOR FRAME METAL BEIGE UPPER GYM BLOCK A2 < LOD 59 STAIR METAL BLUE UPPER GYM BLOCK A2 < LOD RAILING 60 STAIR TREAD CONCRETE BLUE UPPER GYM BLOCK A2 < LOD 61 WALL GWB BEIGE UPPER GYM BLOCK A2 < LOD 62 GUARD METAL BLUE UPPER GYM BLOCK A2 < LOD RAILING 63 DRAIN PIPE METAL WHITE UPPER GYM BLOCK A2 1 ROOM 808 64 DRAIN PIPE METAL WHITE UPPER GYM BLOCK A2 0.8 ROOM 808 65 DRAIN PIPE METAL WHITE UPPER GYM BLOCK A2 < LOD ROOM 808 66 HATCH METAL WHITE UPPER GYM BLOCK A2 < LOD ROOM 808 67 CALIBRATION N/A RED CALIBRATION N/A 0.9 68 CALIBRATION N/A RED CALIBRATION N/A 1 69 CALIBRATION N/A RED CALIBRATION N/A 1 70 SELF- N/A N/A SELF- N/A 2.41 CALIBRATION CALIBRATION 71 CALIBRATION N/A RED CALIBRATION N/A 1 72 CALIBRATION N/A RED CALIBRATION N/A 1 73 CALIBRATION N/A RED CALIBRATION N/A 1 74 WALL GWB YELLOW KITCHEN BLOCK B < LOD 75 WALL GWB BLUE KITCHEN BLOCK B < LOD 76 WALL GWB BEIGE KITCHEN BLOCK B < LOD 77 WALL GWB BEIGE KITCHEN BLOCK B < LOD 78 FLOOR CERAMIC RED KITCHEN BLOCK B < LOD 79 DOOR FRAME METAL BLUE KITCHEN BLOCK B < LOD 80 DOOR FRAME METAL BLUE KITCHEN BLOCK B < LOD 81 DOOR FRAME METAL YELLOW KITCHEN BLOCK B < LOD 82 COLUMN WOOD YELLOW KITCHEN BLOCK B < LOD 83 COLUMN WOOD YELLOW KITCHEN BLOCK B < LOD 84 COLUMN WOOD YELLOW KITCHEN BLOCK B < LOD ehs/.. EHS-International,Inc. 12 • • . Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. _ r (mg/cm ) 85 COLUMN WOOD BLUE CAFETERIA BLOCK B 0.7 86 BEAM WOOD BLUE CAFETERIA BLOCK B 1.4 87 DOOR FRAME METAL BLUE CAFETERIA BLOCK B < LOD 88 DOOR METAL YELLOW CAFETERIA BLOCK B < LOD 89 COLUMN WOOD BLUE CAFETERIA BLOCK B 0.9 90 COLUMN METAL BLUE CAFETERIA BLOCK B < LOD 91 WALL PLASTER BLUE CAFETERIA BLOCK B < LOD 92 WALL PLASTER WHITE CAFETERIA BLOCK B < LOD 93 ROLLUP METAL WHITE CAFETERIA BLOCK B < LOD DOOR FRAME 94 MESH METAL BLUE CAFETERIA BLOCK B < LOD SCREEN DOOR 95 WALL CONCRETE WHITE CAFETERIA BLOCK B 0.08 96 CEILING GWB WHITE CAFETERIA BLOCK B < LOD 97 WALL GWB WHITE CAFETERIA BLOCK B < LOD 98 WALL GWB WHITE CAFETERIA BLOCK B < LOD 99 TRUSS METAL WHITE CAFETERIA BLOCK B < LOD 100 CEILING METAL WHITE CAFETERIA BLOCK B < LOD 101 RECEPTION WOOD WHITE CAFETERIA BLOCK B < LOD COUNTER 102 WALL CERAMIC YELLOW KITCHEN BLOCK B < LOD 103 WINDOW METAL BEIGE KITCHEN BLOCK B 0.04 FRAME 104 DOOR FRAME METAL BEIGE KITCHEN BLOCK B 0.05 105 DOOR METAL BEIGE KITCHEN BLOCK B < LOD 106 WINDOW SILL WOOD WHITE KITCHEN BLOCK B < LOD 107 WALL CMU WHITE KITCHEN BLOCK B 0.08 108 RAILING METAL BLUE CAFETERIA BLOCK B < LOD 109 SPRINKLER METAL OFF CAFETERIA BLOCK B < LOD PIPE WHITE FILE STORAGE 110 SPRINKLER METAL OFF CAFETERIA BLOCK B < LOD PIPE WHITE FILE STORAGE 111 DOOR FRAME METAL BLUE CAFETERIA BLOCK B < LOD FILE STORAGE 112 DOOR METAL BLUE CAFETERIA BLOCK B < LOD FILE STORAGE 113 CEILING GWB BEIGE CAFETERIA BLOCK B < LOD FILE STORAGE 114 WALL GWB BEIGE CAFETERIA BLOCK B < LOD * FILE STORAGE sle 12 EHS-International,Inc. . . . • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. # (mg/cm2) 115 DUCT METAL WHITE CAFETERIA BLOCK B < LOD FILE STORAGE 116 CALIBRATION N/A RED CALIBRATION N/A 0.9 117 CALIBRATION N/A RED CALIBRATION N/A 0.9 118 CALIBRATION N/A RED CALIBRATION N/A 1 119 SELF- N/A N/A SELF- N/A 2.65 CALIBRATION CALIBRATION 120 CALIBRATION N/A RED CALIBRATION N/A 1 121 CALIBRATION N/A RED CALIBRATION N/A 1 122 CALIBRATION N/A RED CALIBRATION N/A 0.9 123 WALL CERAMIC YELLOW WOMEN BLOCK Al < LOD LOCKER ROOM 124 FLOOR CERAMIC TAN WOMEN BLOCK Al 0.05 LOCKER ROOM 125 WALL GWB BEIGE WOMEN BLOCK Al < LOD LOCKER ROOM 126 CEILING GWB BEIGE WOMEN BLOCK Al < LOD LOCKER ROOM 127 DOOR FRAME METAL LIGHT WOMEN BLOCK Al < LOD BROWN LOCKER ROOM 128 STAIRCASE METAL LIGHT BOILER ROOM BLOCK A2 0.03 RAILING BROWN 129 DOOR FRAME METAL BEIGE BOILER ROOM BLOCK A2 0.04 130 DOOR METAL BEIGE BOILER ROOM BLOCK A2 < LOD 131 WALL GWB BEIGE BOILER ROOM BLOCK A2 < LOD 132 PANELBOARD METAL GRAY BOILER ROOM BLOCK A2 < LOD 133 ELECTRICAL METAL GRAY BOILER ROOM BLOCK A2 < LOD PANEL 134 ELECTRICAL METAL DARK BOILER ROOM BLOCK A2 < LOD PANEL GRAY 135 TANK METAL BLACK BOILER ROOM BLOCK A2 < LOD 136 TANK METAL GRAY BOILER ROOM BLOCK A2 < LOD 137 CIRCULATION METAL RED BOILER ROOM BLOCK A2 0.1 PUMP 138 TANK METAL RED BOILER ROOM BLOCK A2 < LOD 139 TANK METAL RED BOILER ROOM BLOCK A2 < LOD 140 PIPE METAL RED BOILER ROOM BLOCK A2 < LOD 141 PIPE METAL RED BOILER ROOM BLOCK A2 < LOD 142 BOILER METAL BLUE BOILER ROOM BLOCK A2 < LOD 143 HOT WATER METAL TAN BOILER ROOM BLOCK A2 0.04 HEATER 144 BOILER PLATE METAL BLACK BOILER ROOM BLOCK A2 < LOD e si4 ,2 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building g� m cm2) 145 CALIBRATION N/A RED CALIBRATION N/A 0.9 146 CALIBRATION N/A RED CALIBRATION N/A 1.4 147 CALIBRATION N/A RED CALIBRATION N/A 1 148 SELF- N/A N/A SELF- N/A 2.38 _ CALIBRATION CALIBRATION 149 CALIBRATION N/A RED CALIBRATION N/A 0.9 150 CALIBRATION N/A RED CALIBRATION N/A 1 151 CALIBRATION N/A RED CALIBRATION N/A 1 152 WALL CONCRETE WHITE NORTH BLOCK C 0.06 CORRIDOR 153 DOOR FRAME METAL LIGHT NORTH BLOCK C < LOD BROWN CORRIDOR 154 DOOR METAL LIGHT NORTH BLOCK C < LOD BROWN CORRIDOR 155 WALL CONCRETE YELLOW NORTH BLOCK C 0.04 CORRIDOR 156 WALL GWB OFF NORTH BLOCK C < LOD WHITE CORRIDOR 157 ELECTRICAL METAL TAN NORTH BLOCK C < LOD PANEL CORRIDOR 158 WINDOW METAL WHITE NORTH BLOCK C 0.4 FRAME CORRIDOR 159 WINDOW SILL CONCRETE WHITE NORTH BLOCK C 0.09 CORRIDOR 160 ELECTRICAL METAL GRAY CUSTODIAL BLOCK C < LOD PANEL OFFICE 161 TRANSFORME METAL GRAY CUSTODIAL BLOCK C < LOD R OFFICE 162 CEILING TILE FIBER WHITE CUSTODIAL BLOCK C < LOD BOARD OFFICE 163 SPRINKER METAL RED SPRINKLER BLOCK C < LOD PIPE CLOSET 164 SPRINKER METAL RED SPRINKLER BLOCK C 0.3 PIPE FITTING CLOSET 165 SPRINKER METAL BLACK SPRINKLER BLOCK C < LOD PIPE FITTING CLOSET 166 SPRINKER METAL BLUE SPRINKLER BLOCK C < LOD PIPE FITTING CLOSET 167 COMPRESSOR METAL BLUE SPRINKLER BLOCK C < LOD CLOSET 168 CEILING PLASTER BEIGE SPRINKLER BLOCK C < LOD CLOSET 169 WALL PLASTER BROWN CENTRAL BLOCK C < LOD CORRIDOR 170 WALL PLASTER OFF CENTRAL BLOCK C < LOD WHITE CORRIDOR e si EHIS-International,Inc. 12 Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. Component Substrate Color Room Building (mg/cm2) 171 RAM RAILING METAL BROWN CENTRAL BLOCK C < LOD CORRIDOR 172 STAIRCASE METAL BLUE CENTRAL BLOCK C < LOD RAILING CORRIDOR 173 COLUMN PLASTER BROWN CENTRAL BLOCK C < LOD CORRIDOR 174 ROLLUP METAL TAN CENTRAL BLOCK C < LOD DOOR CORRIDOR 175 ROLLUP METAL TAN CENTRAL BLOCK C < LOD DOOR CORRIDOR 176 DOOR FRAME METAL BLUE CENTRAL BLOCK C < LOD CORRIDOR 177 ELEVATOR METAL BLUE CENTRAL BLOCK C < LOD DOOR FRAME CORRIDOR 178 ELEVATOR METAL TAN CENTRAL BLOCK C < LOD DOOR CORRIDOR 179 WINDOW METAL BLUE CENTRAL BLOCK C < LOD CORRIDOR 180 WALL GWB BROWN CENTRAL BLOCK C < LOD CORRIDOR 181 WALL GWB LIGHT CENTRAL BLOCK C < LOD BLUE CORRIDOR 182 WALL GWB LIGHT GIRLS BLOCK C < LOD GREEN RESTROOM 183 STALL METAL LIGHT GIRLS BLOCK C 3.1 GREEN RESTROOM 184 WALL CERAMIC OFF MEN BLOCK C 21.4 WHITE RESTROOM 185 FLOOR CERAMIC BEIGE MEN BLOCK C < LOD RESTROOM 186 STALL WOOD BLUE MEN BLOCK C < LOD RESTROOM 187 WALL CMU BEIGE FIRE ALARM BLOCK C 0.4 CABINET 188 TRANSFORME METAL GRAY FIRE ALARM BLOCK C < LOD R CABINET 189 SWITCH METAL GRAY FIRE ALARM BLOCK C 0.03 BOARD CABINET 190 FLOOR CONCRETE GRAY FIRE ALARM BLOCK C 1.4 CABINET 191 DOOR FRAME METAL BEIGE FIRE ALARM BLOCK C < LOD CABINET 192 DOOR METAL BEIGE FIRE ALARM BLOCK C < LOD CABINET 193 DOOR METAL BEIGE FIRE ALARM BLOCK C < LOD CABINET 194 LOCKERS METAL BLUE SOUTH BLOCK C < LOD CORRIDOR etsio EHS-International,Inc. 12 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 ' July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building (mg/cm2) 195 WALL GWB BEIGE FACULTY 102 BLOCK C < LOD 196 CABINET WOOD BEIGE FACULTY 102 BLOCK C < LOD 197 WINDOW WOOD BEIGE FACULTY 102 BLOCK C 0.5 FRAME 198 WINDOW SILL WOOD BEIGE FACULTY 102 BLOCK C < LOD 199 WALL GWB LIGHT 201 BLOCK C < LOD BLUE 200 WINDOW SILL WOOD LIGHT 201 BLOCK C 0.28 BLUE 201 DOOR FRAME METAL BEIGE 201 BLOCK C < LOD 202 WINDOW SILL WOOD BEIGE 207 BLOCK C 0.16 203 WALL GWB BEIGE 207 BLOCK C < LOD 204 ELECTRICAL METAL GRAY CUSTODIAL BLOCK C < LOD PANEL CLOSET 205 WALL GWB YELLOW BOYS BLOCK C < LOD 206 FLOOR CONCRETE BROWN BOYS BLOCK C 0.8 207 STALL METAL YELLOW BOYS BLOCK C 4.2 208 WALL HATCH WOOD YELLOW BOYS BLOCK C < LOD DOOR 209 BOILER METAL BLUE BOILER ROOM BLOCK C < LOD 210 HOT WATER METAL TAN BOILER ROOM BLOCK C 0.07 HEATER 211 WALL BRICK RED BOILER ROOM BLOCK C < LOD 212 DRAIN PIPE METAL BEIGE BOILER ROOM BLOCK C < LOD 213 WALL CONCRETE BEIGE BOILER ROOM BLOCK C < LOD 214 WALL CONCRETE BEIGE BOILER ROOM BLOCK C < LOD 215 WALL CONCRETE BEIGE BOILER ROOM BLOCK C < LOD 216 COLUMN CONCRETE BEIGE BOILER ROOM BLOCK C < LOD 217 TANK METAL SILVER BOILER ROOM BLOCK C < LOD 218 WINDOW METAL OFF BOILER ROOM BLOCK C 0.26 FRAME WHITE 219 CONDUIT METAL BEIGE BOILER ROOM BLOCK C < LOD 220 CIRCULATION METAL RED BOILER ROOM BLOCK C < LOD PUMP 221 ELECTRICAL METAL DARK BOILER ROOM BLOCK C < LOD PANEL GRAY 222 FLOOR CONCRETE GRAY BOILER ROOM BLOCK C < LOD 223 DOOR FRAME METAL BROWN BOILER ROOM BLOCK C < LOD 224 DOOR METAL BROWN BOILER ROOM BLOCK C 0.07 225 BURNER METAL BLUE BOILER ROOM BLOCK C < LOD ehsi. 12 EHS-International,Inc. s . Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. # (mg/cm2) PANEL BOARD 226 ELECTRICAL METAL GRAY BOILER ROOM BLOCK C < LOD PANEL 227 CALIBRATION N/A RED CALIBRATION N/A 1 228 CALIBRATION N/A RED CALIBRATION N/A 1 229 CALIBRATION N/A RED CALIBRATION N/A 1 230 SELF- N/A N/A SELF- N/A 2.57 CALIBRATION CALIBRATION 231 CALIBRATION N/A RED CALIBRATION N/A 1 232 CALIBRATION N/A RED CALIBRATION N/A 0.9 233 CALIBRATION N/A RED CALIBRATION N/A 0.9 234 WALL GWB BLUE LIBRARY 108 BLOCK D < LOD 235 DOOR FRAME METAL BEIGE LIBRARY 108 BLOCK D < LOD 236 WALL GWB YELLOW LIBRARY 108 BLOCK D < LOD 237 WALL GWB YELLOW LIBRARY 108 BLOCK D < LOD 238 WALL CERAMIC BEIGE LIBRARY 108 BLOCK D < LOD 239 WALL GWB LIGHT LIBRARY 108 BLOCK D 0.03 GREEN 240 DOOR FRAME METAL BEIGE LIBRARY 108 BLOCK D < LOD 241 DOOR METAL BEIGE LIBRARY 108 BLOCK D 0.04 242 WINDOW METAL BEIGE LIBRARY 108 BLOCK D < LOD FRAME INT OFFICE 243 WINDOW METAL BEIGE LIBRARY 108 BLOCK D < LOD FRAME INT OFFICE 244 WALL METAL BURGUN LIBRARY 108 BLOCK D < LOD DY 245 DOOR FRAME METAL DARK LIBRARY 108 BLOCK D < LOD BLUE 246 WINDOW WOOD OFF LIBRARY 108 BLOCK D 0.08 FRAME WHITE 247 WINDOW WOOD OFF LIBRARY 108 BLOCK D < LOD FRAME WHITE 248 WINDOW WOOD OFF LIBRARY 108 BLOCK D 0.14 FRAME WHITE 249 WINDOW SILL WOOD OFF LIBRARY 108 BLOCK D < LOD WHITE 250 RADIATOR METAL TAN LIBRARY 108 BLOCK D < LOD 251 CEILING GWB WHITE LIBRARY 108 BLOCK D < LOD 252 CEILING GWB WHITE LIBRARY 108 BLOCK D < LOD 253 PARTITION WOOD BEIGE LIBRARY 108 BLOCK D < LOD ehs/•4 EHS-International,Inc. 12 w 0 Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. # (mg/cm ) 254 PARTITION WOOD BEIGE LIBRARY 108 BLOCK D < LOD 255 PARTITION WOOD BEIGE LIBRARY 108 BLOCK D < LOD 256 PARTITION WOOD BEIGE LIBRARY 108 BLOCK D < LOD 257 WALL CORKBOAR BLACK LIBRARY 108 BLOCK D 9.9 D 258 WALL CORKBOAR BLACK LIBRARY 108 BLOCK D 9.4 D 259 WALL GWB OFF CENTRAL BLOCK D < LOD WHITE CORRIDOR 260 WALL GWB OFF CENTRAL BLOCK D < LOD WHITE CORRIDOR 261 WALL BRICK OFF CENTRAL BLOCK D < LOD WHITE CORRIDOR 262 LOCKER METAL BLUE CENTRAL BLOCK D < LOD CORRIDOR 263 WINDOW CONCRETE OFF CENTRAL BLOCK D < LOD WHITE CORRIDOR 264 RAILING METAL DARK CENTRAL BLOCK D < LOD BLUE CORRIDOR 265 WALL BRICK DARK CENTRAL BLOCK D < LOD BLUE CORRIDOR 266 SWITCHBOAR METAL GRAY MECH ROOM BLOCK D < LOD D 267 ELECTRICAL METAL GRAY MECH ROOM BLOCK D < LOD PANEL FRONT 268 ELECTRICAL METAL YELLOW MECH ROOM BLOCK D < LOD PANEL SIDE 269 WALL GWB BLUE 109 BLOCK D < LOD 270 DOOR TRIM WOOD BROWN CENTRAL BLOCK D < LOD . CORRIDOR 271 CALIBRATION N/A RED CALIBRATION N/A 0.9 272 CALIBRATION N/A RED CALIBRATION N/A 0.9 273 CALIBRATION N/A RED CALIBRATION N/A 0.9 274 SELF- N/A N/A SELF- N/A 2.62 CALIBRATION CALIBRATION 275 CALIBRATION N/A RED CALIBRATION N/A 0.9 276 CALIBRATION N/A RED CALIBRATION N/A 1 277 CALIBRATION N/A RED CALIBRATION N/A 1 278 CALIBRATION N/A RED CALIBRATION N/A 1 279 CALIBRATION N/A RED CALIBRATION N/A 1 280 WALL GWB DARK HALL E < LOD BROWN 281 WALL GWB WHITE HALL E < LOD ehsi. 12 EHS-Inteirnational,Inc. • • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building (mg/cm2) 282 ELECTRICAL METAL WHITE HALL E < LOD PANEL 283 COAT RACK WOOD RED 605 E < LOD 284 ELECTRICAL METAL DARK HALL E < LOD PANEL GRAY 285 WHITE DRY ERASE WHITE 603 E < LOD BOARD BOARD 286 COUNTER TOP PLYWOOD BLACK 603 E < LOD 287 WALL METAL BLUE 121 E < LOD 288 DOOR FRAME METAL BEIGE 191 E < LOD 289 WALL GWB LIGHT 119 E < LOD BLUE 290 WALL GWB LIGHT 119 E < LOD BLUE 291 WALL GWB TAN 601 E < LOD 292 CONDUIT PLASTIC TAN 601 E 1.9 COVER 293 DOOR METAL TAN 602 E < LOD WINDOW FRAME 294 CONDUIT METAL TAN 602 E < LOD COVER 295 ELECTRICAL METAL TAN 602 E < LOD BOX 296 ELECTRICAL METAL TAN 602 E < LOD BOX 297 WALL GWB NEON 602 E < LOD GREEN 298 LOCKER METAL BLUE HALL E < LOD 299 DOOR FRAME WOOD BLACK 607 THEATER E < LOD 300 WALL GWB BLACK 607 THEATER E < LOD 301CONDUIT METAL BLACK 607 THEATER E 0.2 PIPE 302 ELECTRICAL METAL BLACK 607 THEATER E < LOD BOX 303 WINDOW SILL WOOD TAN 607 THEATER E 0.04 304 WINDOW WOOD TAN 607 THEATER E < LOD FRAME 305 LOWER WOOD GRAY 607 THEATER E < LOD STAGE FLOOR 306 STAGE STEPS WOOD BLACK 607 THEATER E < LOD 307 MAIN STAGE WOOD RED 607 THEATER E < LOD FLOOR 308 MAIN STAGE WOOD RED 607 THEATER E < LOD FLOOR e si.. EHS-International,Inc. 12 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building (mg/cm2) 309 MAIN STAGE WOOD BLACK 607 THEATER E < LOD FLOOR 310 121N SACT ACT BLACK 607 THEATER E < LOD ON WALL 311 12IN SACT ACT BLACK 607 THEATER E < LOD ON WALL 312 12IN SACT ACT BLACK 607 THEATER E < LOD ON WALL 313 RAILING METAL BLUE HALL E < LOD 314 WALL GWB LIGHT WOMEN E 0.07 GREEN BATHROOM 315 TRIM WOOD DARK MEN E < LOD PURPLE BATHROOM 316 WALL GWB DARK WOMEN E 0.07 PURPLE BATHROOM 317 COVE BASE CERAMIC WHITE WOMEN E 14.3 TILE BATHROOM 318 FLOOR CERAMIC GRAY WOMEN E < LOD TILE BATHROOM 319 FLOOR CERAMIC GRAY WOMEN E < LOD TILE BATHROOM 320 STALLS PLYWOOD DARK WOMEN E < LOD PURPLE BATHROOM 321 SPLASHGUA CERAMIC WHITE WOMEN E 16.2 RD WALL TILE BATHROOM 322 WALL GWB LIGHT BOYS E < LOD GREEN BATHOOM _ 323 WALL TRIM WOOD DARK BOYS E < LOD GREEN BATHOOM 324 WALL METAL DARK BOYS E < LOD GREEN BATHOOM _ 325 COVE BASE CERAMIC WHITE BOYS E 15.4 TILE BATHOOM 326 WALL PLYWOOD DARK BOYS E < LOD GREEN BATHOOM 327 WALL PLYWOOD DARK BOYS E < LOD GREEN BATHOOM 328 FLOOR CERAMIC GRAY BOYS E < LOD TILE BATHOOM _ 329 SPLASHGUA CERAMIC OFF BOYS E 15.7 RD WALL TILE WHITE BATHOOM 330 SPLASHGUA CERAMIC OFF BOYS E 15.2 RD WALL TILE WHITE BATHOOM 331 STALL PLYWOOD OFF BOYS E < LOD WHITE BATHOOM 332 PIPE CHASE METAL GRAY BOYS E < LOD DOOR BATHOOM _ 333 WINDOW SILL CERAMIE RED 609 E < LOD ehs/.ii EHS-International,Inc. 1 L • 0 Limited Hazardous Materials Survey Report Federal Way High School • EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. # (mg/Cm2) TILE 334 WALL WOOD LIGHT THEATER E 0.04 panels BLUE BREAK RM 335 CABINETS PLYWOOD LIGHT THEATER E 0.25 GREEN BREAK RM 336 COUNTER PLYWOOD BLUE THEATER BK E < LOD RM DRESSING 337 COUNTER PLYWOOD BLUE THEATER BK E < LOD RM DRESSING 338 COUNTER PLYWOOD BLUE THEATER BK E < LOD RM DRESSING 339 COUNTER PLYWOOD BLUE THEATER BK E < LOD RM DRESSING 340 CABINET PLYWOOD LIGHT 611 F < LOD GREEN 341 CONDUIT METAL LIGHT 611 F 0.2 COVER TAN 342 DOOR METAL TAN 611 F < LOD WINDOW FRAME 343 DOOR METAL TAN 611 F < LOD WINDOW FRAME 344 CABINET PLYWOOD LIGHT 611 F 0.05 BLUE 345 WALL GWB TAN 613 F < LOD 346 WALL PLASTER DARK BOYS F < LOD BROWN RESTROOM 347 WALL PLASTER PEACH BOYS F 0.08 RESTROOM 348 COVE BASE CERAMIC TAN BOYS F 8.9 TILE RESTROOM 349 FLOOR CERAMIC BROWN BOYS F < LOD TILE RESTROOM 350 STALL PLYWOOD DARK BOYS F < LOD BLUE RESTROOM 351 RADIATOR METAL OFF BOYS F < LOD WHITE RESTROOM 352 WALL WOOD OFF 404 F < LOD PANEL WHITE 353 DOOR FRAME METAL DARK 404 F < LOD BLUE 354 WALL WOOD DARK HALL F < LOD GRAY 355 WALL GWB LIGHT OFFICE BTWN F < LOD BLUE 403&405 356 DOOR FRAME METAL TAN OFFICE BTWN F < LOD 403&405 ehsi4 EHS-International,Inc. 13 S • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. # (mg/cm2) 357 DOOR FRAME METAL TAN OFFICE BTWN F < LOD 403&405 358 WALL WOOD LIGHT HALL F < LOD BLUE 359 RAILING METAL DARK HALL F < LOD BLUE 360 LOCKER METAL DARK HALL F < LOD BLUE 361 ELECTRICAL METAL TAN MECH RM F < LOD PANEL 362 WALL PLASTER TAN MECH RM F < LOD 363 MECH EQUIP METAL BLUE MECH RM F < LOD 364 MECH EQUIP METAL BLUE MECH RM F < LOD 365 WATER METAL YELLOW MECH RM F 0.03 HEATER 366 WALL GWB WHITE HALL F 0.1 367 CEILING WOOD TAN 401 F < LOD 368 CEILING WOOD TAN 401 F < LOD 369 CEILING WOOD TAN 401 F < LOD 370 CALIBRATION N/A RED CALIBRATION CALIBRATIO 1.4 N 371 CALIBRATION N/A RED CALIBRATION CALIBRATIO 0.9 N 372 CALIBRATION N/A RED CALIBRATION CALIBRATIO 0.9 N 373 CALIBRATION N/A RED CALIBRATION CALIBRATIO 1 N 374 CALIBRATION N/A RED CALIBRATION CALIBRATIO < LOD N 375 CALIBRATION N/A RED CALIBRATION CALIBIRATIO 0.9 N 376 CALIBRATION N/A RED CALIBRATION CALIBRATIO 0.9 N 377 SELF- N/A SELF- SELF- 2.35 CALIBRATION CALIBRATION CALIBRATIO N 378 CALIBRATION N/A RED CALIBRATION CALIBRATIO 1 N 379 CALIBRATION N/A RED CALIBRATION CALIBRATIO 1 N 380 CALIBRATION N/A RED CALIBRATION CALIBRATIO 0.9 N 381 CALIBRATION N/A RED CALIBRATION CALIBRATIO 1 N 382 WALL GWB TAN 506 G < LOD etiSi 44I, EHS-International,Inc. ! 0 Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. # (mg/cm2) 383 WALL BRICK ORANGE 500 BOYS RR G < LOD 384 COVE BASE CERAMIC BURGUN 500 BOYS RR G 0.06 TILE DY 385 COVE BASE CERAMIC BURGUN 500 BOYS RR G 0.04 TILE DY 386 WALL GWB ORANGE 500 BOYS RR G < LOD 387 COVE BASE CERAMIC WHITE 500 BOYS RR G 14.6 TILE 388 WALL BRICK, HOLE ORANGE 500 BOYS RR G < LOD PTRN 389 WALL BRICK, HOLE ORANGE 500 BOYS RR G < LOD PTRN 390 FLOOR CERAMIC BROWN 500 BOYS RR G < LOD TILE 391 STALL PLYWOOD DARK 500 BOYS RR G < LOD BLUE 392 WALL GWB LIGHT HALL G < LOD BLUE 393 WINDOW WOOD TAN HALL G < LOD FRAME 394 WALL GWB LIGHT 500 G < LOD YELLOW 395 CONDUIT METAL TAN 502 G < LOD COVER 396 CONDUIT METAL TAN 502 G < LOD COVER 397 DOOR FRAME METAL TAN 502 G < LOD 398 WALL GWB LIGHT 502 G < LOD BLUE 399 LOCKERS METAL DARK HALL G < LOD BLUE 400 PIPE, RAIN METAL TAN 501 STORAGE G < LOD 401 ELECTRICAL METAL TAN JANITOR G < LOD PANEL CLOSET 402 SPLASHGD CERAMIC PEACH HALL G 12.3 AT DRNK TILE FTN 403 WALL GWB WHITE 508 G < LOD 404 DOOR METAL TAN 505 G < LOD WINDOI FRAME 405 EXTERIOR METAL TAN HALL G < LOD DOOR 406 EXTERIOR METAL TAN HALL G < LOD DOOR 407 DOOR FRAME METAL TAN 508 G < LOD ehsi♦a EHS-International.Inc. 13 • • , Limited Hazardous Materials Survey Report Federal Way High School ^ EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. ) 408 RAILING METAL DARK HALL G < LOD BLUE 409 WALL GWB TAN JANITOR G < LOD CLOSET 410 CALIBRATION N/A RED CALIBRATION N/A 0.9 411 CALIBRATION N/A RED CALIBRATION N/A 1 412 CALIBRATION N/A RED CALIBRATION N/A 1 413 CALIBRATION N/A CALIBRATION N/A 2.55 414 CALIBRATION N/A RED CALIBRATION N/A < LOD 415 CALIBRATION N/A RED CALIBRATION N/A < LOD 416 CALIBRATION N/A CALIBRATION N/A 2.47 417 SELF- N/A RED SELF- N/A 1 CALIBRATION CALIBRATION 418 CALIBRATION N/A RED CALIBRATION N/A 1 419 CALIBRATION N/A RED CALIBRATION N/A 1 420 CALIBRATION N/A RED CALIBRATION N/A 1 421 CALIBRATION CERAMIC BLUE CALIBRATION COMUNITY < LOD POOL 422 WALL CERAMIC WHITE BOYS COMUNITY 9.6 LOCKER POOL 423 COVE BASE CERAMIC WHITE BOYS COMUNITY 8.9 LOCKER POOL 424 SHOWER CERAMIC BROWN BOYS COMUNITY 13.5 STALL LOCKER POOL 425 COLUMN GWB LIGHT POOL AREA COMIJNITY < LOD YELLOW POOL 426 EXTERIOR METAL BLUE POOL AREA COMUNITY < LOD DOOR FRAME POOL 427 EXTERIOR METAL BLUE POOL AREA COMIJNITY < LOD DOOR POOL 428 WALL GWB YELLOW POOL AREA MANAGER < LOD OFFICE 429 WALL GWB LIGHT OFFICE COMMUNIT 0.05 BLUE Y POOL 430 WALL CERAMIC LIGHT MENS RR COMMUNI 5.7 TILE BROWN TY POOL 431 DOOR METAL BLACK ENTRYWAY COMMUNIT < LOD Y POOL 432 WINDOW,DO METAL BLACK ENTRYWAY COMMUNIT < LOD OR FRAME Y POOL 433 SMALL TILE, CERAMIC GRAY POOL AREA COMMUNIT < LOD POOL Y POOL PERIMETER 434 FLOOR CERAMIC YELLOW WOMEN COMMUNIT < LOD LOCKER Y POOL ehs WS EHS-International.Inc. 1 3 • i Limited Hazardous Materials Survey Report Federal Way High School ' EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building (mg/cm2) 435 WALL GWB LIGHT STAFF WOMEN COMMUNIT < LOD YELLOW LOCKER Y POOL 436 WALL CONCRETE OFF POOL COMMUNIT < LOD WHITE INTERIOR Y POOL 437 WALL AT CERAMIC OFF POOL COMMUNIT < LOD FILTER TILE WHITE INTERIOR Y POOL OPENINGS 438 WALL AT CERAMIC OFF POOL COMMUNI 10.8 FILTER TILE WHITE INTERIOR TY POOL OPENINGS 439 DIVING METAL BEIGE POOL COMMUNIT < LOD BOARD Y POOL SUPPORT 440 AHU METAL LIGHT BOILER RM COMMUNIT 0.13 GREEN Y POOL 441 WALL CONCRETE DARK BOILER RM COMMUNIT < LOD GRAY OFFICE Y POOL 442 ELECTRICAL METAL GRAY BOILER RM COMMUNIT < LOD PANEL OFFICE Y POOL 443 WALL BRICK LIGHT BOILER RM COMMUNIT < LOD YELLOW OFFICE Y POOL 444 BOILER METAL BLACK BOILER RM COMMUNIT < LOD Y POOL 445 FLOOR CONCRETE LIGHT BOILER RM COMMUNIT 0.04 GRAY Y POOL 446 PIPE, COLD METAL LIGHT BOILER RM COMMUNIT < LOD WATER GREEN Y POOL 447 HAND RAIL METAL DARK BOILER RM COMMUNIT 0.7 GREEN Y POOL 448 TANK METAL LIGHT BOILER RM COMMUNIT < LOD GREEN Y POOL 449 TANK METAL LIGHT BOILER RM COMMUNIT < LOD GREEN Y POOL 450 TANK METAL LIGHT BOILER RM COMMUNIT < LOD GREEN Y POOL 451 TANK, LOWER CONCRETE LIGHT BOILER RM COMMUNIT 0.05 LEVEL GRAY Y POOL 452 PIPE METAL BLUE BOILER RM COMMUNI 1.4 TY POOL 453 DUCTWORK METAL SILVER BOILER RM COMMUNIT < LOD Y POOL 454 WALL GWB TAN POOL AREA COMMUNIT < LOD Y POOL 455 WALL CONCRETE RED EXTERIOR, S COMMUNIT < LOD Y POOL 456 METAL METAL SILVER EXTERIOR, S COMMUNIT < LOD COVERED Y POOL PIPES ehSla•, EHS-International,Inc. 13 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. _ # — (mg/cm2) 457 SIDING BRICK LIGHT EXTERIOR, E COMMUNIT < LOD BROWN Y POOL 458 FENCE METAL DARK EXTERIOR, N COMMUNIT 0.5 BROWN Y POOL 459 SELF- N/A N/A CALIBRATION N/A 2.46 CALIBRATION 460 CALIBRATION N/A RED CALIBRATION N/A 1 461 CALIBRATION N/A RED CALIBRATION N/A 1 462 CALIBRATION N/A RED CALIBRATION N/A 1 463 CALIBRATION N/A RED CALIBRATION N/A 1 464 WALL PLASTER OFF 407 J < LOD WHITE 465 DOOR FRAME METAL TAN 407 J < LOD 466 WALL GWB WHITE 407 J < LOD 467 CEILING WOOD BEAM TAN 407 J < LOD 468 CEILING WOOD BEAM TAN 407 J < LOD 469 WINDOW SILL CERAMIC BURGUN 407 J < LOD TILE DY 470 WALL WOOD GRAY HALL J < LOD PANEL 471 WALL GWB WHITE HALL J < LOD 472 HAND RAIL METAL DARK HALL J < LOD BLUE 473 WALL GWB LIGHT 406 J < LOD BLUE 474 CONDUIT METAL LIGHT 406 J 0.03 COVER BLUE 475 DOOR METAL TAN 406 J < LOD WINDOW FRAME 476 WINDOW WOOD TAN 408 J < LOD TRIM 477 CONDUIT METAL TAN 408 J < LOD COVER 478 LOCKER METAL DARK HALL J < LOD BLUE 479 WALL METAL YELLOW 409 J 0.1 480 CEILING SACT WHITE 411 J < LOD 481 WALL PLASTER DARK 410 J 0.05 BLUE 482 WALL GWB DARK 410 J 0.05 RED 483 WALL GWB DARK 410 J 0.09 RED ehsie,6 EHS-International,Inc. 13 i • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. ) 484 RAIN PIPE FIBERGLASS TAN JANITOR J 0.08 CLOSET 485 ELECTRICAL METAL TAN HALL J < LOD PANEL 486 COVE BASE CERAMIC TAN GIRLS 3 8.4 TILE BATHROM 487 FLOOR CERAMIC TAN GIRLS J < LOD TILE BATHROM 488 STALL WOOD DARK GIRLS J < LOD BLUE BATHROM 489 RADIATOR METAL TAN GIRLS J 0.04 BATHROM 490 DOOR FRAME METAL TAN STORAGE K < LOD 491 WALL GWB TAN STORAGE K < LOD 492 RADIATOR METAL TAN STORAGE K < LOD 493 PIPE METAL TAN STORAGE K < LOD 494 ELECTRICAL METAL GRAY STORAGE K 0.07 BOX 495 LADDER METAL TAN STORAGE K 0.08 496 CEILING GWB TAN STORAGE K < LOD 497 CEILING GWB TAN STORAGE K < LOD 498 WALL WOOD DARK HALL K < LOD GRAY 499 HAND RAIL METAL DARK HALL K 0.05 BLUE 500 WALL GWB WHITE HALL K 0.17 501 DOOR FRAME METAL BURGUN 413 K < LOD DY 502 WALL GWB WHITE 413 K < LOD 503 WALL GWB TEAL 413 K < LOD 504 CONDUIT METAL TEAL 413 K < LOD COVER 505 CONDUIT METAL TEAL 413 K < LOD COVER 506 WINDOW SILL CERAMIC BURGUN 413 K < LOD TILE DY 507 LOCKERS METAL DARK HALL K < LOD BLUE 508 ACT ON WALL ACT WHITE 415 K < LOD 509 ACT ON WALL ACT WHITE 415 K < LOD 510 ACT ON WALL ACT WHITE 415 K < LOD 511 CEILING SACT WHITE 415 K < LOD 512 WALL GWB TAN 415 K 0.07 ehs14.0 EHS-International,Inc. 13 0 • , Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. Component Substrate Color Room Building z # _ _ (mg/cm ) 513 ELECTRICAL METAL TAN 415 K < LOD PANEL 514 CEILING WOOD LIGHT 417 K < LOD BLUE 515 CONDUIT METAL LIGHT 417 K < LOD COVER BLUE 516 WALL GWB LIGHT 417 K < LOD BLUE 517 WALL GWB YELLOW 416 K < LOD 518 DOOR METAL TAN HALL K < LOD 519 WINDOW METAL TAN HALL K < LOD FRAME 520 WALL WOOD WHITE HALL K < LOD 521 DOOR METAL DARK HALL H < LOD BROWN 522 DOOR FRAME METAL DARK HALL H < LOD BROWN 523 WALL GWB OFF HALL H < LOD WHITE 524 FIRE METAL OFF HALL H < LOD EXTINGUISHE WHITE R CABINET 525 FIRE METAL OFF HALL H < LOD EXTINGUISHE WHITE R CABINET 526 DOOR METAL DARK 705 H < LOD WINDOW BROWN FRAME 527 FUME HOOD METAL TAN 705 H < LOD 528 WINDOW METAL DARK 705 H < LOD FRAME BROWN 529 CONDUIT METAL OFF 704 H < LOD COVER WHITE 530 WINDOW CERAMIC TAN 704 H 15.2 SILL 531 LOCKERS METAL LIGHT HALL H < LOD BLUE 532 WALL GWB neon 703 H 0.6 green 533 WALL GWB neon 703 H 0.5 green _ 534 WALL GWB BLUE 703 H < LOD 535 SINK PLASTER BLACK TEACHER H < LOD BREAK RM _ 536 COVE BASE CERAMIC TAN 706 H < LOD 537 FLOOR CERAMIC TAN- 706 H < LOD ehs/•) 1 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. (mg/cm2) GRAY 538 WALL GWB LIGHT 706 H < LOD YELLOW 539 ELECTRICAL METAL GRAY HALL H < LOD PANEL 540 WALL GWB YELLOW GIRLS BATH H < LOD 541 WALL GWB ORANGE BOYS BATH H < LOD 542 DOOR METAL TAN HALL L < LOD 543 DOOR FRAME METAL TAN HALL L < LOD 544WALL CMU WHITE HALL L < LOD 545 WALL CMU WHITE HALL L < LOD 546 WALL WOOD DARK 311 L < LOD PANEL BLUE 547 WINDOW SILL WOOD OFF 311L < LOD WHITE 548 WINDOW SILL WOOD OFF 311L < LOD WHITE 549 WINDOWSILL WOOD OFF 311 L < LOD WHITE 550 WINDOW SILL WOOD OFF 311 L < LOD WHITE 551 WINDOW METAL OFF 311 L < LOD FRAME WHITE 552 DOOR FRAME METAL TAN 312L < LOD 553 DOOR FRAME METAL TAN 312 L < LOD 554 WALL BRICK OFF 312 L < LOD WHITE 555 PIPE METAL OFF 312 L < LOD WHITE 556 ELECTRICAL METAL GRAY 312 L < LOD PANEL 557 COLUMN CONCRETE OFF 312 L < LOD WHITE 558 FLOOR CONCRETE GRAY 312 L 0.06 559 WALL GWB OFF 312 L < LOD WHITE 560 LOCKER METAL BLUE 312 L < LOD 561 STAIRS WOOD OFF 312 L 1.1 WHITE 562 CEILING METAL RED 312 L 1.2 563 FLOOR CONCRETE RED 310 L < LOD 564 WALL CMU LIGHT 310 L 0.17 YELLOW e s EHS-International,Inc. 13 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 ` July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building (mg/cm2 565 LOCKER METAL BLUE 310 L. < LOD 566 WINDOW METAL TAN 310 L. < LOD FRAME 567 WINDOW METAL TAN 310 L < LOD FRAME 568 HANDRAIL METAL RED 310 L. < LOD 569 ELECTRICAL METAL GRAY 310 L < LOD PANEL 570 GARAGE METAL OFF 310 L < LOD DOOR WHITE 571 LOCKER METAL GRAY 310 L < LOD 572 DISPLAY METAL TAN HALL L < LOD WINDOW FRAME 573 DRINKING CERAMIC GRAY HALL L < LOD FTN SPLASHGUAR D 574 FIRE EXT METAL OFF HALL L < LOD CABINET WHITE 575 DOOR FRAME METAL DARK 308 L < LOD GRAY 576 WALL CMU BROWN 308 L 0.12 577 WALL CMU LIGHT 308 L 0.3 BLUE 578 CEILING ACT WHITE 308 L 0.4 579 WALL CONCRETE YELLOW 308 L < LOD 580 LOCKER METAL BLUE 308 L < LOD 581 CALIBRATION N/A RED CALIBRATION N/A 1.8 582 CALIBRATION N/A RED CALIBRATION N/A 1 583 CALIBRATION N/A RED CALIBRATION N/A 0.9 584 CALIBRATION N/A RED CALIBRATION N/A 1 585 SELF- N/A SELF- N/A 2.72 CALIBRATION CALIBRATION 586 CALIBRATION N/A RED CALIBRATION N/A 1 587 CALIBRATION N/A RED CALIBRATION N/A 0.9 588 CALIBRATION N/A RED CALIBRATION N/A 0.9 589 WALL GWB TAN 306 M 0.13 INSRUMENT STORAGE 590 WALL ACT WHITE 306 M < LOD INSRUMENT STORAGE e 5 i 4 14 EHS-International,Inc. 0 • Limited Hazardous Materials Survey Report Federal Way High School ' EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. Component Substrate Color Room Building Z # (mg/cm2) 591 DOOR FRAME METAL DARK 306 M < LOD BLUE INSRUMENT STORAGE 592 DOOR METAL TAN 306 M < LOD WINDOW INSRUMENT FRAME STORAGE 593 WALL GWB GREEN 306 PRACTICE M < LOD RM 2 594 WALL GWB LIGHT 306 M 0.12 BLUE INSTRUMENT STORAGE 595 DOOR FRAME WOOD TAN 306 DIRECTOR M < LOD OF BANDS 596 DOOR FRAME METAL TAN HALL M < LOD 597 DOOR FRAME METAL TAN HALL M 0.08 598 DOOR METAL TAN HALL M < LOD 599 DOOR METAL BLACK HALL M < LOD WINDOW FRAME 600 WALL BRICK WHITE HALL M < LOD 601 FIRE EXT METAL WHITE HALL M < LOD CABINET 602 WINDOW METAL WHITE HALL M 0.03 FRAME 603 DOOR TO METAL TAN 305 M < LOD WINDOW DISPLAY 604 WALL GWB LIGHT 305 M 0.04 GRAY 605 CONDUIT METAL TAN 305 M < LOD COVER 606 TRIM, WALL CONCRETE TAN 305 M < LOD 607 WALL CMU LIGHT 305 M 0.14 TAN 608 WALL METAL WHITE HALL M < LOD 609 WALL WOOD LIGHT 307 M < LOD DISPLAY BLUE BOARD 610 PIPE METAL TAN 307 M < LOD 611 PIPE METAL TAN 307 M < LOD 612 ELECTRICAL METAL LIGHT 307 M < LOD PANEL BLUE 613 FLAMMABLES METAL YELLOW 307, M 0.7 STRG CBNT CHEMICAL STORAGE ehsi 4 EHS-International,Inc. 14 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. # (mg/cm ) 614 CHEM METAL RED 307, M 0.09 STORAGE CHEMICAL CABINET STORAGE 615 CORROSIVES METAL DARK 307, NI < LOD STRG CBNT BLUE CHEMICAL STORAGE 616 LOCKER METAL DARK HALL M < LOD BLUE 617 WALL GWB OFF 304 M 0.08 WHITE 618 WALL CONCRETE OFF 304 M 0.15 WHITE 619 WALL TRIM METAL BURGUN 304 M 0.09 DY 620 HAND RAIL METAL TAN 304 N 0.26 621 PIPE METAL TAN MECH RM NI 0.5 622 BOILER METAL BLUE MECH RM NI < LOD CASING 623 BOILER METAL BLUE MECH RM NI < LOD CASING 624 DUCT METAL TAN MECH RM NI < LOD 625 ELECTRICAL METAL GRAY MECH RM Ni < LOD PANEL 626 WALL BRICK TAN MECH RM NI < LOD 627 WALL CMU WHITE HALL Ni < LOD 628 FLOOR CERAMIC PINK GIRLS Ni < LOD TILE BATHROOM 629 WALL CERAMIC PEACH GIRLS M 15.5 TILE BATHROOM 630 WALL, CERAMIC GRAY HALL M < LOD DRINKING TILE FTN SPLASH 631 DRINKING CERAMIC WHITE HALL M 29.1 FTN 632 FLOOR CERAMIC LIGHT BOYS Ni < LOD BLUE BATHROOM 633 WALL CERAMIC GRAY BOYS M 12 BATHROOM 634 SINK CERAMIC WHITE BOYS M 28.7 BATHROOM 635 STALL METAL LIGHT BOYS NI < LOD BLUE BATHROOM 636 URINAL METAL WHITE BOYS NI < LOD BATH ROOM 637 WATER METAL YELLOW STORAGE BY NI 0.03 HEATER BOYS BATH (' . .s .. EHS-International,Inc. 14 . . • 410 Limited Hazardous Materials Survey Report Federal Way High School ' EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building (mg/cm2) 638 TOILET CERAMIC WHITE GIRLS M 5.6 BATHROOM 639 TOILET CERAMIC WHITE 500 BOYS G 5.7 BATH 640 SINK CERAMIC WHITE 500 BOYS G 26.8 BATH 641 DRINKING CERAMIC WHITE HALL G < LOD FTN 642 SINK CERAMIC WHITE MENS BATH F 28 643 URINAL CERAMIC WHITE MENS BATH F 0.03 644 TOILET, WALL CERAMIC WHITE MENS BATH F < LOD FASTENED 645 DRINKING CERAMIC WHITE HALL L 37 FTN 646 WALL GWB LIGHT 316 N 0.04 YELLOW 647 DOOR WOOD DARK 316 N 0.9 FRAME BLUE 648 DOOR WOOD DARK 316 N 1.4 BLUE 649 WINDOW SILL WOOD TAN 316 N 0.6 650 CEILING WOOD BEAM DARK 316 N < LOD BLUE 651 WALL WOOD BURGUN 316 N 0.14 DY 652 WINDOW WOOD WHITE 316 N 0.21 FRAME 653 CEILING GWB WHITE 316 N 0.07 654 ELECTRICAL METAL DARK 316 N 0.12 PANEL BLUE 655 CONDUIT METAL LIGHT 316 N < LOD PIPE COVER YELLOW 656 RADIATOR METAL LIGHT 316 N 0.04 GREEN 657 RADIATOR METAL LIGHT 316 N 0.07 GREEN 658 EXTERIOR WOOD TAN 316 N 1.7 WOOD SIDING 659 EXT BARRIER CONCRETE BLUE 316 N 0.5 GUARD POLE 660 EXTERIOR WOOD DARK 316 N 2.1 SIDING PURPLE TRIM 661 EXTERIOR WOOD DARK 316 N 1.8 SIDING PURPLE TRIM e st4 EHS-International.Inc. 14 • • . . Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Conc. # (mg/cm2) 662 EXTERIOR WOOD DARK 316 N 1.7 DOOR PURPLE 663 EXTERIOR WOOD DARK 316 N 0.9 DOOR FRAME PURPLE 664 EXTERIOR WOOD TAN 316 N 0.04 WOOD PANELS 665 EXTERIOR METAL LIGHT 316 N < LOD HAND RAIL GRAY 666 EXTERIOR METAL TAN 122 PORTABLE < LOD DOOR 122 667 EXTERIOR METAL TAN 122 PORTABLE < LOD DOOR FRAME 122 668 EXTERIOR WOOD TAN 122 PORTABLE < LOD SIDING 122 669 EXTERIOR WOOD TAN 122 PORTABLE < LOD ENTRYWAY 122 FLOOR 670 EXTERIOR WOOD DARK 122 PORTABLE < LOD TRIM BROWN 122 671 EXTERIOR WOOD DARK 122 PORTABLE < LOD TRIM BROWN 122 672 EXTERIOR WOOD TAN 122 PORTABLE < LOD WOOD 122 PANELS 673 EXT RAIN METAL WHITE 122 PORTABLE < LOD PIPE 122 FASTENER 674 EXT RAIN METAL WHITE 122 PORTABLE < LOD PIPE 122 FASTENER 675 WALL GWB OFF 122 PORTABLE < LOD WHITE 122 676 DOOR WOOD DARK 122 PORTABLE < LOD BROWN 122 677 DOOR FRAME WOOD DARK 122 PORTABLE < LOD BROWN 122 678 WALL PANEL WOOD OFF 122 PORTABLE < LOD WHITE 122 679 CEILING SACT WHITE 122 PORTABLE < LOD 122 680 CORNER METAL WHITE EXTERIOR M 0.03 GUARD 681 CONCRETE CONCRETE WHITE EXTERIOR M < LOD PILLAR 682 METAL METAL DARK EXTERIOR M 0.14 SUPPORT BLUE POLE ehsi 14 EH$-International,Inc. s • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Component Substrate Color Room Building Lead Cont. # (mg/cm2) 683 METAL METAL DARK EXTERIOR M 0.13 SUPPORT BLUE POLE 684 DOOR METAL DARK EXTERIOR M < LOD BLUE 685 DOOR FRAME METAL DARK EXTERIOR M 0.05 BLUE 686 FIRE EXT CONCRETE RED EXTERIOR M < LOD INDICATOR 687 TRANSF CONCRETE YELLOW EXTERIOR M < LOD BARRIER POLE 688 TRANSFORME PLASTER LIGHT EXTERIOR M 0.06 R CABINET GREEN 689 DOOR METAL LIGHT EXTERIOR L < LOD GRAY 690 DOOR FRAME METAL LIGHT EXTERIOR L < LOD GRAY 691 DOOR FRAME METAL LIGHT EXTERIOR L < LOD GRAY 692 GARAGE CONCRETE LIGHT EXTERIOR L 0.05 DOOR FRAME GRAY 693 GARAGE CONCRETE LIGHT EXTERIOR L 0.04 DOOR FRAME GRAY 694 GARAGE METAL LIGHT EXTERIOR L < LOD DOOR GRAY 695 BARRIER CONCRETE YELLOW EXTERIOR L 3.1 GUARD 696 SIDING BRICK BROWN EXTERIOR L < LOD 697 SIDING CMU BROWN EXTERIOR L < LOD 698 GARAGE WOOD WHITE EXTERIOR L < LOD DOOR FRAME 699 SIDING BRICK WHITE EXTERIOR L < LOD 700 SIDING CMU WHITE EXTERIOR L < LOD 701 SIDING CMU TAN EXTERIOR L < LOD 702 SIDING TRIM WOOD TAN EXTERIOR F < LOD 703 PARK LOT METAL YELLOW EXTERIOR F 0.5 ENTRY GATE 704 FIRE CONCRETE YELLOW EXTERIOR F < LOD HYDRANT 705 OVERHANG METAL BEIGE EXTERIOR H < LOD SUPPORT 706 OVERHANG METAL BEIGE EXTERIOR H < LOD SUPPORT 707 RAIN PIPE METAL BEIGE EXTERIOR H < LOD 708 DOOR METAL BEIGE EXTERIOR H < LOD ehsi 4 EHS-International,Inc. 14 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building (mg/cm2) 709 DOOR FRAME METAL BEIGE EXTERIOR H < LOD 710 SIDING CONCRETE OFF EXTERIOR G < LOD WHITE 711 HAND RAILS METAL DARK EXTERIOR G < LOD BLUE 712 PERIMETER CONCRETE OFF EXTERIOR E < LOD FOUNDATION WHITE _ 713 RAIN PIPE METAL BROWN EXTERIOR E 0.4 714 SIDING CONCRETE LIGHT EXTERIOR E < LOD GRAY 715 SIDING CONCRETE OFF EXTERIOR A2 < LOD WHITE 716 SIDING CONCRETE OFF EXTERIOR A2 < LOD WHITE 717 OVERHANG METAL GRAY EXTERIOR C 0.9 SUPPORT 718 WALKWAY CONCRETE OFF EXTERIOR C < LOD COLUMNS WHITE 719 CALIBRATION N/A RED CALIBRATION N/A < LOD 720 CALIBRATION N/A RED CALIBRATION N/A 1.2 721 CALIBRATION N/A RED CALIBRATION N/A 0.9 722 CALIBRATION N/A RED CALIBRATION N/A 1 723 CALIBRATION N/A RED CALIBRATION N/A 1 724 SELF- N/A N/A SELF- N/A 2.64 CALIBRATION CALIBRATION 725 CALIBRATION N/A RED CALIBRATION N/A 1 726 CALIBRATION N/A RED CALIBRATION N/A 0.9 727 CALIBRATION N/A RED CALIBRATION N/A 1 728 CALIBRATION N/A RED CALIBRATION N/A 1 729 CALIBRATION N/A RED CALIBRATION N/A 1 730 CALIBRATION N/A RED CALIBRATION N/A 1 731 CALIBRATION N/A RED CALIBRATION N/A 1 732 CALIBRATION N/A RED CALIBRATION N/A 1 733 SIDING STUCCO WHITE EXTERIOR, S :I 1.2 734 WALKWAY METAL WHITE EXTERIOR BETWEEN J < LOD COVER AND H SUPPORT 735 PICNIC TABLE WOOD DARK EXTERIOR BETWEEN F < LOD BLUE AND G 736 SHED WOOD TAN EXTERIOR F < LOD 737 SHED DOOR WOOD DARK EXTERIOR F < LOD BLUE ehSi.. EHS-International,Inc. 14 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building (mg/cm2) 738 LOWER CONCRETE WHITE EXTERIOR HALL < LOD SIDING BETWEEN F&G 739 LOWER CONCRETE WHITE EXTERIOR HALL 1.3 SIDING BETWEEN F&G 740 WINDOW SILL METAL DARK EXTERIOR HALL < LOD BROWN BETWEEN F&G 741 WINDOW METAL DARK EXTERIOR HALL < LOD FRAME BROWN BETWEEN F&G 742 SIDING STUCCO WHITE EXTERIOR, N E 1.3 743 SITTING WOOD REDDISH EXTERIOR, E < LOD BENCH BROWN COURTYARD 744 CEILING METAL OFF EXT, COVERED D < LOD WHITE WALKWAY 745 CEILING METAL OFF EXT, COVERED D < LOD WHITE WALKWAY 746 CEILING METAL OFF EXT, COVERED D 0.07 WHITE WALKWAY 747 HAND RAIL METAL PURPLE EXTERIOR, W D 0.09 748 SUPPORT WOOD OFF EXT, W D < LOD BEAM,CEILIN WHITE COVERED G WALKWY 749 SUPPORT WOOD OFF EXT, W D < LOD BEAM,CEILIN WHITE COVERED G WALKWY 750 TILT UP CONCRETE OFF EXTERIOR, L < LOD SIDING WHITE EAST 751 WELL, LAWN WOOD WHITE EXTERIOR, M < LOD DECORATION SOUTH 752 PIPE METAL GRAY EXTERIOR, C < LOD WEST 753 SIDING CONCRETE OFF EXTERIOR, C < LOD WHITE WEST 754 SIDING CONCRETE OFF EXTERIOR, C < LOD WHITE WEST 755 SIDING CONCRETE OFF EXTERIOR, C 1.4 WHITE WEST 756 SIDING, CONCRETE DARK EXTERIOR, C < LOD LOWER BLUE WEST PERIMETER 757 SIDING, CONCRETE DARK EXTERIOR, C < LOD LOWER BLUE WEST PERIMETER 758 PICNIC TABLE METAL ARMY EXTERIOR, C < LOD GREEN WEST e si4 EHS-International,Inc. 14 • • t Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 3 XRF SAMPLING SUMMARY OF PAINTED COMPONENTS AND MATERIALS FEDERAL WAY HIGH SCHOOL Read. Lead Conc. # Component Substrate Color Room Building (mg/cm2) 759 PICNIC TABLE METAL ARMY EXTERIOR, C; < LOD GREEN WEST 760 HAND RAILS METAL DARK EXTERIOR BETWEEN 1.4 GRAY B AND M 761 HAND RAILS METAL DARK EXTERIOR BETWEEN B < LOD GRAY AND M 762 HAND RAILS METAL DARK EXTERIOR BETWEEN B 1 GRAY AND M 763 HAND RAILS METAL DARK EXTERIOR BETWEEN B 1 GRAY AND M 764 CALIBRATION N/A RED CALIBRATION N/A 1 765 CALIBRATION N/A RED CALIBRATION N/A 1 766 CALIBRATION N/A RED CALIBRATION N/A 1 Key: LOD=Limit of Detection Table 4 summarizes bulk QA lead samples, including sample number, material description, substrate, color, location, and analytical results. Copies of the analytical laboratory report and field data forms for lead paint are included in Appendix B of this report. TABLE 4 SUMMARY OF LEAD BULK QA SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE RESULTS NUMBER LOCATION COMPONENT SUBSTRATE COLOR % Pb by WT Block Al Auxiliary Wall Concrete Beige 0.0075 10527-L01 Gym (XRF #5) Block A2 Boys Locker Wall CMU Gray 0.0074 10527-L02 Room (XRF #19) . Block A2 Boys Locker Room Staff Restroom Floor Concrete Beige <0.0036 10527-L03 (XRF #41) Block A2 Boys Locker Room Staff Restroom Wall Concrete White/White 0.0310 10527-L04 (XRF #42) Block B Cafeteria Wood Column Wood Blue on Red 0.4000 10527-L05 (XRF #89) Block B Kitchen Wall CMU White 0.0390 10527-L06 Restroom (XRF #107) Block B Cafeteria File Wall GWB White <0.0045 10527-L07 Room (XRF # ) ehsi�e EHS-International,Inc. 14 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 4 SUMMARY OF LEAD BULK QA SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE RESULTS NUMBER LOCATION COMPONENT SUBSTRATE COLOR % Pb by WT Block C 1st Floor Girls Stall Wall Metal Light Green 1.2000 10527-L08 Restroom (XRF #183) Block C 1st Floor Off- Men's Restroom (XRF Wall GWB 0.0180 White/Beige 10527-L09 #184) Block C 1st Floor Fire Alarm Closet (XRF Wall CMU Beige <0.0045 10527-L10 #187) Block C 1st Floor Boiler Room (XRF Wall Brick Beige 0.0044 10527-L11 #215) Block D Library (XRF Wall GWB Beige/White <0.0044 10527-L12 #238) Block D Room 113 Wall Brick Blue <0.0035 10527-L13 (XRF #265) Block E Hall (XRF Wall GWB White <0.0044 10527-L14 #281) Block E Room 121 Wall GWB Blue <0.0044 10527-L15 (XRF #287) Block E Room 602 Wall GWB Neon Green 0.0720 10527-L16 (XRF #297) Block F Office Between Room Door Frame Metal Tan <0.0110 10527-L17 403&405 (XRF #357) Block F Hall (XRF Wall Wood Blue <0.0045 10527-L18 #358) Block F Mechanical Wall Plaster Tan <0.0048 10527-L19 Room (XRF #362) Block G Room 506 Wall GWB Tan <0.0048 10527-L20 (XRF #382) Block G Boys Cove base Ceramic Tile White 0.0140 10527-L21 Restroom (XRF #387) Block G Janitor (XRF Wall GWB Tan <0.0052 10527-L22 #409) Community Pool Men's Locker Room Wall Ceramic Tile Blue <0.0045 10527-L23 (XRF #421) Community Pool Men's Locker Room Wall Ceramic Tile Off-White <0.0040 10527-L24 (XRF #422) Block J Room 407 Wall GWB White <0.0140 10527-L25 (XRF #466) 14 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 4 SUMMARY OF LEAD BULK QA SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE RESULTS NUMBER LOCATION COMPONENT SUBSTRATE COLOR % Pb by WT Block J Room 406 Wall GWB Light Blue <0.0048 10527-L26 (XRF #473) Block K Room 415 Wall GWB Tan 0.0390 10527-L27 (XRF #512) Block K Hall (XRF Wall GWB White <0.0120 10527-L28 #520) Block H Hall (XRF Wall GWB Off-White <0.0055 10527-L29 #523) Block H Room 706 Cove Base Ceramic Tan <0.0043 10527-L30 (XRF #536) Block L Room 311 Window Sill Wood Off-White <0.0045 10527-L31 (XRF #550) Block L Room 312 Stairs Wood Off-White <0.0130 10527-L32 (XRF #561) Block M Instrument Wall ACT White <0.0061 10527-L33 Storage (XRF #590) Block M Hall (XRF Wall Brick White <0.0046 10527-L34 #600) Portable 1 Exterior Siding Wood Tan 0.0130 10527-L35 (XRF #664) Portable 2 Ceiling Ceiling SACT White <0.0048 10527-L36 (XRF #679) Block M Exterior (XRF Pillar Concrete White 0.0150 10527-L37 #681) Block L Exterior (XRF Barrier Guard Concrete Yellow 4.6000 10527-L38 #695) Block E Exterior (XRF Siding Stucco White <0.0039 10527-L39 #742) Block C Exterior (XRF Siding Concrete White 0.0490 10527-L40 #755) Key: ACT= Acoustic Ceiling Tile, CMU=Concrete Masonry Unit, GWB=Gypsum Wallboard, SACT = Suspended Acoustic Ceiling Tile, QA=Quality Assurance Bulk Sample submitted for analysis DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever paint is disturbed that has detectable quantities of lead. Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead- containing paint, the contractor should perform an initial exposure assessment to determine if personal protective measures and work practices are required. With concentrations of lead in paint ranging from 9.4 mg Pb/cm2 to <LOD and 4.5 wt% PB to <LOD, and concentrations of lead in LCM ranging from 37 mg Pb/cm2 to <LOD, it is possible that the planned work (e.g., demolition) could result in lead exposures above the DOSH action level of 30 milligram per cubic meter (mg/m3). For work on those materials with high lead concentrations as shown in 15 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 Tables 3 & 4, EHSI recommends the Contractor provided worker protection until exposure monitoring is accomplished. 2.4.3 Arsenic-Containing Building Materials EHSI also collected ten (10) Arsenic bulk mortar samples for laboratory analysis. The results of those analyses are reported in Table 5. Arsenic results for this inspection are reported in Appendix B. Table 5 summarizes Arsenic samples, including sample number, material description, substrate, color and analytical results. TABLE 5 SUMMARY OF ARSENIC BULK SAMPLING AND ANALYTICAL RESULTS FEDERAL WAY HIGH SCHOOL SAMPLE SAMPLE LOCATION COMPONENT/ COLOR RESULTS NUMBER SUBSTRATE IN PPM 10527-As-01 Community Pool-Interior Pool Brick and Brick Red/Gray <13.0 Area, south Mortar 10527-Ar-02 Community Pool-Exterior, NW Brick and Brick Red/Gray <14.0 Corner Mortar 10527-As-03 Federal Way High School, Brick and Brick Red/Gray <13.0 Block M-Exterior Mortar 10527-As-04 Federal Way High School, CMU and CMU Gray/Gray <13.0 Block L- Exterior Mortar Federal Way High School, CMU and CMU Gray/Gray- 10527-As-05 Block A-Interior Mortar Black <17.0 10527-As-06 Federal Way High School, Brick and Brick Red/Tan <18.0 Block C-Exterior Mortar 10527-As-07 Federal Way High School, Stone Block and Red/Gray <13.0 Block E-Exterior Mortar 10527-As-08 Federal Way High School, Brick and Brick Red/Gray <17.0 Block F-Exterior Mortar 10527-As-09 Federal Way High School, CMU and CMU Gray/Gray <16.0 Block M-Interior Mortar 10527-As-10 Federal Way High School, Brick and Brick Red/Pink <17.0 Block L-Exterior Mortar DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever arsenic-containing materials are disturbed. Based on the absence of arsenic identified in the sample results, EHSI does not anticipate arsenic exposures above the DOSH permissible exposure limit of 0.2 mg/m3 within an 8 hour time period. 2.4.4 Toxic Characteristic Leaching Procedure Sampling Ecology requires testing using the "toxic characteristic leachate procedure" (TCLP) and segregation of construction debris if it is potentially contaminated with dangerous waste (e.g., lead-containing paint/lead-containing materials and arsenic-containing brick mortar). Washington State Department of Ecology (Ecology) has set a dangerous waste threshold for both leachable arsenic and lead at 5.0 milligrams per liter (mg/L). ehsi.) 15 EHS-International,Inc. • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 Because the potential waste streams will be determined by the contractor, a TCLP was not conducted as part of the Limited Hazardous Materials Survey; however, based on the relatively low levels of lead and the absence of arsenic identified in the sample results, EHSI does not anticipate TCLP to fail for either arsenic or lead. If, however, the ceramic wall tiles and/or porcelain fixtures with high lead content are placed in a separate waste stream other than general construction debris, there is a strong possibility the TCLP for those waste streams may fail for high leachable lead concentrations. 2.4.5 Polychlorinated Biphenyls Ballasts EHSI inspected a representative number of each type of fluorescent fixture expected to be disturbed by the planned work for PCB-containing ballasts. The majority of the fixtures were found to contain electronic ballasts, which contain no dielectric fluid and may be disposed as construction debris. A few fixtures were found to contain magnetic ballasts and must be disposed/recycled as Ecology Dangerous Waste. A Summary of ballasts and Hg- containing light tubes is provided in Table 6. Transformers EHSI contacted Puget Sound Energy, and Engineer Annette Wilson. She stated that the transformers at Federal Way High School have already been changed out to contain PCB- free oil. 2.4.6 Mercury-Containing Fluorescent Light Tubes All fluorescent light tubes quantified in Table 6 are assumed to contain Hg. Hg wastes are regulated as "universal wastes" under Ecology's regulation WAC 173-303. Hg-containing building materials must be recycled or disposed of as hazardous waste. Hg-containing fluorescent light tubes are quantified in Table 6. TABLE 6 SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS FEDERAL WAY HIGH SCHOOL NUMBER APPROXIMATE LIGHT TYPE OF NUMBER NUMBER OF FIXTURE OF TUBES MAGNETIC S BALLASTS Block A Mounted 2'x4' Fixture w/ 6 bulbs and 2 32 192 64 PCB Magnetic Ballasts Mounted l'x4' Fixture w/ 2 bulbs and 1 12 24 12 PCB magnetic ballast Mounted l'x4' Fixture w/ 3 bulbs and 1 10 30 10 PCB magnetic ballast Recessed 2'x4' Fixture w/ 3 bulbs and 1 36 108 36 PCB magnetic Ballast ENS-International,Inc. 15 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 6 SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS FEDERAL WAY HIGH SCHOOL NUMBER APPROXIMATE LIGHT TYPE OF NUMBER NUMBER OF FIXTURE OF TUBES MAGNETIC S BALLASTS Wall Mounted 1'x4' Fixture w/ 2 blubs 19 38 19 and 1 PCB magnetic ballast Mounted 6"x4' Fixture w/ 2 bulbs and 1 161 322 161 PCB magnetic ballast Hanging 2'x4' Fixture w/ 6 bulbs and 2 15 90 30 PCB magnetic ballast Hanging/Mounted Circle shaped fixture 6 6 0 w/ 1 bulb Block A Total 291 810 332 Block B Recessed 4'x4' Fixture w/ 6 bulbs and 2 30 180 60 PCB magnetic ballasts Recessed 2'x4' Fixture w/ 3 bulbs and 2 53 159 106 PCB magnetic ballasts 6"x4" Mounted, grill cover fixture w/ 2 1 2 1 bulbs and 1 PCB magnetic ballast l'x4' Mounted fixture w/ 2 bulbs and 1 2 4 2 PCB magnetic ballast 6"x4' Mounted, snap cover fixture w/ 2 12 24 12 bulbs and 1 PCB magnetic ballast 1'x4' Mounted, swing cover fixture w/ 2 6 12 6 bulbs and 1 PCB magnetic ballast Block B Total 104 381 187 Block C 2'x4' Recessed Fixture w/ 3 bulbs and 2 292 876 584 Magnetic, PCB ballasts 1'x4' Wall/Ceiling mounted fixture w/ 2 16 32 16 bulbs and 1 Magnetic PCB ballast 1'x4' Mounted Fixture w/ 2 bulbs and 1 14 28 14 Magnetic PCB ballast 6"x4" Mounted, grill cover fixture w/ 2 19 38 19 bulbs and 1 PCB magnetic ballast Block C Totals 341 974 633 Block D 2'x4' Recessed Fixture w/ 4 bulbs and 2 145 580 290 Magnetic, PCB ballasts 6"x4" Mounted, grill cover fixture w/ 2 9 18 9 bulbs and 1 PCB magnetic ballast l'x4' Mounted, swing cover fixture w/ 2 24 48 24 bulbs and 1 PCB magnetic ballast ehsi ENS-International,Inc. 15 • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 6 SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS FEDERAL WAY HIGH SCHOOL NUMBER APPROXIMATE LIGHT TYPE OF NUMBER NUMBER OF FIXTURE OF TUBES MAGNETIC S BALLASTS 1'x4' Mounted Fixture w/ 2 bulbs and 1 16 32 16 Magnetic PCB ballast 4'x4' Mounted Fixture w/8 bulbs and 2 55 440 110 Magnetic PCB ballast Block D Totals 249 1,118 449 Block E 2'x4' Recessed Fixture w/ 3 bulbs and 2 78 234 156 Magnetic, PCB ballasts 1'x4' Wall/Ceiling mounted fixture w/ 2 3 6 3 bulbs and 1 Magnetic PCB ballast 6"x4" Mounted, grill cover fixture w/ 2 9 18 9 bulbs and 1 PCB magnetic ballast Block E Totals 90 258 168 Block F 2'x4' Recessed Fixture w/ 4 bulbs and 2 213 852 426 Magnetic, PCB ballasts l'x4' Wall/Ceiling mounted fixture w/ 2 1 2 1 bulbs and 1 Magnetic PCB ballast 1'x4' Mounted Fixture w/ 2 bulbs and 1 11 22 11 Magnetic PCB ballast 6"x4" Mounted, grill cover fixture w/ 2 6 12 12 bulbs and 1 PCB magnetic ballast Block F Totals 231 888 450 Block G 2'x4' Recessed Fixture w/ 4 bulbs and 2 85 340 170 Magnetic, PCB ballasts 1'x4' Wall/Ceiling mounted fixture w/ 2 10 20 10 bulbs and 1 Magnetic PCB ballast 1'x4' Mounted Fixture w/ 2 bulbs and 1 6 12 6 Magnetic PCB ballast 6"x4" Mounted, grill cover fixture w/ 2 3 6 3 bulbs and 1 PCB magnetic ballast Block G Totals 115 400 200 Block H 2'x4' Recessed Fixture w/ 4 bulbs and 2 62 248 124 Magnetic, PCB ballasts 1'x4' Wall/Ceiling mounted fixture w/ 2 11 22 11 bulbs and 1 Magnetic PCB ballast l'x4' Mounted Fixture w/ 2 bulbs and 1 6 12 6 Magnetic PCB ballast 6"x4" Mounted, grill cover fixture w/ 2 1 2 1 bulbs and 1 PCB magnetic ballast ehsi EHS-International,Inc. 15 • • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 6 SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS FEDERAL WAY HIGH SCHOOL NUMBER APPROXIMATE LIGHT TYPE OF NUMBER NUMBER OF FIXTURE OF TUBES MAGNETIC S BALLASTS Block H Totals 80 284 142 Block 7 2'x4' Recessed Fixture w/ 4 bulbs and 2 105 420 210 Magnetic, PCB ballasts 1'x4' Wall/Ceiling mounted fixture w/ 2 10 20 10 bulbs and 1 Magnetic PCB ballast l'x4' Mounted Fixture w/ 2 bulbs and 1 8 16 8 Magnetic PCB ballast 6"x4" Mounted, grill cover fixture w/ 2 4 8 4 bulbs and 1 PCB magnetic ballast Block ] Totals 127 464 232 Block K 2'x4' Recessed Fixture w/ 4 bulbs and 2 103 412 206 Magnetic, PCB ballasts l'x4' Mounted Fixture w/ 2 bulbs and 1 2 4 2 Magnetic PCB ballast Block K Totals 105 416 208 Block L 2'x4' Recessed Fixture w/ 4 bulbs and 2 256 Magnetic, PCB ballasts 64 128 2'x4' Suspended Fixture w/ 4 bulbs and 24 96 48 2 Magnetic, PCB ballast l'x8' Mounted Fixture w/ 2 bulbs and 1 18 36 18 Magnetic, PCB Ballast l'x4' Mounted, swing cover fixture w/ 3 3 9 6 bulbs and 2 Magnetic PCB ballast 6"x4" Mounted, grill cover fixture w/ 2 3 6 3 bulbs and 1 PCB magnetic ballast 6"x4' Suspended Fixture w/ 2 bulbs and 91 182 92 1 Magnetic PCB ballast Block L Totals 203 585 295 Block M 2'x4' Recessed Fixture w/ 4 bulbs and 2 176 704 352 Magnetic, PCB ballasts l'x8' Mounted Fixture w/ 2 bulbs and 1 25 50 25 Magnetic, PCB Ballast 1'x4' Mounted, swing cover fixture w/ 3 49 147 98 bulbs and 2 Magnetic PCB ballast 6"x4" Mounted, grill cover fixture w/ 2 12 24 12 bulbs and 1 PCB magnetic ballast ehSial.. 15 EHS-International,Inc. Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 TABLE 6 SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS FEDERAL WAY HIGH SCHOOL NUMBER APPROXIMATE LIGHT TYPE OF NUMBER NUMBER OF FIXTURE OF TUBES MAGNETIC S BALLASTS 1'x4' Wall/Ceiling mounted fixture w/ 2 5 10 5 bulbs and 1 Magnetic PCB ballast Block M Totals 267 935 492 Covered Walkways 1'x4' Mounted Fixture w/ 2 bulbs and 1 9 18 9 magnetic ballast Covered Walkway Total 9 18 9 P1 6"x4' Mounted, fixture w/ 2 bulbs and 2 14 42 28 Magnetic PCB ballast P1 Totals 14 42 28 P2 2''x4' Recessed Fixture w/ 4 bulbs and 2 48 192 96 Magnetic, PCB ballasts P2 Totals 48 192 96 Community Pool l'x4' Mounted, swing cover fixture w/ 2 35 70 35 bulbs and 1 Magnetic PCB ballast 1'x4' Mounted, swing cover fixture w/ 4 1 2 2 bulbs and 2 Magnetic PCB ballast 1 Circular Fixture w/ 1 bulb and 1 PCB 20 20 20 Magnetic ballast Square recessed fixture w/ 1 round bulb 8 8 8 HID floodlight 1 1 1 Community Pool Totals 65 101 66 3.0 LIMITATIONS This survey was limited to those materials accessible using standard survey methods. Limited representative destructive inspection was accomplished; however, in areas inaccessible for inspection, (e.g., fire door cores) suspect materials were assumed to be ACM. This survey was limited to the chemicals and materials identified herein. No effort was made to identify hazardous materials in soil, water, or air, other than those listed herein. Any survey regardless of how extensive can miss concealed materials. Contractors should be aware of the potential that demolition activities may expose concealed suspect ACM and should have preplanned contingencies for handling these materials when discovered during eh•Si.) 15 ENS-International,Inc. • Limited Hazardous Materials Survey Report Federal Way High School EHSI Project 10527 July 12, 2013 demolition work. Any concealed, suspect ACM material that was not sampled or that was assumed to be ACM by this survey report when encountered must be treated as ACM until sampled by a Certified AHERA Building Inspector and analyzed by a certified laboratory. 4.o STANDARD OF CARE The recommendations and conclusions contained in this report represent the professional opinions of EHSI. These opinions are derived in accordance with federal, state, and local environmental and health and safety laws and regulations. This survey was accomplished in accordance with applicable federal, state, and local regulations and industry standards in effect at the time. Other than this, no other warranty is implied or intended. 5.o CERTIFIED AHERA BUILDING INSPECTORS The Certified AHERA Building Inspectors listed below surveyed Federal Way High School on April 1St-19th and June 25th, 2013, in accordance with federal, state, and local requirements. Brett Racine Rory Peterson Certified AHERA Building Inspector Certified AHERA Building Inspector Certificate Number: 10484-02-03 Certificate Number 10484-02-02 Expiration Date: January 03, 2014 Expiration Date: January 03, 2014 Nadir Khan Lisa Kollasch Certified AHERA Building Inspector Certified AHERA Building Inspector Certificate Number: 10484-02-04 Certificate Number 10484-02-09 Expiration Date: January 03, 2014 Expiration Date: January 03, 2014 ehsi15 • APPENDIX A Asbestos Analytical Laboratory Report and Field Data Forms ehsiJ EHS-International,Inc. Appendix A III • SEAT'' E ASBESTOS TEST Lynnwood Laboratory 19701 Salyer Lake Road,Sule 103, Be9e.ue Laboratory 12727 Northup Way,Sate 1,Bellevue. Seattle Labcescmy 4503 9th Ave_`tE.yule 306.Searle.WA 98105 Lynnwood.WA 98036,Td:425.673.9850.Far 425.673.9810 WA 98098,Tel'425.861_1111,Fax:425.861.1118 Tel:206.6311111,F .206.633.4747 ANALYTICAL LABORATORY REPORT PIM by Method EPA/600/R-931116 Arm.: Mr.Herb Brod calm EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job/: 10527-01r Bee* 201310460 Dace Received. 4/3/2013 Samples Recd 110 Dela Analysed: 4/9/2013 Samples Mal zee 110 PralectLoc. Federal Way High School-Block CCt A Analyzed by: Liz Dutoniklary Srdnrans ReNewed by Steve(Farryaoi/hang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fiixous Components % Non-asbestos Fibers 1 Beige/gray rubbery None Rubber/binder 2 Cellulose material detected one 1 10527-A-01 2 Tan mastic ae tected Mastic/binder 3 Cellulose None 3 White/beige paintetedPaint/binder 2 Cellulose dect 1 Gray soft/elastic None Binder, Filler, Paint 4 Cellulose 2 10527-A-02 material with paint detected 2 Yellow foamy None Synthetic foam None detected material detected 1 White brittle None Binder/filler, Paint, 5 Cellulose 3 10527-A-03 material with paint detected Sands 2 White chalky None Binder/filler, Cellulose, material with paper detected Gypsum/binder 26 Glass Fibers 1 White brittle None Binder/filler, Paint, 6 Cellulose 4 10527-A-04 material with paint detected Sands 2 White chalky None Binder/filler, Cellulose, material with paper detected Gypsum/binder 24 Glass Fibers 1 White brittle None Binder/filler, Paint, 7 Cellulose 5 10527-A-05 material with paint detected Sands 2 White chalky None Binder/filler, Cellulose, material with paper detected Gypsum/binder 25 Glass Fibers 1 Gray fibrous None Paint, Filler, Glass Glass fibers, 6 10527-A-06 material with paint detected beads 66 Cellulose None 2 Brown mastic Mastic/binder 5 Cellulose, White powdery 1 material with None Binder/filler 27 Cellulose, 7 10527-A-07 woven fibrous detected Glass fibers material 2 White chalky None Binder/filler, 23 Cellulose, material with paper detected Gypsum/binder Glass Fibers 8 10527-A-08 1 Tan soft material None Filler, Binder 5 Cellulose, detected Wollastonite 1 Off-white tile None Vinyl/binder, 3 Cellulose detected Mineral grains 9 10527-A-09 2 Yellow mastic deed Mastic/binder 4 Cellulose Gray None 3 mater alttie d Filler, Binder 2 Cellulose 1 White brittle None Binder/filler, Paint, 5 Cellulose 10 10527-A-10 material with paint detected Sands 2 White chalky None Binder/filler, Cellulose.. material with paper detected Gypsum/binder 29 Glass Fibers 1 White brittle None Binder/filler, Paint, 5 Cellulose 11 10527-A-11 material with paint detected Sands 2 White chalky None Binder/filler, 29 Cellulose. material with paper detected Gypsum/binder Glass Fibers 12 10527-A-12 1 White brittle None Binder/filler, Paint, 5 Cellulose material with paint detected Sands 1 • • SEATTLE ASBESTOS TEST NVLAP Accreditation Lab e-276,Lynnwood-20e Lynnwood Laboratory 19701 Scriber Lake Road,Suite 103, Bellevue Laboratory 12727 Nortlup Way,Suite 1,Belevue, Seattle Laboratory 4500 9th Ave NE,State 300.Seattle,WA 96105 • Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tet 425.861.1111,Fax 425.861.1118 Tel:206.633.1111,Fax 206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Ami.: Mr.Herb Brod csent EHS International,Inc. mere= 13228 NE 20th St#100,Bellevue.WA 98005 ,lob#: 10527-01r Batdgr: 201310460 Data Received: 413/2013 samples Recd: 110 Date Analyzed: 4/9/2013 SamWee Analyzed: 110 Federal Way High School-Block r��� Project Loc.: A Analyzed by: Liz Dutton/Mary Eiomann Renewed by: Steve(Fanyaol Zhang.President Lab ID Client Sample ID Layer Description % Asbestos Febers Non-fibrous Components % Non-asbestos Fibers White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 29 Glass Fibers 1 Black rubbery None Rubber/binder 2 Cellulose material detected 13 10527-A-13 2 Cream mastic Ndetected Mastic/binder 3 Cellulose Non3 White paintPaint/binderPaint/binder 2 Cellulose 1 Blue woven fibrous None Filler, Binder 85 Synthetic fibers material detected Gray None 14 10527-A-14 2 material foamy detected Synthetic foam None detected e • 3 Yellow mastic Betted Mastic/binder 3 Cellulose White soft material None Filler, Binder, Foil, 1 with silver foil and detected Mastic/binder 2 Cellulose 15 10527-A-15 mastic Gray fibrous None Cellulose, 2 material detected Filler, Glass beads 69 Glass fibers 1 Orange/brown None Ceramic/binder None detected ceramic detected 16 10527-A-16 2 Gray sandy/brittle None Binder, Sand 2 Cellulose material detected _ 3 Gray brittle/sandy None Filler, Binder 2 Cellulose material detected 1 Orange/brown None Ceramic/binder None detected ceramic detected _ 2 Gray sandy/brittle None Binder, Sand 2 Cellulose 17 10527-A-17 material detected Black/dark gray 3 brittle/sandy d onetected Filler, Binder 3 Cellulose material Black soft material None Filler, 18 10527-A-18 1 with white paint detected Asphalt/Binder, 5 Cellulose Paint 1 Beige paint None Paint 2 Cellulose detected 19 10527-A-19 2 White brittle None Filler, Binder 4 Cellulose material detected 3 Gray sandy brittle None Sand, Filler, Binder 6 Cellulose material detected 1 Beige paint None Paint 3 Cellulose 20 10527-A-20 2 White brittle None Filler, Binder 3 Cellulose material detected 3 Gray sandy/brittle None Sand, Filler, Binder 5 Cellulose material detected Non21 10527-A-21 1 White paint dected Paint/binder 2 Cellulose 2 • • SEATTLE ASBESTOS TEST ` /LAP Accreditation Lab codes: . 78, Lynnwood Laboratory:19701 Sather Lake Road,Stile 103, Beleme Laboratory 12727 Nor8 Way.Suite 1.Bellevue, Searle Laboratory:4500 9er Ave.NE.Sage 3W.Seattle,WA 98105. • Lynnwood,WA 98036.Tel 425.673.9850.Fax 425.6718010 WA 98005,Tel:425.861.1111.Fax 425 861.1118 Tet 208.633.1111.Fax 208.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA16001R-931116 + = Mr.Herb Brod tier( ENS International,Inc. Adrift= 13228 NE 20th St#100,Bellevue,WA 98005 Jot: 10527-01r Balm({: 201310460 Date Received: 4/3/2013 samples Redd: 110 Date/wisheee 419/2013 Saevies• 110 Project Loc: Federal Way High School-Block Analyzed by. Liz GmcnlMary Eidmann Reviewed bF Save iFatyaoy Zhang,Presdent Lab ID Client Sample ID Layer Description % Asbestos Fliers Non-fdxous Components % Non-asbestos Fibers None 2 Silver paint Paint/binder 2 Cellulose 3 Gray sandy/brittle None Sand, Filler, Binder 3 Cellulose material detected 1 White paint Nd one Paint/binder 2 Cellulose 22 10527-A-22 2 Silver paint detected Paint/binder 4 Cellulose 3 Gray sandy/brittle None Sand, Filler, Binder 3 Cellulose material detected 1 Beige paint Node PaintPaint 3 Cellulose 23 10527-A-23 2 White brittle None Filler, Binder 3 Cellulose material detected 3 Gray sandy/brittle None Sand, Filler, Binder 5 Cellulose material detected 1 White paint de Paint/binder 2 Cellulose ted Non 24 10527-A-24 2 Silver paint detected 4 Cellulose Gray sandy/brittle None 3 material detected Sand, Filler, Binder 3 Cellulose Non 1 Beige paint dtected Paint 3 Cellulose 25 10527-A-25 2 White brittle None Filler, Binder 2 Cellulose material detected 3 Gray sandy/brittle None Sand, Filler, Binder 5 Cellulose material detected 1 Beige paint deter Paint 2 Cellulose 26 10527-A-26 2 White brittle None Filler, Binder 2 Cellulose material detected 3 Gray sandy/brittle None Sand, Filler, Binder 3 Cellulose material detected Black asphaltic Filler,Asphalt, 1 material with 20 Chrysotile Binder 30 Cellulose fibrous material Multi-layered black Filler,Asphalt, 2 asphaltic fibrous 21 Chrysotile Binder 27 Cellulose 27 10527-A-27 material 3 Brown fibrous None Filler 90 Cellulose material detected Black asphaltic Filler,Asphalt, 4 material with 21 Chrysotile Binder 29 Cellulose fibrous material Black asphaltic Filler,Asphalt, 1 material with 20 Chrysotile Binder 30 Cellulose 28 10527-A-28 fibrous material 2 Black asphaltic None Asphalt/binder, 2 Cellulose material detected Filler 3 • • o SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Co Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory 12727 Narthup Way,Stale 1,Bellevue, Seattle Laboratory 4500 9th Ave NE.State 300.Seatte.WA 98105 • Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel 425.861.1111,Fax 425.861.1118 Tat:206.633.1111,Fax.205.633.474 7 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Attn.: Mr.Herb Brod Gent EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job#: 10527-01r Batde: 201310460 nate Received: 413/2013 Samples Redd: 110 Date Analyte 4/9/2013 samples Analyzed: 110 Loc.: Federal Way High School-Block PrclectA Analyzed by taz DunoNAtary Eidmarn Reviewed by: Steve(Fanyaol 2harg.President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 3 Black asphaltic 23 Chrysotile Filler,Asphalt, 30 Cellulose fibrous material Binder 4 Black asphaltic 20 Chrysotile Filler,Asphalt, 28 Cellulose fibrous material Binder 5 Black asphaltic 22 Chrysolite Filler,Asphalt, 31 Cellulose fibrous material Binder 6 Black asphaltic 22 Chrysotile Filler,Asphalt, 29 Cellulose fibrous material Binder 7 Black asphaltic 21 Chrysotile Filler,Asphalt, 23 Cellulose fibrous material Binder 8 Brown fibrous None Filler 90 Cellulose material detected Black asphaltic Filler,Asphalt, 9 material with 20 Chrysotile Binder 29 Cellulose fibrous material 29 10527-A 29 1 Gray cementitious None Cement/binder, 2 Cellulose material detected Sands 1 White ceramic detested Ceramic/binder None detected 30 10527-A-30 2 White brittle None Binder 2 Cellulose material detected 3 Tan mastic with None Mastic/binder, 4 Cellulose paint detected Paint Non 1 Gray ceramic dected Ceramic/binder None detected Dark 2 gray brittle/sandy doetnected Binder, Sand 3 Cellulose material Dark e 31 10527-A-31 3 gray sandy/brittle date a Binder, Sand 3 Cellulose material 4 Yellow mastic None Masticlbinder, 4 Cellulose detected Paint Trace gray None 5 cementitious Cement/binder 2 Cellulose detected material White brittle No1 material with trace ste eed Binder/filler, Paint 5 Cellulose de32 10527-A-32 paint 2 White chalky None Binder/filler, 25 Cellulose, material with paper detected Gypsum/binder Glass fibers White brittle None 1 Binder/filler, Paint 4 Cellulose 33 10527-A-33 material with paint detected 2 White chalky None Binderlfiller, 26 Cellulose. material with paper detected Gypsum/binder Glass fibers 1 White brittle None Binder/filler, Paint 5 Cellulose 34 10527-A-34 material with paint detected 2 White chalky None Binder/filler, 25 Cellulose. material with paper detected Gypsum/binder Glass fibers 4 • s SEATTLE ASBESTOS TEST Lynnwood Laboratory:19701 Som Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way.Suite 1,Bellevue, Seattle Laboratory'4500 9th Ave.NE.Suite 300,Seattle,WA 98105. Lynnwood,WA 98036,TeL 425.673.9850.Fax:425.673.9810 WA 98005,Tel:425.861.1111.Fax:425.861.1118 Tel.206.633.1111,Fax 206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Amt.: Mr.Herb Brod Client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Jowl: 10527-01r Batddt: 201310460 Date Received: 4/3/2013 Samples Recd 110 Date Aneyzed: 4/9/2013 Samples . 110 Federal Way High School-Block Projed Loc.: A Analyzed by: Liz Dutton/Mary Eidmann Reviewed by: Steve(Fanyaol Zhang,President Lab ID Chant Sample ID Layer Description % Asbestos Fibers Non-fibrous Components ',o Non-asbestos Fibers White brittle None 1 Binder/filler, Paint 3 Cellulose 35 10527-A-35 material with paint detected White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 23 Glass fibers White brittle None 1 Binder/filler, Paint 3 Cellulose 36 10527-A-36 material with paint detected White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 27 Glass fibers Paint, Filler, Gray fibrous None Cellulose, 37 10527-A-37 1 Pmaterial with paint detected erlite, Glass 66 Glass fibers b beads 38 10527-A-38 1 White soft/elastic None Binder, Filler None detected material detected 1 Beige woven None Filler, Binder 85 Synthetic fibers fibrous material detected 39 10527-A-39 2 Yellow mastic d tet�ed Masticbinder 3 Cellulose 3 Tan/gray mastic None Mastic/binder 4 Cellulose detected 40 10527-A-40 1 White soft material None Binder, Filler, Paint 2 Cellulose with paint detected Gray/brown/yellow/ None Vinyl/binder, 1 white tile detected Mineral grains 2 Cellulose 41 10527-A-41 None 2 Black mastic detected Mastic/binder 6 Cellulose 1 Yellow mastic None Mastic/binder 2 Cellulose detected 42 10527-A-42 2 Gray brittle None Filler, Binder 2 Cellulose material detected 3 Black mastic None Mastic/binder 5 Cellulose detected 1 Yellow mastic NonetMastic/binder 2 Cellulose 43 10527-A-43 2 White brittle None Filler, Binder 2 Cellulose material detected 3 Black mastic None Mastic/binder 5 Cellulose 1 Red ceramic dcted etee cted Ceramic/binder None detected 44 10527-A-44 2 Gray brittle/sandy None Binder, Sand 2 Cellulose material detected 3 Gray sandy/brittle None Binder, Sand 3 Cellulose material detected 45 10527-A-45 1 Black asphaltic None Asphalt/binder 4 Cellulose material detected 1 White paint None Paint/binder 2 Cellulose 46 10527-A-46 detected 2 Tan fibrous None Paint, Filler, Binder 65 Cellulose material detected 5 • • . SEATTLE ASBESTOS TES,.. Lynnwood Laboratory 19701 Scriber Lake Road,Suite 103 Bellevue Labordaey 12727 North*Way,Sure 1,Beiente, Seattle Laboratory 4500 Stir Ave.NE Siete 300 Searle,WA 98135 Lynnwood,WA 98036,Tel:425.673.9850.Fax:425 6730810 WA 98005,Tui:425.861.1 t 11,Far 425.861.1118 Tel 206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R 93/116 Mn.: Mr.Herb Brod orient ENS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job* 10527-01r mishit 201310460 Dere Received: 4/3/2013 Samples Rodd: 110 Date Aridyzadd 4/9/2013 Samples Analyzed: 110 Project Loc.: Federal Way High School-Block 4-- A Analyzed by (az Dolton/Mary Eidmann Reviewed by Steve(Fanyao)2bang..Presdent Lab ID Client Sample ID Layer Description % Asbestos Filers Non-fibrous Components % Non-asbestos Fibers 3 White/brown None Filler, Binder 79 Cellulose fibrous material detected 4 Brown mastic Nonel Mastic/binder 3 Cellulose, 1 cted Brown rubbery 2 Chrysotile Rubber/binder 2 Cellulose material 47 10527-A-47 one 2 Green mastic d Mastic/binder 5 Cellulose etected Brown/yellow on3 mastic with deteected Mastic/binder 7 Cellulose powdery material 1 Brown vinyl 2 Chrysotile Vinyl/binder 3 Cellulose 48 10527-A-48 2 Yellow mastic None Mastic/binder 6 Cellulose detected 1 Brown vinyl 2 Chrysotile Vinyl/binder 2 Cellulose 49 10527-A-492 Brown mastic None detected Mastic/binder 5 Cellulose 1 Brown rubbery None Rubber/binder 3 Cellulose material detected 50 10527-A-50 2 Cream mastic Ndete ed Mastic/binder 5 Cellulose 3 Tan/brown mastic deed Mastic/binder 6 Cellulose 1 Beige rubbery None Rubber/binder 3 Cellulose 51 10527-A-51 material detected 2 Cream mastic detected Mastic/binder 4 Cellulose 1 Dark None Mastic/binder 4 Cellulose 52 10527-A-52 brown/gray mastic detected 2 Tan wood debris detected Wood debris 7 Cellulose 1 White brittle None Binder/filler, Paint, 5 Cellulose 53 10527-A-53 material with paint detected Sands 2 White chalky None Binder/filler, Cellulose, material with paper detected Gypsum/binder 29 Glass Fibers 1 White brittle None Binder/filler, Paint, 3 Cellulose 54 10527-A-54 material with paint detected Sands 2 White chalky None Binder/filler, 31 Cellulose, material with paper detected Gypsum/binder Glass Fibers 1 White brittle None Binder/filler, Paint, 4 Cellulose 55 10527-A-55 material with paint detected Sands 2 White chalky None Binder/filler, 25 Cellulose, material with paper detected Gypsum/binder Glass Fibers 1 White brittle None Binder/filler. Paint, 3 Cellulose 56 10527-A-56 material with paint detected Sands 2 White chalky None Binder/filler, 23 Cellulose. material with paper detected Gypsum/binder Glass Fibers 57 10527-A-57 1 White brittle None Binder/filler, Paint, 2 Cellulose material with paint detected Sands 6 • SEATTLE ASBESTOS TEST Lyrviwood Laboratory.19701 Saber take Road,Site 103, Bellevue Laboratory:12727 trodbup Way.Sate 1,revue. Seattle Laboratory 4520 9a1 Ave.NE,Stile 300,Seat le,WA 98105, • Lynnwood,WA 98036,Tel:425.673.9850.Far 425.673.9810 WA 98005,Tet 425.861.1111,Fax 425.861 1118 -el:205.633.1111,Far 206.933.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPAf600/R-93/116 Attn.: Mr.Herb Brod (=tent EHS International,Inc. Addresr 13228 NE 20th St#100,Bellevue.WA 98005 Jobe 10527-01r Biu: 201310460 Date Received: 4/3/2013 samples Read: 110 Dees Me.Yyzad: 4/9/2013 samples Analyzed: 110 Loc-:. Federal Way High School-BlockProject — A -0121110 Analyzed by: Liz Otrec tklary Eidrnarn Reviewed by: Steve{Fa:yaoi Znany,.Presnent Lab ID Client Sample ID Layer Description % Asbestus Fibers Non-fibrous Components % Non-asbestos Fibers White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 29 Glass Fibers Black soft/elastic 58 10527-A-58 1 material with None Filler, Binder, Paint 30 Glass fibers woven fibrous detected material and paint 59 10527-A-59 1 Tan soft material None Filler, Binder 6 Cellulose, detected Wollastonite Tan fibrous None 1 material with white detected Filler, Paint 90 Cellulose 60 10527-A-60 paint No2 Brown mastic ntected Mastic/binder 3 Cellulose, deYellow mastic with 61 10527-A-61 1 white brittle None Mastic/binder 2 Cellulose material and wood detected debris White brittle 1 material with paint None Binder/filler, Paint, 13 Cellulose, 62 10527-A-62 and woven fibrous detected Sands Glass Fibers material White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 23 Glass Fibers 1 White brittle None Binder/filler, Paint, 4 Cellulose 63 10527-A-63 material with paint detected Sands White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 25 Glass Fibers 1 White powdery 2 Chrysotile Binder/filler 2 Cellulose 64 10527-A-64 material 2 Pink chalky None Binder/filler, 25 Cellulose material with paper detected Gypsum/binder 1 White powdery 2 Chrysotile Binder/filler, Paint 4 Cellulose 65 10527-A-65material with paint 2 Pink chalky None Binder/filler, 26 Cellulose material with paper detected Gypsum/binder White brittle 1 material with paint None Binder/filler; Paint, 3 Cellulose 66 10527-A-66 and powdery detected Sands material White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 25 Glass Fibers White brittle None Binder/filler, Paint, 1 5 Cellulose 67 10527A-67 material with paint detected Sands White chalky None Binder/filler, Cellulose. 2 material with paper detected Gypsum/binder 23 Glass Fibers 1 White brittle None Binder/filler, Sands 5 Cellulose 68 10527-A-68material detected 2 White chalky None Binder/filler, 24 Cellulose, material with paper detected Gypsum/binder Glass Fibers 7 • . NVLAP&meditation Lab Codes: 200878,L 20t Lynnwood Laboratory-19701 Saioer Lake Road,Suite 103, Bellevue Laboratory:11x1!Ncethp Way,Sine 1.Bim, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, Lynnwood,WA 98036,Tel.425.673.9850,Far:425.673,9810 WA 98005,Te!'425.881.1111,Faxc 425.861.1118 Tel-208.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/I300/R-93/116 AIM.: Mr.Herb Brod Client EHS International,Inc. Address 13228 NE 20th St#100.Bellevue,WA 98005 Job#: 10527-01r Bal: 201310460 Data Received: 4/3/2013 samples Reed: 110 Date Analyzed: 4/9/2013 samples Arrehrmd: 110 Project Loc.: Federal Way High School-Block ` A t Analyzed by Liz Duttor:A4ary Eidman Reviewed by Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers None 1 White paint Paint/binder 2 Cellulose detected 69 10527-A-69 Gray sandy/brittle None 2 material detected Sand, Filler, Binder 3 Cellulose None 1 White paint Paint/binder 2 Cellulose detected 70 10527-A-70 Gray sandy/brittle None 2 material detected Sand, Filler, Binder 4 Cellulose None 1 Gray paint Paint/binder 2 Cellulose detected 71 10527-A-71 2 Gray sandy/brittle None Sand, Filler, Binder 2 Cellulose material detected 1 Brown ceramic None Ceramic/binder None detected detected 2 Gray brittle/sandy None Binder, Sand 2 Cellulose 72 10527-A-72 material detected 3 Beige mastic d°neteected Mastic/binder 2 Cellulose 4 Gray brittle/sandy None Binder, Sand 2 Cellulose material detected 73 10527-A-73 1 Gray soft/elastic Norte Binder, Filler 4 Cellulose material detected Black foamy None Synthetic foam, 74 10527-A-74 1 material with paint detected Paint, 2 Cellulose and mastic Mastic/binder 1 White soft/elastic None Binder, Filler, Paint 4 Cellulose material with paint detected 75 10527-A-75 Trace gray 2 sandy/brittle detected Sand, Filler, Binder 3 Cellulose material Black mastic with None Mastic/binder, 76 10527-A-76 1 debris detected Debris, Fine 5 Cellulose particles 1 White ceramic None Ceramic/binder None detected detected 77 10527-A-77 2 White None Binder 2 Cellulose brittle material detected 3 Tan mastic None Mastic/binder 3 Cellulose detected one 1 Gray ceramic d Ceramic/binder None detected 2 etected Gray brittle/sandy None Binder, Sands 4 Cellulose material detected 3 Yellow mastic None Mastic/binder 3 Cellulose 78 10527-A-78 detected Dark gray 4 brittle/sandy de�teeted Binder, Sands 4 Cellulose material 5 Gray cementitious None Cement/binder, material detected Sands 2 Cellulose 8 411 1111 , SEATTLE ASBESTOS TEST Lynnwood Laboratory:19701 Scriber lake Road,Sale 103, Belem,Laboratory 12727 Narep Way.Sine 1,8eleave, Seattle Laboratory.4500 341 Ave.NE Bute 2,93 Seattle,.1'4 931;5.. Lynnwood.WA 98336,Tel:425.6739450,Fax:425.573.9610 WA 961106,Tet:425.361 1111,Fax 425.861.1118 Tel 266.633.1111.Far 236.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-931116 Atm.: Mr.Herb Brod am* EHS International,Inc_ Address: 13228 NE 20th St#100,Bellevue,WA 98005 .low: 10527-01r Bad: 201310460 Date Received: 4132013 Samples Reed: 110 oats Analyzed: 4192013 Samples Analyzed: 110 Federal Way High School-Block Protect LOG: A Analyzed by: Liz Duttonlaary ESS ane Reviewed by: Steve IFanyaoi 2tag.Preslden•. Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 79 10527-A-79 1 Beige soft/elastic None Binder, Filler 2 Cellulose material detected 80 10527-A-80 1 Beige soft/elastic None Binder, Filler 3 Cellulose material detected None 81 10527-A-81 1 Gray soft material Filler, Binder 5 Cellulose detected Yellow/tan soft 'None Cellulose, 82 10527-A-82 1 material detected Filler, Binder 3 Wollastonite 1 Black sandy/brittle None Sand. Filler, Binder 3 Cellulose material detected Trace 83 10527-A-83 2 gray sandy/brittle None Sand, Filler; Binder 3 Cellulose etected material None 3 Brown wood debris de ed Wood debris 7 Cellulose Off None Filler, Fine 84 10527-A-84 1 white soft/loose detected particles 5 Cellulose material White brittle None 1 Filler, Binder, Paint 2 Cellulose 85 10527-A-85 material with paint detected 2 Gray sandy/brittle None Sand, Filler, Binder 4 Cellulose material detected White brittle None 1 Filler, Binder; Paint 2 Cellulose 86 10527-A-86 material with paint detected Gray sandy/brittle None 2 material detected Sand,Filler, Binder 3 Cellulose White brittle None 1 material with paint detected Filler, Binder, Paint 3 Cellulose 87 10527-A-87 Gray sandy/brittle None 2 material detectedSand, Filler. Binder 3 Cellulose None Cellulose, 1 Yellow masticdetectedMastic/binder 5 Synthetic fibers 88 10527-A-88 2 Brown tile 3 Chrysotile Vinyl/binder, 2 Cellulose Mineral grains 3 Black mastic detected Mastic/binder 4 Cellulose 1 Yellow mastic None Mastic/binder 6 Cellulose, detected Synthetic fibers Gray e 89 10527-A-89 2 material detected Filler, Binder 3 Cellulose 3 Brown tile 3 Chrysotile Vinyl/binder, 3 Cellulose Mineral grains 4 Black mastic detected Mastic/binder 4 Cellulose 90 10527 A-90 1 Green/dark gray None Filler, Binder 4 Cellulose soft material detected None 91 10527-A-91 1 Gray soft material Filler, Binder 2 Cellulose detected 92 10527-A-92 1 White brittle None Filler, Binder, 3 Cellulose material detected Perlite 9 • • NVLAP Accreditation Lab Codes: 76,Lyr nwwcod-200768 Lynnwood Labo'aiory-19701 So-bar Lake Road.State 103, Bellevue Laboratory:12727 Narthup Wey,Stine 1,eeievae, Seatle Laboratory:45009th Ave.I'E.Suite 300,Seattle,WA 98105, Lynnwood WA 980336.T 425.673.9850,Fax 425.673.9810 WA 9e8005,Tel:425.861.1111,Fax 425.861.1118 Tel 206833,1111,Fax 208.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA1600/R-93/116 Atm.: Mr.Herb Brod (Sent EHS International,Inc. Aeaesc 13228 NE 20th St#100,Bellevue,WA 98005 Jaw 10527-01r Sat 201310460 Date Receive& 4/3/2013 semdes Redd: 110 Date Analyzed: 4/9/2013 samples Maiyzed: 110 Project # i Loc. Federal Way High School-Block A Analyzed by Liz DeffionAtary Eidmam Reviewed by. Steve tFanyaol Zttan9.€rescent Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers White/gray fibrous None Paint, Filler, 1 Perlite, Glass 68 Cellulose. 93 10527-A-93 material detected Glass fibers fibers 2 Brown mastic None Mastic/binder 3 Cellulose detected 1 Light None Vinyl/binder, gray/white/gray tile detected Mineral grains 2 Cellulose 94 10527-A-94 2 Yellow mastic None Mastic/binder 4 Cellulose detected 3 Black mastic None Mastic/binder 5 Cellulose detected 1 Blue tile None Vinyl/binder, detected Mineral grains 2 Cellulose 95 10527-A-95 2 Yellow mastic None Mastic/binder 4 Cellulose detected 3 Black mastic None Mastic/binder 5 Cellulose detected 1 Blue woven fibrous None Filler, Binder 85 Synthetic fibers material detected 2 Yellow mastic None Mastic/binder 3 Cellulose 96 10527-A-96 detected 3 Gray brittle None material detected Filler, Binder 2 Cellulose 4 Black mastic 3 Chrysotile Mastic/binder 3 Cellulose 97 10527-A-97 1 Tan soft material None Filler, Binder 3 Cellulose detected Red rubbery None Rubber/binder, 98 10527-A-98 1 material with soft 4 Cellulose material detected Filler 99 10527-A-99 1 Black soft/elastic None material detected Binder, Filler 2 Cellulose 100 10527-A-100 1 White soft/elastic None material detected Binder, Filler 2 Cellulose Black asphaltic 101 10527-A-101 1 material with None Asphalt/binder, brown woven detected Filler 63 Cellulose fibrous material Black asphaltic 102 10527-A-102 1 material with Nate Asphalt/binder, brown woven detected Filler 26 Cellulose fibrous material 103 10527-A-103 1 White brittle None material detected Filler, Binder 2 Cellulose 1 Brown cork None Cork detected None detected 104 10527-A 104 2 White powdery None material detected Filler, Binder 2 Cellulose 3 Gray cementitious None Cement/binder, material detected Sands None detected 10 • SEATTLE ASBESTOS TEST• Lynnwood laboratory:19701 Scriber Lake Road.Sode 103. aeaewe Laboratory:12727 Nordsp W`ay,Sure 1.Bellevue, Seale Laboratory:4500 981 Ave NE,Suite 300.Seattle.WA 98105. Lymwood,WA 98036,Tel:425.673.9850,Fax 425.673.9810 WA NOM.Tel:425.861_1111.Fax 425.861.1118 T .206.633.1111,Fax 206.633.4747 ANALYTICAL LABORATORY REPORT PCM by Method EPA/60OlR-93/116 Ann: Mr.Herb Brod meet EHS International,Inc. Mike= 13228 NE 20th St#100,Bellevue,WA 98005 .tart 10527-01r Bay 201310460 Dete Realest 4/3/2013 sanplea Redd: 110 Dam Mehr 4/9(2013 srmpies MalYaart 110 Project t . Federal Way High School-Block A Analyzed by L¢Dutton9ary Eidnran Reviewed try Steve(Fanyao)Zhang.Prescient Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers White brittle None Binder/filler, Paint, 1 5 Cellulose 105 10527-A-105 material with paint detected Sands 2 White chalky None Binder/filler, 23 Cellulose, material with paper detected Gypsum/binder Glass Fibers White brittle None Binder/filler, Paint, 1 3 Cellulose 106 10527-A-106 material with paint detected Sands 2 White chalky None Binder/filler, 26 Cellulose, material with paper detected Gypsum/binder Glass Fibers 1 White brittle None Binder/filler, Paint, Cellulose 4 107 10527-A--107 material with paint detected Sands 2 White chalky Norte Binder/filler, 24 Cellulose, material with paper detected Gypsum/binder Glass Fibers 1 Black loose brittle None Filler, Binder 2 Cellulose 108 10527-A-108 material detected Gray sandy/brittle None 2 material detected Sand, Filler, Binder 3 Cellulose 109 10527-A-109 1 Gray soft/elastic None Binder, Filler, Paint 4 Cellulose material with paint detected 110 10527 A-110 1 White soft/elastic None Binder, Filler 2 Cellulose material detected • 11 • S SEA$ ASBESTOS TEST Accri,irlitatIonLab C t s.,?:ell.,v e-2005 Lynnwood-250753 Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory-4500 9th Ave.NE,Suite 300,Seattle,WA 98105, Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel.425.861.1111,Fax:425.861.1118 Tel:206633-1111.Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Attn.: Mr.Herb Brod client EHS International,Inc. Adm: 13228 NE 20th St#100,Bellevue,WA 98005 Job#: 10527-01R Batct 201310610 Date Received: 4/10/2013 Samples Redd: 11 Pate Analyzed: 4/17/2013 Samples Analyzed: 11 Federal Way High School,Block ' /j Project Loc.: A i Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers Pink/white fibrous None Filler, Fine 1 material with trace detected particles, 87 Cellulose 1 10527-A-111 mastic Mastic/binder None 2 Brown wood debris detected Wood debris 6 Cellulose Pink/yellow fibrous None Filler, Fine 2 10527-A-112 1 material with detected particles, 89 Cellulose mastic Mastic/binder Pink/yellow fibrous None Filler, Fine 1 material with particles, 90 Cellulose 3 10527-A-113 mastic detected Mastic/binder None 2 Brown wood debris detected Wood debris 7 Cellulose Pink/yellow fibrous None Filler, Fine 1 material with detected particles, 88 Cellulose 4 10527-A-114 mastic Mastic/binder 2 Brown wood debris None Wood debris 6 Cellulose detected Pink/white fibrous None Filler, Fine 1 material with trace particles, 86 Cellulose mastic detected Mastic/binder 5 10527-A-1152 White powdery None Binder/filler 32 Cellulose material with paper detected 3 White chalky None Binder/filler, Cellulose, material with paper detected Gypsum/binder 37 Glass fibers Pink/white fibrous Filler, Fine 1 material with None particles, 85 Cellulose detected Mastic/binder 6 10527-A-116 mastic 2 White chalky None Binder/filler, Cellulose, material with paper detected Gypsum/binder 38 Glass fibers Pink/white fibrous None Filler, Fine 1 material with particles, 91 Cellulose 7 10527-A-117 mastic detected Mastic/binder 2 White chalky None Binder/filler, 40 Cellulose, material with paper detected Gypsum/binder Glass fibers 1 Brown paper with None Filler, 77 Cellulose asphaltic material detected Asphalt/binder None 2 Brown wood block detected Wood aggregates 5 Cellulose 8 10527-A-118 Black asphaltic fibrous material Filler,Asphalt, 33 Cellulose 3 with asphaltic 21 Chrysotile Binder material None 1 Brown wood block detected Wood aggregates 6 Cellulose 9 10527-A-119 2 Brown paper with None Filler, 79 Cellulose asphaltic material detected Asphalt/binder 3 Brown wood block None Wood aggregates 7 Cellulose detected 1 • • SEATTLE EATE ASBESTOS TEST ?..i.itliP Accreditation Lab�e�ss_Etei ietue-2;£8f3,Ly ri oadh OOr6$ Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory 12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, Lynnwood,WA 98036,Tel:425673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax 425.861.1118 Tel:206.633.1111,Fax 206.533.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPN600/R-93/116 Attn.: Mr.Herb Brod client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 ,lob#: 10527-01R Batch# 201310610 Date Received: 4/10/2013 Samples Redd: 1 1 Date Analyzed: 4(17/2013 Samples Analyzed: 11 ectLoa: Federal Way High School,Block r7 (,;;Z.,' ProjAnalyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers Multi-layered black Filler,Asphalt, 4 asphaltic fibrous 19 Chrysotile Binder, Fine 37 Cellulose material with particles, Debris debris 5 Black asphaltic None Asphalt/binder 3 Cellulose material detected 1 Brown wood block Nonet ed Wood aggregates 7 Cellulose 2 Brown paper with None Filler, 78 Cellulose asphaltic material detected Asphalt/binder 10 10527-A-120 3 Brown wood block ducted Wood aggregates 5 Cellulose Black asphaltic 4 fibrous material 20 Chrysotile Filler,Asphalt, 36 Cellulose with asphaltic Binder material Brown wood None 11 10527-A-121 1 debris with fibrous detected Wood debris, Filler 27 Cellulose material 2 • • SEATTLE ASBESTOS TEST NVLAP Accreditation Lan Codes.200768 and 200876 19711 Scriber Lake Road,Suite 0,Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 12727 Northup Way.Suite 1,Bellevue,WA 98005,Tel:425.861.1111,Fax:425.861.1118 Website:vnvw.seatlieasbestostesLcom,Email:admin(r seatfeasbestostestcom PLM by Point Count(400 Points) Client Job#: 10527-01r Attention: Mr.Herb Brod Laboratory Batch#: 201310867 Client: EHS international,Inc_ Date Received: 4/22/2013 Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 2 Date Analyzed: 4/25/2013 Project: Federal Way High School-Block A Sample Requested for Point Count 10527-A-64 Previous Analytical Information Previously Analyzed by: Liz Dutton Previous Batch#: 201310460 Previous Lab ID: 64 Previous Description: White powdery material Layer to be Point Counted: 1 Asbestos Type Found: Chrysotile Asbestos Percentage Found: 2 Point Count Analytical Procedures New Lab ID: 1 Asbestos Points Non-Asbestos Points Total Points Counted Slide 1 0 50 50 Slide 2 0 50 50 Slide 3 0 50 50 Slide 4 1 49 50 Slide 5 1 49 50 Slide 6 0 50 50 Slide 7 0 50 50 Slide 8 0 50 50 Total 2 398 400 Point Count Summary Results Type of Asbestos: Chrysotile Percentage of Asbestos: 0.5% Analyzed By: Liz Dutton Reviewed by: Steve(Fanyao)Zhang, President 1 • • SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Codes:200768 and 200876 19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 12727 Northup Way,Suite 1,Bellevue,WA 98005,Te1:425.861.1111,Fax:425.861.1118 Website:www.seattleasbestostest.com,Email:admin@seattleasbestostest.com PLM by Point Count(400 Points) Client Job#: 10527-01r Attention: Mr.Herb Brod Laboratory Batch#: 201310867 Client: EHS International,Inc. Date Received: 4/22/2013 Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 2 Date Analyzed: 4/25/2013 Project: Federal Way High School-Block A Sample Requested for Point Count 10527-A-65 Previous Analytical Information Previously Analyzed by: Liz Dutton Previous Batch#: 201310460 Previous Lab ID: 65 Previous Description: White powdery material with paint Layer to be Point Counted: 1 Asbestos Type Found: Chrysotile Asbestos Percentage Found: 2 Point Count Analytical Procedures New Lab ID: 2 Asbestos Points Non-Asbestos Points Total Points Counted Slide 1 1 49 50 Slide 2 0 50 50 Slide 3 0 50 50 Slide 4 0 50 50 Slide 5 0 50 50 Slide 6 2 48 50 Slide 7 0 50 50 Slide 8 0 50 50 Total 3 397 400 Point Count Summary Results Type of Asbestos: Chrysotile Percentage of Asbestos: 0.75% Analyzed By: Liz Dutton Reviewed by: Steve(Fanyao)Zhang,President 2 • • SEATTLE ASBESTOS TEST NVLAP Ambditabort Lab Codes Lynnwood Laboratory 19701 Scriber Latta Road.Sade 103, Bellevue Laboratory 12727 Narltlup Way,Site 1,Bellevue, Seattle Laboratory.4500 9th Ave.NE,Seale 300.Seale,WA 98105. Lynnwood,WA 98036,Tet:425.673.9850.Fax:425.673.9610 YIrr190005,Tet:425.861.1111,Fax:425.861.1118 TeL 206.633.1111,FaX 206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA1600/R-93/116 Attr1.: Mr.Herb Brod Client EHS International.Inc. : 13228 NE 20th St#100,Bellevue,WA 98005 .Jobe. 10527-01r setdet: 201310461 Date Received: 413/2013 Se pies Recd 20 Oate Analyzed: 4/10/2013 es FederalFWay High School-BlockProject Loc.: �— Analyzed by Sarah Huang/Liz VT,on Reviewed by. Steve jFanyaol ZFarng.Freadent Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fbrous Components % Non-asbestos Fibers 1 10527-B-01 1 Light gray soft None Filler, Binder 3 Cellulose material detected 1 Tan rubbery None Rubber/binder, 2 Cellulose 2 10527-B-02 material with paint detected Paint Creme None 2 Mastic/binder 2 Cellulose golored mastic detected 3 10527 B-03 1 White sandy/brittle None Sand, Filler, 3 Cellulose material with paint detected Binder, Paint 4 10527-6-04 1 White sandy/brittle None Sand, Filler, 2 Cellulose material with paint detected Binder, Paint 5 10527-B-05 1 White sandy/brittle None Sand, Filler, 3 Cellulose with paint detected Binder, Paint 1 Light gray tile None Vinyl/binder, 2 Cellulose detected Mineral grains 6 10527-B-06 2 Yellow mastic de�teected Mastic/binder 3 Cellulose 3 Gray brittle None Binder 4 Cellulose material detected TanMlhite fibrous None 1 Binder, Paint 67 Cellulose 7 10527-6-07 with paint detected one 2 Black soft material deteed Binder 3 Glass fibers 1 Blue Tile None Vnyl/binder, 2 Cellulose detected Mineral grains 8 10527-6-08 2 Yellow mastic No entected Mastic/binder 3 Cellulose 3 Black mastic None Mastic/binder 3 Cellulose detected 9 10527-B-09 1 Gray brittle None Filler, Binder, Paint 2 Cellulose material with paint detected White brittle None 1 Filler, Binder, Paint 3 Cellulose 10 10527-B-10 material with paint detected 2 White chalky None Binder/filler, 25 Cellulose material with paper detected Gypsum/binder White brittle None 1 Filler, Binder, Paint 5 Cellulose 11 10527-B-11 material with paint detected 2 White chalky None Binder/filler, 36 Cellulose material with paper detected Gypsum/binder White brittle None 1 Filler, Binder, Paint 4 Cellulose 12 10527-B-12 material with paint detected 2 White chalky None Binder/filler, 35 Cellulose material with paper detected Gypsum/binder White brittle None 1 Filler, Binder, Paint 7 Cellulose 13 10527-B-13 material with paint detected 2 White chalky None Binder/filler, 23 Cellulose material with paper detected Gypsum/binder White brittle None 14 10527-B-14 1 Filler, Binder, Paint 2 Cellulose material with paint detected 1 II • SEATTLE ASBESTt -EST Lynnwood Laboratory'19791 Scriber Lake Road.Suite 103. Bellevue Laboratory:12727 Norttup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE.Suite 300.Seattle,WA 98105, Ly!nwwd,WA 98036,Td:425.673.9850.Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel'206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PIM by Method EPA/600/R-93/116 Aekc Mr.Herb Brad client EHS International,Inc Address: 13228 NE 20th St#100,Bellevue,WA 98005 Joblk 10527-01r Batt* 201310461 Date Received: 4/3/2013 Samples Recd: 20 Date Analyze& 4/10/2013 Samples Analyzed: 20 Protect Loc. Federal Way High School-Block .„.„---.=: ...' B Analyzed by: Sarah Huang/Liz Dub. Reviewed by. Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 2 White chalky None Binder/filler, 32 Cellulose material with paper detected Gypsum/binder 15 10527-B-15 1 Gray fibrous None Paint, Filler, Perlite 65 Cellulose material with paint detected 1 Gray fibrous None Paint, Filler, Perlite 65 Cellulose 16 10527-B-16 material with paint detected None 2 Brown masticected Mastic/binder 2 Cellulose, 1 Red ceramic None Ceramic/Binder None detected 17 10527-8-17 quarry Tile detected 2 Gray brittle/sandy None Binder, Sand 2 Cellulose material detected 18 10527-B-18 1 Black soft material None Binder, Paint 2 Cellulose with paint detected 1 Brown fibrous None Filler, Paint 90 Cellulose material with paint detected 19 10527-8-19 2 Brown mastic d e�ted Mastic/binder 3 Cellulose 3 Tan fibrous None Filler, Binder 65 Cellulose material detected Gray fibrous None 1 material with paint detected Paint, Filler, Perlite 65 Cellulose 20 10527-B-20 White Plastic None 2 material detected Plastic None detected 2 • • . • Iv- SEATTLE SEATTLE ASBESTOS TEST NVLAP Accradttation Lab Codes: 200876,Lynnwood-200768 Lynnwood Laboratory:19701 Satter Lake Road,Suite 103, 6e8evue Laboratory:12727 Nordntp hey,Stite 1.Bellevue, Seattle Laboratory:4500 91h Ave.NE,Suite 300,Seattle,WA 9810.5. Lynnwood,WA 98036.Tel:425.673.9850,Fax 425.673.9810 WA 96005.TeL 425.861.1111.Fax 425.861.1118 Tel:206.633.1111,Far 206.633.4747 ANALYTICAL LABORATORY REPORT PIM by Method EPA/600IR-931116 Am>.: Mr.Herb Brod dent: EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job#: 1 0527-01 r Barth. 201310529 Data Receive& 4/5/2013 Samples Redd: 13 Date Anayaed: 4/12/2013 �- —es - 13 Federal Way High School-BlockProiect Loc.: ` B Araiyzed by: di.mithh Reviewed by: Steve(Fanyao)7hang,Pres4wt Lab ID Client Sample ID Layer Description •• ,•:Fibers Non-fibrous Components % Non-asbestos Fibers Black soft/elastic None 1 Binder, Filler 2 Cellulose 1 10527-B-21 material detected 1 White soft/elastic None Binder, Filler, Paint 4 Cellulose material with paint detected 1 Gray soft/elastic None Binder, Filler 2 Cellulose 2 10527-B-22 material with paint detected _ 1 Silver soft/elastic None Binder, Filler 4 Cellulose material detected 1 Cream rubbery None Rubber/binder 2 Cellulose material detected _ 2 Cream mastic de emoted Mastic/binder 3 Cellulose 3 10527-B-23 White powdery None 3 material with paint detected Binder/filler, Paint 4 Cellulose 4 White chalky None Binder/filler, 21 Cellulose material with paper detected Gypsum/binder 4 10527-B-24 1 Gray brittle 3 Chrysotile Filler, Binder, Paint 2 Cellulose material with paint 1 Tan rubbery None Rubber/binder 2 Cellulose material detected 5 10527-B-25 2 Cream mastic None Mastic/binder 3 Cellulose detected 3 Brown mastic 3 Chrysotile Mastic/binder 5 Cellulose White brittle None 1 Filler, Binder, Paint 3 Cellulose 6 10527-B-26 material with paint detected 2 White chalky None Binder/filler, 21 Cellulose, material with paper detected Gypsum/binder Glass fibers White brittle None 1 Filler, Binder, Paint 4 Cellulose 7 10527-8-27 material with paint detected 2 White chalky None Binder/filler, 25 Cellulose, material with paper detected Gypsum/binder Glass fibers_ White brittle None 1 Filler, Binder, Paint 3 Cellulose 8 10527-B-28 material with paint detected White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 26 Glass fibers_ Yellow/tan soft None 9 10527-B-29 1 material with detected Filler, Binder 7 Cellulose,Talc fibrous material White chalky Binder/filler, 10 10527-B-30 1 material with paint None Gypsum/binder, 32 Cellulose, and paper detected Paint Glass fibers 11 10527 B-31 1 Brown mastic with None Mastic/binder, 24 Cellulose fibrous material detected Filler 12 10527-B-32 1 Gray brittle 3 Chrysotile Filler, Binder, Paint 3 Cellulose material with paint 13 10527-B-33 1 Black soft rubbery None Rubber/binder 2 Cellulose material detected 1 . • • ASBESTOS TEST N'/LAP A^w^"edit 7th tt Lab'odes:Bellevue-200876,Lynnwood-200765 Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103. Bellevue Laboratory:12727 Northup Way,Suite 1,Bellows, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel:206.833.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Mn.: Mr.Herb Brod cllent EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 .lab#: 10527-01r Batch# 201310528 Date Received: 4/5/2013 Samples Recd: 127 Date Analyzed: 4/11/2013 Samples Analyzed: 127 Federal Way High School-Block yrs w! Project Loc.: C j Analyzed by. RyaC Antolodc Reviewed by: Steve(Fanyao)Zhang.President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 1 Gray soft/elastic None Binder, Filler 4 Cellulose material detected 1 10527-C-01 Black foamy None Synthetic foam, 2 material with paint detected Paint, 3 Cellulose and mastic Mastic/binder 1 Black soft/elastic None Binder, Filler, Paint 4 Cellulose 2 10527-C-02 material with paint detected 2 Brown wood debris None Wood debris 6 Cellulose detected Black rubbery None Rubber/binder 2 Cellulose 1 material detected 3 10527-C-03 Cream mastic with None Mastic/binder, 2 4 Cellulose trace wood debris detected Wood debris Black soft/loose Filler, Fine 4 10527-C-04 1 material 3 Chrysotile particles 5 Cellulose None Vinyl/binder, 2 Cellulose 1 Off-white tile detected Mineral grains 5 10527-C-05 2 Yellow mastic de®t ectad Mastic/binder 4 Cellulose 3 Gray brittle None Filler, Binder, Sand 3 Cellulose material detected Gray foamy None Synthetic foam, 1 material with2 Cellulose detected Mastic/binder 6 10527-C-06 mastic 2 Gray brittle None Filler, Binder, Sand 3 Cellulose material detected 7 10527-C-07 1 Gray fibrous None Paint, Filler, Perlite 67 Cellulose material with paint detected Brown fibrous None 1 material with trace detected Filler, Paint 88 CellUlose 8 10527-C-08 paint Brown mastic with None Mastic/binder, 2 23 Cellulose, Talc Filler paper detected 1 White powdery None Binder/filler, Paint 4 Cellulose 9 10527-C 09 material with paint detected 2 White chalky None Binder/filler, Cellulose, material with paper detectedypsu34 Gypsum/binder Glass fibers 1 White powdery None Binder/filler, Paint 5 Cellulose 10 10527 C-10 material with paint detected 2 White chalky None Binder/filler, 37 d Gsum/binder Cellulose, material with paper detecteypGlass fibers White powdery None 1 material with paint detected Binder/filler, Paint 36 Cellulose 11 10527-C-11 and paper 2 White chalky None Binder/filler, Cellulose, material with paper detectedypsum31 Gypsum/binder Glass fibers Brown fibrous None 1 Filler, Paint 89 Cellulose 12 10527-C-12 material with paint detected 2 Brown mastic None Mastic/binder 5 Cellulose, Talc detected 1 . . • r S Ark L<" ASEFSTOS t FST i i...: p,.«<iez tu:.<c:.l�-;J Ocijaz:BT?it^.°,fes..,-20075 L,;>.r1wt3 ,x.200`$0 Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, _ Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel 206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-931116 Mn.: Mr.Herb Brod Kent EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job#: 10527-01r Batddk. 201310528 Date Received: 415/2013 Samples Redd: 127 Date Anatyzed: 4/11/2013 Samples Anelymd: 127 Federal Way High School-Block „-�” I Project Loc.: C rtla;v 1 ' Reviewed by: Steve Fan ao Zhan President Analyzed by: Ryan Antotack ( Y ) 9• Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 3 White brittle None Filler, Binder, Paint 3 Cellulose material with paint detected 1 Beige powdery None Binder/filler, Paint 4 Cellulose material with paint detected 13 10527-C-13 Gray sandy/brittle None 2 material with detected Sand, Filler, Binder 6 Cellulose fibrous material _ 1 Beige powdery None Binder/filler, Paint 2 Cellulose material with paint detected Gray sandy/brittle None 14 10527-C-14 2 material with detected Sand, Filler, Binder 7 Cellulose fibrous material 3 White chalky None Binder/filler, 26 Cellulose d G material with paper detected Beige powdery None Binder/filler, Paint 2 Cellulose material with paint detected 15 10527-C-15 Gray sandy/brittle None 2 material with detected Sand, Filler, Binder 5 Cellulose fibrous material 1 White soft/elastic None Binder, Filler, Paint 2 Cellulose material with paint detected 16 10527-C-16 2 Silver foil None Foil/binder None detected detected _ 3 Gray fibrous None Filler, Perlite 62 Cellulose material detected 1 White sandy/brittle None Sand, Filler, 3 Cellulose 17 10527-C-17 material with paint detected Binder, Paint 2 White chalky None Binder/filler, 27 Cellulose material with paper detected Gypsum/binder 1 White sandy/brittle None Sand, Filler, 4 Cellulose 18 1 D527-C-18 material with paint detected Binder, Paint 2 White chalky None Binder/filler, 36 Gypsum/binder Cellulose, material with paper detectedypsum Glass fibers White sandy/brittle None Sand, Filler, 3 Cellulose 19 10527-C-19 material with paint detected Binder, Paint 2 White chalky None Binder/filler, 34 Cellulose, material with paper detected Gypsum/binder Glass fibers 1 Tan rubbery None Rubber/binder 2 Cellulose material detected 2 Cream mastic None Mastic/binder 3 Cellulose detected 20 10527-C-20 3 White sandy/brittle None Sand, Filler, 4 Cellulose d Bi material with paint detectender, Paint 4 White chalky None Binder/filler, 27 Cellulose material with paper detected Gypsum/binder Black foamy None Synthetic foam. 21 10527-C-21 1 material with2 Cellulose detected Mastic/binder mastic None Vinyl/binder, 3 Cellulose 22 10527-C-22 1 Gray tile detected Mineral grains 2 • • s • SEATTLE AS EST'OS TEST NvL,,p A c adiwation Lab Coles.SeIie?tu -2d 0a73, L ynreow3-200765 - Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861,1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Mn.: Mr.Herb Brod client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job#: 10527-01r Batch#: 201310528 Date Received: 4/5/2013 Samples Recd: 127 Dabs Analyzed: 4/11/2013 samples Analyzed: 127 Federal Way High School-Block , Project Loc.: C ...,-L.Jaj Analyzed by: RyPa`nrAntolock Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 2 Yellow mastic None Mastic/binder 4 Cellulose detected 3 Gray brittle None Filler, Binder, Sand 5 Cellulose material detected 4 Gray sandy/brittle None Sand, Filler, Binder 3 Cellulose material detected 1 ' Blue tile None Vinyl/binder, 2 Cellulose detected Mineral grains 23 10527-C-23 Yellow/black Mastic/binder, 2 mastic with brittle 3 Chrysotile Filler 4 Cellulose material 1 Yellow/tan mastic dentected Mastic/binder 3 Cellulose Gray brittle None 2 Filler, Binder 2 Cellulose 24 10527-C-24 material detected 3 Black tile 3 Chrysotile Vinyl/binder, 3 Cellulose Mineral grains 4 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose 1 Beige/green mastic None Mastic/binder, 5 Cellulose with brittle material detected Filler 2 Yellow mastic None Mastic/binder 4 Cellulose 25 10527-C-25 detected 3 Gray brittle Norte Filler, Binder 2 Cellulose material detected 4 Gray sandy/brittle None Sand, Filler, Binder 4 Cellulose material detected 1 Yellow mastic deteected Mastic/binder 3 Cellulose 26 10527-C-262 Gray brittle None Filler, Binder, Sand 5 Cellulose material detected 3 Black mastic 3 Chrysotile Mastic/binder 3 Cellulose 1 Gray ceramic None Ceramic/binder None detected detected one 2 Beige mastic dem Mastic/binder 4 Cellulose 27 10527-C-27 Light gray None 3 brittle/sandy detected Binder, Sand 2 Cellulose material Dark gray 4 sandy/brittle detected Sand, Filler, Binder 4 Cellulose material 1 White ceramic d�tBGt� Ceramic/binder None detected 28 10527-C-28 2 Beige mastic d eected Mastic/binder 3 Cellulose 3 White brittle/sandy None Binder, Sand 2 Cellulose material detected 3 • • •• SEATTLE A:B EkT(:)S TEST IWv � ^ � 'rt.1trt^7 Lab Codas:Beile4FS-20£874;Ljlnwood-2;0788 Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, - Lynnwood,WA 98036,Tel:425.673,9850,Fax:425.673,9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Ann.: Mr.Herb Brod Client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Jobit: 10527-01r Batch* 201310528 Date Rees ved: 4/5/2013 Samples Redd: 127 Date Analyzed: 4/11/2013 samples Analyzed: 127 Federal Way High School-Block /1 ` Project Loc.: C �yyt.L"�v'r," Analyzed by. Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers Trace white None 4 powdery material detected Binder/filler, Paint 5 Cellulose with paint 1 Beige/yellow mastic None Mastic/binder 3 Cellulose detected None Vinyl/binder, 2 Cellulose 29 10527-C-29 2 Off-white tile detected Mineral grains 3 Black mastic with 3 Chrysotile Mastic/binder 4 Cellulose brittle material 1 Gray/beige sheet None Vinyl/binder None detected vinyl detected Brown fibrous None Binder/filler, 2 backing withdetected Mastic/binder 69 Cellulose 30 10527-C-30 mastic 3 Brown brittle None Filler, Binder 4 Cellulose material detected 4 Trace black mastic 3 Chrysotile Mastic/binder 3 Cellulose None Paint, Filler 2 Cellulose 1 Silver paint detected 31 10527-C-31 Gray/green None 2 soft/elastic detected Binder, Filler 3 Cellulose material 1 White soft/elastic None Binder, Filler 4 Cellulose material detected 32 10527-C-32 Trace gray/green None 2 soft/elastic detected Binder, Filler 2 Cellulose material 33 10527-C-33 1 Black soft/elastic None Binder, Filler 3 Cellulose material detected Brown fibrous None 1 Filler, Paint 91 Cellulose 34 10527-C-34 material with paint detected 2 Brown mastic NOS Mastic/binder 6 Cellulose, Talc detected Blue woven fibrous None 1 Filler, Binder 84 Synthetic fibers material detected None 2 Yellow/brown masti detected Mastic/binder 3 Cellulose 35 10527-C-35 Gray brittle None 3material detected Filler, Binder, Sand 4 Cellulose 4 Black mastic with 3 Chrysotile Mastic/binder 3 Cellulose brittle material - 1 Yellow/tan mastic None detected Mastic/binder 4 Cellulose Gray brittle None 2 Filler, Binder 3 Cellulose 36 10527-C-36 material detected 3 Black tile 3 Chrysotile Vinyl/binder, 2 Cellulose Mineral grains 4 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose 4 r r • • SEATTLE ASBESTOS TEST NV!.AP Accred toucan Lab Codes:Seltevue-200376,Lynnwood-200768 Lynnwood Laboratory,19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory 4500 9th Ave.NE.Suite 300,Seattle,WA 98105, Lynnwood,WA 98036,Tel.425.673.9850,Fax 425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel.206.633.1111.Fax 206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/12-93/116 Mn.: Mr.Herb Brod client: EHS International,Inc. Address: 13228 NE 20th St#100.Bellevue,WA 98005 Job 10527-01r Batch#: 201310528 Date Received: 4/5/2013 Samples Redd: 127 Date Analyzed: 4111/2013 Samples Analyzed: 127 Federal Way High School-Block 2 :" y' Project Loc.: C /�J=qyr(::‘ ,6" /.�.GY Analyzed by. ♦cyan Antelocck,_ Reviewed by Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 1 Beige powdery None Binder/filler, Paint 3 Cellulose material with paint detected 37 10527-C-37 Gray sandy/brittle None 2 material with detected Sand, Filler, Binder 5 Cellulose fibrous material 1 Beige powdery None Binder/filler, Paint 4 Cellulose material with paint detected 38 10527-C-38 Gray sandy/brittle None 2 material with detected Sand, Filler, Binder 7 Cellulose fibrous material 1 Beige powdery None Binder/filler, Paint 3 Cellulose material with paint detected 39 10527-C-39 Gray sandy/brittle None 2 material with detected Sand, Filler, Binder 6 Cellulose fibrous material Yellow fibrous None 1 Filler, Glass beads 93 Glass fibers 40 10527-0-40 material detected 2 Yellow/tan mastic None Mastic/binder 3 Cellulose detected 1 Orange/yellow shee None Vinyl/binder None detected vinyl detected Trace None Mastic/binder 2 Cellulose 41 10527-C-41 2 yellow mastic detected 3 Gray brittle None Filler, Binder, Sand 4 Cellulose material detected 4 Trace black mastic 3 Chrysotile Mastic/binder 3 Cellulose Tan soft material None Filler, Binder, Fine 42 10527-C-42 1 with fibrous detected particles, Debris 5 Cellulose material and debris 1 Tan/gray fibrous None Filler 84 Cellulose 43 10527-C-43 material detected 2 Brown mastic None Mastic/binder 7 Cellulose, Talc detected 1 Blue rubbery None Rubber/binder 2 Cellulose material detected 2 Brown mastic None Mastic/binder 3 Cellulose 44 10527-C-44 detected 3 Beige mastic None Mastic/binder 2 Cellulose detected 4 Brown wood debris None Wood debris 6 Cellulose detected 1 Blue rubbery None Rubber/binder 2 Cellulose material detected one 45 10527-C-45 2 Yellow mastic d � Mastic/binder 3 Cellulose 3 etect White powdery None Binder/filler, Paint 5 Cellulose material with paint detected 46 10527-C-46 1 Beige powdery None Binder/filler, Paint 3 Cellulose material with paint detected 5 • • > SENITLE ASBESTOS T LEST `LA' Accreditation+_ab C,des:Be.!evu 200876,Lynnwood-200768 Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 96105, ` Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax 425.861.1118 Tel 206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPN600/R-93/116 Ann.: Mr.Herb Brod Chant: EHS International,Inc. Address: 13228 NE 20th St*100,Bellevue,WA 98005 Job#: 10527-01r Batch* 201310528 Date Received: 4/5/2013 Samples Redd: 127 Data Andned: 4/11/2013 sa rples Analyzed: 127 Project Loc.: Federal Way High School-Block "7,?,', /72/, . �'. Analyzed by. Ryan Antotock Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers Gray sandy/brittle 2 material with deed Sand, Filler, Binder 6 Cellulose fibrous material 1 Beige powdery None Binder/filler, Paint 2 Cellulose material with paint detected 47 10527-C-47 Gray sandy/brittle None 2 material with detected Sand, Filler, Binder 7 Cellulose fibrous material 1 Beige powdery None Binder/filler, Paint 3 Cellulose material with paint detected 48 10527-C-48 Gray sandy/brittle None 2 material with detected Sand, Filler, Binder 5 Cellulose fibrous material White sandy/brittle None Sand, Filler, 1 4 Cellulose 49 10527-C-49 material with paint detected Binder, Paint White chalky None Binder/filler, Cellulose, 2 material with paper, detected Gypsum/binder 35 Glass fibers 1 White sandy/brittle None Sand, Filler, 3 Cellulose 50 10527-C-50 material with paint detected Binder, Paint White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 38 Glass fibers White sandy/brittle 1 material with paint None Sand, Filler, 34 Cellulose, 51 10527-C-51 and woven fibrous detected Binder, Paint Glass fibers material 2 White chalky None Binder/filler, 39 Cellulose, material with paper detected Gypsum/binder Glass fibers 1 White sandy/brittle None Sand, Filler, 2 Cellulose 52 10527-C-52 material with paint detected Binder, Paint White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 41 Glass fibers Brown chalky Binder/filler, 53 10527-C-53 1 material with paint None Gypsum/binder, 42 Cellulose, and paper detected Paint Glass fibers 1 Off-white powdery None Binder/filler, Paint 5 Cellulose 54 10527-C-54 material with paint detected 2 White chalky None Binder/filler, 34 Cellulose, material with paper detected Gypsum/binder Glass fibers White chalky Binder/filler, 55 10527-C-55 1 material with paint None Gypsum/binder, 37 Cellulose, and paper detected Paint Glass fibers 1 Off-white powdery None Binder/filler, Paint 5 Cellulose 56 10527-C-56 material with paint detected Brown chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 38 Glass fibers Brown chalky Binder/filler, None Cellulose, 57 10527-C-57 1 material with paint detected Gypsum/binder, 40 Glass fibers and paper Paint 58 10527-C-58 1 White powdery None Binder/filler, Paint 4 Cellulose material with paint detected 6 . , • • SEATTLE::ASBESTOS TEST P:ALAE k.,cTra,di,._ti:rt Lab Cedes:Be levee-200976,Lynnwood-200763 Lynnwood Labo atoyy 19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax 425.861.1118 Tel:206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Attn.: Mr.Herb Brod cur* EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Jobe: 10527-01r Batdr#: 201310528 Date Received: 4/5/2013 Samples Recd: 127 Date Analyzed: 4/11/2013 samples Analyzed: 127 Federal Way High School-Block /f %)�j- Project Lod.: C /: �{'6'�` Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Znang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers White chalky None Binder/filler, Cellulose, 2 material with paper detected Gypsum/binder 36 Glass fibers 1 Tan/brown soft/elas None Binder, Filler 3 Cellulose material detected 59 10527-C-59 Black soft/elastic None Cellulose, 2 material with detected Binder, Filler 7 Synthetic fibers fibrous material Off-white powdery None 60 10527-C-60 1 material with paint detected Binder/filler, Paint 3 Cellulose Blue powdery None Filler, Fine 61 10527-C-61 1 material with detected particles 62 Synthetic fibers fibrous material Blue powdery None Filler, Fine 62 10527-C-62 1 material with detected particles 64 Synthetic fibers fibrous material Blue powdery None Filler, Fine 63 10527-C-63 1 material with detected particles 60 Synthetic fibers fibrous material 1 White soft/elastic None Binder, Filler, Paint 4 Cellulose 64 10527-C-64 material with paint detected 2 Yellow fibrous None Filler, Glass beads 92 Glass fibers material detected Trace off-white None 65 10527-C-65 1 powdery material detected Binder/filler, Paint 3 Cellulose with paint Trace off-white None 66 10527-C-66 1 powdery material detected Binder/filler, Paint 2 Cellulose with paint , 67 10527-C-67 1 Gray fibrous None Paint, Filler, Perlite 65 Cellulose material with paint detected Brown fibrous 1 material with trace detected Filler, Paint 86 Cellulose paint 68 10527-C-68 2 Brown mastic None Mastic/binder 6 Cellulose,Talc detected 3 White chalky None Binder/filler, 24 Cellulose material with paper detected Gypsum/binder 1 Beige powdery None Binder/filler, Paint 3 Cellulose material with paint detected Gray sandy/brittle None 69 10527-C-69 2 material with detected Sand, Filler, Binder 6 Cellulose fibrous material 3 White chalky None Binder/filler, 24 Cellulose material with paper detected _Gypsum/binder 1 Beige powdery None Binder/filler, Paint 2 Cellulose material with paint detected 70 10527-C-70 Gray sandy/brittle 2 material with None Sand, Filler, Binder 5 Cellulose fibrous material 7 • • SEATTLE ASBESTOS F:Oa r ST Nvi..'kP. ,c,e t rtlon Lab Codes:Bellevue-200876,Lywrood-2007€18 Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103. Bellevue Laboratory:12727 Northup Way.Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, Lynnwood,WA 98036,Tel:425.673.9850,Fax:425,673.9810 WA 98005,Tel:425.861.1111,Fax 425.861.1118 Tel:206.633.1111,Fax 206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPN600/R-93/116 Ann.: Mr.Herb Brod client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job# 10527-01r Batch*. 201310528 Date Received: 4/5/2013 Samples Redd: 127 Date Analyzed: 4/11/2013 sample.Analyzed: 127 Federal Way High School-Block e"`/ l Project loc.: C Analyzed by: R jan Anlolock Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 1 White soft/elastic None Binder, Filler, Paint 2 Cellulose material with paint detected 71 10527-C-71 2 Silver foil None Foil/binder None detected detected 3 Gray fibrous None Filler, Perlite 63 Cellulose material detected 1 Brown rigid/brittle None Filler, Binder 2 Cellulose 72 10527-C-72 material detected 2 Gray sandy/brittle None Sand, Filler, Binder 3 Cellulose material detected 1 Gray sheet vinyl None Vinyl/binder None detected detected Gray fibrous None Binder/filler, 2 backing with detected Mastic/binder 68 Cellulose 73 10527-C-73 mastic 3 Black tile 3 Chrysotile Vinyl/binder, 3 Cellulose Mineral grains 4 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose 5 Brown wood block None Wood aggregates 5 Cellulose detected 1 Off-white/gray tile None Vinyl/binder, 2 Cellulose detected Mineral grains 2 Yellow mastic None to acted Mastic/binder 4 Cellulose 74 10527-C-74 Gray brittle None Filler, Sand, 3 material with detected Mastic/binder 5 Cellulose mastic 4 Black tile 3 Chrysotile Vinyl/binder, 2 Cellulose Mineral grains 5 Black mastic 3 Chrysotile Mastic/binder 3 Cellulose 1 Beige powdery None Binder/filler, Paint 2 Cellulose material with paint detected 75 10527-C-75 Gray sandy/brittle ^ None 2 material with detected Sand, Filler, Binder 7 Cellulose fibrous material 76 10527-C-76 1 Yellow mastic with None Mastic/binder, 5 Cellulose brittle material detected Filler, Sand 1 Yellow mastic with None Mastic/binder, 6 Cellulose brittle material detected Filler, Sand 2 Red tile 3 Chrysotile Vinyl binder, 3 Cellulose 77 10527-C-77 Mineral grains 3 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose 4 Brown wood block None Wood aggregates 5 Cellulose detected Yellow mastic with None Mastic/binder, Cellulose, 78 10527-C-78 1 fibrous material detected Filler 7 Synthetic fibers 2 Gray brittle None Filler, Binder, 3 Cellulose material with paint detected Paint, Sand 8 . • • e,^. '1,�, T a; tA, s c� ES�+s`R S TEST VLAP Accr d t;.,ti<n Lab t tales: llevti e-M-73, ,it voc-2 D713 8 ter"rai3�. d `c.-,2 FA� ads��ie� ..6.. Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue Seattle 20Labb3 11 ,4500Fax:206 Ave.NE.Suite 300,Seattle,WA 98105, Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005.Tel:425.861.1111,Fax:425.861.1116 7 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Attn.: Mr.Herb Brod client: EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job#: 10527-01r aster* 201310528 Date Received: 4/5/2013 Samples Recd: 127 DateMalyzed: 4/11/2013 Samples Analyzed: 127 ProlectLoc.: Federal Way High School-Block - C " Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhan9,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 1 Yellow/brown None Mastic/binder 4 Cellulose mastic detected Black mastic with 2 Chrysotile Mastic/binder, 5 Cellulose 2 soft material Filler 3 Brown fibrous None Filler 86 Cellulose 79 10527-C-79 material detected 4 Clear/yellow brittle None Filler, Binder 2 Cellulose material detected 5 Brown wood block None Wood aggregates 5 Cellulose detected 6 Black asphaltic None Filler,Asphalt, 69 Cellulose fibrous material detected Binder Gray fibrous NoneFiller, Glass beads 72 Cellulose, 1 material detected Glass fibers 80 10527-C-80 None 2 Brown mastic detected Mastic/binder 6 Cellulose,Talc Beige powdery None Binder/filler, Paint 2 Cellulose 1 material with paint detected 81 10527-C-81 Gray sandy/brittle None 2 material detected Sand, Filler, Binder 3 Cellulose 1 Beige powdery None Binder/filler, Paint 2 Cellulose 82 10527-C-82 material with paint detected 2 Gray sandy/brittle None Sand, Filler, Binder 4 Cellulose material detected Beige powdery None Binder/filler, Paint 3 Cellulose 1 material with paint detected 83 10527-C-83 Gray sandy/brittle None 2 material with detected Sand, Filler, Binder 7 Cellulose fibrous material 10527-C-84 1 Off-white powdery 2 Chrysotile Binder/filler, Paint 4 Cellulose 84 material with paint Composite2 Brown chalky None Binder/filler, 36 Cellulose, result<1% material with paper Gypsum/binderdetected Glass fibers 85 10527-C-85 1 Brown chalky None Binder/filler, 34 Cellulose, material with paper Gypsum/binderdetected Glass fibers 1 White sandy/brittle None Sand, Filler,d BiPaint 3 Cellulose 86 10527-C-86 material with paint detectender, 2 White chalky None Binder/filler, 38 Gm/binder Cellulose, material with paper detectedypsuGlass fibers Off-white/white None 1 powdery material detected Binder/filler, Paint 5 Cellulose with paint 87 10527-C-87 White chalky Binder/filler, None Cellulose, 2 material with paint detected Gypsum/binder, 42 Glass fibers and paper Paint 1 Off-white powdery 2 Chrysotile Binder/filler, Paint 4 Cellulose material with paint 88 10527-C-88 White chalky None Binder/filler, 33 Gum/binder Cellulose, 2 material with paper detectedypsGlass fibers 9 • SEATTLE ASBESTOS TEST MILA9 AcCi ,di sSont Lab Codes:<siie a 200878,'ynnwoo. 2007€13 Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300.Seattle,WA 98105, Lynnwood,WA 98036,Tel:425.673.9850,Fax:425.673.9810 WA 98005,TeL 425.861.1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Amt.: Mr.Herb Brod client: EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Jobe: 10527-01r wad* 201310528 Date Received: 4/5/2013 Samples Rec'd: 127 Date Analyzed: 4/11/2013 Samples Analyzed: 127 Federal Way High School-Block . °�y�' - Project Loc.: c 17. /4,, X . Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 1 Tan rubbery None Rubber/binder 2 Cellulose material detected 2 Cream mastic det�ete'ed Mastic/binder 3 Cellulose 89 10527-C-89 White/off-white 3 powdery material None Binder/filler, Paint 37 Cellulose with paint and detected paper Asphalt/binder, Black asphaltic None Binder/filler, Fine 90 10527-C-90 1 fibrous material detected particles, Debris, 74 Cellulose with debris Sand Gray sandy/brittle 91 10527-C-91 1 material with None to ectad Sand, Filler, Binder 6 Cellulose fibrous material 1 Yellow/tan mastic None Mastic/binder 4 Cellulose 92 10527-C-92 detected 2 Brown fibrous None Filler 88 Cellulose material detected 93 10527-C-93 1 Gray soft/elastic None Binder, Filler 3 Cellulose material detected Gray/green None 94 10527-C-94 1 soft/elastic detected Binder, Filler 4 Cellulose material Gray fibrousFiller, Fine 95 10527-C-95 1 material ``6 Chrysotile particles 32 Cellulose 96 10527-C-96 1 Black asphaltic 5 Chrysotile Asphalt/binder 3 Cellulose material 97 10527-C-97 1 Black asphaltic None Filler,Asphalt, 67 Cellulose fibrous material detected Binder 98 '10527-C-98 1 Tan paper with None Filler, 71 Cellulose black mastic detected Asphaltic/binder 1 White woven None Binder/filler 82 Cellulose 99 10527-C-99 fibrous material detected Gray fibrous Filler, Fine 2 material 55 Chrysotile particles 36 Cellulose 100 10527-C-100 1 Gray fibrous None Paint, Filler, Perlite 69 Cellulose material with paint detected 1 Brown fibrous None Filler, Paint 92 Cellulose material with paint detected 101 10527-C-101 2 Brown/black None Mastic/binder 7 Cellulose,Talc mastic detected 3 White chalky None Binder/filler, 24 Cellulose material with paper detected Gypsum/binder White chalky None Binder/filler, 102 10527-C-102 1 material with paint detected Gypsum/binder, 35 Cellulose and paper Paint 103 10527-C-103 1 Yellow mastic detected Mastic/binder 3 Cellulose 10 • • • 3 F^g'-'^,�' '!fi�xx TE T NVLAPA crttiSdY?LbCd ,-z�.;i�=`9t48.20i:8 b Y•ii`9oCd-2 ' B Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Nortttup Way.Suite 1,Bellevue Seattle Laboratory 4500 9th Ave NE,Suite 300,Seattle,WA 98105. Lynnwood,`NA 98036,Tel 425.673.9850,Fax:425.673.9810 WA 90005,Tel 425.861.1111,Fax:425.661.1118 Tel 206 633 1111 Fax 206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Amt: Mr.Herb Brod talentEHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job*: 10527-01 r Batch*. 201310528 Date Received: 415/2013 Samples Recd: 127Date analyzed: 4/11/2013 samples Analyzed: 127 Federal Way High School-Block Project Loc.: • f,. Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Descri• ption % Asbestos Fibers Non-fibrous Components % Non asbestos Fibers 2 Gray the 2 Chrysotile Vinyl/binder, 2 Cellulose Mineral grains 3 Black mastic 2 Chrysotile Mastic/binder 4Cellulose 4 Brown wood debris None Wood debris 7Cellulose detected Yellow/black None 1 Mastic/binder 4 Cellulose 104 10527-C-104 mastic detected None 2 Brown wood debris detected Wood debris 6 Cellulose 1 Gray rubbery None Rubber/binder 2Cellulose material detected 105 10527-C-105 2 Cream mastic detected Mastidbinder 3 Cellulose Brown mastic with None Mastic/binder, 27 Cellulose,Talc paint and paper detected Filler, Paint White chalky None Binder/filler, Cellulose, 106 10527-C-106 1 material with paint detected Gypsum/binder, 38 Glass fibers andpaper Paint 1 White sandy/brittle None Sand, Filler, 4 Cellulose 107 10527-C-107 material with paint detected Binder, Paint 2 White chalky None Binder/filler, 36 Cellulose, material with paper detected Gypsum/binder Glass fibers 10527-C-108 1 Off-white powdery 2 Chrysotile Binder/filler, Paint 5 Cellulose 108 material with paint Composite2 White chalky None Binder/filler, 27 Cellulose result<1% material with paper detected Gpsum/binder 1 Tan rubbery None Rubber/binder 2 Cellulose 109 10527-C-109 material detected Brown mastic with None 2 Mastic/binder 26 Cellulose,Talc paint and paper detected 1 White powdery None Binder/filler, Paint 5 Cellulose 110 10527-C-110 material with paint detected 2 White/pink chalky None Binder/filler, 34 Cellulose, material with paper detected Gypsum/binder Glass fibers White chalky None Binder/filler, Cellulose, 111 10527-C-111 1 material with paint detected Gypsum/binder, 40 Glass fibers and paper Paint White sandy/brittle 1 material with paint None Sand, Filler, 26 Cellulose, 112 10527-C 112 and woven fibrous detected Binder, Paint Glass fibers material 2 White chalky None Binder/filler, 32 Cellulose, material with paper detected Gypsum/binder Glass fibers Trace white None 1 powdery material detected Binder/filler, Paint 3 Cellulose with paint 113 10527-C-1132 White sandy/brittle None Sand, Filler, Binder 4 Cellulose material detected White chalky None Binder/filler, 37 Cellulose, material with paper detected Gypsum/binder Glass fibers 11 • SEATTLE ASBESTOS TEST MILAP Accreditation Lail Codes.Be Levu&200876,Lynnwood-200768 Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:4500 9th Ave.NE,Suite 300,Seattle,WA 98105, • Lynnwood,WA 98036.Tel:425.673.9850,Fax:425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPN600/R-93/116 Attn.: Mr.Herb Brod orient: EHS International,Inc. Addresx 13228 NE 20th St#100,Bellevue,WA 98005 Job#: 10527-01r Batch#: 201310528 owe Received: 4/5/2013 Samples Recd: 127 Bate Analyzed: 4/11/2013 Samples Analyzed: 127 Federal Way High School-Block /'�, Project Loc.: C jrw(10t4"- Analyzed by: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 1 Brown fibrous None Filler, Paint 89 Cellulose material with paint detected 114 10527-C-114 2 Brown mastic None Mastic/binder 6 Cellulose,Talc detected 3 White chalky None Binder/filler, 35 Cellulose, material with paper detected Gypsum/binder Glass fibers 115 10527-C-115 1 Gray fibrous None Paint, Filler, Perlite 64 Cellulose material with paint detected 1 Gray sheet vinyl None Vinyl/binder None detected detected . Beige fibrous None Binder/filler, 116 10527-C-116 2 backing with detected Mastic/binder68 Cellulose mastic 3 Black mastic with None Mastic/binder, 6 Cellulose brittle material detected Sand 1 Off-white/gray tile None Vinyl/binder, 2 Cellulose detected Mineral grains 117 10527-C-117 2 Yellow mastic None Mastic/binder 3 Cellulose detected 3 Black mastic with 3 Chrysotile Mastidbinder, 8 Cellulose brittle material Filler, Sand 1 White sandy/brittle None Sand, Filler, 3 Cellulose 118 10527-C-118 material with paint detected Binder, Paint 2 White chalky None Binder/filler, 31 Cellulose, material with paper detected Gypsum/binder Glass fibers White powdery None 1 material with paint detected Binder/filler, Paint 34 Cellulose 119 10527-C-119 and paper 2 White chalky None Binder/filler, 37 Cellulose, material with paper detected Gypsum/binder Glass fibers White powdery None 1 Binder/filler, Paint 4 Cellulose 120 10527-C-120 material with paint detected 2 White chalky None Binder/filler, 36 Cellulose, material with paper detected Gypsum/binder Glass fibers Trace white None 1 powdery material Binder/filler, Paint 3 Cellulose with paint detected 121 10527-C-1212 Brown fibrous None Filler 91 Cellulose material detected 3 Brown mastic None Mastic/binder 7 Cellulose,Talc detected 1 Yellow mastic None Mastic/binder 3 Cellulose detected 122 10527-C-122 2 Off-white tile 2 Chrysotile Vinyl/binder, 2 Cellulose Mineral grains 3 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose 1 Yellow mastic None Mastic../binder 3 Cellulose 123 10527-C-123 detected 2 Gray brittle None Filler, Binder, Sand 5 Cellulose material detected 12 . 4 • . . AEST S sE a• Nvi,„„A,pAccreditation Lab Codes:BRs'Isa ut 200878,Lynnwood-200708 Lynnwood Laboratory:19701 Scriber Lake Road,Suite 103, Bellevue Laboratory:12727 Northup Way,Suite 1,Bellevue, Seattle Laboratory:45009th Ave.NE,Suite 300,Seattle,WA 98105, Lynnwood,WA 98036,Tel:425.673.9850,Fax 425.673.9810 WA 98005,Tel:425.861.1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-93/116 Amt.: Mr.Herb Brod alene EHS International,Inc. Address: 13228 NE 20th St*100,Bellevue,WA 98005 Job#: 10527-01r Batch*: 201310528 Date Received: 4/5/2013 Samples Recd: 127 Date Analyzed: 4/11/2013Samples Analyzed: 127 Federal Way High School-Block 77X Proiect Loc.: C Analyzed by:RI(an Antolock Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 1 Yellow mastic None Mastic/binder 2 Cellulose detected 124 10527-C-124 2 Gray tile 3 Chrysotile Vinyl binder, 3 Cellulose Mineral grains 3 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose 1 Yellow mastic None Mastic/binder 2 Cellulose detected 125 10527-C-1252 Gray brittle None Filler, Binder, Sand 5 Cellulose material detected 3 Trace black mastic 3 Chrysotile Mastic/binder 3 Cellulose 126 10527-C-126 1 White soft/loose None Filler, Fine 6 Cellulose material detected particles 1 Yellow mastic None Mastic/binder 3 Cellulose detected 127 10527-C-127 2 Off-white tileNone Vinyl/binder, 2 Cellulose detected Mineral grains 3 Yellow mastic None Mastic/binder 4 Cellulose detected 13 • • SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Codes:200768 and 200876 19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,Te1:425.673.9850,Fax:425.673.9810 12727 Northup Way,Suite 1,Bellevue,WA 98005,Tel:425.861.1111,Fax:425.861.111 B Website:www.seattleasbestostest.com,Email:admin@seattleasbestostestcom PLM by Point Count(400 Points) Client Job#: 10527-01r Attention: Mr.Herb Brod Laboratory Batch#: 201310868 Client: EHS International,Inc. Date Received: 4/22/2013 Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 3 Date Analyzed: 4/2412013 Project: Federal Way High School-Block G Sample Requested for Point Count 10527-C-84 Previous Analytical Information Previously Analyzed by: Ryan Antolock Previous Batch#: 201310528 Previous Lab ID: 84 Previous Description: Off-white powdery material with paint Layer to be Point Counted: 1 Asbestos Type Found: Chrysotile Asbestos Percentage Found: 2 Point Count Analytical Procedures New Lab ID: 1 Asbestos Points Non-Asbestos Points Total Points Counted Slide 1 0 50 50 Slide 2 0 50 50 Slide 3 0 50 50 Slide 4 0 50 50 Slide 5 0 50 50 Slide 6 1 49 50 Slide 7 0 50 50 Slide 8 0 50 50 Total 1 399 400 Point Count Summary Results Type of Asbestos: Chrysotile Percentage of Asbestos: 0.25% Analyzed y: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang, President 1 . . • • SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Codes:200768 and 200876 19711 Scriber Lake Road,Suite D.Lynnwood,WA 98036,Te1:425.673.9850,Fax:425.673.9810 12727 Northup Way,Suite 1,Bellevue,WA 98005,Te1:425.861.1111,Fax:425.861.1118 Website:www.seattleasbestostestcom,Email:admin@seattleasbestostest.com PLM by Point Count(400 Points) Client Job#: 10527-01 r Attention: Mr.Herb Brod Laboratory Batch#: 201310868 Client EHS International,Inc. Date Received: 4/22/2013 Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 3 Date Analyzed: 4/24/2013 Project: Federal Way High School-Block C Sample Requested for Point Count 10527-C-88 Previous Analytical Information Previously Analyzed by: Ryan Antolock Previous Batch#: 201310528 Previous Lab ID: 88 Previous Description: Off-white powdery material with paint Layer to be Point Counted: 1 Asbestos Type Found: Chrysotile Asbestos Percentage Found: 2 Point Count Analytical Procedures New Lab ID: 2 Asbestos Points Non-Asbestos Points Total Points Counted Slide 1 0 50 50 Slide 2 _ 0 50 50 Slide 3 0 50 50 Slide 4 0 50 50 Slide 5 1 49 50 Slide 6 0 50 50 Slide 7 0 50 50 Slide 8 1 49 50 Total 2 398 400 Point Count Summary Results Type of Asbestos: Chrysotile Percentage of Asbestos: 0.5% ' Analyzed By: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President 2 ! • SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Codes:200768 and 200876 19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,TeI:425.673.9850,Fax.425.673.9810 12727 Northup Way,Suite 1,Bellevue,WA 98005,Tel:425.861.1111,Fax:425.861.1118 Website:www.seattleasbestostestcom,Email:admin@seattleasbestostestcom PLM by Point Count(400 Points) Client Job#: 10527-01r Attention: Mr.Herb Brod Laboratory Batch#: 201310868 Client: EHS International,Inc. Date Received: 4/2212013 Address: 13228 NE 20th St#100,Bellevue,WA 98005 Samples Received: 3 Date Analyzed: 4/24/2013 Project: Federal Way High School-Block C Sample Requested for Point Count 10527-C-108 Previous Analytical Information Previously Analyzed by: Ryan Antolock Previous Batch#: 201310528 Previous Lab ID: 108 Previous Description: Off-white powdery material with paint Layer to be Point Counted: 1 Asbestos Type Found: Chrysotile Asbestos Percentage Found: 2 Point Count Analytical Procedures New Lab ID: 3 Asbestos Points Non-Asbestos Points Total Points Counted Slide 1 0 50 50 Slide 2 1 49 50 Slide 3 0 50 50 Slide 4 1 49 50 Slide 5 0 50 50 Slide 6 0 50 50 Slide 7 0 50 50 Slide 8 1 49 50 Total 3 397 400 Point Count Summary Results Type of Asbestos: Chrysotile Percentage of Asbestos: 0.75% Analyzed'By: Ryan Antolock Reviewed by: Steve(Fanyao)Zhang,President 3 • • SEATTLE ASBESTOS TEST Lab 200878,Lynnwood-2007f Lynwood Litman 19701 Salter Lees Rasa.Sole 103. Bellevue taccratory 12727 Nolan V18y.Sine 1.Bellevue. Seattle Laboratory 4500 Sri Ave.NE.Sia 300,Swale,WA 96105. Lynwood,Vai 90036,1el;425..673.5650.Far 425.673.9810 WA.99005 Tei-425.861.1111,Far 425.861.1118 Td 206.633.1111,Far 206.633.4747 ANALYTICAL LABORATORY REPORT PEM by Method EPA/600/R-93/116 Ada.: Mr.Herb Brod alert EHS International,Inc. A63esc 13228 NE 20th St#100,Bellevue,WA 98005 ,Jobs: 10527-01r awe* 201310552 bate Receivat 4/8/2013 Samples Reda 45 Delo Analyzed 4/12/2013 SamplesAndyad: 45 n- Federal Way High School,Block f -�-_ '—._ _——"___„ Analyzed ty Liz Dutton Reveew e8 5r Steve(Farryae}Zr,a'g,P-eadeaa Lab ID Client Sample€D Layer Description % Asbestos Fters Non-librous Components 96 Non-asbestos Fibers 1 Tan rubbery None Rubber/binder 2 Cellulose material detected one 1 10527-D-01 2 Tan mastic d ed Mastic/binder 3 Cellulose None 3 Brown mastic Mastic/binder 5 Talc, Cellulose 1 Blue woven fibrous None Filler. Binder 85 Synthetic fibers material detected None 2 10527-D-02 2 Yellow/tan masticdetectedMastic/binder 4 Cellulose 3 Black mastic 3 Chrysotile Mastic/binder 6 Cellulose Tan fibrous one 1 material with white d Paint, Filler 92 Cellulose etected paint 3 10527-D-03 2 Dark brown mastic detected Mastic/binder 3 Cellulose, Talc 3 Pink chalky None Binder/filler, 25 Cellulose, material with paper detected Gypsum/binder Glass fibers 4 10527-D-04 1 White fibrous 65 Chrysotile Filler, Fine 25 Cellulose material particles None 1 Silver paint detectedPaint, Filler 4 Cellulose 5 10527-0-05 Blade asphaltic 1 materia! 5 Chrysotile Asphalt/binder 3 Cellulose 1 Blue woven fibrous None Filler, Binder 89 Synthetic fibers material detected on 6 10527-D-06 2 Yellow/tan mastic defecated Mastic/binder 3 Cellulose 3 Black mastic 3 Chrysotile Mastic/binder 5 Cellulose Gray None 1 material foamy detected Synthetic foam None detected e 2 Clear mastic de Mastic/binder 4 Cellulose 7 10527-D-073 Off-white/brown/ None Vinyl/binder, 2 Cellulose yellow/white tile detected Mineral grains 4 Yellow mastic Deeded Mastic/binder 4 Cellulose 5 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose 1 Trace blue woven None Filler, Binder 89 Synthetic fibers fibrous material detected None 8 10527-D-08 2 Yellow/tan mastic Mastic/binder 3 Cellulose ,detected 3 Black mastic 3 Chrysotile Mastic/binder 5 Cellulose 4 White brittle None Filler. Binder 3 Cellulose material Detected Green/gray soft None 9 10527-D-09 1 material detected Filler. Binder 3 Cellulose 1 • , r ei SEATTLE ASBESTOS TEST NVLAP Accreditation Lab 200878,Lynn Lynnwood laboratory:19701 Saiber Lake Road,Suite 103. Bellevue Laboratory:12727 Noilbup Way,Suite 1,Bdewe, Seattle Laboratory:4500 901 Ave.NE,Stile 300,Seattle.WA 98105, k Lynnwood,WA 98036,Tel:425.573.9850.Fax:425.673.9810 WA 98005.Tel:425.861.1111,Fax:425.861.1118 Tel:206.633.1111,Fax:206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA1600/R-937116 Aron: Mr.Herb Brod client EHS International,Inc. Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job*: 10527-01 r Bald*: 201310552 Date Received: 4/8/2013 Samples Recd 45 Date Anal md: 4/12/2013 sa 09lea Andyred: 45 Federal Way High School,Block ------��'��'__-.... — Project Loc.: D — . T� Analyzed by Liz Dutton Reviewed by: Steve(Fanyao)Zhang,President Lab ID Client Sample ID Layer Description % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers 10 10527-D-10 1 White soft/loose None Filler, Fine 7 Cellulose material detected particles Paint, Filler, Gray fibrous None Cellulose, 11 10527-D-11 1 material with paint detected Perlite, Glass 68 Glass fibers beads Tan fibrous 1 material with white None detected Paint, Filler 90 Cellulose paint 12 10527-D-12 2 Dark brown mastic None Mastic/binder 4 Cellulose, Talc detected White chalky None Binder/filler, Cellulose, 3 material with paper detected Gypsum/binder 21 Glass fibers 1 Gray brittle None Mastic/binder 4 Cellulose,Talc material detected Trace brown None 2 Mastic/binder 4 Cellulose, Talc mastic detected 13 10527-D-13 3 Orange mastic de Mastic/binder 4 Cellulose,Talc ted 4 Tan/white/brown tilE 2 Chrysotile Vinyl/binder, 2 Cellulose Mineral grains 5 Black mastic 3 Chrysotile Mastic/binder 4 Cellulose 1 Gray rubbery None Rubber/binder, 2 Cellulose material with paint detected Paint 14 10527-D-14 2 Creme mastic None Mastic/binder 3 Cellulose detected 3 Brown mastic dented Mastic/binder 5 Talc, Cellulose 1 Black rubbery None Rubber/binder, 2 Cellulose 15 10527-D-15 material with paint detected Paint 2 Creme mastic with None Mastic/binder, 29 Cellulose paint and paper detected Paint, Filler White chalky Binder/filler, 16 10527-D-16 1 material with paint None Gypsum/binder, 36 Cellulose, and paper detected Paint Glass fibers 1 White powdery None Binder/filler 5 Cellulose material detected 17 10527-D-17 White chalky Binder/filler, 2 material with paint None Gypsum/binder, 37 Cellulose, and paper detected Paint Glass fibers White powdery None 1 Binder/filler, Paint 3 Cellulose 18 10527-D-18 material with paint detected 2 White chalky None Binder/filler, 24 Cellulose, material with paper detected Gypsum/binder Glass fibers 10527-D-19 1 White powdery 2 Chrysotile Binder/filler, Paint 5 Cellulose 19 material with paint Composite2 White chalky None Binder/filler, 25 Cellulose, result<1% material with paper detected Gypsum/binder Glass fibers 2 • • a SEATTLE ASBESTOS TEST NVtAP Accr,: Lynnwood Laboratory 19701 Sather Lake Road Sudo 103. Betiewe Laboratory:12727 Nanbup Way,Sure 1,13dewe, Seattle Laboratory:4500 9th Ave.NE.Suite 300.Searde.'NA.98105. s Lynnwood,WA 98036,Tet:425.673.9850,Fax:425.6739810 WA 98006,Tet:425.861.1111,Fax 425.861.1118 Tet 206.6331111,Fax 206.633.4747 ANALYTICAL LABORATORY REPORT PLM by Method EPA/600/R-931116 Amt.: Mr.Herb Brod caent EHS International,Inc. Address: 13228 NE 20th St*100,Bellevue,WA 98005 Jotdi: 10527-01r 9atom 201310552 Date Received: 4/3/2013 Samples Redd: 45 Date analyzed: 4/12/2013 Samples Analyzed: 45 Project Loc.: Federal Way High School,Block _-----....) DCS�'} Analyzed by: Liz Dutton Reviewed by Steve Fanyao Mang.ores:dent Lab ID Client Sample IC) Layer Description % Asbestos Rows Non-fbrous Components % Non-asbestos Fibers Pink chalky Binder�ller, 20 10527-0-20 1 material with paint None Gypsum/binder, 35 Cellulose, and paper detected Paint Glass fibers White brittle None 1 Filler, Binder, Paint 2 Cellulose 21 10527-D-21 material with paint detected 2 White brittle None Sand, Filler. 4 Cellulose material with sand detected Binder, Perlite 1 White powdery 2 Chrysotile Binder/filler, Paint 5 Cellulose 22 10527-D-22 material with paint 2 Gray sandy/brittle None Sand, Filler. 3 Cellulose material with paint detected Binder, Paint 23 10527-D-23 1 Gray sandy/brittle None Sand, Filler, 3 Cellulose material with paint detected Binder, Paint 1 White powdery None Binder/filler, Paint 5 Cellulose 10527-0-24 material with paint detected 24 2 White powdery 2 Chrysotile Binder/filler, Paint 2 Cellulose material with paint Composite 3 Light pink chalky None Binder/filler, 24 Cellulose, result<1% material with paper detected Gypsum/binder Glass fibers 10527-0-25 1 White powdery 2 Chrysotile Binder/filler, Paint 5 Cellulose 25 material with paint Composite2 Light pink chalky None Binder/filler, 25 Cellulose, result<1% material with paper detected Gypsum/binder Glass fibers White chalky Binder/filler, None Cellulose, 26 10527-0-26 1 material with paint detected Gypsum/binder, 35 Glass fibers and paper Paint 1 Beige ceramic ducted Ceramic/binder None detected 2 White brittle None Binder 4 Cellulose 27 10527-0-27 material detected 3 Yellow mastic None Mastic/binder 5 Cellulose detected 4 White powdery 2 Chrysotile Binder/filler 3 Cellulose material Gray fibrous None Paint, Filler, Glass Glass fibers, 1 material with white detected beads 65 Cellulose paint 28 10527-0-28 2 Brown mastic duel Mastic/binder 3 Cellulose 3 White powdery None Binder/filler 35 Cellulose material with paper detected 4 White chalky None Binder/filler, 25 Cellulose material with paper detected Gypsum/binder 1 White powdery 2 Chrysotile Binder/filler 4 Cellulose material 29 10527-D-29 2 White paper None Binder/filler 79 Cellulose detected 3 White powdery 2 Chrysotile Binder/filler 34 Cellulose material with paper 3 • r • SEATTLE ASBESTOS TEST .abCodex Belevue400.76,Lynnwood-200M Lyrarwood Laboratory 19701 Saltier Lace Road,Stile 103, Be9evue Latxoratary,12727 Narttaxa Way,Suite 1,3caenue, Seattle Laboratory.4500 9th Ave.NE.Suite 300.Seattle,WA 98105, Lynnwood,WA 96035,Tat 425.673.9850,Fax 425.673.9810 WA 96005..Tet 425.861.1111,Fax 425.861.1118 Tet:2E6.833.1111,Far:206.633.4747 ANALYTICAL LABORATORY REPORT PIM by Method EPA/600/R-93/116 Ain: Mr.Herb Brod cunt EHS International.Inc. Address 13228 NE 20th St#100,Bellevue,WA 98005 Jobst: 10527-01r saat# 2 01 31 0552 Date Receivecd 4/8/2013 samples Reed: 45 Date Analyzed: 4/1212013 Senates Analyzed: 45 ProjectLam: Federal Way High School,Block by: icdLiz Neon Reviewed by Steve(Farryrao)Zhang,President Lab ID Client Sample ID Layer Desaiption % Asbestos Fibers Non-fibrous Components % Non-asbestos Fibers Composite White chalky None Binder/filler, result<1% 4 material with paper detected Gypsum/binder 25 Cellulose Gray fibrous None Paint, Filler, Glass Glass fibers, 1 material with white detected beads 65 Cellulose 30 10527-D-30 paint one 2 Brown mastic d Mastic/binder 3 Cellulose 1 etected Tan rubbery None Rubber/binder 4 Cellulose material detected 31 10527-0-31 2 Creme mastic detected Mastic/binder 3 Cellulose 3 Brown mastic dtteonded Mastic/binder 6 Talc, Cellulose 1 Blue woven fibrous None Filler, Binder 85 Synthetic fibers material detected 32 10527-0-32 2 Yellow mastic d�e eted Mastic/binder 7 Cellulose 3 Dark gray mastic deteonr ed Mastic/binder 5 Cellulose 1 Yellow mastic NdMastic/binder Mastic/binder 6 Cellulose White loose brittle None 2 Filler, Binder 7 Cellulose 33 10527-D-33 material detected Trace gray None 3 sandy/brittle Binder, Filler 5 Cellulose detected material None 1 Yellow mastic Mastic/binder 5 Cellulose detected one 34 10527-D-34 2 Dark gray mastic d Mastic/binder 4 Cellulose 3 etected Gray sandy/brittle None Binder, Filler 5 Cellulose material detected 1 Light gray rubbery None Rubber/binder, 2 Cellulose material with paint detected Paint Non35 10527-D-35 2 White mastic dtected Mastic/binder 2 Cellulose 3 White powdery None Binder/filler, Paint 3 Cellulose material with paint detected 1 Gray foamy None Synthetic foam None detected material detected 36 10527-D-36 2 Clear/yellow None Mastic/binder 4 Cellulose mastic detected 3 Black mastic 3 Chrysotile Mastic/binder 5 Cellulose 1 Black foamy None Synthetic foam None detected 37 10527-D-37 material detected 2 Beige mastic dad Mastic/binder 3 Cellulose 4 4, • S SEATTLE ASBESTOS TEST NVLAP Accreditation Lab Codes:l3 8,L. 2007 Lyrnaood Leaman:19701 Saber Lek Road Suds 103, BeIeaee Laboratory-12727 iior5a4 Way,Stole 1,Bele%ue, SeaNte Laboratory.4500901 Ave_NE,Sale 300,Seattle.We 96105, Lynwood,WA 98636,Td 425.673,9650,Far 425.6719810 WA 98005. el_425.851.1111,Fax 425.861.1118 7e1:205,633.1111,Fax 206.633,4747 ANALYTICAL LABORATORY REPORT PLM by Method EPAI600/R-93/11 s M: Mr.Herb Brod csent ENS International,Inc_ Address: 13228 NE 20th St#100,Bellevue,WA 98005 Job,: 10527-01r sestet 201310552 pee Received 4/8/2013 Samples Recd: 45 Daae autyeet 4/12/2013 Sernpiac Analyzed 45 Rcjxt Lac: Federal Way High School,Block __ X Analyzed by L b orison Reviewed by. Steve(Fanyao)Zana.1 resder9 Lab ID Client Sample ID Layer Description % Asbestos Fliers Non-fibrous Components % Non-asbestos Fibers White chalky None Binder/filler, Cellulose, 38 10527-D-38 1 material with paint detected Gypsum/binder. 32 Glass fibers and paper Paint White chalky! None Binder/filler, Cellulose, 39 10527-D-39 1 material with paint detected Gypsum/binder. 35 Glass fibers and paper Paint 1 White powdery None Binder/filler, Paint 4 Cellulose 40 10527-D40 material with paint detected 2 White chalky None Binder/filler, 23 Cellulose, material with paper detected Gypsum/binder Glass fibers 1 White powdery None Binder/filler, Paint 3 Cellulose 10527-D-41 material with paint detected 41 2 White powdery 2 Chrysotile Binder/filler, Paint 2 Cellulose material with paint Composite White chalky None Binder/filler, Cellulose, result<1% 3 material with paper detected Gypsum/binder 26 Glass fibers White powdery 1 material with paint Nde led Binder/filler, Paint 34 Cellulose 42 10527-D-42 and paper 2 White chalky None Binder/filler, Cellulose, material with paper detected Gypsum/binder 25 Glass fibers 43 10527-D d3 1 Black soft/loose Filler, Fine material 2 Chrysotile particles 5 Cellulose Black foamy None Synthetic foam, 44 10527-D-44 1 material with clear None detected mastic detected Mastic/binder 1 Gray soft/elastic Nolte Binder, Filler, Paint 4 Cellulose material with paint detected 45 10527-0-45 2 Red brittle material de Rtected Filler, Binder 2 Cellulose Trace gray on3 sandy/brittle deteected Sand, Filler, Binder 3 Cellulose material 5 • ! i e` b SEATTLE ASBESTOS TEST rdvLAP Accreditation Lab codes 2007&3 and 2036 75 19711 Scriber Lake Road,Suite D,Lynnwood,WA 98036,Te1:425.673.9850.Fax:425.673.9810 12727 Northup Way,Suite 1.Bellevue,WA 98005,TeL Fax:425.861.1118 Website:www.seattleasbestostest.com,Email:admin@seattleasbestostesLcom PLM by Point Count(400 Points) Client Job#: 10527-01r Laboratory Batch#: 201310973 Attention: Mr.Herb Brod Date Received: 4!25/2013 Client: EHS International,Inc. Samples Received: 1 Address: 13228 NE 20th St#100,Bellevue,WA 98005 Date Analyzed: 4/29/2013 Project Federal Way High School,Block D Sample Requested for Point Count 10527-D-19 Previous Analytical Information Previously Analyzed by: Liz Dutton Previous Batch#: 201310552 Previous Lab ID: 19 Previous Description: White powdery material with paint Layer to be Point Counted: 1 Asbestos Type Found: Chrysotile Asbestos Percentage Found: 2 Point Count Analytical Procedures New Lab ID: 1 Counted Asbestos Points Non-Asbestos Points Total Points50 Slide 1 0 50 50 50 Slide 2 0 50 Slide 3 0 50 Slide 4 0 50 5050 Slide 5 1 59 50 Slide 6 0 50 50 Slide 7 1 49 Slide 8 0 50 50400 Total , 2 398 Point Count Summary Results Type of Asbestos: Chrysotile Percentage of Asbestos: 0.5% Analyzed By: Liz Dutton Reviewed by: Steve(Fanyao)Zhang:President ;_--7-1.7-7:22_-_ ,..------ ---.. 1