Loading...
13-104298 _ s wilding = Single Family City of Federal Way Community&Econ.Dev.Services Permit #: 13-104298-00-SF 33325 8th Ave S ' Federal Way,WA 8003 Ph:(253)835-2607 Fax:(253)835-2609 Inspection Request Line: (253) 835-3050 Project Name: LORD'S JOY ADULT FAMILY HOME Project Address: 30440 11TH AVE S Parcel Number: 091900 0215 Project Description: ALT-Verification of Occupancy for Adult Family Home. ***No construction work allowed under this permit.*** Owner Applicant Contractor Lender BEVERLY A FIGUERAS MARIA LOURDES F BARTOLOME ROLAND R FIGUERAS LORD'S JOY ADULT FAMILY 30440 11TH AVE S HOME FEDERAL WAY WA 98003 3242 S 296TH PL AUBURN WA 98001 Census Category: 434 - Residential alt/add - no change in number of units Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area(sq.ft.) 0 0 0 0 Additional Permit Information New/Additional Sq.Feet- 1st Floor 0 New/Additional Sq.Feet-2nd Floor 0 New/Additional Sq.Feet-3rd Floor 0 New/Additional Sq.Feet-Basement 0 Basic Plan? No New/Additional Sq.Feet-Deck 0 New/Additional Sq.Feet-Garage 0 Mechanical to be Included? No New/Additional Sq.Feet-Other 0 Plumbing to be Included? No New/Additional Sq.Feet-Total 0 Zoning Designation RS 7.2 No Fixtures Associated With This Permit !! PERMIT EXPIRES Tuesday, March 25, 2014 Permit Issued on Thursday, September 26, 2013 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the - ill be in accordance with the laws, rules and regulations of the State of Washington • , prig ,- City of Federal Way. Owner or agent: Date: °//0 f12-0- FNP • it (AFH) LOCAL BUILDING INSPE N CHECKLIST • References:2012 IRC Section R325(WAC 51-51 SEP 2 V 2013 APPLICATION NIMABER: / 3 -s/C V S 5ff 0tiAmp 3RAMI MUST BE COMPLETED BY APPUCANT BEFORE INSPECTION WILL BE PROCESSED II SECTION 1 - PROPERTY INFORMATION SITE ADDRESS: 301#0 1 (' 4 T. l .L• (1V 4/ 9 ASSESSOR'S TAX/PARCEL# SECTION 2 -APPLICANT INFORMATION PROPERTY OWNER NAME: Bal-Y. RA DAYTIME PHONE: (o2`3-3) 610-91,0 AFH LICENSEE NAME(IF DIFFERENT): l [AiQ 4 '2D1S F, /3412-That ME PHONE: POO)�'/'. ��J- rSECTION 3 - FLOOR PLAN On a separate sheet of paper (81/i x 11) draw a floor plan (including all floors) of your prospective AFH. Include all sleeping rooms (bedrooms) indicating which bedroom is: A, B, C D, E and F. Label all components for exiting i.e., stairs, ramps, platforms, lifts and elevators. SECTION 4- DISCLAIMER/SIGNATURE BLOCK I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge, and that I am requesting or I am authorized by the owner of the above premises to request inspection for the operation of an Adult Family Home at this location. I agree In hold harmless the jurisdiction conducting sudr inspections, at my request, as to any daim n (including costs, expenses, and attorneys' fees incurred the investigation of such daim), which may be made by any person, i "" ► 1`lncluding the undersigned, and filed against the jurisdiction, but only where such claim arises out of the reliance cf the jurisdiction, including its % icers and employees, ••• 1 • accuracy of the information supplied to the jurisdiction as a part of this application. 4,46 Jo , NAMETTITLE: -'°Iu/4 DATE: 0° o2 •P r OPERTY OWNER O APPLICANTCEN SEE Effective:2013 July 01 Updated:2013 June GEN,ERALYES N�O� Bathroom doors are easily and quickly nable from the outside when locked 0 L7' ` Carbon Monoxide alarms are installed as required in R315.1 on each level of the home. 0 Smoke alarms are installed on all levels of the dwelling,in each resident sleeping room,outside each separate . sleeping area in the immediate vicinity of sleeping rooms(R314). GT 0 Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all d 0 parts of the dwelling upon activation of a single device. Access road and water supply meet local fire jurisdictional requirements. ite 0 R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). a ti Pocket doors shall have graspable hardware available when in the closed or open position. 0/ 0 R311.8 Ramps YES NO Inside Ramp N/A 0 0 R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) �/ R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes 0 directions. Ei o R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. LK Outside Ramp N/A 0 YESNO 8311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) a 0 8311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes F Ai 0 directions. R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. E21 0 w/ Guards below are depicted vertically as an example only.All Ramps must have Guards 0 Handrail both sides •- — Less than 4" 34"-38" Guard 36"min • 3'x 3'min landing 3'x 3'min landing N. 3' — One unit vertical in twelve units horizontal 3' ...- minimum minimum is an 8.3%slope all along surface of the ramp. minimum R311.2 Means of Egress YES NO R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. IV a R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 0 R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry 0 t without use of key,tool or s cial knowledge. Required exit door shall have no additional locking devices. R311.7 Stairways N/A I YES_ NO R311.7.4.1 Riser Height:Max riser height shall be 7 J inches(8 inches in structures built prior to July 1,2004) Al _C ..V R311.7.4.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built prior to July 1,2004) 0 0 R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple 0 0 risers.Handrails shall be installed in accordance with R311.7.7.1—R311.7.7.4 Effective:2013 July 01 Updated:2013 June , NAME OF AFH: Lords aru A EH- 0 ' SECTION 5 MUST BE COMPLETED BY THE BODING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. . PLEASE CHECK ALL APPLICABLE BOXES;MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN—USING THEIR PROSPECTIVE RESIDENT BEDROOM DESIGNATIONS OF A B C 0 E AND FAND CLASSIFICATION CODE S,NS1 OR NSZ. SECTION 5— BUILDING INSPECTOR'S INSPECTION CHECKLIST R325.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area. Type NS1—where 1 means of egress at grade level(has no stairs)or ramp constructed compliant with R325.9 is provided to evacuate residents to public area. Type NS2—where 2 means of egress at grade level(both have no stairs)or ramps constructed compliant with R325.9 are provided to evacuate residents to public area. SLEEPING ROOM A 0 Type S 0 Type NS1 0 Type NS2 YES NO )( Closet door/s are readily openable from the inside 0 Yes E:144o Smoke alarm is installed in the bedroom all/ 0 X Bedroom door opens easily and quickly from the outside when locked 0 Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) Er 0 EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"above floor;no steps under window permitted (e 0 SLEEPING ROOM B Type S 0 Type NS1 0 Type NS2 YES NO Closet door/s are readily openable from the inside 11Yes o Smoke alarm is installed in the bedroom (3',, 0 Bedroom door opens easily and quickly from the outside when locked Y Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 13 O EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"above floor;no steps under window permitted 0 SLEEPING ROOM C OType S OType NS1 OType NS2 YES NO Closet door/s are readily openable from the inside ('es 0 No ( Smoke alarm is installed in the bedroom gi 0 Bedroom door opens easily and quickly from the outside when locked 0 Se Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) EX 0 EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"above floor; no steps under window permitted 1 0 SLEEPING ROOM D 0 Type S 0 Type NSl 0 Type NS2 YES NO Closet door/s are readily openable from the inside 04es 0 No Smoke alarm is installed in the bedroom Er 0r Bedroom door opens easily and quickly from the outside when locked 0 LY Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) Cr0 EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF Sleeping room window has a maximum sill height of 44"above floor;no steps under window permitted i 0 SLEEPING ROOM E 0 Type S 0 Type NS1 0 Type NS2 YES NO C o oor/s are readily openable from the inside 0 Yes 0 No I Smoke alarm is installed in the bedroom 0 0 Bedroom do o ems easily and quickly from the outside when locked 0 13--- Sleeping Sleeping room window a t opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wi.- • 0 EXCEPT per R310.1.1:at-grade esca ' doves—may have net clearance openin: Sleeping room window has a maximum sill height . _.: • ': , . eps under window permitted 0 0 SLEEPING ROO V• • Type S 0 Type NS1 0 Type NS2 YES NO Closet door/s are readily opena. - om the inside 0 Yes 0 No oke alarm is installed in the bedroom 0 0 Bedroom door opens -- and quickly from the outside when locked 1_______ 0 0 Sleeping room ' ow has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least ide) 0 0 EXCEP .1.1:at-grade escape windows—may have net clearance opening 5 SF eeping room window has a maximum sill height of 44"above floor;no steps under window permitted 0 0 Effective: 2013 July 01 Updated:2013 June R325.8 Grab Bars in Bathrooms N/ / YES NO ` X Grab bars shall be installed for all water ciSsets(toilets),bathtubs and showers according to R325. . Q rar X Water Closets(toilet)shall have grab bars installed on both sides according to R325.8—R325.8.3.2. 0 Di N Bathtubs shall have two vertical and three horizontal grab bars installed according to R325.8—R325.8.2&R325.8.4—R325.8.4.2 0 • X Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower according to R325.8—R325.8.2& Q R325.8.5—R325.8.5.2. I Shower stalls must be minimum size of 30 inches deep by 48 inches long(R325.11) Q AG103—AG105 Swimming Pool,Spa,Hot Tub YES NO AF105.2 Must be surrounded by bar ier hat is 48 inches high,may have doors and or gates that must have audible alarms when o 0 opened. AG105.5 EXCEPTION:Pool as H ubs J4ith a safety cover which complies with ASTM F 1346—t— SED L ORRECTIONS REQUIRED 0 PERMIT REQUIRED &-F+ v- INSPECTOR'S NAME(PRINT) �-�— ( b 21 I 13 INSPECTOR'S SIGNATURE DATE: 33325 S z'—t' itIC . S • F 4e. ( W ck,y LA)15r qi�Ob 3 �(,• S 35- 'Z(v 2 INSPECTOR'S OFFICE ADDRESS J PHONE NUMBER: Application and inspection checklist developed by Washington Association of Building Officials(WABO),in cooperation with Department of Social and Health Services(DSHS)for use by both departments and licensors. 07/01/2013 Effective:2013 July 01 Updated:2013 June • • • • _ ___,....______ _ ___ 5____ LORD' . LORDS JOY Aril riz - i 1 -6 Sgrgol7- tegFire Daft2,M0 a$ i-00,4244#6, Entry Dam- 6y,,,,- ME-C-1 --16") Pt-A6E ltiA IF rillor 15 / J —Fi-f it1- 1 gia,w,..m,,,, ,isi-,-,-•,, 5n..2 DCCT . CZ.;AIl'e 1 7 ''''''''=''''''''''*. E .,: r, .:'. ---7 •W Yo i,.-J , ii A Patio . - ,...„ 1... , EX ' r I ) B AC c. f)LV,R, d : ft 4 V4.,',K,Zt k:-- Fare Place FUMaCe Ho Finer rant. 4i !- • . k _„. it I ! Shower I I/ --- , Ni lc ' -- - i D'' i 1 Family Room\ - ,' 1 WM \ t ''"',tedroorn 7..,, -c , taiga( -v- __ I' .•W '; Bath i Ai i= - i ' Room t Assia i ; 04. 53 sa Pr- ... , 1......„.......___,...„, 1., 1 i Kitchen 1 :8°' T Walk-in ,,--'" 0 Ron , : 5 1- „..,„,.....,_, ,, ,.., ....,_.7,---- i U it i g 1 I RR)! r'l-q 1 ! ? raining Room 111 1 . 4,........._________ , ,<1.-------- - "&13.-------- : 60 IN. 157g.Pr ! . `I. tI!f ..........._...,,,s..-•,-:--- G..:,.,.,.......k...,.ii4 . I...L___ td•.5. M'ILasg.._aV,.,.-..- '- C' Bed 3torn . - _ : . • ,. . • &1,(I.i16i1.,1.4.I ,'. -....2.1 ving .1 - ......._— Closet • I i Li _ tCLO.S'ET I • [WI- r!'ooi i ., - Closet rn 'e - - --lity,,,,IN i • 1 . / . - ,- I a.o-1/44- – ?, lift ,la . 1 RN%I 31? 1 @. -:) - 1 ....11- % ) i , cOs Bedroom - I 1;1-7-I i 1 A ' - IA fj :7 1 ite iit FT e:7! sta 0 1,';', I ,_. ! - 48_..J v g : 1, i i ; Fri.;ft 1--,,_.. ,rt...._. ....:...2......._____6:F11: ' ' ,..,..._. ..: 7 : i2P..; A_ U 1'74 1 ; .. t :. .:,_ v...W•---7 — . , _._ 0 - - L'I'''PrNi FET6-1 IQ 6 PtiPt4.0-E- I F - r L.kif46 :flax: IC A-T Tli-E B-.--AcK- - °F TI-K; HOU,Ce. T , 0. . M I NI,10 t)Or ,4.--- - :' .........==...a...4 ... . . .. _ .. I ----- ----....._ --!..--2-.7---, , , v (--, , A-- 1 , g24 'eel . ‘alt3 l' 1 . i . —......---1 e . ..... _ 1, C) ' ; ........ I I ' i . .. i — ''.--'— .1 r OE . I 0 .eZ 0 ...‹, r . 1 c 4.- ..,1,..‘') i 1 kI.....t.a............*m....1 . 1 1 E E 1 m's•Ip kCj F *3 r %--.7_, ........\..4 ......—• -..4 i — .. • iR i kivtc- 4777e, p-LeK PL' ........._______ CITY OF RECEIVE[. HERMIT *F- CO ME PL DE EN FP Federal Way COM53 8N 607•FAX DEVELOPMENT 5ERvI c E p 2 6 2 AP P LI CAT I O N 2609 u.,6.3.riQp2ty-rieraml:g com CITY OF FEDERAL.WAY CDS SITE ADDRESS SUITE/UNIT# 440 I I+` AVE YJ b. WAY , WA- q80a3 PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL# TYPE OF PERMIT BUILDING CIPLUMBING ElMECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT Le,, Vi y"t S J �i(Tenant Name/Homeowner Last Name) 1� I PROJECT DESCRIPTION p Detailed description of work to V ��{/ C f (j L � A r w 1-4 be included on this permit only NAME �— f�� � PRIMARY PHONE PROPERTY OWNER ��j/\`/ y /� FiQu�E ( 253 �. _ 9(i c� MAILINGADDRESS 494' !1 ve, S W� E-MAIL CITY STATE ZIP PO91r2- am-1 NAME PHONE ant- MAILING nLMAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONT CTOR'S LICENSE# EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE# NAME PHONE APPLICANT MAILING ADDRESS E-MAIL CITY STATE ZIP ZIP /� FAX PROJECT CONTACT �\ MAPA 1 C.t%��, i'�. rIR�W M� HONE,C nasi ��Zs (The individual to receive and �/,� MG ADDRESS respond to all correspondence E-MAIL rd # conceming this application) 3,24a S . a9Gff4 P © S j oy CITY STATE ZIP ad ecbto ALTERNATE CONTACT NAME: IFAX n ��PHONE E-MAIL" �• 5o 024; PROJECT FINANCING NAME U OWNER-FINANCED Required value of$5,000 or more (RCW 19.27.095) MAILING ADDRESS,CITY,ST , IP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner.I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct.I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim(including costs, expenses, and attorneys'fees incurred in the investigation and defense of such claim),which may be made by any person, including the undersigned, and filed against the city, but only where such claim • '.es out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to /as a p•rt of this application. h' / / ga SIGNATURE: y DATE PRINT NAME: i , . i. 410 ~ // , 111I:7!//IiiLL�/'� Bulletin#100-April 14,2110 Page 1 of 3 k:A1-Iandouts\Permit Application